Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
DESIGN GUIDE
1ISSUE DATE: 1-16-16 REVISION DATE:
URB
AN
3 S
TORY
- 64
UN
ITEX
TERI
OR
MISSOULA, MT
2ISSUE DATE: 1-16-16 REVISION DATE:
URB
AN
3 S
TORY
- 46
UN
ITEX
TERI
OR
JAMESTOWN, ND
3ISSUE DATE: 1-16-16 REVISION DATE:
URB
AN
4 S
TORY
- 63
UN
ITEX
TERI
OR
BROOKINGS, SD
4ISSUE DATE: 1-16-16 REVISION DATE:
CHA
LET
4 ST
ORY
- 63
UN
ITEX
TERI
OR
BEND, OR
5ISSUE DATE: 1-16-16 REVISION DATE:
URB
AN
3 S
TORY
RET
AIL
- 46
UN
ITEX
TERI
OR
ABERDEEN, SD
6ISSUE DATE: 1-16-16 REVISION DATE:
SITE
REN
DER
ING
EXTE
RIO
R
200’
±
7ISSUE DATE: 1-16-16 REVISION DATE:
GU
EST
ROO
MS
INTE
RIO
R
8ISSUE DATE: 1-16-16 REVISION DATE:
DESIGN GUIDE ROOM MIX
GUEST ROOMS 1 2 3 TOTALSFLOOR LEVEL
176’ 6.5”
68’ .
5”20
’
STUDIO QUEENSTUDIOACCESSIBLE STUDIO W/ ROLL IN SHOWERACCESSIBLE STUDIO
1010
1001
1000
3011
DOUBLE QUEENDOUBLEEXTENDED DOUBLEACCESSIBLE DOUBLE
700
921
1021
2642
ACCESSIBLE ROOMS W/ MOBILITY FEATURESROOMS W/ TUBSROOMS W/ ROLL IN SHOWER
01
20
10
31
ACCESSIBLE ROOMS W/ COMMUNICATION FEATURESHEARING IMPAIRED ROOMS 2 3 3 8
TOTAL SINGLE QUEENSTOTAL DOUBLE QUEENSTOTAL ROOMS
117
18
111223
101323
323264
AREA / SQUARE FT. 9,884 9,355 9,355 28,594
MA
IN F
LOO
R2N
D F
LOO
R3R
D F
LOO
R
3 ST
ORY
64
UN
ITU
NIT
PLA
NS
9ISSUE DATE: 1-16-16 REVISION DATE:
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR5 - ELEVATOR EQUIPMENT
6 - STAIR 7 - CORRIDOR 8 - MECHANICAL ROOM 9 - ELECTRICAL ROOM10 - MY STORE
11 - PUBLIC RESTROOM12 - GUEST LOUNGE13 - LOBBY14 - VESTIBULE15 - FRONT DESK
16 - OFFICE / WORKROOM17 - MECHANICAL18 - LAUNDRY / WORKROOM19 - GUEST LAUNDRY20 - STORAGE
9
8
5
4 36
7
1 1
1
12
13
15
1416
1718
1110
11
2 2
19
2 2
2
21
1
1
1 1
6
7
21
19
3 ST
ORY
64
UN
IT -
MA
IN F
LOO
RU
NIT
PLA
NS
10ISSUE DATE: 1-16-16 REVISION DATE:
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR
5 - ELECTRICAL AND COMMUNICATION OR HOUSEKEEPING6 - STAIR7 - CORRIDOR
5
4 36
7
1 1 1
11
2 2 2 2
22
21
1
1
1 1
6
7
22 2 22
1
3 ST
ORY
64
UN
IT -
2ND
FLO
OR
UN
IT P
LAN
S
11ISSUE DATE: 1-16-16 REVISION DATE:
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR
5 - ELECTRICAL AND COMMUNICATION OR HOUSEKEEPING6 - STAIR7 - CORRIDOR
5
4 36
7
1 1
11
2 2 22 2
22
21
1
1
1 1
6
7
22 2 22
1
3 ST
ORY
64
UN
IT -
3RD
FLO
OR
UN
IT P
LAN
S
12ISSUE DATE: 1-16-16 REVISION DATE:
DESIGN GUIDE ROOM MIX
GUEST ROOMS 1 2 3 TOTALSFLOOR LEVELSTUDIO QUEENSTUDIOACCESSIBLE STUDIO W/ ROLL IN SHOWERACCESSIBLE STUDIO
800
801
800
2401
DOUBLE QUEENDOUBLEEXTENDED DOUBLEACCESSIBLE DOUBLE
400
521
630
1551
ACCESSIBLE ROOMS W/ MOBILITY FEATURESROOMS W/ TUBSROOMS W/ ROLL IN SHOWER
00
20
00
20
ACCESSIBLE ROOMS W/ COMMUNICATION FEATURESHEARING IMPAIRED ROOMS 1 3 3 7
TOTAL SINGLE QUEENSTOTAL DOUBLE QUEENSTOTAL ROOMS
84
12
98
17
98
17
262046
AREA / SQUARE FT. 7,519 7,359 7,359 22,237
MA
IN F
LOO
R2N
D F
LOO
R3R
D F
LOO
R
3 ST
ORY
46
UN
ITU
NIT
PLA
NS
141’ 7”
67’ .
5”20
’
13ISSUE DATE: 1-16-16 REVISION DATE:
1
1
1
12 2
2
2
43
5
8
1011
12
13
14
15
16
17
18
19
20
9
6
7 7
6
1
1
1
1
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR5 - ELEVATOR EQUIPMENT
6 - STAIR 7 - CORRIDOR 8 - MECHANICAL ROOM 9 - ELECTRICAL ROOM10 - MY STORE
11 - PUBLIC RESTROOM12 - GUEST LOUNGE13 - LOBBY14 - VESTIBULE15 - FRONT DESK
16 - OFFICE / WORKROOM17 - MECHANICAL18 - LAUNDRY / WORKROOM19 - GUEST LAUNDRY20 - STORAGE 3
STO
RY 4
6 U
NIT
- M
AIN
FLO
OR
UN
IT P
LAN
S
14ISSUE DATE: 1-16-16 REVISION DATE:
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR
5 - ELECTRICAL AND COMMUNICATION6 - STAIR7 - CORRIDOR
1
1
12
2
34
5
6
7 7
6
2
2
22
2
21
1
11
1
1
3 ST
ORY
46
UN
IT -
2ND
FLO
OR
UN
IT P
LAN
S
15ISSUE DATE: 1-16-16 REVISION DATE:
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR
5 - HOUSEKEEPING6 - STAIR7 - CORRIDOR
1
1
12
2
34
5
6
7 7
6
2
2
2 2
2
2
21
1
1
1
1
3 ST
ORY
46
UN
IT -
3RD
FLO
OR
UN
IT P
LAN
S
16ISSUE DATE: 1-16-16 REVISION DATE:
DESIGN GUIDE ROOM MIX
GUEST ROOMS 1 2 3 4 TOTALSFLOOR LEVELSTUDIO QUEENSTUDIOACCESSIBLE STUDIO W/ ROLL IN SHOWERACCESSIBLE STUDIO
810
801
800
800
3211
DOUBLE QUEENDOUBLEEXTENDED DOUBLEACCESSIBLE DOUBLE
300
521
621
630
2072
ACCESSIBLE ROOMS W/ MOBILITY FEATURESROOMS W/ TUBSROOMS W/ ROLL IN SHOWER
01
10
10
10
31
ACCESSIBLE ROOMS W/ COMMUNICATION FEATURESHEARING IMPAIRED ROOMS 1 2 2 2 7
TOTAL SINGLE QUEENSTOTAL DOUBLE QUEENSTOTAL ROOMS
93
12
98
17
89
17
89
17
342963
AREA / SQUARE FT. 7,690 7,130 7,130 7,130 29,080
MA
IN F
LOO
R2N
D F
LOO
R3R
D F
LOO
R4T
H F
LOO
R
4 ST
ORY
63
UN
ITU
NIT
PLA
NS
141’ 7”
67’ .
5”20
’
17ISSUE DATE: 1-16-16 REVISION DATE:
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR5 - ELEVATOR EQUIPMENT
6 - STAIR 7 - CORRIDOR 8 - MECHANICAL ROOM 9 - ELECTRICAL ROOM10 - MY STORE
11 - PUBLIC RESTROOM12 - GUEST LOUNGE13 - LOBBY14 - VESTIBULE15 - FRONT DESK
16 - OFFICE / WORKROOM17 - MECHANICAL18 - LAUNDRY / WORKROOM19 - GUEST LAUNDRY20 - STORAGE OR ADDITIONAL RESTROOM
1 1
11
1 1
1
2
21
2
34
5
6 6
7 7
18
10 11
12
13
14
15
16
17
18
19
20
9
4 ST
ORY
63
UN
IT -
MA
IN F
LOO
RU
NIT
PLA
NS
18ISSUE DATE: 1-16-16 REVISION DATE:
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR
5 - ELECTRICAL COMMUNICATION OR HOUSEKEEPING6 - STAIR7 - CORRIDOR
1 1
11 1
1 1
1
2 2
2
2 2
22
34
5
6 6
7 7
1
4 ST
ORY
63
UN
IT -
2ND
FLO
OR
UN
IT P
LAN
S
2
19ISSUE DATE: 1-16-16 REVISION DATE:
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR
5 - ELECTRICAL COMMUNICATION OR HOUSEKEEPING6 - STAIR7 - CORRIDOR
5
34
7
6
1
1
1
1
12
2 2
2
2
2
2
2
21
1
1
6
7
4 ST
ORY
63
UN
IT -
3RD
FLO
OR
UN
IT P
LAN
S
20ISSUE DATE: 1-16-16 REVISION DATE:
ROOM GUIDE1 - STUDIO QUEEN2 - DOUBLE QUEEN3 - ELEVATOR LOBBY4 - ELEVATOR
5 - HOUSEKEEPING6 - STAIR7 - CORRIDOR
5
7
6
1
1
1
1
12
2 2
2
2
2
2
2
21
1
1
6
7
4 ST
ORY
63
UN
IT -
4TH
FLO
OR
4
UN
IT P
LAN
S
This brochure is only provided for informational purposes. All information, including specifications and drawings, is conceptual in nature, not intended for construction use, subject to change, and provided without any warranty. The contents of this brochure, including the architectural drawings and specifications, cannot be copied or reproduced in any manner.
Use of the specifications and drawings in this brochure is prohibited unless accepted by, and incorporated in specifications and drawings prepared by, a registered architect.Each My Place hotel is independently owned and operated.
My Place Hotels of America, LLCPO Box 4850 • Aberdeen, SD 57402
For Franchising Information ContactTerry Kline, Executive Vice President of Franchise Development
(605) 725-5685Or Email
My Place Hotels of America does not guarantee or promise success, profitability, or any particular level of return on investment for any My Place hotel. Many factors impact site selection and the success and profitability of a hotel, including site selection, local economic conditions, your business acumen, management skills, and experience. This brochure presents in general terms, an overview of the performance and features of a My Place hotel, and the My Place system. It does not constitute an offer to become a My Place Hotels of America franchisee or an offer to sign a franchise agreement. Becoming a franchisee requires the execution of a My Place Hotels of America franchise agreement by you. My Place Hotels of America only offers franchises through
its Franchise Disclosure Document (FDD) in states where it is registered to do so, or where registration is not required.