PROJECT
AREA
Grand Forks, ND
State of North Dakota County Map
David Kuharenko
Matthew Maguire
PROJECT
SITE
BOUNDARY
BEGIN PROJECT
STA. 1+33.81
END PROJECT
STA. 11+44.16
DESIGN DATA
TRAFFIC AVERAGE DAILY TRAFFIC COUNT
Pass:
Pass:
Truck:
Truck:
Total: 10,186
Total: 23,220
Clear Zone Distance: 14
Minimum Sight Dist. for Stopping:
Limited Access Control: N/A
Pavement Design Life: 30 Years
Design Accumulated One-way N/A ESALs: N/A
Design Speed: 40
Bridges: N/A
Current 2015
Forecast 2040
STATE PROJECT NO. PCN SECTIONNO.
SHEET NO.
ND SU-6-986(120)124 21589 2 1
8/10/2017 3:27:24 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\02-01 Table of Contents.doc
TABLE OF CONTENTSSection No. Sheet No. Description
1 1 Title Sheet2 1 Table of Contents4 1 Scope of Work6 1-6 Notes8 1 Quantities
10 1 Basis of Estimate11 1 Earthwork Summary20 1-9 General Details30 1 Existing Typical Section30 2 Proposed Typical Section40 1 Removals55 1 Storm Plan and Profile60 1-2 Paving Plan & Profile76 1 Temporary Erosion Control77 1-2 Permanent Erosion Control80 1-2 ADA Ramp Details90 1 Joint Layout
100 1 Traffic Control Devices List100 2-4 Work Zone Traffic Control100 5 Pedestrian Detour120 1-3 Marking140 1 Lighting Layout150 1-2 Traffic Signal Layout150 3-6 Signal Standard & Head Locations150 7 Signal Heads & Conductor Schedule150 8 Signal Controller Phasing150 9 Traffic Signal System Quantities150 10 Detector Zone Layout150 11 Sign Design Details160 1 Fiber Optic Interconnect200 1-7 Cross Sections
LIST OF SPECIAL PROVISIONSSP # Description
SP 0530(14) Video Detection System
LIST OF STANDARD DRAWINGSStandard No. Description
D-101-1,2,3 NDDOT AbbreviationsD-101-10 NDDOT Utility Co and Org AbbreviationsD-101-20,21 Line StylesD-101-30,31,32 SymbolsD-704-7,8 Breakaway Systems for Construction Zone SigningD-704-9 Construction Sign DetailsD-704-13 Barricade and Channelizing DevicesD-704-14 Construction Sign Punching and Mounting DetailsD-704-34 Sign Layout for One Lane Closure D-714-1 Reinforced Concrete Pipe Culverts and End SectionsD-714-18 Edge Drain DetailsD-714-26 Transverse Mainline Pipe Installation Detail Pipes 4 Feet or Less Below Top of SubgradeD-722-2 Inlet – Type 2D-748-1 Curb & Gutter and Valley GutterD-750-2 SidewalkD-750-3 Curb Ramp DetailsD-754-1 Pipe or W-Shape Assembly DetailsD-754-23 Perforated Tube Assembly DetailsD-754-24 Mounting Details Perforated TubeD-754-24A Breakaway Coupler System for Perforated TubesD-754-25 Mounting Details Perforated TubeD-754-80 Light Standard, Signal Standard and Span Wire Mounted Sign Assembly DetailD-770-1 Concrete foundations (Traffic Signals & Highway Lighting)D-770-2A Combination Feed Point DetailD-770-3 Pull Box DetailD-770-5 Light Standard DetailsD-772-2 Traffic Signal StandardsD-772-3 Traffic Signal Standards (Mast Arm Type)D-772-4 Traffic Signal Head Mounting
FOFO
FO FOFO
FO FOFO
FOFO
FO
FOFO
U
G
C
UGC
UG
C
UG
C
UGC
U
G
E
G
A
S
FOFOFOFOFOFO
FOFOFOFO
FOFO
FO
FO
FO
FO
FOFO
FO FOFO
FO FOFO
FOFO
FO
S. WASHINGTON ST.
44
TH
A
VE
. S
.
Feet
0 80 160
42
ND
A
VE
. S
.
CONSTRUCT NEW STORM SEWER
CONSTRUCT NEW STORM SEWER
CONSTRUCT LEFT TURN LANE
CONSTRUCT LEFT TURN LANE
INSTALL NEW TRAFFIC SIGNAL SYSTEM
REALIGN SIDEWALKS & BIKEPATHS
REALIGN SIDEWALKS & BIKEPATHS
PLACE NEW FIBER LINE AND CONDUIT
INSTALL NEW TRAFFIC SIGNAL SYSTEM
INSTALL NEW ELECTRICAL CABLE
IN EXISTING CONDUIT
BEGIN PROJECT
STA 1+33.81
END PROJECT
STA. 11+44.16
Legend
Realign Left Turn Lanes
Sidewalk/Shared Use Path
ND
SU-6-986(120)124 21589 4 1
SCOPE OF WORK
S. WASHINGTON ST. & 44TH AVE. S.
NOTES
8/10/2017 3:30:52 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\06-Notes.doc
STATE PROJECT NO. PCN SECTIONNO.
SHEET NO.
ND SU-6-986(120)124 21589 6 1
This document was originally
issued and sealed byDavid J. KuharenkoRegistration Number
PE-8411on 08/10/2017.
The original document isstored at the City of Grand
Forks, North Dakota.
NOTES
S. WASHINGTON ST. & 44TH AVE. S.
105-110 Pavement Sweeping: Sweep paved areas that were used by construction traffic before opening these areas to public traffic. Sweep all newly constructed pavement no more than 24 hours before a scheduled final inspection. Use a vacuum or pickup type sweeper to perform this work.
107-P01 Noise Restrictions: Comply with the City of Grand Forks noise ordinance. Schedule operations between the hours of 6:30 AM and 10:00 PM, Monday through Saturday. Should work need to be done outside this range, make a written request to the Grand Forks Public Health Department at 151 South 4th St, Suite N-301, Grand Forks, ND 58201-4735.
Contractor may not request one permit to cover all work for the entire project duration. All requests shall be made at least 72 hours in advance, stating the specific nature of the work, additional hours required and the number of days needed to complete the specified work. The Contractor shall obtain approval from the Health Department 24 hours prior to beginning work. The contractor shall also furnish a copy of the approved permit to the Grand Forks Police Department and Engineer a minimum of 24 hours prior to beginning of work and notify them of the days and hours planned for work under this permit.
202-P01 Removal of Pavement: The bid item “Removal of Concrete Pavement” consists of the removal of all concrete material: Sidewalks, Pavement and Medians. All concrete materials paid for as removal have been deducted from the excavation quantity.
202-P02 Removal of Pipe: The bid item “Removal of Pipe All Types and Sizes” shall include excavation, removal, clay backfill and compaction of pipe trench, and disposal of all pipe sections as well as all labor materials, and equipment required to complete this work.
202-P03 Removal of Signs: Removal of signs and posts shall be incidental to the project.
203-P01 Common Excavation – Type B: The bid item “Common Excavation – Type B” shall include grading (cutting & filling). Measurement for purpose of payment for this item will be based on the plan quantity of excavation (cut only) from existing elevations to the final clay sub grade and berm elevations with topsoil in place. Upon completion of path construction and adjacent berm shaping, Contractor shall place a minimum of 6” of topsoil on the disturbed areas adjacent to the realigned turn lanes, sidewalks, shared use paths, signals, pedestrian push buttons and pull boxes. Topsoil placement and any necessary embankment shall be considered incidental to the “Common Excavation – Type B” bid item. In addition to the requirements of Section 203, excess excavated material shall become the property of the Contractor and shall be removed from the project site.
203-P02 Topsoil: Strip and salvage all topsoil on areas to be disturbed to be reused on the project. Any excess topsoil not used for shaping, grading or filling shall become the property of the contractor. This work shall not be bid separately, but shall be included in the cost for bid item “Common Excavation - Type B.”
203-P03 Type A Compaction: All fill required for storm sewer work shall be compacted to a minimum of 95% density (AASHTO T-99). The City accepts the existing clay soil to be 100 pounds per cubic foot with optimum moisture of 23%.
251-P01 Seeding Class III: Rake the final topsoil surface smooth to provide positive drainage. Seed disturbed areas with the following Class III seed mixture:
Grass Species Percentage Pure Live Seed
Creeping Red Fescue 40%Kentucky Bluegrass 25%Perennial Rye Grass 20%Southport Chewings Fescue 15%Total 100%
Seed Application Rate 260 lbs/acre
Water and maintain seeded areas a minimum of four weeks after placement in order to provide sufficient moisture for growth as determined by the Engineer. Watering and maintenance shall continue until final acceptance. Prevent runoff and puddling. Do not drive watering trucks over turf areas, or sidewalks.
Maintenance of the seeded areas includes eradicating weeds, maintaining erosion control devices and mulch, protecting installed areas from traffic, mowing, and watering.
Mow seeded areas to height of 3 inches with cutting no more than 1/3 of the grass leaf. Mow seeded areas 24 hours prior to final inspection.
Seeded areas will be rejected if they contain excessive weeds or bald spots larger than 3" in diameter.
Include the cost for materials, equipment, labor, maintenance, and incidentals in the contract unit price for “Seeding Class III”.
302-P01 Salvaged Base Course: The bid item “Salvage Base Course” shall be paid for at plan quantity and no separate measurement or payment will be made, unless changes are made to the plan. At Contractor’s option, Contractor may substitute Salvage Base Course with Aggregate Base Course CL 5. Substituted material shall be paid for as “Salvage Base Course”.
550-P01 Tie Bars: All tie bars shall be Grade 60 and placed according to the joint details as shown on the plans. All tie bars required for installation into new or existing concrete pavements shall be grouted into a pre-drilled hole with an approved epoxy grout. Prior to grouting bar in place, the pre-drilled hole shall be cleaned with compressed air and prepared as recommended by the epoxy grout manufacturer.
550-P02 Concrete Joints: Saw cut joints in newly
NOTES
8/10/2017 3:30:52 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\06-Notes.doc
STATE PROJECT NO. PCN SECTIONNO.
SHEET NO.
ND SU-6-986(120)124 21589 6 2
This document was originally
issued and sealed byDavid J. KuharenkoRegistration Number
PE-8411on 08/10/2017.
The original document isstored at the City of Grand
Forks, North Dakota.
NOTES
S. WASHINGTON ST. & 44TH AVE. S.
installed pavement shall follow the joint alignment and locations of existing pavement joints.
704-P01 Traffic Control Devices: Traffic control is based on NDDOT Std D-704-34, Sign Layout for One Lane Closure.
722-P01 Adjust Gate Valve Box: Adjust gate valve boxes plumb and to finished surfaces by rotating the valve box or adding an additional valve box section. Include the costs of all materials, equipment, labor, and incidentals in the contract unit price for “Adjust Gate Valve Box”.
722-P02 Adjust Manhole: Adjust existing manhole castings to finished surface. Prevent debris from falling into manholes and promptly remove any falling debris. Provide protective wrapping over manhole covers prior to placement of concrete. Clean any manhole cover coated with concrete.
722-P03 Rubber Seal: Provide external rubber seals Inlet-Type 2 Double structures. Provide seals extruded from a continuous seamless band of high-quality Ethylene Propylene Diene Monomer (EPDM) rubber with a minimum thickness of 65 mils and with molded preformed L shaped corners. Provide seals with attached minimum 2” wide butyl mastic to the inside top and bottom of the seal to provide bonding to the structure and over the flange on the casting frame. Use aerosol primer to improve bonding strength of the seal. Include the cost of rubber seals in the contract unit price for “INLET-TYPE 2 DOUBLE”.
748-P01 Curb and Gutter-Type I: Provide Grade 60 reinforcing steel and tie bars. Install reinforcing steel with a minimum tied lap length of 24 inches. Place tie bars into pre-drilled hole, cleaned with compressed air, and grouted with an approved epoxy grout. Placement of tie bars into plastic concrete will not be allowed.
750-P01 Concrete Median Nose Paving: Measurement will be from the beginning of the curb radius to the end of the curb radius at the street intersection, including the triangular area between the curb face and the mainline paving.
750-P02 Sidewalk: Over excavated areas beneath the sidewalk removal areas shall be filled with aggregate base and compacted. All costs for labor, materials, and equipment for the aggregate base shall be included in the bid item “Sidewalk Concrete-5in”. Contraction joints shall be constructed so as to divide the sidewalk into square slabs, the greatest longitudinal or transverse dimension of whish shall not exceed 5 feet.
750-P03 Pavement Reinforcement: Cost of steel reinforcement for concrete shared use path and sidewalks shall be included in the respective bid items being installed. All reinforcing steel shall be Grade 60.
750-P04 Detectable Warning Panels: Detectable warning panels shall be yellow in color.
754-P01 Sign Supports: The "Steel Galvanized Post - Perforated Tube" posts shall have all holes punched completely. All metal shall be removed from the punched holes.
762-P01 Epoxy Pvmt Mk Curb Top & Face: Include costs for materials, equipment, labor, and incidentals to paint the median and median nose paving in the contract unit price for “Epoxy Pvmt Mk Curb Top & Face”.
770-P01 Revise Lighting System: The bid item “REVISE LIGHTING SYSTEM” will include all materials, equipment, and labor required to revise the lighting system as shown in the plans. This work includes removal and salvaging of street lights and luminaries, removal of foundations, removal of the existing feed point, pull boxes, connections to existing circuits to remain, furnishing and installation of new conduit, conductors, lighting standards and LED luminaries, and other miscellaneous items required for a fully operational street lighting system. All salvaged materials shall be delivered to the City Electrician, Rick Hanson (218-779-4362), at 724 N 47th Street.
770-P02 Lighting Circuits Testing: All newly installed street lighting circuits shall be tested with a megohmmeter in the presence of the city electrician or city electrical inspector. The test shall be done at a minimum of 5,000 volts with no reading below 50 meg. Any conductors failing this test shall be replaced. The cost of testing shall not be bid separately, but shall be considered incidental to the project.
770-P03 Conductor: All multiple underground cables and underground conductors required for connection to light standards and feed points shall be single conductor assemblies, without overall armor or jacket. Insulation shall be color coded with one red, one black, and one white NO 4 and one green NO 6 cable. Ungrounded and neutral cable types shall be RHW-USE suitable for direct buried applications. Equipment ground cables shall be RHW-USE or THW. The quantities shown in the Plans for the bid item “Revise Lighting System” are based on the total length of each conductor size. Conductors in Lighting Standards shall be SEO 14/3 stranded copper with ground cable, Electrical Conductors, Inc. or approved equal. Receptacles and luminaires shall have separate cables. Cable shall be rated for use from -50 degrees C to +105 degrees C. Cable to be supported by a single eye closed mesh support grip for the cable attached to one of the luminaire pole stops as approved by the Engineer. Also see Plan details. All splicing shall be in pole bases. All leads shall be brought out at least 12” beyond the hand hole/ Splice assemblies shall be tied together with plastic tape or cord and a tag end left under the hand hole cover to facilitate retrieving splices for future service. Splices shall be Polaris IT-4, Burndy, ILSCO insulated splice or equal. All poles shall have in-line fuse holders on all ungrounded conductors. Use Bussman Tron HEBB-AA, Littelfuse, Gould-Shawmut, or approved equal fuse holder. Provide 3 amp time delay fuses. Festoon receptacle outlets shall be separately fused. Underground splices are prohibited.
770-P04 Luminaires: The LED luminaires shall be Cree Model BXSP@-HO-HT-3m3-165W40K-UL-SV-N-Q9, American Autobahn Model No ATB2-40BLEDE13-MVOLT-NL or approved equal. The finish shall be gray enamel. All costs associated with the installation of new luminaires heads shall be included in price bid for “REVISE LIGHTING SYSTEM”.
NOTES
8/10/2017 3:30:52 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\06-Notes.doc
STATE PROJECT NO. PCN SECTIONNO.
SHEET NO.
ND SU-6-986(120)124 21589 6 3
This document was originally
issued and sealed byDavid J. KuharenkoRegistration Number
PE-8411on 08/10/2017.
The original document isstored at the City of Grand
Forks, North Dakota.
NOTES
S. WASHINGTON ST. & 44TH AVE. S.
770-P05 Traffic Signal and Luminaire System Power Source: Obtain the electrical source necessary to operate the lighting system. Make the necessary arrangements with the utility to provide for the electric service, which may come from the existing pad mounted transformer or a new transformer in the same location. The electric utility is Xcel Energy. Costs for electric service, including three 3/0 copper service cables in 3” PVC conduit and grounding as required by the NEC, shall be included in the price bid for “REVISE LIGHTING SYSTEM”.
770-P06 Padlocks: Obtain padlocks for feed points from the City of Grand Forks.
772-P01 Traffic Signal System: The price bid “TRAFFIC SIGNAL SYSTEM” shall include all labor and equipment necessary for each signal system to be fully operational as shown in the plans upon construction completion. This includes, but is not limited to, the installation of the following features where applicable; traffic signal standards, mast arms, feed point type IV ped mounted, pedestrian pushbuttons, pushbutton posts and signs, vehicular and pedestrian heads, video detection system, controller, controller battery back-up, cabinet, foundations, revisions to the existing fiber optic interconnect system, along with all cable, conduit, junction boxes, pull boxes, and appurtenances to install the traffic signal completely. This also includes the removal of the existing wiring and any other abandoned features that may conflict with the proposed traffic signal system improvements. This also includes connections with lighting as noted in 770-P01 through 770-P05.
772-P02 Field Verification: Verify all features labeled “Existing” are approximately located. Verify the location of all proposed signal and lighting features including all proposed conduit to avoid conflict with any utilities or any other features potentially encountered in the field.
772-P03 Signal Testing and Initial Operation: When not in operation, the signal head shall be hooded with a material that will allow the signal heads, when lit, to be seen dimly by personnel testing the signals. The hood shall remain in place until the signal is authorized to be operated. The cost of testing shall not be bid separately, but shall be included in the price for “TRAFFIC SIGNAL SYSTEM.”
772-P04 Traffic Signal Controller: Furnish the controller cabinet and auxiliary control equipment furnished from a manufacturer whose Econolite Cobalt RM with Transit Key/2M Series NEMA TS2/NTCIP operates on Centracs Software which has been approved by the City of Grand Forks. Price bid for “TRAFFIC SIGNAL SYSTEM” includes all labor, materials and equipment required to install the new controller, including but not limited to the emergency vehicle pre-emption unit, cabinet, new detector amplifiers (furnished and installed), other ancillary signal components (such as load switches, conflict monitors, etc.) and controller cabinet components connected as required to make the new controller equipment operational with the existing and proposed signal equipment.
772-P05 Grand Forks Traffic Signal Cabinet: Use Econolite 332D, pre-wired with ancillary components including a RENO A&E Traffic Signal Conflict Monitor with Ethernet port. Adhere to the City of Grand Forks Cabinet Specifications as specified in the plans at Traffic Control Corporation. The price bid for “TRAFFIC SIGNAL SYSTEM” Includes all costs, labor, materials and equipment necessary for furnishing and installing the cabinet.
772-P06 Concrete Controller Cabinet Pad: The price bid for “TRAFFIC SIGNAL SYSTEM” includes a new concrete pad to mount the proposed traffic signal cabinet. Size the concrete pad for a Type 332D Cabinet as specified in the plans.
772-P07 Battery Backup System: Provide a battery backup system for the traffic signal system. The price bid for “TRAFFIC SIGNAL SYSTEM” includes all costs, labor, materials and equipment necessary for furnishing and installing the battery backup system. Include the following minimum requirements:• Provides full battery backup for the traffic controller in normal or flash operation• Flash activation contacts to ensure the longest possible battery life• Rack mountable for installation in a 332D Cabinet or NEMA rated outdoor pad mounted enclosure, as required• Power conditioning and transient filtering• True Sine wave output with ±2% voltage regulation• Power management and diagnostic functions• Ethernet port with software to monitor or download data logs of the battery backup system • Suitable for operation from -40°F to 120°F• Battery backup for a minimum of 3 hours of flash operation• Capable of running the intersection for 30 minutes at 1000 watts and then switch to flash operation to conserve power• The UPS shall include an external bypass switch rated at 30 amp 250 VAC and shall use 30 amp relays.
772-P08 Emergency Vehicle Pre-Emption and Transit Priority: Use GTT Global GPS Vehicle Preemption; model 764 phase selector, Model 1010 GPS Radio Unit containing a GPS receiver with Antenna and a 2.4 Ghz Spread Spectrum Transciever with Antenna and Model 1070 GPS Installation Cable.
The location of the GPS EVP detector as denoted in the plans may vary based upon GPS signal availability. No splices are allowed between the controller cabinet and the EVP Equipment on the pole/arm. All indicator lamps are LED.
Compatible with the other EVP equipment used within the City of Grand Forks. Provide all labor and equipment necessary for the emergency vehicle preemption system to be fully operational. Notify City of Grand Forks fire chief Peter O’Neill (701-746-2566) and city electrician Rick Hanson (701-738-8796) when the proposed signalized intersection EVP system is tested and operable. The price bid for “TRAFFIC SIGNAL SYSTEM” includes all costs, labor, materials and equipment necessary for furnishing and installing the EVP system.
772-P09 Conflict Monitor: The traffic signal controller conflict monitor shall be a RENO A&E model, Ethernet connection. A complete controller conflict monitor test shall be performed by the Contractor prior to unveiling the traffic heads. All materials, labor and equipment necessary to conduct the conflict monitor testing shall be included in the price bid “TRAFFIC SIGNAL SYSTEM.”
NOTES
8/10/2017 3:30:52 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\06-Notes.doc
STATE PROJECT NO. PCN SECTIONNO.
SHEET NO.
ND SU-6-986(120)124 21589 6 4
This document was originally
issued and sealed byDavid J. KuharenkoRegistration Number
PE-8411on 08/10/2017.
The original document isstored at the City of Grand
Forks, North Dakota.
NOTES
S. WASHINGTON ST. & 44TH AVE. S.
772-P10 Controller Monitoring Unit and/or Communication Module: The volume density controller shall be provided with a communication hookup which provides a duplex data link with a central control computer. The communications hookup shall be PC compatible. A controller monitoring unit and/or communication module shall be installed in the controller. The monitor unit shall be installed and connected to the controller and conflict monitor so as to monitor conflict monitor flash, pre-emption status, cabinet door open, phase on and status bits required for central control intersection display, and detector diagnostics. The unit shall be capable of providing a traffic map and of uploading and downloading information into the controller from a PC, central control computer or a laptop in the field, or a telephone line. All costs, labor, materials and equipment necessary for furnishing and installing this item shall be included in the price bid for “TRAFFIC SIGNAL SYSTEM.”
772-P11 Shop Drawings: Furnish shop drawings and a complete listing of materials proposed for installation. Provide two copies to the City of Grand Forks Traffic Engineer, plus any additional sets that need approval and that are to be returned for the Contractor’s use. Provide the Engineer with proof of purchase, and delivery and manufacturing schedules for traffic signal materials indicating that acquisition of these materials is consistent with progress and completion requirements of this contract.
772-P12 Traffic Signal Head Mountings: Furnish piping to mount the vehicle and signal heads to the side of the poles. Do not mount heads directly to the pole or on the face of the pole directly adjacent to the street. No banding permitted. The price bid for “TRAFFIC CONTROL SYSTEM” includes all costs, labor, materials and equipment necessary for installing traffic signal heads.
772-P13 Traffic Signal Standards - Transformer Base: Use “T” transformer base type standards. The price bid for “TRAFFIC SIGNAL SYSTEM” includes all costs, labor, materials and equipment necessary for furnishing and installing the “T” transformer base.
772-P14 Vehicular Traffic Signal Heads: Use 12 inch vehicular signal heads with aluminum housings for each section. Equip all sections with General Electric GTX LED illuminating elements conforming to the Institute of Transportation Engineers Equipment and Materials Standards and Specifications. Price bid for “TRAFFIC SIGNAL SYSTEM” includes all costs, labor, materials and equipment necessary for furnishing and installing the vehicular traffic signal heads.
772-P15 Pedestrian Signal Heads: Equip with LED illuminating elements displaying the pedestrian signals as shown. Price bid for “TRAFFIC SIGNAL SYSTEM” include all costs, labor, materials, and equipment necessary for furnishing and installing the pedestrian signal heads.
772-P16 Conduit: Install conduit at the locations shown on the plans. Bore conduit under existing pavement. Dig potholes to verify that the conduit avoids the existing utility as necessary. Price bid for “TRAFFIC SIGNAL SYSTEM” and “REVISE LIGHTING SYSTEM” include furnishing and installing conduit, pushing and boring conduit, digging potholes and restoring the potholes with new material that ties into the existing surround material. Seal all conduits with duct seal at the controller cabinet and at the traffic signal standard foundations. Conduit types may be either schedule 40 PVC or HDPE conduit with a wall thickness equivalent to schedule 40 (Refer to NDDOT specification). HDPE conduit shall be UL listed.
772-P17 Pull Boxes: Follow the specification outlined in the NDDOT standard drawing D770-3 and be PVC with steel casting including a traffic resistant cast iron cover.
772-P18 Label All Field Cables: All labeling materials must be approved by the City. Labels must be readable without moving the cables. When installing cable bundles in conduit, bundles will not be taped. Label all field cables with the cable designations:
TYPE LABEL LABLE LOCATIONCommunication Cable Comm./address of other end Within 12" of conduitPedestrian Push Button
Phase/location (i.e. NW, SW, etc.) Within 6" of terminals
Video Camera Cables Detection zone (i.e. D2-1, D2-2, etc.) Within 6" of terminalsControl Cable Cable number & location (i.e. NW, SW, etc.) Within 12" of conduitOpticom Cable Pre-empt number/location (i.e. NW, SW,
etc.)Within 6" of terminal
Price bid for “TRAFFIC SIGNAL SYSTEM” and “REVISE LIGHTING SYSTEM” includes all costs, labor, materials and equipment necessary for labeling field cables.
772-P19 Pedestrian Pushbuttons, Housing, and Signs: Pedestrian push buttons, housings and signs shall be furnished with the ability to be bolted directly to the traffic signal standards. Bandit shall not be permitted. The pushbuttons should be 3” round and vandal resistant, solid state pressure sensitive non move Piezo yellow pedestrian push button station with visual and audible press and release feedback with a 5" X 7" frame up. TS 2 compliant switch rated for 100 X 106 operations with a 75 ms closure with a mounting for 4 bolts. The housings are for a 3 inch round push button with a 4 bolt (2.60 +/- .05”) circle and displays a 5" X 7” sign. The top of the push-button signs shall not extend above the top of the pedestrian push-button post Complete with mounting hardware and signs compatible with the provided housings shall be provided. The pedestrian push buttons shall meet ADA and MUTCD minimum requirements, specified for pedestrian countdown pushbuttons. All costs of material, delivery, and installation for pedestrian push buttons, housing, and signs shall be included in the price bid for “TRAFFIC SIGNAL SYSTEM”.
772-P20 Additional Conduit: Install one additional 4-inch diameter conduit in the controller cabinet/feedpoint foundation. The direction of the conduit will be determined in the field by the engineer. Cap all conduit. Price bid for “TRAFFIC SIGNAL SYSTEM” include all costs to supply and install the additional conduit.
772-P21 Conductor Color Continuity: Maintain conductor color continuity where any 14 AWG 12 conductor cables are connected to 14 AWG 5 and/or 14 AWG 3 conductor cables within the terminal block of a traffic signal standard.
NOTES
8/10/2017 3:30:52 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\06-Notes.doc
STATE PROJECT NO. PCN SECTIONNO.
SHEET NO.
ND SU-6-986(120)124 21589 6 5
This document was originally
issued and sealed byDavid J. KuharenkoRegistration Number
PE-8411on 08/10/2017.
The original document isstored at the City of Grand
Forks, North Dakota.
NOTES
S. WASHINGTON ST. & 44TH AVE. S.
772-P22 IT System: The bid price for “IT SYSTEM” includes all labor and equipment necessary to interconnect all of the traffic signals within the project limits as shown in the IT plans. This includes but is not be limited to all fiber optic cable, pull boxes, conduit, future conduit, conduit sweeps into existing pull boxes and connections required for the interconnected system to be fully operational, furnishing and installing Ethernet switches and fiber splice boxes/enclosures sized for all fibers at each signalized intersection, and removing a portion of the existing fiber optic cable, protecting it and salvaging it for reinstallation as shown in the plans.
772-P23 Ethernet Switch: The Ethernet Switch shall be produced by RuggedComm and shall be model type RuggedSwitch RS900G-2L, contain dual fiber optic Gigabit Ethernet ports, and have two (2) single-mode fibers with LC connectors in and out included for the for the connections. Price bid for “IT SYSTEM” includes all costs, labor, materials and equipment necessary for furnishing and installing the Ethernet switch.
772-P24 IP Address: The Contractor shall coordinate with the City of Grand Forks to obtain any required IP addresses during installation.
772-P25 INTERCONNECT CABLE: The fiber optics interconnect cable shall include one (1) 24 multimode (12 pairs) and 24 single-mode hybrid fiber optic hardwire for aerial and duct application, compatible with Daisy-chain operation, for the purpose of controlling traffic in a coordinated closed-loop system. The Contractor shall use one (1) pair of single-mode fiber for traffic signal controller interconnection and one (1) pair of single-mode fiber for the entire video detection system. Fibers shall terminate in the appropriate switch within the traffic signal controller and all fiber both single and multi-mode shall be terminated in the panel. The optical cable shall be dielectric, loose-tube, dry block, filled with a single polyethylene jacket and reinforced with aramid yarn. The optical specifications shall meet RUS 7 CFR 1755.900 (PE-90) and Telcordia GR-20 Standards for single-mode cable. Single mode fiber shall be 8.3/125 micrometer in diameter, zero water peak. The attenuation shall be less than or equal to 0.4 dB/km at 1310nm; less than or equal to 0.32 dB/km at 1383 nm and less than or equal to 0.3 dB/km at 1550nm. Multimode fiber shall be 62.5/125 micrometer in diameter, zero water peak. The attenuation shall be less than or equal to 3 dB/km at 850 nm and less than or equal to 1 dB/km at 1550 nm. The temperature range shall be -40⁰C to +70⁰C.The contractor shall provide 25 feet of additional interconnect for each incoming and outgoing conduit run at every pull box, traffic signal controller. The cable manufacturer shall provide the Engineer with documentation indicating the attenuation and bandwidth for individual fibers on each reel within five business days after delivery of the cable. The cable shall again be tested after connectors are installed. Contractor shall disconnect the fiber optic cable from the cabinet located at 47th Ave S and pull this cable through the new pull box and conduit to the new controller located at 44th Ave S to make the connection between the cabinets at 40th Ave S and 44th Ave S. Contractor will install new interconnect cable between the cabinet at 44th Ave S and 47th Ave S. All labor, materials and equipment necessary for fiber optic interconnection shall be included in the price bid for “IT SYSTEM.”
772-P26 Tracer Conduit: The interconnect cable conduit shall have a tracer conductor installed and labeled in each controller cabinet. The tracer conductor shall consist of a No. 14 AWG - Type THW single conductor as specified in Standard Specification section 895.03A1. The conductor shall be continuously unspliced from control cabinet to control cabinet. The cost of furnishing and installing this conductor shall not be bid separately but shall be included in the price bid for “IT SYSTEM.”
772-P27 Maximum Tensile Pull Strength: Do not exceed a maximum tensile strength of 600 pounds when pulling the fiber optic interconnect cable.
772-P28 Signal Timing and Coordination: Deliver the controller and cabinet to the City Electrician, Rick Hanson (701-738-8796), at the Public Works Department located at 724 N 47th Street. Provide controller preloaded with signal timing and coordination settings as provided by the City. The City Electrician will conduct operational tests and operate the controller for a test period of 30 consecutive days at the Public Works Department shop without any malfunctions of the controllers. Any controller that does not operate satisfactorily for the 30 days will be rejected and replaced. After the controllers have operated satisfactorily for the 30 days, they will be approved by the City of Grand Forks. The price bid “TRAFFIC SIGNAL SYSTEM” include all labor, materials and equipment necessary for furnishing and installing the controllers, as well as delivery to City Electrician.
772-P29 Malfunction Management Unit: Use RENO A&E model with an Ethernet port. Perform a complete controller malfunction management unit test prior to unveiling the traffic heads. Price bid for “TRAFFIC SIGNAL SYSTEM” includes all labor, materials and equipment necessary to furnish and install the unit and to conduct the malfunction management unit testing.
772-P30 Pedestrian Push Button Post: Use SMP2 with breakaway tabs, per TIP indications with anodized natural gray finish. Paint pedestrian pushbutton housing black (use #27038 of Federal Standard No. 595B). Price bid for “TRAFFIC SIGNAL SYSTEM” includes all costs, labor, materials and equipment necessary for furnishing and installing the pedestrian push button posts.
772-P31 Pedestrian Push Button Units: Install Advisor Advanced Accessible Pedestrian System (AAPS) pedestrian push buttons. Mount each pedestrian sign and pushbutton on one framed enclosure to the signal pole or bolt directly to the pedestrian pushbutton post. Bandit is not permitted. Do not extend the top of the pushbutton signs above the top of the pedestrian pushbutton post. Include the Advisor Advances APC Pedestrian Controller and compatibility remote network ether connection for real time monitoring and control of operating parameters. SMP2 High Visibility Pedestrian Station for standalone pushbutton posts. Price bid for “TRAFFIC SIGNAL SYSTEM” includes all costs, labor, materials and equipment necessary for furnishing and installing the pedestrian pushbutton units.
772-P32 Signal Standard Paint Color: Paint all traffic signal system components in accordance with the following:
Transformer base-black Mast arm-black Signal head mounting hardware-black Signal housing-black
Use #27038 of Federal Standard No. 595B for the color black.
NOTES
8/10/2017 3:30:52 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\06-Notes.doc
STATE PROJECT NO. PCN SECTIONNO.
SHEET NO.
ND SU-6-986(120)124 21589 6 6
This document was originally
issued and sealed byDavid J. KuharenkoRegistration Number
PE-8411on 08/10/2017.
The original document isstored at the City of Grand
Forks, North Dakota.
NOTES
S. WASHINGTON ST. & 44TH AVE. S.
772-P33 Excavation and Restoration: Any Excavation required to install conduit, connect conduit to existing conduit sweeps, install pull boxes, foundations or any other feature proposed in the plans is included in the prices bid “TRAFFIC SIGNAL SYSTEM”, “REVISE LIGHTING SYSTEM”, and “IT SYSTEM”. This includes restoring the excavated area with the appropriate fill material. The fill material shall match the surrounding surface material. At locations where the surrounding material is earth, include earth fill with 6” of topsoil and seed or sod. At locations where the surround material is concrete, tie into the existing concrete. All removed material whether concrete or earth is the property of the Contractor and be disposed of accordingly. Compaction and density controls are in accordance with Section 203.04 E.2 of the Standard Specifications AASHTO T-99.
772-P34 Wire Splicing: No splicing will be allowed in pull boxes. Splicing may only take place in the signal base.
772-P35 Feed Point-Type IV Mounted: Connect the traffic signal controller to the new feed point. Install a new 50 amp breaker Type BR at the feed point for traffic control signal purposes.
The feed point will have two for Roadway Lighting and Traffic Signals. Contact Deb Thompson with Xcel Energy (701-795-5229). Coordinate with the utility company to establish the service connection to ensure a fully operational traffic signal controller feed point at this location.
All utility company costs for the new feed point shall be paid by the Contractor. Furnish and install new conduit from the new controller cabinet to the new feed point. Furnish and install #6 U.S.E. cable between the new controller and the new feed point. Price bid for “TRAFFIC SIGNAL SYSTEM” includes all costs, labor, materials and equipment required for feed point connections.
Provide 14 gauge #304 stainless steel cabinet of adequate size to house the specified number of circuits and equipment shown on the feed point detail. Tie transformer ground into cabinet grounding lug and neutral lug.
Provide enclosures with a subpanel for complete dead-front access to all, main disconnect handles, circuit breaker handles and toggle test switches. Use plug in type breakers with specified amperage, 10,000 AIC.
Mount photoelectric (PE) cells externally on the feed point cabinet, facing east or north. Use EEI/NEMA type PE sockets. Provide PE control with a time delay of at least 15 seconds and rated for 240 volt.
QUANTITIES
8/11/2017 1:58:18 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\08-01 Quantitites.doc
STATE PROJECT NO. PCN SECTION
NO. SHEET
NO.
ND SU-6-986(120)124 21589 8 1
This document was
originally
issued and sealed by
David J. Kuharenko
Registration Number
PE-8411
on 08/10/2017.
The original document is
stored at the City of Grand
Forks, North Dakota.
QUANTITIES
S. WASHINGTON ST. & 44
TH AVE. S.
SPEC NO. CODE NO. ITEM DESCRIPTION UNIT QUANTITY
103 0100 CONTRACT BOND L SUM 1
202 0114 REMOVAL OF CONCRETE PAVEMENT SY 609
202 0130 REMOVAL OF CURB AND GUTTER LF 1059
202 0174 REMOVAL OF PIPE ALL TYPES AND SIZES LF 46
202 0230 REMOVAL OF INLETS EA 2
203 0102 COMMON EXCAVATION-TYPE B CY 786
251 0300 SEEDING CLASS III AC 0.07
253 0201 HYDRAULIC MULCH AC 0.07
302 0101 SALVAGE BASE COURSE CY 534
550 0112 8IN NON-REINF CONCRETE PAVEMENT CL AE SY 1355
550 0113 8IN REINFR CONCRETE PAVEMENT CL AE SY 238
702 0100 MOBILIZATION L SUM 1
704 0100 FLAGGING MHR 80
704 1000 TRAFFIC CONTROL SIGNS UNIT 1034
704 1052 TYPE III BARRICADE EA 16
704 1054 SIDEWALK BARRICADE EA 4
704 1055 PEDESTRIAN LONGITUDINAL BARRICADE LF 490 704 1060 DELINEATOR DRUMS EA 142
704 1087 SEQUENCING ARROW-TYPE C EA 1
704 1500 OBLITERATION OF PVMT MK SF 43
708 1540 INLET PROTECTION-SPECIAL EA 10
709 0151 GEOSYNTHETIC MATERIAL R1 SY 1788
714 0905 PIPE CONC REINF 36IN CL III LF 46
714 6589 PIPE PVC 4IN DRAIN LF 80
722 3461 CASTING INLET TYPE 2 DOUBLE EA 2
722 3520 INLET-TYPE 2 DOUBLE EA 2
722 6140 ADJUST GATE VALVE BOX EA 3
722 6200 ADJUST MANHOLE EA 1
748 0140 CURB & GUTTER TYPE I LF 1059
750 0125 SIDEWALK CONCRETE -5IN SY 288
750 0200 CONCRETE MEDIAN PAVING SY 460
750 0210 CONCRETE MEDIAN NOSE PAVING SY 36
750 2115 DETECTABLE WARNING PANELS SF 60
754 0110 FLAT SHEET FOR SIGNS-TYPE XI REFL SHEETING SF 12
754 0206 STEEL GALV POSTS-TELESCOPING PERFORATED TUBE LF 16
762 0112 EPOXY PVMT MK MESSAGE SF 96
762 0113 EPOXY PVMT MK 4IN LINE LF 516
762 0114 EPOXY PVMT MK 6IN LINE LF 182
762 0115 EPOXY PVMT MK 8IN LINE LF 1552
762 0117 EPOXY PVMT MK 24IN LINE LF 142
762 0118 EPOXY PVMT MK CURB TOP & FACE LF 32 770 4525 REVISE LIGHTING SYSTEM EA 1 772 0001 TRAFFIC SIGNAL SYSTEM EA 1
772 9200 IT SYSTEM EA 1
8/10/2017 3:38:37 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\010-01 Basis of Estimate.doc
STATE PROJECT NO. PCN SECTIONNO.
SHEETNO.
ND SU-6-986(120)124 21589 10 1
This document was originally
issued and sealed byDavid J. KuharenkoRegistration Number
PE-8411on 08/10/2017.
The original document isstored at the City of Grand
Forks, North Dakota.
BASIS OF ESTIMATE
S. WASHINGTON ST. & 44TH AVE. S.
BASIS OF ESTIMATECommon Excavation – Type B
Excavation quantities are calculated by the end areas means method measured from top of existing ground to finished ground surface including topsoil, but excluding the concrete paving, and salvage base course.
Salvaged Base Course
Base quantities calculated using 6 inch depth and width of the new turn lane. Additional salvaged base course required to bring salvaged base course to grade due to contractor over subcutting, compaction or soil subsidence will be incidental to this bid item.
Seeding Class III and Hydro Mulch
Seeding Class III and Hydro Mulch quantities are based on the area between the turn lanes and 6 feet behind back of curb, between new sidewalks and back of curb, 2 feet adjacent to new sidewalks, as well as surrounding traffic signal equipment. Areas disturbed by the contractor outside of these areas will be repaired and seeded by the contractor at the contractor’s expense.
8/10/2017 3:39:16 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\011-1 Earthwork Tabulation.doc
STATE PROJECT NO. PCN SECTIONNO.
SHEETNO.
ND SU-6-986(120)124 21589 011 1
This document was originally
issued and sealed byDavid J. KuharenkoRegistration Number
PE-8411on 08/10/2017.
The original document isstored at the City of Grand
Forks, North Dakota.
EARTHWORK SUMMARY
S. WASHINGTON ST. & 44TH AVE. S.
Common Excavation Type B, Volume (CY)
Embankment Volume (CY)*
Station SU-6-986(120)124 Total SU-6-986(120)124 Total0+00 1+00 0 0 0 02+00 6 6 0 03+00 66 72 1 14+00 151 223 0 15+00 148 371 0 16+00 92 463 0 17+00 35 498 0 18+00 87 585 0 19+00 135 720 0 1
10+00 165 885 0 111+00 82 967 0 112+00 14 981 0 1
Totals 981 1
*Embankment quantities are based on compacted volumes
ND
SU-6-986(120)124 21589 20 1
STANDARD DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
D/2
D
D
D
D/2
TYPE 5
TYPE 4
NOTE:
ALL BARS TO BE EMBEDDED A MINIMUM OF 6"
STANDARD FILLED JOINT
STANDARD FILLED JOINT
STANDARD FILLED JOINT
NO. 4 x 24" DEFORMED
TIE BAR @ 36" O.C.
NO. 4 x 16" DEFORMED
TIE BAR @ 18" O.C.
TYPE 1
D/5
D
D/10
8" OR GREATER CONCRETE
D/2
STANDARD FILLED JOINT
D/2
D/5
D/10
D
STANDARD FILLED JOINT
NO. 4 x 16" DEFORMED
TIE BAR @ 36" O.C.
8" OR GREATER CONCRETE
7" OR LESS CONCRETE
CONCRETE CONSTRUCTION & CONTRACTION JOINTS
2/13/2017 PLATE 62.01
TYPE 3
TYPE 3
A
C
D/3
1 3/8 1/2 5/8
E
B
F
1/2 1 3/8 5/8 5/8
5/8 5/16 1 5/8 3/4 11/16
3/4 3/8 1 7/8 1 3/4
7/8 7/16 13/16
1 1/2 1 1/4 7/8
12
2 1/8
3/8
1/4
1/4
JOINT WIDTH,
INCHES
SEALANT BEAD
THICKNESS,
INCHES
MINIMUM JOINT
DEPTH,
INCHES
BACKER ROD
DIAMETER,
INCHES
BACKER ROD
PLACEMENT,
INCHES
FECBA
D/3
1/8"
HOT POUR
JOINT SEALER
NOTES:
1/8" WIDE STANDARD FILLED JOINT TO BE USED ON ALL CONCRETE CONSTRUCTION AND CONTRACTION
JOINTS UNLESS OTHERWISE NOTED
ISOLATION JOINT SEALER TO BE HOT POUR
DURING CONCRETE PAVEMENT REPAIRS OR REHABILITATIONS, JOINT WIDTH AND SEALANT TYPE TO
MATCH EXISTING JOINTS UNLESS OTHERWISE NOTED.
"D" IS DEPTH OF PAVEMENT
JOINT WIDTH TOLERANCE IS + 1/16" TO - 1/32"
THE JOINT FACES SHALL BE CLEANED BY SANDBLASTING AND DRIED BY AIR BLASTING
BACKER ROD SHALL BE CAPABLE OF WITHSTANDING SEALANT TEMPERATURES OF 400 DEGREES F.
JOINT SEALER
BACKER ROD
STANDARD FILLED JOINT
3/28/15 PLATE 62.03A
STANDARD FILLED JOINT
TYPE 6
TYPE 7
MODIFIED TYPE 7
D
D+
4"
D
D
10'-0"
1"
1"
1"
EXISTING
CONCRETE
PAVEMENT
10'-0"
D+
4"
EXPANSION BOARD
HOT POUR SEALER
EXPANSION BOARD
EXPANSION BOARD
HOT POUR SEALER
HOT POUR SEALER
CONCRETE ISOLATION JOINTS
2/13/17 PLATE 62.03
ND
SU-6-986(120)124 21589 20 2
STANDARD DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
PRIVATE SIDEWALK
6" CONCRETE DRIVEWAY
APPROACH OR ALLEY RETURN
NOTE:
DARK LINES SHOW 1/2" EXPANSION JOINT TO
BE PLACED AS SHOWN.
PRIVATE SIDEWALK WHEN PERMITTED
BY ENCROACHMENT AGREEMENT
6" CONCRETE SIDEWALK
AT VEHICULAR CROSSING
EXPANSION JOINT
EVERY 60' MAX.
CONTRACTION
JOINT @ ±5'
INTERVALS
SIDEWALK CURB RAMP
(SEE 64.07)
SIDEWALK JOINT PLAN
3/28/15 PLATE 64.03
ST
RE
ET
RA
MP
CURB
6
'
ST
RE
ET
CURB
RA
MP
2
'
1:1
2 S
LO
PE
(M
AX
)
6" CURB
6" CURB6" CURB
TOP VIEW
FRONT VIEW
CURB RAMP
DETECTABLE
WARNING
PANEL
DETECTABLE
WARNING
PANEL
SIDE VIEW
CONC. SIDEWALK OR
BIKEPATH
1/2" EXPANSION JOINT
CURB RAMP
GRASS TAPER
EDGE OF SIDEWALK
BACK OF CURB
SAWCUT (BEGIN
CURB DEPRESSION)
1/2" EXPANSION JOINT
SAWCUT
2" M
AX
VARIES
FULL WIDTH
2'
VARIES
5' MIN
CURB RAMP
3/28/15 PLATE 64.07
ND
SU-6-986(120)124 21589 20 3
STANDARD DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
TRANSVERSE JOINT
LONGITUDINAL JOINTS
LONGITUDINAL BARS SHALL
BE TIED TO EXISTING PAVEMENT
AT 24" O.C. IF NEW PAVEMENT,
LONGITUDINAL BARS SHALL
EXTEND 8" INTO ADJACENT
PANEL AT 24" O.C.
CATCH BASIN
CURB & GUTTER
PAVEMENT REINFORCING
3/28/15 PLATE 64.09A
REINFORCE PANELS DESIGNATED R
LONGITUDINAL BARS
NO. 4 @ 12" SPACING
TRANSVERSE BARS
NO. 4 @ 36" SPACING
30" 30" 15"
5'
(TYP)
5'
(TYP)
5'
(TYP)
.02FT/FT TO CURB
5"
2.5"
CROSS SECTION VIEW
PLAN VIEW
1/8" x 1 1/4" SAWED TRANSVERSE
CONTRACTION JOINT
9'6" NO. 4 DEFORMED
BARS @ 30" O.C.
1/8" x 1 1/4" SAWED LONGITUDINAL
CONTRACTION JOINT
NO. 4 DEFORMED BAR
NO. 4 DEFORMED
BARS
30"
30"
TYPICAL 10' WIDE SIDEWALK
ND
SU-6-986(120)124 21589 20 4
STANDARD DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
3"
3"
24"
8"
9"
9"
6"
ST
RU
CT
UR
E
PIPE BEDDING
4" BEDDING MATERIAL
SAND
FINISHED BERM GRADE
SEAL HOOD JOINT AND HOLE WITH
PREFORMED SEALING COMPOUND
SEAL OPENING W/ MORTAR "MUSHROOM"
MIN 3" BEYOND INLET OPENING
PAVEMENT
EDGE OF CURB AND GUTTER
BACK OF CURB - PAVING
BACK OF CURB - CASTING HOOD
2'X6'
PRECAST
CONCRETE
CATCH
BASIN
DRILL
5
8
" HOLE FOR #4 BAR
THROUGH FRONT AND SIDE
VERTICAL FLANGES OF CASTING
CAST-IN-PLACE CONCRETE
ADJUSTMENT RING. APPROX. 6"
HEIGHT. SEE NOTE 4.
INSTALL 4' X 4' X 4" EXTRUDED
POLYSTYRENE INSULATION - 40 PSI
COMPRESSIVE STRENGTH. ENTIRE
CONCRETE BASE MUST HAVE
INSULATION BENEATH IT.
3 EA NO. 4 REBAR PLACED
THROUGH VERTICAL FLANGE OF
CASTING, DRILL
5
8
" HOLES
TYPE 1 JOINT
FACE OF HOOD IS
RECESSED 6.5"
BEHIND FACE OF
CURB
BACK OF CURB
FACE OF CURB
FACE OF GUTTER
INSTALL 3 WRAPS OF 6 MIL POLY ON
CATCH BASIN STRUCTURE AND SEAL
(TAPE IN PLACE) ON ALL CATCH BASINS.
RUBBER SEAL, SEE NOTE 8
4' WIDE PRECAST
CONCRETE BASE
IF MORE THAT ONE PIPE IS TO BE INSTALLED
IN CB, PROVIDE SMOOTH INVERT WITH MIN 1"
DROP BETWEEN PIPES.
4" PVC UNDERDRAIN W/ CAST-IN
RUBBER-BOOTED CONNECTION (SIDES OF
STRUCTURE)
TYPE 7
JOINT
TYPE 7 JOINT
2'
5' M
in
6"
3"
24"
2"
2"
6.5"
20"
AP
PR
OX
.
6"
1.5"
0.5"
2"
20' TAPER
INLET-TYPE 2 AND INLET-TYPE 2 DOUBLE (TYPICAL SECTION VIEW)
INLET-TYPE 2 DOUBLE REINFORCEMENT
6"
6"
10.5"
NOTES:
1. INLET CASTING AND BARREL SHALL BE DOUBLE WRAPPED WITH 6 MIL POLY.
2. FILL INVERT TO DESIGN GRADE WITH 5 BAG CONCRETE MIX. MIN SLOPE 2"/FT.
3. USE INLET CASTING NEENAH R-3295-2 WITH TYPE R GRATE, EAST JORDAN 7031, OR APPROVED EQUAL FOR "INLET-TYPE 2
DOUBLE".
4. CONCRETE OR PLASTIC ADJUSTMENT RINGS MAY BE USED IN LIEU OF CAST-IN-PLACE CONCRETE ADJUSTMENT RING.
FOLLOW MANUFACTURERS RECOMMENDATION FOR INSTALLATION PROCEDURES.
5. BACKFILL WITH AGGREGATE BASE COURSE CL 3 OR CL 5 TO 100% DENSITY (NDDOT T 99) AROUND INLET BARREL.
6. CONSTRUCT 3' CLAY CAP BENEATH ROADWAY AGGREGATE BASE SECTION (AS SHOWN IN THE BACKFILL DETAILS) AROUND
INLET BARREL.
7. PROVIDE CONNECTIONS FOR DRAIN TILE.
8. RUBBER SEAL FOR "INLET-TYPE II DOUBLE" SHALL BE MADE OF HIGH QUALITY ETHYLENE PROPYLENE DIENE MONOMER
RUBBER WITH A MINIMUM THICKNESS OF 65 MILS. THERE SHALL BE A PREFORMED "L" SHAPED CORNER MOLDED INTO THE
TOP OF THE SEAL FOR WRAP AROUND EDGE OF CASTING FLANGE. THERE SHALL BE A 2" - 3" WIDE STRIP OF BUTYL MASTIC
ATTACHED TO THE INSIDE OF THE SIDE SECTION AT THE BOTTOM OF THE SEAL FOR SEAL TO CATCH BASIN STRUCTURE AND
AT TOP FOR SEAL TO CASTING FLANGE. INSTALL RUBBER SEAL ON THE OUTSIDE SURFACE OF THE ADJUSTMENT RINGS AND
PROVIDE COVERAGE OF ALL ADJUSTMENT RINGS.
3 PANELS - WIDTH VARIES
SEE PLAN FOR JOINT SPACING
NOTES:
1. NO PART OF PRECAST INLET STRUCTURE SHALL BE LOCATED BENEATH PAVEMENT.
2. NOTCH PAVEMENT WHEN REQUIRED. EXTEND REBAR IN GUSSETS INTO THE ADJACENT PAVEMENT AND PROVIDE
ADDITIONAL REBAR AS SHOWN.
6" CURB (TYP.)
6" CURB (TYP.)
3 JOINTS - JOINT WIDTH VARIES - SEE PLANS
7.5" CURB AT HOOD
INLET-TYPE 2 DOUBLE - FRONT VIEW
Pavement Notch
PIP
E C
ON
DU
IT
(T
YP
IC
AL)
ND
SU-6-986(120)124 21589 20 5
STANDARD DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
BACKFILL DETAIL FOR RCP PIPE
NOTE:
See Plans for Concrete, Granular and Subcut Depths
GEOSYNTHETIC
MATERIAL TYPE R1
PVC END CAP
(TYPICAL EACH SIDE)
INLET-TYPE 2 DOUBLE DRAINTILE
SEAL OPENING W/
NON-SHRINK GROUT
"MUSHROOM" MIN 3" BEYOND
INLET OPENING (TYP)
PRE CAST CONCRETE
CATCH BASIN BARREL
4" SCHEDULE 40 PVC SLEEVE WITH GASKET
& ABRASIVE EXTERIOR GROUTED IN PLACE
CONCRETE CURB
AND GUTTER
20 LF OF UNDERDRAIN PIPE
SCHEDULE 40 PVC PERFORATED 4IN
ON EACH SIDE PLACED ON FABRIC &
GRADED TO INLET. PROVIDE 4-ROW
PATTERN PERFORATIONS. PLACE
PERFORATIONS FACING DOWNWARD.
TYPICAL OF ALL INLETS. WRAP W/D3
OR D4 GEOSYNTHETIC MATERIAL AS
SPECIFIED BY NDDOT STANDARD
SPECIFICATIONS SECTION 858.01A.
CHIMNEY SEAL
(AS REQUIRED)
2" MIN
PROVIDE CAST-IN RUBBER-BOOTED
CONNECTION FOR UNDERDRAIN(S). IF
CONNECTION IS NOT FURNISHED,
CONTRACTOR TO CORE DRILL STRUCTURE
AND PROVIDE PVC TO CONCRETE ADAPTER
(SEE DETAIL BELOW).
3"
3
1
2
"
LUBRICATE GASKET AND
SLIP OVER PVC PIPE.
POSITION ADAPTER
SLEEVE IN CENTER OF CB
BARREL WALL AND GROUT
INTO PLACE WITH A
NON-SHRINK GROUT.
PVC TO CONCRETE ADAPTER
AGGREGATE
BASE
AGGREGATE BASE COURSE
CL 3 OR CL5 BEDDIGN
DENSITY AT 95% DENSITY
PIPE
PROPOSED AGGREGATE BASE
PROPOSED PAVEMENT AREA
3' CLAY CAP
98% DENSITY
AGGREGATE BASE
COURSE CL 3 OR CL 5
BACKFILL DEPTH VARIES
100% DENSITY
18" 18"
OD
6"
6"
1. MAXIMUM THICKNESS OF ANY ONE LIFT SHALL NOT EXCEED 8 INCHES LOOSE MATERIAL.
2. CLAY BACKFILL AND CLAY CAP SHALL BE COMPACTED TO SPECIFIED DENSITY AT 3% ± OF OPTIMUM MOISTURE
CONTENT.
3. TRENCH SIDE SLOPES SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY. CONTRACTOR SHALL EXCAVATE TRENCH IN
ACCORDANCE WITH OSHA AND OTHER APPLICABLE REQUIREMENTS.
4. ALL COMPACTION TESTING SHALL BE DETERMINED BY THE STANDARD PROCTOR DENSITY TEST (NDDOT T99)
5. TRENCHES BACKFILLED WITH CLAY UNDER PROPOSED ROADWAYS SHALL BE COMPACTED TO 98% DENSITY (CLAY
CAP SPECIFICATIONS)
6. REMOVE AGGREGATE CLASS AA BACKFILL FROM EXISTING TRENCHES ENCOUNTERED DURING EXCAVATION AND
CONSTRUCT 3' CLAY CAP.
7. TRENCH/UTILITY STRUCTURE BACKFILL TESTING SHALL BE TAKEN FOR EACH LAYER OF COMPACTED AGGREGATE OR
CLAY BACKFILL. A LAYER OF COMPACTED AGGREGATE OR CLAY BACKFILL IS DEFINED BY A THICKNESS OF 12
INCHES (PLACED AND COMPACTED IN 6" LIFTS). EACH SIDE OF THE PIPE SHALL BE TESTED AND CONSIDERED ITS
OWN COMPACTED LAYER. THE ENGINEER MAY REVISE THESE REQUIREMENTS TO SUIT FIELD CONDITIONS.
ND
SU-6-986(120)124 21589 20 6
STANDARD DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
NOTES:
1. INLET PROTECTION DEVICE SHALL BE MANUFACTURED TO BE RECESSED
WITHIN SPECIFIED OR EXISTING CASTING.
2. OVERFLOW TO BE SIZED AT A MINIMUM TO ACCOMMODATE THE GRATE
FLOW CAPACITY.
INLET PROTECTION
2/13/17 PLATE 69.04
GEOSYNTHETIC
MATERIAL
FILTER
RIGID FRAME
WITH RECESSED
OVERFLOW
CATCH BASIN
AREA DRAIN
CASTING
FRAME
GRATE
CURB HOOD
FLAP
MIN 6" C900 PIPE
MIN 6" WATTLE WRAPPED IN GEOTEXTILE
FABRIC OR APPROVED EQUAL
STOCKPILED MATERIAL
PIN GEOSYNTHETIC MATERIAL
TOGETHER TO
ATTACH WATTLE
TO FABRIC OR
APPROVED EQUAL
STOCKPILED MATERIAL
MIN 6" WATTLE WRAPPED
IN GEOSYNTHETIC MATERIAL OR
APPROVED EQUAL
MIN. 6" PVC PIPE
UNDER WATTLE AND
GEOSYNTHETIC MATERIAL
GEOSYNTHETIC MATERIAL
GEOSYNTHETIC MATERIAL
6" MIN
6" MIN
BERM
CURB
TRAFFIC CONE
STOCKPILE ON STREET
3/28/15 PLATE 69.10
ND
SU-6-986(120)124 21589 20 7
STANDARD DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
GUTTER
STREET
15' TYP
8'-10' T
YP
A
A
1' DEEP MIN.
BACK OF CURB
FIBER ROLL
BACK OF CURB
BELOW GRADE
PLAN VIEW
BELOW GRADE
SECTION A-A
2' DEEP MIN.
CLEAN OUT
@ 80% OF
CAPACITY
1' MIN. FREEBOARD
MAY BE UP TO 4' DEEP DEPENDING
ON CAPACITY REQ'D
ABOVE GRADE
10 MIL PLASTIC (MIN)
PROVIDE MIN.
4" FREEBOARD
CLEAN OUT
@ 80% OF
CAPACITY
WOODEN STAKES
LENGTH & WIDTH
SIMILAR TO BELOW
GRADE OPTION
SQUARE BAILS OR
OTHER APPROVED MATERIAL
E
X
I
S
T
I
N
G
G
R
O
U
N
D
O
R
R
O
A
D
W
A
Y
BARRIER FENCE
(NEED NOT BE
SILT FENCE)
FIBER ROLLS
MAX 4' SPACING
FOR STAKES
EXISTING
GROUND
BARRIER
FENCE
CONCRETE WASHOUT
3/28/15 PLATE 69.11
14/2 STRANDED S.E.O.
CABLES TO LUMINAIRE
FUSE
CONNECT USING INSULATED
SPLICE
EXTEND AT LEAST 12" OF WIRE
BEYOND HANDHOLE.
HANDHOLE
APPROVED POLE (SEE
SPECS.)
POLE GROMMET
6" FROST LOOP
GROUND WIRE
COLORED WIRES TO BE
INSTALLED IN 1-1/2"
CONDUIT WITHIN 1' OF
POLE
POLE WIRE
ND
SU-6-986(120)124 21589 20 8
STANDARD DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
LIFT OFF
HINGE
200A
METER SOCKET
LEXAN VIEW
PORT SIDE
AND REAR
VENT HOLES
UNDER ROOF
CAP
FRONT VIEW
SIDE VIEW
CONTACTORS
NOTES:
1. COMBINATION FEED POINT TO BE USED FOR TRAFFIC SIGNAL AND/OR
PEDESTRIAN CROSSING BEACON AND/OR STREET LIGHTS AS SHOWN ON
THE PLANS.
2. CABINET SHALL BE 14 GAUGE #304 STAINLESS STEEL.
3. HANDLE SHALL BE PADLOCKABLE STAINLESS STEEL WITH THREE POINT
LATCH.
4. HINGES SHALL BE LIFT-OFF.
5. INNER DEAD FRONT SHALL BE HINGED.
6. CABINET SHALL BE SUITABLE FOR SERVICE ENTRANCE.
7. ASSEMBLY SHALL BE UL508 LISTED.
8. PROVIDE CONCRETE SLAB 4" MIN. THICK, 6" WIDER THAN CABINET AT
REAR AND SIDES & 36" WIDER AT FRONT.
9. BILL OF MATERIAL:
A. 200A, 1PH., 120/240V LOAD CENTER
B. 1 - 200A 2P MAIN CIRCUIT BREAKER
C. 1 - 15A 1P BRANCH BREAKER
D. 1 - 20A 1P BRANCH BREAKER
E. 1 - 50A 1P BRANCH BREAKER
F. 4 - 60A 2P BRANCH BREAKER
G. 4 - 60A 2P MERCURY CONTRACTORS
H. TEST SWITCH
I. PHOTOCELL BASE
J. PHOTOCELL
K. 200A 2P BY-PASS METER SOCKET - STREET LIGHTS
L. 125A 2P BY-PASS METER SOCKET - TRAFFIC SIGNAL
M. 200A 2P AND 125A 2P METER
(200A METERED STREET LIGHTS)
(125A PEDESTRIAN TRAFFIC SIGNALS WITH UNMETERED OR NO
STREET LIGHTS)
N. PEDESTRIAN CROSSING CONTROLLER(PROVIDE ONLY WHEN USED
TO FEED PEDESTRIAN CROSSING)
C N
M
15/1
20/1
60/2
60/2
60/2
60/2
200/2
A
M
N
WRB
WIRING DIAGRAM
HOA
BARRIER
BEYOND
FRONT VIEW
DOOR REMOVED
PHOTO
CELL
C
C
C
N
N
N
RIGID
CONDUIT
PEDESTRIAN
CROSSING
CONTROLLER
(SEE NOTE 9N)
125A
METER
SOCKET
50/1
M
TRAFFIC SIGNAL
CONTROLLER
SEE NOTE 9M
SEE NOTE 9M
COMBINATION FEED POINT
5'
32
" M
IN
.
2" M
AX
.
4" M
IN
.
LO
WE
R R
AIL
F
OR
WA
LK
IN
G A
ID
S
SPACE TO ALLOW
FOR DRAINAGE
VERTICAL SUPPORTS
EXISTING GROUND
SIDEWALK BARRICADE
ND
SU-6-986(120)124 21589 20 9
STANDARD DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
ax
4.
4.
CR
OS
S S
LO
PE
ND
SU-6-986(120)124 21589 30 1
EXISTING TYPICAL SECTION
S. WASHINGTON ST. & 44TH AVE. S.
S. WASHINGTON STREET
(NOT TO SCALE)
PERFORATED PVC EDGEDRAIN
GEOSYNTHETIC MATERIAL
12" AGGREGATE BASE COURSE
8" PCC PAVEMENT
NORTH BOUND MAINLINE
2.1% 2.1%
8" PCC PAVEMENT
12" AGGREGATE BASE COURSE
GEOSYNTHETIC MATERIAL
PERFORATED PVC EDGEDRAIN
SOUTH BOUND MAINLINE
12' (TYP.)
MATCH LINE
SURVEY CENTER LINE
& SECTION LINE
2.1%
MEDIAN WIDTH AND SLOPE VARIES
2.1%
2' 2'
12' (TYP.)
2' 2'
12' (TYP.) 12' (TYP.)
ND
SU-6-986(120)124 21589 30 2
PROPOSED TYPICAL SECTION
S. WASHINGTON ST. & 44TH AVE. S.
NO. 4 DEFORMED BAR
18" LENGTH, 18" O.C.
1" INFLOW
11' TURN LANE
WASHINGTON ST & 44th AVE S. (TYP.)
(NOT TO SCALE)
TY
PE
3 O
R 5 JO
IN
T
TB
C S
TA
TIO
NIN
G &
P
RO
FILE
RE
MO
VA
L LIM
IT
24" LANE WIDTH VARIES12"
NO. 4 DEFORMED BAR
18" LENGTH, 18" O.C.
TYPE 3 JOINT
1" INFLOW
EXISTING PERFORATED PVC EDGE DRAIN
EXISTING GEOSYNTHETIC MATERIAL
NEW GEOSYNTHETIC MATERIAL R1
PROPOSED 8" PCC
PAVEMENT
EXISTING 8" PCC PAVEMENT
12" SALVAGED BASE COURSE
EXISTING 12" AGGREGATE BASE COURSE
FOFO
FO FOFO
FO FOFO
FO FOFO FO
FOFO
FOFO
FOFO
FOFO
UGCUGC
UG
C
UG
C
UGC
UGC
U
G
E
G
A
S
FOFO
FO
FO
FO
FO
FOFO
FO FOFO
FO FOFO
FO FOFO FO
FOFO
FOFO
FOFO
FO
UGC
FOFO
FOFOFOFO
FOFOFOFOFO
FOFOFO
FOFOFOFO
FOFOFO
S. WASHINGTON ST. NORTHBOUND
44
TH
A
VE
. S
.
44
TH
A
VE
. S
.
ND
SU-6-986(120)124 21589 40 1
REMOVALS
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 60 120
REMOVAL OF CURB & GUTTER
0+00 TO 6+50 565 LF
6+50 TO 11+80 494 LF
REMOVAL OF CONCRETE PAVEMENT
0+00 TO 6+50 355 SY
6+50 TO 11+80 254 SY
REMOVAL OF PIPE - ALL TYPES AND SIZES
0+00 TO 6+50 20 LF
6+50 TO 11+80 26 LF
REMOVAL OF INLETS
3+29 1 EA
9+19 1 EA
44
TH
A
VE
. S
.
REMOVAL OF CURB & GUTTER
REMOVAL OF CONCRETE (BIKEPATH)
REMOVE
SIDEWALK
REMOVE CURB & GUTTER
REMOVAL OF CONCRETE
(8" PCC PAVEMENT)
REMOVAL OF INLETS
(TYPE 2 - DOUBLE)
REMOVAL OF CONCRETE
(8" PCC PAVEMENT)
REMOVAL OF CURB & GUTTER
REMOVAL OF CURB &
GUTTER
REMOVAL OF CONCRETE (SIDWALK)
REMOVAL OF CURB
& GUTTER
REMOVAL OF INLETS
(TYPE 2 - DOUBLE)
REMOVE STOP SIGN (BIKEPATH)
REMOVE STOP SIGN
REMOVE STOP SIGN
OBLITERATE
EXISTING
CROSSWALK
STRIPING
REMOVE
SIGN
5.6'
OBLITERATE
EXISTING STRIPING
S. WASHINGTON ST. SOUTHBOUND
44
TH
AV
E. S
.
S. WASHINGTON ST. NORTHBOUND
S. WASHINGTON ST. SOUTHBOUND
825
826
828
830
832
834
836
838
825
826
828
830
832
834
836
838
299+20 300+00 301+00
CB 1
STA:300+12.94, 0.04L
TOC:835.69
INV: W:826.95
INV: E:826.95
14LF of 36" RCP @ 0.55%
36" RCP
INV: 826.87
36" RCP
INV: 826.87
36" RCP
INV: 826.87
6LF of 36" RCP @ 0.83%
FO
FO
FO
FO
FO
FO
FO
FO
305+00
305+26.62
CB 2
STA. 305+19.62
OFF: 0.00' L
36" STM
36" STM
9+
00
STA:9+42.05
OFF:3.25'R
STA:8+97.41
OFF:6.97'R
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
300+
26.5
7
300+00
CB 1
STA.300+12.94
OFF:-0.04' L
36" STM
36" STM
3+
00
825
826
828
830
832
834
836
838
825
826
828
830
832
834
836
838
304+40 305+00 306+00 306+20
CB 2
STA:305+19.62, 0.00L
TOC:835.97
INV: W:827.73
INV: E:827.73
20LF of 36"
RCP @ 0.55%
6LF of 36" RCP @ 0.55%
SU-6-986(120)124 21589 55 1
STORM PLAN AND PROFILE
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 5 10
Feet
0 2 4
INV. @ TIE-IN: 827.01
**FIELD VERIFY ELEVATION
INV @ TIE-IN: 827.70
(FIELD VERIFY)
EX. 36" RCP
S. W
AS
HIN
GT
ON
S
T.
SO
UT
HB
OU
ND
INSTALL 20 LF OF 4"
PERFORATED PVC
UNDERDRAIN
WITH SOCK
INSTALL 20 LF OF
4" PERFORATED
PVC
UNDERDRAIN
WITH SOCK
INSTALL 20 LF OF
4" PERFORATED
PVC UNDERDRAIN
WITH SOCK
INSTALL 20 LF OF
4" PERFORATED
PVC UNDERDRAIN
WITH SOCK
INV @ TIE-IN: 826.87
(FIELD VERIFY)
EX. 36" RCP
EX. 36" RCP
INV @ TIE-IN: 827.84
(FIELD VERIFY)
INLET-TYPE II DOUBLE 2 EA
3+30 (MAINLINE) 1 EA
9+19 (MAINLINE) 1 EA
PIPE CONC REINF 36IN CL III 46 LF
3+00 TO 3+75 (MAINLINE) 20 LF
8+50 TO 9+50 (MAINLINE) 26 LF
PIPE PVC 4IN DRAIN 80 LF
3+00 TO 3+75 (MAINLINE) 40 LF
8+50 TO 9+50 (MAINLINE) 40 LF
CASTING INLET-TYPE 2-DOUBLE 2 EA
3+30 (MAINLINE) 1 EA
9+19 (MAINLINE) 1 EA
S. W
AS
HIN
GT
ON
S
T.
NO
RT
HB
OU
ND
S. W
AS
HIN
GT
ON
S
T.
SO
UT
HB
OU
ND
S. W
AS
HIN
GT
ON
S
T.
NO
RT
HB
OU
ND
MAINLINE
ALIGNMENT
MAINLINE
ALIGNMENT
Feet
0 20 40
STORM SEWER
ALIGNMENT
STORM SEWER
ALIGNMENT
FO FOFO FO
FOFO FO
FOFO FO
FOFO
FOFO
FOFO
FOFO
FO
R
R
FOFO
FO
FO
FO
FO
FO
FO
FO FOFO FO
FOFO FO
FOFO FO
FOFO
FOFO
FOFO
FOFO
FO
R R R R
R R R R
R
R
STA:6+13.03
OFF:43.79'R
2+00
3+00
4+00
5+00
6+00
STA:5+99.53
OFF:7.84'L
STA:4+18.59
OFF:7.75'L
STA:1+75.55
OFF:12.50'R
STA:1+44.16
OFF:12.55'R
STA:5+97.18
OFF:71.09'L
SIDEWALK END:
STA:6+19.14
OFF:115.62'L
SIDEWALK END:
STA:6+20.22
OFF:118.19'R
STA:6+13.17
OFF:74.07'R
STA:6+16.70
OFF:96.65'R
STA:6+14.06
OFF:85.50'R
STA:6+12.51
OFF:71.16'L
STA:6+15.84
OFF:92.96'L
STA:6+12.55
OFF:61.04'L
STA:6+12.68
OFF:43.44'L
STA:6+28.20
OFF:14.56'R
STA:6+13.15
OFF:69.02'R
835
836
837
838
835
836
837
838
1+40 2+00 3+00 4+00 5+00 6+00 6+30
83
6.9
3
836.89
83
6.8
0
836.74
83
6.6
6
836.60
83
6.5
3
836.45
83
6.4
5
836.31
83
6.4
1
836.16
83
6.3
4
836.02
83
6.2
5
835.87
83
6.1
9
835.73
83
6.1
5
835.70
83
6.2
5
835.78
83
6.3
7
835.86
83
6.4
0
835.94
83
6.4
5
836.02
83
6.4
5
836.10
83
6.4
4
836.18
83
6.4
2
836.26
83
6.5
1
836.34
83
6.5
7
836.42
83
6.6
6
836.50
83
6.7
3
836.58
83
6.8
0
836.66
83
6.8
6
836.74
83
6.7
5
ST
A:1+
44.16
ELE
V:837.00
ST
A:3+
29.70
ELE
V:835.66
ST
A:5+
99.61
ELE
V:836.74
-0
.7
2
%
0.4
0%
Existing TBC Profile
Proposed TBC Profile
SU-6-986(120)124 21589 60 1
PAVING PLAN AND PROFILE
STA 1+40 TO 6+50
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 40 80
Feet
0 4 8
CONCRETE MEDIAN PAVING -
5IN COLORED TERRACOTTA RED
8" PCC PAVEMENT
INSTALL SIDEWALK CONCRETE- 5IN
SIDEWALK
CONCRETE - 5IN
COMMON EXCAVATION TYPE C
1+40 TO 6+50 343 CY
SALVAGED BASE COURSE
1+40 TO 6+50 256 CY
GEOSYNTHETIC MATERIAL R1
1+40 TO 6+50 834 SY
SIDEWALK CONCRETE - 5IN
1+40 TO 6+50 144 SY
CONCRETE MEDIAN PAVING
1+40 TO 6+50 130 SY
CONCRETE MEDIAN NOSE PAVING
1+40 TO 6+50 16 SY
CURB & GUTTER TYPE I
1+40 TO 6+50 565 LF
DETECTABLE WARNING PANELS
6+17 10 SF
6+18 10 SF
6+33 20 SF
8IN NON-REINF CONCRETE PAVEMENT CL AE
1+40 TO 6+50 664 SY
8IN REINF CONCRETE PAVEMENT CL AE
1+40 TO 6+50 76 SY
SIDEWALK CONCRETE - 5IN
Existing Pavement Edge Profile
Feet
0 20 40
10'
5'
5'
835
836
837
838
835
836
837
838
6+80 7+00 8+00 9+00 10+00 11+00 11+40
83
7.0
0
83
7.2
1
837.20
83
6.9
0
836.68
83
6.8
6
836.60
83
6.8
2
836.52
83
6.7
1
836.44
83
6.6
4
836.36
83
6.5
6
836.28
83
6.5
2
836.20
83
6.4
6
836.12
83
6.3
7
836.04
83
6.4
0
835.97
83
6.4
1
836.08
83
6.4
7
836.18
83
6.6
0
836.29
83
6.7
0
836.39
83
6.7
3
836.50
83
6.7
8
836.60
83
6.8
7
836.70
83
6.9
6
836.81
83
7.0
8
836.91
83
7.1
3
837.02
ST
A:9+
19.10
ELE
V:835.97
ST
A:11+
32.92
ELE
V:837.09
ST
A:7+
20.17
ELE
V:837.21
STA:7+12.51
ELEV:836.80
F
O
F
O
FOFOFOFOFOFOFO
FOFOFOFO
FOFOFO
FOFOFO
FOFOFOFO
FO
RR
R
R
R
R
R R
R
R
RR
RR
STA:7+05.31
OFF:43.70'R
STA:6+80.41
OFF:73.17'R
7+00
8+00
9+00
10+00
11+00
STA:7+05.35
OFF:72.95'R
STA:6+91.51
OFF:15.43'L
STA:7+19.84
OFF:14.40'R
STA:7+20.01
OFF:7.09'R
STA:8+96.99
OFF:7.00'R
STA:11+24.87
OFF:11.99'L
STA:11+32.92
OFF:9.69'L
STA:9+13.00
OFF:27.48'L
STA:9+26.06
OFF:27.46'L
Existing TBC Profile
0.5
2%
-0.4
0%
SU-6-986(120)124 21589 60 2
PAVING PLAN AND PROFILE
STA 6+50 TO 11+30
S. WASHINGTON ST. & 44TH AVE. S.
8" PCC PAVEMENT
COMMON EXCAVATION TYPE C
6+50 TO 11+33 443 CY
SALVAGED BASE COURSE
6+50 TO 11+33 278 CY
GEOSYNTHETIC MATERIAL R1
6+50 TO 11+33 954 SY
SIDEWALK CONCRETE - 5IN
6+50 TO 11+33 144 SY
CONCRETE MEDIAN PAVING
6+50 TO 11+33 330 SY
CONCRETE MEDIAN NOSE PAVING
6+50 TO 11+33 20 SY
CURB & GUTTER TYPE I
6+50 TO 11+33 494 LF
DETECTABLE WARNING PANELS
6+82 10 SF
7+00 10 SF
8IN NON-REINF CONCRETE PAVEMENT CL AE
6+50 TO 11+33 691 SY
8IN REINF CONCRETE PAVEMENT CL AE
6+50 TO 11+33 162 SY
Existing Pavement Edge Profile
Feet
0 40 80
Feet
0 4 8
Feet
0 20 40
Proposed TBC Profile
CONCRETE MEDIAN PAVING -
5IN COLORED TERRACOTTA RED
SIDEWALK
CONCRETE - 5IN
5'
FOFO
FO FOFO
FOFO
FOFO
FOFO
FO
FOFOFO
FOFOFO
FOFO
FOFOFOFO
FO
FO
FO
FO
FO
FOFO
FO FOFO
FOFO
FOFO
FOFO
FO
ND
SU-6-986(120)124 21589 76 1
TEMPORARY EROSION CONTROL
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 60 120
INLET PROTECTION - SPECIAL
STA 3+29 4 EA
STA 6+45 2 EA
STA 6+73 2 EA
STA 9+19 4 EA
S. WASHINGTON ST.
44
TH
A
VE
. S
.
INLET PROTECTION - SPECIAL
INLET PROTECTION - SPECIAL
INLET PROTECTION - SPECIAL
INLET PROTECTION - SPECIAL
PROTECT
DOWNSTREAM
INLET (2)
PROTECT
DOWNSTREAM
INLET (2)
ND
SU-6-986(120)124 21589 77 1
PERMANENT EROSION CONTROL
STA 1+00 TO 6+50
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 40 80
SEEDING CLASS lll
1+00 to 6+50 0.05 ACRE
HYDROMULCH
1+00 TO 6+50 0.05 ACRE
S. WASHINGTON ST. SOUTHBOUND
44
TH
A
VE
. S
.
INSTALL SEEDING CLASS III
AND HYDROMULCH
S. WASHINGTON ST. NORTHBOUND
44
TH
A
VE
. S
.
ND
SU-6-986(120)124 21589 77 2
PERMANENT EROSION CONTROL
STA 6+50 TO 11+50
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 40 80
SEEDING CLASS lll
6+50 to 11+50 0.02 AC
HYDROMULCH
6+50 to 11+50 0.02 AC
S. WASHINGTON ST.
44
TH
A
VE
. S
.
INSTALL HYDROMUCLH
INSTALL HYDROMUCLH
44
TH
A
VE
. S
.
STA:7+05.35
OFF:72.95'R
STA:6+80.41
OFF:73.17'R
STA:7+05.31
OFF:43.70'R
DETECTABLE
WARNING PANEL
STA:6+81.80
OFF:68.16'R
DETECTABLE
WARNING PANEL
STA:7+00.32
OFF:46.14'R
STA:6+13.03
OFF:43.79'R
STA:6+13.17
OFF:74.08'R
STA:6+14.06
OFF:85.51'R
STA:6+16.70
OFF:96.66'R
STA:6+19.26
OFF:107.29'R
STA:6+20.22
OFF:118.19'R
DETECTABLE
WARNING PANEL
STA:6+18.04
OFF:46.54'R
ND
SU-6-986(120)124 21589 80 1
ADA RAMP DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
12:1 MAX
NE QUADRANT STA 7+00
S. WASHINGTON ST. & 44TH AVE. S.
SE QUADRANT STA 6+18
S. WASHINGTON ST. & 44TH AVE. S.
12:1 MAX
12:1 M
AX
44TH AVE. S.
S. W
AS
HIN
GT
ON
S
T.
NO
RT
HB
OU
ND
L
AN
E
S. W
AS
HIN
GT
ON
S
T.
NO
RT
HB
OU
ND
L
AN
E
44TH AVE. S.
2%
2%
2%
2'
CURB
TRANSITION
2'
CURB
TRANSITION
2'
CURB
TRANSITION
2'
CURB
TRANSITION
2'
CURB
TRANSITION
2'
CURB
TRANSITION
PROPOSED
SIGNAL
STANDARD
(S5)
PROPOSED
SIGNAL
STANDARD
(S3)
PROPOSED PEDESTRIAN PUSH BUTTON
PROPOSED
PEDESTRIAN PUSH
BUTTON
PROPOSED PEDESTRIAN PUSH BUTTON
PROPOSED
PEDESTRIAN
PUSH BUTTON
PROPOSED CONCRETE
SIDEWALK - 5IN
PROPOSED
CONCRETE
SIDEWALK - 5IN
Feet
0 10 20
PROPOSED
SIGNAL
STANDARD
(S4)
PROPOSED PULL BOX
STA:6+12.53
OFF:71.11'L
STA:6+13.39
OFF:82.20'L
STA:6+15.87
OFF:93.03'L
STA:6+18.41
OFF:104.21'L
STA:6+19.19
OFF:115.64'L
STA:5+97.18
OFF:71.09'L
DETECTABLE
WARNING PANEL
STA:6+17.64
OFF:45.72'L
DETECTABLE
WARNING PANEL
STA:6+33.21
OFF:61.01'L
DETECTABLE
WARNING PANEL
STA:6+33.21
OFF:71.06'L
ND
SU-6-986(120)124 21589 80 2
ADA RAMP DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
SW QUADRANT STA 6+18
S. WASHINGTON ST. & 44TH AVE. S.
12:1 M
AX
12:1 MAX
44TH AVE. S.
S. W
AS
HIN
GT
ON
S
T.
SO
UT
HB
OU
ND
L
AN
E
2% MAX
2%
2
'
2
'
2'
CURB
TRANSITION
2'
CURB
TRANSITION
PROPOSED SIGNAL
STANDARD (S2)
PROPOSED
PEDESTRIAN
PUSH BUTTON
PROPOSED
PEDESTRIAN
PUSH BUTTON
Feet
0 10 20
PROPOSED
SIGNAL
STANDARD
(S1)
4.5
'
PROPOSED
PULL
BOX
FO FOFO
FO FOFO FO
FOFO FO
FOFO
FOFO
FOFO
FOFO
FOFO
UGCUGC
UGC
UGC
R
R
FOFOFO
FO
FO
FO
FO
FO
FO
FO FOFO
FO FOFO FO
FOFO FO
FOFO
FOFO
FOFO
FOFO
FOFO
R R R R
R R R R
R
R
F
O
F
O
FOFOFOFOFOFOFO
FOFO
FOFOFO
FOFO
FOFOFO
FOFOFO
FOFO
RR
R
R
R
R
R R
RR
RR
RR
ND
SU-6-986(120)124 21589 90 1
JOINT LAYOUT
S. WASHINGTON ST. & 44TH AVE. S.
S. WASHINGTON ST. SOUTHBOUND
44
TH
A
VE
. S
.
44
TH
A
VE
. S
.
MATCH
EXISTING
JOINT
S. WASHINGTON ST. NORTHBOUND
44
TH
A
VE
. S
.
44
TH
A
VE
. S
.
S. WASHINGTON ST. SOUTHBOUND
S. WASHINGTON ST. NORTHBOUND
Feet
0 40 80
MATCH INTO
EXISTING JOINTS
MATCH INTO
EXISTING JOINTS
11.2' (TYP.)
MAINLINE ALIGNMENT
MAINLINE ALIGNMENT
11.3' (TYP.)
SECTION SHEET
NO. NO.
100 1
D3-36 36"x6" STREET NAME SIGN (Sign and installation only) 6 54"x12" NEXT __ MILES (Mounted on warning sign post)
G20-1-60 60"x24" ROAD WORK NEXT __ MILES 34 48"x48" WORKERS SYMBOL
G20-1b-60 60"x24" WORK IN PROGRESS/ NO WORK IN PROGRESS (Sign and installation only) 26 48"x48" FRESH OIL
G20-2-48 48"x24" END ROAD WORK 11 19 209 48"x48" ROAD MACHINERY AHEAD or __ FT
G20-4-36 36"x18" PILOT CAR FOLLOW ME (Mounted to back of pilot car) 18 48"x48" SHOULDER WORK
G20-10-108 108"x48" CONTRACTOR SIGN 64 48"x48" RIGHT or LEFT SHOULDER CLOSED
G20-50a-72 72"x36" ROAD WORK NEXT __ MILES RT & LT ARROWS 37 48"x48" RIGHT or LEFT SHOULDER CLOSED AHEAD or __ FT.
G20-52a-72 72"x24" ROAD WORK NEXT __ MILES RT or LT ARROW 30 48"x48" SURVEY CREW AHEAD
G20-55-96 96"x48" SPEED LIMIT ENFORCED - MINIMUM FEE $80 WHEN WORKERS PRESENT 59 48"x48" BRIDGE PAINTING AHEAD or __ FT.
M1-1-36 36"x36" INTERSTATE ROUTE MARKER (Post and installation only) 10 48"x48" MATERIAL ON ROADWAY
M1-4-24 24"x24" U.S. ROUTE MARKER (Post and installation only) 10 48"x48" FRESH OIL LOOSE ROCK
M1-5-24 24"x24" STATE ROUTE MARKER (Post and installation only) 10 24"x24" TAKE TURNS (6" D letters) (Mounted on stop sign post)
M3-1-24 24"x12" NORTH (Mounted on route marker post) 7
M3-2-24 24"x12" EAST (Mounted on route marker post) 7
M3-3-24 24"x12" SOUTH (Mounted on route marker post) 7
M3-4-24 24"x12" WEST (Mounted on route marker post) 7
M4-8-24 24"x12" DETOUR (Mounted on route marker post) 7
M4-9-30 30"x24" DETOUR ARROW RIGHT or LEFT/AHD AND RT or LT 15
M4-10-48 48"x18" DETOUR ARROW RIGHT or LEFT 23
M5-1-21 21"x15" ARROW AHD AND RT or LT(Mounted on route marker post) 7
M5-2-21 21"x15" ARROW AHD UP & RT or LT (Mounted on route marker post) 7
M6-1-21 21"x15" ARROW RT or LT (Mounted on route marker post) 7
M6-2-21 21"x15" ARROW UP & RT or LT (Mounted on route marker post) 7
M6-3-21 21"x15" ARROW AHD (Mounted on route marker post) 7
R1-1-48 48"x48" STOP 32
R1-1a-18 18"x18" STOP and SLOW PADDLE Back to Back 2 5 10
R1-2-60 60"x60" YIELD 29
R2-1-48 48"x60" SPEED LIMIT __ 3 39 117
R2-1a-24 24"x18" MINIMUM FEE $80 (Mounted on Speed Limit post) 3 10 30 SPECIAL SIGNS
R3-5R-30 30"x36" RIGHT TURN ONLY 2 18 36 48"x12" NORTHBOUND WASHINGTON ONE LANE
R3-7-48 48"x48" LEFT or RIGHT LANE MUST TURN LEFT or RIGHT 1 35 35
R4-1-48 48"x60" DO NOT PASS 39
R4-7-48 48"x60" KEEP RIGHT SYMBOL 39
R5-1-48 48"x48" DO NOT ENTER 35
R6-1-36 36"x12" ONE WAY RIGHT or LEFT 13
R7-1-12 12"x18" NO PARKING 11
R9-9-24 24"x12" SIDEWALK CLOSED 4 4 16
R10-6-24 24"x36" STOP HERE ON RED 16
R11-2-48 48"x30" ROAD CLOSED 28
R11-2a-48 48"x30" STREET CLOSED 28
R11-3a-60 60"x30" ROAD CLOSED __ MILES AHEAD LOCAL TRAFFIC ONLY 31
R11-3c-60 60"x30" STREET CLOSED __ MILES AHEAD LOCAL TRAFFIC ONLY 31
R11-4a-60 60"x30" STREET CLOSED TO THRU TRAFFIC 31
W1-3-48 48"x48" RIGHT or LEFT SHARP REVERSE CURVE ARROW 35
W1-4-48 48"x48" RIGHT or LEFT REVERSE CURVE ARROW 35
W1-4b-48 48"x48" DOUBLE RIGHT or LEFT REVERSE CURVE ARROW 35
W1-6-48 48"x24" LARGE ARROW 26 TRAFFIC CONTROL SIGNS TOTAL UNITS
W3-1-48 48"x48" STOP AHEAD SYMBOL 35
W3-3-48 48"x48" SIGNAL AHEAD SYMBOL 35
W3-4-48 48"x48" BE PREPARED TO STOP 35
W3-5-48 48"x48" SPEED REDUCTION AHEAD 2 35 70
W4-2-48 48"x48" RIGHT or LEFT LANE TRANSITION SYMBOL 1 35 35
W4-7R-48 48"x48" THRU TRAFFIC MERGE RIGHT 1 28 28
W5-1-48 48"x48" ROAD NARROWS 35
W5-8-48 48"x48" THRU TRAFFIC RIGHT LANE 35
W5-9-48 48"x48" ROAD WORK TRAFFIC ONLY DOWN & LT or RT ARROW 35
W6-3-48 48"x48" TWO WAY TRAFFIC SYMBOL 35
W8-1-48 48"x48" BUMP 35
W8-3-48 48"x48" PAVEMENT ENDS 35
W8-7-48 48"x48" LOOSE GRAVEL 35
W8-9a-48 48"x48" SHOULDER DROP-OFF 35
W8-11-48 48"x48" UNEVEN LANES 35
W8-12-48 48"x48" NO CENTER STRIPE 35
W8-53-48 48"x48" TRUCKS ENTERING HIGHWAY 35
W8-54-48 48"x48" TRUCKS ENTERING AHEAD or __ FT. 35
W8-55-48 48"x48" TRUCKS CROSSING AHEAD or __ FT. 35
W8-56-48 48"x48" TRUCKS EXITING HIGHWAY 35
W9-3a-48 48"x48" CENTER LANE CLOSED SYMBOL 35
W12-1-48 48"x48" DOUBLE ARROW 1 28 28
W12-2-48 48"x48" LOW CLEARANCE SYMBOL 35
W13-1-24 24"x24" __ MPH ADVISORY SPEED PLATE (Mounted on warning sign post) 11
W13-4-48 48"x60" RAMP ARROW 39
W14-3-48 48"x36" NO PASSING ZONE 23
W20-1-48 48"x48" ROAD WORK AHEAD or _FT or _ MILE 9 35 315
W20-2-48 48"x48" DETOUR AHEAD or __ FT 35
W20-3-48 48"x48" ROAD or STREET CLOSED AHEAD or __ FT. 35
W20-4-48 48"x48" ONE LANE ROAD AHEAD or __ FT. 35
W20-5-48 48"x48" RIGHT or LEFT LANE CLOSED AHEAD or __ FT. 1 35 35
W20-7a-48 48"x48" FLAGGING SYMBOL 2 35 70
W20-7k-24 24"x18" __ FEET (Mounted on warning sign post) 10
W20-8-48 48"x48" STREET CLOSED 35
W20-51-48 48"x48" EQUIPMENT WORKING 35
UNITS
SUB
TOTAL
11
This document was
originally issued
and sealed by
David J. Kuharenko,
Registration Number
PE-8411,
on 8/10/17 and the
original document
is stored at the City of Grand
Forks, North Dakota.
43
16
490
1
Traffic Control Devices List
35
35
NOTE:
If additional signs are
required, units will be
calculated using the formula
from Section III-19.06 of the
Design Manual.
http://www.dot.nd.gov/
26
1034
STATE
ND
PROJECT NO.
35
12
SU-6-986(120)124
UNITS
PER
AMOUNT
35
35
35
AMOUNT
REQUIRED
SIGN
SIZE
W20-52-54
DESCRIPTION
35
35
35
35
UNITS
PER
AMOUNT
UNITS
SUB
TOTAL
SIGN
NUMBER
W21-6a-48
W21-50-48
SIGN
NUMBER
SIGN
SIZEDESCRIPTION
AMOUNT
REQUIRED
W21-2-48
W21-3-48
W21-5-48
W21-5a-48
W21-51-48
W22-8-48
W21-1a-48
W21-5b-48
EACH
4
142
EACH
EACH
EACH
EACH
EACH
EACH
EACH
QUANTITY
80
772-2110 FLASHING BEACON - POST MOUNTED
704-1055
704-1060
704-1065
704-1067
704-1085
DELINEATOR
EACH
EACH
EACH
LF
EACH
EACH
EACH
EACH
704-1044
704-1043
ATTENUATION DEVICE-TYPE B-55
TUBULAR MARKERS
RAISED PAVEMENT MARKERS
SHORT TERM 4IN LINE - TYPE R
EACH
EACH
SF
LF
EACH
LF
EACH
EACH
SPEC & CODE
DESCRIPTION
FLAGGING704-0100 MHR
704-1000
SPEC &
CODEUNIT
762-0430
TYPE I BARRICADES
TYPE II BARRICADES
SHORT TERM 4IN LINE - TYPE NR
SEQUENCING ARROW PANEL - TYPE B
SEQUENCING ARROW PANEL - TYPE C
SEQUENCING ARROW PANEL - TYPE C - CROSSOVER
TYPE B FLASHERS
OBLITERATION OF PVMT MK
PORTABLE PRECAST CONCRETE MED BARRIER
PRECAST CONCRETE MED BARRIER - STATE FURNISHED
704-1086
704-1087
704-1088
704-1095
DELINEATOR DRUMS
TRAFFIC CONES
704-3510
704-1054 SIDEWALK BARRICADE
FLEXIBLE DELINEATORS
VERTICAL PANELS - BACK TO BACK
SEQUENCING ARROW PANEL - TYPE A
704-1041
PEDESTRIAN LONGITUDINAL BARRICADE
LF
762-0200
762-0420
ATTENUATION DEVICE-TYPE B-65
ATTENUATION DEVICE-TYPE B-70
EACH
704-1500
704-3501
704-1070
704-1072
704-1081
704-1050
704-1051
704-1052 TYPE III BARRICADES
8/10/2017 3:41 PM S:\7591 Permanent Traffic Signal at S Wash & 44th Ave S\Design\Sheets in Word\100-Traffic Control Device List VERSION: 4.4.2008
ROAD
WORK
AHEAD
ROAD
WORK
AHEAD
SPEED
LIMIT
25
MINIMUM
FEE
$80
SPEED
LIMIT
25
LEFT LANE
MUST
TURN LEFT
W20-1-48
W3-5-48
W20-1-48
R3-7L-48
W12-1-48
R2-1a-24
W4-2R-48
R2-1-48
ROAD
WORK
AHEAD
W20-1-48
NB
WASHINGTON
NB
ONE LANE
WASHINGTON
ONE LANE
ROAD WORK
END
G20-2a-48
ROAD WORK
END
G20-2a-48
ROAD WORK
END
G20-2a-48
ROAD
WORK
AHEAD
W20-1-48
ROAD WORK
END
G20-2a-48
MINIMUM
FEE
$80
SPEED
LIMIT
25
R2-1a-24
R2-1-48
ROAD WORK
END
G20-2a-48
ND
SU-6-986(120)124 21589 100 2
S. WASHINGTON ST. & 44TH AVE. S.
WORK ZONE TRAFFIC CONTROL
Feet
0 150 300
180'
100'
100'
180'
BAG EXISTING
SPEED LIMIT SIGN
EXISTING
SPEED LIMIT 40
47
TH
A
VE
. S
.
S. WASHINGTON ST. NORTHBOUND
S. WASHINGTON ST. SOUTHBOUND
47
TH
A
VE
. S
.
S. 11TH ST.
46
TH
A
VE
. S
.
S. 11TH ST.
48
TH
A
VE
. S
.
48
TH
A
VE
. S
.
TYPE III BARRICADES
NOTE:
ALL SIGNS CONFLICTING WITH THIS PLAN SHALL BE BAGGED
L
ROAD WORK
END
G20-2a-48
ROAD WORK
END
G20-2a-48
ROAD
WORK
AHEAD
N
W20-1-48
ROAD
WORK
AHEAD
W20-1-48
ON Y
STOP
O LY
STOP
R3-5R
Existing
Stop Sign
Existing
Stop
Sign
R3-5R
ROAD WORK
END
G20-2a-48
ROAD
WORK
AHEAD
W20-1-48
W20-7-48
W20-7-48
ND
SU-6-986(120)124 21589 100 3
S. WASHINGTON ST. & 44TH AVE. S.
WORK ZONE TRAFFIC CONTROL
Feet
0 100 200
100'
100'
ARROW BOARD
44
TH
A
VE
. S
.
25' TYP.
42
ND
A
VE
. S
.
TYPE III BARRICADE (12)
BAG EXISTING
SPEED LIMIT SIGN
46
TH
A
VE
. S
.
TYPE III
BARRICADES (3)
180' TAPER
MA
TC
HL
IN
E
NOTE:
ALL SIGNS CONFLICTING WITH THIS PLAN SHALL BE BAGGED
COVER WHEN NOT IN USE
COVER WHEN NOT IN USE
ROAD WORK
END
G20-2a-48
ROAD
WORK
AHEAD
SPEED
LIMIT
25
W20-1-48
W3-5-48
MINIMUM
FEE
$80
SPEED
LIMIT
25
R2-1a-24
W4-2L-48
R2-1-48
W20-5-48
LANE
CLOSED
AHEAD
LEFT
ROAD WORK
END
G20-2a-48
ROAD
WORK
AHEAD
W20-1-48
ROAD WORK
END
G20-2a-48
ROAD
WORK
AHEAD
W20-1-48
ND
SU-6-986(120)124 21589 100 4
S. WASHINGTON ST. & 44TH AVE. S.
WORK ZONE TRAFFIC CONTROL
Feet
0 150 300
180' 180'350' 180' 180'
EXISTING
SPEED LIMIT 40
S. WASHINGTON ST. NORTHBOUND
S. WASHINGTON ST. SOUTHBOUND
40
TH
A
VE
. S
.
38
TH
A
VE
. S
.
SOUTH 11TH ST
180' TAPER
NOTE:
ALL SIGNS CONFLICTING WITH THIS PLAN SHALL BE BAGGED
ND
SU-6-986(120)124 21589 100 5
PEDESTRIAN DETOUR
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 40 80
SIDEWALK
CLOSED
R9-9-24
ON SIDEWALK BARRICADE
SIDEWALK
CLOSED
R9-9-24
ON SIDEWALK BARRICADE
SIDEWALK
CLOSED
R9-9-24
ON SIDEWALK BARRICADE
SIDEWALK
CLOSED
R9-9-24
ON SIDEWALK BARRICADE
76LF OF PEDESTRIAN
LONGITUDINAL BARRICADE
97 LF OF PEDESTRIAN
LONGITUDINAL BARRICADE
22LF OF PEDESTRIAN
LONGITUDINAL BARRICADE
PROPOSED CONCRETE
DELINEATOR DRUM
PEDESTRIAN LONGITUDINAL
BARRICADE
100LF PEDESTRIAN
LONGITUDINAL BARRICADE
NOTE:
WHEN PEDESTRIAN LONGITUDINAL BARRICADES
ARE USED IN GRASS, THE FOLLOWING WILL BE
REQUIRED:
1. CONSTRUCT AN EVEN, HARD SURFACE WITH
MATERIAL SUCH AS WOOD OR METAL
BETWEEN PEDESTRIAN LONGITUDINAL
BARRICADES.
2. COAT THE SURFACE WITH A NON-SLIP, SKID
RESISTANT MATERIAL.
3. INCLUDE ALL COSTS TO FURNISH, MAINTAIN
AND REMOVE HARD SURFACE AND RESTORE
GRASS IN THE COSTS FOR THE BID ITEM
"PEDESTRIAN LONGITUDINAL BARRICADE".
STA:3+06.40
OFF:14.64'R
STA:3+14.53
OFF:10.71'R
BEGIN TAPER
STA:4+19.08
OFF:5.25'R
STA:4+50.15
OFF:3.56'R
STA:5+65.38
OFF:3.49'R
CENTER OF 24" STOPBAR
STA:6+07.51
OFF:39.25'R
STA:6+12.39
OFF:41.27'L
STA:3+06.45
OFF:26.77'R
ND
SU-6-986(120)124 21589 120 1
MARKING
STA 3+00 TO 6+20
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 30 60
S. WASHINGTON ST.
S. WASHINGTON ST.
44
TH
A
VE
. S
.
EPOXY PVMT MK 4IN LINE
3+00 to 6+20 80 LF
EPOXY PVMT MK 8IN LINE
3+00 to 6+20 776 LF
EPOXY PVMT MK 24IN LINE
3+00 to 6+20 45 LF
EPOXY PVMT MK-MESSAGE
3+14 16 SF
4+50 16 SF
5+65 16 SF
EPOXY PVMT MK CURB TOP & FACE
5+90 TO 6+20 12 LF
12
'1
2.5
'9
'1
2.5
'5
.6
'2
8'
9'
EPOXY PVMT MK
6IN LINE - WHITE
EPOXY PVMT MK
24IN LINE - WHITE
EPOXY PVMT MK 8IN LINE - WHITE
EPOXY PVMT MK
CURB TOP & FACE -
YELLOW
EPOXY PVMT MK MESSAGE - WHITE
15'
4' 6'
EPOXY PVMT MK
4IN LINE - WHITE
30'
(TYP.)
10'
(TYP.)
10'
(TYP.)
STA:6+17.88
OFF:43.44'L
BEGIN 4" EPOXY PVMT MK
4IN LINE - DOUBLE YELLOW
STA:6+61.33
OFF:179.83'R
CENTER OF STOPBAR
STA:6+59.23
OFF:78.87'R
STA:6+38.39
OFF:68.29'R
STA:6+39.87
OFF:73.78'R
BEGIN BEGIN 4" EPOXY PVMT MK
4IN LINE - DOUBLE YELLOW
STA:6+59.79
OFF:155.50'L
STA:6+60.56
OFF:75.58'L
STA:6+39.88
OFF:71.33'L
STA:6+35.49
OFF:60.78'L
STA:6+93.71
OFF:60.75'L
ND
SU-6-986(120)124 21589 120 2
MARKING
STA 6+20 TO 6+95
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 30 60
S. W
AS
HIN
GT
ON
S
T.
44TH AVE. S.
EPOXY PVMT MK PAINTED 4IN LINE
6+20 to 6+95 356 LF
EPOXY PVMT MK 6IN LINE
6+20 to 6+95 182 LF
EPOXY PVMT MK PAINTED 24IN LINE
6+20 to 6+95 40 LF
20
'2
0'
EPOXY PVMT MK
6IN LINE - WHITE
EPOXY PVMT MK
24IN LINE - WHITE
4' 11'
EPOXY PVMT MK
6IN LINE - WHITE
EPOXY PVMT MK
24IN LINE - WHITE
4'6'
15
'1
5'
CENTER OF 24" STOP BAR
STA:7+10.75
OFF:5.10'R
STA:7+39.24
OFF:3.71'L
STA:7+00.06
OFF:43.89'R
STA:7+05.56
OFF:41.29'R
STA:8+71.99
OFF:3.42'L
BEGIN TAPER
STA:8+96.44
OFF:6.00'L
STA:10+11.73
OFF:15.60'L
STA:10+11.73
OFF:27.43'L
STA:10+11.52
OFF:11.86'L
ND
SU-6-986(120)124 21589 120 3
MARKING
STA 7+07 TO 10+50
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 30 60
S. WASHINGTON ST.
44
TH
A
VE
. S
.
EPOXY PVMT MK 4IN LINE
6+95 to 10+12 80 LF
EPOXY PVMT MK 8IN LINE
6+95 to 10+12 776 LF
EPOXY PVMT MK 24IN LINE
6+95 to 10+12 57 LF
EPOXY PVMT MK-MESSAGE
7+39 16 SF
8+71 16 SF
10+11 16 SF
EPOXY PVMT CURB TOP & FACE
6+95 to 10+12 20 LF
EPOXY PVMT MK
CURB TOP & FACE
EPOXY PVMT MK
MESSAGE - WHITE
6' 4'
EPOXY PVMT MK
4IN LINE - WHITE
EPOXY PVMT MK
6IN LINE - WHITE
EPOXY PVMT MK
24IN LINE - WHITE
28
'
5.4
'
13
'9
.6
'1
2'
12
'1
3'
15'
EXISTING PAVEMENT
MARKING TO REMAIN
30'
(TYP.)
10'
(TYP.)
10'
(TYP.)
EPOXY PVMT MK
8IN LINE - WHITE
FOFO
FOFO
UG
C
UGC
UGCUGC
UGC
UG
C
UG
C
UGCUGC
UGC
UGC
UG
E
UGE
GA
S
GAS
FOFO
FOFOFO
FOFOFO
FOFOFOFO
FOFOFO
FOFO
FOFO
FOFO
FOFO
FOFO
FO
STREET LIGHT PULL BOX #1
STA:5+92.97
OFF:55.25'L
STREET LIGHT PULL BOX #3
STA:7+22.79
OFF:55.43'L
STREET LIGHT PULL BOX #2
STA:5+77.16
OFF:54.24'R
STA:6+24.71
OFF:77.17'R
STA:7+08.83
OFF:56.95'R
STA:7+01.67
OFF:74.55'L
REMOVE STREET LIGHT
STA:7+19.22
OFF:54.24'R
REMOVE STREET LIGHT
STA:5+92.97
OFF:55.25'L
STA:6+09.76
OFF:56.83'L
ND
SU-6-986(120)124 21589 140 1
LIGHTING LAYOUT
SOUTH WASHINGTON ST. & 44TH AVE. S.
Feet
0 40 80
STREET LIGHT #6 & #7
MOUNTED ON
TRAFFIC SIGNAL
STREET LIGHT #5 & #8
MOUNTED ON TRAFFIC
SIGNAL
TIE NEW CONDUCTORS INTO
EXISTING STREET LIGHT #1
TO REMAIN
TIE NEW CONDUCTORS
INTO EXISTING STREET
LIGHT #2 TO REMAIN
TIE NEW
CONDUCTOR
INTO EXISTING
STREET LIGHT #3
TO REMAIN
TIE
CONDUCTORS
INTO EXISTING
STREET LIGHT #4
TO REMAIN
NEW CONDUCTOR IN
EXISTING CONDUIT
NEW CONDUCTORS IN
EXISTING CONDUIT
REVISE LIGHTING SYSTEM
3+00 TO 10+00 1 EA
NEW CONDUCTORS IN
NEW CONDUIT
REMOVE EXISTING ELECTRICAL WIRE IN CONDUIT
REMOVE EXISTING ELECTRICAL WIRE IN CONDUIT
REMOVE EXISTING CONDUCTORS IN CONDUIT
NEW CONDUCTOR IN EXISTING CONDUIT
EXTEND/RELOCATE EXISTING CONDUITS TO NEW STREETLIGHT LOCATION
NEW CONDUCTORS IN NEW CONDUIT
NOTE:
ITEMS SHOWN ABOVE ARE FOR INFORMATIONAL PURPOSES ONLY. CONTRACTOR
SHALL PROVIDE ALL MATERIALS, LABOR, AND EQUIPMENT NECESSARY FOR THE
LIGHTING SYSTEM TO BE FULLY OPERATIONAL AS SHOWN ON PLANS.
ELECTRICAL WIRE REMOVAL 1010 LF
STREET LIGHT REMOVAL 2 EA
INSTALL NEW CONDUIT 180 LF
INSTALL NEW ELECTRICAL WIRE 1010 LF
INSTALL NEW STREET LIGHTS 4 EA
FOFO
FOFO
FO
FOFO
FOFOFOFO
FOFO
FOFOFO
FOFO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FOFO
FOFO
FO
PULL BOX (PB1)
STA:6+21.07
OFF:79.11'L
SIGNAL STD. (S1)
STA:6+24.68
OFF:74.58'L
SIGNAL STD. (S2)
STA:6+09.76
OFF:56.83'L
STA:6+10.80
OFF:48.68'L
STA:6+10.55
OFF:48.73'R
SIGNAL STD. (S3)
STA:6+24.71
OFF:77.17'R
SIGNAL STD. (S4)
STA:6+95.57
OFF:76.54'R
STA:6+85.60
OFF:75.63'R
SIGNAL STD. (S5)
STA:7+08.83
OFF:56.95'R
STA:7+07.82
OFF:48.63'R
SIGNAL STD. (S6)
STA:7+01.67
OFF:74.55'L
PULL BOX (PB4)
STA:6+94.69
OFF:77.53'L
STA:7+08.55
OFF:58.94'L
STA:6+91.69
OFF:73.56'L
PULL BOX (PB3)
STA:6+10.13
OFF:66.32'R
STA:6+32.62
OFF:76.10'R
ND
SU-6-986(120)124 21589 150 1
TRAFFIC SIGNAL SYSTEM
TRAFFIC SIGNAL LAYOUT
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 15 30
11
10
12
13
14
15
16
1719
20
2
4
5
6
7
3
1
9
P1
P2
P3
P4
P5
P6
P7
P8
PP8
PP5
PP4
PP3
PP2
PP1
PP6PP7
S. WASHINGTON ST.
S. WASHINGTON ST.
44T
H A
VE
. S
.
LEGEND:
SIGNAL HEAD NUMBER
PEDESTRIAN HEAD NUMBER
PEDESTRIAN PUSH BUTTON
PP4
P4
11
MAST ARM AT 0°
MAST ARM-MOUNTED
SIGNAL HEADS (TYP.)
MAST ARM-MOUNTED
SIGNAL HEADS (TYP.)
SIGNAL HEADS 15 AT 90°
P5 AT 90°
SIGNAL HEADS 16 AT 180°
P6 AT 180°
POLE-MOUNTED SIGNAL HEAD ORIENTATION DETAIL
CONNECT TO NEW
FEED POINT
STA:5+89.45
OFF:124.07'L
INSTALL NEW CONTROLLER
STA:6+04.42
OFF:106.01'L
ND
SU-6-986(120)124 21589 150 2
TRAFFIC SIGNAL SYSTEM
TRAFFIC SIGNAL LAYOUT
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 30 60
5
16
12
13
14
15
10
3
2
9
1
4
6
7
8
18
17
20
19
11
S. WASHINGTON ST. SOUTHBOUND
S. WASHINGTON ST. NORTHBOUND
44T
H A
VE
. S
.
SU-6-986(120)124 21589 150 3
TRAFFIC SIGNAL SYSTEM
SIGNAL STANDARD & HEAD LOCATIONS
S. WASHINGTON ST. & 44TH AVE. S.
23'
35'
1 2 3
5
4
6
44th Ave S
P1 P2
6'
56.5'
5'
12'
21'
28'
33'
44'
54'
58'
SOUTHBOUND SOUTH WASHINGTON STREET (SIGNAL STD 1 & SIGNAL STD 2)
SOUTH WASHINGTON STREET & 44TH AVENUE SOUTH
30
'
MIN
1
9', M
AX
2
1'
STA 6+24.68, 74.58'L
CENTER OF POLE
SIGNAL STD (S1)
PED. PUSH BTN 2
STA 6+32.62,
73.58'L
STA 6+09.76, 56.83'L
CENTER OF POLE
SIGNAL STD (S2)
PED. PUSH BTN 1
STA 6+10.80, 48.68'L
R3-5R
30" X 36"
EMERGENCY VEHICLE
PRE-EMPTION GPS
DETECTOR & LIGHT
RED LIGHT CONFIRMATION
INDICATOR
VIDEO DETECTION CAMERA #1
WITH 5' RISER
CAPPED
DEPARTURE ROADWAY
APPROACH ROADWAY
1'
16.7'8.1'7.2'
13'
THRU
13'
THRU
5.5'
MEDIAN
13'
LEFT
9'
PAINTED MEDIAN
4'
13'
RIGHT
12.3'
THRU
12.3'
THRU
9'
PAINTED MEDIAN
12.5'
LEFT5.5'
MEDIAN
FUTURE 5 SECTION
HEAD
SU-6-986(120)124 21589 150 4
TRAFFIC SIGNAL SYSTEM
SIGNAL STANDARD & HEAD LOCATIONS
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 15 30
24'
36.5'
57.5'
11 12 13
14
15
16
P5 P6
NORTHBOUND SOUTH WASHINGTON STREET (SIGNAL STD 4 & SIGNAL STD 5)
SOUTH WASHINGTON STREET & 44TH AVENUE SOUTH (PROPOSED)
22'
29'
44.5'
54'
59'
6'
30
'
MIN
1
9', M
AX
2
1'
STA 6+95.57, 76.54'R
CENTER OF POLE
SIGNAL STD (S4)
PED. PUSH BTN 6
STA 6+85.60, 75.63'R
STA 7+08.83, 56.95'R
CENTER OF POLE
SIGNAL STD (S5)
PED. PUSH BTN 5
STA 7+07.82, 48.63'R
R10-12
30" X 36"
EMERGENCY VEHICLE
PRE-EMPTION LIGHT
RED LIGHT CONFIRMATION
INDICATOR
VIDEO DETECTION CAMERA # 3
WITH 5' RISER
CAPPED
9'
PAINTED MEDIAN
12.5'
LEFT
5.5'
MEDIAN
14'
THRU
14'
THRU
8' 8.4' 18.7'
0.92'
5.5'
MEDIAN
12.5'
LEFT
9'
PAINTED MEDIAN
12.5'
THRU
12'
THRU
18.3'
DEPARTURE ROADWAY
APPROACH ROADWAY
24'
36.5'
57.5'
11 12 13
14
15
16
P5 P6
NORTHBOUND SOUTH WASHINGTON STREET (SIGNAL STD 4 & SIGNAL STD 5)
SOUTH WASHINGTON STREET & 44TH AVENUE SOUTH (FUTURE WITH RIGHT TURN LANE)
22'
29'
44.5'
54'
59'
6'
30
'
MIN
1
9', M
AX
2
1'
STA 6+95.57, 76.54'R
CENTER OF POLE
SIGNAL STD (S4)
PED. PUSH BTN 6
STA 6+85.60, 75.63'R
STA 7+08.83, 56.95'R
CENTER OF POLE
SIGNAL STD (S5)
PED. PUSH BTN 5
STA 7+07.82, 48.63'R
FUTURE SIGN
EMERGENCY VEHICLE
PRE-EMPTION LIGHT
RED LIGHT CONFIRMATION
INDICATOR
VIDEO DETECTION CAMERA # 3
WITH 5' RISER
CAPPED
9'
PAINTED MEDIAN
12.5'
LEFT
5.5'
MEDIAN
14'
THRU
14'
THRU
8' 8.4' 18.7'
0.92'
5.5'
MEDIAN
12.5'
LEFT
9'
PAINTED MEDIAN
12.5'
THRU
12'
THRU
13'
FUTURE RIGHT
5.3'
DEPARTURE ROADWAY
APPROACH ROADWAY
FUTURE 5
SECTION HEAD
44th Ave S
5'
12'
FUTURE
R3-5R
30" X 36"
44th Ave S
SU-6-986(120)124 21589 150 5
TRAFFIC SIGNAL SYSTEM
SIGNAL STANDARD & HEAD LOCATIONS
S. WASHINGTON ST. & 44TH AVE. S.
27.5'
18
19
20
S Washington St
P7 P8
6'
17.5'
22'
6'
35'
EASTBOUND 44TH AVENUE SOUTH (SIGNAL STD 3)
SOUTH WASHINGTON STREET & 44TH AVENUE SOUTH
PED. PUSH
BTN 7
STA 6+32.62,
76.10'R
PED. PUSH BTN 8
STA 6+10.55, 48.73'R
30
'
MIN
1
9', M
AX
2
1'
EMERGENCY VEHICLE
PRE-EMPTION LIGHT
CAPPED
VIDEO
DETECTION
CAMERA #2
WITH 5'
RISER
STA 6+24.71, 77.17'R
CENTER OF POLE
SIGNAL STD (S3)
RED LIGHT CONFIRMATION
INDICATOR
14.1'7.9'6.5'
20'
THRU RIGHT & LEFT
20'
15'
THRU RIGHT & LEFT
DEPARTURE ROADWAY
APPROACH ROADWAY
SU-6-986(120)124 21589 150 6
TRAFFIC SIGNAL SYSTEM
SIGNAL STANDARD & HEAD LOCATIONS
S. WASHINGTON ST. & 44TH AVE. S.
31'
8
9 10
P3 P4
8'
18'
25.5'
33.5'
6'
WESTBOUND 44TH AVENUE SOUTH (SIGNAL STD 6)
SOUTH WASHINGTON STREET & 44TH AVENUE SOUTH
30
'
MIN
1
9', M
AX
2
1'
Ped. Push Btn 4
Sta 7+09.05, 58.45'L
PED. PUSH
BTN 3
STA 6+91.69,
73.56'L
STA 7+01.67, 74.55'L
CENTER OF POLE
SIGNAL STD (S6)
EMERGENCY VEHICLE
PRE-EMPTION LIGHT
RED LIGHT
CONFIRMATION
INDICATOR
VIDEO
DETECTION
CAMERA #4
WITH 5' RISER
CAPPED
7.4'10'16.4'
15'
THRU RIGHT & LEFT
21'
20'
THRU RIGHT & LEFT
DEPARTURE ROADWAY
APPROACH ROADWAY
S Washington St
SU-6-986(120)124 21589 150 7
TRAFFIC SIGNAL SYSTEM
SIGNAL HEADS & CONDUCTOR SCHEDULE
S. WASHINGTON ST. & 44TH AVE. S.
(12" Lenses)
Heads
1,9,11,19
(12" Lenses)
Heads
2,3,4,5,6,8,10,12,13,
14,15,16,,18, 20
Future Heads
7,17
(12" Lenses)
Heads
P1,P2,P3,P4,
P5,P6,P7,P8
Blank Squares Denote a Red Indication
(A) When one phase is on alone, any nonconflicting
phase may start timing concurrently without
a clearance interval. (See Chart A)
(B) Pedestrian Movements, upon actuation
EMERGENCY VEHICLE PRE-EMPTION PHASING
WestBound SouthBound EastBound NorthBound
Phase
On
Non-Conflicting Phase
Allowed to Time Concurrently
1
2
4
5
6
8
Chart A
(A)
Protected Movement
Permitted Movement
Pedestrian Actuation
5 or 6
5 or 6
7 or 8
1 or 2
1 or 2
3 or 4
Ø8 Ø6 & Ø1 Ø4 Ø2 & Ø5
3
7
7 or 8
3 or 4
PHASE 1 PHASE 2 PHASE 4 PHASE 5 PHASE 6 PHASE 8
16
15
13
3
2
17
1
8
7
6
5
12
11
R
W W
R
W
R
W
R
W
R
W
R
2 3 4 5 6 7 8 3 4 5 6 7 8 1 5 6 7 8 1 6 7 8 1 7 8 1 2 3 4 5 6 712 3 4 52 3 42 3
(A)
(A)
(A)
(A)
10
18
Clear to Ø Clear to Ø Clear to Ø Clear to Ø Clear to Ø Clear to Ø
PHASE 3
R Clear to Ø
PHASE 7
R Clear to Ø
W W
4 5 6 7 8 1 2 8 2 3 4 5 61
20
19
14
9
4
S WASHINGTON & 44TH AVE S
CONTROLLER PHASING
SU-6-986(120)124 21589 150 8
TRAFFIC SIGNAL SYSTEM
SIGNAL CONTROLLER PHASING
S. WASHINGTON ST. & 44TH AVE. S.
SU-6-986(120)124 21589 150 9
TRAFFIC SIGNAL SYSTEM
TRAFFIC SIGNAL SYSTEM QUANTITIES
S. WASHINGTON ST. & 44TH AVE. S.
*Items shown above are for informational purposes only. Contractor shall provide all materials, labor, and equipment necessary for the signal system to be fully operational as shown in the plans
FOFO
UGCUGC
UG
CU
GC
UGC
UGC
U
G
E
G
A
S
ND
SU-6-986(120)124 21589 150 10
TRAFFIC SIGNAL SYSTEM
DETECTOR ZONE LAYOUT
S. WASHINGTON ST. & 44TH AVE. S.
Feet
0 60 120
ZONE
2-3
ZONE
2-2
ZONE
2-4
ZONE
2-5
ZONE
4-2
ZONE
4-3
ZONE
4-5
ZONE
4-4
ZO
NE
1-1
ZO
NE
3-1
ZONE
4-1
ZONE
2-1
44T
H A
VE
. S
.
Phase Diagram
EB
SB
NB
WB
6
1
8
2
5
4
VIDEO DETECTION CAMERA 3
VIDEO DETECTION CAMERA 1
VIDEO DETECTION CAMERA 2
VIDEO DETECTION CAMERA 4
ND
SU-6-986(120)124 21589 150 11
SIGN DESIGN DETAILS
S. WASHINGTON ST. & 44TH AVE. S.
S WashingtonSt
44th Ave
3.0" Radius, 1.0" Border, White on Blue;
[S Washington St] Letter Series D
80% Spacing
Table of letter and objects lefts.
3.0" Radius, 1.0" Border, White on Blue;
[47th Ae S] Letter Series D
80% Spacing
Table of letter and objects lefts.
S
44th Ave S
WashingtonSt
F
O
FO
FO
FO
FOFO
FO FOFO FO
FOFO
F
O
FOFOFOFO
FOFOFO
FOFOFO
FOFO
FO
F
O
FO
FO
FO
FOFO
FO FOFO FO
FOFO
ND
SU-6-986(120)124 21589 160 1
FIBER OPTIC INTRERCONNECT
SOUTH WASHINGTON ST. & 44TH AVE. S.
Feet
0 20 40
8
7
'
9
5
.3
'
55.4'
276.1'
649.7'
228.4'
422.3'119.4' 279.9'
550.7'
1
2
3
.1
'
NEW & EXISTING FIBER
IN NEW CONDUIT FROM
CONTROLLER TO NEW
PULL BOX
EXISTING FIBER IN EXISTING CONDUIT
FROM NEW PULL BOX TO
CONTROLLER @ 40TH AVE. S.
NEW FIBER IN EXISTING
CONDUIT FROM NEW
PULL BOX TO
CONTROLLER @ 47TH
AVE. S.
S. WASHINGTON ST. SOUTHBOUND
44
TH
A
VE
. S
.
42
ND
AV
E. S
.
S. WASHINGTON ST. NORTHBOUND
47
TH
A
VE
. S
.4
7T
H A
VE
. S
.
S. 11TH ST.
S. 11TH ST.
40
TH
A
VE
. S
.
46
TH
A
VE
. S
.
40
TH
A
VE
. S
.
EXISTING
PULLBOX
NEW PULL BOX
EXISTING CONTROLLER