    Accessibility for the Disabled

    - A Design Manual for a Barrier Free Environment -

    PHOSPlatform Handicap en Ontwikkelingssamenwerking

    Platform Disability and Development Cooperation

    Tivolistraat 45 box 31020 Brussels

    BELGIUM

    Tel.+32-2-421 24 [email protected]

    supported by

    mailto:[email protected]:[email protected]
  • 7/29/2019 Design Consideration PWD

    2/59

    Accessibility for the Disabled

    - A Design Manual for a Barrier-Free Environment -

    About this publication

    About PHOS

    Introduction1. Purpose 4

    2. Application 43. Target group 44. Structure of this publication 4

    References 5

    Dimensional Data 5

    Architectural Design Considerations1. Ramps 52. Elevators 93. Platform Lifts 124. Stairs 155. Railings and Handrails 196. Entrances 237. Vestibules 278. Doors 299. Corridors 3510. Restrooms 37

    Appendixes: Implementation Check listsI. Trouble Shooting 49II. Anthropometrics 52

    2

  • 7/29/2019 Design Consideration PWD

    3/59

    About this publication

    This publication is prepared for NGOs and their partners in developing countrieswho want to take the needs of disabled people into account. The presentedguidelines for a barrier-free environment can be used for creating accessiblebuildings for disabled people in the context of development projects. An

    accessible environment is a precondition for disabled people to take part ineducation, training or work or to benefit from services which are offered by

    NGOs and their partners. Barrier-free environments are essential for fullparticipation and equality of disabled people.

    If you want to read more about accessibility for disabled people, please consult the websiteof PHOS, www.phos.be or http://www.un.org/esa/socdev/enable/. This publication is a

    summary of some materials available at the Enable website of the United Nations.

    About PHOS

    PHOS is a Belgium-based NGO whos objective is to enhance the opportunities of peoplewith disabilities from the South to make their voice heard and to improve their livingconditions. Our strategy is facilitating the mainstreaming of disability in the programmes andactivities of NGOs and their partners in developing countries. We support mainstreaming ofdisability in NGOs by research, publications, training and consultation.

    3

  • 7/29/2019 Design Consideration PWD

    4/59

    Introduction

    We are all physically disabled at some time in our lives. A child, a person with a broken leg, aparent with a pram, an elderly person, etc. are all disabled in one way or another. Those whoremain healthy and able-bodied all their lives are few. As far as the built-up environment is

    concerned, it is important that it should be barrier-free and adapted to fulfil the needs of allpeople equally. As a matter of fact, the needs of the disabled coincide with the needs of themajority, and all people are at ease with them. As such, planning for the majority impliesplanning for people with varying abilities and disabilities.

    1. Purpose

    This publication is a design manual on accessibility for the disabled. It is a design guidemade for the purpose of providing architects and designers with the basic information anddata necessary for a barrier-free environment. It is meant to establish standards andrecommendations that will improve your construction projects to meet the needs of all target

    groups. The manual is expected to be a stimulus that will lead, in the long run, to theestablishment of national building and planning legislation covering access for disabledpeople.

    2. Application

    The manual does not cover all the requirements of disabled people in detail. It is astraightforward guide expected to be the first in a series of publications having the sametopic. Most of the recommended measures have been tested and have proven to beeffective. Practical advice from legal, professional and academic institutions as well as

    individuals with disabilities is also of the utmost importance in shaping the final form of anaccessibility code.

    3. Target group

    The target group is composed of five major categories:

    (a) Wheelchair users(b) People with limited walking abilities(c) The sightless

    (d) The partially sighted(e) The hearing impaired

    Other categories may benefit to some extent from the proposed measures.

    4. Structure of this publication

    Each chapter is composed of four parts:

    1) Problem identification

    This part defines problems encountered by the disabled in the built-up environment owing tothe absence or improper application of a certain measure or provision.

    4

  • 7/29/2019 Design Consideration PWD

    5/59

    2) Planning principle

    This part identifies the target group, the general goal and the need for a certain measure.

    3) Design considerations

    This part deals with the technical and architectural aspects of implementing certain measureswith regard to general and particular application characteristics, criteria, minimumdimensions and measurements, materials, etc.

    4) Existing constructions

    This part identifies the problems encountered in existing constructions which hinder theimplementation of a certain measure. Accordingly, alternative solutions and modifications aresuggested.

    References

    The information provided is based on the accessibility codes and relevant knowledgeavailable in various countries. A comparative study of the available sources was conductedregarding each measure. The information was then synthesized and organized according tothe needs of the target group.

    Dimensional Data

    Dimensional data are given in metric units. The graphic illustrations show only the minimumallowable dimensions. Where appropriate, the maximum or approximate dimension or anallowable range is given. For your information: 1 cm = 0,394 inch and 1 inch = 2,54 cm.

    5

  • 7/29/2019 Design Consideration PWD

    6/59

    ARCHITECTURAL DESIGN CONSIDERATIONS

    1. RAMPS

    1. PROBLEM IDENTIFICATION

    Inaccessible building entrances due todifference between indoor and outdoorlevels.

    Inaccessible routes due to differences inlevel.

    Lack of or improper design of ramps.

    Very steep and/or long ramps with noresting landings.

    2. PLANNING PRINCIPLE

    To provide ramps wherever stairsobstruct the free passage ofpedestrians, mainly wheelchair usersand people with mobility problems.

    3. DESIGN CONSIDERATIONS

    3.1 General

    An exterior location is preferred forramps. Indoor ramps are notrecommended because they take up agreat deal of space.

    Ideally, the entrance to a ramp shouldbe immediately adjacent to the stairs.

    3.2 Ramp configuration (1)

    Ramps can have one of the followingconfigurations:

    (a) Straight run (fig. 1);

    (b) 90 turn (fig. 2);

    (c) Switch back or 180turn (fig. 3).

    Fig 1.

    Fig 2.

    Fig. 3.

    6

  • 7/29/2019 Design Consideration PWD

    7/59

    7

    3.3 Width

    Width varies according to use,configuration and slope.

    The minimum width should be 0.90m.

    3.4 Slope

    The maximum recommended slope oframps is 1:20. Steeper slopes may beallowed in special cases depending onthe length to be covered (fig. 4).

    Maximumslope

    Maximumlength

    Maximumrise

    1:20 i.e.,9%

    - -

    1:16 i.e.,6%

    8 m 0.50 m

    1:14 i.e.,7%

    5 m 0.35 m

    1:12 i.e.,8%

    2 m 0.15 m

    1:10 i.e.,

    10%

    1.25 m 0.12 m

    1:08 i.e.,12%

    0.5 m 0.06 m

    3.4 Landings

    Ramps should be provided withlandings for resting, maneuvering andavoiding excessive speed.

    Landings should be provided every10.00 m, at every change of directionand at the top and bottom of everyramp.

    The landing should have a minimumlength of 1.20 m and a minimum widthequal to that of the ramp

    3.5 Handrail

    A protective handrail at least 0.40 m

    Fig. 4.

  • 7/29/2019 Design Consideration PWD

    8/59

    of ramps.

    For ramps more than 3.00 m wide, anintermediate handrail could be installed(fig. 5).

    The distance between handrails whenboth sides are used for gripping shouldbe between 0.90 m and 1.40 m (fig. 5).

    3.6 Surface

    The ramp surface should be hard andnon-slip.

    Carpets should be avoided.

    3.7 Tactile marking

    A coloured textural indication at thetop and bottom of the ramp should beplaced to alert sightless people as to thelocation of the ramp.

    The marking strip width should not beless than 0.60 m.

    3.8 Drainage n Adequate drainage

    should be provided to avoidaccumulation of water.

    3.9 Obstacles

    The same clearance considerationsthat apply to pathways apply to ramps(see Obstructions).

    3.10 Mechanical Ramps

    Mechanical ramps can be used inlarge public buildings but are notrecommended for use by persons withphysical impairments.

    If the ramp is to be used by awheelchair-confined person, the slopeshould not exceed 1:12.

    The maximum width should be 1.00

    m to avoid slipping.

    8

  • 7/29/2019 Design Consideration PWD

    9/59

    4. EXISTING CONSTRUCTIONS

    If the topography or structure of theexisting building is restrictive, minorvariations of gradient are allowed as afunction of the ramp length:

    Maximumslope

    Maximumlength

    Maximumrise

    1:20 i.e.,9%

    - -

    1:16 i.e.,6%

    8 m 0.50 m

    1:14 i.e.,7%

    5 m 0.35 m

    1:12 i.e.,8% 2 m 0.15 m

    1:10 i.e.,10%

    1.25 m 0.12 m

    1:08 i.e.,12%

    0.5 m 0.06 m

    A non-slip surface finish should beadded to slippery ramps.

    Notes:

    (1) Circular or curved ramps are notrecommended

    9

  • 7/29/2019 Design Consideration PWD

    10/59

    2. ELEVATORS

    1. PROBLEM IDENTIFICATION

    Inadequate space inside theelevator cab.

    High position of switches, buttonsand control panel.

    Narrow entry doors.

    Insufficient opening time interval.

    2. PLANNING PRINCIPLE

    To provide well-dimensionedelevators, that disabled peoplecan use conveniently.

    3. DESIGN CONSIDERATIONS

    3.1 General

    The accessible elevator shouldserve all floors normally reachedby the public.

    Key-operated elevators shouldbe used only in private facilitiesor when an elevator operator ispresent.

    Wide elevator cabs arepreferable to long ones.

    3.2 Elevator cab

    The minimum internal elevatordimensions, allowing for onewheelchair passenger alone, are1.00 m x 1.30 m (fig. 1).

    The door opening should notbe less than 0.80 m.

    The inside of the elevatorshould have a handrail on threesides mounted 0.80 to 0.85 m

    from the floor (fig. 2).

    Fig. 1

    Fig. 2

    Fig. 3

    10

  • 7/29/2019 Design Consideration PWD

    11/59

    The maximum tolerance forstop precision should be 20 mm.

    3.3 Control panel

    The control panel can bemounted at alternative locationsbut it is recommended to respecta distance of 0,50 m from thecorner with regard to theaccessibility for wheelchair users.

    For ease of reach, the controlpanel should be mounted 0.90 mto 1.20 m from the floor (fig. 2).

    Control buttons should be in an

    accessible location andilluminated. Their diametershould be no smaller than 20mm.

    The numerals on the floorselector buttons should beembossed so as to be easilyidentifiable by touch.

    3.4 Call buttons

    For ease of reach, call buttonsshould be mounted 0.90 m to1.20 m from the floor (fig. 4). 3.5Floor identifiers

    Tactile numerals should beplaced on both sides of the doorjambs at an approximate heightof 1.50 m to help a lone sightlesspassenger to identify the floorreached (fig. 4). 3.6 Hall signal

    The elevator hall signal shouldbe placed at an approximateheight of 1.80 m (fig. 4).

    3.7 Door re-opening activators

    The door opening intervalshould be no less than fiveseconds. Re-opening activatorsshould be provided.

    Fig. 4

    11

  • 7/29/2019 Design Consideration PWD

    12/59

    3.8 Audiovisual signals

    The elevator should signalarrival at each floor by means of

    a bell and a light to alert sightlessand hearing-impaired passengerssimultaneously.

    3.9 Floor surface

    The floor of the elevator andthe area in front of the elevatoron each floor should have a nonskid resilient surface or a low-pilefixed carpet.

    3.10 Colour

    The colour of the elevator doorshould contrast with thesurrounding surface so as to beeasily distinguishable by personswith visual impairments.

    4. EXISTING CONSTRUCTIONS

    The minimum acceptable sizeof an existing elevator cab,allowing for a single wheelchairpassenger, is 0.95 m x 1.25 m.Smaller cabs should be replaced.

    The minimum acceptable widthof an existing elevator dooropening is 0.75 m.

    Call buttons and control panels

    mounted higher than therecommended height may be leftin place if they are within 1.40 mof the floor, this being themaximum reach of a wheelchairuser.

    Controls mounted higher than1.40 m should be replaced.

    Where there are two identicalcontrol panels, only one need be

    replaced.

    12

  • 7/29/2019 Design Consideration PWD

    13/59

    3. PLATFORM LIFTS (1)

    1. PROBLEM IDENTIFICATION

    Changes in level between indoorand outdoor areas.

    Changes in level inside abuilding.

    Insufficient space for ramps.

    2. PLANNING PRINCIPLE

    To allow people with mobilityproblems to have free vertical

    access between different levels.

    3. DESIGN CONSIDERATIONS

    3.1 General

    Platform lifts are specialpassenger-elevating devices forthe disabled.

    Platform lifts can have either a

    vertical or an inclined movement.

    3.2 Vertical movement platformlifts

    For maximum level changes of2.50 m, vertical movementplatform lifts may be installedadjacent to the stairs (fig. 1).

    For level changes of more than

    1.20 m, the lift should be placedin a closed structure with doors atthe different accessible levels(fig. 2).

    Vertical platform lifts can havea variety of opening for entry andexit (fig. 3).

    Fig. 1

    Fig. 2

    13

  • 7/29/2019 Design Consideration PWD

    14/59

    3.3 Inclined movement platformlifts

    Inclined movement platformlifts consist of three elements: arailing, an electric generator anda moving platform or seat.

    The operating system of the liftcan be either lateral (fig. 4) orsuspended (fig. 5).

    Inclined movement platformlifts can be installed along the

    stair wall, as long as they do notobstruct the required width of theexit. The seat or platform can befolded when not in use.

    The minimum width of thestairs should be 0.90 m to allowthe installation of a lift (fig. 6).

    Platform lifts can be installedon all types of stairs including

    switch-back stairs i.e. those witha rotation angle of 180 (fig. 7)and spiral staircases (fig. 5).

    3.4 Lift size

    The minimum width of the liftplatform should be 0.90 m andthe minimum length should be1.20 m (fig. 3).

    4. EXISTING CONSTRUCTIONS

    Platform lifts can provideaccess to existing buildingswhere it would be difficult orunfeasible to install a ramp or anelevator.

    Inclined movement platformlifts are usually used to connect

    one or more floors or to

    Fig. 3

    Fig. 4

    Fig. 5

    14

  • 7/29/2019 Design Consideration PWD

    15/59

    buildings. In buildings that are orwould be frequently used bypersons with mobility problems,such devices should not beutilized.

    Notes:

    (1) Platform lifts are also knownas stairway lifts or wheelchairlifts.

    Fig. 6 Fig. 7

    15

  • 7/29/2019 Design Consideration PWD

    16/59

    4. STAIRS

    1. PROBLEM IDENTIFICATION

    Steep staircases.

    Poorly designed steps that hinderfoot movement.

    2. PLANNING PRINCIPLE

    To provide safe and well-dimensioned staircases for thecomfort of all people, especiallythose with mobility problems.

    3. DESIGN CONSIDERATIONS

    3.1 General

    Differences in level should beilluminated or minimized as muchas possible for the comfort ofdisabled people.

    A complementary rampedroute, elevator or lift should be

    provided where there are steps inan otherwise accessible path.

    All steps should be uniform.

    Circular stairs and steppedlandings should be avoided (fig.1).

    Open risers are notrecommended.

    3.2 Width

    The minimum width of astairway should be 0.90 m forone-way traffic and 1.50 m fortwo-way traffic.

    For indoor stairs, the risershould be between 0.12 m and0.18 m, and the tread between

    0.28 m and 0.35 m.

    Fig. 1

    Fig. 2

    Fig. 3

    16

  • 7/29/2019 Design Consideration PWD

    17/59

    For outdoor stairs, themaximum riser should be 0.15 mand the minimum tread should be0.30 m.

    3.3 Landing (fig. 2) (fig. 3)

    An intermediate landing shouldbe provided when the stairs covera difference in level of more than2.50 m.

    The length of the landingshould be at least 1.20 mextending along the full width of

    the stairs.

    3.4 Nosing (fig. 4)

    Sharp edges and overhangingnosing should not be used fortreads.

    Nosing should be flush orrounded and should not beprojected more than 40 mm.

    3.5 Handrails

    Handrails must be installed onboth sides of the stairs andaround the landing for gripping(fig. 3).

    For stairs more than 3.00 mwide, one or more intermediatehandrails could be provided (fig.

    5).

    The distance between thehandrails when both sides areused for gripping should bebetween 0.90 m and 1.40 m (fig.5).

    Handrails must extend adistance between 0.30 m and0.45 m at the top and bottom ofthe stairs (see Railings andHandrails) (fig. 3).

    Fig. 4: Recommended nosing types

    Fig. 5

    Fig. 6

    17

  • 7/29/2019 Design Consideration PWD

    18/59

    3.6 Tactile marking (fig. 2) (fig. 3)

    A textural marking strip shouldbe placed at the top and bottomof the stairs and at intermediatelandings to alert sightless people

    as to the location of the stairs.

    The tactile marking strip shouldbe at least 0.60 m wide andshould extend over the full widthof the stairs.

    To guide users with poorvision, the colour of the stripshould contrast with thesurrounding surface. 3.7 Surface

    Landings, treads and nosingshould be slip-resistant and freeof projections.

    Exterior stairs should bepitched forward at 10 mm permetre to drain surface water.

    Slip-resistant stair nosingshould be used to fix carpets on

    stairs.

    3.8 Emergency stairs

    Emergency stairs should beidentified by tactile markings.

    3.9 Mechanical stairs (escalators)

    Mechanical stairs can beprovided with an adaptable tread

    at least 1.20 m long, if they are tobe used by persons confined towheelchairs (fig. 6).

    The edges of escalators shouldbe painted in a contrasting colourfor the benefit of poor- sightedusers.

    Fig. 7

    18

  • 7/29/2019 Design Consideration PWD

    19/59

    4. EXISTING CONSTRUCTIONS

    When the configuration of thenosing cannot be modified, slip-resistant strip scould be appliedto the nosing as an alternative

    solution (fig. 7).

    Slip-resistant strips should be40 mm wide and should notextent more than 1 mm above thetread surface.

    To guide people with sightproblems, the colour of the stripsshould contrast with that of thestairs.

    19

  • 7/29/2019 Design Consideration PWD

    20/59

    5. RAILINGS AND HANDRAILS

    1. PROBLEMIDENTIFICATION

    Unsafe railings.

    Hard to grip handrails.

    No railings or handrails.

    2. PLANNING PRINCIPLE

    To install adequate railing,wherever needed for the comfortand safety of all people,especially those with mobilityproblems.

    3. DESIGN CONSIDERATIONS

    3.1 General

    Safety guards or railingsshould be installed aroundhazardous areas, stairs, ramps,accessible roofs, mezzanines,

    galleries, balconies and raisedplatforms more than 0.40 m high.

    On stairways, windowspositioned less than 1.00 m fromthe landing should have railings.

    Handrails should be installed toassist disabled persons inbathrooms and toilets (see RestRooms).

    Spacing between the verticaland horizontal bars of railingsshould be narrow for the safety ofchildren.

    Handrails should not obstructthe path of travel.

    Fig 1.

    Fig 2.

    Fig 3.

    Fig 4

    20

  • 7/29/2019 Design Consideration PWD

    21/59

    21

    3.2 Height (fig. 1) (1)

    To facilitate use by ambulantdisabled and elderly people,handrails should be mountedbetween 0.85 m and 0.95 m

    above the finished floor level.

    For the benefit of wheelchairusers, a second handrail can bemounted between 0.70 m and0.75 m from the floor.

    To facilitate use by childrenand short people, a third handrailcan be mounted at a height of0.60 m.

    To guide sightless peopleusing a long cane, a rail shouldbe mounted at a height between0.10 m and 0.15 m (fig. 1); or alow curb should be installed at aheight between 50 mm and 75mm (fig. 2). Low curbs also act aswheelstops.

    3.3 Mounting

    Railings should be securelyattached to the wall or to asupporting structure so as towithstand heavy loads.

    Railings should not endabruptly but extend to the floor orblend into the wall so as not tocreate a hazard for sightlesspeople.

    3.4 Form (fig. 3)

    Handrails should allow a firmand easy grip.

    Circular cross-sections with adiameter of 40 mm arepreferable.

    Sharp edges should beavoided.

    Fig 5.

    Fig 6.

  • 7/29/2019 Design Consideration PWD

    22/59

    3.5 Handrails for ramps andstairs

    Handrails should continueuninterrupted (except fordoorways) on both sides and

    around the landing.

    Handrails should extendhorizontally for a distancebetween 0.30 m and 0.45 m atthe top and bottom of stairs andramps, except in places whereextensions could obstruct thepedestrian flow (fig.4).

    For stairs or ramps more than

    3.00 m wide, a continuousintermediate handrail could beprovided (see Ramps; Stairs).

    3.6 Wall-mounted handrails

    The space between thehandrail and the wall should bebetween 40 mm and 50 mm forsmooth walls and 60 mm forrough textured walls (fig. 5).

    Where handrails are fullyrecessed into walls, a space of atleast 0.15 m should be allowedbetween the top of the rail andthe top of the recess (fig. 6).

    3.7 Tactile marking

    For emergency exit stairs orramps, a contrasting tactile stripat least 0.90 m long should beapplied to the top and bottomedges of the handrail to alert thepartially sighted.

    3.8 Colour

    A contrasting colour isrecommended for handrails toalert people with sight problems.

    22

  • 7/29/2019 Design Consideration PWD

    23/59

    4. EXISTING CONSTRUCTIONS

    If existing railings andhandrails do not comply with theabove requirements, they shouldbe modified or replaced.

    Notes:

    (1) Measurements are taken fromthe front of the tread.

    23

  • 7/29/2019 Design Consideration PWD

    24/59

    6. ENTRANCES

    1. PROBLEM IDENTIFICATION

    No distinct accessible entrance.

    Inadequate space in front of theentrance.

    2. PLANNING PRINCIPLE

    To provide accessible and easy-to-find building entrances.

    3. DESIGN CONSIDERATIONS

    3.1 General

    For new accessibleconstructions, all main publicentrances should be accessibleto an ambulant disabled person.

    At least one entrance perfacility should be accessible to awheelchair user. In newbuildings, the accessible

    entrance(s) should be the mainentrance(s) intended for use bythe general public.

    Each accessible entranceshould be connected byaccessible pathways toaccessible indoor or outdoorparking areas, local publictransit stops and drop-off areas(fig. 1).

    In multi-storey buildings, theaccessible entrance shouldpermit access to a convenientlylocated accessible elevator orlift.

    Fig. 1

    Fig. 2

    24

  • 7/29/2019 Design Consideration PWD

    25/59

    25

    3.2 Signs

    Accessible entrances shouldbe clearly identified using theinternational symbol ofaccessibility including alternate

    locations of accessibleentrances (fig. 2).

    No signs are needed if thewhole building is accessible.

    3.3 Entrance landing

    Where the entrance dooropens outward, the minimumlanding dimensions should

    comply with figure 3.

    Where the entrance dooropens inward, the minimumlanding dimensions shouldcomply with figure 4.

    The surface of the landingshould have a slope of 2% fordrainage.

    The finish material should benon-slippery.

    Jute door mats should beavoided. When used however,the upper surface of the matshould be level with the floorfinish (fig. 5).

    Sheltered landings arepreferable.

    3.4 Threshold

    Thresholds should beremoved wherever possible (seeDoors).

    3.5 Colour

    The colour of the entrance

    door should contrast with thesurrounding surface so as to be

    Fig. 3

    Fig. 4

    Fig. 5

  • 7/29/2019 Design Consideration PWD

    26/59

    sight problems.

    3.6 Entrance vestibules (seeVestibules)

    3.7 Entrance doors (see Doors)

    4. EXISTINGCONSTRUCTIONS

    Public buildings should haveat least one accessibleentrance. Wherever possible,this should be the main entranceintended for use by the general

    public(1)

    .

    If for architectural or technicalreasons the main entrancecannot be made accessible, analternative accessible entranceshould be provided. The locationof the alternative entranceshould be clearly indicated bysigns.

    To allow for an accessibleentrance, one of the followingsolutions can be adapted:

    (a) Ramps, bridges ormechanical lifts be used; (2)

    (b) The entrance level might bemodified earthfill, or by changingthe grade or the landscaping ofthe surrounding site;

    (c) A window or another door atground might be converted intoan accessible entrance.

    26

  • 7/29/2019 Design Consideration PWD

    27/59

    Notes:

    (1) For existing constructions, aservice entrance can be usedtemporarily as an accessible

    entrance, but it should not bethe only accessible entrance.

    (2) Mechanical lifts arerecommended for buildingswhere modifications areimpossible or unacceptable.

    27

  • 7/29/2019 Design Consideration PWD

    28/59

    7. VESTIBULES

    1. PROBLEM IDENTIFICATION

    Narrow doorways and vestibules.

    2. PLANNING PRINCIPLE

    To provide sufficient space tomanoeuvre a wheelchair betweentwo sets of doors.

    3. DESIGN CONSIDERATIONS

    3.1 General

    Vestibule entrance doors canbe either the sliding type or theswinging type.

    For swinging doors, the doormechanism should allow themaximum opening swing.

    3.2 Layout

    The layout of two swingingdoors in a series can be one ofthe following:

    (a) Outward-swinging (fig. 1);

    (b) Double-swinging (fig. 2);

    (c) Swinging in the samedirection (1) (fig. 3);

    (d) Inward-swinging (fig. 4).

    4. EXISTING CONSTRUCTIONS

    For narrow vestibules either ofthe following solutions can beemployed:

    (a) Replace swinging doors withsliding doors;

    Fig. 1

    Fig. 2

    Fig. 3

    28

  • 7/29/2019 Design Consideration PWD

    29/59

    (b) Change the direction of thedoor swing so that both doorscan be made to swing outwards,if possible (fig. 5).

    (c) Install double-swinging doors

    for small exit vestibules with aminimum width of 1.20 m.

    (d) Remove the inside or seconddoor.

    (e) Enlarge the existing vestibuleif possible (2)(fig. 6).

    Notes:

    (1) Doors swinging in the samedirection can be aligned, offset onopposite walls or offset onadjacent walls.

    (2) This is recommended forvestibules that also serve asemergency exits because othersolutions, such as changing thedirection of the door swing, might

    not solve the problem.

    Fig. 4

    Fig. 5

    Fig. 6

    29

  • 7/29/2019 Design Consideration PWD

    30/59

  • 7/29/2019 Design Consideration PWD

    31/59

    31

    - Automatic doors should havean adequate opening interval. -Guard-rails can be installednear double-swinging doors to

    indicate a door-opening areaand to prevent people frombeing hit by the door.

    (b) Revolving doors: -Revolving doors are notsuitable for the use of disabledpeople or people with prams.

    - Wherever there are revolvingdoors, an adjacent accessibleswinging or sliding door shouldbe provided (fig. 3).

    - Auxiliary gates should beprovided next turnstiles (fig. 3).

    (c) Pivoted doors: - Pivoteddoors should swing away fromthe direction of travel whereverpossible.

    - Pivoted doors in series are

    considered as vestibules (seeVestibules).

    (d) Sliding and folding doors: -Manual sliding and foldingdoors are recommended fornarrow spaces not heavilyused by the public (fig. 4).

    3.3 Door opening

    For exterior doors, theminimum opening is 0.90 mwhen the door is open.

    For interior doors, theminimum opening is 0.80 mwhen the door is open.

    The minimum door openingcan be 0.75 m if the access isstraight or if the door can stayopen by itself (fig. 5).

    Fig. 4

    Fig. 5

    Fig. 6

    Fig. 7

  • 7/29/2019 Design Consideration PWD

    32/59

    rest rooms should be 0.75 m.

    For doors installed in anopening more than 0.60 m indepth, the clear door openingshould be at least 0.90 m (fig.

    6).

    For double-leaf doors, atleast one leaf should have aminimum clear width of 0.80 m(fig. 7).

    3.4 Manual door hardware

    Operational devices ondoors, such as handles, pulls,

    latches and locks, should beeasy to grasp with one hand(fig. 8).

    (a) Handles: - Lever-typehandles, push plates or pullhandles are recommended forswinging doors because theyare easy to open. (1)

    - Round knobs are notrecommended.

    - Door handles should belocated at a comfortable heightbetween 0.90 m and 1.00 mfrom the floor surface.

    (b) Locks: Locks on entrancedoors should be mounted at acomfortable height between0.90 m and 1.00 m from thefloor.

    (c) Extra pull handle: Tofacilitate closing, a door fittedwith spring closers should beequipped with an extra pullhandle approximately 0.30 m inlength, preferably placed at aslant. The handle can be bestlocated at 0.50 m from thehinged side of the door andmounted between 0.90 m and1.20 m from the floor.

    Fig. 8

    32

  • 7/29/2019 Design Consideration PWD

    33/59

    3.5 Automatic doors hardware

    Automatic doors can beactivated by:

    (a) Push buttons located at a

    comfortable height between0.90 m and 1.20 m; (b)Activating mats, which can alsoserve as a location cue (fig. 2);

    (c) Card-insert switch;

    (d) Remote control.

    3.6 Threshold (fig. 8)

    Thresholds should beomitted wherever possible.Weather-stripping at the doorbottom is preferred tothresholds.

    The threshold should not bemore than 20 mm higher thanthe finished floor level.

    Thresholds higher than 6

    mm should be levelled or havesloped edges to facilitate thepassage of a wheelchair.

    3.7 Exit doors landing

    The exit landing should notbe lower than the finished floorlevel by more than 20 mm.

    3.8 Glazing and glazed doors

    Outward swinging doors anddoors in public corridors shouldhave low windows to enableusers to see oncoming traffic.The bottom edge of thewindow should not be higherthan 1.00 m from the finishedfloor level (fig. 8).

    33

  • 7/29/2019 Design Consideration PWD

    34/59

  • 7/29/2019 Design Consideration PWD

    35/59

    Door openings narrowerthan 0.75 m should bewidened. A swing-clear hingeddoor may be used to slightlyenlarge an opening.

    Notes:

    (1) Lever type handles can beactivated by hand, elbow orother means.

    35

  • 7/29/2019 Design Consideration PWD

    36/59

    9. CORRIDORS

    1. PROBLEM IDENTIFICATION

    Long and narrow corridorscreating orientation difficulties.

    2. PLANNING PRINCIPLE

    To provide well-dimensionedcorridors to facilitate the passageand manoeuvring of a wheelchair.

    3. DESIGN CONSIDERATIONS

    3.1 General

    Wide corridors are useful forwheelchair users, serviceequipment, high traffic areas, etc.

    3.2 Width

    The unobstructed width of alow-traffic corridor should not beless than 0.90 m. This also allowsmanoeuvrability in 90 turns (fig.

    1).

    The unobstructed width of apublic corridor should not be lessthan 1.50 m (1). Therecommended width is 1.80 m(fig. 2).

    To allow manoeuvrability in 180turns, the minimum circulationspace should be as shown in

    figure 3.

    The corridor width should allowmanoeuvrability through the doorslocated along its length (fig. 2)(fig. 4).

    Fig. 1

    Fig. 2

    Fig. 3

    36

  • 7/29/2019 Design Consideration PWD

    37/59

    3.3 Obstructions

    Obstacles protruding into thecorridor, such as drinkingfountains or public telephones,should be placed outside the

    circulation path, in alcoves or cul-de-sacs (fig. 5).

    Overhanging signs andobstacles should be mounted atleast 2.00 m high (fig. 6).

    3.4 Surface

    Changes in surface level ofmore than 13 mm should be

    ramped.

    Floor surfaces should be non-slip and even. Carpets should besecurely fastened.

    4. EXISTING CONSTRUCTIONS

    Narrow corridors should bewidened along their full length iffeasible; otherwise, passing areas

    should be located at appropriateintervals along the corridor length.

    The minimum width of thepassing area should be 1.50 mand the minimum length shouldbe 2.40 m.

    In highly restricted spaces, theheight of an obstacle or sign canbe dropped to 1.95 m.

    Notes:

    (1) 1.50 m is the minimum widthfor two wheelchairs to pass eachother or for one wheelchair tomake a full turn.

    Fig. 4

    Fig. 5

    Fig. 6

    37

  • 7/29/2019 Design Consideration PWD

    38/59

    10. REST ROOMS

    1. PROBLEMIDENTIFICATION

    Insufficient space inside arest room.

    Poor design and positioningof fixtures and fittings.

    Taps that are difficult togrip.

    2. PLANNING PRINCIPLE

    To provide sufficientaccessible space insiderest rooms, with all fixturesand fittings being withineasy reach.

    3. DESIGNCONSIDERATIONS

    3.1 General

    Turning circles of 1.50 mdiameter are recommendedinside the rest room toallow for full-turnmanoeuvring of awheelchair.

    The ease of transferringfrom a wheelchair to a toiletseat or bidet depends onthe approach. In generalthere are four differentapproaches:

    (a) The parallel approach,which is the easiest (fig. 1);

    (b) The diagonal approach,which is difficult (fig. 2);

    (c) The perpendicularapproach, which is alsodifficult (fig. 3);

    Fig. 1

    Fig. 2

    Fig. 3

    38

  • 7/29/2019 Design Consideration PWD

    39/59

    (d) The frontal approachwhich is the most difficultand needs particular care(fig. 4).

    3.2 Public rest rooms

    In any public rest room,at least one compartmentfor each sex should beaccessible to an ambulantdisabled person.

    In any public rest room atleast one unisexcompartment should beaccessible to a wheelchair

    user.

    Accessible rest roomsshould be marked with theinternational symbol ofaccessibility. No indicationis needed if all rest roomsare accessible.

    Pivoted doors shouldopen outward unlesssufficient space is providedwithin the toilet stall.

    3.3 Special public restrooms

    Installation of a separateunisex unit is alwaysdesirable in publicbuildings, even when allrest rooms are accessible,so as to allow a disabled

    person to be assisted by anattendant of the oppositesex.

    Special rest roomsshould be marked with theinternational symbol ofaccessibility but should notbe the only accessible restrooms.

    Fig. 4

    Fig. 5

    39

  • 7/29/2019 Design Consideration PWD

    40/59

    A water-closet and alavatory should be providedwithin special rest rooms.

    The size and layout ofspecial rest rooms should

    comply with the minimumrequirements (fig. 5).

    3.4 Residential rest rooms

    Residential rest roomsinclude those in privateresidences, health facilities,dormitories and otherresidential institutionalsettings.

    Residential bathroomsare usually equipped with atoilet, a bidet, a wash-basinand a bath-tub or shower.

    In multiple-rest-roomarrangements (such asdormitories):

    (a) Only one wash-basin

    per rest room needs to beaccessible; (b) At least oneshower stall and one toiletstall should be designed fora wheelchair user.

    To save space in privateoccupancies:

    (a) The tiled floor areaadjacent to the tub can beused as a shower space;(b) The wash-basin seatmight be used as a seatduring the use of the wash-basin or the hand shower.

    The size and layout ofresidential rest roomsshould comply with theminimum requirements(fig. 6).

    Fig 6.

    40

  • 7/29/2019 Design Consideration PWD

    41/59

    3.5 Rest room fixtures

    1) Water closets:

    The size and layout ofwater-closets and toilet

    stalls should comply withthe minimum requirement(fig. 7) (fig. 8).

    The height of the toiletseat should be between0.45 m and 0.50 m from thefinished floor level. (1)

    The distance betweenthe centre line of the toilet

    seat and the adjacent wall,if provided with a grip bar,should be between 0.45 mand 0.50 m.

    Grab bars should bemounted on the wall behindthe water closet, if it is ofthe tank-less type, and onthe side wall closest to thewater closet, or mounted onthe floor at the edges of theseat.

    Grab bars should bemounted at a heightbetween 0.85 m and 0.95m from the floor.As analternative, the grab barcould be placed at a slant.

    Flushing arrangementsand toilet paper should be

    placed within reach at aheight between 0.50 m and1.20 m. It is alsorecommended to respect adistance of 50 cm from thecorner.

    Accessible hand-operated flushing controls,located on the open side ofthe water-closet, are

    recommended.

    Fig. 7

    41

  • 7/29/2019 Design Consideration PWD

    42/59

    closets are recommended.

    2) Lavatories:

    The dimensions oflavatories should comply

    with the minimumrequirements (fig. 9).

    The height of a washbasin should be between0.80 m and 0.85 m above

    the finished floor level. A

    70 cm free space under the

    wash basis should be

    respected.

    The distance betweenthe centre line of the wash-basin and the adjacent sidewall should at least be 0.45m.

    The wash-basin may bedrawn forward from the walla distance between 0.15 mand 0.20 m.

    No shelves must belocated above the wash-basin.

    3) Bath-tubs:

    In general bath-tubs aredifficult to use by thoseconfined to a wheelchair

    without the help of anattendant.

    The dimensions of bath-tubs should comply with theminimum requirements (fig.10).

    The minimumdimensions of the bath-tubshould be 1.60 m x 0.70 m.

    The height of the tub

    Fig. 8

    42

  • 7/29/2019 Design Consideration PWD

    43/59

    and 0.50 m from finishedfloor level.

    An in-tub seat or a seatat the same height of thetub should be provided atthe head side of the tub. (1)

    In some cases, itt might beuseful to provide a smallwall at the open side of thebath tube, allowing peopleto sit on this before entering(more easily) the bath tube.

    A grab bar should bemounted on the wallbetween 0.85 m and 0.95m from the finished floor

    level. (2)

    Tubs with a toe recessare recommended.

    4) Showers:

    The dimensions ofshowers should complywith the minimumrequirements (fig. 11) (fig.12).

    The shower should havea seat convenientlypositioned for the showerhead at a height of 0.45 mand 0.50 m. (1)

    The shower seat shouldbe of the hinged pull-downor removable type, notspring-loaded.

    A grab bar should beplaced on the wall oppositethe seat and around theback wall, mounted at aheight between 0.85 m and0.95 m.

    Slip resistant floors arethe best solution; however,rubber mats could provide

    a valid alternative. In thiscase, drain openings

    Fig. 9

    43

  • 7/29/2019 Design Consideration PWD

    44/59

    corner of the stall.

    The floor of the showerstall should not be morethan 20 mm below the levelof the surrounding floor

    area.

    The shower stall shouldhave a levelled thresholdnot exceeding 13 mmabove the finished floor.

    5) Bidets:

    The dimensions of bidetsshould comply with theminimum requirements.

    The upper edge of thebidet should be between0.45 m and 0.50 m from thefinished floor level. (1)

    The distance betweenthe centre line of the bidet

    and the adjacent wallshould be at least 0.45 m.

    Wall mounted bidets arerecommended.

    6) Urinals: (fig. 13)

    At least one accessibleurinal should be provided inpublic rest rooms.

    Urinals should have aclear space on both sides.

    A full-length urinal is themost accessible.

    Urinals with a protrudinglip should be mounted at aheight of 0.45 m from thefinished floor level.

    Fig. 10

    Fig. 11

    Fig. 12

    44

  • 7/29/2019 Design Consideration PWD

    45/59

    3.6 Rest room door

    The clear door openingshould be at least 0.75 mwith the door in the openposition.

    Doors should be lockablefrom inside and releasablefrom outside underemergency situations.

    Regardless of the doortype, a handle should beplaced on the door from the

    inside to facilitate closing.Another handle should beprovided on the outside(see Doors).

    3.7 Accessories

    All accessories, such assoap, towel and toilet paperdispensers, should beplaced at a height between0.50 m and 1.20 m from thefinished floor level and0,50 m from the corner.

    3.8 Grab bars

    Grab bars should beinstalled in water-closets,bath-tubs and showers toassist disabled persons touse the facilities safely andeasily. (2)

    Grab bars should have adiameter of 30 mm to 40mm.

    Wall-mounted grab barsshould extent between 35mm and 45 mm from thewall.

    Grab bars should be

    firmly fixed with stand loadsand should have non-slip

    Fig. 13

    45

  • 7/29/2019 Design Consideration PWD

    46/59

    usually prevent slipping.

    3.9 Mirrors

    Mirrors should besuitable for use by both

    standing and seatedpersons. Low mirrors ordownward tilted mirrors canbe used.

    The bottom edge ofmirrors should be located ata maximum height of 1.00m from the finished floorlevel (fig. 9).

    3.10 Faucets

    Single-lever mixing-typefaucets, which are easilyoperated by hand or elbow,are recommended. Faucetswith push buttons are alsoconvenient.

    The clearance betweenthe grip of the tap and anyadjacent vertical surfaceshould not be less than 35mm.

    The space between twotaps should not be lessthan 0.20 m.

    The left tap should beconnected to the hot watersupply.

    Telephone fixtures with acord at least 1.50 m longare recommended for usein showers and bath-tubs.These can be hand-held orfixed at an adjustableheight between 1.20 m and1.80 m from the floor to suitall users.

    46

  • 7/29/2019 Design Consideration PWD

    47/59

    3.11 Flooring

    Rest rooms must nothave doorsteps. Thegradient of the floor shouldbe as low as possible.

    Thresholds should beavoided. When inevitable,the maximum thresholdheight should be 20 mm(see Doors).

    Flooring materials shouldbe skid-proof and easy toclean.

    The floor should be well-drained and provided withadequate waterproofing.

    3.12 Alarms

    Rest rooms should beequipped with an alarmsystem.

    3.13 Pipes

    All exposed hot waterpipes should be insulatedor covered.

    It is preferable that pipesbe fitted in the wall.

    4. EXISTING

    CONSTRUCTIONS

    4.1 Public rest rooms

    For accessible buildings, atleast one accessible unisexrest room should beprovided per facility.

    4.2 Water-closets

    To obtain an accessibletoilet combine two adjacent

    47

  • 7/29/2019 Design Consideration PWD

    48/59

    water-closet and the mutualpartition, provided that thenumber of remainingfixtures is sufficient for thefloor population.

    4.3 Urinals

    Existing high urinals neednot be replaced ifaccessible toilet fixtures areavailable.

    One urinal per rest roomcan be lowered.

    4.4 Rest room vestibules

    For narrow vestibules,replace doors withautomatic door openers oruse swing clear hinges.

    Doors that restrictmanoeuvring space, shouldbe removed so long as thisdoes not inhibit privacy.

    4.5 Grab bars

    If grab bars are notprovided in the initialconstruction, walls shouldbe reinforced to withstandloads.

    4.6 Accessories

    Rest room accessorieslocated at a maximumheight of 1.40 m need notbe modified if they areaccessible.

    4.7 Mirrors

    If existing mirrors are toohigh, they can be tilted or afull-length mirror can beinstalled on another wall.

    48

  • 7/29/2019 Design Consideration PWD

    49/59

    Notes:

    (1) Toilet seats, bidets,shower seats and bath-tubseats are required to be

    mounted at the sameheight of the wheelchairseat, i.e. between 0.45mand 0.50 m above floorlevel.

    (2) Grab bars aremanufactured in variousdimensions and shapes.They can either be wall-mounted or floor-mounted.Retractable bars are alsoavailable.

    49

  • 7/29/2019 Design Consideration PWD

    50/59

    APPENDIX ONE: IMPLEMENTATION CHECKLISTS

    I. TROUBLESHOOTING

    1. Wheelchair users

    Problem Measure

    Overcoming differences in levelbetween road and pavement

    Install curb ramps

    Bridging great differences in heightusually tackled by providing stairs

    Provide ramps, wide elevator cabs orplatform lifts

    Manoeuvring in tight spaces Provide wide routes and spaces

    Passing through narrow dooropenings and over high thresholds

    Provide sufficiently wide dooropenings with low levelled thresholds ornone at all

    Reaching high-mounted controls andobjects

    Provide low-mounted controls

    Manoeuvring in rest rooms Install grab bars, bath-tub and

    shower seats

    2. People with limited walking abilities

    Problem Measure

    Overcoming differences in level Provide curb ramps, ramps, elevatorsor platform lifts

    Manoeuvring in situations requiringspeed

    Increase the pedestrian crossing timeinterval

    Increase the opening interval ofelevators and automatic doors

    Climbing stairs and ramps Provide handrails for gripping

    Manoeuvring in rest rooms Provide sufficiently wide rest rooms

    Provide grab bars, bath-tub and ashower seat

    50

  • 7/29/2019 Design Consideration PWD

    51/59

    Passing through narrow dooropenings and over high thresholds

    Provide sufficiently wide dooropenings with low beveled thresholdsor none at all

    3. People with limited use of hands or arms

    Problem Measure

    Opening heavy doors Use automatic or easy-to-open doors

    Gripping door knobs Use lever-type door handles

    Gripping faucets Use lever-type or push-buttonsfaucets

    4. The sightless

    Problem Measure

    Orientation Provide guide strips within thepathway surface

    Provide raised curbs and other

    detectable guiding elementsProvide tactile marking strips to

    indicate changes in direction and thelocation of stairs and ramps

    Identifying obstructions within thepath of travel

    Provide textured paving or tactilemarking strips around obstructions

    Crossing roads Provide audible traffic signals

    Manoeuvring in elevators Provide audible signals and callbuttons with tactile text

    Recognizing emergency situations Provide audible alarm signals

    Locating exit doors and stairs Provide tactile marking around theknobs of exit doors and the handrails ofexit

    51

  • 7/29/2019 Design Consideration PWD

    52/59

    5. The partially sighted

    Problem Measure

    Identifying obstructions within thepath of travel Provide bright-coloured markings orsignals to identify obstructions

    Orientation Provide clearly legible lettering andsufficiently large dimensions fordirection signs

    Crossing roads Provide audible traffic signals

    Manoeuvring in elevators and inemergency situations

    Use contrasting colour for doors,handrails, tactile signs, etc

    Locating facilities Provide alarm signals

    6. The hearing impaired

    Problem Measure

    Crossing roads Provide clearly visible coloured signs

    and traffic signals

    Managing in situations involving theuse of speech messages, verbaltransmission and interaction

    Use clearly written messages,especially in emergency situationsInstall induction loops in assembly hallsand in public telephones

    Not hearing door, elevator andemergency

    Provide flashing light signals

    52

  • 7/29/2019 Design Consideration PWD

    53/59

    APPENDIX TWO: IMPLEMENTATION CHECKLISTS

    ANTHROPOMETRICS

    Dimensional data varies from oneperson to another, and the averagedimensions vary from one country toanother. The dimensions of theindividual human being vary with time.The tables below provide a range ofdimensions derived from variousstudies. The given measurements takeinto consideration size variationbetween males and females as well asbetween different persons of the samesex.

    Wheelchair Dimensions (fig.1)

    Dimensions shown in the figure are of aconventional manual wheelchair. Thelarger, encircled dimensions refer toelectric wheelchairs.

    Fig.1

    53

  • 7/29/2019 Design Consideration PWD

    54/59

    Dimensional data to a normal person(fig. 2)

    Height 1.50 m - 1.90 m

    Eye 1.40 m - 1.75 m

    Shoulder 1.20 m - 1.55 m

    Fig. 2

    Dimensional data of a wheelchair user

    Fig. 3

    54

  • 7/29/2019 Design Consideration PWD

    55/59

    Reaching zones of a normal person(fig. 4)

    Max. Reach Up 1.85 m - 2.10 m

    Oblique Reach

    Up 1.65 m - 2.00 m

    Forward Reach 1.30 m - 1.45 m

    Fig. 4

    Vertical reaching zones of a wheelchair user

    Fig. 5

    Horizontal forward reach of awheelchair user (fig. 6)

    Eye 1.16 m - 1.33 mShoulder 0.99 m - 1.14 m

    Fig. 6

    55

  • 7/29/2019 Design Consideration PWD

    56/59

    Common reaching zone

    Fig. 7

    Field of Vision

    Fig.8

    56

  • 7/29/2019 Design Consideration PWD

    57/59

    Pathway dimensions

    Visually impaired personusing a long white cane.

    Person using a cane Persons using crutches

    Detectable path dimension

    Fig. 9

    57

  • 7/29/2019 Design Consideration PWD

    58/59

    Wheelchair manoeuvring space

    Fig. 10

    58

  • 7/29/2019 Design Consideration PWD

    59/59

    Manoeuvring at doors

    Fig 11.