HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 1
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideGeneral Information 2
Description 3
Pineclad & Pinetrim XT Vertical Weatherboard Profiles 3
Optional Exterior Pineclad & Pinetrim XT Vertical Weatherboard Profiles 3
Information For Designers 5
Skills Required 5
Considerations When Designing 5
Information For Installers 6
Skills Required 6
Handling 6
Storage 6
Health & Safety 6
Tools Required 6
Installation Requirements 7
Framing & Flexible Underlay or Rigid Air Barrier 7
Fixings 7
Fixing of Structural Battens 8
Aluminium Joinery 8
Weatherboards 8
Ground Clearances 9
Finishing 9
Typical Details 9
Hume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 2
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
General Information
This document is for designers and installers to use to help in the specification and installation of the Pineclad and Pinetrim XT Vertical
Weatherboard External Cladding Systems (the systems).
Pineclad
• IsmanufacturedinNewZealandfromlocallysourcedFSCcertifiedRadiataPine
• IstreatedtohazardclassH3.1withalightorganicsolventpreservative(LOSP)
• Componentsaresuppliedpaintedwithanoil-basedprimer.
Pinetrim XT
• IsmanufacturedinChinafromFSCcertifiedRadiataPinesourcedfromanumberofsourcesincludingNewZealand
• IstreatedtohazardclassH3.1withLOSP
• Componentsaresuppliedpre-sandedandpaintedwithathree-coatacrylicprimerandundercoatsystem.
This document must be read in conjunction with
• HumePinePineclad and Pinetrim XT Vertical Weatherboard External Cladding Systems pass™. This document defines the scope
ofuseandlimitationsforthesystemsandensuresthatthesystemsareusedwithinthescopeoftheCodeMarkCertification.
• HumePinePineclad and Pinetrim XT Care & Maintenance.Thisdocumentdescribeshowthesystemsshouldbemaintained
to ensure ongoing performance.
• HumePinePineclad & Pinetrim XT Horizontal and Vertical Weatherboard External Cladding Systems Warranty.
• HumePineCodeMark Design & Installation Declarations.
• MBIE[January2017]Acceptable Solutions and Verification Methods for New Zealand Building Code (NZ Building Code) Clause
E2 External Moisture(refertowww.building.govt.nz).
• DepartmentofBuildingandHousing(DBH)June2006.Constructing Cavities for Wall Claddings(refertowww.building.govt.nz).
• BRANZBulletinBU468[December2005] Fixing Timber Weatherboards (refertowww.branz.co.nz).
• BRANZ[May2015]Good Practice Guide: Timber Cladding (refertowww.branz.co.nz).
• BRANZBulletinBU582[April2015] Structurally Fixed Cavity Battens (refertowww.branz.co.nz).
Whenapplyingforabuildingconsent,theHumePinedocumentsalongwithacopyofthecurrentCodeMarkCertificateofConformity
shouldbeincluded.ThesignedHumePineCodeMarkInstallationDeclarationshouldbesubmittedwiththecodecompliancecertificate
(CCC) application.
Alldocumentsareavailablefromwww.humepine.nz.
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 3
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
28mm Scotia
Radius 28mm
8mm
14mm
35mm Scotia
Radius 35mm
Cover35mm
8mm
18 x 18mm Eavesmould
18mm
45˚5mm
18mm
40 x 27mm Eavesmould
40mm
27mm
10mm45˚
40mm Rustic Plug
25mm
40mm
9mm
Radius 12mm
12mm
12mm Quad
Radius 18mm
18mm
18mm Quad
30mm Bevelled Cornice
10mm
30mm
18mm
40mm Bevelled Cornice
10mm
40mm
18mm
60 x 18mmScriber
18mm
60mm
40 x 18mmScriber
18mm
40mm
30 x 15mmScriber
30mm
15mm
40 x 10mmScriber
10mm
Radius 6mm
40mm
4mm
6mm52mm
65mm Sill
65mm
2mmRounds
37mm
24 x 19mm Beazley Mould
24mm
19mm
35mm
29mm
Beazley Sill
33mm
16mm 8mm 16mm8mm230mm
230 x 18mm
18mm
16mm 8mm 16mm8mm180mm
180 x 18mm
18mm
16mm 8mm 16mm8mm
18mm
280mm
280 x 18mm
16mm 8mm 16mm8mm
18mm
135mm
135 x 18mm
16mm 8mm 16mm8mm
29mm
135mm
135 x 29mm
16mm 8mm 16mm8mm
29mm
280mm
280 x 29mm
16mm 8mm 16mm8mm
29mm
230mm
230 x 29mm
16mm 8mm 16mm8mm
29mm
180mm
180 x 29mm
9mm
3mm
7mm
6mm
28mm
3mm
3mm
15m
m
6mm
10m
m
3mm 9mm
180mm
180 x 18mm Vertical Shiplap (145mm Cover)
3mm
7mm
6mm
3mm
15m
m
6mm
10m
m
9mm
28mm
3mm3mm 9mm
135mm
135 x 18mm Vertical Shiplap (100mm Cover)
18mm
18mm
18 x 18mm D4S
24mm
24mm
24 x 24mm D4S
3mmRound
6mm
8mm
6.5mm
6.5mm
2mm
18mm
83mm
83 x 18mm Universal Box Corner
3mmRounds
10mm 7mm
7mm18mm
100mm
100 x 18mm External Box Corner
3mmRound
7mm
10mm
5mm
6mm
18mm
100mm
100 x 18mm Internal Box Corner
28mm Scotia
Radius 28mm
8mm
14mm
35mm Scotia
Radius 35mm
Cover35mm
8mm
18 x 18mm Eavesmould
18mm
45˚5mm
18mm
40 x 27mm Eavesmould
40mm
27mm
10mm45˚
40mm Rustic Plug
25mm
40mm
9mm
Radius 12mm
12mm
12mm Quad
Radius 18mm
18mm
18mm Quad
30mm Bevelled Cornice
10mm
30mm
18mm
40mm Bevelled Cornice
10mm
40mm
18mm
60 x 18mmScriber
18mm
60mm
40 x 18mmScriber
18mm
40mm
30 x 15mmScriber
30mm
15mm
40 x 10mmScriber
10mm
Radius 6mm
40mm
4mm
6mm52mm
65mm Sill
65mm
2mmRounds
37mm
24 x 19mm Beazley Mould
24mm
19mm
35mm
29mm
Beazley Sill
33mm
16mm 8mm 16mm8mm230mm
230 x 18mm
18mm
16mm 8mm 16mm8mm180mm
180 x 18mm
18mm
16mm 8mm 16mm8mm
18mm
280mm
280 x 18mm
16mm 8mm 16mm8mm
18mm
135mm
135 x 18mm
16mm 8mm 16mm8mm
29mm
135mm
135 x 29mm
16mm 8mm 16mm8mm
29mm
280mm
280 x 29mm
16mm 8mm 16mm8mm
29mm
230mm
230 x 29mm
16mm 8mm 16mm8mm
29mm
180mm
180 x 29mm
9mm
3mm
7mm
6mm
28mm
3mm
3mm
15m
m
6mm
10m
m
3mm 9mm
180mm
180 x 18mm Vertical Shiplap (145mm Cover)
3mm
7mm
6mm
3mm
15m
m
6mm
10m
m
9mm
28mm
3mm3mm 9mm
135mm
135 x 18mm Vertical Shiplap (100mm Cover)
18mm
18mm
18 x 18mm D4S
24mm
24mm
24 x 24mm D4S
3mmRound
6mm
8mm
6.5mm
6.5mm
2mm
18mm
83mm
83 x 18mm Universal Box Corner
3mmRounds
10mm 7mm
7mm18mm
100mm
100 x 18mm External Box Corner
3mmRound
7mm
10mm
5mm
6mm
18mm
100mm
100 x 18mm Internal Box Corner
Description
Thesystemscomprisetimberweatherboards,fasciaboards,andassociatedsystemmouldingprofilesmanufacturedfromfinger-jointed,
gluelaminated,clearradiatapineandcastellatedcavitybattens.
Thefollowingareavailable:
• 18mmthickweatherboards,availablein135mmand180mmwidthsprofiledtoprovidea25mmrebateensuringa2mmgapthat
allowsforexpansion.
• Fasciaboardsavailablein18mmand29mmthicknessesandwidthsof135mm,180mm,230mm,and280mm.
• MouldingprofilesofBevelledCornice,Quad,Scotia,Scriber,D4S,D4SEavesMould(witharissededge),WeatherGroovedBoxed
Corners and Sill.
• 45x19mmfinger-jointedH3.1LOSPradiatapinecastellatedcavitybattens
• Custom-madeweatherboards,fasciaboards,andmouldingprofilesareavailableonrequest.
Pineclad & Pinetrim XT Vertical Weatherboard Profiles
Optional Exterior Pineclad & Pinetrim XT Vertical Weatherboard Profiles
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 4
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
28mm Scotia
Radius 28mm
8mm
14mm
35mm Scotia
Radius 35mm
Cover35mm
8mm
18 x 18mm Eavesmould
18mm
45˚5mm
18mm
40 x 27mm Eavesmould
40mm
27mm
10mm45˚
40mm Rustic Plug
25mm
40mm
9mm
Radius 12mm
12mm
12mm Quad
Radius 18mm
18mm
18mm Quad
30mm Bevelled Cornice
10mm
30mm
18mm
40mm Bevelled Cornice
10mm
40mm
18mm
60 x 18mmScriber
18mm
60mm
40 x 18mmScriber
18mm
40mm
30 x 15mmScriber
30mm
15mm
40 x 10mmScriber
10mm
Radius 6mm
40mm
4mm
6mm52mm
65mm Sill
65mm
2mmRounds
37mm
24 x 19mm Beazley Mould
24mm
19mm
35mm
29mm
Beazley Sill
33mm
16mm 8mm 16mm8mm230mm
230 x 18mm
18mm
16mm 8mm 16mm8mm180mm
180 x 18mm
18mm
16mm 8mm 16mm8mm
18mm
280mm
280 x 18mm
16mm 8mm 16mm8mm
18mm
135mm
135 x 18mm
16mm 8mm 16mm8mm
29mm
135mm
135 x 29mm
16mm 8mm 16mm8mm
29mm
280mm
280 x 29mm
16mm 8mm 16mm8mm
29mm
230mm
230 x 29mm
16mm 8mm 16mm8mm
29mm
180mm
180 x 29mm
9mm
3mm
7mm
6mm
28mm
3mm
3mm
15m
m
6mm
10m
m
3mm 9mm
180mm
180 x 18mm Vertical Shiplap (145mm Cover)
3mm
7mm
6mm
3mm
15m
m
6mm
10m
m
9mm
28mm
3mm3mm 9mm
135mm
135 x 18mm Vertical Shiplap (100mm Cover)
18mm
18mm
18 x 18mm D4S
24mm
24mm
24 x 24mm D4S
3mmRound
6mm
8mm
6.5mm
6.5mm
2mm
18mm
83mm
83 x 18mm Universal Box Corner
3mmRounds
10mm 7mm
7mm18mm
100mm
100 x 18mm External Box Corner
3mmRound
7mm
10mm
5mm
6mm
18mm
100mm
100 x 18mm Internal Box Corner
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 5
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Information For Designers
Skills Required
YoumusthaveknowledgeofthesystemsandaccesstoallHumePinetechnicalinformation(refertowww.humepine.nz)andall
relevantregulatoryinformation(refertowww.building.govt.nz).
Whererestrictedbuildingwork(RBW)provisionsapply,youmustbeabletomeetyourobligations.
Considerations When Designing
Youmustensurethattheprojectfallswithinthescopeofthesystems(refertotheHumePinePinecladandPinetrimXTVertical
Weatherboard External Cladding Systems pass™).
PleasenotethatwhilstE2/AS1allowsforfacefixedinstallationwheretheriskmatrixislessthanorequalto6,HumePinerecommends
thatthesystemsarealwaysinstalledoveradrainedandventilatedcavity.
Youmustalsoconsiderthefollowingindicativelist:
• Exposurezones/durabilityrequirementsofallfastenings;
• Windzone/specificwindpressure;
• Climatezone;
• Locationofbuildingon-siteandproximitytorelevantboundaries;
• ComplianceofthebuildingworkwithallrelevantprovisionsoftheNewZealandBuildingCode,includingbutnotlimitedto
• Suitabilityoftheexistingbuilding,
• Structuralframingrequirementsduringtheconstructionphaseandoncecompleted;
• RiskcalculationusingtheE2/AS1riskmatrix;and
• Othermaterialslikelytoaffecttheproduct’sperformance.
Thedetailsdonotrefertospecifictradebrandsoffixings,buildingwrap,rigidairbarrier,orsealingtape.Youmustensurethatselected
productscomplywiththeNewZealandBuildingCodeandaresuitableforthespecificbuildingproject.
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 6
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Information For Installers
Skills Required
YoumusthaveknowledgeofthesystemsandaccesstoallHumePinetechnicalinformation(refertowww.humepine.nz)and
allrelevantregulatoryinformation(refertowww.building.govt.nz).
WhereRBWprovisionsapply,youmustensurethatyouareabletomeetyourobligations.
Handling
Hume Pine (NZ) Ltd. recommends that the products are unloaded by hand. Long lengths should be carried on edge, not on their flat.
Ifmechanicalmeansareused,ensurethatthereisaminimumoftwowell-spacedpointstoavoidexcessivebendingorsagging.
Where using a crane, you may need to consider a spreader bar.
Storage
Ifstoredon-site,theproductmustbestackedflatonadrysurface,atleast150mmoffthegroundandundercover.Thedunnage
strapped to the bottom of the packet and associated packaging material is for transport purposes only and is not suitable for use
ason-sitestorage.
Ensuretheareawheretheproductisstoredisdry,well-ventilated,andoutofdirectsunlight.
Health & Safety
Takeallnecessarystepstoensureyoursafetyandthesafetyofothers,including:
• Ensuringadequateventilationormechanicaldustextractionwhencuttingordrilling;
• Ensuringthetimberiswellsupportedwhencuttingandnailing;
• Wearingappropriatesafetyequipment,clothingandfootwear;
• Usingalltoolsinaccordancewithrelevantinstructionmanuals;
• Planningandmonitoringasafeapproachforworkingatheightincludingselectingandusingtherightequipment;
• Clearingtheworkareaofanyobstructionsbeforeworkstarts.
Forfurtherinformationreferto:
• WorkSafe[July2018]Small Construction Sites, The Absolutely Essential Health and Safety Toolkit.
• WorkSafe[December2016]Health and Safety at Work, Quick Reference Guide.
Thesedocumentsareavailableatwww.worksafe.govt.nz.
Tools Required
Generalcarpentryandwoodworkingtoolsareallyouwillneedtoinstallthesystem.
Note:Powerdrivenailgunsmaybeusedtoinstallcavitybattens.
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 7
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Installation Requirements
Refer to the typical details at the end of this Design and Installation Guide to assist in the installation of the systems.
Thefollowingrequirementsmustbesatisfied:
Framing & Flexible Underlay or Rigid Air Barrier
Priortoinstallingthesystemsensure:
• TheframingandunderlayorrigidairbarrierhasbeeninstalledsothatitcomplieswiththeNewZealandBuildingCode(fornew
buildingwork)orissuitablefortheinstallationofthesystems(forexistingbuildings);
• FramingtolerancesareinaccordancewithSection2.1,NZS3604:2011;
• Moisturecontentoftheframingisnogreaterthan18%;
• Theframingandunderlayhavebeeninstalledinaccordancewithrelevantspecificationorsupplierinformation;
• Arigidairbarrier(inaccordancewithTable23ofE2/AS1)hasbeeninstalledinunlinedgablesandwalls;
• UnderlayinaccordancewithParagraph9.1.3.4ofE2/AS1hasbeeninstalledinattachedgarages.
Fixings
Ensurethatallmaterialsarecompatibleinaccordancewith:
• Table20E2/AS1;
• Table21ofE2/AS1;
• Table22ofE2/AS1.
Fixingsandfixingmaterialsmustbeinaccordancewith:
• NZS3604:2011;
• Table24ofE2/AS1;
• Paragraph2.2ofE2/AS1.
APVCtapebondbreakmustbeprovidedbetweenH3.1battensandanyflashing.
Soakersandflashingsmustbefixedinaccordancewith:
• Section4andTable6.12ofNZS3604:2011;
• Section9ofE2/AS1.
AcavityclosurestripmustbeinstalledinaccordancewithParagraph9.1.8.3ofE2/AS1.
Allnailfixingsshouldbepre-drilledwithadiameteraminimumof1mmsmallerthanthenailgauge.
Allnailsmustbefilledafterinstallationtopreventmoisturedamage,priortocoatingofthesystem.
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 8
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Fixing of Structural Battens
HumePinesupplycastellatedcavitybattens;45mmx19mmgauged,bevelledtopandbottomedgeandtreatedtoH3.1aspart
of the systems.
ThesebattensmustbeinstalledinaccordancewithBRANZBulletinBU582[April201]Structurally Fixed Cavity Battens
(refertowww.branz.co.nz).
Battensmustbestructurallyfixedtothewallframingat300mmcentresor1nailperstudand2nailspernogwith:
• 60mmx2.8mmgalvanisedjoltheadnails,or
• Power-driven60mmx2.87mmgalvanisednails,or
• Power-driven64mmx2.8mmstainlesssteelannular-groovednails.
Aluminium Joinery
Aluminiumjoineryandflashingsmustbeinstalledinaccordancewiththemanufacturer’sinstructions.
A7.5mm–10mmnominalgapmustbeleftbetweentherevealandwallframingtoallowaPEFrodandairsealtobeinstalled
inaccordancewithParagraph9.1.6ofE2/AS1.
Weatherboards
Priortoinstallingthesystems:
• Ensurethemoisturecontentoftheproductsisnogreaterthan16%.Allowtodryifnecessary.
• Checktheproductsforanydefectsordamageandremoveanydirt,dust,orstones.
• Ensureallcutends,edges,andareaswherethesuppliedcoatinghasbeendamagedaresandedsmooth,endsealedandrecoated.
For Pinetrim XT only quality acrylic primer and top coat systems may be used.
• HumePinerecommendsthatallnailfixingsarepre-drilled,especiallyinareasaroundjoinsandtheendofboardswithadiameter
a minimum of 1mm smaller than the nail gauge.
Installingthesystems:
• Weatherboardsaretobefixedwith:
• Galvanized60mmx2.80mmjoltheadnailsembeddedaminimumof20mmintowallframingwhereinstalledover
structurally fixed battens, or
• Galvanized75mmx3.15mmjoltheadnailsembeddedaminimumof30mmintowallframingwherethebattenisnot
structurally fixed.
• Checkthataminimum2mmgapbetweenweatherboardshasbeenachieved.
• Weatherboardsshouldbefixedsothattheweathergrooveontherebatefaceoftheweatherboardmatchestheweathergroove
in the back edge of the lap face.
• Handnailingisrecommendedasnailgunscancausedamagetothefaceandbackoftheboard.
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 9
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
• Nailatanupwardangletopreventwatermovementdownthenailintothewallspace.Allnailsshouldbepunchedtoadepth
of3mm–4mm.Holesshouldbefilledimmediatelywithasuitableexteriorfiller.Allnailsmustbefilledimmediatelyafter
installation,withasuitableexteriorfiller,topreventmoisturedamage,priortocoatingofthesystem.
Ground Clearances
• FinishedfloorlevelmusthaveminimumclearancesinaccordancewithE2/AS1andNZS3604:2011.
• Weatherboardsmustoverhangtheconcreteslabandbottomplatebyaminimumof50mminaccordancewithTable18ofE2/AS1.
• Thebottomedgeoftheweatherboardsmustbe:
• Keptclearofadjacentsurfaces,and
• Aminimumof35mmabovethetop-surfaceofadjacentflashingsatdeckorlowpitchroof/walljunctions.
Finishing
• ForPineclad,aprimerundercoatandtwotopcoatsofhigh-gradeacrylicoroil-basedpaintmustbeappliedtothesystem.
• ForPinetrimXT,twotopcoatsofhigh-gradeacrylicpaintmustbeappliedtothesystem.
• Paintmustbeappliedinaccordancewiththemanufacturer’sinstructions.Darkcolours,withaLightreflectiveValue(LRV)less
than45%shouldbeavoidedastheyabsorbheatandcouldcauseexcessivemovement,distortion,orresinbleed.
Forfurtherinformationreferto:
• NZS2311:2017Guide to the Painting of Buildings
Typical Details
Thefollowingtypicaldetailsandnailingpatternshavebeenpreparedtoassistinthespecificationandinstallationofthesystems
anddemonstratecompliancewiththeNZBuildingCode.ThisinformationisconsistentwithAcceptableSolutionE2/AS1,BRANZ
GoodPracticeGuideforTimberCladdingandthetestassemblyusedtotesttoE2/VM1.
Thedetailsaredescribedastypicalastherearedesignoptionsandminorvariationsthatmayberequired.Whereusedinconjunction
withothercladdingsystems,thedesignermustassurethemselvesthatthejunctionwillmeetallrelevantBuildingCodeprovisions
includingthoseofClauseE2ExternalMoistureoftheNZBuildingCode.
Detailssupplied:
• Fig1: TypicalFixingDetail(A)
• Fig2: TypicalFixingDetail(B)
• Fig3: FloorJunctionDetail
• Fig4: InternalCorner(ButtJoint)Detail
• Fig5: InternalCorner(Box&Scriber)Detail
• Fig6: ExternalCorner(ButtJoint)Detail
• Fig7: ExternalCorner(Box&Scriber)Detail
• Fig8: TypicalDoorInstallation(ConcreteFloor)
• Fig9: WindowHeadDetail
• Fig10:WindowJambDetail
• Fig11:WindowSillDetail
• Fig12:EaveJunctionDetail
• Fig13:Cladding/RoofJunctionDetail
• Fig14:ParapetJunctionDetail
• Fig15:ParapetSaddleFlashingDetail
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 10
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Pineclad & Pinetrim XT External Vertical Cladding System
Flexible Building Wrap or Rigid Air Barrier (RAB)
Framing To NZS3604 Horizontal Nogs @ Maximum480mm CRS
Clinch Nail Optional
Hume Pine, H3.1, 45mm x 19mm Castellated StructuralTimber Cavity Battens at Maximum 480mm CRS.Battens Fixed With 60mm x 2.8mm Galvanised JoltHead Nails, 1 Per Stud & 2 Per Nog.
60 x 2.8mm Galv JH Nail (Punch & Fill)
Typical Fixing Detail (B)
(Fig 2)
Pineclad & Pinetrim XT External Vertical Cladding System
Flexible building wrap or rigid air barrier (RAB)
Framing to NZS3604 horizontal nogs @ maximum 480mm CRS
60mm x 2.8mm galv JH nail (punch & fill)
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Typical Fixing Detail (A)
(Fig 1)
Typical Fixing Detail (A) (Fig 1)
Typical Fixing Detail (B) (Fig 2)
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 11
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Floor Junction Detail (Fig 3)
Internal Corner (Butt Joint) Detail (Fig 4)
FLOOR JUNCTION DETAIL
(Fig 3)
Pineclad & Pinetrim XT ExternalVertical Cladding System
Flexible building wrap lap or rigid air barrier(RAB) over “Z” flashing
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mmgalvanised jolt head nails, 1 per stud & 2 per nog.
Flooring
Proprietary “Z” flashing
Cavity closer / vent strip
60mm x 2.8mm galvanised jolt head nails (punch & fill)
Internal Corner (Butt Joint) Detail
(Fig 4)
Framing to NZS3604 horizontal nogs @ maximum 480mm CRS
Flexible building wrap lap or rigid air barrier (RAB)
Sealant
60 x 2.8mm galvanised jolt head nails
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Proprietary back flashing
Pineclad & Pinetrim XT External Vertical Cladding System
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 12
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Internal Corner (Box & Scriber) Detail
(Fig 5)
Framing to NZS3604 horizontal nogs @ maximum480mm CRS
Flexible building wrap lap or rigid air barrier (RAB)
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Proprietary back flashingSealant
30mm x 15mm scriber (optional)
Pineclad & Pinetrim XT External Vertical Cladding System
Hume Pine 100mm x 18mm Universal Box CornerHume Pine 82mm x 18mm Universal Box Corner
60 x 2.8mm galvanised jolt head nails
Internal Corner (Box & Scriber) Detail (Fig 5)
External Corner (Butt Joint) Detail (Fig 6)
External Corner (Butt Joint) Detail
(Fig 6)
Flexible building wrap lap or rigid air barrier (RAB)
Sealant
Pineclad & Pinetrim XT External Vertical Cladding System
Hume Pine, H3.1, 45mm x 20mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Proprietary 50mm x 50mm back flashing
Solid corner cavity batten
Framing to NZS3604 horizontal nogs @ maximum480mm CRS
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 13
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
External Corner (Box & Scriber) Detail (Fig 7)
Typical Door Installation (Concrete Floor) (Fig 8)
External Corner (Box & Scriber) Detail
(Fig 7)
Flexible building wrap lap or rigid air barrier (RAB)
30mm x 15mm scriber (optional)
Pineclad & Pinetrim XT External Vertical Cladding System
30mm x 15mm scriber (optional)
Proprietary 50mm x 50mm back flashing
Framing to NZS3604 horizontal nogs @ maximum480mm CRS
Hume Pine 100mm x 18mm External Box Corner
Hume Pine 82mm x 18mm Universal Box Corner
Solid corner cavity batten
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Typical Door Installation
(Fig 8 Concrete Floor)
Cavity close / vent strip to E2/ASI
Seal rebate
Timber packer
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity batten
Pineclad & Pinetrim XT External VerticalCladding System
Aluminium door joinery to NZS4211
Aluminium door joinery support bar
40mm masonry nail or 8mm Ø masonry anchor
Concrete floor slab
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 14
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Window Head Detail (Fig 9)
Window Jamb Detail (Fig 10)
Window Jamb Detail
(Fig 10)
Flashing tape over building wrap
Framing to NZS3604 horizontal nogs @ maximum480mm CRS
60mm x 2.8mm galvanised jolt head nails (punch & fill)
Pineclad & Pinetrim XT External Vertical Cladding System
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Air seal / backing rod
Aluminium joinery to NZS4211
Flexible building wrap or rigid air barrier (RAB)
Window Head Detail
(Fig 9)
Flashing tape over building wrap
Flexible building wrap or rigid air barrier (RAB)
60mm x 2.8mm galvanised jolt head nails
Stop end
Pineclad & Pinetrim XT External Vertical Cladding System
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Sealant for v/high & extra high wind zones
Air seal / backing rod
Aluminium joinery to NZS4211
6mm
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 15
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Window Sill Detail (Fig 11)
Eave Junction Detail (Fig 12)
Window Sill Detail
(Fig 11)
Flashing tape over building wrap
60mm x 2.8mm galvanised jolt head nails (punch & fill)
Pineclad & Pinetrim XT External Vertical Cladding System
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Air seal / backing rod
Aluminium joinery to NZS4211
Flexible building wrap or rigid air barrier (RAB)
Framing to NZS3604 horizontal nogs @ maximum 480mm CRS
Sill tray to E2/AS1 (optional)
Eave Junction Detail
(Fig 12)
Sealant
60mm x 2.8mm galvanised jolt head nails (punch & fill)
Pineclad & Pinetrim XT External Vertical Cladding System
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Soffit framing
Soffit lining
Flexible building wrap or rigid air barrier (RAB)
Framing to NZS3604 horizontal nogs @ maximum 480mm CRS
Hume Pine 18mm x 18mm Eaves Mould
20mmminimum
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 16
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Cladding/Roof Junction Detail (Fig 13)
Parapet Junction Detail (Fig 14)
Cladding / Roof Junction Detail
(Fig 13)
60mm x 2.8mm galvanised jolt head nails (punch & fill)
Pineclad & Pinetrim XT External Vertical Cladding System
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Sealant
Soffit lining Soffit framing
Flexible building wrap or rigid air barrier (RAB)
Framing to NZS3604 horizontal nogs @ maximum 480mm CRS
Hume Pine 18mm x 18mm Eaves Mould
Parapet Junction Detail
(Fig 14)
Shaped block to suit
Pineclad & Pinetrim XT External Vertical Cladding System
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Metal cap flashing over flexible building wrap5̊ minimum slope
Flexible building wrap or rigid air barrier (RAB) over timber framing
Timber framing in accordance with NZS3604
Metal saddle flashing to E2/ASI
HUME PINE (NZ) LTD: | 210 Te Ngae Road, Rotorua | [email protected] | 0508 111 000 | www.humepine.nz | Page 17
CM Vertical Design and Installation Guide V1 | Uncontrolled in printed format.
Design & Installation GuideHume Pine (NZ) Ltd Pineclad & Pinetrim XT Vertical Weatherboard External Cladding Systems
Parapet Saddle Flashing Detail (Fig 15)
Parapet Saddle Flashing Detail
(Fig 15)
Shaped block to suit
Pineclad & Pinetrim XT External Vertical Cladding System
Hume Pine, H3.1, 45mm x 19mm castellated structural timber cavity battens at maximum 480mm CRS. Battens fixed with 60mm x 2.8mm galvanised jolt head nails, 1 per stud & 2 per nog.
Metal cap flashing over flexible building wrap
Flexible building tape over saddle face at wall
Timber framing in accordance with NZS3604
5˚minimum slope
50mm
150mm
200mm
50mm
Fix saddle flashing to building wrap & applyflexible tape to seal edges
Metal saddle flashing to E2/ASI
Flexible building wrap or rigid air barrier (RAB) over timber framing
5˚minimum slope