66
Lightspeed Design, Inc. Reference Manual for DepthQ ® Polarization Modulator: 2012 V2-0-6 2012

DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Embed Size (px)

DESCRIPTION

DepthQ Polarization Modulator Reference Manual 2012

Citation preview

Page 1: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Lightspeed Design, Inc.

Reference Manual for DepthQ

® Polarization Modulator:

2012 V2-0-6

2012

Page 2: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

CONTACT US FOR ASSISTANCE Technical Support: Telephone +1-425-637-2818 Fax +1-425-696-0115 Technical Support Hours: 10:00 AM to 7:00 PM Monday thru Friday PST Write to: [email protected]

Notice:

Lightspeed Design, Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written notice. DepthQ® Polarization Modulator is a trademark of Lightspeed Design, Inc. © 2012 Lightspeed Design, Inc., All Rights Reserved All trademarks are the property of their respective companies.

Page 3: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | i DepthQ® Reference Manual - Table of Contents

Lightspeed Design, Inc. Reference Manual for DepthQ® Polarization Modulator 2012

Table of Contents

DepthQ® Polarization Modulator TM ............................................................................... 3

Overview ....................................................................................................................................... 3

DepthQ® Polarization Modulator Advantages .................................................................................... 4

Polarization ......................................................................................................................................... 5

General System Requirements ............................................................................................................ 5

Polarization Preserving Screen ........................................................................................................ 5

3D Projector ..................................................................................................................................... 5

3D Polarized Glasses ........................................................................................................................ 6

3D Server and Signal Source ............................................................................................................ 6

Getting Started .............................................................................................................................. 7

Important Notes and Notices .............................................................................................................. 7

Polarization Modulator .................................................................................................................. 7

Overview of Components and Optics .................................................................................................. 7

Example Installation Photos .......................................................................................................... 19

Polarization Modulator Control Unit ............................................................................................ 23

Input Signal to Polarization Modulator Control Unit......................................................................... 23

Polarization Modulator Control Unit Menu System .......................................................................... 25

Network Control ............................................................................................................................ 25

Configuring Your Computers IP Address ........................................................................................ 26

Web Interface ................................................................................................................................ 28

Explanation of features – Main Settings ........................................................................................... 30

Input Frequency ............................................................................................................................. 30

Output Voltage .............................................................................................................................. 30

Signal Reversed ............................................................................................................................. 30

Global Phase Shift ......................................................................................................................... 30

Save Settings ................................................................................................................................. 31

Explanation of features – Advanced Settings .................................................................................... 31

B-Delay .......................................................................................................................................... 31

Page 4: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | ii DepthQ® Reference Manual - Table of Contents

Min. 3D Input Frequency (introduced in firmware version 0.40) ................................................... 31

Max. 3D Input Frequency (introduced in firmware version 0.40) .................................................. 31

Description of Phantom Output .................................................................................................... 31

Phantom Output ............................................................................................................................ 32

Phantom System ........................................................................................................................... 32

Phantom Frequency ...................................................................................................................... 32

Save Settings ................................................................................................................................. 32

Explanation of features – Advanced Settings .................................................................................... 33

DHCP Settings (introduced in firmware version 0.40) ................................................................... 33

IP Address ...................................................................................................................................... 34

Network Mask ............................................................................................................................... 34

Communication Port ..................................................................................................................... 34

Recommended Settings for Projectors ............................................................................................. 35

Series 2 DCI Projectors ................................................................................................................... 35

Series1 DCI Projectors .................................................................................................................... 36

Series1 DCI Projectors – Alternative Setting .................................................................................. 37

Industrial Projectors ...................................................................................................................... 38

DepthQ® Technical Specifications ............................................................................. 41

General Specifications ................................................................................................................. 41

Drawings LARGE MOUNT ............................................................................................................. 42

Drawings SMALL MOUNT ............................................................................................................. 56

DepthQ® Timing Process............................................................................................. 60

General Overview ........................................................................................................................ 60

Oscilloscope Measurements .......................................................................................................... 63

DepthQ® Warranty ........................................................................................................ 64

Warranty ..................................................................................................................................... 64

Page 5: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 3 Chapter 1: DepthQ® Polarization Modulator™

DepthQ® Polarization Modulator TM

Overview

The DepthQ® Polarization Modulator utilizes a unique combination of separate liquid crystal elements bonded together, enabling both high polarization efficiency over visible wavelengths from 400 to 750 nm (predominantly achromatic spectral response) as well as fast transition switching speeds (50 μsec at room temperature) between polarization states at frequencies from 120Hz to 400Hz.

By actively alternating between two orthogonal polarization orientations in sync with progressive ‘page-flip’ stereoscopic data, matching polarized eyewear can passively block or transmit light to the viewer's eyes at the appropriate moment. Efficient, high-speed switching between the eyes ensures bright, low-crosstalk, flicker-free operation.

The system includes both the liquid-crystal modulator as well as its control unit. A standard stereoscopic sync output from your graphics card or video projector should be supplied to the control unit, which uses the input to drive the modulator synchronously.

The modulator is available in two sizes: Small, for projectors with apertures <9.84 x 6.11 cm (3.875 x 2.41

in), and Large, for projectors with apertures <17.15 x 9.78 cm (6.75 x 3.85 in).

The optical window is also very heat-tolerant and can operate at temperatures up to 52 degrees Celsius (125 deg F).

The DepthQ® Polarization Modulator is available pre-configured for circular polarization only.

Page 6: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 4 Chapter 1: DepthQ® Polarization Modulator™

DepthQ® Polarization Modulator Advantages

Viewer Comfort

* Passive glasses are very lightweight

* Single-projector solution eliminates possibility of geometric asymmetry between eyes

* No vertical or horizontal parallax problems

* No inconsistency of color or intensity between left and right eye (caused by individual bulbs)

Ease of set-up

* Modulator placement is simple and forgiving - just set it in front of the projector

* No time-consuming alignment of superimposed images required

Lower Cost/Maintenance

* No moving parts

* Less hardware than two projector solutions

* No high-power Infra-Red emitter necessary

* Passive eyewear is inexpensive

Options for Viewing

* Circular polarization models only

* Passive glasses are available in a variety of form factors - from paper to plastic to wire-frame

Versatility

* Enables a wide range of applications - from theme parks & commercial 3D theaters to scientific & industrial visualization

Flexible Pricing

* Pricing model reflects application and use

Page 7: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 5 Chapter 1: DepthQ® Polarization Modulator™

Polarization

A fast polarization modulator comprises fast switching liquid crystal elements designed to rapidly switch the plane of polarization of incident light. Utilization of a unique combination of separate liquid crystal elements stacked together enables both high polarization efficiency over visible wavelengths as well as fast transition switching speeds between polarization states up to 400Hz. Typical 3D projection operates at 120Hz or 144Hz.

Polarization is available in circular.

DepthQ Polarization Modulator, Circular: - The linear input polarizer on the circular modulator is vertical, 90 degrees. - Matching circular glasses orientation: both eyes have the linear element at 0 degrees, 0/0

General System Requirements

The following are the system requirements for a complete passive polarized 3D projection system.

Polarization Preserving Screen

Use of a polarization preserving screen is mandatory.

3D front projection silver screen manufacturers supported (minimum suggested gain 2.2): Harkness Screens, Severtson Corporation, Stewart Film screen, and STRONG / MDI Screen.

3D rear projection polarization preserving screen supported (minimum suggested gain 1.5): Stewart Film Screen.

Other screens may be used, but performance may be effected.

3D Projector

DepthQ polarization must be paired with a well designed “3D-Ready” 3D projector. DepthQ polarization does not work with standard 2D projectors.

Industrial Models which have been tested: DepthQ HDs3D, ProjectionDesign F10 AS3D, Christie Mirage S+3K, Christie Mirage HD6, Christie Mirage M Series, Digital Projection Titan

Cinema (DCI) Models which have been tested: Christie, NEC, and Barco series 1 and 2 models

Maximum Lumens for each model of modulator:

Small Aperture <9.84 x 6.11 cm (3.875 x 2.41 in): 4,000 ANSI lumens maximum Large Aperture <17.15 x 9.78 cm (6.75 x 3.85 in): includes heat mitigation (wire grid): 30,000 ANSI maximum, 18,500 ANSI lumens typical.

Page 8: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 6 Chapter 1: DepthQ® Polarization Modulator™

3D Polarized Glasses

The DepthQ polarization modulator is designed to be compatible with all glasses commonly used worldwide in both the industrial and cinema markets. - Matching circular glasses orientation: both eyes have the linear element at 0 degrees, 0/0 Please consult Lightspeed Design prior to selection of glasses.

3D Server and Signal Source

The DepthQ polarization modulator is compatible with all common signal sources on the market.

For Cinema applications crosstalk elimination may be used. Lightspeed recommends Dolby® Digital Cinema at this time. Ghosting Coefficients with Dolby Server

Left Eye X -0.02 Y -0.02 Z -0.02

Right Eye X -0.02 Y -0.02 Z -0.02

Please consult Lightspeed prior to selection of servers.

Page 9: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 7 Chapter 1: DepthQ® Polarization Modulator™

Getting Started

Important Notes and Notices

Please read these notes prior to installing the DepthQ Polarization Modulator

Item 1) Always fill the DepthQ modulator fully with light; hot spots can burn the polarizer.

Item 2) Always use the provided input cables with ferrite core noise suppressors. Projection lamps may create a high noise environment, which can cause the DepthQ Control Unit to misfire.

Polarization Modulator

Overview of Components and Optics

001a-Overview. What you’ll see when you unpack the main DepthQ® Polarization Modulator box.

001b-Overview. Everything unpacked.

Page 10: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 8 Chapter 1: DepthQ® Polarization Modulator™

002-Connect Actuator to power.

003-Connecting Actuator to Manual Controller

004-Actuator Manual Controller – Down arrow moves modulator in front of lens (towards actuator motor).

Page 11: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 9 Chapter 1: DepthQ® Polarization Modulator™

005-Actuator Manual Controller – Up arrow moves modulator away from lens (away from actuator motor).

006-Connecting Actuator to Automated Controller

007-Moving Actuator control cable connected to drive motor. The black box contains a latching relay which controls the in and out movement of the modulator. The white cable should be connected to the theater’s show control system. Applying 12v DC momentarily between the silver wire (ground) and the white wire will cause the sled to move towards the motor. Applying 12v DC momentarily between ground and the black wire will cause the sled to move away from the motor. Use a momentary (pulse) contact closure signal.

Page 12: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 10 Chapter 1: DepthQ® Polarization Modulator™

008-Close up of moving actuator control latching relay, the bare wires of the white cable connects to the theater’s show control system.

009-White cable connects to theater control system. Applying 12v DC momentarily between ground and the white wire will cause the sled to move towards the motor. Applying 12v DC momentarily between the silver wire (ground) and the black wire will cause the sled to move away from the motor. Use a momentary (pulse) contact closure signal.

010-Actuator under Automated Control

Page 13: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 11 Chapter 1: DepthQ® Polarization Modulator™

011-Slide-Stage Lock-Wheel #1

012-Slide-Stage Lock-Wheel #2

013-Loosen both Slide-Stage Lock-Wheels to adjust positioning of actuator and modulator as required for your projector. Secure in position by tightening both Lock-Wheels. Slide-Stage at farthest “right” when facing screen.

Page 14: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 12 Chapter 1: DepthQ® Polarization Modulator™

014-Slide-Stage at farthest “left” when facing screen.

015-Connect Fan to power (12V Only)

016-This side faces the projector.

Page 15: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 13 Chapter 1: DepthQ® Polarization Modulator™

017-This side faces the screen.

018-Modulator Tilt Down The Modulator must be angled so that it is perpendicular to the light from the projection lens. Most digital theater lenses project down towards the screen. Positioning the modulator perpendicular to the light optimizes crosstalk characteristics.

019-Modulator Tilt Up The Modulator must be angled so that it is perpendicular to the light from the projection lens. Most home projector lenses project up towards the screen, unless hung from the ceiling. Positioning the modulator perpendicular to the light optimizes crosstalk characteristics.

Page 16: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 14 Chapter 1: DepthQ® Polarization Modulator™

020-Digital Cinema (DCI) Projector Sync Connector. This cable connects to the GPIO port of the projector which should be configured to send the stereo synchronization control signal to the modulator. The BNC side connects to the control unit.

021-Modulator Driver Power (12V Only !)

022-Modulator Driver Power

Page 17: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 15 Chapter 1: DepthQ® Polarization Modulator™

023-Modulator Driver Power

024-Modulator Driver Output Cable Connect the right-angled 4-pin mini DIN side to the modulator optics. Connect 6-pin Mini-XLR side to Modulator Electronics.

025-Modulator Driver Output Mini-XLR Connecting to the control unit

Page 18: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 16 Chapter 1: DepthQ® Polarization Modulator™

026-Modulator Driver Connections Close-up

027-Modulator Input - Connecting to the modulator. The 4-pin mini DIN cable connects to the modulator optics. Loosen the connection clamp, rotate aside, connect mini DIN, rotate clamp into place and tighten.

028-Modulator Input Mini DIN cable port, with loosened clamp.

Page 19: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 17 Chapter 1: DepthQ® Polarization Modulator™

029-Modulator Input Mini DIN connector plugged in.

030-Modulator Input Rotate clamp into place and tighten.

031- Computer Sync Connector for non-Cinema applications. 3-pin mini DIN for connection to graphics card for non-cinema applications

Page 20: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 18 Chapter 1: DepthQ® Polarization Modulator™

032-mini DIN Sync Out of Graphics Card 3-pin mini-DIN sync connector (top). For connection to graphics card for non-Cinema applications

Page 21: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 19 Chapter 1: DepthQ® Polarization Modulator™

Example Installation Photos

Small model and projector

Mounting with small actuator and Projection Design projector.

Christie Mirage with high power model

Page 22: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 20 Chapter 1: DepthQ® Polarization Modulator™

Christie HD18 with high power model

Example of mounting on flat surface with no mount.

Mounting on a tripod with NEC Digital Cinema

Page 23: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 21 Chapter 1: DepthQ® Polarization Modulator™

Mounting on Actuator with NEC Digital Cinema

Modulator with wall mounting

Modulator with wall mounting, moving actuator shown.

Page 24: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 22 Chapter 1: DepthQ® Polarization Modulator™

Modulator with rack mounting

Modulator with rack mounting

Modulator with rack mounting

Page 25: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 23 Chapter 1: DepthQ® Polarization Modulator™

Polarization Modulator Control Unit

Input Signal to Polarization Modulator Control Unit

The following is the typical connector for graphic card connections. Refer to manuals of each projector for their specific GPIO configuration for 3D devices.

Connector: 3 pin mini-DIN PIN1 : Not used PIN2 : Ground PIN3 : Stereo Sync Signal (TTL levels)

Connector: BNC (driver side) Center pin : Stereo Sync Signal (TTL levels) Body : Ground

Stereoscopic sync output from NVIDIA Quadro card, ProjectionDesign, Christie Mirage, Digital Projection, NEC DCI, Barco DCI, and Christie DCI projectors have been confirmed.

Page 26: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 24 Chapter 1: DepthQ® Polarization Modulator™

The following is the typical connector for Digital Cinema (DCI) Projectors. Refer to your projector manual for specific GPIO configuration for 3D devices:

Connector: 37 pin GPIO Connector (provided cable) PIN9 : Stereo Sync Signal (open collector) PIN28 : Ground

Connector: BNC (driver side) Center pin : Stereo Sync Signal (open collector) to GPO + Body : Ground to GPO -

Stereoscopic sync output from NEC DCI, Barco DCI, and Christie DCI projectors have been confirmed.

Page 27: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 25 Chapter 1: DepthQ® Polarization Modulator™

Polarization Modulator Control Unit Menu System

The following is the menu system for the control unit, which is accessed via a web browser. Please use the included “Ethernet crossover cable” which is used to connect your computer, laptop, or netbook directly to the control units without a network switch.

Network Control

You can monitor operation and change control unit settings by way of a "web page" style interface. To access this page, you need to connect the control unit to your PC through an existing network or directly to your PC (using the supplied cross-over network cable). From your PC, point your web browser to the IP address of the driver to bring up the monitoring and control web page (above).

Page 28: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 26 Chapter 1: DepthQ® Polarization Modulator™

The control unit network values are shown cycling on the bottom line of the display screen. The IP address is included. If your driver's IP address is 192.168.1.254, then the URL should be http://192.168.1.254

If you do not get a response from the unit try a direct connection to your computer without using any switches or hubs. It is possible your network setup translates the IP address to an improper value.

Configuring Your Computers IP Address

If your computer’s IP address does not already match the first three numbers of the control unit’s IP address, you will need to reconfigure your computers network connection with a proper static IP address. The screen shots below show the process when using Windows 7. The process under Windows Vista and Windows XP is similar.

Page 29: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 27 Chapter 1: DepthQ® Polarization Modulator™

Page 30: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 28 Chapter 1: DepthQ® Polarization Modulator™

Web Interface

Below are pictures of the three screens in the Web Interface. A password is required to access the Advanced and Network Settings pages. The username is “admin” and the password is “depthq”.

Main Settings - 120 Hz Operation Password entry screen. The username is “admin” and the password is “depthq”

Main Settings - 144 Hz DCI Operation Advanced Settings

Page 31: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 29 Chapter 1: DepthQ® Polarization Modulator™

Network Settings Main Settings - 144 Hz DCI Operation Alternate Settings

Page 32: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 30 Chapter 1: DepthQ® Polarization Modulator™

Explanation of features – Main Settings

Input Frequency

This setting indicates the frequency of the incoming stereo sync signal. Typically this should be a value higher than 100 Hz. On a PC based system, 60 Hz indicates improper graphics card setup. A value of “No Signal” indicates there is no input signal. In this case, check the connection between the control unit and your stereoscopic sync signal source. Also check your graphics card stereo sync setup. On NVIDIA Quadro cards a stereoscopic application must be running and visible in order for a sync signal to be generated. Digital Cinema (DCI) Projectors: The frequency will be 143 Hz or 144 Hz. Trouble Shooting: If the input frequency changes between values like 60 Hz to 120 Hz or 48 Hz to 144 Hz, this indicates stereo sync signal noise. Projector lamps are notorious for creating lots of noise. Be sure to use ferrite core noise suppressors on the input cable. These are included on all cables provided by Lightspeed Design.

Output Voltage

This setting indicates the current voltage of the modulator drive signal. It is factory set around 24V. The value will vary slightly since it is reporting the true measured output.

Trouble Shooting: If the voltage reads a substantially different value than 24V (12V for example) performance will be greatly reduced.

Signal Reversed

This setting establishes the eye coding or “invert state” for the control unit. Set to opposite state to invert the stereo. There are two options: Normal and Reverse.

Normal is equivalent to “L/R” (as seen on the control unit’s display). Yes is equivalent to “R/L”.

Digital Cinema (DCI) Projectors: DepthQ Modulator control unit setting should always be Normal.

Trouble Shooting: If there is excess crosstalk or the 3D image is reversed the above settings are incorrect.

Global Phase Shift

This setting establishes the delay value of the drive signal (expressed in microseconds). This setting is used to optimize the control unit’s synchronization with the projector’s dark time.

The default value is 0µs.

Page 33: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 31 Chapter 1: DepthQ® Polarization Modulator™

A value of 1500µs means the modulator will change orientation 1500 microseconds after the input signal changes its orientation.

The Global Phase shift setting is very important to the control unit’s perceived performance. Lightspeed generally calibrates this setting while monitoring the projector and signals on an oscilloscope. Please see below or contact Lightspeed for settings for each projector type and model.

Save Settings

When you have completed changes use “save settings”. All values will be permanently stored in the modulator EPROM and used upon power up.

Explanation of features – Advanced Settings

B-Delay

B-Delay is a factory set value and should always be set to 300. Do not change this value unless specifically instructed by Lightspeed Design. Incorrect settings can cause ghosting.

Min. 3D Input Frequency (introduced in firmware version 0.40)

Minimum 3D Input Frequency allows you to set the lower cut off for 3D operation. If the input signal frequency goes below the Minimum 3D Input Frequency, the control unit’s output will be disabled. The default value is 40Hz. When the output is disabled due to low input frequency, the text “L!” is shown on the screen.

Max. 3D Input Frequency (introduced in firmware version 0.40)

Maximum 3D Input Frequency allows you to set the upper cut off for 3D operation. If the input signal frequency goes above the Maximum 3D Input Frequency, the control unit’s output will be disabled. The default value is 500Hz. When the output is disabled due to high input frequency, the text “H!” is shown on the screen.

Description of Phantom Output

The Phantom Output feature allows the control unit to generate its own internal sync signal when it detects the outside stereo sync signal is absent. This can be useful when using a PC as it will allow the modulator to continue to show both left and right eyes after exiting the stereoscopic application. Without this feature one eye will be blacked out when you exit to the windows desktop. Special care must be taken when selecting the Phantom Frequency for single chip DLP projectors since it can interact with the projector in undesirable ways.

Page 34: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 32 Chapter 1: DepthQ® Polarization Modulator™

Phantom Output should typically be disabled in a cinema environment since you would normally want to be aware of a condition where the stereo sync signal is missing. It can be useful for forcing operation at a specific frequency. For example, if you are shooting colors using a 2D test pattern it may be desirable to force the control unit to operate at 144Hz instead of the 24Hz that the projector would be sending. To do this, unplug the BNC connector from the control unit, set your desired Phantom Frequency and then set Phantom System to “Enabled”. When you are done, be sure to set the Phantom System to “Disabled” and reconnect the BNC cable.

Phantom Output

This setting indicates the status of the phantom output system. “Active” indicates the outside stereo sync signal is absent and the Phantom System is currently in operation. “None” indicates the Phantom System is not in operation (either because Phantom Output is disabled or the outside stereo sync signal is present).

Phantom System

This setting indicates the operation mode of the Phantom System. “Disabled” indicates the Phantom System will not activate when the outside stereo sync signal is missing. “Enabled” indicates the Phantom System will activate when the outside stereo sync signal is missing.

Click the “Enable” or “Disable” buttons to enable or disable the Phantom System.

Phantom Frequency

This setting indicates the frequency at which the Phantom System will operate at. If you wish to change the frequency, type the new value in the box and click the “set” button.

A value of 144Hz tends to work well with DCI Cinema projection systems since it is an even multiple of 24fps. Special care must be taken when selecting the Phantom Frequency for single chip DLP projectors since it can interact with the projector in undesirable ways. You might need an especially high value to eliminate harmonics with the DLP light output.

Save Settings

When you have completed changes use “save settings”. All values will be permanently stored in the control unit EPROM and used upon power up.

Page 35: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 33 Chapter 1: DepthQ® Polarization Modulator™

Explanation of features – Advanced Settings

DHCP Settings (introduced in firmware version 0.40)

The control unit can have a static IP address or it can request an IP address from your network DHCP server. By default, the control unit has a static IP address of 192.168.1.254.

If you wish to switch to a DHCP assigned IP address, select the “DHCP Client” radio button and then click the “SAVE & NETWORK RESTART” button. This will reinitialize the network portion of the control unit (the main unit does not reboot). Upon start up, the control unit will request an IP address from your local DHCP server.

This IP address will be displayed on the bottom line of the LCD screen. This bottom line also cycles through the other network settings (netmask and port number). This IP address will be the address you need to type into your web browser to connect to the control unit. The computer you are using to connect to the control unit web interface must reside on the same network segment in order to communicate with the control unit. Most often this means the computer IP address should have the same first three numbers as the control unit, with only the last number being different. Note: If the control unit is not able to communicate with a DHCP server it will time out and configure a random static IP address in the 169.254.x.x address space. If you cannot resolve the issue with the DHCP server you may have to configure your computer with a static IP address that matches the first three numbers of the IP address the control unit is showing. The last number must be different from the last number of the IP address of the control unit.

Page 36: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 34 Chapter 1: DepthQ® Polarization Modulator™

IP Address

These fields both indicate and allow you to configure the IP address of the control unit. Normally it is set to 192-168-1-254. This is the IP address you should type into your web browser to connect to the control unit web interface.

Network Mask

Sometimes referred to as “Netmask”. These fields both indicate and allow you to configure the Network Mask of the control unit. Normally it is set it 255-255-255-0 unless your network requires a different value.

Communication Port

This field both indicates and allows you to configure the communication port that the control unit listens on. Normally it is set to 80 which is the standard for HTTP communication. Note: Be sure to click the “SAVE & NETWORK RESTART” button to apply all changes you have made on this screen. When you click this button, your values will be permanently stored in the control unit EPROM and the network interface will be re-initialized.

Page 37: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 35 Chapter 1: DepthQ® Polarization Modulator™

Recommended Settings for Projectors

Recommended settings for Digital Cinema projectors (April 2012):

Series 2 DCI Projectors

Set the Digital Cinema Projector 3D Controls Settings as follows, typical for Barco Series 2 (pictured below) and Christie CP2230 Series Multiplication 6:2

Activate 48 Hz

L/R Input Reference (NEC) = Use selected input port/polarity=true (see note below) (BARCO & Christie Series 2 = Use line interleave where first line=Left, second line=Right

Input Frame Dominance Right (R1L1 R2L2)*

L/R Display Reference Not Used

L/R Output Reference Polarity TRUE

Dark Time adjustment Setting 350 us

Output Reference Delay Time: 0 Phase: 0 Set the DepthQ Modulator Control Unit Settings as follows: Signal Reverse Normal

Global Phase Shift 0

Input frequency in Hz 144 Hz (Reflects signal coming in from projector) Drive voltage approximately 24v Trouble Shooting: If there is excess crosstalk the above settings are incorrect.

Trouble Shooting: If the voltage reads a substantially different value than 24V (12V for example) performance will be greatly reduced.

Note: The Input Frame Dominance setting is a function of the DCI Server. Depending of your configuration, you might find a setting of “Left (L1R1 L2R2)” will perform correctly.

Note: The correct "L/R input reference" setting is determined by the server and projector. If "Use line interleave where first line=Left, second line=Right" does not work, try "Use selected input port/polarity=true".

Page 38: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 36 Chapter 1: DepthQ® Polarization Modulator™

Series1 DCI Projectors

Set the Digital Cinema Projector 3D Controls Settings as follows, typical for Barco Series 1 (pictured below), NEC 1600C projector, and Christie projectors: Multiplication 6:2 Activate 48 Hz

L/R Input Reference (NEC) = Use selected input port/polarity=true (see note below) (BARCO & Christie Series 1) = Use active data port, Port A = Left, Port B = Right

Input Frame Dominance Right (R1L1 R2L2)*

L/R Display Reference Not Used

L/R Output Reference Polarity TRUE

Dark Time adjustment Setting 350 us

Output Reference Delay Time:0 Phase: 0 Set the DepthQ Modulator Control Unit Settings as follows: Signal Reverse Normal

Global Phase Shift 0

Input frequency 144 Hz (Reflects signal coming in from projector) Drive voltage approximately 24v Trouble Shooting: If there is excess crosstalk the above settings are incorrect.

Trouble Shooting: If the voltage reads a substantially different value than 24V (12V for example) performance will be greatly reduced.

Note: The correct "L/R input reference" setting is determined by the server and projector. If "Use line interleave where first line=Left, second line=Right" does not work, try "Use selected input port/polarity=true".

Page 39: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 37 Chapter 1: DepthQ® Polarization Modulator™

Series1 DCI Projectors – Alternative Setting

Series 1 DCI Alternative setting – If more delay is required (indicated by poor sync) Output Reference Delay Time: -1500 Phase: 0 Set the DepthQ Modulator Control Unit Settings as follows:

DepthQ Modulator Phase Shift 1500

Note: Make sure the projector Output Reference is negative 1500 (not positive 1500 or simply 1500)

Note: The Input Frame Dominance setting is a function of the DCI Server. Depending of your configuration, you might find a setting of “Left (L1R1 L2R2)” will perform correctly.

Note: The correct "L/R input reference" setting is determined by the server and projector. If "Use line interleave where first line=Left, second line=Right" does not work, try "Use selected input port/polarity=true".

Page 40: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 38 Chapter 1: DepthQ® Polarization Modulator™

Industrial Projectors

Recommended settings for Industrial Projectors (April 2012):

DepthQ HDs3D-1 3D projector, all 3D modes:

Control Unit: Signal Reverse Normal

Control Unit: Global Phase Shift 0 (zero)

Sharp PG-D45X3D:

Projector: Brilliant Color 0 (zero)

Projector: DLPLink Off

Control Unit: Signal Reverse Normal

Control Unit: Global Phase Shift 236

Sharp PG-D40W3D:

Projector: Brilliant Color 0 (zero)

Projector: DLPLink Off

Control Unit: Input Signal Reversed Normal

Control Unit: Global Phase Shift 303

Digital Projection, Inc M-VISION 3D:

Control Unit: Input Signal Reversed Normal

Control Unit: DepthQ Modulator Phase Shift 1000

Page 41: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 39 Chapter 1: DepthQ® Polarization Modulator™

ProjectionDesign F10 AS3D, with variable Dark Intervals:

IR Mode:

Projector: Stereo lock phase delay 0 (zero)

Control Unit: Input Signal Reversed Normal

Control Unit: DepthQ Modulator Phase Shift 6753

IR High Brightness

Projector: Stereo lock phase delay 0 (zero)

Control Unit: Input Signal Reversed Normal

Control Unit: DepthQ Modulator Phase Shift 0 (zero)

Christie Mirage HD18 Settings, dark interval variable

Projector: Dark Interval 980

Projector: Delay 770

Control Unit: Input Signal Reversed Normal

Control Unit: DepthQ Modulator Phase Shift 0 (zero)

Projector: Dark Interval 2022

Projector: Delay 670

Control Unit: Input Signal Reversed Normal

Control Unit: DepthQ Modulator Phase Shift 0 (zero)

Page 42: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 40 Chapter 1: DepthQ® Polarization Modulator™

Christie Mirage M Series Settings, dark interval variable

Projector: Dark Interval 1

Projector: Stereo Sync Delay 8.00

Control Unit: Input Signal Reversed Normal

Control Unit: DepthQ Modulator Phase Shift 0 (zero)

Projector: Dark Interval 2

Projector: Stereo Sync Delay 6.85

Control Unit: Input Signal Reversed Normal

Control Unit: DepthQ Modulator Phase Shift 0 (zero)

Page 43: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 41 Chapter 1: DepthQ® Polarization Modulator™

DepthQ® Technical Specifications

General Specifications

Operating Temperature Not to exceed 52° C Non-Condensing/Low Humidity Dimensions: Large (DCI) 22.8 x 16.5 cm (9” x 61/2”) Clear aperture 17.15 x 9.78 cm (6.75 x 3.85 in) Small 15.5 x 12.7 cm (6" x 5") Clear aperture 9.84 x 6.11 cm (3.875 x 2.41 in) Weight Estimate Large model 3.4 lbs Weight Estimate Small model 1.7 lbs Contrast/Ghost >100 : 1 in each eye Efficiency ~15% Screen Size Based on your projector brightness, from ~2-17.7 m (6-58 ft) Switching Time 50 μsec (symmetrical) Operating Temp +5 to 52 deg C (40 to 125 deg F) Actuator (Optional) Two-position relay closure for 2D to 3D switching Heat Protection Metallic Pre-Polarizer (integrated on Large model) Power: For DepthQ Modulator Electronics: Universal Power Supply

Input voltage 100-240Vac, 50/60Hz Output Power Rating: 15 W Output Voltage 12 Vdc Output Current 1.25 A Model PSAA15W-120-R For DepthQ Modulator Fan: Universal Power Supply

Input voltage 100-240Vac, 50/60Hz Output Power Rating: 15 W Output Voltage 12 Vdc Output Current 1.25 A Model PSAA15W-120-R For the moving actuator: Input voltage 100-240VAC, 50-60 Hz Input current 900mA Output voltage 29Vdc Output current 2A Model ZB-A290020-A

Page 44: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 42 Chapter 1: DepthQ® Polarization Modulator™

Drawings

LARGE MOUNT

Page 45: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 43 Chapter 1: DepthQ® Polarization Modulator™

Page 46: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 44 Chapter 1: DepthQ® Polarization Modulator™

Page 47: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 45 Chapter 1: DepthQ® Polarization Modulator™

Page 48: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 46 Chapter 1: DepthQ® Polarization Modulator™

Page 49: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 47 Chapter 1: DepthQ® Polarization Modulator™

Page 50: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 48 Chapter 1: DepthQ® Polarization Modulator™

Page 51: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 49 Chapter 1: DepthQ® Polarization Modulator™

Page 52: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 50 Chapter 1: DepthQ® Polarization Modulator™

Page 53: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 51 Chapter 1: DepthQ® Polarization Modulator™

Page 54: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 52 Chapter 1: DepthQ® Polarization Modulator™

Page 55: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 53 Chapter 1: DepthQ® Polarization Modulator™

Page 56: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 54 Chapter 1: DepthQ® Polarization Modulator™

Page 57: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 55 Chapter 1: DepthQ® Polarization Modulator™

Page 58: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 56 Chapter 1: DepthQ® Polarization Modulator™

Drawings

SMALL MOUNT

Page 59: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 57 Chapter 1: DepthQ® Polarization Modulator™

Page 60: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 58 Chapter 1: DepthQ® Polarization Modulator™

Page 61: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 59 Chapter 1: DepthQ® Polarization Modulator™

Page 62: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 60 Chapter 1: DepthQ® Polarization Modulator™

DepthQ® Timing Process

General Overview

The following is an overview of tools and process to set the polarization modulator timing relative to a projector's dark interval.

032-Scope & Photo sensor Connections Overview

033-Ocilliscope Connections

A) Connection to modulator drive signal

B) Connection to Photo sensor

Page 63: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 61 Chapter 1: DepthQ® Polarization Modulator™

034-Ocilliscope Connections Shows the modulator drive signal “Y” To test leads for connection to Oscilloscope.

035a-Photo Sensor & Modulator Front Light from projector passes through modulator and strikes the Photo sensor. Photo sensor is connected to oscilloscope.

035b-Photo Sensor & Modulator Back Light from projector passes through modulator and strikes the Photo sensor. Photo sensor is connected to oscilloscope.

Page 64: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 62 Chapter 1: DepthQ® Polarization Modulator™

036-Photo Sensor Connections Overview from front.

037-Control Unit Settings.

Page 65: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 63 Chapter 1: DepthQ® Polarization Modulator™

Oscilloscope Measurements

The images below show the relationship between a single frame of displayed video and the modulator drive signal. The blue line shows the light from the projector as measured by the photo sensor. The brown line (towards the bottom) shows the modulator drive voltage.

The area between the dotted vertical lines marks the projector’s dark interval. In this example it is 1 millisecond in duration.

Correct position of delay Notice how the drive voltage changes states 10μs after the beginning of the dark interval.

Incorrect position of delay Notice how the drive voltage changes states approximately 1000μs before the dark interval. The user must adjust the modulator driver phase shift value until the brown line is in the correct position (just after the beginning of the dark interval)

Page 66: DepthQ Polarization Modulator Reference Manual 2012- V2-0-6

Page | 64 DepthQ® Warrantee

DepthQ® Warranty

Warranty

Lightspeed Design, Inc. warrants the equipment it manufactures to be free from defects in material and workmanship.

The Period of Warranty is (i) three (3) years from the date of installation, or (ii) thirty eight (38) months from the date of shipment by Lightspeed Design, Inc. of a product covered hereby, whichever time period elapses first.

If equipment fails because of such defects and Lightspeed Design, Inc. is notified within allotted time period from the date of shipment, Lightspeed Design, Inc. will, at its option, repair or replace the equipment, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifications. Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair. Such repairs are warrantied for ninety (90) days from the day of reshipment to the Buyer.

This warranty is in lieu of all other warranties expressed or implied, including without limitation, any implied warranty or merchantability or fitness for any particular purpose, all of which are expressly disclaimed.

1. Proof of sale may be required in order to claim warranty.

2. Customers outside the US are responsible for shipping charges to and from Lightspeed Design, Inc.

The information in this manual has been carefully checked and is believed to be accurate. However, Lightspeed Design, Inc. assumes no responsibility for any inaccuracies that may be contained in this manual. In no event will Lightspeed Design, Inc. be liable for direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. The technical information contained herein regarding the features and specifications is subject to change without notice.