Upload
vuongnga
View
257
Download
11
Embed Size (px)
Citation preview
BROOK-MTL, 63 Allens Road, East Tamaki, Auckland, New Zealand Tel +64 9 271 6063 - Fax +64 9 271 6020 - www.brookmtl.co.nz - [email protected]
Associate company: Rotating Machinery Supplies, 6 Devon Road, Hamilton [email protected]
Delta VFD-EL AC Drives Mini
FEATURES The VFD-EL series is multiple function new generation micro type AC drive. It has built in EMI filter, RFI switch, easy DC bus sharing for side-by-side installation, high precision current detection, overload protection, and a built in keypad. SPECIFICATIONS Output frequency: 0.1 ~ 600Hz 3 points adjustable V/f curve Built-in PID feedback control RFI-switch for IT mains Built-in EMI filter (for models 230V 1-phase and 460V 3-phase) Use RS-485 communication interface (RJ-45) with Modbus protocol Optional communication modules for multiple communication protocols, such as Profibus,
DeviceNet, LonWorks and CANopen Complete protection function
APPLICATIONS Small size pump & fan, blowing machine, conveyer belt, simple DIY processing equipment.
Part Numbers:
SKU KW HP Volts Phase Amps
VDEL04 3/3 MINI 0.4 1/2 460 3 1.5
VDEL07 3/3 MINI .75 1 460 3 2.5
VDEL1.5 3/3 MINI 1.5 2 460 3 4.2
VDEL2.2 3./3 MINI 2.2 3 460 3 5.5
VDEL4.0 3/3 MINI 4 5 460 3 8.2
VDEL0.4 1/3 MINI 0.4 1/2 230 1 2.5
VDEL0.7 1/3 MINI 0.7 1 230 1 4.2
VDEL1.5 1/3 MINI 1.5 2 230 1 7.5
VDEL2.2 1/3 MINI 2.2 3 230 1 11
VFD-EL AC DRIVES MINI CATALOGUE
BROOK-MTL, 63 Allens Road, East Tamaki, Auckland, New Zealand
Tel +64 9 271 6063 - Fax +64 9 271 6020 - www.brookmtl.co.nz - [email protected]
Associate companies: Rotating Machinery Supplies, 6 Devon Road, Hamilton [email protected] SOCO ELECTRIC MOTORS, 473 Tremaine ave, Palmerston North [email protected]
All data is subject to confirmation by BROOK-MTL EL MINI 1/3
QUICK SET UP INSTRUCTIONS FOR DELTA VDF-EL MINI
3PHASE TO 3PHASE VARIABLE SPEED DRIVE
Important Notice
Wiring and connection must be carried out by a registered electrician.
Connection by an unqualified person voids the warranty.
Please check the suitability of the motor before attempting to connect it to the device.
Ensure the motor terminals are connected for 400V supply.
Operations panel
Quick Setup for Variable Speed Drive
Turn on power to unit and follow as below:
F60.0 will be displayed on the screen.
Press the enter button.
00. will appear on the screen.
Press enter again.
00.00 will appear on the screen.
Use the up and down keys to change parameters selections to the desired one. Press enter
You will now be able to change the parameter to the desired value or setting. Press enter. End will flash on your screen to indicate that your setting has been saved.
Continue the above steps till all of your parameters have been set.
Once all the parameters have been set press the Mode button till the F60.0 screen comes up again.
BROOK-MTL, 63 Allens Road, East Tamaki, Auckland, New Zealand
Tel +64 9 271 6063 - Fax +64 9 271 6020 - www.brookmtl.co.nz - [email protected]
Associate companies: Rotating Machinery Supplies, 6 Devon Road, Hamilton [email protected] SOCO ELECTRIC MOTORS, 473 Tremaine ave, Palmerston North [email protected]
All data is subject to confirmation by BROOK-MTL EL MINI 1/3
List of quick set parameters
01.00 Change to the maximum Frequency required.
01.01 Change value to match 01.00
01.02 Change to 400V (Max Voltage output)
01.03 Mid-Point Frequency. Set to half the value of 01.00
01.04 Mid-point Voltage. Set to half the value of 01.02
01.07 Upper limit Frequency, this setting is a percentage value of 01.00
01.08 Lower limit Frequency, this setting is a percentage value of 01.00
01.09 Acceleration time
01.10 Deceleration time
02.00 Source of master Frequency Command. Set to 4 for keypad potentiometer. Factory setting is up and
down buttons for speed control.
07.00 Motor rated current. Set to a percentage of the full load amps.
FOR ADVANCED SET UP REFER TO MANUAL AND CD ROM PROVIDED
OP
TIO
NA
L IF
REQ
UIR
ED
Connect Live to R, Neutral to S
And the Motor to U,V,W
Instructions for Remote Setup
(Remote On Off/ Speed Variation)
For remote stop and start connect
between DCM and MI1. (DCM is
your common)
For remote Potentiometer
connect the pot to +10V, AVI and
ACM (common).
Set 02.00 to 1
Set 02.01 to 1
Set 04.04 to 0
BROOK-MTL, 63 Allens Road, East Tamaki, Auckland, New Zealand
Tel +64 9 271 6063 - Fax +64 9 271 6020 - www.brookmtl.co.nz - [email protected]
Associate companies: Rotating Machinery Supplies, 6 Devon Road, Hamilton [email protected] SOCO ELECTRIC MOTORS, 473 Tremaine ave, Palmerston North [email protected]
All data is subject to confirmation by BROOK-MTL EL MINI 1/3
QUICK SET UP INSTRUCTIONS FOR DELTA VDF-EL MINI
1PHASE TO 3PHASE VARIABLE SPEED DRIVE
Important Notice
Wiring and connection must be carried out by a registered electrician.
Connection by an unqualified person voids the warranty.
Please check the suitability of the motor before attempting to connect it to the device.
Ensure the motor terminals are connected in a DELTA connection.
Operations panel
Quick Setup for Variable Speed Drive
Turn on power to unit and follow as below:
F60.0 will be displayed on the screen.
Press the enter button.
00. will appear on the screen.
Press enter again.
00.00 will appear on the screen.
Use the up and down keys to change parameters selections to the desired one. Press enter
You will now be able to change the parameter to the desired value or setting. Press enter. End will flash on your screen to indicate that your setting has been saved.
Continue the above steps till all of your parameters have been set.
BROOK-MTL, 63 Allens Road, East Tamaki, Auckland, New Zealand
Tel +64 9 271 6063 - Fax +64 9 271 6020 - www.brookmtl.co.nz - [email protected]
Associate companies: Rotating Machinery Supplies, 6 Devon Road, Hamilton [email protected] SOCO ELECTRIC MOTORS, 473 Tremaine ave, Palmerston North [email protected]
All data is subject to confirmation by BROOK-MTL EL MINI 1/3
List of quick set parameters
01.00 Change to the maximum Frequency required.
01.01 Change value to match 01.00
01.02 Change to 230V (Max Voltage output)
01.03 Mid-Point Frequency. Set to half the value of 01.00
01.04 Mid-point Voltage. Set to half the value of 01.02
01.07 Upper limit Frequency, this setting is a percentage value of 01.00
01.08 Lower limit Frequency, this setting is a percentage value of 01.00
01.09 Acceleration time
01.10 Deceleration time
02.00 Source of master Frequency Command. Set to 4 for keypad potentiometer. Factory setting is up and
down buttons for speed control.
07.00 Motor rated current. Set to a percentage of the full load amps.
FOR ADVANCED SET UP REFER TO MANUAL AND CD ROM PROVIDED
OP
TIO
NA
L IF
REQ
UIR
ED
Connect Live to R, Neutral to S
And the Motor to U,V,W
Instructions for Remote Setup
(Remote On Off/ Speed Variation)
For remote stop and start connect
between DCM and MI1. (DCM is
your common)
For remote Potentiometer con-
nect the pot to +10V, AVI and
ACM (common).
Set 02.00 to 1
Set 02.01 to 1
Set 04.04 to 0