6
AFE2000_C_TC_20120217 AFE2000 www.delta.com.tw/ia IABU Headquarters Asia Americas Europe Delta Electronics, Inc. No.18, Xinglong Rd., Taoyuan City, TEL: 886-3-362-6301 / FAX: 886-3-371-6301 Delta Electronics (Jiangsu) Ltd. Wujiang Plant 3 1688 Jiangxing East Road, Wujiang Economic Development Zone Wujiang City, Jiang Su Province, People's Republic of China (Post code: 215200) TEL: 86-512-6340-3008 / FAX: 86-769-6340-7290 Delta Greentech (China) Co., Ltd. 238 Min-Xia Road, Post code : 201209 TEL: 86-21-58635678 / FAX: 86-21-58630003 Delta Electronics (Japan), Inc. Tokyo Office 2-1-14 Minato-ku Shibadaimon, Tokyo 105-0012, Japan TEL: 81-3-5733-1111 / FAX: 81-3-5733-1211 Delta Electronics (Korea), Inc. TEL: 82-2-515-5303 / FAX: 82-2-515-5302 Delta Electronics Int’l (S) Pte Ltd 4 Kaki Bukit Ave 1, #05-05, Singapore 417939 TEL: 65-6747-5155 / FAX: 65-6744-9228 Delta Electronics (India) Pvt. Ltd. Delta Products Corporation (USA) Raleigh Office P.O. Box 12173,5101 Davis Drive, Research Triangle Park, NC 27709, U.S.A. TEL: 1-919-767-3800 / FAX: 1-919-767-8080 Delta Greentech (Brasil) S.A Sao Paulo Office Rua Itapeva, 26 - 3° andar Edificio Itapeva One-Bela Vista 01332-000- -SP-Brazil TEL: +55 11 3568-3855 / FAX: +55 11 3568-3865 Deltronics (The Netherlands) B.V. Eindhoven Office De Witbogt 15, 5652 AG Eindhoven, The Netherlands TEL: 31-40-2592850 / FAX: 31-40-2592851 We reserve the right to change the information in this catalogue without prior notice. Taoyuan Technology Center Taoyuan County 33068, Taiwan Pudong District, ShangHai, P.R.C. 1511, Byucksan Digital Valley 6-cha, Gasan-dong, Geumcheon-gu, Seoul, Korea, 153-704 Plot No 43 Sector 35, HSIIDC Gurgaon, PIN 122001, Haryana, India TEL : 91-124-4874900 / FAX : 91-124-4874945 S ão Paulo * Delta Active Front End Automation for a Changing World

Delta Active Front End AFE2000 - Softstart UK · 2013. 8. 18. · Clear energy savings: more than 95% of the energy is regenerated and supplied ... clean and efficient energy solutions

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Delta Active Front End AFE2000 - Softstart UK · 2013. 8. 18. · Clear energy savings: more than 95% of the energy is regenerated and supplied ... clean and efficient energy solutions

AFE2000_C_TC_20120217

AFE2000

www.delta.com.tw/ia

IABU Headquarters

Asia

Americas

Europe

Delta Electronics, Inc.

No.18, Xinglong Rd., Taoyuan City,

TEL: 886-3-362-6301 / FAX: 886-3-371-6301

Delta Electronics (Jiangsu) Ltd.Wujiang Plant 31688 Jiangxing East Road, Wujiang Economic Development ZoneWujiang City, Jiang Su Province, People's Republic of China (Post code: 215200)TEL: 86-512-6340-3008 / FAX: 86-769-6340-7290

Delta Greentech (China) Co., Ltd.238 Min-Xia Road,

Post code : 201209TEL: 86-21-58635678 / FAX: 86-21-58630003 Delta Electronics (Japan), Inc.Tokyo Office 2-1-14 Minato-ku Shibadaimon, Tokyo 105-0012, JapanTEL: 81-3-5733-1111 / FAX: 81-3-5733-1211

Delta Electronics (Korea), Inc.

TEL: 82-2-515-5303 / FAX: 82-2-515-5302

Delta Electronics Int’l (S) Pte Ltd4 Kaki Bukit Ave 1, #05-05, Singapore 417939TEL: 65-6747-5155 / FAX: 65-6744-9228

Delta Electronics (India) Pvt. Ltd.

Delta Products Corporation (USA)Raleigh OfficeP.O. Box 12173,5101 Davis Drive, Research Triangle Park, NC 27709, U.S.A.TEL: 1-919-767-3800 / FAX: 1-919-767-8080

Delta Greentech (Brasil) S.ASao Paulo OfficeRua Itapeva, 26 - 3° andar Edificio Itapeva One-Bela Vista01332-000- -SP-BrazilTEL: +55 11 3568-3855 / FAX: +55 11 3568-3865

Deltronics (The Netherlands) B.V.Eindhoven OfficeDe Witbogt 15, 5652 AG Eindhoven, The Netherlands TEL: 31-40-2592850 / FAX: 31-40-2592851

We reserve the right to change the information in this catalogue without prior notice.

Taoyuan Technology Center

Taoyuan County 33068, Taiwan

Pudong District, ShangHai, P.R.C.

1511, Byucksan Digital Valley 6-cha, Gasan-dong, Geumcheon-gu, Seoul, Korea, 153-704

Plot No 43 Sector 35, HSIIDC Gurgaon, PIN 122001, Haryana, India TEL : 91-124-4874900 / FAX : 91-124-4874945

São Paulo

*

Delta Active Front End

Automation for a Changing World

Page 2: Delta Active Front End AFE2000 - Softstart UK · 2013. 8. 18. · Clear energy savings: more than 95% of the energy is regenerated and supplied ... clean and efficient energy solutions

1 2

Clear energy savings: more than 95% of the energy is regenerated and supplied back to the mains.

Full-load operation: input-side current THD lower than 4% and power factor up to 99%.

AC motor drives with AFE2000: supports 4-quadrant operation with variable frequencies and adjustable system.

Constant DC bus voltage: unaffected by mains voltage fluctuations.

Large-inertia loads, such as centrifuge equipment, dewatering machines and roving machines.

Quick braking, such as machine tools, bag making machines, auto storage and retrieval systems, and lathes

Long-term energy feedback, such as wind power, water power, steel printing and paper making machinery (winding equipment).

Improves power quality for industries such as semiconductor and panel industries

When a crane is unloading large goods or cargos, its motor is in generator mode and produces excess energy. AFE2000 can be installed as a replacement for the traditional brake resistor.

FeaturesReplaces traditional brake resistor to reduce heat energy.

Applications

4-quadrant loads including elevators, cranes and pumpjacks (oil extraction machines)

When an elevator is traveling upward with a light load or downward with a heavy load, its motor is in generator mode and produces excess energy. AFE2000 can be installed to convert excess energy into reusable electricity for other devices and equipment used.

‧IEEE519-1992‧IEC/EN61000-3-12‧IEC/EN61000-3-4‧IEC/EN61000-3-2

Replace traditional brake resistors with the AFE2000 to convert regenerative energy (excess heat) into reusable electricity.

Regenerative energy = excess heatRegenerative energy = reusable electricity

Lights

Air Conditioners

AC Motor DriveMains

powerReactor

Drive

Regenerative energy

AFE2000

Reduces Harmonics Improves Power Factor Power Regeneration

Before using

AFE2000After using

AFE2000

Phase voltage

Input current

Input current distortion 80% Input current distortion 5%

Phase voltage

Input current

Traditional Brake Resistor

Dissipate the regnerative energy as heat

Braking Unit

Drive

Regenerative energy

Mains power

Improves power factor and decreases harmonic distortion.

THD<=5%, power factor > 99%

Regenerative energy

Power Consumed

Traditional AC motor drive

60%

THD (%)

AFE 2000

5%

Decreases harmonic distortion 55%

Improves power factor 20%

80%99%

Power Foctor (%)

AFE 2000Traditional AC motor drive

Improve power factor, lower harmonic distortion, and decrease energy consumption to reduce energy costs and protect the environment.

The AFE2000 is your best choice for the following international standards:

motor motor

Page 3: Delta Active Front End AFE2000 - Softstart UK · 2013. 8. 18. · Clear energy savings: more than 95% of the energy is regenerated and supplied ... clean and efficient energy solutions

DeviceNet EtherNet/IP

MODBUS TCP (DS301)

075

7.5

35

150

15

70

220

22

95

370

37

150

150% 60Sec

±5%

IP20/NEMA1

-10 +50℃~ ℃

-25 +65℃~

230V

170~ 250Vac

300~370Vdc

075

7.5

20

150

15

35

220

22

50

370

37

75

450

45

95

750

75

160

150% 60Sec

±5%

IP20/NEMA1

-10 +50℃~ ℃

-25 +65℃~

460V

325~ 500Vac

600~740Vdc

Multiple SolutionsThe AFE2000 provides multiple solutions for regenerative energy, offering better power quality while reducing total electricity costs.It achieves Delta's mission “to provide innovative, clean and efficient energy solutions for a better tomorrow”.

This figure is for demonstration purposes only, please refer to

standard wiring diagrams for wiring details.

High-speed Fieldbus

Advanced network functionsProvides various communication network cards and fieldbus cards

Built-in RS-485 modbus protocol

Specifications

Model AFE-_ _ _A23A

Applicable power (kW)

Rated input voltage (V)

Rated input current (A)

Voltage control

Overload capacity

Frequency tolerance

Power factor at input side

Harmonic (%)

Cooling method

Installation environment

Ambient temperature

Storage/transportation temperature

Ambient humidity

Vibration

0.95 to above 0.99

0.95 to above 0.99

Less than 5% (at rated current)

Less than 5% (at rated current)

Fan cooling

Fan cooling

For indoors and altitudes of 0~1000m (3280.60 feet), keep away from direct sunlight, corrosive gases, liquids and dust. For altitudes above 1000m (3280.60 feet), please decrease 3% of rated

current for every 500m (1640.40 feet) increase. The maximum altitude is 2500m (8202.00 ft)

Lower than 90%RH (non-condensing)25.9m/ S (0.6G) less than 10~55Hz (JIS C0040)

Model AFE-_ _ _A43A

Applicable power (kW)

Rated input voltage (V)

Rated input current (A)

Voltage control

Overload capacity

Frequency tolerance

Power factor at input side

Harmonic (%)

Cooling method

Installation environment

Ambient temperature

Storage/transportation temperature

Ambient humidity

Vibration

Lower than 90%RH (non-condensing)25.9m/ S (0.6G) less than 10~55Hz (JIS C0040)

For indoors and altitudes of 0~1000m (3280.60 feet), keep away from direct sunlight, corrosive gases, liquids and dust. For altitudes above 1000m (3280.60 feet), please decrease 3% of rated current for every 500m (1640.40 feet) increase.

The maximum altitude is 2500m (8202.00 ft)

Enclosure type

Enclosure type

3 4

U

VW

U

VW

U

VW

RST

+_

+_

+_

+_

AC/DC

ReactorMotor

Motor

Motor

AFE2000 C2000

C2000

RST

+

AC/DC

U

VW__

+

ReactorMotor

AFE2000

C2000

Page 4: Delta Active Front End AFE2000 - Softstart UK · 2013. 8. 18. · Clear energy savings: more than 95% of the energy is regenerated and supplied ... clean and efficient energy solutions

Standard WiringOne-to-One Installation (One AFE unit + One AC motor drive)

*1 The Delta AC reactor (optional accessory) comes with a thermal protection function. When the reactor's temperature exceeds 120 , the TH3 terminal will come ON and the AFE 2000 will receive a signal from the MI terminal to issue a warning message.

*2 For one-to-many installation, installing a fuse on the AC motor drive's input side is recommended. Please select a compatible fuse for your AC motor drive using the equation:: Fuse specification= AC rated input current/ 0.78x1.5

*3 If the AC reactor installed on the system is not Delta's AC reactor, please connect the reactor's terminal to the power input terminal (R/L1, S/L2, T/L3) for wiring.

One-to-Many Installation (One AFE unit + Many AC motor drives)

*1 The Delta AC reactor (optional accessory) comes with a thermal protection function. When the reactor's temperature exceeds 120 , the TH3 terminal will come ON and the AFE 2000 will receive a signal from the MI terminal to issue a warning message.

*2 For one-to-many installation, installing a fuse on the AC motor drive's input side is recommended. Please select a compatible fuse for your AC motor drive using the equation:: Fuse specification= AC rated input current/ 0.78x1.5

*3 If the AC reactor installed on the system is not Delta's AC reactor, please connect the reactor's terminal to the power input terminal (R/L1, S/L2, T/L3) for wiring.

AC Reactor (Standard)

Delta AFE 2000

Option Solt 1

I/O Extension Card8 1

SG+

SG-

MO2

MCM

MO1

R/L1

S/L2

T/L3

Mi1

MI3

MI4

MI5

MI6

Run

System error

Reset after fault

Reactor over heat

MI7

Digital signal commonDCM

MI2Stop

MI8

COM

8 1

+24V

r1/l1

s1/l2

t1/l3

Multi-function 6

Multi-function 7

Multi-function 8

Multi-funtion output 3

Multi-funtion output 4

RA 1

RB 1

RC 1

Indication:

DC Bus level attainedMulti-funtion output 1

Power removal safety functionfor EN954-1 and IEC/EN61508

DCM

S1

Digital singal common

X

Y

Z

Main circuit terminal Control circuit terminal Shielded leads & Cable

Th3

Th3

*3

RA 2

RB 2

RC 2

Indication:

AFE2000 is readyMulti-funtion output 2

Mains Input

Frequency U

V

W

*1

s1t1 r1

DC+

DC-

+1/DC+

-/DC-

Motor

IM/PM

AC Motor Drive

*2

Optional

AC Reactor (Standard)

Delta AFE 2000

Option Solt 1

I/O Extension Card8 1

SG+

SG-

MO2

MCM

MO1

R/L1

S/L2

T/L3

Mi1

MI3

MI4

MI5

MI6

Run

System error

Reset after fault

Reactor over heat

MI7

Digital signal commonDCM

MI2Stop

MI8

COM

8 1

+24V

r1/l1

s1/l2

t1/l3

Multi-function 6

Multi-function 7

Multi-function 8

Multi-funtion output 3

Multi-funtion output 4

RA 1

RB 1

RC 1

Indication:

DC Bus level attainedMulti-funtion output 1

Power removal safety functionfor EN954-1 and IEC/EN61508

DCM

S1

Digital singal common

X

Y

Z

Main circuit terminal Control circuit terminal Shielded leads & Cable

Th3

Th3

*3

RA 2

RB 2

RC 2

Indication:

AFE2000 is readyMulti-funtion output 2

Mains Input

Frequency U

V

W

*1

s1t1 r1

+1/DC+

-/DC-

Motor

IM/PM

(1) AC Motor Drive

(2) AC Motor Drive

*2

DC+

DC-

+1/DC+

-/DC-

Motor

IM/PM

Optional

Optional

5 6

Page 5: Delta Active Front End AFE2000 - Softstart UK · 2013. 8. 18. · Clear energy savings: more than 95% of the energy is regenerated and supplied ... clean and efficient energy solutions

mm

W W1H H1D D1*

190.0

7.48

173.0

6.81

320.0

12.60

303.0

11.93

190.0

7.48

22.2

0.87

43.8

1.72

Φ1 2Φ 3Φ

inch

77.9

3.07

34.0

1.34B1

S1 S2

8.5 8.5

0.33 0.33

D1*:Flange mounting

MODELAFE075A23AAFE075A43AAFE150A43A

mm

W W1 S1 S2H H1D D1*

250.0

9.84

231.0

9.09

400.0

15.75

381.0

15.00

210.0

8.27

22.2

0.87

50.0

1.97

Φ1 2Φ 3Φ

inch

92.9

3.66

34.0

1.34C1

8.5 8.5

0.33 0.33

MODELAFE150A23AAFE220A23AAFE220A43A

WW1 D

H2

D1

WW1

H

S1 S2

H1

MODEL

AFE370A43AAFE450A43AAFE750A43A

AFE370A23A

mm

W W1H H1D D1*

inchB1

S1 S2H2

330.0

12.99

550.0 285.0

11.2221.65

525.0

20.67

11.0 11.0

0.43 0.43

107.2

4.22

275.0

10.83

492.0

19.37

【Version Type】

A:Standard

【Applicable power range 】

【 】Model Name

6:696V; 4:460V; 2:230V

【Input Voltage】

【District 】

AFE 075 A 4 3 A

075

110:11kW

150:15kW

:7.5kW 185:18.5kW

220:22kW

300:30kW

450:45kW

550:55kW

750:75kW

A: ; All C:China; U:US; E:Europe

3-phase

【Input Voltage】

【Applicable Power in kW】

【Type】

【Accessories】

AF - RC 075 A 4

075

110:11kW

150:15kW

185:18.5kW

220:22kW

:7.5kW 300:30kW

450:45kW

550:55kW

750:75kW

A:Standard; H:Advance

6:696V; 4:460V; 2:230V

AFE2000AFE2000

Dimensions

Frame B

Frame D

Frame C

Frame

Frame

Frame

D1*:Flange mounting

D1*:Flange mounting

Model Name

ReactorReactor

Active Front End

【 】Model NameActive Front End

Reactor

7 8

Page 6: Delta Active Front End AFE2000 - Softstart UK · 2013. 8. 18. · Clear energy savings: more than 95% of the energy is regenerated and supplied ... clean and efficient energy solutions

kW

7.5

15

22

37

Frame

B

C

D

075

150

220

370

AF-RC075A2

AF-RC150A2

AF-RC220A2

AF-RC370A2

Inductance (mH)

Inductance (mH)

2.1

1.05

0.77

0.5

35

70

95

150

kW

7.5

15

22

Frame

AF-RC075A4

AF-RC150A4

AF-RC220A4

AF-RC370A4

B

C

075

150

220

37

45

75

D

370

450

750

AF-RC450A4

AF-RC750A4

7.32

4.18

2.92

1.96

1.54

0.92

20

35

50

75

95

160

230V

460V

B MAX

E

A MAX

CM

AX

G

H

D

4-F: Mounting holes

2-I: Eyebolts

Unit : mm(inch)

355

355

385

385

420

305

AF-RC150A4

AF-RC220A4

AF-RC370A4

AF-RC450A4

AF-RC750A4

AF-RC075A4

180

200

210

230

240

159

328

328

385

385

440

280

200

200

200

200

250

150

139

159

168

188

200

125

M10

M10

M12

M12

M12

M10

11

11

13

13

13

11

26

26

25

25

25

22

M10

M10

M10

M10

M12

M10

52

62

87

105

137

28

305

355

355

385

AF-RC075A2

AF-RC150A2

AF-RC220A2

AF-RC370A2

159

180

200

210

280

328

328

385

150

200

200

200

125

139

159

168

M10

M10

M10

M12

11

11

11

13

22

26

26

25

M10

M10

M10

M10

28

52

62

87

A B C D E F G H Ikg

Approx. Mass

R(L1)

S(L2)

T(L3)

r1/l1

s1/l2

t1/l3

X

Y

Z

U

V

W

TH3

*1

TH3

MI5

*2

U X V Y ZW

r1s1t1

DCM

Standard Reactors

Standard Reactor Diagram

*1 The Delta AC reactor (optional accessory) comes with a thermal protection function. When the reactor's temperature exceeds 120 , the TH3 terminal will come ON and the AFE 2000 will receive a signal from the MI terminal to issue a warning message. *2 If the AC reactor installed on the system is not Delta's AC reactor, please connect the reactor's terminal to the power input terminal (R/L1, S/L2, T/L3) for wiring.

Mains Input

Frequency

AFE-_ _ _A43A

Applicable Model

AFE-_ _ _A23A

Applicable ModelReactor Model

Reactor Model

(Arms)

Rated Curreut

(Arms)

Rated Curreut

Model

Standard Reactor

Delta AC Motor Drives for AFE2000

VFD-VL

VFD-VE

VFD-VJ

ELVFD-

VFD-F

Delta Motor Drive

Delta Servo Drive: ASDA-A+, ASDA-A2, ASDA-B2

230V 440V

5.5kW~22kW5.5kW~22kW

3.7kW~22kW

0.75kW~22kW

0.75kW~22kW

5.5kW~22kW5.5kW~22kW

3.7kW~22kW

0.75kW~30kW

0.75kW~22kW

BVFD-

C2000 C2000

EVFD-

VFD-VE

VFD-F

BVFD-

VFD-VLVFD-VJ

ELVFD-

EVFD-