169
Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

  • Upload
    lamtu

  • View
    223

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Dell Chassis Management Controller Version 6.10 for PowerEdge M1000eRACADM CLI Guide

Page 2: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Notes, cautions, and warnings

NOTE: A NOTE indicates important information that helps you make better use of your product.

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

© January 2008 - June 2018 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.

2018 - 06

Rev. A01

Page 3: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Contents

1 Introduction....................................................................................................................................................7New in this release............................................................................................................................................................. 7Supported RACADM Interfaces....................................................................................................................................... 7RACADM Syntax Usage.................................................................................................................................................... 8

SSH, Telnet, or Remote RACADM............................................................................................................................. 8SSH or Telnet RACADM..............................................................................................................................................8Remote RACADM........................................................................................................................................................ 8RACADM Command Options..................................................................................................................................... 9

Supported RACADM Subcommands...............................................................................................................................9Other Documents You May Need....................................................................................................................................11Accessing documents from the Dell EMC support site............................................................................................... 12Contacting Dell..................................................................................................................................................................12

2 RACADM Subcommand Details.................................................................................................................... 13Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands...........................14Racadm help and help with subcommand.....................................................................................................................15Help and help subcommand............................................................................................................................................ 17arp.......................................................................................................................................................................................17chassisaction..................................................................................................................................................................... 18chassislog...........................................................................................................................................................................19closessn............................................................................................................................................................................. 19clrraclog.............................................................................................................................................................................20clrsel...................................................................................................................................................................................20cmcchangeover................................................................................................................................................................20config..................................................................................................................................................................................21connect............................................................................................................................................................................. 22deploy................................................................................................................................................................................ 22eventfilters........................................................................................................................................................................ 24feature............................................................................................................................................................................... 25featurecard........................................................................................................................................................................26fwupdate........................................................................................................................................................................... 27get......................................................................................................................................................................................30getactiveerrors.................................................................................................................................................................. 31getarraycfg........................................................................................................................................................................33getassettag....................................................................................................................................................................... 33getchassisname................................................................................................................................................................34getconfig........................................................................................................................................................................... 34getdcinfo........................................................................................................................................................................... 36getflexaddr........................................................................................................................................................................38getfanreqinfo.................................................................................................................................................................... 39getioinfo............................................................................................................................................................................. 41getkvminfo........................................................................................................................................................................ 43getled.................................................................................................................................................................................43

Contents 3

Page 4: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

getmacaddress.................................................................................................................................................................44getmodinfo........................................................................................................................................................................48getniccfg...........................................................................................................................................................................50getpbinfo...........................................................................................................................................................................52getpminfo..........................................................................................................................................................................53getraclog........................................................................................................................................................................... 55getractime.........................................................................................................................................................................56getredundancymode........................................................................................................................................................56getsel.................................................................................................................................................................................56getsensorinfo.................................................................................................................................................................... 57getslotname......................................................................................................................................................................59getssninfo......................................................................................................................................................................... 60getsvctag...........................................................................................................................................................................61getsysinfo...........................................................................................................................................................................61gettracelog........................................................................................................................................................................62getversion......................................................................................................................................................................... 63ifconfig.............................................................................................................................................................................. 65krbkeytabupload...............................................................................................................................................................65netstat...............................................................................................................................................................................65ping.................................................................................................................................................................................... 66ping6..................................................................................................................................................................................66racdump............................................................................................................................................................................ 67racreset............................................................................................................................................................................. 69racresetcfg........................................................................................................................................................................69remoteimage..................................................................................................................................................................... 70set....................................................................................................................................................................................... 71serveraction...................................................................................................................................................................... 72setarraycfg........................................................................................................................................................................ 73setassettag........................................................................................................................................................................74setchassisname................................................................................................................................................................ 75setflexaddr........................................................................................................................................................................ 75setled................................................................................................................................................................................. 76setniccfg............................................................................................................................................................................76setractime......................................................................................................................................................................... 78setslotname.......................................................................................................................................................................79setsysinfo.......................................................................................................................................................................... 79sshpkauth..........................................................................................................................................................................80sslcertdownload................................................................................................................................................................ 81sslcertupload..................................................................................................................................................................... 81sslcertview........................................................................................................................................................................ 82sslcsrgen........................................................................................................................................................................... 83sslresetcfg.........................................................................................................................................................................84testcifsshare..................................................................................................................................................................... 84testemail............................................................................................................................................................................85testfeature........................................................................................................................................................................ 85testtrap..............................................................................................................................................................................86traceroute......................................................................................................................................................................... 86

4 Contents

Page 5: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

traceroute6....................................................................................................................................................................... 87

3 CMC Property Database Group and Object Descriptions.............................................................................88Displayable Characters.................................................................................................................................................... 89idRacInfo........................................................................................................................................................................... 90

idRacProductInfo (Read Only)................................................................................................................................. 90idRacDescriptionInfo (Read Only)........................................................................................................................... 90idRacVersionInfo (Read Only)................................................................................................................................... 91idRacBuildInfo (Read Only)....................................................................................................................................... 91idRacName (Read Only)............................................................................................................................................ 91

cfgLanNetworking........................................................................................................................................................... 92cfgNicIPv4Enable (Read or Write)...........................................................................................................................92

cfgRemoteHosts.............................................................................................................................................................. 98cfgUserAdmin................................................................................................................................................................. 103cfgEmailAlert...................................................................................................................................................................106cfgSessionManagement................................................................................................................................................ 107cfgSerial...........................................................................................................................................................................109cfgOobSnmp....................................................................................................................................................................112

cfgOobSnmpProtocol............................................................................................................................................... 113cfgOobSnmpTrapFormat..........................................................................................................................................113

cfgTraps............................................................................................................................................................................113cfgTrapsSNMPv3UserId (Read Only).....................................................................................................................115cfgTrapsSNMPv3UserName................................................................................................................................... 115

cfgRacTuning................................................................................................................................................................... 115cfgRacTuneSMBVersionEnable............................................................................................................................... 116cfgRacTuneEnhancedLog (Read or Write)............................................................................................................ 116cfgRacTuneFipsModeEnable...................................................................................................................................122cfgRacTuneTLSProtocolVersionEnable................................................................................................................. 122

cfgServerInfo.................................................................................................................................................................. 122cfgActiveDirectory..........................................................................................................................................................128cfgLDAP...........................................................................................................................................................................132

cfgLDAPSRVLookupServiceName (Read or Write).............................................................................................136cfgLDAPRoleGroup........................................................................................................................................................ 136

cfgLDAPRoleGroupIndex (Read Only)...................................................................................................................136cfgStandardSchema.......................................................................................................................................................137

cfgSSADRoleGroupIndex (Read Only)...................................................................................................................138cfgSSADRoleGroupName (Read or Write)............................................................................................................138cfgSSADRoleGroupDomain (Read or Write).........................................................................................................138cfgSSADRoleGroupPrivilege (Read or Write)....................................................................................................... 138

cfgLocation......................................................................................................................................................................138cfgChassisPower............................................................................................................................................................ 140

cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)...............................................................................142cfgChassisDefaultPowerCapLowerBound (Read Only)...................................................................................... 143cfgChassisDefaultPowerCapUpperBound (Read Only)...................................................................................... 143cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write).........................................................................143cfgChassisAllow110VACOperationTimestamp (Read Only)................................................................................ 146cfgChassisMaxPowerConservationModeTimestamp (Read Only)....................................................................146

Contents 5

Page 6: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgChassisACPowerRecoveryDisable....................................................................................................................150cfgThermal...................................................................................................................................................................... 150

cfgThermalMFSPercent (Read or Write).............................................................................................................. 150cfgKVMInfo......................................................................................................................................................................151cfgLcdInfo........................................................................................................................................................................ 151

cfgLcdLocale (Read or Write).................................................................................................................................152cfgAlerting....................................................................................................................................................................... 152cfgIPv6LanNetworking.................................................................................................................................................. 153cfgCurrentLanNetworking (Read Only)...................................................................................................................... 156cfgCurrentIPv6LanNetworking (Read Only).............................................................................................................. 159cfgNetTuning................................................................................................................................................................... 161cfgRacSecurity............................................................................................................................................................... 163cfgQuickDeploy...............................................................................................................................................................165

cfgActionOnServerInsertion................................................................................................................................... 165cfgSetiDRACRootPasswordOnServerInsertion.................................................................................................... 166cfgiDRACRootPassword..........................................................................................................................................166cfgEnableiDRACLAN................................................................................................................................................166cfgEnableiDRACIPv4............................................................................................................................................... 166cfgEnableiDRACIPMIOverLAN............................................................................................................................... 167cfgEnableiDRACIPv4DHCP.....................................................................................................................................167cfgStartingiDRACIPv4Address................................................................................................................................167cfgiDRACIPv4GateWay............................................................................................................................................167cfgiDRACIPv4Netmask............................................................................................................................................168cfgEnableiDRACIPv6............................................................................................................................................... 168cfgEnableiDRACIPv6AutoConfig............................................................................................................................168cfgiDRACIPv6PrefixLength.....................................................................................................................................168cfgiDRACIPv6Gateway............................................................................................................................................169cfgReservedIPAddressNumbers.............................................................................................................................169cfgUseCMCDNSSettings........................................................................................................................................169

6 Contents

Page 7: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

IntroductionThis document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for the following:

• iDRAC for Blade Servers

• iDRAC on Rack and Tower Servers

Most of the commands mentioned in this document are applicable for multi-generation servers. That is, the commands are applicable for iDRAC6, iDRAC7, and iDRAC8. For more information on the commands applicable for a particular iDRAC version, see the iDRAC RACADM Support Matrix available at www.dell.com/esmmanuals

NOTE:

• From iDRAC version 2.00.00.00, the guide provides information specific to iDRAC. For information specific to Chassis Management Controller (CMC) M1000e, refer to Chassis Management Controller M1000e Version 5.0 RACADM Command Line Reference Guide available at www.dell.com/support/manuals.

• The appendix section in the guide provides:

– List of deprecated sub-commands.

– List of legacy groups and objects with the equivalent new groups and objects.

Topics:

• New in this release

• Supported RACADM Interfaces

• RACADM Syntax Usage

• Supported RACADM Subcommands

• Other Documents You May Need

• Accessing documents from the Dell EMC support site

• Contacting Dell

New in this release• Increased the number of support characters in slot names to 24.

• Added a new command, cfgRacTuneSMBVersionEnable, to the cfgRacTuning group.

• Added a new attribute, testcifsshare, to check whether the CIFS share is working with the current SMB version.

Supported RACADM InterfacesThe RACADM command-line utility provides a scriptable interface that allows you to locally configure or remotely configure your iDRAC. The utility runs on the management station and the managed system. It is available on the Dell OpenManage Systems Management and Documentation DVD or at www.dell.com/support/home.

The RACADM utility supports the following interfaces:

• Local — Supports running RACADM commands from the managed server’s operating system. To run local RACADM commands, install the OpenManage software on the managed server. Only one instance of Local RACADM can be executed on a system at a time. If you try to open another instance, an error message is displayed and the second instance of Local RACADM closes immediately. To download the local RACADM tool from www.dell.com/support/home, select Drivers and Downloads, select a server, and then select Systems Management > Dell Toolkit.

1

Introduction 7

Page 8: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: Local racadm and local racadm proxy runs with root user privilege.

• SSH or Telnet — Also known as Firmware RACADM. Firmware RACADM is accessible by logging in to iDRAC using SSH or Telnet. Similar to Remote RACADM, at the RACADM prompt, directly run the commands without the RACADM prefix.

• Remote — Supports running RACADM commands from a remote management station such as a laptop or desktop. To run Remote RACADM commands, install the DRAC Tools utility from the OpenManage software on the remote computer. To run Remote RACADM commands:

– Formulate the command as a SSH or Telnet RACADM command.

For more information about the options, see RACADM Subcommand Details. To download the local RACADM tool from www.dell.com/support/home, click Servers, Storage & Networking in the General Support section. Click PowerEdge, click the required PowerEdge system, and then click Drivers & downloads.

RACADM Syntax UsageThe following section describes the syntax usage for SSH or Telnet, and Remote RACADM.

SSH, Telnet, or Remote RACADMracadm -r <cmcIPAddr> -u username -p password <subcommand>racadm -r <cmcIPAddr> -u username -p password getconfig -g <group name> -o <object name>racadm <subcommand>Example

racadm getsysinforacadm -r 192.168.0.2 -u username -p xxx getsysinforacadm -r 192.168.0.2 -u username -p xxx getconfig -g cfgchassispower

SSH or Telnet RACADMracadm getconfig -g <groupname> [-o <objectname>][-i <indexnumber>]racadm <subcommand>Example

racadm getconfig -g idracinforacadm getsysinfo

Remote RACADMracadm -r <cmcIPAddr> -u <username> -p <password> <subcommand> Example

racadm -r 192.168.0.2 -u root -p xxxx getsysinfo Security Alert: Certificate is invalid - Certificate is not signed by Trusted Third Party Continuing execution.

NOTE: The following command does not display a security error:

racadm -r 192.168.0.2 -u noble -p xxx getsysinfo --nocertwarn

8 Introduction

Page 9: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

RACADM Command OptionsThe following table lists the options for the RACADM command:

Table 1. RACADM Command Options

Option Description

-r <cmcIpAddr> Specifies the controller’s IP address.

-u <username> Specifies the user name that is used to authenticate the command transaction. If the-u option is used, the -p option must be used, and the

-i option (interactive) is not allowed.

NOTE: If you are using CIFS that is registered with a domain, and are accessing the CIFS using the IP with the CIFS local user credentials, it is mandatory to enter the hostname or host IP with the -u option. The format is - <hostname/username> or <host IP/username>

-p <password> Specifies the password used to authenticate the command transaction. If the -p option is used, the -i option is not allowed.

--nocertwarn Does not display certificate related warning message.

-i <indexnumber> Specifies the index number for the indexed group, if applicable.

-g <groupname> Specifies the group name if applicable.

-o <objectname> Specifies the object name if applicable.

Supported RACADM Subcommands

Table 2. RACADM subcommands and their corresponding interface support

Subcommand CMC

Telnet/SSH/Serial Remote RACADM

"?" and "? <subcommand>" Yes Yes

help and help subcommand Yes Yes

arp Yes Yes

chassisaction Yes Yes

chassislog Yes Yes

closessn Yes Yes

clrraclog Yes Yes

clrsel Yes Yes

cmcchangeover Yes Yes

config Yes Yes

connect Yes Yes

Introduction 9

Page 10: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Subcommand CMC

Telnet/SSH/Serial Remote RACADM

deploy Yes Yes

feature Yes Yes

featurecard Yes Yes

fwupdate Yes Yes

get Yes Yes

getactiveerrors Yes Yes

getarraycfg Yes Yes

getassettag Yes Yes

getchassisname Yes Yes

getconfig Yes Yes

getdcinfo Yes Yes

getfanreqinfo Yes Yes

getflexaddr Yes Yes

getioinfo Yes Yes

getkvminfo Yes Yes

getled Yes Yes

getmacaddress Yes Yes

getmodinfo Yes Yes

getniccfg Yes Yes

getpbinfo Yes Yes

getpminfo Yes Yes

getraclog Yes Yes

getractime Yes Yes

getredundancymode Yes Yes

getsel Yes Yes

getsensorinfo Yes Yes

getslotname Yes Yes

getssninfo Yes Yes

getsvctag Yes Yes

getsysinfo Yes Yes

gettracelog Yes Yes

getversion Yes Yes

help and help subcommand Yes Yes

ifconfig Yes Yes

krbkeytabupload No Yes

netstat Yes Yes

10 Introduction

Page 11: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Subcommand CMC

Telnet/SSH/Serial Remote RACADM

ping Yes Yes

ping6 Yes Yes

racdump Yes Yes

racreset Yes Yes

racresetcfg Yes Yes

remoteimage Yes Yes

set Yes Yes

serveraction Yes Yes

setarraycfg Yes Yes

setassettag Yes Yes

setchassisname Yes Yes

setflexaddr Yes Yes

setled Yes Yes

setniccfg Yes Yes

setractime Yes Yes

setslotname Yes Yes

setsysinfo Yes Yes

sshpkauth Yes Yes

sslcertdownload No Yes

sslcertupload No Yes

sslcertview Yes Yes

sslcsrgen Yes Yes

sslresetcfg Yes Yes

testemail Yes Yes

testfeature Yes Yes

testtrap Yes Yes

traceroute Yes Yes

traceroute6 Yes Yes

Other Documents You May NeedIn addition to this guide, you can access the following guides available on the Dell Support website at www.dell.com/esmmanuals. To access the documents, click the appropriate product link.

• The Integrated Dell Remote Access Controller 8 (iDRAC8) User’s Guide provides information about configuring and using an iDRAC to remotely manage and monitor your system and its shared resources through a network.

• The iDRAC RACADM Support Matrix provides the list of sub commands and objects that are applicable for a particular iDRAC version.

• Documentation specific to your third-party management console application.

• The Dell OpenManage Server Administrator’s User’s Guide provides information about installing and using Dell OpenManage Server Administrator.

Introduction 11

Page 12: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• The Dell Update Packages User's Guide provides information about obtaining and using Dell Update Packages as part of your system update strategy.

• The Glossary provides information about the terms used in this document.

The following system documents are also available to provide more information about the system in which iDRAC is installed:

• The Hardware Owner’s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components.

• Documentation for any components you purchased separately provides information to configure and install the options.

• Release notes or readme files may be included to provide last-minute updates to the system or documentation or advanced technical reference material intended for experienced users or technicians.

Updates are sometimes included with the system to describe changes to the system, software, and/or documentation. Always read the updates first because they often supersede information in other documents.

See the Safety and Regulatory information that is shipped with your system.

NOTE: Warranty information may be included within this document or as a separate document.

Accessing documents from the Dell EMC support siteYou can access the required documents using the following links:

• For Dell EMC Enterprise Systems Management documents — www.dell.com/SoftwareSecurityManuals

• For Dell EMC OpenManage documents — www.dell.com/OpenManageManuals

• For Dell EMC Remote Enterprise Systems Management documents — www.dell.com/esmmanuals

• For iDRAC and Dell EMC Lifecycle Controller documents — www.dell.com/idracmanuals

• For Dell EMC OpenManage Connections Enterprise Systems Management documents — www.dell.com/OMConnectionsEnterpriseSystemsManagement

• For Dell EMC Serviceability Tools documents — www.dell.com/ServiceabilityTools

• a Go to www.dell.com/Support/Home.

b Click Choose from all products.

c From All products section, click Software & Security, and then click the required link from the following:

– Enterprise Systems Management

– Remote Enterprise Systems Management

– Serviceability Tools

– Dell Client Command Suite

– Connections Client Systems Management

d To view a document, click the required product version.

• Using search engines:

– Type the name and version of the document in the search box.

Contacting DellNOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog.

Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues:

1 Go to Dell.com/support.

2 Select your support category.

3 Verify your country or region in the Choose a Country/Region drop-down list at the bottom of the page.

4 Select the appropriate service or support link based on your need.

12 Introduction

Page 13: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

RACADM Subcommand DetailsThis section provides detailed description of the RACADM subcommands including the syntax and valid entries.

Topics:

• Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands

• Racadm help and help with subcommand

• Help and help subcommand

• arp

• chassisaction

• chassislog

• closessn

• clrraclog

• clrsel

• cmcchangeover

• config

• connect

• deploy

• eventfilters

• feature

• featurecard

• fwupdate

• get

• getactiveerrors

• getarraycfg

• getassettag

• getchassisname

• getconfig

• getdcinfo

• getflexaddr

• getfanreqinfo

• getioinfo

• getkvminfo

• getled

• getmacaddress

• getmodinfo

• getniccfg

• getpbinfo

• getpminfo

• getraclog

• getractime

• getredundancymode

2

RACADM Subcommand Details 13

Page 14: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• getsel

• getsensorinfo

• getslotname

• getssninfo

• getsvctag

• getsysinfo

• gettracelog

• getversion

• ifconfig

• krbkeytabupload

• netstat

• ping

• ping6

• racdump

• racreset

• racresetcfg

• remoteimage

• set

• serveraction

• setarraycfg

• setassettag

• setchassisname

• setflexaddr

• setled

• setniccfg

• setractime

• setslotname

• setsysinfo

• sshpkauth

• sslcertdownload

• sslcertupload

• sslcertview

• sslcsrgen

• sslresetcfg

• testcifsshare

• testemail

• testfeature

• testtrap

• traceroute

• traceroute6

Guidelines to Quote Strings Containing Special Characters When Using RACADM CommandsWhen using strings that contain special characters, use the following guidelines:

Strings containing the following special characters must be quoted using double quotation marks:

• $ (dollar sign)

14 RACADM Subcommand Details

Page 15: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• " (double quotation mark)

• ` (backward quotation mark)

• \ (backward slash)

• ~ (tilde)

• | (vertical bar)

• ( (left parentheses)

• ) (right parentheses)

• & (ampersand)

• > (greater than)

• < (less than)

• # (pound)

• ASCII code 32 (space)

There are different escaping rules for double quotation marks.

For using double quotation marks:

The following characters must be escaped by prepending a backward slash:

• $ (dollar sign)

• " (double quotation mark)

• ` (back quotation mark)

Racadm help and help with subcommand

Table 3. Details of Racadm help and help with subcommand

Description Displays all the subcommands you can use with the RACADM command and a one-line description about each

subcommand.

? followed by <subcommand> displays the syntax for the specified command.

To use this subcommand, you must have the CMC Login User privilege.

You can also use the help and help <subcommand> commands to obtain the same information.

Synopsis racadm ?racadm ? <subcommand>

Input N/A

Output N/A

Example for RACADM?

The following output example shows the actual output for the RACADM? command. Descriptions shown in this example may vary slightly

from the descriptions in your RACADM session.

racadm ? help -- list racadm subcommand description help <subcommand> -- display usage summary for a subcommand ? -- list racadm subcommand description ? <subcommand> -- display usage summary for a subcommand arp -- display the networking arp table chassisaction -- execute power-up/down/cycle or reset operation chassislog -- display the chassislog closessn -- close a session clrraclog -- clear the CMC log

RACADM Subcommand Details 15

Page 16: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

clrsel -- clear the System Event Log (SEL) cmcchangeover -- changes the redundant state of the CMC from active to standby and vice versa config -- modify CMC configuration properties connect -- connect to switch or blade serial console deploy -- deploy blade or IOM by specifying required properties feature -- display features active on the chassis / feature deactivation featurecard -- feature card status and list the available features fwupdate -- update the firmware on a CMC, server, IOM inf or KVM get -- save CMC configuration properties to a file getactiveerrors -- display CMC active errors getassettag -- display asset tag getchassisname -- get the chassisname getconfig -- display CMC configuration properties getdcinfo -- display general I/O module and DC configuration information getfanreqinfo -- display fan request information for Servers and Switches getflexaddr -- display Flexaddress enablement status for all slots and fabrics. getioinfo -- display general IO information and stack information getkvminfo -- display the KVM module information getled -- display the LED settings on a module getmacaddress -- get MAC/WWN addresses getmodinfo -- get module configuration and status information getniccfg -- display network settings for modules getpbinfo -- get power budget status information getpminfo -- get power management status information getraclog -- display the CMC log getractime -- display the current CMC time getredundancymode -- gets the redundancy mode of the CMC getsel -- display records from the System Event Log (SEL) getsensorinfo -- display system sensors getslotname -- gets the name of the slot in the chassis getssninfo -- display session information getsvctag -- display service tag information getsysinfo -- display general CMC and system information gettracelog -- display the CMC diagnostic trace log getversion -- display version information for modules getarraycfg -- display's storage array properties ifconfig -- display network interface information jobqueue -- Jobqueue of the jobs currently scheduled krbkeytabupload -- upload an Kerberos Keytab to the CMC netstat -- display routing table and network statistics ping -- send ICMP echo packets on the network ping6 -- send ICMP echo packets on the network racdump -- display CMC diagnostic information racreset -- perform a CMC or RAC reset operation racresetcfg -- restore the CMC configuration to factory defaults remoteimage -- connect, disconnect or deploy a media file on a remote server serveraction -- perform system power management operations set -- import saved CMC configuration from a file setassettag -- set the asset tag for the specified module setchassisname -- sets the name of the chassis setflexaddr -- enable/disable the Flexaddress feature on a per fabric, per slot basis. setled -- set state of the LEDs on a module setniccfg -- modify network configuration properties setractime -- set the time on the CMC setslotname -- sets the name of the slot in the chassis setsysinfo -- set the chassis name and chassis location setarraycfg -- configure's storage array properties sshpkauth -- manage PK Authentication keys and accounts sslcertdownload -- download an SSL certificate from the CMC sslcertupload -- upload an SSL certificate to the CMC sslcertview -- display a CA/server certificate in the CMC sslcsrgen -- generate a certificate CSR from the CMC sslresetcfg -- generate a new self-signed certificate testemail -- test CMC e-mail notifications testfeature -- test CMC feature x testtrap -- test CMC SNMP trap notifications traceroute -- determine the route of a packet traceroute6 -- determine the route of a packet wsman -- perform wsman client functions for servers.

16 RACADM Subcommand Details

Page 17: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example for RACADM? <subcommand>

racadm ? getsysinfogetsysinfo -- display general CMC and system informationUsage:racadm getsysinfo [-d] [-c] [-A] [-4] [-6]-----------------------------------------------------------Valid Options:-d : show CMC information-c : show chassis information-A : do not show headers or labels-4 : show CMC IPv4 information-6 : show CMC IPv6 information

Help and help subcommand

Table 4. Help and help subcommand

Description Lists all the subcommands available for use with RACADM and provides a short description about each subcommand. You may also type a subcommand, group, object or Fully Qualified Descriptor (FQDD) name after help.

Synopsis • racadm help• racadm help <subcommand>• racadm help —g <groupname>• racadm help –g <groupname> —o <objectname>

Input • <subcommand> — specifies the subcommand for which you need the help information.

• <device name> — specifies the device name such as iDRAC, BIOS, NIC, LifecycleController, FC, system, or Storage.

• <group> — specifies the group name supported by the corresponding device.

• <object> — specifies the object for the entered group.

Output • The help command displays a complete list of subcommands.

• The racadm help <subcommand> command displays information for the specified subcommand only.

• The racadm help —g <groupname> command displays information for the specified group.

• The racadm help —o <objectname> command displays information for the specified object.

• The racadm help <device name> <Group> command displays information for the specified group.

• The racadm help <device name> <Object> command displays information for the specified object.

• The racadm help <device name> <Group> <Object> command displays information for the specified object.

arp

Table 5. arp table

Description Displays the contents of the Address Resolution Protocol (ARP) table. ARP table entries cannot be added or deleted.

To use this subcommand, you must have Execute Diagnostic Commands.

Synopsis racadm arp

Input N/A

RACADM Subcommand Details 17

Page 18: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example racadm arp

Table 6. Output

Address HW Type HW Address Mask Device

192.168.1.1 Ether 00:0d:65:f3:7c:bf C eth0

chassisaction

Table 7. Details of chassisaction attribute

Description Runs a power action on the chassis, KVM or a switch.

To use this subcommand, you must have the Chassis Control Administrator privilege.

Synopsis racadm chassisaction [-m <module>] <action>

Input • -m <module> — Module on which you want to carry out the action. Values are:

• —chassis — is the default value if -m is not specified.

—switch-<n> where n=1–6

—kvm

• <action> — Action that you want to run on the specified module. Values are:

• —powerdown — (Chassis only) Powers down the chassis.

—powerup — (Chassis only) Powers up the chassis.

—powercycle — Power cycles the module.

NOTE: If a server takes longer duration to turn off gracefully after the chassis power cycle is initiated, CMC stops functioning indicating that graceful shutdown of the server was unsuccessful. In this case, turn off the system ungracefully or try to gracefully turn off the system again.

—nongraceshutdown — (Chassis only) Turns off the chassis ungracefully.

—reset — Performs a hard reset of the module.

When <module> = kvm or switch, <action> must be powercycle or reset.

Output None

Example • Perform a reset of switch-3:racadm chassisaction -m switch-3 resetModule power operation successful.

• Perform a non graceful shutdown of the chassis:racadm chassisaction -m chassis nongraceshutdown

18 RACADM Subcommand Details

Page 19: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

chassislog

Table 8. Details of chassislog attribute

Description Displays chassis log and management operations.

Synopsis racadm chassislog <chassislog command type>

Input chassislog command types:

• view — View chassis log

– To View chassis logracadm chassislog view

• export — Export to local disk and network share

– Export chassis log to local diskracadm -r 192.168.0.32 chassislog export -f filename.log

– Export chassis log to a remote network share CIFSracadm chassislog export -f Mylog.xml -u admin -p mypass -l //192.168.x.x/share

– Export chassis log to a remote network share NFSracadm chassislog export -f Mylog.xml -l 192.168.x.x:/home/lclog_user

– Export the chassis log to a local share using remote racadmracadm -r 192.168.x.x -u root -p calvin chassislog export -f Mylog.xml

– Enable the quick deploy parameter in CMC DNS Settingsracadm deploy -q -e 1

– Update quick deploy parametersracadm deploy -q --qd

• clear — Clear chassis log

– To clear chassis logracadm chassislog clear

NOTE: To clear the chassis log, you must have the Clear Logs Administrator privilege.

NOTE: racadm chassislog export -f <filename> is supported only for remote interfaces.

closessn

Table 9. Details of closessn attribute

Description Closes a communication session on the device. Use getssninfo to view a list of sessions that can be closed using this command.

To run this subcommand, you must have the Administrator permission.

NOTE: This subcommand ends all the sessions other than the current session.

Synopsis • racadm closessn –i <session_ID>• racadm closessn -a• racadm closessn -u <username>

Input • —i <session_ID> — The session ID of the session to close, which can be retrieved using RACADM getssninfo subcommand.

Session running this command cannot be closed.

RACADM Subcommand Details 19

Page 20: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• —a — Closes all sessions.

• —u <username> — Closes all sessions for a particular user name.

• For Remote RACADM, use either the —u option or the —i option.

Output Successful or error message is displayed.

Example • Closes the session 1234.racadm closessn -i 1234

• Closes all the sessions other then the active session for root user.racadm closessn –u root

• Closes all the sessions.racadm closessn –a

clrraclog

Table 10. Details of clrraclog attribute

Description Deletes the CMC log.

Synopsis racadm clrraclog

Input N/A

clrsel

Table 11. Details of clrsel attribute

Description Removes all the existing records from the System Event Log (SEL).

To use this subcommand, you must have Clear Logs permission.

Synopsis racadm clrsel [-m <module>]

Input -m <module> must be one of the following values:

• server-<n> — where n=1 to 16

• server-<nx> — where n=1 to 8; x = a, b, c, d (lower case)

Example • racadm clrselThe SEL was cleared successfully

• racadm clrsel -m server-1Clear SEL log on server 1

cmcchangeover

Table 12. Details of cmcchangeover attribute

Description Changes the state of the CMC from active to standby, or from standby to active, in a redundant CMC configuration. This subcommand is useful for remote debugging or testing purposes

20 RACADM Subcommand Details

Page 21: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

To use this subcommand, you must have the Administrator privilege.

NOTE: This command is applicable only in redundant CMC environments. For more information, see the "Understanding the Redundant CMC Environment" section of the Dell Chassis System User Guide.

Synopsis racadm cmcchangeover

Input N/A

Output CMC failover initiated successfully.

Example racadm cmcchangeover

config

Table 13. Details of config attribute

Description Allows you to set iDRAC configuration parameters individually or to batch them as part of a configuration file and then modify iDRAC configuration properties. If the data is different, the iDRAC object is written with a new value.

NOTE: This subcommand will be deprecated in the later versions. For information about configurations, see the set subcommand.

Synopsis • racadm config -g <group> -o <object> <value>• racadm config -g <group> -o <object> -i <index> <value>• racadm config -f <filename> -o [-c] [-p] [-continue]

NOTE:

• The configuration file retrieved using remote RACADM is not interoperable. For the config racadm -r 192.168.0 -u root -p xxx config -f c:\config.txt command, use the configuration file retrieved from the same interface. For example, for the config racadm -r 192.168.0 -u root -p xxx config -f c:\config.txt , use the file generated from getconfig command racadm -r 192.168.0 -u root -p xxx getconfig -f c:\config.txt.

• -f is only applicable for remote RACADM.

racadm config -g <group> -o <object> <value> [-m <module>]

Input • -f — The -f <filename> option causes config to read the contents of the file specified by <filename> and configure iDRAC. The file must contain data in the format specified in the section Parsing Rules in the iDRAC User’s Guide available at www.dell.com/idracmanuals.

NOTE: The -f option is not supported for the Serial or Telnet or SSH console.

• -continue — This option is used with -f option only. If configuration through file is unsuccessful for a group, then configuration continues with the next group in the file. If this option is not used, then configuration stops when it is unsuccessful for a particular group. After the unsuccessful group, the rest of the groups are not configured.

• -p — This option must be used with the -f option. It directs config to delete the password entries contained in the config file -f <filename> after the configuration is complete.

To apply the password, you must remove the preceding Read-Only marker '#' in the config file before executing the config -f command.

• -g — The -g <groupName>, or group option, must be used with the -o option. The <group> specifies the group containing the object that is to be set.

• -o — The -o <objectName>, or object option, must be used with the -g option. This option specifies the object name that is written with the string

• <value> — Value to set to configuration object.

• -i — The -i <index>, or index option, is valid only for indexed groups and can be used to specify a unique group (used with -g and -o). The <index> is a decimal integer from 1 through n, where n can vary from 1 to maximum number of indexes a particular group supports. If -i <index> is not specified, a value of 1 is

RACADM Subcommand Details 21

Page 22: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

assumed for groups, which are tables that have multiple entries. The index is specified by the index value, not a named value.'nx' is allowed for servers.

• -c — This option performs validation but do not configure.

Output This subcommand generates error output for any of the following reasons:

• Invalid syntax, group name, object name, index or other invalid database members.

• If the RACADM command-line interface is unsuccessful.

Examples • To configure a single property of a group:racadm config -g cfgSerial -o cfgSerialBaudRate

• Modify a user password:racadm config -g cfgUserAdmin -o cfgUserAdminPassword -i 3 newpassword

• Configure a RAC from a configuration file:racadm config -f config.txt

• Configure a RAC from a configuration file and continue if a group fails to get configured:racadm set -f config.txt --continue

connect

Table 14. Details of connect attribute

Description Connects to the switch or blade server serial console.

NOTE: This subcommand is only supported on the firmware interface(s).

Synopsis • racadm connect [-b] —m <module>

Input -b — Connects to the switch or console using the binary mode. -b is an optional; a server or a switch must be present.

NOTE: If you use the -b option, reset the CMC to end the connect operation.

-m <module> — Must be one of the following values:

• server –<n> — where n=1–16

• server –<nx> — where n=1–8; x = a, b, c, d (lower case)

• switch –<n> — where n = 1 to 6 or <a1 | a2 | b1 | b2 | c1 | c2>

Example • Connect to I/O Module 1 serial console:racadm connect -m switch-1

• Connect to server 1 serial console:racadm connect -m server-1

deploy

Table 15. Details of deploy attribute

Description Deploys blade server or IOM by specifying the required properties.

To use this subcommand, you must have the Server Administrator privilege.

22 RACADM Subcommand Details

Page 23: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: Use setniccfg to configure static IP address, subnet mask, and gateway, and DHCP, speed and duplex properties.

Synopsis • racadm deploy -m server-<n> -u root -p <password> -s <ipaddress> <subnet> <gateway> -b <device> -o no | yes

• racadm deploy -m server-<n> -u root -p <password>-s -6 <ipv6Address> <prefixlen> <gateway> -b <device> -o no | yeswhere <prefixlen> must be a number between 0 and 128.

• racadm deploy -m server-<n> -u root -p <password> -d [-6]• racadm deploy -m switch-<n> -u root -p <password>• racadm deploy -m switch-<n> -v SNMPv2 <snmpCommunityString> ro• racadm deploy -a [server/switch] -u root -p <password>• racadm deploy -q [-n <numofblades>]

Input • —b <device> — Specifies the first boot device must be used with -o. Use with-m <module> to specify for an individual server, or with an -a for all servers.

Legal values are: None, PXE, HDD, CD-DVD, vFDD, vCD-DVD, iSCSI, SD, FDD, RFS.

• -o no/yes — Indicates if the server must start from the device once. Use this option with -b option.

Use with -m <module> to specify for an individual server, or with -a for all servers.

• -a — server/switch. Applies options to all modules present in the chassis of the given module type. Specify the value as server or switch. Default value is server. Switches must support Ethernet Management.

• -u <username> — Indicates that the <password> is supplied for the root user on the server or switch. Root is a constant parameter, the only value that is valid with the —u option.

• —m <module> — Specifies the server or switch you want to configure.

Legal values:

– server-<n>, where n=1–16

– server-<nx>, where n=1– 8; x = a,b,c,d (lower case)

– switch-<n>, where n=1– 6

• -p <password> — Specifies the password for the root user on the server or switch. For switches, valid passwords are 6–32 ASCII characters in length, ranging in value 32–125 (decimal). For servers, valid passwords are 1–20 ASCII characters in length, ranging in value 32–126 (decimal).

• -s <ipaddress> <subnet> <gateway> — Sets the IP address, subnet mask, and gateway for the specified server.

– ipaddress — A string representing a valid IP address. For example, 192.168.0.20.

– subnet — A string representing a valid subnet mask. For example, 255.255.255.0.

– gateway — A string representing a valid gateway address. For example, 192.168.0.1.

• -d — Enables DHCP for the specified server.

The -s and -d options cannot be used together in the same command.

• -6 — Enables IPv6 auto configuration (when used with -d). Sets static IPv6 addresses (when used with -s).

• -v SNMPv2 <snmpCommunityString> ro — Specifies the SNMP community string for switches. Valid community strings are 1–20 characters in length, with valid ASCII characters in the range [33–125] (decimal). Protocol version set to SNMPv2. Permission on community string is read-only.

• -q — Displays or modifies the quick deploy parameters.

• -n <numofblades> — Specifies the number of reserved IP addresses for quick deploy. The allowed values are: 8, 16, and 32.

NOTE: The -q option must be specified with the -n option.

• -e — Uses the CMC DNS settings for quick deploy. The legal values are:

– 1 — Enable

– 0 — Disable

• --qd — Updates the quick deploy parameters to the servers. This option works only with the -q option.

Output None

RACADM Subcommand Details 23

Page 24: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example • Set root password, configure static IPV4 address, set first boot device to HDD, and enable boot once for server-1.racadm deploy -m server-1 -u root -p <password> -s 192.168.0.20 255.255.255.0 192.168.0.1 -b HDD -o yes

• Set root password, configure static IPV6 address, set first boot device to HDD, and enable boot once for server-1.racadm deploy -m server-1 -u root -p <password> -s -6 1 2001:DB8::2 64 2001:DB8::1 -b HDD -o yes

• Set root password and enable DHCP for server-3.racadm deploy -m server-3 -u root -p <password> -d

• Set user name and password for switch-2.racadm deploy -m switch-2 -u <username> -p <password>

• Set SNMP community string for switch-2.racadm deploy -m switch-2 -v SNMPv2 DemoCommunityString ro

• Set root password to Calvin for all servers.racadm deploy -a -u root -p calvin

• Set user name and password for all switches.racadm deploy -a switch -u <username> -p <password>

• View the quick deploy parameters.racadm deploy -q

• Modify the number of reserved IP addresses for quick deploy.racadm deploy -q -n 8

eventfilters

Table 16. eventfilters

Description Gets, sets, and displays the list of event filter settings.

To use this subcommand with the get option, you must have the CMC Login User privilege.

Synopsis racadm eventfilters <eventfilters command type>racadm eventfilters get -c <alert descriptor>racadm eventfilters set -c <alert descriptor>-n <notifications>

NOTE: The general format of an alert descriptor:

cmc.alert.category.[subcategory].[severity]where, category is mandatory, but subcategory and severity are optional. A severity cannot precede a subcategory.

Valid category values are:

• All

• System

• Updates

• Audit

• Config

Valid severity values are:

• Critical

• Warning

• Informational

24 RACADM Subcommand Details

Page 25: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Valid examples of alert descriptors are:

• cmc.alert.all• cmc.alert.audit• cmc.alert.audit.lic• cmc.alert.audit.warning• cmc.alert.audit.lic.critical

Input • get — Displays the list of event filter settings.

• set — Configures the actions and notifications for a given event filter configuration.

• -c — Alert descriptor of the specific event filter.

• -n — The notification to be sent when the event occurs. Valid values are all, snmp, ipmi, lcd, email, or none. You can append multiple notifications separated by a comma. You cannot enter the values all or none with other notifications.

NOTE: If both event generation interval and notifications are configured and there is an error while configuring the notifications, the event generation interval is not set. The valid values are from 0–365. 0 disables the event generation.

Example • Display all available event filter configurations:nracadm eventfilters get -c cmc.alert.all

• Display eventfilter configurations for a specific category. For example, audit:racadm eventfilters get -c cmc.alert.audit

• Display eventfilter configurations for a specific subcategory. For example, licensing under the audit category:racadm eventfilters get -c cmc.alert.audit.lic

• Display eventfilter configurations for a specific severity. For example, warning under the audit category:racadm eventfilters get -c cmc.alert.audit.warning

• Display eventfilter configurations for a specific severity and subcategory. For example, a severity of warning in the subcategory licensing under audit category:racadm eventfilters get -c cmc.alert.audit.lic.warning

• Clear all available alert settings:racadm eventfilters set -c cmc.alert.all -n none

• Configure using severity as a parameter. For example, all informational events in storage category are assigned poweroff as action, and email and snmp as notifications:racadm eventfilters set -c cmc.alert.storage.info -n email,snmp

• Configure using subcategory as a parameter. For example, all configurations under the licensing subcategory in the audit category are assigned poweroff as action and all notifications are enabled:racadm eventfilters set -c cmc.alert.audit.lic -n all

• Configure using subcategory and severity as parameters. For example, all Information events under the licensing subcategory in the audit category are assigned poweroff as action and all notifications are disabled: racadm eventfilters set -c cmc.alert.audit.lic.info -n none

feature

Table 17. Details of feature attribute

Description Displays all active chassis features. The information displayed includes feature name, date activated and the serial number of the SD card used to activate the feature.

Dell Feature Cards may contain more than a feature. After any feature included on a Dell Feature Card is activated on a chassis, any other features that may be included on that Dell Feature Card cannot be activated on a different chassis.

RACADM Subcommand Details 25

Page 26: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: To use this subcommand to deactivate FlexAddress, you must have the Chassis Configuration Administrator privilege. A user with login privileges can view status only.

NOTE: To deactivate FlexAddress features, the chassis must be turned off.

Synopsis • racadm feature -s• racadm feature -d -c <featurename>• racadm feature -r -c ExtendedStorage

Input -s –Displays the status of active features.

-d –Deactivates feature specified in -c option.

NOTE: When the FlexAddress and FlexAddressPlus feature are active, deactivating one of them results in deactivation of the other feature also.

-r—Reformats damaged or unformatted extended storage media.

CAUTION: Using the -r switch deactivates the extended storage feature, if active; reformats the SD card in the active CMC card slot; and may Restart the active CMC.

-c— <featurename> — must be one of the following:

• flexAddress• flexAddressPlus• ExtendedStorage (with -d, or -r)

NOTE: The —a option is not supported for CMC 5.0.

Example • Display the current status of all chassis features:racadm feature -s

• Deactivate the FlexAddressPlus feature on the chassis:racadm feature -d -c FlexAddressPlus

featurecard

Table 18. Details of featurecard attribute

Description Verifies proper SD card installation and displays the SD card status.

To use this subcommand, you must have the Chassis Configuration Administrator privilege.

Synopsis racadm featurecard -s

Input -s — Lists active SD card features and SD card status.

Output • No feature card inserted — Action: To verify that the SD card was properly inserted, check the CMC. In a redundant CMC configuration, make sure the CMC with the SD feature card installed is the active CMC and not the standby CMC.

• The feature card inserted is valid and contains the following feature(s) FlexAddress: The feature card is bound to this chassis — Action: No action required.

26 RACADM Subcommand Details

Page 27: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• No features active on the chassis — Action: Install the SD card into the CMC.

• The feature card inserted is valid and contains the following feature(s) FlexAddress: The feature card is bound to another chassis, svctag = ABC1234, SD card SN = 01122334455Action: Remove the SD card; locate and install the SD card for the current chassis.

• The feature card inserted is valid and contains the following feature(s) FlexAddress: The feature card is not bound to any chassisAction: The feature card can be moved to another chassis, or can be reactivated on the current chassis. To reactivate on the current chassis, enter racadm racreset until the CMC module with the feature card installed becomes active.

Example $ racadm featurecard -sThe feature card inserted is valid, serial number TEST0123456789012345678The feature card contains the following feature(s):FlexAddress: The feature is bound to this chassisFlexAddressPlus: The feature is bound to this chassisExtendedStorage: The feature is bound to this chassis

fwupdate

Table 19. Details of fwupdate

Description Allows you to update the firmware on the KVM, active CMC, standby CMC, iDRAC or an IOM infrastructure device. You can:

• Check the firmware update process status.

• Update CMC from FTP or TFTP server by providing an IP address and optional path.

• Update CMC from the local file system using Remote RACADM.

• There can only be a single update operation in progress at any time. In addition, the fwupdate subcommand may only update one or more devices of a single kind at a time.

NOTE: CMC firmware update is supported only for the firmware versions 3.10, 3.20, 3.21, 4.0, 4.10, 4.11, 4.30, 4.31, 4.45, and 4.5. For any version other than these, first update to any of these versions, and then update to the required version.

To use this subcommand, you must have the Chassis Configuration Administrator privilege.

NOTE: The fwupdate command is not supported for iDRAC7 or later. Use the CMC GUI to perform the operation.

NOTE:

• Running the fwupdate subcommand to update the firmware on the active CMC resets itself and all the network connections are dropped. During update of all other modules, including the standby CMC, the active CMC continues to run normally without resetting.

• In a chassis supported by DC PSUs, an error message is displayed if you attempt to update the firmware with a version without DC PSU support.

• The fwupdate subcommand generates an error when used on the extension slot of a multi-slot server.

• While Lifecycle Controller is running for racadm commands, you cannot perform other operations which need Lifecycle Controller Partition. If the Lifecycle Controller Partition is unreleased (because of improper closure of racadm command in the partition), then wait 20-35 minutes to clear the Lifecycle Controller Partition

Signed CMC Firmware Image

• For Dell’s 13th generation of PowerEdge servers and later, CMC firmware includes a signature which is verified by CMC before update to ensure the authenticity of the uploaded firmware. The firmware update process is successful only if the firmware image is authenticated by CMC to be a valid image from the service provider and has not been altered. The firmware update process is stopped if CMC cannot verify the signature of the uploaded firmware image.

RACADM Subcommand Details 27

Page 28: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• Upload firmware image from TFTP server and start firmware update.

NOTE: Run the firmware update command through only one remote racadm session at a time.

Synopsis For SSH or Telnet or Serial:

racadm fwupdate -g -u -a <tftp_server_ip_address_or_FQDN> -d <path> [-m <module>]racadm fwupdate -f <ftp_server_ip_address_or_FQDN> <username> <password> -d <path> [-m <module>]racadm fwupdate -u -m iominf-<n>racadm fwupdate -s [-m <module>]racadm fwupdate -c [-m <module>]For Remote RACADM:

racadm fwupdate -p -u -d <path> [-m <module>]racadm fwupdate -g -u -a 192.168.0.10 -d firmimg.cmc -m cmc-activeracadm fwupdate -r [-m <module>]racadm -r 192.168.0.120 -u <username> -p <password> fwupdate -p -u -d firming.cmcWhen using FTP, if you provide the full path to the image file on the CLI, then the CMC uses that path to locate that file on the host. If full path is not provided and the host system is running Linux or another variant of UNIX, then CMC searches the home directory of the specified user for the file. If the host system is running Windows, then a default folder, such as C:\ftproot is searched.

NOTE: When attempting to run firmware update task, if the firmware image path length is greater than 256 characters, remote RACADM client exits with the error message "ERROR: Specified path is too long".

NOTE: When attempting to run firmware update task using racadm fwupdate command, if the firmware image path length is greater than 256 characters. Remote RACADM client exits with the error message "ERROR: Specified path is too long".

Input • —u — Performs the firmware update operation (used with -p and -g).

• —s — Displays the status of the firmware update. Use this option by itself. Lists active SD card features and SD card status.

NOTE: Use —m to display the status of the module update. Omit -m to display the status of the active

CMC update.

NOTE: The value all is used only to obtain the status of all targets to update.

• -g — Downloads the firmware update using the TFTP server.

• -a — The IP Address option specifies the TFTP server IP address, used with -g option.

Specifies the TFTP server IP address or FQDN used for the firmware image (used with -g).

• -d — The -d, or directory option specifies the directory on the TFTP server or on CMC’s host server, where the firmware update file resides.

Specifies the source path where the firmware image resides.

Default: Designated TFTP default directory on that host for the file if -g option is absent. If -g is used, it defaults to a directory configured on the TFTP server.

• -p — The -p option is used to upload the firmware image from the client.

NOTE: This option is only supported on the remote interface(s) and Windows operating systems.

• -m <module> — Specifies the module or device to be updated. <module> is one of the following values:

– cmc-active — default state if –m is not specified.

28 RACADM Subcommand Details

Page 29: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

– cmc-standby– kvm– server-<n> — where n=1–16

– server-<nx> — where n=1–8; x = a, b, c, d (lowercase)

– server-<g> <generation> — where generation = iDRAC or iDRAC6 only.

– iominf-<n> — where n = 1–6

NOTE: Multiple modules can be specified except iominf-<n>, for example, –m <module 1> –m <module 2> and so on.

• -f — Specifies the FTP server IP address or FQDN, username, and password used for firmware image. Applies FTP download process for firmware update.

• -c — Cancels an ongoing firmware update. The cancel operation is supports the following values:

– cmc-active — This is the default option if -m is not specified.

– cmc-standby– server-<n> — where n = 1 to 16

– server-<nx> — where n = 1 to 8; x = a to d (lowercase)

– server-<g> — where g = generation (iDRAC, iDRAC6)

– iominf-<n> — where n = 1 to 6

– kvm

NOTE: Omit -m to cancel an active CMC update.

CMC version 3.00 accepts IPv4 or fully qualified domain names (FQDN) for both FTP and TFTP servers.

NOTE: CMC does not support FTP over IPv6.

NOTE: You can specify the cmc-active and cmc-standby modules at the same time along with one or more server-n modules. This option enables the devices to be updated together.

NOTE: Verify that the update applied to servers for a particular generation has been validated for all impacted server models.

Output Displays a message indicating the operation that is being performed.

Example • Upload the firmware image from the TFTP server and start the firmware update.racadm fwupdate -g -u -a 192.168.0.2 -d firmimg.cmc -m cmc-active

TFTP firmware update has been initiated. This update process may take several minutes to complete.

• Upload the firmware image from the FTP server and start the firmware update.racadm fwupdate -f 192.168.0.100 fred xxx -d firmimg.cmc -m cmc-active

• Upload a firmware image from the client and start firmware update.racadm fwupdate -p -u -d firmimg.cmc

• Start IOM infrastructure firmware update.racadm fwupdate -u -m iominf-1

• Update firmware on both the CMCs.racadm fwupdate -g -u -a 192.168.0.2 -d firmimg.cmc -m cmc-active -m cmc-standby

• Update firmware on multiple servers.racadm fwupdate -g -u -a 192.168.0.2 -d firmimg.imc -m server-1 -m server-2 -m server-3

• Update firmware on servers of iDRAC generation.racadm fwupdate -g -u -a 192.168.0.2 -d firmimg.imc -m server-iDRAC

• Update firmware on multiple IOM infrastructure devices.racadm fwupdate -u -m iominf-4 -m iominf-5 -m iominf-6

• Query the status of all firmware targets to be updated.

RACADM Subcommand Details 29

Page 30: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

racadm fwupdate -s -m all• Query the current status of the firmware update process for a particular module.

racadm fwupdate -s -m <module>• Download firmware update file from a specified location on the TFTP server at a specific IP address.

racadm fwupdate -g -u -a 192.168.0.2 -d <path>

After the image file is downloaded from the TFTP server, the update process begins. When completed, CMC is reset.

• Read the status of the firmware update.racadm fwupdate -s

• Cancel a firmware update in progress.racadm fwupdate –c

NOTE: Firmware update from local RACADM (using -p -u -d options) is not supported on Linux OS.

NOTE: These commands specifically apply to an active-CMC update.

Signed CMC Firmware Image:

• To get the firmware update status:

racadm fwupdate –s –m cmc-activeInvalid firmware: The uploaded firmware image does not contain a verification signature.

Table 20. Firmware update methods on CMC servers

FW Update Method CMC

Local RACADM No

Local RACADM-TFTP No

Local RACADM-FTP No

Remote RACADM Yes

Remote RACADM-TFTP Yes

Remote RACADM-FTP Yes

Firmware RACADM-TFTP Yes

Firmware RACADM-FTP Yes

get

Table 21. Details of get attribute

Description Saves CMC configuration properties to a file.

NOTE: If CMC is not in the network, you cannot export the chassis configuration profile to a remote network share with proxy using the get command. But, you can export the chassis

configuration profile to the local management station.

30 RACADM Subcommand Details

Page 31: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: CMC does not support FTP over IPv6.

Synopsis racadm get -f <filename>racadm -r <CMC IP> -u <username> -p <password> get -f <filename>racadm -r <CMC IP> -u <username> -p <password> get -f <filename> -t xmlracadm get -f <filename> -t xml -u <username> -p <password> -l <CIFS share>racadm get -f <filename> -t xml -l <NFS share>

Input • –f: save event filter configurations to a file.

• -u: user name of the remote share where the file must be exported.

• -p: password for the remote share where the file must be exported.

• -l: network share location where the file must be exported.

• -t: specify the file type to be exported. Valid value is xml. This option is case-insensitive.

• --clone: export the cloned configuration file. Only the XML file format is supported. The configuration file can be exported to a local or remote share.

NOTE: Clone configuration file is default if --clone or --replace is not specified.;

• --replace: export the replaced configuration file. Only XML file format is supported. The configuration file can be exported to a local or remote share.

• --includeph: include password hash attributes

Example • Export the CMC XML configuration to a local share using remote racadmracadm -r 192.168.0.120 -u abc -p <password> get -f file.xml -t xml

• Export the CMC XML configuration to a CIFS shareracadm get -f file.xml -t xml -u myuser -p mypass -l //192.168.0.0/share

• Export the CMC XML configuration to an NFS shareracadm get -f file.xml -t xml -l 192.168.0.0:/myshare

getactiveerrors

Table 22. Details of getactiveerrors attribute

Description Displays CMC active errors.

Synopsis • racadm getactiveerrors• racadm getactiveerrors [-s <severity>] [-m <module>]

Input The command racadm getactiveerrors displays the critical, warning, and informational messages for all the

modules. The values are:

-s <severity> — Specifies the severity type message displayed. The command racadm getactiveerrors displays the selected type of messages for all the modules. When used with -m option, only selected message type for that module is displayed. The values for -s <severity> are:

• critical• warning• info

-m <module> — Specifies the module for which the messages such as critical, noncritical (warning), and informational are displayed. The command racadm getactiveerrors displays critical, noncritical (warning), and

RACADM Subcommand Details 31

Page 32: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

informational messages for the selected module. When used with -s option, only selected message type for the module is displayed. The values for -m <module> are:

• server-<n> — where n=1–16

• server-<nx> — where n=1–8; x = a, b, c, d (lower case)

• switch-<n> — where n=1–6

• cmc-<n> — where n=1, 2

• fan-<n> — where n=1–9

• ps-<n> — where n=1–6

• chassis• kvm• lcd

NOTE: A few of the informational messages are applicable for more than one module. To avoid repetition of the same message for different modules, only one such informational message is displayed for the default command racadm getactiveerrors. When an -m option is used on another server or switch,

the informational message is displayed, if applicable.

After you run this command, the full-height, half-height, and the quarter-height servers and switches are automatically checked for informational messages (in the same order as mentioned here).

Examples • To display the entire log (Critical, Warning and Informational messages) for all modules.racadm getactiveerrors

Module ID = 1Severity = CriticalMessage = The storage battery has failed.

Module ID = 10Severity = CriticalMessage = General failure after video.

Module ID = ps-6Severity = CriticalMessage = The power input for power supply 6 is lost.

• To display the Critical error messages for all the components.racadm getactiveerrors –s critical

Module ID = 1Severity = CriticalMessage = The storage battery has failed.

Module ID = 10Severity = CriticalMessage = General failure after video.

Module ID = ps-6Severity = CriticalMessage = The power input for power supply 6 is lost.

• To display critical error messages for server–1.racadm getactiveerrors –s critical –m server-1Module ID = 1Severity = CriticalMessage = The storage battery has failed.

• The error message displayed for invalid syntax.racadm getactiveerrors –z cmc-1 ERROR: The syntax of the command specified is not correct.

• The error message displayed for invalid parameter.racadm getactiveerrors –m server-80ERROR: The syntax of the command specified is not correct.

• To display entire information log.racadm getactiveerrors -s infoModule ID = 1

32 RACADM Subcommand Details

Page 33: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Severity = CriticalMessage = A fabric mismatch deteceted for mezzanine card B1.

Module ID = ps-1Severity = CriticalMessage = The power input for power supply 1 is lost.

Module ID = ps-3Severity = CriticalMessage = The power input for power supply 3 is lost.

Module ID = cmc-1Severity = NonCriticalMessage = A firmware or software incompatibilty detected between system BIOS in slot 4 and CMC.

• Display specific module log:

racadm getactiveerrors -m server-1

getarraycfg

Table 23. Details of getarraycfg attribute

Description To display the storage array properties and configuration status, run this command.

Synopsis getarraycfg -m <module> [-s]

Input • -m — The valid value for —m <module> is server–<n>, where n = 1 to 7 and 9 to 15.

• -s — Query for current storage configuration process status.

Output Array configured properties for:

• Member Name

• Member IP

• Group Name

• Group IP

• Fabric Selection

<module> configuration completed successfully.

Example • Get the configured storage array properties from server–3.racadm getarraycfg -m server-3

• Query for current storage configuration process status on server–3.racadm getarraycfg -m server-3 -s

getassettag

Table 24. Details of getassettag attribute

Description Displays the asset tag for the chassis.

To run this subcommand, you must have the CMC Login User privilege.

Synopsis racadm getassettag [-m <module>]

RACADM Subcommand Details 33

Page 34: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Input -m <module> — Specifies the module whose asset tag you want to view.

Legal value: chassis

Example • Display asset tag for chassisracadm getassettag -m chassis

• racadm getassettag chassis 78373839–33

getchassisname

Table 25. Details of getchassisname attribute

Description Displays the name of the chassis.

To run this subcommand, you must have the CMC Login User privilege.

Synopsis racadm getchassisname

Input N/A

Example racadm getchassisnameCMC-JGB6B2S

getconfig

Table 26. Details of getconfig attribute

Description Retrieves iDRAC configuration parameters individually or all iDRAC configuration groups may be retrieved and saved to a file.

NOTE: This subcommand is deprecated. For viewing the configuration objects and its values, use get subcommand. For more information, see the Integrated Dell Remote Access Controller (iDRAC8) and iDRAC7 RACADM Command Line Interface Reference Guide available at www.dell.com/support/manuals.

Synopsis racadm getconfig -f <filename>racadm getconfig -g <groupName> [-i <index>]racadm getconfig -u <username>racadm getconfig -hracadm getconfig -g <groupName> -o <objectName> [-i index]

Input • -f — The -f <filename> option directs getconfig to write the entire iDRAC configurations to a configuration file. This file can be used for batch configuration operations using the config subcommand.

NOTE: This option is supported only on remote interfaces.

• -g — The -g <groupName> or group option, is used to display the configuration for a single group. The <groupName> is the name for the group used in the racadm.cfg files. If the group is an indexed group, then use the-i option.

• -h — The -h or help option, displays a list of all available configuration groups in alphabetical order. This option is useful when you do not remember exact group names.

• -i — The -i <index> or index option, is valid only for indexed groups and is used to specify a unique group. The <index> is a decimal integer from 1 through n, where n can vary from 1 to maximum number of indexes a particular group supports. If -i <index> is not specified, then a value of 1 is assumed for groups, which are tables that have multiple entries. The -i option enters the index value and not a named value

34 RACADM Subcommand Details

Page 35: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• -o — The -o <objectname> or object option specifies the object name that is used in the query. This option is optional and can be used with the -g option.

• -u — The-u <username> or user name option, is used to display the configuration for the specified user. The <username> option is the login name for the user.

• -v — The -v option displays more information with the display of the properties and is used with the -g option.

Output The subcommand displays error message when:

• Invalid syntax, group name, object name, index, or any other invalid database members are entered.

• The RACADM CLI transport is unsuccessful.

If errors are not encountered, this subcommand displays the content of the specified configuration.

Groups Key Attributes

cfgEmailAlert cfgEmailAlertAddress

cfgLDAPRoleGroup

cfgLDAPRoleGroupDN

cfgServerInfo cfgServerBmcMacAddress

cfgStandardSchema

cfgSSADRoleGroupName

cfgTraps cfgTrapsAlertDestIPAddr

cfgUserAdmin cfgUserAdminUserName

Groups Key Attributes

cfgEmailAlert cfgEmailAlertAddress

cfgLDAPRoleGroup

cfgLDAPRoleGroupDN

cfgServerInfo cfgServerBmcMacAddress

cfgStandardSchema

cfgSSADRoleGroupName

cfgTraps cfgTrapsAlertDestIPAddr

cfgUserAdmin cfgUserAdminUserName

Example • Displays the configuration properties (objects) that are contained in the group cfgLanNetworking.

racadm getconfig -g cfgLanNetworking • Saves all group configuration objects from to myrac.cfg.

racadm getconfig -f myrac.cfg If you do not configure the following key attributes in their respective groups for a particular index, the groups are not saved in to the file. This is applicable for all the index groups.

Saves all group configuration objects from to myrac.cfg.racadm getconfig -f myrac.cfg Saves all group configuration objects from to myrac.cfg.racadm getconfig -f myrac.cfg

Table 27. Details

Groups Key Attributes

cfgEmailAlert cfgEmailAlertAddress

cfgLDAPRoleGroup cfgLDAPRoleGroupDN

RACADM Subcommand Details 35

Page 36: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Groups Key Attributes

cfgServerInfo cfgServerBmcMacAddress

cfgStandardSchema cfgSSADRoleGroupName

cfgTraps cfgTrapsAlertDestIPAddr

cfgUserAdmin cfgUserAdminUserName

• Displays a list of the available configuration groups on in an alphabetical order.racadm getconfig -h

• Displays the configuration properties for the user named root.racadm getconfig -u root

• Displays the user group instance at index 2 with verbose information for the property values.racadm getconfig -g cfgUserAdmin -i 2 -v

• Displays an entire group of serial configuration.racadm getconfig -g cfgSerial

• Displays a single object from a particular group.racadm getconfig -g cfgSerial -o cfgSerialBaudRate

• Displays an indexed group.racadm getconfig -g cfgUserAdmin -o cfgUserAdminUserName -i 2

• Displays the current Enhanced Cooling Mode property configuration.racadm getconfig –g cfgThermal

getdcinfo

Table 28. Details of getdcinfo attribute

Description Displays general I/O module and daughter card configuration information. Only the CMC controls daughter cards.

To run this subcommand, you must have the CMC Login User privilege.

NOTE: Fabric verification for server DCs is performed only when the chassis is turned on. When the chassis is on standby power, iDRACs on the server modules remain turned off and thus are unable to report the server's DC fabric type. The DC fabric type may not be reported in the CMC user interface until iDRAC on the server is turned on.

Synopsis • racadm getdcinfo• racadm getdcinfo [-n]

Input -n — Displays the model names for the daughter cards in servers.

Table 29. Example 1

<IO#> <Type> <State> <Role>

switch-1 Gigabit Ethernet OK Master

switch-2 None N/A N/A

switch-3 Gigabit Ethernet OK Master

switch-4 None N/A N/A

switch-5 Gigabit Ethernet OK Member

36 RACADM Subcommand Details

Page 37: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

switch-6 None N/A N/A

Table 30. Example 2

<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>

server-1 Present None N/A None N/A

server-2 Not Present None N/A None N/A

server-3 Not Present None N/A None N/A

server-4 Present None N/A Gigabit Ethernet

OK

server-5 Not Present None N/A None N/A

server-6 Not Present None N/A None N/A

server-7 Not Present None N/A None N/A

server-8 Present FibreChannel 4 Invalid None N/A

server-9 Extension(1) None N/A None N/A

server-10 Not Present None N/A None N/A

server-11 Not Present None N/A None N/A

server-12 Not Present None N/A None N/A

server-13 Not Present None N/A None N/A

server-14 Not Present None N/A None N/A

server-15 Not Present None N/A None N/A

server-16 Not Present None N/A None N/A

Table 31. Display the model names for the daughter cards in servers:

<Server#> <Presence> <DC1 Model Name> <DC2 Model Name>

server-1 Present None None

server-2 Not Present None None

server-3 Not Present None None

server-4 Present None Broadcom M5708t

server-5 Not Present None None

server-6 Not Present None None

server-7 Not Present None None

server-8 Present LPe1105-M4 None

server-9 Extension(1) None None

server-10 Not Present None None

RACADM Subcommand Details 37

Page 38: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

server-11 Not Present None None

server-12 Not Present None None

server-13 Not Present None None

server-14 Not Present None None

server-15 Not Present None None

server-16 Not Present None None

getflexaddr

Table 32. Details of getflexaddr attribute

Description Displays enabled or disabled status for the entire chassis and fabric ID decoder. If used with the -i option, the command displays MACs/WWN addresses on a per slot basis.

The decoder values indicate the protocols of the network cards:

• 0 — Unsupported

• 1 — ISCSI

• 2 — FCoE-FIP

• 3 — iSCSI/FCoE-FIP

To run this subcommand, you must have the CMC Login User privilege.

NOTE: If FlexAddress is not activated on the chassis, the command displays server-assigned MAC/WWN addresses. If the slot is empty, the command enters blank in the server-assigned MAC/WWN addresses. If an external console controls the MAC/WWN addresses, the command displays an externally managed message.

Synopsis racadm getflexaddr [-i <slotNum>]

Input -i <slotNum> — Specifies the slot information that must be displayed. <slotNum> can be from 1 to 16.

Output None

Table 33. Example

<Slot#> <Status> <Server Presence>

1 Enabled Present

2 Enabled Present

3 Enabled Not Present

4 Enabled Not Present

5 Enabled Present

6 Enabled Not Present

7 Enabled Not Present

8 Enabled Not Present

9 Enabled Not Present

38 RACADM Subcommand Details

Page 39: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

10 Enabled Extension(2)

11 Enabled Not Present

12 Enabled Not Present

13 Enabled Extension(5)

14 Enabled Not Present

15 Enabled Not Present

16 Enabled Not Present

Table 34. For Fabric type

<Fabric> <Type> <Status>

A Gigabit Ethernet Enabled

B None Enabled

C None Enabled

Table 35. For Slot 9

<Fabric> <Type> <Server-Assigned> <Chassis-Assigned>

slot9-idrac Controller 18:A9:9B:FD:C1:C9 F8:BC:12:E5:FE:98(active)

slot9-A1 10 GbE KR 00:90:FA:51:2E:22

F8:BC:12:E5:FE:99(active)

10 GbE KR/3 00:90:FA:51:2E:23

F8:BC:12:E5:FE:9B(active)

FCoE-WWN 10:00:00:90:FA:51:2E:23 20:01:F8:BC:12:E5:FE:9B(active)

slot9-A2 10 GbE KR 00:90:FA:51:2E:2A F8:BC:12:E5:FE:9A(active)

slot9-B1 Gigabit Ethernet A0:36:9F:12:3D:38 F8:BC:12:E5:FE:9D(active)

NOTE:

10 GbE KR/3— The value 3 indicates that the fabric is iSCSI/FCoE-FIP.

getfanreqinfo

Table 36. Details of getfanreqinfo attribute

Description Displays fan speed request for servers and switches in percent (%).

To run this subcommand, you must have the CMC Login User privilege.

Synopsis racadm getfanreqinfo

RACADM Subcommand Details 39

Page 40: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Input N/A

Output None

Table 37. Example

<Slot#> <Server Name> <Blade Type> <Power State> <Presence> <Fan Request%>

1 SLOT-01 N/A N/A Not Present N/A

2 WIN-JGKC47ACGKG PowerEdge M630 ON Present 38

3 WIN-N24BRAT3L1J PowerEdge M630 ON Present 38

4 SLOT-04 PowerEdge M630 ON Present 17

5a nodea.NOBLEEST.COM PowerEdgeM420 ON Present 43

5b SLOT-05b PowerEdgeM420 ON Present 43

5c WIN-UMJ7OP4BIN3 PowerEdgeM420 ON Present 100

5d SLOT-05d PowerEdge M420 ON Present 43

6 SLOT-6 PowerEdge M820 ON Present 27

7 SLOT-7 PS-M4110 N/A Present 58

8 SLOT-8 N/A Extension(7) N/A N/A

9 SLOT-9 N/A Present 0

10 SLOT-10 N/A Present 0

11 SLOT-11 ON Present 38

12 SLOT-12 N/A Extension(4) N/A N/A

13 SLOT-13 N/A Extension(5) N/A N/A

14 SLOT-14 N/A Extension(6) N/A N/A

15 SLOT-15 PowerEdge M630 ON Present 38

16 SLOT-16 N/A N/A Present N/A

Switch Module Fan Request Table

Table 38. Switch Module Fan Request Table

<IO> <Name> <Type> <Presence> <Fan Request%>

Switch-1 PowerEdge M I/O Aggregator

10 GbE KR Present 30

Switch-2 PowerEdge M I/O Aggregator

10 GbE KR Present 30

Switch-3 MXL 10/40GbE 10 GbE KR Present 30

Switch-4 N/A None Not Present N/A

40 RACADM Subcommand Details

Page 41: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Switch-5 N/A None Not Present N/A

Switch-6 N/A None Not Present N/A

[Enhanced Cooling Mode]Enhanced Cooling Mode(ECM) Status = Disabled

getioinfo

Table 39. Details of getioinfo attribute

Description Displays general information about the I/O modules on the chassis.

To run this subcommand, you must have the CMC Login User privilege.

NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fibre Channel, and InfiniBand.

Synopsis • racadm getioinfo [-m <module>] [-s]• racadm getioinfo -o• racadm getioinfo -m switch-<n> -o

Input • -m <module> — Specifies the module or device.<module> must be switch — <n>, where n = 1–6

• -s — Displays stack information.

• -o — Displays IOA Flex module information. The possible values for the flex module type are:

– 0 — 4x10G Base-T FlexIO Module– 1 — 4x10G SFP+ FlexIO Module– 2 — 2x40G QSFP+ FlexIO Module– 3 — 4xFC FlexIO Module– 4 — No flex module installed– >4 — Invalid

Example

•Table 40. racadm getioinfo

<IO> <Name> <Type> <Presence> <POST> <Power> <Role> <SecureMode> <Mode>

switch-1

MXL 10/40GbE

10 GbE KR Present OK ON Master No Full Switch

switch-2

PowerEdge M I/O Aggregator

10 GbE KR Present OK ON Standalone No Standalo

ne

switch-3

Brocade M6505

Fibre Channel 16

Present OK ON MasterNo Standalo

ne

switch-4

Brocade M6505

Fibre Channel 16

Present OK ON MasterNo Standalo

ne

switch-5

PowerEdge M I/O

10 GbE KR Present OK ON Standalone No Standalo

ne

RACADM Subcommand Details 41

Page 42: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Aggregator

switch-6

MXL 10/40GbE

10 GbE KR Present OK ON Master No Full Switch

•Table 41. racadm getioinfo -s

<Chassis> <IO> <Slot> <Presence> <Role> <Unit> <Stack ID>

abc1234 Switch-1 A1 Present Master N/A N/A

abc1234 Switch-2 A2 Present Standalone 1 N/A

abc1234 Switch-3 B1 Present Master N/A N/A

abc1234 Switch-4 B2 Present Master N/A N/A

abc1234 Switch-5 C1 Present Standalone 0 N/A

abc1234 Switch-6 C2 Present Master N/A N/A

•Table 42. racadm getioinfo -m switch-1

<IO> <Name> <Type> <Presence> <POST> <Power> <Role> <Secure Mode>

<Mode>

Switch-1

MXL 10/40GbE

10 GbE KR

Present OK ON Master <No> <Full Switch>

•Table 43. racadm getioinfo -o

<IO> <Module> <Module Type>

Swtich-1 Optional Module 1Optional Module 2

N/AN/A

Switch-2 Optional Module 1Optional Module 2

4x10G Base-T FlexIO Module2x40G QSFP+ FlexIO Module

Switch-3 Optional Module 1Optional Module 2

N/AN/A

Switch-4 Optional Module 1Optional Module 2

N/AN/A

Switch-5 Optional Module 1Optional Module 2

4x10G Base-T FlexIO ModuleFlexIO Module Absent

Switch-6 Optional Module 1Optional Module 2

N/AN/A

•Table 44. racadm getioinfo -m switch-4 -o

<IO> <Module> <Module Type>

Switch-4 Optional Module 1Optional Module 2

N/AN/A

42 RACADM Subcommand Details

Page 43: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

getkvminfo

Table 45. Details of getkvminfo attribute

Description Displays KVM module information.

To run this subcommand, you must have the CMC Login User privilege.

Synopsis racadm getkvminfo

Input N/A

Table 46. Example

<module> <presence> <model> <FW Version> <status>

KVM Present Avocent iKVM Switch

00.05.00.04 Ready

getled

Table 47. Details of getled attribute

Description Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).

To run this subcommand, you must have the Login User privilege.

Synopsis racadm getled -m <module>

Input —m <module> can be one of the following:

• server-<n> where n=1–16

• server-<nx> where n=1–8; x=a, b, c, d (lower case)

• switch-<n> where n=1–6

• chassis

• cmc-active

Output • LED is blinking

• LED is not-blinking

Example • racadm getled -m server-10<module> <LED state>

server-10 Blinking

• racadm getled -m chassis <module> <LED state>

server-10 Not blinking

• racadm getled -m server-1<module> <LED state>

server-1 ON

• racadm getled -m server-9<module> <LED state>

RACADM Subcommand Details 43

Page 44: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

server-9 Extension(1)

getmacaddress

Table 48. Details of getmacaddress attribute

Description Displays the MAC/WWN addresses and fabric ID decoder for all modules or for a specified module.

The decoder values indicate the protocols of the network cards:

• 0 — Unsupported

• 1 — ISCSI

• 2 — FCoE-FIP

• 3 — iSCSI/FCoE-FIP

To use this subcommand, you must have the CMC Login User privilege.

Synopsis• racadm getmacaddress• racadm getmacaddress -m chassis• racadm getmacaddress -m switch-<n>• racadm getmacaddress [-m <module> [-x]] [-t iscsi]• racadm getmacaddress [-a]• racadm getmacaddress -c IO-Identity• racadm getmacaddress -c Flexaddress• racadm getmacaddress -c Factory• racadm getmacaddress -c all

Input• -m <module> — Specifies the module whose MAC address you want to view.

<module> may be one of the following:

server-<n>, where n=1–16

server-<nx>, where n=1–8; x=a,b,c,d (lower case)

switch-<n>, where n=1–6

• -t — Displays the iSCSI MAC addresses for all servers or the specified server if used with -m option.

• -x — Displays the extra MACs (Ethernet or iSCSI) for servers with additional LOM MACs and must be used with -m option.

• -a — Displays the Ethernet and iSCSI MAC/WWN addresses for all iDRAC or LOMs or mezzanine cards. When FlexAddress is enabled for a particular slot, then the chassis-assigned MAC/WWN address is displayed.

• -c — Displays the ethernet and iSCSI MAC/WWN and assignment type, partition status of all LOMs or mezzanine cards. The -c option must be one of the following values:

– IO-Identity — Displays the user-defined MAC/WWN addresses.

– FlexAddress — Displays the chassis-assigned MAC/WWN addresses.

– Factory — Displays factory MAC/WWN addresses.

– all — Displays Ethernet and iSCSI MAC/WWN address, Assignment Type, and Partition Status of all LOMs or mezzanine cards.

NOTE: If the chassis is powered off owing to AC loss, the output is displayed Reserved, when you try

viewing MAC addresses using the IO-Identity and -c options.

Example

• Display MACs for all modules.

racadm getmacaddress

44 RACADM Subcommand Details

Page 45: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• Display iSCSI MAC addresses for all servers.

racadm getmacaddress -t iscsi• Display iSCSI MAC for server-1.

racadm getmacaddress -m server-1 -t iscsi• Display extra iSCSI MACs for server-1 (if available).

racadm getmacaddress -m server-1 -t iscsi -x• Display the user-defined MAC and WWN address.

– racadm getmacaddress -c io-identity – racadm getmacaddress -c io-identity -m server -x

• Displays the console assigned MAC/WWN of all LOMs or mezzanine cards.

racadm getmacaddress -c all • Displays the chassis-assigned WWN/MAC address.

racadm getmacaddress -c flexaddress• Displays the MAC/WWN addresses for all LOMs or mezzanine cards.

racadm getmacaddress -c factory

Table 49. Displays the MAC address for chassis.

<Name> <Presence> <BMC MAC Address> <NIC1 MAC Address> <NIC2 MAC Address>

CMC Present N/A F0:4D:A2:77:71:72 N/A

Table 50. Displays the MAC address for chassis.

<Name> <Presence> <BMC MAC Address> <NIC1 MAC Address> <NIC2 MAC Address>

Switch-1 Present Not Installed 00:00:00:00:00:00 Not Installed

Table 51. Display MAC for server-1.

<Name> <Presence> <BMC MAC Address> <NIC1 MAC Address> <NIC2 MAC Address>

server-1 Present 00:11:43:FD:B7:2A 00:11:43:FD:B7:2A 00:11:43:FD:B7:2B

server-4 Extension(1) N/A 00:11:43:FD:B7:2C 00:11:43:FD:B7:2D

Table 52. Display extra MACs for server-1 (if available).

<Name> <Presence> <BMC MAC Address> <NIC1 MAC Address> <NIC2 MAC Address>

server-1 Present 00:11:43:FD:B7:2A 00:11:43:FD:B7:2A 00:11:43:FD:B7:2B

00:11:43:FD:B7:2C 00:11:43:FD:B7:2D

Table 53. Displays the MAC address.

<Name> <Presence> <BMC MAC Address> <NIC1 MAC Address> <NIC2 MAC Address>

CMC Present N/A 00:1E:4F:1F:3C:58 N/A

Server-1 Present 00:1E:4F:2A:AF:7B 00:1E:4F:2A:D3:97 00:1E:4F:2A:D3:99

Server-2 Present 00:22:19:D2:1E:84 N/A N/A

RACADM Subcommand Details 45

Page 46: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Server-3 Not Present N/A N/A N/A

Server-4 Present 00:18:8B:FF:45:2A 00:18:8B:FF:AA:02 00:18:8B:FF:AA:04

Switch-1 Present N/A 00:00:00:00:00:00 N/A

Table 54. Displays the Ethernet and iSCSI MAC/WWN addresses for all iDRAC or LOMs or mezzanine cards.

<Name> <Type> <Presence> <BMC MAC Address>

<NIC1 MAC Address>

<NIC2 MAC Address>

CMC N/A Present N/A 00:1E:4F:1F:3C:58

N/A

Server-1-A Gigabit Ethernet

Present 00:1E:4F:2A:AF:7B

00:1E:4F:2A:D3:97

00:1E:4F:2A:D3:99

iSCSI Present 00:1E:4F:2A:D3:98

00:1E:4F:2A:D3:9A

Server-1-B Gigabit Ethernet

Present Not Installed Not Installed

iSCSI Present Not Installed Not Installed

Server-1-C Fibre Channel 4 Present Not Installed Not Installed

Server-2-A Gigabit Ethernet

Present 00:22:19:D2:1E:84

N/A N/A

iSCSI Present N/A N/A

Server-2-B Gigabit Ethernet

Present Not Installed Not Installed

iSCSI Present Not Installed Not Installed

Server-2-C Fibre Channel 4 Present Not Installed Not Installed

Server-3 N/A Not Present N/A N/A N/A

Server-4-A Gigabit Ethernet

Present 00:18:8B:FF:45:2A

00:18:8B:FF:AA:02

00:18:8B:FF:AA:04

iSCSI Present 00:18:8B:FF:AA:03

00:18:8B:FF:AA:05

Server-4-B Gigabit Ethernet

Not Present Not Installed Not Installed

iSCSI Present Not Installed Not Installed

Server-4-C Fibre Channel 4 Present Not Installed Not Installed

Switch-1 None Present N/A 00:00:00:00:00:00

N/A

46 RACADM Subcommand Details

Page 47: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Table 55. Displays the user-defined MAC and WWN address.

<Name> <Type> <Presence> <Active WWN/MAC> <Partition Status>

<Assignment Type>

server-4-A IDRAC-Controller

Present 00:22:19:D2:21:F5

N/A Factory

Gigabit Ethernet

Present 84:2B:2B:1B:3D:F6

Unknown IO-Identity

iSCSI Present 84:2B:2B:1B:3D:F9

Unknown IO-Identity

Table 56. Displays the MAC/WWN addresses for all LOMs or mezzanine cards.

<Name> <Type> <Presence> <Active WWN/MAC>

<Partition Status>

<Assignment Type>

Server-7-A IDRAC-Controller

Present 84:8F:69:D8:B1:BD

N/A Factory

10 GbE KR/3 Present 00:90:FA:51:34:F5

Unknown Factory

10 GbE KR/3 Present 00:90:FA:51:34:FD

Unknown Factory

Switch-1 10 GbE KR Present 00:1E:C9:F1:04:94

N/A Factory

Switch-5 10 GbE KR Present 00:00:00:00:00:00

N/A Factory

NOTE:

10 GbE KR/3— The value 3 indicates that the fabric is iSCSI/FCoE-FIP.

Table 57. Displays the chassis-assigned WWN/MAC address.

<Name> <Type> <Presence> <Active WWN/MAC>

<Partition Status>

<Assignment Type>

Server-16-A

IDRAC-Controller

Present F8:DB:88:3D:6F:43

N/A FlexAddress

10 GbE KR Present F8:DB:88:3D:6F:44

Disabled FlexAddress

FCoE-FIP Present F8:DB:88:3D:6F:46

Disabled FlexAddress

Server-16-B 10 GbE KR Present F8:DB:88:3D:6F:49

Unknown FlexAddress

Server-16-C 10 GbE KR Present F8:DB:88:3D:6F:4D

Unknown FlexAddress

RACADM Subcommand Details 47

Page 48: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Table 58. Displays Ethernet and iSCSI MAC/WWN address, Assignment Type, and Partition Status of all LOMs or mezzanine cards.

<Name> <Type> <Presence> <Active WWN/MAC> <Partition Status>

<Assignment Type>

CMC N/A Present 34:17:EB:E6:E0:24

N/A Factory

server-1-A 10 GbE KR Not Installed 10:98:36:AC:70:EB

Not Installed Not Installed

Server-2 Not Installed Not Present Not Installed Not Installed Not Installed

Server-3-A Reserved Present

Switch-4 Not Installed Not Present Not Installed Not Installed Not Installed

Switch-1 Not Installed Not Present Not Installed N/A N/A

NOTE: If the I/O Modules in slots 1 and 2 are absent and the getmacaddress -a and getmacaddress —c all commands

are run, the output is displayed as Not Installed in the following columns:

• <Presence>• <NIC1 MAC Address>• <NIC2 MAC Address>

getmodinfo

Table 59. Details of getmodinfo attribute

Description Displays configuration and status information for all modules or a specified module (server, switch, CMC, fan unit, power supply unit (PSU), KVM, or I2C cable) in the chassis.

A power state of "Primary" denotes Active CMC.

To run this subcommand, you must have the CMC Login User privilege.

NOTE: The Service tag field is blank for modules that do not have service tag.

Synopsis racadm getmodinfo [-m <module>] [-A]

Input • -m <module> — Specifies the module whose configuration and status information you want to view. The default command (no options) displays information about all major components in the chassis.<module> may be any of the following values:

– server-<n> where n=1–16

– server-<nx> where n=1–8; x = a, b, c, d

– switch-<n> where n=1–6

– cmc-<n> where n=1–2

– fan-<n> where n=1–9

– ps-<n> where n=1–6

– chassis

– kvm

– io-cable

– fpc-cable

• -A — Suppresses headers or labels in the output.

Examples

48 RACADM Subcommand Details

Page 49: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Display status of all the modules in the chassis

racadm getmodinfo

Display status of fan module 3 in the chassis

racadm getmodinfo -m fan-3

•Table 60. Details of racadm getmodinfo -m switch-1

<module> <presence> <pwrState> <health> <svcTag> <nodeId>

Switch-1 Present ON OK 0000000 N/A•

Table 61. Details of racadm getmodinfo

<module> <presence> <pwrState> <health> <svcTag> <nodeId>

Chassis Present ON Not OK noble01 N/AFan-1 Present ON OK N/A N/AFan-2 Present ON OK N/A N/AFan-3 Present ON OK N/A N/AFan-4 Present ON OK N/A N/AFan-5 Present ON OK N/A N/AFan-6 Present ON OK N/A N/AFan-7 Present ON OK N/A N/AFan-8 Present ON OK N/A N/AFan-9 Present ON OK N/A N/APS-1 Present Online OK N/A N/APS-2 Present Online OK N/A N/APS-3 Present Online OK N/A N/APS-4 Present Online OK N/A N/APS-5 Present Online OK N/A N/APS-6 Present Failed Not OK N/A N/ACMC-1 Present Primary OK N/A N/ACMC-2 Present Standby OK N/A N/ASwitch-1 Present ON OK 0000000 N/ASwitch-2 Not Present N/A N/A N/A N/ASwitch-3 Present ON OK 2XVRTS1 N/ASwitch-4 Present ON OK 000000 N/ASwitch-5 Present ON OK N/A N/ASwitch-6 Not Present N/A N/A N/A N/AServer-1 Present ON OK ABC1234 ABC1234Server-2 Present ON OK ABC1234 ABC1234Server-3 Present ON OK BCD1234 BCD1234Server-4 Present ON OK BCD1234 BCD1234Server-5 Present ON OK BCD1234 BCD1234Server-6 Present ON OK BCD1234 BCD1234

RACADM Subcommand Details 49

Page 50: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Server-7 Present ON OK BCD1234 BCD1234Server-8 Present ON OK BCD1234 BCD1234Server-9 Present ON OK BCD1234 BCD1234Server-10 Present ON OK ABC1234 ABC1234Server-11 Present ON OK ABC1234 ABC1234Server-12 Present ON OK BCD1234 BCD1234Server-13 Present ON OK BCD1234 BCD1234Server-14 Present ON OK ABC1234 ABC1234Server-15 Present ON OK BCD1234 BCD1234Server-16 Present ON OK BCD1234 BCD1234KVM Present ON OK N/A N/AIO-Cable Present ON OK noble01 N/AFPC-Cable Present ON OK noble01 N/A

NOTE: A power state of "Primary" denotes Active CMC.

getniccfg

Table 62. Details of getniccfg attribute

Description Displays the current NIC settings.

Synopsis racadm getniccfg [-m <module>]

Input –m <module> must be one of the following values:

• chassis : Default state if -m is not specified.

• server-<n> : where n=1–16

• server-<nx> : where n=1–8; x = a, b, c, d (lower case)

• switch-<n> : where n=1–6

50 RACADM Subcommand Details

Page 51: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Output NOTE:

Table 63. Output

IPv4 settings:NIC Enabled =1IPv4 Enabled =1DHCP Enabled =1IP Address =10.94.225.165Subnet Mask =255.255.255.128Gateway =10.94.225.129IPv6 settings:IPv6 Enabled =1DHCP6 Enabled =0IP Address 1 =2000:de11:bcd1:fc14:1234:5678:2468:abcdGateway =::Link Local Address =fe80::f21f:afff:fed0:82d6/64IP Address 2 =::IP Address 3 =::IP Address 4 =::IP Address 5 =::IP Address 6 =::IP Address 7 =::IP Address 8 =::IP Address 9 =::IP Address 10 =::IP Address 11 =::IP Address 12 =::IP Address 13 =::IP Address 14 =::IP Address 15 =::LOM Status:NIC Selection =dedicatedLink Detected =YesSpeed =1Gb/sDuplex Mode =Full DuplexActive NIC =DedicatedStatic IPv4 settings:Static IP Address =192.168.0.120Static Subnet Mask =255.255.255.0Static Gateway =192.168.0.1Static IPv6 settings:Static IP Address 1 =2000:de11:bcd1:fc14:1234:5678:2468:abcd/64Static Prefix Length =64Static Gateway =::

IPv6 information is displayed only if IPv6 is enabled in iDRAC.

RACADM Subcommand Details 51

Page 52: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: IPv6 Address 1 field indicates static IP and IPv6 Address 2 field indicates dynamic IP.

Example • Display CMC network settingsracadm getniccfg -m chassis

getpbinfo

Table 64. Details of getpbinfo attribute

Description Displays power budget status information.

To run this subcommand, you must have the CMC Login User privilege.

Synopsis racadm getpbinfo

Input N/A

Table 65. Example

System Input Power = 1574 WPeak System Power = 1916 WPeak System Power Timestamp = 09:29:20 11/26/2014Minimum System Power = 374 WMinimum System Power Timestamp = 09:20:51 11/26/2014Overall Power Health = OKRedundancy = NoSystem Input Power Cap = 16685 WRedundancy Policy = NoneDynamic PSU Engagement Enabled = NoSystem Input Max Power Capacity = 16685 WInput Redundancy Reserve = 0 WInput Power Allocated to Servers = 1826 WInput Power Allocated to Chassis Infrastructure

= 1212 W

Total Input Power Available for Allocation

= 13648 W

Standby Input Power Capacity = 0 WServer Based Power Management Mode = NoMax Power Conservation Mode = NoServer Performance Over Power Redundancy = NoPower Available for Server Power-on = 13648 WExtended Power Performance (EPP) Status = DisabledAvailable Power in EPP Pool = 0 W (0 BTU/h)

52 RACADM Subcommand Details

Page 53: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Used Power in EPP Pool = 0 W (0 BTU/h)EPP Percent - Available = 0.0

Table 66. Chassis Power Supply Status Table

<Name> <Model> <Power State> <Input Current>

<Input Volts> <Output Rated Power>

PS1 08V4DK Online 1.0 A 240.0 V 3000 WPS2 08V4DK Online 1.9 A 239.2 V 3000 WPS3 08V4DK Online 1.1 A 239.5 V 3000 WPS4 08V4DK Online 1.1 A 239.5 V 3000 WPS5 08V4DK Online 1.0 A 239.8 V 3000 WPS6 08V4DK Online 1.9 A 239.8 V 3000 W

Table 67. Server Module Power Allocation Table

<Slot#> <Server Name> <PowerState> <Allocation> <Priority>

<Blade Type>

1 SLOT-01 ON 114 W 1 PowerEdge M6302 WIN-JGKC47ACGKG ON 77 W 1 PowerEdge M6303 SLOT-03 ON 93 W 1 PowerEdge M6304 SLOT-04 ON 137 W 1 PowerEdge M6305 SLOT-05 ON 129 W 1 PowerEdge M6306 SLOT-06 ON 130 W 1 PowerEdge M6307 SLOT-07 ON 120 W 1 PowerEdge M6308 WIN-HP4N5G1EOCS ON 104 W 1 PowerEdge M6309 WIN-HP4N5G1EOCS ON 116 W 1 PowerEdge M63010 SLOT-10 ON 127 W 1 PowerEdge M63011 SLOT-11 ON 110 W 1 PowerEdge M63012 SLOT-12 ON 118 W 1 PowerEdge M63013 SLOT-13 ON 106 W 1 PowerEdge M63014 SLOT-14 ON 96 W 1 PowerEdge M63015 SLOT-15 ON 115 W 1 PowerEdge M63016 SLOT-16 ON 134 W 1 PowerEdge M630

NOTE: Extended Power Performance (EPP) – related fields are displayed even if EPP is disabled.

getpminfo

Table 68. Details of getpminfo attribute

Description Displays power management status information.

RACADM Subcommand Details 53

Page 54: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

To run this subcommand, you must have the CMC Login User privilege.

Synopsis racadm getpminfo

Input N/A

Table 69. Example:

[Real-Time Power Statistics]System Input Power = 1661 W (5667 BTU/h)Peak System Power = 1916 W (6537 BTU/h)Peak System Power Start Time = 09:19:27 11/26/2014Peak System Power Timestamp = 09:29:20 11/26/2014Minimum System Power = 35 W (119 BTU/h)Minimum System Power Start Time = 09:19:27 11/26/2014Minimum System Power Timestamp = 09:54:00 11/26/2014System Idle Power = 1661 W (5667 BTU/h)System Potential Power = 3414 W (11649 BTU/h)System Input Current Reading = 7.3 A

[Real-Time Energy Statistics]System Energy Consumption = 1.6 kWhSystem Energy Consumption Start Time = 09:19:27 11/26/2014System Energy Consumption Timestamp = 10:31:42 11/26/2014

[System Power Status]Chassis Power State = ONOverall Power Health = OKRedundancy = No

[System Power Policy Configuration]System Input Power Cap = 16685 W (56931 BTU/h | 100%)Redundancy Policy = NoneDynamic PSU Engagement Enabled = No

[Power Budgeting]System Input Max Power Capacity = 16685 WInput Redundancy Reserve = 0 WInput Power Allocated to Servers = 1875 WInput Power Allocated to Chassis Infrastructure = 1402 WTotal Input Power Available for Allocation = 13408 WStandby Input Power Capacity = 0 W

54 RACADM Subcommand Details

Page 55: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

getraclog

Table 70. Details of getraclog attribute

Description The getraclog command displays CMC log entries.

Synopsis • racadm getraclog [-i]• racadm getraclog [-s <start>] [-c <count>] [--more]

NOTE: If options are not provided, the entire log is displayed.

Input • -c — Specifies the number of records to display.

NOTE: On Remote RACADM, the number of logs are restricted to 25 by default.

• -i — Displays the number of entries in the CMC log.

• --more — Displays one screen at a time and prompts you to continue (similar to the UNIX more command).

• -s — Specifies the starting record used for the display.

NOTE: When Enhanced Chassis Logging and Events feature is enabled, then -i and --more options are not displayed.

Example • Display the starting record and the number of records.racadm getraclog -s 10 -c 2

• Display a few records and prompt to display another set of records.$ racadm getraclog --moreDec 4 22:23:09 CMC-JP4BF2S Login success from 192.168.0 (username=root, type=SSH, sid=16393)Dec 4 22:24:54 CMC-JP4BF2S Login success from 192.168.0 (username=test, type=SSH, sid=35885)Dec 4 22:26:20 CMC-JP4BF2S Login success from 192.168.0 (username=root, type=GUI, sid=27476)Dec 4 22:28:06 CMC-JP4BF2S Mod password of user puser succeedsDec 4 22:28:06 CMC-JP4BF2S Mod privileges of user puser succeedsDec 4 22:28:21 CMC-JP4BF2S Login success from 192.168.0 (username=puser, type=SSH, sid=39229)Dec 4 22:29:12 CMC-JP4BF2S Mod password of user nuser succeedsDec 4 22:29:12 CMC-JP4BF2S Mod privileges of user nuser succeedsDec 4 22:29:51 CMC-JP4BF2S SSH login failed (username=nuser, ip=192.168.0, reason=Local user fails to login )Dec 4 22:30:23 CMC-JP4BF2S last message repeated 3 timesDec 4 22:30:23 CMC-JP4BF2S Mod privileges of user nuser succeedsDec 4 22:30:38 CMC-JP4BF2S SSH login failed (username=nuser, ip=192.168.0, reason=Local user fails to login )[more]

• Entry in the RAC log when Extended Power Performance control is enabled or disabled.racadm getraclogJul 31 14:16:11 CMC-4C2WXF1 Log ClearedJul 31 14:15:49 CMC-4C2WXF1 Extended Power Performance is EnabledJul 31 14:15:49 CMC-4C2WXF1 Extended Power Performance is Disabled

• When Enhanced Logging mode is enabled, the output of getraclog is displayed similar to chassislog output.Using racadm config -g cfgRacTuning -o cfgRacTuneEnhancedLog 1 command, Enhanced Logging feature is enabled.

SeqNumber = 38Message ID = USR8501Category = AuditAgentID = CMC

RACADM Subcommand Details 55

Page 56: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Severity = InformationTimestamp = 2014-10-18 15:48:10Message Arg 1 = 14503Message Arg 2 = 48186Message = Successfully closed Session process: pid=14503 sid=4818

getractime

Table 71. Details of getractime attribute

Description Displays the current CMC time.

Synopsis • racadm getractime [-d]• racadm getractime [-d] [-z]• racadm getractime [-n]

Input • -d — Displays the time in the format, YYYYMMDDhhmmss.

• -z — Displays timezone.

• -n — Displays NTP peer information.

NOTE: If the options are not provided, then the getractime subcommand displays the time in a common readable format.

Output The current CMC time is displayed.

Example • racadm getractimeMon May 13 17:17:12 2013

• racadm getractime -d20141126114423

getredundancymode

Table 72. Details of getredundancymode attribute

Description Displays the redundancy status (Redundant or Non-Redundant) of the CMC.

To run this subcommand, you must have the CMC Login User privilege.

Synopsis racadm getredundancymode

Input N/A

Example racadm getredundancymodeRedundant

getsel

Table 73. Details of getsel attribute

Description Displays all system event log (SEL) entries in CMC.

Synopsis • racadm getsel [-i] [-m <module>]

56 RACADM Subcommand Details

Page 57: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• racadm getsel [-s <start>][-c <count>] [-m <module>] [--more]

NOTE: If no arguments are specified, the entire log is displayed.

Input • —i — Displays the number of entries in the SEL.

• -s — Displays the starting record number.

• -c — Specifies the number of records to display.

• -m <module> — Must be one of the following values:

– server-<n> : where n = 1–16

– server-<nx> : where n = 1–8; x = a, b, c, d (lower case)

• --more — Displays one screen at a time and prompts the user to continue (similar to the UNIX more command.)

Example• Display entire log.

racadm getsel• Display number of records in log.

racadm getsel -i

getsensorinfo

Table 74. Details of attribute

Description Displays the status for system sensors.

To run this subcommand, you must have the login user privilege.

NOTE: General purpose graphical processing unit (GPGPU) status is displayed only on PowerEdge C4130 servers.

Synopsis • racadm getsensorinfo• racadm getsensorinfo -c

Input -c — Compact output format.

NOTE: Chassis Controller is supported only on Dell PowerEdge FX2 and GPU sensors are displayed only on PowerEdge C4130 servers.

Table 75. Example

<senType> <Num> <sensorName> <status> <reading> <units> <LC> <UC>

FanSpeed 1 Fan-1 OK 4768 rpm 2344 14500FanSpeed 2 Fan-2 OK 4873 rpm 2344 14500FanSpeed 3 Fan-3 OK 4832 rpm 2344 14500FanSpeed 4 Fan-4 OK 4704 rpm 2344 14500FanSpeed 5 Fan-5 OK 4833 rpm 2344 14500FanSpeed 6 Fan-6 OK 4829 rpm 2344 14500FanSpeed 7 Fan-7 OK 4719 rpm 2344 14500FanSpeed 8 Fan-8 NOT OK 1 rpm 2344 14500

RACADM Subcommand Details 57

Page 58: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

FanSpeed 9 Fan-9 OK 4815 rpm 2344 14500Temp 1 Ambient_Temp OK 22 celcius N/A 40

Table 76. Example

<senType> <Num> <sensorName> <status> <health>

PWR 1 PS-1 Online OKPWR 2 PS-2 Online OKPWR 3 PS-3 Online OKPWR 4 PS-4 Slot Empty N/APWR 5 PS-5 Failed OKPWR 6 PS-6 Slot Empty N/A

Table 77. Example

<senType> <Num> <sensorName> <status>

Cable 1 IO-Cable OKCable 2 FPC-Cable OK

Table 78. Sensor Type: FanSpeed

<Num> <sensorName>

<status> <reading> <LW> <LC> <UW> <UC>

1 Fan-1 OK 5515 rpm N/A 3508 N/A 90342 Fan-2 OK 5762 rpm N/A 3697 N/A 90343 Fan-3 OK 5786 rpm N/A 3697 N/A 90344 Fan-4 OK 5534 rpm N/A 3508 N/A 90345 Fan-5 OK 5789 rpm N/A 3697 N/A 90346 Fan-6 OK 5822 rpm N/A 3697 N/A 90347 Fan-7 OK 5524 rpm N/A 3508 N/A 90348 Fan-8 OK 5790 rpm N/A 3697 N/A 90349 Fan-9 OK 5790 rpm N/A 3697 N/A 9034

Table 79. Sensor Type:Temp

<Num> <sensorName> <status> <reading> <LW> <LC> <UW> <UC>1 Ambient_Temp OK 22 C N/A N/A N/A 40

Sensor Type: Power

58 RACADM Subcommand Details

Page 59: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Table 80. Details

<Num> <sensorName> <status> <health>1 PS-1 Online OK2 PS-2 Online OK3 PS-3 Online OK4 PS-4 Fail (No AC) Not OK5 PS-5 Online OK6 PS-6 Fail (No AC) Not OK

Table 81. Sensor Type: Cable

<Num> <sensorName> <status>1 IO-Cable OK2 FPC-Cable OK

getslotname

Table 82. Details of attribute

Description Displays the name of the slot in the chassis. Optionally, this command can be used to find if the slot name, host name, or iDRAC DNS name is displayed in the CMC User Interface or with the getslotname —i <slotNum> | —h command.

NOTE: If the Slot Name, Host Name, and iDRAC DNS Name exceed the character limit, the names are truncated while displaying for all the slots in the chassis

To use this subcommand, you must have the CMC Login User privilege.

Synopsis • racadm getslotname• racadm getslotname -i <slotNum>• racadm getslotname -h <enabled>

Input • racadm getslotname—Displays the slot name for all 16 slots in the chassis.

• -i <slotNum>—Displays the ID of the slot.

Legal values: 1–16

• -h <enabled>—Specifies whether to use the slot name, the host name, or the iDRAC DNS name. The following are the valid options:

– 0 = Displays slot name.

– 1 = Displays host name instead of slot name.

– 2 = Displays the iDRAC DNS name instead of slot name.

Example

• Display the name of Slot 3.

racadm getslotname -i 3• Display all slots names.

racadm getslotname• Check if Display Slot Name, Host Name, or iDRAC DNS name is active (0 = Slot Name, 1 = Host Name, 2 = iDRAC DNS name).

racadm getslotname -h

RACADM Subcommand Details 59

Page 60: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• Display iDRAC DNS Name: 2

getslotname -h<Slot #> <Slot Name> <Host name> <iDRAC DNS Name> 1 SLOT-ONEE 2 SLOT-02 3 SLOT-03 4 idrac MN12G-1.tejas.com idrac 5 SLOT-05 6 idrac- WIN-HP4N5G1EOCS idrac- 7 SLOT-07 8 SLOT-08 9 SLOT-09 10 SLOT-10 11 SLOT-11 12 SLOT-12 13 SLOT-13 14 SLOT-14 15 SLOT-15 16 SLOT-16

getssninfo

Table 83. Details of getssninfo attribute

Description Displays a list of users that are connected to CMC. The following information is displayed:

• Session ID

• Username

• IP address (if applicable)

• Session type (for example, serial or Telnet)

• Login date and time in MM/DD/YYYY HH:MM:SS format

NOTE: Based on the Session ID (SSNID) or the user name (User), the CMC administrator can close the respective sessions or all the sessions using the closessn subcommand. For more information,

see closessn.

Synopsis racadm getssninfo [-u <username> | -u *] [-A]

Input • -u — displays only sessions associated with a specific user.

• -A — does not display headers or labels.

Table 84. Example

SSNID Type User IP Address Login Date/Time

58999 SSH root 192.168.0.10 04/07/2016 12:00:34

Display the details of sessions without header

racadm getssninfo -A"43584" "SSH" "root" "192.168.0.10" "04/07/2016 12:00:34"

• Display all currently active sessions for a specific user

racadm getssninfo -u root

60 RACADM Subcommand Details

Page 61: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

getsvctag

Table 85. Details of attribute

Description Displays the service tag of the host system.

Synopsis racadm getsvctag [-m <module>]

Input -m <module> — Must be one of the following values:

• chassis• server-<n> — where n = 1–16

• server-<nx> — where n = 1–8; x = a, b, c, d (lower case)

• switch-<n> — where n = 1–6

Output Any system tag as applicable.

Example • Display Service tag of Server in Slot 1racadm getsvctag -m server-1

• Display Service tag of all the components in the chassisracadm getsvctag

getsysinfo

Table 86. Details of attribute

Description Displays information related to CMC, managed system, and watchdog configuration.

NOTE: The host name and OS Name fields in the getsysinfo output display accurate information only if the Dell OpenManage Server Administrator is installed on the managed system. Else, these fields may be blank or inaccurate. An exception to this are VMware operating system names, which are displayed even if the Server Administrator is not installed on the managed system.

Synopsis racadm getsysinfo [-d] [-A] [-c] [-4] [-6]

Input • —4 — Displays IPv4 settings

• —6 — Displays IPv6 settings

• —c — Displays common settings

• —d — Displays CMC information

• —A — Eliminates the printing of headers or labels

Output

racadm getsysinfoCMC Information:CMC Date/Time = Wed Sep 17 2014 23:13Primary CMC Location = CMC-1Primary CMC Version = 5.00Standby CMC Version = 5.00Last Firmware Updated = Tue Sep 16 2014 22:11Hardware Version = A09CMC Network Information:NIC Enabled = 1MAC Address = 78:2B:CB:46:5C:8A

RACADM Subcommand Details 61

Page 62: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Register DNS CMC Name = 1DNS CMC Name = cmc-effortCurrent DNS Domain = cmc.comVLAN ID = 1VLAN Priority = 0VLAN Enabled = 0CMC IPv4 Information:IPv4 Enabled = 1Current IP Address = 192.168.0.10Current IP Gateway = 192.168.0.10Current IP Netmask = 255.255.255.0DHCP Enabled = 1Current DNS Server 1 = 0.0.0.0Current DNS Server 2 = 0.0.0.0DNS Servers from DHCP = 0

CMC IPv6 Information:IPv6 Enabled = 0Autoconfiguration Enabled = 0Link Local Address = ::Current IPv6 Address 1 = ::Current IPv6 Gateway = ::Current IPv6 DNS Server 1 = ::Current IPv6 DNS Server 2 = ::DNS Servers from DHCPv6 = 0

Chassis Information:System Model = PowerEdge M1000eSystem AssetTag = 12345678901234567890123456781234456771234567890asvcdefrtghyhytgService Tag = JGB6B2SChassis Name = CMC-JGB6B2SChassis Location = 3rdflorChassis Midplane Version= 1.1Power Status = ON

Example

• Display Chassis information

racadm getsysinfo -c• Display CMC information

racadm getsysinfo -d• Display IPv4 details without header

racadm getsysinfo -A"CMC IPv4 Information:""1""192.168.0.10""192.168.0.10""255.255.255.0""1""192.168.0.10""0.0.0.0""1"

gettracelog

Table 87. Details of attribute

Description Displays the CMC diagnostic trace log.

Synopsis • racadm gettracelog [-i]• racadm gettracelog [-s <start>] [-c <count>] [--more]

62 RACADM Subcommand Details

Page 63: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Input • —i — Displays the number of entries in CMC trace log.

• --more — Displays one screen at a time and prompts the user to continue (similar to the UNIX more command).

• -c — Specifies the number of records to display.

• -s — Specifies the starting record to display.

Output The default output display shows the record number, timestamp, source and description. The timestamp begins at midnight, January 1 and increases until the system starts. After the system starts, the system’s timestamp is used.

Example • Display entire logracadm gettracelog

• Display number of records in logracadm gettracelog -iTotal Records: 228

getversion

Table 88. Details of getversion attribute

Description Displays the current software version, model and generation information, and whether the target device can be updated.

Synopsis

Table 89. Details

<server> <iDRAC version> <Blade Type> <Gen> <Updatable>

server-1 1.40.40 (Build 08) PowerEdge M520 iDRAC Y

server-2 3.50 (Build 2) PowerEdgeM610x iDRAC6 Y

server-4 3.50 (Build 4) PowerEdgeM710HD iDRAC6

Table 90. Details

<Server> <CPLD Version> <Blade Type>

server-1 1.0.5 PowerEdgeM520

server-2 1.0.3 PowerEdgeM610x

server-4 1.0.0 PowerEdgeM710HD

server-5 1.0.3 PowerEdgeM710

server-7 1.0.6 PowerEdgeM620

server-9 1.0.5 PowerEdgeM520

racadm getversion -l -m server-1

RACADM Subcommand Details 63

Page 64: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Table 91. Details

<Server> <Component> <Version> <Install Date>

server-1 BIOS 1.6.0 2013-01-09

iDRAC1.40.40 1.40.40 2013-01-31

USC 1.1.5.154 2013-04-16

Diagnostics 4225A2 2012-12-21

OS Drivers 7.2.0.7 2012-12-21

BIOS 1.5.2 Rollback

BP12G+ 0:1 0.16 Reinstall

iDRAC Rollback

System CPLD 1.0.5 1999-12-31

NIC-Broadcom Gigabit Ethernet BCM5720 - BC:30:5B:97:06:C4

7.6.6 Rollback

NIC-Broadcom Gigabit Ethernet BCM5720 - BC:30:5B:97:06:C4

7.6.12 Reinstall

NIC-Broadcom Gigabit Ethernet BCM5720 - BC:30:5B:97:06:C4

7.6.12 2013-04-02

NIC-Broadcom Gigabit Ethernet BCM5720 - BC:30:5B:97:06:C6

7.6.6 Rollback

NIC-Broadcom Gigabit Ethernet BCM5720 - BC:30:5B:97:06:C6

7.6.12 Reinstall

NIC-Broadcom Gigabit Ethernet BCM5720 - BC:30:5B:97:06:C6

7.6.12 2013-04-02

NIC-PERC S110 Controller

3.0.0-0139 2012-10-11

RAID-PERC H310 Mini 20.10.1-0084 Reinstall

RAID-PERC H310 Mini 20.10.1-0084 Reinstall

RAID-PERC H310 Mini 20.10.1-0084 2012-02-09

BP12G+ 0:1 0.16 1999-12-31

racadm getversion -l -m server-1 -f bios

64 RACADM Subcommand Details

Page 65: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Table 92. Details

<Server> <Component> <Version> <Install Date>

server-1 BIOS 1.6.0 2013-01-09

ifconfig

Table 93. Details of ifconfig attribute

Description Displays the contents of the network interface table.

To use this subcommand, you must have the Administrator privilege.

Synopsis racadm ifconfig

Input N/A

Table 94. Example

eth0 Link encap:Ethernet HWaddr 00:1D:09:FF:DA:23 inet addr:192.168.0.0 Bcast:192.168.0.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:2550665 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:272532097 (259.9 MiB) TX bytes:0 (0.0 B)

krbkeytabupload

Table 95. Details of krbkeytabupload attribute

Description Uploads a Kerberos keytab file to CMC.

To run this subcommand, you must have the Configure Chassis Administrator privilege.

NOTE: This subcommand is only supported on the remote interface(s).

Synopsis racadm krbkeytabupload [-f <filename>]<filename> is the name of the file including the path.

Input -f — Specifies the filename of the keytab uploaded. If the file is not specified, the keytab file in the current

directory is selected.

Example Upload a kerberos keytab file from the local filesystem:

racadm krbkeytabupload -f c:\keytab\krbkeytab.tab

netstat

Table 96. Details of netstat attribute

Description Displays the routing table and the current connections.

RACADM Subcommand Details 65

Page 66: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

To run this subcommand, you must have the Execute Diagnostic Commands permission.

Synopsis racadm netstat

Input N/A

Table 97. Output - Kernel IP routing table

Destination Gateway Genmask Flags MSS Window irtt Iface

0.0.0.0 100.101.17.1 0.0.0.0 UG 0 0 0 eth0100.101.17.0 0.0.0.0 255.255.255

.0U 0 0 0 eth0

Table 98. Output - Kernel IPv6 routing table

Destination Next Hop Flags Metric Ref Use If

2607:f2b:f088:17::/64

:: U 256 0 0 eth0

fe80::/64 :: U 256 0 0 eth0ff00::/8 :: U 256 11196 053 eth0::/0 :: U 1024 1 19 eth0

ping

Table 99. Details of ping attribute

Description Verifies if the destination IP address is reachable from CMC with the current routing-table contents. A destination IP address is required. Based on the current routing-table contents, an ICMP echo packet is sent to the destination IP address.

To run this subcommand, you must have the Administrator privilege.

Synopsis racadm ping <ipaddress>

Input <ipaddress> — The IP address of the remote endpoint to ping.

Output PING 192.168.0 (192.168.0): 56 data bytes64 bytes from 192.168.0: seq=0 ttl=64 time=4.121 ms192.168.0 ping statistics 1 packets transmitted, 1 packets received, 0 percent packet lossround-trip min/avg/max = 4.121/4.121/4.121 ms

ping6

Table 100. Details of ping6 attribute

Description Verifies if the destination IPv6 address is reachable from CMC or with the current routing-table contents. A destination IPv6 address is required. Based on the current routing-table contents, an ICMP echo packet is sent to the destination IPv6 address.

66 RACADM Subcommand Details

Page 67: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

To run this subcommand, you must have the Administrator privilege.

Synopsis racadm ping6 <ipv6address>

Input <ipv6address> — the IPv6 address of the remote endpoint to ping.

Example Pinging 2011:de11:bdc:194::31 from 2011:de11:bdc:194::101 with 32 bytes of data:Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms Reply from 2011:de11:bdc:194::31: time<1ms

Ping statistics for 2011:de11:bdc:194::31: Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms

racdump

Table 101. Details of racdump attribute

Description Provides a single command to get dump, status, and general CMC board information.

This subcommand displays the comprehensive chassis status, configuration state information, and historic event logs. Used for post deployment configuration verification and during debugging sessions.

To run this subcommand, you must have the Administrator privilege.

Racdump includes the following subsystems and aggregates the following RACADM commands:

• General System/RAC information — getsysinfo

• Session information — getssinfo

• Sensor information — getsensorinfo

• Switches information (IO Module) — getioinfo

• Mezzanine card information (Daughter card) — getdcinfo

• All modules information — getmodinfo

• Power budget information — getpbinfo

• KVM information — getkvminfo

• NIC information (CMC module) — getniccfg

• Redundancy information — getredundancymode

• Trace log information — gettracelog

• RAC event log — getraclog

• System event log — getsel

Synopsis racadm racdump

Input N/A

Output The following information is displayed when this subcommand is processed:

• General system or RAC information

• Coredump

• Session information

• Process information

• Firmware build information

RACADM Subcommand Details 67

Page 68: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example

racadm racdump=============================================================================== General System/RAC Information===============================================================================

CMC Information:CMC Date/Time = Wed, 28 Nov 2007 11:55:49 PMActive CMC Version = X08Standby CMC Version = N/ALast Firmware Update = Wed Nov 21 21:37:56 2007Hardware Version = 2Current IP Address = 192.168.0.1Current IP Gateway = 192.168.0.1Current IP Netmask = 192.168.0.1DHCP Enabled = 1MAC Address = 00:55:AB:39:10:0FCurrent DNS Server 1 = 0.0.0.0Current DNS Server 2 = 0.0.0.0DNS Servers from DHCP = 0Register DNS CMC Name = 0DNS CMC Name = cmc-servicetagCurrent DNS Domain =

Chassis Information:System Model = PowerEdgeM1000eControlPanelSystem AssetTag = 00000Service Tag =Chassis Name = Dell Rack SystemChassis Location = [UNDEFINED]Power Status = ON

=============================================================================== Session Information===============================================================================

Type User IP Address Login Date/TimeSSH root 192.168.0.2 11/28/2007 23:40:53KVM root 169.254.31.30 11/28/2007 18:44:51

=============================================================================== Sensor Information===============================================================================

<senType> <Num> <sensorName> <status> <reading> <units> <lc><uc>FanSpeed 1 Fan-1 OK 14495 rpm 7250 14500FanSpeed 2 Fan-2 OK 14505 rpm 7250 14500FanSpeed 3 Fan-3 OK 4839 rpm 2344 14500FanSpeed 4 Fan-4 OK 14527 rpm 7250 14500FanSpeed 5 Fan-5 OK 14505 rpm 7250 14500FanSpeed 6 Fan-6 OK 4835 rpm 2344 14500FanSpeed 7 Fan-7 OK 14521 rpm 7250 14500FanSpeed 8 Fan-8 Not OK 1 rpm 7250 14500FanSpeed 9 Fan-9 OK 4826 rpm 2344 14500

<senType> <Num> <sensorName> <status> <reading> <units> <lc><uc>Temp 1 Ambient_Temp OK 21 celcius N/A 40

<senType> <Num> <sensorName> <status> <AC-OK status>PWR 1 PS-1 Online OKPWR 2 PS-2 Online OKPWR 3 PS-3 Online OK

68 RACADM Subcommand Details

Page 69: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

PWR 4 PS-4 Slot Empty N/APWR 5 PS-5 Failed OKPWR 6 PS-6 Slot Empty N/A

racreset

Table 102. Details of racreset attribute

Description Resets CMC. The reset event is logged in the hardware (SEL) and CMC (RAC) logs.

To run this subcommand, you must have the Chassis Administrator privilege.

NOTE: After you run the racreset subcommand, CMC may require up to two minutes to return to a usable state.

NOTE: There is a 100 percent fan request when the command is run against the servers.

Synopsis racadm racreset [-m <module> [-f]]

Input • -m — The values must be one of the following:

– server–<n> — where n=1–16

– server–<nx> — where n=1–8; x = a, b, c, d (lower case)

NOTE:

• Multiple modules may be specified, such as -m <module1> -m <module 2>.

• -f option is used to force the reset and is available only with an -m option.

Output racadm racresetRAC reset operation initiated successfully. It may take up to a minute for the RAC to come online again.

Example • To reset CMC.racadm racreset

• To reset server 1racadm racreset -m server-1

• To reset servers 1 and 3racadm racreset -m server-1 -m server-3

racresetcfg

Table 103. Details of racresetcfg attribute

Description Deletes your current CMC configuration and resets CMC to the factory default settings. After reset, the default name and password are root and calvin, respectively, and the IP address is 192.168.0.120.

If you run racresetcfg from a network client (for example, a supported web browser, Telnet or SSH, or Remote RACADM), use the default IP address. The racresetcfg subcommand does not reset the cfgDNSRacName object.

To run this subcommand, you must have the Chassis Administrator privilege.

NOTE: Certain firmware processes must be stopped and restarted to complete the reset to defaults. CMC becomes unresponsive for about 30 seconds while this operation completes.

RACADM Subcommand Details 69

Page 70: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: There is a 100 percent fan request when the command is issued against the servers.

Synopsis • racadm racresetcfgRAC reset operation initiated successfully. It may take several minutes for the RAC to come online again.

• racadm racresetcfg [-m <module>] [-c <feature>]

Input • -m <module> — Specifies the device to reset the configuration on <module>. <module> must be one of the following values:

– chassis — Default state if -m is not specified

– server–<n> — where n=1–16

– server–<nx> — where n=1–8; x=a, b, c, d (lower case)

– kvm• -c <feature> — Must be one of the following values:

– ad — Reset Active Directory properties to default (default is disabled).

– pcap — Reset Power Cap to default.

– flex — Reset flexaddress properties to default (default is disabled).

– dpse — Reset Dynamic Power Supply Engagement to default (default is disabled).

NOTE: FlexAddress or FlexAddressPlus will be set to enabled on running racadm racresetcfg (default is enabled without –c option). The server must be turned off prior to running this command to change the slot state.

NOTE: -c option is valid with <module = chassis> only.

NOTE: If chassis is the target of racresetcfg, CMC resets after the operation.

Example • Reset the KVM configuration on CMC.racadm racresetcfg -m kvmThe configuration has initiated restoration to factory defaults.

• Reset blade 8 configuration from CMC.racadm racresetcfg -m server-8The RAC configuration has initiated restoration to factory defaults.

Wait up to a minute for this process to complete before accessing the RAC again.

remoteimage

Table 104. Details of remoteimage attribute

Description Connects, disconnects, or deploys a media file on a remote server.

To run this subcommand, you must log in with virtual media privilege for iDRAC.

Synopsis • racadm remoteimage -d • racadm remoteimage -s • racadm remoteimage –c –u <username> -p <password> -l <image_location>

Input • -c—Connect the image.

• -d—Disconnect image.

• -p—Password to access shared folder.

• -u—username to access shared folder.

70 RACADM Subcommand Details

Page 71: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• -l—Image location on the network share; use single quotation marks around the location.

• -s—Display status.

NOTE: Use a forward slash (/) when providing the image location. If backward slash (\) is used, override the backward slash for the command to run successfully.

For example:

racadm remoteimage -c -u user -p xxx -l /\/\192.168.0.2/\CommonShare/\diskette

NOTE: The following options only apply to connect and deploy actions

• -u —Username

User name to access the network share. For domain users, you can use the following formats:

– domain/user

– domain\user

– user@domain

• -p —Password to access the network share.

Example • Configure a Remote image.racadm remoteimage -c -u "user" -p "xxx" -l //shrloc/foo.iso Remote Image is now Configured

• Disable Remote File Sharing.racadm remoteimage -dDisable Remote File Started. Please check status using -s option to know Remote File Share is ENABLED or DISABLED.

• Check Remote File Share status.racadm remoteimage -sRemote File Share is EnabledUserNamePasswordShareName //192.168.0/xxxx/dtk_3.3_73_Linux.iso

• Deploy a remote image on iDRAC CIFS Share.racadm remoteimage –c –u admin –p xxx –l 192.168.0.1:/dev/floppy.img

• Deploy a remote image on iDRAC NFS Share.racadm remoteimage –c –u admin –p xxx –l 192.168.0.1:/dev/floppy.img

• Deploy a remote image on iDRAC HTTP Share.racadm remoteinage -c -u "user" -p "xxx" -l http://shrloc/foo.iso

• Deploy a remote image on iDRAC HTTPS Share.racadm remoteinage -c -u "user" -p "xxx" -l https://shrloc/foo.iso

NOTE: The -p and -u options are mandatory only for CIFS share and not mandatory for NFS, HTTP, and HTTPS.

set

Table 105. Details of set attribute

Description Import saved CMC configuration or CMC Event Filter configuration from a file.

RACADM Subcommand Details 71

Page 72: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: If CMC is not in the network, you cannot import the chassis configuration profile from a remote network share with proxy using the set command. But, you can import the chassis

configuration profile from the local management station.

Synopsis racadm -r <CMC IP> -u <CMC username> -p <CMC password> set -f <filename>racadm -r <CMC IP> -u <CMC username> -p <CMC password> set -f <filename> -t xmlracadm set -f <filename> -t xml -l <NFS share>racadm set -f <filename> -t xml -l <CIFS share> -u <username> -p <password>

Input • -f: import CMC configuration or CMC event filter from a file.

• -u: username of the remote share from where the file must be imported.

• -p: password for the remote share from where the file must be imported.

• -l: network share location from where the file must be imported.

• -t: specify the file type to be imported. The valid value is xml. This option is case-insensitive.

Example • Configure event filter configurations from a configuration file using remote racadmracadm -r 192.168.0.120 -u <username> -p <password> set -f file.txt

• Configure a CMC from an XML configuration file on a local share using remote racadmracadm -r 192.168.0.120 -u <username> -p <password> set -f myfile.xml -t xml

• Configure a CMC from an XML configuration file on a remote CIFS shareracadm set -f myfile.xml -t xml -u myuser -p mypass -l //192.168.0.0/myshare

• Configure a CMC from an XML configuration file on a remote NFS shareracadm set -f myfile.xml -t xml -l 192.168.0.0:/myshare

serveraction

Table 106. Details of serveraction attribute

Description Enables you to perform power management operations on the blade system.

To run this subcommand, you must have the Execute Server Control Commands permission.

Synopsis • racadm serveraction -a <action> • racadm serveraction -m <module> <action>

Input • -m <module> — Must be one of the following values:

– server–<n>: where n=1–16

– server–<nx>: where n=1–8; x=a–d (enter lowercase letter only).

• -a — Performs power action on all servers. Not allowed with the powerstatus action.

<action> — Specifies the power management operation to perform. The options are:

• hardreset — Performs a force reset (reboot) operation on the managed system.

• powercycle — Performs a power-cycle operation on the managed system. This action is similar to pressing the power button on the system’s front panel to turn off and then turn on the system.

NOTE: The -m and -a options are applicable only to CMC platforms.

NOTE: If the server is in turned off state, the powercycle option power-up the server.

72 RACADM Subcommand Details

Page 73: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• powerdown — Powers down the managed system.

• powerup — Powers up the managed system.

• powerstatus — Displays the current power status of the server (ON or OFF).

• graceshutdown — Performs a graceful shutdown of the server. If the operating system on the server cannot shut down completely, then this operation is not performed.

• nmi — Generates the Non-masking interrupt (NMI) to halt the system operation. The NMI sends a high-level interrupt to the operating system, which causes the system to halt the operation to allow critical diagnostic or troubleshooting activities.

NOTE:

The halt system operation does not occur on systems running the Linux operating system.

• -f — Force the server power management operation.

• reseat — Performs virtual reseat of the server. This operation simulates reseating the blade by resetting the iDRAC on that blade. -f is required for this operation.

NOTE: The action powerstatus is not allowed with -a option.

Output Displays an error message if the requested operation is not completed, or a success message if the operation is completed.

Example • Power down the operating system on the server by using the following command:racadm serveraction powerdownPowers down the managed system

• Reseat blade 2 on CMC by using the following command:racadm serveraction -m server-2 reseat -fServer power operation successful

• Turn off the server 16 from CMC by using the following command:racadm serveraction -m server-16 powerdownServer power operation successful

• Get Power Status of blade 16 on CMC by using the following command:racadm serveraction -m server-16 powerstatus ON

• Turn off the server 16 from CMC, when the power is already turned off on that server by using the following command:racadm serveraction -m server-16 powerdownServer is already powered OFF.

• Power action on all servers by using the following command:racadm serveraction -a powerup

setarraycfg

Table 107. Details of setarraycfg attribute

Description To configure storage array properties, run this command.

Synopsis • racadm setarraycfg -m module –n <member_name> <member_ip> <member_mask> <member_gateway> -e 0|1 -g <groupname> <group_id> <group_password> [<admin_password>] [-f A|B]

• racadm setarraycfg -f A|B

NOTE: The valid value for -m is server–n, where n=1–16.

Input • -m — Module is one of the following values:

– server–<n>: where n = 1–7 and 9–15

RACADM Subcommand Details 73

Page 74: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• <member_name> — A unique and descriptive name that is fewer than 64 alphanumeric characters, without spaces. The first character is a letter or a number. It is used only to identify and administer the array.

• <member_ip> — Each member IP Network address must have at least one network interface on the same subnet as the group IP address.

• <member_mask> — Member Netmask combines with the member IP address to identify the subnet on which the network interface specified resides. The default is 255.255.255.0

• <member_gateway> — Member Gateway network address is for the device that connects the subnet and forward the network traffic beyond the local network.

• —e — Selects existing or create new group for a member. The valid values are:

– 0 — to create new group

– 1 — to use existing group

NOTE: If —e is 0, then admin password is mandatory.

• <group_name> — Name of the group for administrative purpose. You can use up to 64 alphanumeric characters and hyphens. The first character must be a letter or number.

• <group_ip> — Group IP and Network address for the group. The group IP address is used for administrative and host access to volumes.

• <group_password> — Group Membership Management Password is required when adding members to the group. The password must have 3 to 16 alphanumeric characters and is case-sensitive.

• <admin_password> — Group Administration Password to set admin password when creating new group and overrides the factory-set password. grpadmin is the default grpadmin account. The password must have 3 to 16 alphanumeric characters and is case-sensitive.

• —f — The valid values are A or B. Select Fabric used for data I/O. Options are:

– Fabric A (LOM port)

– Fabric B (mezzanine port)

The default is Fabric B. If the option is not specified, then the configuration is not done.

Output <module> configuration was initiated successfully. It may take several minutes to complete.

Example • Set member name, member IP, member netmask, member gateway with new group name, group IP, group password, admin password selecting fabric A on server-1.racadm setarraycfg -m server-1 -n cmc-col 192.168.1.233 255.255.255.0 192.168.1.0 -e 0 -g cmc-array-grp 192.168.1.10 <password> -f A

• Set member name, member IP, member netmask, member gateway with existing group name, group IP, group password selecting fabric B on server-1.racadm setarraycfg -m server-1 -n cmc-col 192.168.1.233 255.255.255.0 192.168.1.0 -e 1 -g cmc-array-grp 192.168.1.10 <password> -f B

• Select different fabric type.racadm setarraycfg -m server-3 -f A

setassettag

Table 108. Details of setassettag attribute

Description Sets the N-byte ASCII asset tag for the chassis.

To use this subcommand, you must have the Administrator privilege.

NOTE: The special characters “ (double quotation mark), ‘ (backward quotation mark), & (ampersand), and \ (backward slash) are not supported for this subcommand.

Synopsis racadm setassettag -m module <assettag>

Input -m <module> — Specifies the module whose asset tag you want to set.

Legal value: chassis

74 RACADM Subcommand Details

Page 75: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

You can obtain the same output if you do not include this option, as there is only one legal value.

<assettag> is a maximum of 64 non-extended ASCII characters.

Example • racadm setassettag -m chassis 783839–33• racadm setassettag 783839–33

The asset tag was changed successfully.

setchassisname

Table 109. Details of setchassisname attribute

Description Sets the name of the chassis in the LCD.

To run this subcommand, you must have the Administrator privilege.

NOTE: The special characters “ (double quotation mark), ‘ (backward quotation mark), & (ampersand), > (greater than), < (less than), and \ (backward slash) are not supported for this subcommand.

Synopsis racadm setchassisname <name>NOTE: Chassis name is a maximum of 64 nonextended ASCII characters.

Example racadm setchassisname dellchassis-1The chassis name was set successfully.

setflexaddr

Table 110. Details of setflexaddr attribute

Description Enables or disables FlexAddress on a particular slot or fabric.

To run this subcommand, you must have the Chassis Configuration Administrator privilege.

If the fabric type is determined to be InfiniBand, the operation is canceled and the command returns an error. If the FlexAddress feature is not activated, the command returns an error.

NOTE: The server must be turned off to change the slot state. All servers must be turned off to change the fabric state. The MAC/WWN addresses must be managed locally (not by an external console) to run this command.

Synopsis • racadm setflexaddr -i <slotNum> 0|1 • racadm setflexaddr -f <fabricName> 0|1

Input • -i <slotNum> — Enables or disables FlexAddress for the specified slot.

• -f <fabricName> — Enables or disables FlexAddress for the specified fabric.

• <slotNum>= 1–16

• <fabricName>= A, B, C, iDRAC

– 0 : Disable

– 1 : Enable

Example • Disable flexaddress for slot 2.racadm setflexaddr -i 2 0

RACADM Subcommand Details 75

Page 76: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• Enable flexaddress for fabric A.racadm setflexaddr -f A 1

• Disable flexaddress for fabric B.racadm setflexaddr -f b 0

• Disable flexaddress for fabric iDRAC.racadm setflexaddr -f idrac 0

setled

Table 111. Details of setled attribute

Description Sets the state (blinking or not blinking) of the LED on the specified module.

To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator privilege. To enable the servers to blink or unblink, you must have the Server Administrator or the Debug Administrator privilege.

Synopsis racadm setled -m <module> -l <ledState>

Input • -m <module> — Specifies the module whose LED you want to configure.

<module> can be one of the following:

– server–<n>, where n=1–16

– server–<nx>, where n=1–8; x = a, b, c, d (lower case)

– switch–<n>, where n=1–6

– cmc-active

– chassis

• -l <ledState> — Specifies the LED state. The values are:

– 0 — No Blinking

– 1 — Blinking

Example • racadm setled -m chassis -l 1Sets LED state on Chassis to Blink

• racadm setled -m server-1 -1 1LED state was set successfully.

• racadm setled -m server-9 -1 1 ERROR: Server in slot 9 is an extension of the server in slot 1.

NOTE: The setled command generates an error when run on the extension slot of a multi-slot server.

setniccfg

Table 112. Details of setniccfg attribute

Description Sets the CMC IP address for static and DHCP modes.

To run this subcommand, you must have the Configure Chassis Administrator privilege.

NOTE: The command helps to modify network configuration properties.

76 RACADM Subcommand Details

Page 77: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: The terms NIC and Ethernet management port may be used interchangeably.

Synopsis • racadm setniccfg [-m <module>] -d [-6]• racadm setniccfg [-m <module>] -s <ipAddress> <netmask> <gateway>• racadm setniccfg [-m <module>] -s -6 <ipv6Address> <prefixlen> <gateway>

• racadm setniccfg [-m <module>] -v [<vlan_id> <vlan_priority>]• racadm setniccfg [-m chassis] -o• racadm setniccfg –p [-6]• racadm setniccfg [-m <module>] -k [<speed> <duplex>]• racadm setniccfg [-i <slot>] -v [<vlan_id> <vlan_priority>]

Input • -d — Enables DHCP for the NIC. It is enabled by default.

• -d6 — Enables AutoConfig for the NIC (default is disabled).

• -s — Enables static IP settings. The IPv4 address, netmask, and gateway must be specified. Otherwise, the existing static settings are used. <ipaddress>, <netmask>, and <gateway> must be typed as dot-separated strings.racadm setniccfg -s 192.168.0 255.255.255.0 192.168.0

• -s6 — Enables static IPv6 settings. The IPv6 address, Prefix Length, and the IPv6 Gateway can be specified.

• -o — Enable or disable NIC.

• -m<module> — Must be one of the following values:

– chassis — Default state if -m is not specified

– server–<n>: where n=1–16

– server–<nx>: where n=1–8; x=a–d (lower case)

– switch–<n>: where n=1–6

• -v — VLAN settings has following legal values: no arguments imply remove VLAN tag, not compatible with server–nx (for example "server–4b") notation <vlan_id>=between 1 and 4000, 4021 and 4094, inclusive <vlan_priority>=between 0 and 7, inclusive.

• -p — Disables IPv4(default) or IPv6 protocol.

• -k — Option has following legal values: no arguments imply autonegotiate <speed>=10, 100 <duplex> =half, full.

NOTE:

• -o, -k, -p: These options can be specified for chassis only

• -6: Sets static IPv6 addresses (with -soption). Enables autoconfig for IPv6 (with-d option) disables IPv6 (with-p option) can be specified for chassis or servers.

• -v: When performing on a switch, release and renew any DHCP lease on that port for changes to take effect.

Example • Configuration of Speed= 100 Mbps and duplex= full duplex.racadm setniccfg -k 100 full

• Configuration of Speed and Duplex to Autonegotiate.racadm setniccfg -k

• Configuration of VLAN id and priority of a slot or all blades in a sleeve.racadm setniccfg -i 5 -v 1000 7

• Configuration of CMC to a static IPv6 address.racadm setniccfg -m chassis -s -6 2001:DB8::2 64 2001:DB8::1

• Configuration of server to use stateless autoconfiguration address.racadm setniccfg -m server-1 -d -6

• Configuration of VLAN id and priority for a switch.racadm setniccfg -m switch-1 -v 1000 7

• Removal of VLAN configuration from a switch.racadm setniccfg -m switch-1 -v

RACADM Subcommand Details 77

Page 78: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• Configuration of redundant moderacadm setniccfg -r 1

setractime

Table 113. Details of setractime attribute

Description Sets the date and time on the CMC.

To run this subcommand, you must have the Administrator privilege.

Synopsis • racadm setractime -d <YYYYMMDDhhmmss.mmmmmmsoff>• racadm setractime -l <YYYYMMDDhhmmss>• racadm setractime -z ?|<timezone>|<timezone-prefix>*

Input • -d — Sets the time in the string YYYYMMDDhhmmss.mmmmmmsoff, where:

– YYYY is the four digit year

– MM is the month

– DD is the day

– hh is the hour

– mm is the minute

– ss is the second

– mmmmmm is the number of microseconds

– s is a + (plus) sign or a − (minus) sign, which indicates the sign of the offset.

– off is the offset in minutes.

NOTE: Theoff is the offset in minutes from GMT and must be in 15-minute increments. The timezone is

represented as an offset from GMT. The clock does not automatically adjust to daylight savings time (for -d option).

• -z <zone> — Sets the time zone by name or index, or lists possible time zones. For example, PST8PDT (Western United States), 294 (Seoul), 344 (Sydney). <zone> may be:

– ? lists the major timezone names or prefixes.

– <timezone> is the case-sensitive name of your timezone or the index listed in -z <timezone_prefix>*.

– <timezone_prefix>* is a prefix of one or more timezones, followed by '*'.

NOTE: The timezone or daylight savings time is fully supported for -land -z options. To set the

timezone only (for example -z US/Central), do not specify the -l option.

• -l — Sets the local date and time in the string YYYYMMDDhhmmss where:

– YYYY is the year

– MM is the month

– DD is the day

– hh is the hour

– mm is the minute

– ss is the second

Setting the time using the -l and -z options are recommended. This command format allows the CMC to support local time zones. This command includes the ability to automatically adjust the CMC time to the local Daylight Savings Time (DST).

Example The setractime subcommand supports dates ranging from 1/1/1970 00:00:00 through 12/31/2030 23:59:59.

78 RACADM Subcommand Details

Page 79: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• To set the local time to November 24, 2012 at 3:02:30 pmracadm setractime -l 20121124150230The time was set successfully

• Set the timezone to 'US/Pacific':racadm setractime -z US/Pacific

• List all 'US' time zones:racadm setractime -z US*

setslotname

Table 114. Details of setslotname attribute

Description Sets the name of the slot in the chassis. Optionally, this command can be used to find if the slot name, host name, or iDRAC DNS name is displayed in the CMC User Interface or with the setslotname —i <slotNum> | —h command.

To run this subcommand, you must have the Administrator privilege.

NOTE:

• The special characters “ (double quotation mark), ‘ (backward quotation mark), & (ampersand), , (comma), \ (backward slash), ; (semicolon), ' (single quote), < (open angular bracket), and > (close angular bracket) are not supported for this subcommand.

• The OMSA server agent must be present and running on the server to use the Display Hostname feature. If the agent is not running, the setting is ignored. For more information, see the Dell OpenManage Server Administrator User's Guide at support.dell.com/manuals.

Synopsis • racadm setslotname -i<Slot_Number><Slot_Name_To_Be_Set>• racadm setslotname -h <value>

Input • —i <Slot_Number> — Displays the ID of the slot.

Legal values: 1–16

• <Slot_Name_To_Be_Set> — The new name assigned to the slot. The character limit for <Slot_Name_To_Be_Set> is 15.

• —h <values> — Displays the Hostname, Slotname, or iDRAC DNS name. The legal values are:

– 0 — Displays the Slotname

– 1 — Displays the Hostname

– 2 — Displays the iDRAC DNS name

Example • Set slot name for slot 3 to server3:racadm setslotname -i 3 server3The slot name was set successfully.

• Enable System to Display Hostnames (1 = Active):racadm setslotname -h 1

setsysinfo

Table 115. Details of setsysinfo attribute

Description Sets the name or location of the chassis.

To run this subcommand, you must have the Administrator privilege.

RACADM Subcommand Details 79

Page 80: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: The special characters “ (double quotation mark), ‘ (backward quotation mark), & (ampersand), > (greater than), < (less than), and \ (backward slash) are not supported for this subcommand.

Synopsis racadm setsysinfo -c chassisname|chassislocation <string>

Input • <string> — Indicates a maximum of 64 nonextended ASCII chassis name or location.

• -c — Sets the chassis name or location.

Example • racadm setsysinfo -c chassisname "Dell Rack System"The chassis name was set successfully

• racadm setsysinfo -c chassislocation chassislocation2Sets Chassis location.

sshpkauth

Table 116. Details of sshpkauth attribute

Description Enables you to upload and manage up to 4 different SSH public keys for each user. You can upload a key file or key text, view keys, or delete keys.

This command has three mutually exclusive modes determined by the options — upload, view, and delete.

To run this subcommand, you must have Configure user privilege.

NOTE: CMC accepts RSA keys up to key strength 4096, but the recommended key strength is 2048.

NOTE: CMC does not support DSA algorithm.

Synopsis • racadm sshpkauth -i svcacct -k <key_index> -p <privilege> -t <PK_key_text>• racadm sshpkauth -i svcacct -k <key_index> -p <privilege> -f <PK_key_text>• racadm sshpkauth -v -i svcacct -k all|<key_index>• racadm sshpkauth -d -i svcacct -k all|<key_index>

Input • -i <user_index> — Index for the user. It must be svcacct for CMC.

• -k [<key_index> | all] — Index to assign the PK key being uploaded. all only works with the -v or -d options. <key_index> must be between 1 to 6 or all on CMC.

• -p <privilege> — Level to give to user for this PK key.

• -r <cmcIpAddr> — Specifies the controller’s remote IP address.

• -u <username> — Specifies the user name.

• -t <PK_Key_Text> — Key text for the SSH Public key.

• -f <filename> — File containing the key text to upload.

NOTE: The -f option is not supported on Telnet or SSH or serial RACADM.

• -v — View the key text for the index provided.

• -d — Delete the key for the index provided.

Example

• Upload an invalid key to iDRAC User 2 in the first key space using a string.

$ racadm sshpkauth -i 2 -k 1 -t "This is invalid keyText"ERROR: Key text appears to be corrupt

80 RACADM Subcommand Details

Page 81: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• Upload a valid key to iDRAC User 2 in the first key space using a file.

$ racadm sshpkauth -i 2 -k 1 -f pkkey.keyKey file successfully uploaded.

• Get all keys for User 2 on iDRAC.

$ racadm sshpkauth -v -i 2 -k all********************* User ID 2 ******************Key ID 1:ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAzzy+k2npnKqVEXGXIzo0sbR6JgA5YNbWs3ekoxXV fe3yJVpVc/5zrrr7XrwKbJAJTqSw8Dg3iR4n3vUaP+lPHmUv5Mn55Ea6LHUslAXFqXmOdlThd wilU2VLw/iRH1ZymUFnut8ggbPQgqV2L8bsUaMqb5PooIIvV6hy4isCNJU=1024-bit RSA, converted from OpenSSH by [email protected] ID 2:Key ID 3:Key ID 4:

sslcertdownload

Table 117. Details of sslcertdownload attribute

Description Downloads an SSL certificate from CMC to the client’s file system.

To run this subcommand, you must have the Server Control privilege.

NOTE: This subcommand is only supported on the remote interface(s).

Synopsis racadm sslcertdownload -f <filename> -t <type>

Input • -f — Specifies the target filename on local file system to download the certificate.

• -t <type> — Specifies the type of certificate to download, either the CA certificate for Directory Service or the server certificate.

– 1=server certificate

– 2=Active Directory

Output Returns 0 when successful and non-zero number when unsuccessful.

Example • Download server certificate:racadm -r 192.168.0 -u root -p xxx sslcertdownload -t 1 -f cert.txt

• Download Active Directory certificate:racadm -r 192.168.0 -u root -p xxx sslcertdownload -t 2 -f ad_cert.txt

NOTE: This command is not supported in the firmware RACADM interface as it is not a file system.

sslcertupload

Table 118. Details of sslcertupload attribute

Description Uploads a custom SSL server or CA certificate for Directory Service from the client to CMC.

To run this subcommand, you must have the Server Control privilege.

RACADM Subcommand Details 81

Page 82: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: This subcommand is only supported on the remote interfaces.

Synopsis racadm sslcertupload -f <filename> -t <type>

Input • -t <type> — Specifies the type of certificate to upload. The type of certificate must be:

– 1 — server certificate

– 2 — Active Directory

– 5 — Kerberos Keytab

– 6 — Server certificate and key

• -f — Specifies the source filename in the local file system of the certificate uploaded.

• -k — Specifies optional source filename for private key when using type 6.

Output racadm -r 192.168.0.2 -u root -p xxx sslcertupload -t 2 -f cert.txtCertificate successfully uploaded to the RAC.

Example • Uploading a server certificate.racadm -r 192.168.0.2 -u root -p xxx sslcertupload -t 1 -f cert.txt

• Upload web server certificate and keyracadm -r 192.168.0.2 -u root -p xxx sslcertupload -t 6 -f cert.txt -k key.txt

• Uploading Active Directory Certificateracadm -r 192.168.0.2 -u root -p xxx sslcertupload -t 2 -f ad_cert.txt

sslcertview

Table 119. Details of sslcertview attribute

Description Displays the SSL server or CA certificate that exists on CMC.

Synopsis racadm sslcertview -t <type> [-A]

Input • -t — Specifies the type of certificate to view, either the CA certificate or server certificate.

– 1=server certificate

– 2=Active Directory

• -A — Prevents printing headers or labels.

NOTE: If a certificate is generated using comma ‘,’ as one of the parameters for the Organization Name, Common Name, Location Name, or State Name, then this command displays the partial name in the respective fields only up to the comma. The rest of the string is not displayed.

NOTE: For self-signed certificate, the common name includes PQDN (Partially qualified domain name) or FQDN (Fully qualified domain name).

Table 120. Output

Serial Number 01

Subject Information:

Country Code (CC) US

State (S) Texas

82 RACADM Subcommand Details

Page 83: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Locality (L) Round Rock

Organization (O) Dell Inc.

Organizational Unit (OU) Remote Access Group

Common Name (CN) CMC Default certificate

Issuer Information:

Country Code (CC) US

State (S) Texas

Locality (L) Round Rock

Organization (O) Dell Inc.

Organizational Unit (OU) Remote Access Group

Common Name (CN) CMC Default certificate

Valid From Jul 7 23:54:19 2011 GMT

Valid To Jun 4 23:54:19 2021 GMT

racadm sslcertview -t 1 -A

00USTexasRound RockDell Inc.Remote Access GroupCMC default certificateUSTexasRound RockDell Inc.Remote Access GroupCMC default certificateJun 7 23:54:19 2011 GMTJun 4 23:54:19 2021 GMT

sslcsrgen

Table 121. Details of sslcsrgen attribute

Description Generates and downloads a certificate signing request (CSR) file to the client’s local file system. The CSR can be used for creating a custom SSL certificate that can be used for SSL transactions on CMC.

To run this subcommand, you must have the Configure chassis administrator privilege.

Synopsis • racadm sslcsrgen -g

RACADM Subcommand Details 83

Page 84: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• racadm sslcsrgen [-g] [-f <filename>]• racadm sslcsrgen -s

Input • -g — Generates a new CSR.

• -s — Returns the status of a CSR generation process (generation in progress, active, or none).

• -f — Specifies the filename of the location, <filename>, where the CSR is downloaded.

NOTE:

• If the -f option is not specified, the filename defaults to sslcsr in your current directory.

• The -f option is only supported on the remote interface(s).

Output If no options are specified, a CSR is generated and downloaded to the local file system as sslcsr by default. The -g option cannot be used with the -s option, and the -f option can only be used with the -g option.

The sslcsrgen -s subcommand returns one of the following status codes:

• CSR was generated successfully.

• CSR does not exist.

Example • Display current status of CSR operation:racadm sslcsrgen -sorracadm sslcsrgen -g -f c:\csr\csrtest.txt

• Generate and download a CSR to local file system:racadm -r 192.168.0.120 -u root -p calvin sslcsrgen -g -f csrtest.txt

NOTE: Before a CSR can be generated, the CSR fields must be configured in the RACADM config —g cfgracsecurity group. For example:

racadm config -g cfgracsecurity -o cfgRacSecCsrCommonName cmc-effort.cmc.comNOTE: In Telnet or SSH console, you can only generate and not download the CSR file.

NOTE: The duration for generating a CSR key depends on the length specified for the key.

sslresetcfg

Table 122. Details of sslresetcfg attribute

Description Restores the web-server certificate to factory default and restarts web-server. The certificate takes effect 30 seconds after the command is entered.

To run this subcommand,you must have the Chassis Configuration Administrator privilege.

Synopsis racadm sslresetcfg

Input N/A

Example racadm sslresetcfgCertificate generated successfully and webserver restarted.

testcifsshareDescription Tests the Common Internet File System (CIFS) share with the current SMB version.

84 RACADM Subcommand Details

Page 85: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Synopsis racadm testcifsshare -u <username> -p <password> -l <CIFS share>

Input The options are:

• -u—User name of the CIFS share that must be tested.

• -p—Password for the CIFS share that must be tested.

• -l—The CIFS share location that must be tested.

Example racadm testcifsshare -u shareme -p shareme -l //100.97.174.77/lccifs

testemail

Table 123. Details of testemail attribute

Description Sends a test email from CMC to a specified destination. Prior to running the test email command, make sure that the SMTP server is configured.

Synopsis racadm testemail -i <index>

Input -i <index> — Specifies the index of the email alert to test.

Output Success: Test e-mail sent successfullyFailure: Unable to send test e-mail

testfeature

Table 124. Details of testfeature attribute

Description Tests CMC feature x.

Synopsis • racadm testfeature -f AD -u <user_at_domain> -p <password> [-d <debug_level>]• racadm testfeature -f ADKRB -u <user_at_domain> -p <password> [-d

<debug_level>]• racadm testfeature -f LDAP -u <user> -p <password> [-d <debug_level>]

Input • -f <feature> — options are:

– AD — Test AD using simple authentication

– ADKRB — Test AD using Kerberos authentication

– LDAP — Test Generic LDAP

• -u <user>— On the basis of a feature, <user> is user or user_at_domain.

• -p <password> — Password for the user.

• -d <debug_level> — The following bitmask:

– 0x00 — quiet

– 0x01 — verbose

– 0x02 — debug

– 0x04 — info

– 0x08 — warning

– 0x10 — errors

– 0x20 — fatal

– 0x40 — checks

RACADM Subcommand Details 85

Page 86: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

– 0xff — all debug information

– 0xd0 — default debug level for AD and ADKRB.– 0xf0 and 0xf2 — default debug level for LDAP.

NOTE: -d option is only supported on the firmware interface or firmware interfaces.

Example • To test AD.

racadm testfeature -f AD -u [email protected] -p dell123• To test ADKRB:.

racadm testfeature -f ADKRB -u [email protected]• To test LDAP.

racadm testfeature -f LDAP -u joe -p dell123 -d 0xf2

testtrap

Table 125. Details of testtrap attribute

Description Tests the RAC’s SNMP trap alerting feature by sending a test trap from CMC to a specified destination trap listener on the network.

To run this subcommand, you must have the Test Alert permission.

NOTE: Before you run the testtrap subcommand, make sure that the specified index in the cfgAlerting

group is configured properly.

Synopsis racadm testtrap -i <index>

Input -i <index> — Specifies the index of the trap configuration that must be used for the test. Valid values are from 1

to 4.

Example • Send a test trap to the destination configured for index 1:racadm testtrap -i 1

traceroute

Table 126. Details of traceroute attribute

Description Traces network path of the routers as the packets traverse from the system to a destination IPv4 address.

To run this subcommand, you must have the Administrator privilege.

Synopsis racadm traceroute <IPv4 address>

Input IPv4 — Specifies IPv4 address.

Output traceroute to 192.168.0.1 (192.168.0.1), 30 hops max, 40 byte packets1 192.168.0.1 (192.168.0.1) 0.801 ms 0.246 ms 0.253 ms

86 RACADM Subcommand Details

Page 87: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

traceroute6

Table 127. Details of traceroute6 attribute

Description Traces the network path of routers as the packets traverse from the system to a destination IPv6 address.

To run this subcommand, you must have the Administrator privilege.

Synopsis racadm traceroute6 <IPv6address>

Input <IPv6address> – Specifies IPv6 address.

Output traceroute to fd01::1 (fd01::1) from fd01::3,30 hops max, 16 byte packets1 fd01::1 (fd01::1) 14.324 ms 0.26 ms 0.244 ms

RACADM Subcommand Details 87

Page 88: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

CMC Property Database Group and Object Descriptions

CMC property database contains the configuration information. Associated object is organizing data, and object group is organizing object. The IDs for the groups and objects that the property database supports are listed in this section.

To configure CMC, use the group and object IDs with the RACADM subcommands.

NOTE: You can configure a setting that does not have a hash symbol (#) as the prefix in its output name. To modify a configurable object, use the -o option.

NOTE: Racadm sets the value of objects without performing any functional validation on them. For example, RACADM allows you to set the Certificate Validation object to 1 with the Active Directory object set to 0, even though Certificate Validation can happen only if Active Directory is enabled. Similarly, the cfgADSSOEnable object can be set to 0 or 1 even if the cfgADEnable object is 0, but it takes effect only if Active Directory is enabled.

All string values are limited to displayable ASCII characters, except where otherwise noted.

Topics:

• Displayable Characters

• idRacInfo

• cfgLanNetworking

• cfgRemoteHosts

• cfgUserAdmin

• cfgEmailAlert

• cfgSessionManagement

• cfgSerial

• cfgOobSnmp

• cfgTraps

• cfgRacTuning

• cfgServerInfo

• cfgActiveDirectory

• cfgLDAP

• cfgLDAPRoleGroup

• cfgStandardSchema

• cfgLocation

• cfgChassisPower

• cfgThermal

• cfgKVMInfo

• cfgLcdInfo

• cfgAlerting

• cfgIPv6LanNetworking

• cfgCurrentLanNetworking (Read Only)

• cfgCurrentIPv6LanNetworking (Read Only)

3

88 CMC Property Database Group and Object Descriptions

Page 89: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• cfgNetTuning

• cfgRacSecurity

• cfgQuickDeploy

Displayable CharactersDisplayable characters include the following set:

abcdefghijklmnopqrstuvwxwz

ABCDEFGHIJKLMNOPQRSTUVWXYZ

0123456789~`!@#$%^&*()_+-={}[]|\:";'<>,.?/

Table 128. Details of Displayable Characters

Subcommand CMC

idRacInfo Yes

cfgLanNetworking Yes

cfgRemoteHosts Yes

cfgUserAdmin Yes

cfgEmailAlert Yes

cfgSessionManagement Yes

cfgSerial Yes

cfgOobSnmp Yes

cfgTraps Yes

cfgRacTuning Yes

cfgServerInfo Yes

cfgActiveDirectory Yes

cfgStandardSchema Yes

cfgLDAP Yes

cfgLdapRoleGroup Yes

cfgLocation Yes

cfgChassisPower Yes

cfgThermal Yes

cfgKVMInfo Yes

cfgAlerting Yes

CMC Property Database Group and Object Descriptions 89

Page 90: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Subcommand CMC

cfgLcdInfo Yes

cfgIPv6LanNetworking Yes

cfgCurrentLanNetworking Yes

cfgCurrentIPv6LanNetworking Yes

cfgNetTuning Yes

cfgRacSecurity Yes

idRacInfoThis group contains display parameters to provide information about the specifics of CMC being queried. One instance of the group is allowed. Use this object with the getconfig subcommand.

To use this object, you must have the CMC Login User privilege.

The following sections provide information about the objects in the idRACInfo group.

idRacProductInfo (Read Only)

Table 129. Details of Read only attribute - idRacProductInfo

Description A text string that identifies the product.

Legal Values A string of up to 63 ASCII characters.

Default Chassis Management Controller

idRacDescriptionInfo (Read Only)

Table 130. Details of Read only attribute - idRacDescriptionInfo

Description A text description of the RAC type.

Legal Values A string of up to 255 ASCII characters.

Default This system component provides a complete set of remote management functions for Dell PowerEdge servers.

90 CMC Property Database Group and Object Descriptions

Page 91: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

idRacVersionInfo (Read Only)

Table 131. Details of Read only attribute - idRacVersionInfo

Description String containing the current product firmware version

Legal Values A string of up to 63 ASCII characters.

Default The current version number.

idRacBuildInfo (Read Only)

Table 132. Details of Read only attribute - idRacBuildInfo

Description String containing the current RAC firmware build version.

Legal Values A string of up to 16 ASCII characters.

Default The current CMC firmware build version.

idRacName (Read Only)

Table 133. Details of Read only attribute - idRacName

Description A user-assigned name to identify this controller.

Legal Values A string of up to 15 ASCII characters.

Default CMC

iDRAC Type (Read Only)

Table 134. Details of Read only attribute - iDRAC Type

Description Identifies the remote access controller type.

Legal Values Product ID

Default 9

Example

racadm getconfig -g idRacInfo# idRacType=8# idRacProductInfo=Chassis Management Controller# idRacDescriptionInfo=This system component provides a complete

CMC Property Database Group and Object Descriptions 91

Page 92: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

set of remote management functions for blade servers# idRacVersionInfo=P21# idRacBuildInfo=200708301525# idRacName=CMC-1racadm getconfig -g idRacInfo# idRacType=16# idRacProductInfo=Integrated Dell Remote Access Controller# idRacDescriptionInfo=This system component provides a complete set of remote management functions for Dell PowerEdge Servers# idRacVersionInfo=1.06.06# idRacBuildInfo=15# idRacName=idrac-GSRS3V1

cfgLanNetworkingThis group contains parameters to configure CMC NIC for IPv4.

One instance of the group is allowed. Some objects in this group may require CMC NIC to be reset, which may cause a brief loss in connectivity. Objects that change CMC NIC IP address settings close all active user sessions and require users to reconnect using the updated IP address settings.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

NOTE: You can configure a setting that does not have a hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

The following sections provide information about the objects in the cfgLanNetworking group.

cfgNicIPv4Enable (Read or Write)

Table 135. Details of cfgNicIPv4Enable attribute

Description Enables or disables IPv4 stack.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

cfgNicVLanEnable (Read or Write)

Table 136. Details of attribute - cfgNicVLanEnable

Description Enables or disables the VLAN capabilities.

All chassis management traffic, including the CMC and all iDRACs, resides on this external VLAN when enabled. No iDRAC configuration change is required to use this external management network VLAN.

Legal Values • 1 (TRUE)

• 0 (FALSE)

92 CMC Property Database Group and Object Descriptions

Page 93: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Default 0

Example racadm config -g cfgLanNetworking -o cfgNicVLanEnable1racadm config -g cfgLanNetworking -o cfgNicVLanEnable0

cfgNicVLanID (Read or Write)

Table 137. Details of attribute - cfgNicVLanID

Description Specifies the VLAN ID for the network VLAN configuration. This property is only valid if cfgNicVLanEnable is set to 1(enabled).

Legal Values 1–4000 and 4021–4094

Default 1

Example racadm config -g cfgLanNetworking -o cfgNicVlanID1

cfgNicVLanPriority (Read or Write)

Table 138. Details of attribute - cfgNicVLanPriority

Description Specifies the VLAN Priority for the network VLAN configuration. This property is only valid if cfgNicVLanEnable is set to 1 (enabled).

Legal Values 0–7

Default 0

Example racadm config -g cfgLanNetworking -ocfgNicVLanPriority 7

cfgDNSDomainName (Read or Write)

Table 139. Details of attribute - cfgDNSDomainName

Description In the DNS domain name, parameter is only valid if cfgDNSDomainNameFromDHCP is set to 0(FALSE).

Legal Values A string of up to 254 ASCII characters. At least one of the characters must be alphabetic. Characters are restricted to alphanumeric, '-', and '.'.

NOTE: Microsoft Active Directory only supports Fully Qualified Domain Names (FQDN) of 64 bytes or fewer.

Default <blank>

CMC Property Database Group and Object Descriptions 93

Page 94: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgDNSDomainNameFromDHCP (Read or Write)

Table 140. Details of attribute - cfgDNSDomainNameFromDHCP

Description Specifies that CMC DNS domain name must be assigned from the network DHCP server.

Legal Values • 1 — True

• 0 — False

Default 0

This property is used only if cfgNicUseDhcp is set to 1(true), or if both cfgIPv6Enable and cfgIPv6AutoConfig are set to

1(true).

The CMC can obtain its DNS domain name from either a DHCP or DHCPv6 server, if all of the following properties are set to 1 (true):

• cfgNicIPv4Enable• cfgNicUseDhcp• cfgIPv6Enable• cfgIPv6AutoConfig• cfgDNSDomainNameFromDHCP• cfgDNSDomainName (Read or Write)

The network administrator must make sure that these DHCP servers are configured to provide the same DNS domain name to the CMC, otherwise the domain name becomes unpredictable.

cfgDNSServersFromDHCP (Read or Write)

Table 141. Details of attribute - cfgDNSServersFromDHCP

Description Specifies if the DNS server IPv4 addresses must be assigned from the DHCP server on the network.

This property is used only if cfgNicUseDhcp value is set to 1 (true).

Legal Values • 1 — True

• 0 — False

Default 0

cfgDNSServer1 (Read or Write)

Table 142. Details of attribute - cfgDNSServer1

Description Specifies the IPv4 address for DNS server 1. This property is only valid if cfgDNSServersFromDHCP is set to 0 (FALSE).

94 CMC Property Database Group and Object Descriptions

Page 95: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: cfgDNSServer1 and cfgDNSServer2 may be set to identical values while swapping addresses.

Legal Values String representing a valid IPv4 address. For example: 192.168.0.20.

Default 0.0.0.0

cfgDNSRacName (Read or Write)

Table 143. Details of attribute - cfgDNSRacName

Description Displays the CMC name, which is Service Tag by default. This parameter is only valid if cfgDNSRegisterRac is set to 1 (TRUE).

Legal Values A string of up to 63 ASCII characters. At least one character must be alphabetic.

NOTE: Some DNS servers only register names of 31 characters or fewer.

Default cmc-<service tag>

cfgDNSRegisterRac (Read or Write)

Table 144. Details of attribute - cfgDNSRegisterRac

Description Registers the iDRAC or CMC name on the DNS server. When you set this parameter, the CMC registers its DNS name for its IPv4 and IPv6 addresses with the DNS server.

Legal Values • 1 — True

• 0 — False

Default 0

NOTE: For IPv6, only the DHCPv6 address or static address is registered.

CMC Property Database Group and Object Descriptions 95

Page 96: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example:

racadm getconfig -g cfgLanNetworkingcfgNicEnable=1cfgNicIPv4Enable=1cfgNicIpAddress=192.168.22.101cfgNicNetmask=255.255.255.0cfgNicGateway=192.168.22.101cfgNicUseDhcp=1# cfgNicMacAddress=00:00:00:00:00:01cfgNicVLanEnable=0cfgNicVLanID=1cfgNicVLanPriority=0cfgDNSServersFromDHCP=1cfgDNSServer1=192.168.0.5cfgDNSServer2=192.168.0.6cfgDNSRacName=cmc-franklycfgDNSDomainName=fwad.labcfgDNSDomainNameFromDHCP=1cfgDNSRegisterRac=1

cfgDNSServer2 (Read or Write)

Table 145. Details of attribute - cfgDNSServer2

Description Retrieves the IPv4 address for DNS server 2. This parameter is only valid if cfgDNSServersFromDHCP is set to 0 (FALSE).

NOTE: cfgDNSServer1 and cfgDNSServer2 may be set to identical values while swapping addresses.

Legal Values String representing a valid IPv4 address. For example: 192.168.0.20.

Default 0.0.0.0

cfgNicEnable (Read or Write)

Table 146. Details of attribute - cfgNicEnable

Description Enables or disables CMC network interface controller (NIC). If the NIC is disabled, the remote network interfaces to CMC are no longer accessible and CMC is only available through the local or serial RACADM interface.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 1

96 CMC Property Database Group and Object Descriptions

Page 97: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgNicIpAddress (Read or Write)

Table 147. Details of attribute - cfgNicIpAddress

Description Specifies the static IPv4 address.

NOTE: This parameter is only configurable if the cfgNicUseDhcp parameter is set to 0(FALSE).

Legal Values String representing a valid IPv4 address. For example: 192.168.0.20.

Default • 192.168.0.120

cfgNicNetmask (Read or Write)

Table 148. Details of attribute - cfgNicNetmask

Description The subnet mask used for IP address.

This property is only valid if cfgNicUseDhcp is set to0(FALSE).

NOTE: This parameter is only configurable if the cfgNicUseDhcp parameter is set to 0(FALSE).

Legal Values String representing a valid subnet mask. For example: 255.255.255.0.

Default 255.255.255.0

cfgNicGateway (Read or Write)

Table 149. Details of attribute - cfgNicGateway

Description Indicates the gateway IPv4 address.

The gateway IPv4 address used for static assignment of the RAC IP address. This property is only valid if cfgNicUseDhcp is set to0(FALSE).

NOTE: This parameter is only configurable if the cfgNicUseDhcp parameter is set to 0 (FALSE).

Legal Values String representing a valid gateway IPv4 address. For example: 192.168.0.1.

Default 192.168.0.1

CMC Property Database Group and Object Descriptions 97

Page 98: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgNicUseDhcp (Read or Write)

Table 150. Details of attribute - cfgNicUseDhcp

Description Specifies whether DHCP is used to assign the IPv4 address. If this property is set to 1 (TRUE) then the IPv4 address, subnet mask and gateway are assigned from the DHCP server on the network. If this property is set to 0(FALSE), the user can configure the cfgNicIpAddress, cfgNicNetmask and cfgNicGateway properties.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

cfgNicMacAddress (Read Only)

Table 151. Details of attribute - cfgNicMacAddress

Description The NIC MAC address in the format: dd:dd:dd:dd:dd:dd, where d is a hexadecimal digit in range 0 – 9, A — F

Legal Values String representing NIC MAC address.

Default The current MAC address of NIC. For example, 00:12:67:52:51:A3.

cfgRemoteHostsThis group provides properties that allow configuration of the SMTP server for email alerts.

This group enables/disables and configures firmware updates, NTP, remote syslogging and SMTP email alerting.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

The following sections provide information about the objects in the cfgRemoteHosts group.

cfgRhostsFwUpdateTftpEnable (Read or Write)

Table 152. Details of attribute - cfgRhostsFwUpdateTftpEnable

Description Enables or disables firmware update from a network TFTP server.

Legal Values • 1 — (TRUE)

• 0 — (FALSE)

Default 1

98 CMC Property Database Group and Object Descriptions

Page 99: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRhostsFwUpdateIpAddr (Read or Write)

Table 153. Details of attribute - cfgRhostsFwUpdateIpAddr

Description Specifies the network TFTP server IPv4 or IPv6 address that is used for TFTP firmware update operations.

Legal Values A string representing a valid IPv4 or IPv6 address. For example, 192.168.0.61

Default For IPv4, it is 0.0.0.0

cfgRhostsFwUpdatePath (Read or Write)

Table 154. Details of attribute - cfgRhostsFwUpdatePath

Description Specifies TFTP path where firmware image file exists on the TFTP server. The TFTP path is relative to the TFTP root path on the TFTP server.

NOTE: The server may still require you to specify the drive (for example, C:).

Legal Values A string with a maximum length of 255 ASCII characters.

Default <blank>

cfgRhostsSmtpServerIpAddr (Read or Write)

Table 155. Details of attribute - cfgRhostsSmtpServerIpAddr

Description The IPv4 or IPv6 address of the network SMTP server.

The SMTP server transmits email alerts from CMC if the alerts are configured and enabled.

Legal Values A string representing a valid SMTP server IPv4 or IPv6 address. For example: 192.168.0.2.

Default localhost.localdomain

cfgRhostsNtpEnable (Read or Write)

Table 156. Details of attribute - cfgRhostsNtpEnable

Description Enables or disables the use of the Network Time Protocol (NTP) for date and time synchronization.

Legal Values • 1 — True

• 0 — False

Default 0

CMC Property Database Group and Object Descriptions 99

Page 100: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRhostsNtpServer1 (Read or Write)

Table 157. Details of attribute - cfgRhostsNtpServer1

Description Specifies the first of three possible NTP servers.

Legal Values A string representing a valid NTP server. For example, ntp1.ntp.net. At least one NTP server must be specified and duplicate entries are not allowed.

Default Null

cfgRhostsNtpServer2 (Read or Write)

Table 158. Details of attribute - cfgRhostsNtpServer2

Description Specifies the second of three possible NTP servers.

Legal Values A string representing a valid NTP server. For example, ntp2.ntp.net. At least one NTP server must be specified and duplicate entries are not allowed.

Default Null

cfgRhostsNtpServer3 (Read or Write)

Table 159. Details of attribute - cfgRhostsNtpServer3

Description Specifies the third of three possible NTP servers.

Legal Values A string representing a valid NTP server. For example, ntp3.ntp.net. At least one NTP server must be specified and duplicate entries are not allowed.

Default Null

cfgRhostsNtpMaxDist (Read or Write)

Table 160. Details of attribute - cfgRhostsNtpMaxDist

Description Specifies the NTP maximum distance parameter used to aid in NTP configuration.

Legal Values 1–128

Default 16

100 CMC Property Database Group and Object Descriptions

Page 101: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRhostsSyslogEnable (Read or Write)

Table 161. Details of attribute - cfgRhostsSyslogEnable

Description To allow the RAC and SEL logs to be written to up to three remote syslog servers Enables or disables remote syslog.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

cfgRhostsSyslogPort (Read or Write)

Table 162. Details of attribute - cfgRhostsSyslogPort

Description Remote syslog port number to use for writing the RAC and SEL logs to a remote syslog server.

This setting takes effect only if the cfgRhostsSyslogEnable parameter is set to 1(enabled).

Legal Values 10–65535

NOTE: The following port numbers are reserved and cannot be used: 21, 68, 69, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, 60106.

Default 514

cfgRhostsSyslogServer1 Read or Write)

Table 163. Details of attribute - cfgRhostsSyslogServer1

Description To store the RAC and SEL logs specify the first of three possible remote syslog servers. This property is only valid if cfgRhostsSyslogEnable is set to 1 (enabled).

Legal Values Valid host name or IPv4 or IPv6 address.

Default <blank>

cfgRhostsSyslogServer2 Read or Write)

Table 164. Details of attribute - cfgRhostsSyslogServer2

Description To store the RAC and SEL logs Specify the second of three possible remote syslog servers. This property is only valid if cfgRhostsSyslogEnable is set to 1 (enabled).

Legal Values Valid host name or IPv4 or IPv6 address.

Default <blank>

CMC Property Database Group and Object Descriptions 101

Page 102: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRhostsSyslogServer3 Read or Write)

Table 165. Details of attribute - cfgRhostsSyslogServer3

Description To store the RAC and SEL logs specify the third of three possible remote syslog servers. This property is only valid if cfgRhostsSyslogEnable is set to 1(enabled).

Legal Values Valid host name or IPv4 or IPv6 address.

Default <blank>

cfgRhostsSyslogPowerLoggingEnabled Read or Write)

Table 166. Details of attribute - cfgRhostsSyslogPowerLoggingEnabled

Description To remote syslog servers, Enables or disables power consumption logging.

NOTE: Remote syslog must be enabled and more than one remote syslog servers must be configured to log the power consumption.

Legal Values • 1 — Enabled

• 0 — Disabled

Default 0

cfgRhostsSyslogPowerLoggingInterval (Read or Write)

Table 167. Details of attribute - cfgRhostsSyslogPowerLoggingInterval

Description Specifies the power consumption collection/logging interval.

Legal Values 1–1440 (minutes)

Default 5

Example

racadm getconfig -g cfgRemoteHosts [-m server-<n>]cfgRhostsFwUpdateTftpEnable=1cfgRhostsFwUpdateIpAddr=0.0.0.0cfgRhostsFwUpdatePath=cfgRhostsSmtpServerIpAddr=localhost.localdomaincfgRhostsNtpEnable=0cfgRhostsNtpServer1= cfgRhostsNtpServer2= cfgRhostsNtpServer3=cfgRhostsNtpMaxDist=16cfgRhostsSyslogEnable=0cfgRhostsSyslogPort=514cfgRhostsSyslogServer1=cfgRhostsSyslogServer2=

102 CMC Property Database Group and Object Descriptions

Page 103: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRhostsSyslogServer3=cfgRhostsSyslogPowerLoggingEnabled=1cfgRhostsSyslogPowerLoggingInterval=5

cfgUserAdminThis group provides configuration information about the users allowed to access CMC through the available remote interfaces.

Up to 16 instances of the user group are allowed. Each instance represents the configuration for an individual user.

NOTE: In the current CMC firmware version, the objects cfgUserAdminEnable and cfgUserAdminPrivilege are interrelated; changing the value of one property causes the value of the other property to change. For example, if a user does not have login privilege, the user is disabled by default. When you enable the user by changing the value of the UserAdminEnable to 1, the right-most digit of the UserAdminPrivilege also becomes 1. On the other hand, if you change the right-most digit of the UserAdminPrivilege to 0, the value of the UserAdminEnable becomes 0.

Use this object with the config or getconfig subcommands. To use the command as follows: -i <index group>, supply an index group

number

To use this object property, you must have the Chassis Configuration Administrator privilege.

NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

The following sections provide information about the objects in the cfgUserAdmin group.

cfgUserAdminIndex - Read Only

Table 168. Details of cfgUserAdminIndex attribute

Description The unique index of a user.

The index number is used to specify a unique group name. Only valid for indexed groups.

Legal Values The parameter specifies decimal integer 1–16.

Default <index of the instance>

cfgUserAdminPrivilege - Read or Write

Table 169. Details of cfgUserAdminPrivilege attribute

Description This property specifies the role-based authority privileges allowed for the user. The value is represented as a bit mask that allows for any combination of privilege values. The table below describes the user privilege bit values that can be combined to create bit masks.

Legal Values 0x0000000-0x0000fff, and 0x0

Default 0x00000000

CMC Property Database Group and Object Descriptions 103

Page 104: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Table 170. Example

iDRAC Specific User Privilege

Privilege Bit Mask

Log in to iDRAC 0x00000001

Configure iDRAC 0x00000002

Configure Users 0x00000004

Clear Logs 0x00000008

Execute Server Control Commands

0x00000010

Access Virtual Console

0x00000020

Access Virtual Media

0x00000040

Test Alerts 0x00000080

Execute Debug Commands

0x00000100

CMC Specific User Privilege

CMC Login User 0x0000001

Chassis Configuration Administrator

0x0000002

User Configuration Administrator

0x0000004

Clear Logs Administrator

0x0000008

Chassis Control Administrator

0x0000010

Super User 0x0000020

Server Administrator

0x0000040

Test Alert User 0x0000080

Debug Command Administrator

0x0000100

Fabric A Administrator

0x0000200

104 CMC Property Database Group and Object Descriptions

Page 105: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Fabric B Administrator

0x0000400

Fabric C Administrator

0x0000800

Table 171. Examples

User Privileges Privilege Bit Mask

The user is not allowed to access iDRAC or CMC

0x00000000

The user may only log in to iDRAC or CMC and view iDRAC or CMC and server configuration information.

0x00000001

The user may log in to iDRAC or CMC and change configuration.

0x00000001 + 0x00000002 = 0x00000003

The user may log in to iDRAC, access Virtual Media, and Virtual Console.

0x00000001 + 0x00000040 + 0x00000080 = 0x000000C1

cfgUserAdminUserName - Read or Write

Table 172. Details of cfgUserAdminUserName attribute

Description The name of the user for this index. Writing a string of double quotation mark (" ") disables the user. The string cannot contain / (forward slash), \ (backward slash), . (period), @ (at symbol), quotation marks, ; (semicolon), or ‘ (backward quotation mark).

NOTE: This property value must be unique among user names.

Legal Values A string of up to 16 ASCII characters.

Default • root (User 2)

• <blank> (All others)

CMC Property Database Group and Object Descriptions 105

Page 106: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgUserAdminPassword - Write Only

Table 173. Details of cfgUserAdminPassword attribute

Description The password for this user. User passwords are encrypted and cannot be seen or displayed after the property is written.

Legal Values A string of up to 20 ASCII characters.

Default ********

cfgUserAdminEnable - Read or Write

Table 174. Details of cfgUserAdminEnable attribute

Description Enables or disables an individual user.

NOTE: You can enable a user for a given index, only if you set the password for the same user.

Legal Values • 1 (TRUE)

• 0(FALSE)

Default 0

cfgEmailAlertThis group contains parameters to configure CMC email alerting capabilities. Up to four instances of this group are allowed.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privileges.

NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

The following sections provide information about the objects in the cfgEmailAlert group.

cfgEmailAlertIndex - Read Only

Table 175. Details of cfgEmailAlertIndex attribute

Description The unique index of an alert instance.

Legal Values 1–4

Default <instance>

106 CMC Property Database Group and Object Descriptions

Page 107: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgEmailAlertEnable - Read or Write

Table 176. Details of cfgEmailAlertEnable attribute

Description Enables or disables the alert instance.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

cfgEmailAlertAddress - Read or Write

Table 177. Details of cfgEmailAlertAddress attribute

Description Specifies the destination email address for email alerts, for example, [email protected].

Legal Values Email address format, with a maximum length of 64 ASCII characters.

Default <blank>

cfgEmailAlertEmailName - Read Only

Table 178. Details of cfgEmailAlertEmailName attribute

Description Specifies name or other identifier associated with the destination email address. The email name can refer to an individual, group, location, department, and so on.

Legal Values A string of up to 32 characters

Default <blank>

Example

racadm getconfig -g cfgEmailAlert -i 2# cfgEmailAlertIndex=1cfgEmailAlertEnable=1cfgEmailAlertAddress=kfulton@dell.comcfgEmailAlertName=Kevin Fulton

cfgSessionManagementThis group contains parameters to configure the number of sessions that can connect to CMC. One instance of the group is allowed. Displays current settings for and configures the idle timeout properties for web server, Telnet, SSH and RACADM sessions. Changes to idle time out settings take effect at the next login. To disable the idle time out property for a connection, set this property to 0.

The following sections provide information about the objects in the cfgSessionManagement group.

CMC Property Database Group and Object Descriptions 107

Page 108: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgSsnMgtRacadmTimeout (Read or Write)

Table 179. Details of cfgSsnMgtRacadmTimeout attribute

Description Defines the idle timeout in seconds for the Remote RACADM interface. If a remote RACADM session remains inactive for more than the specified sessions, the session closes.

Legal Values 10–1920

Default 30 minutes

Example

racadm getconfig -g cfgSessionManagement cfgSsnMgtWebserverTimeout=0cfgSsnMgtTelnetIdleTimeout=0cfgSsnMgtSshIdleTimeout=1800cfgSsnMgtRacadmTimeout=0

cfgSsnMgtWebserverTimeout (Read or Write)

Table 180. Details of cfgSsnMgtWebserverTimeout attribute

Description Defines the web server time-out. This property sets the amount of time (in seconds) that a connection is allowed to remain idle (there is no user input). The session is canceled if the time limit exceeds this property. Changes to this setting do not affect the current session. Log out and log in again to make the new settings effective.

An expired web server session logs out the current session.

Legal Values 60–10800

Default 1800

cfgSsnMgtSshIdleTimeout (Read or Write)

Table 181. Details of cfgSsnMgtSshIdleTimeout attribute

Description Defines the secure shell idle time-out. This property sets the amount of time (in seconds) that a connection is allowed to remain idle (there is no user input). The session is canceled if the time limit exceeds this property. Changes to this setting do not affect the current session; log out and log in again to make the new settings effective.

After the message is displayed, the system returns to the shell that generated the Secure Shell session.

Legal Values • 0 —(No timeout)

• 60–10800

NOTE: If 0 (no timeout), the network connection does not send alive packets to probe the client. Otherwise, keep alive packets are sent to guarantee that the client is responding.

Default 1800

108 CMC Property Database Group and Object Descriptions

Page 109: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgSsnMgtTelnetIdleTimeout - Read or Write

Table 182. Details of cfgSsnMgtTelnetIdleTimeout attribute

Description Defines the Telnet idle timeout. This property sets the amount of time in seconds that a connection is allowed to remain idle (there is no user input). The session is canceled if the time limit exceeds this property. Changes to this setting do not affect the current session (you must log out and log in again to make the new settings effective.)

After the message is displayed, the system returns you to the shell that generated the Telnet session.

• 0 (No timeout)

• 60–10800

NOTE: If 0 (no timeout is specified), the network connection does not send alive packets to probe the client. Otherwise, keep alive packets are sent to guarantee that the client is responding.

Default 1800

cfgSerialThis group contains configuration parameters for the serial configuration. One instance of the group is allowed.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

The following sections provide information about the objects in the cfgSerial group.

cfgSerialBaudRate - Read or Write

Table 183. Details of cfgSerialBaudRate attribute

Description Sets the baud rate on the serial port.

Legal Values 2400, 4800, 9600, 19200, 28800, 38400, 57600, 115200

Default 115200

cfgSerialConsoleEnable - Read or Write

Table 184. Details of cfgSerialConsoleEnable attribute

Description Enables or disables the serial console interface.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 1

CMC Property Database Group and Object Descriptions 109

Page 110: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgSerialConsoleQuitKey (Read or Write)

Table 185. Details of cfgSerialConsoleQuitKey attribute

Description

Legal value: NOTE: The CTRL key is represented by using the ^ (carat) character.

NOTE: The CTRL key does not generate a character by itself, but must be struck simultaneously with another key to generate a character.

For example, striking both the CTRL key and the \ key simultaneously (rather than sequentially) is denoted as ^\.

Configuration options: The value must start with the ^ character, and must follow one of the characters — a-z, A-Z, [,], \

In the input command, use \ without the quotes. For example:

config -g cfgSerial -o cfgSerialConsoleQuitKey "SHIFT+6"\\

Default:

cfgSerialConsoleIdleTimeout - Read or Write

Table 186. Details of cfgSerialConsoleIdleTimeout attribute

Description The maximum number of seconds to wait before an idle serial session is disconnected.

Legal Values • 0 = No timeout

• 60–1920

Default 1800

cfgSerialConsoleNoAuth - Read or Write

Table 187. Details of cfgSerialConsoleNoAuth attribute

Description Enables or disables the serial console login authentication.

Legal Values • 0 — (enables serial login authentication)

• 1 — (disables serial login authentication)

Default 0

110 CMC Property Database Group and Object Descriptions

Page 111: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgSerialConsoleCommand - Read or Write

Table 188. Details of cfgSerialConsoleCommand attribute

Description Specifies a serial command that is executed after a user logs in to the serial console interface.

Legal Values A string representing a valid serial command. For example, connect server-1.

Default <blank>

cfgSerialConsoleColumns - Read or Write

Table 189. Details of cfgSerialConsoleColumns attribute

Description Specifies the number of columns in the terminal window command line connected to the serial port. To take effect logout, and then log in again for the changes.

NOTE: The prompt counts as two characters.

NOTE: The terminal emulator must be configured with the line wrap mode ON, if a terminal emulator is used.

Legal Values 0–256

Default 0 (equivalent to 80)

cfgSerialHistorySize - Read or Write

Table 190. Details of cfgSerialHistorySize attribute

Description Specifies the maximum size of the serial history buffer.

Legal Values 0–8192

Default 8192

cfgSerialSshEnable - Read or Write

Table 191. Details of cfgSerialSshEnable attribute

Description Enables or disables the secure shell (SSH) interface.

Legal Values• 1 (TRUE)

• 0 (FALSE)

Default 1

CMC Property Database Group and Object Descriptions 111

Page 112: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example

racadm getconfig -g cfgSerialcfgSerialBaudRate=115200cfgSerialConsoleEnable=1cfgSerialConsoleQuitKey=^\cfgSerialConsoleIdleTimeout=1800cfgSerialConsoleNoAuth=0cfgSerialConsoleCommand=cfgSerialConsoleColumns=0cfgSerialHistorySize=8192cfgSerialTelnetEnable=0cfgSerialSshEnable=1

cfgSerialTelnetEnable - Read or Write

Table 192. Details of cfgSerialTelnetEnable attribute

Description Enables or disables the Telnet console interface.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

cfgOobSnmpThis group contains parameters to configure the SNMP agent and trap capabilities of CMC. One instance of the group is allowed.

The CMC SNMP agent supports the standard RFC1213 mib-2 and the Dell enterprise-specific the MIB.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

The following sections provide information about the objects in the cfgOobSnmp group.

cfgOobSnmpAgentCommunity (Read or Write)

Table 193. Details of cfgOobSnmpAgentCommunit attribute

Description Specifies the SNMP Community Name used for SNMP traps. The community string acts as a password shared between different hosts over the network. This community string value must match with the other hosts for any kind of communication through SNMP.

Legal Values A string of up to 31 characters.

Default public

112 CMC Property Database Group and Object Descriptions

Page 113: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example

racadm getconfig -g cfgOobSnmpcfgOobSnmpTrapsEnable=1cfgOobSnmpAgentCommunity=public

cfgOobSnmpAgentEnable (Read or Write)

Table 194. Details of cfgOobSnmpAgentEnable attribute

Description Enables or disables the SNMP agent in CMC.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

cfgOobSnmpProtocol

Table 195. Details of cfgOobSnmpProtocol attribute

Description Specifies the SNMP protocol used for SNMP traps.

Legal Values • 0 — All

• 1 — SNMPv3

Default 0

cfgOobSnmpTrapFormat

Table 196. Details of cfgOobSnmpTrapFormat attribute

Description Specifies the format for SNMP traps.

Legal Values • 0 — SNMPv1

• 1 — SNMPv2

• 2 — SNMPv3

Default 0

cfgTrapsThis group displays information for and configures delivery of SNMP traps for a specific user.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

CMC Property Database Group and Object Descriptions 113

Page 114: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

cfgTrapsIndex (Read Only)

Table 197. Details of cfgTrapsIndex attribute

Description Indicates the unique index of an alert instance.

Legal Values 1–4

Default 1

cfgTrapsEnable (Read or Write)

Table 198. Details of cfgTrapsEnable attribute

Description Enables or disables event traps on the CMC.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default None

cfgTrapsAlertDestIPAddr (Read or Write)

Table 199. Details of cfgTrapsAlertDestIPAddr attribute

Description Sets the IP address that receives the alert.

Legal Values A string representing a valid IP address. For example, 192.168.0.20.

Default None

cfgTrapsCommunityName (Read or Write)

Table 200. Details of cfgTrapsCommunityName attribute

Description Sets the community string (identical to the community name) used for authentication. The community string acts as a password shared between different hosts over the network. This community string value must match with the other hosts for any kind of communication through SNMP.

Legal Values A string representing the community name.

Default None

114 CMC Property Database Group and Object Descriptions

Page 115: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example

racadm getconfig -g cfgTraps -i 2# cfgTrapsIndex=2cfgTrapsEnable=1cfgTrapsAlertDestIpAddr=cfgTrapsCommunityName=public

cfgTrapsSNMPv3UserId (Read Only)

Table 201. Details of cfgTrapsSNMPv3UserId attribute

Description Displays the SNMP user ID of an existing CMC user.

Legal Values 1-16

Default Empty

cfgTrapsSNMPv3UserName

Table 202. Details of cfgTrapsSNMPv3UserName attribute

Description Configure SNMPv3 user name.

Legal Values Any existing CMC user name.

Default Empty

cfgRacTuningThis group is used to configure various configuration properties, such as valid ports and security port restrictions.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

The following sections provide information about the objects in the cfgRacTuning group.

NOTE: Only the following objects are displayed, if —m option is used:

• cfgRacTuneWebserverEnable• cfgRacTuneHttpPort• cfgRacTuneHttpsPort• cfgRacTuneTelnetPort• cfgRacTuneSshPort

CMC Property Database Group and Object Descriptions 115

Page 116: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRacTuneSMBVersionEnable

Table 203. Details of cfgUseCMCDNSSettings attribute

DescriptionCan be used for setting the SMB version.

Legal Values • SMBv1

• SMBv2

• SMBv3

• 1

• 2

• 3

Default NA

cfgRacTuneRemoteRacadmEnable (Read or Write)

Table 204. Details of cfgRacTuneRemoteRacadmEnable attribute

Description Enables or disables the Remote RACADM interface.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 1

cfgRacTuneIdracDNSLaunchEnable (Read or Write)

Table 205. Details of cfgRacTuneIdracDNSLaunchEnable attribute

Description Configure iDRAC or CMC GUI launch using IP or DNS.

Legal Values • 1 — Enabled (launch iDRAC or CMC using DNS name)

• 0 — Disabled (launch iDRAC or CMC using IP address)

Default 0 — Disabled

cfgRacTuneEnhancedLog (Read or Write)

Table 206. Details of cfgRacTuneEnhancedLog attribute

Description Enables or disables the enhanced chassis log feature.

Legal Values • 1 — Enable

116 CMC Property Database Group and Object Descriptions

Page 117: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• 0 — Disable

Default 0

cfgRacTuneHttpPort (Read or Write)

Table 207. Details of cfgRacTuneHttpPort attribute

Description To use HTTP network communication, specify the port number.

Legal Values 10–65535

NOTE: The following port numbers are reserved and cannot be used: 21, 68, 69, 111, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, and 60106.

Default 80

cfgRacTuneHttpsPort (Read or Write)

Table 208. Details of cfgRacTuneHttpsPort attribute

Description To use HTTPS network communication, specify the port number.

Legal Values 10–65535

NOTE: The following port numbers are reserved and cannot be used: 21, 68, 69, 111, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, and 60106.

Default 443

cfgRacTuneIpRangeEnable (Read or Write)

Table 209. Details of cfgRacTuneIpRangeEnable attribute

Description Enables or disables the IPv4 Address Range validation feature.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

CMC Property Database Group and Object Descriptions 117

Page 118: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRacTuneIpRangeAddr (Read or Write)

Table 210. Details of cfgRacTuneIpRangeAddr attribute

Description Specifies the acceptable IPv4 address bit pattern in the positions of the "1"s in the range mask property (cfgRacTuneIpRangeMask).

Alogin from the incoming IP address is allowed only if the following are identical:

• cfgRacTuneIpRangeMask bit-wise and with incoming IP address

• cfgRacTuneIpRanbeMask bit-wise and with cfgRacTuneIpRangeAddr

Legal Values An IPv4 address formatted string, for example, 192.168.0.

Default 192.168.0

cfgRacTuneIpRangeMask (Read or Write)

Table 211. Details of cfgRacTuneIpRangeMask attribute

Description Standard IP mask values with left-justified bits. For example, 255.255.255.0.

Login from the incoming IP address is allowed only if both of the following are identical:

• cfgRacTuneIpRangeMask bit-wise and with incoming IP address

• cfgRacTuneIpRanbeMask bit-wise and with cfgRacTuneIpRangeAddr

Legal Values An IPv4 address formatted string, for example, 255.255.255.0.

Default 255.255.255.0

cfgRacTuneIpBlkEnable (Read or Write)

Table 212. Details of cfgRacTuneIpBlkEnable attribute

Description Enables or disables the IPv4 address blocking feature.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

118 CMC Property Database Group and Object Descriptions

Page 119: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRacTuneIpBlkFailCount (Read or Write)

Table 213. Details of cfgRacTuneIpBlkFailCount attribute

Description The maximum number of logins that is not successful, to occur within the window (cfgRacTuneIpBlkFailWindow) before log in attempt from the IP address is rejected.

Legal Values 3–16

Default 5

cfgRacTuneIpBlkFailWindow (Read or Write)

Table 214. Details of cfgRacTuneIpBlkFailWindow attribute

Description Defines the time span in seconds that the unsuccessful attempts are counted. When unsuccessful attempts age beyond this limit, they are dropped from the count.

Legal Values 2–655356

Default 60

cfgRacTuneIpBlkPenaltyTime (Read or Write)

Table 215. Details of cfgRacTuneIpBlkPenaltyTime attribute

Description Defines the time span in seconds that session requests from an IP address with excessive failures are rejected.

Legal Values 2–655356

Default 300

cfgRacTuneDefCredentialWarningEnable (Read or Write)

Table 216. Details of cfgRacTuneDefCredentialWarningEnable attribute

Description Displays warning during login if the default credentials warning property is set.

NOTE: Warning is displayed only with configure the user privilege.

Legal Values • 1 — Enabled

• 0 — Disabled

Default 1 — Enabled

CMC Property Database Group and Object Descriptions 119

Page 120: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRacTuneUserBlkEnable (Read or Write)

Table 217. Details of cfgRacTuneUserBlkEnable attribute

Description Blocks the login for maximum of 5 minutes after 5 unsuccessful login attempts. The login using any interface such as WSMAN or GUI is blocked after 5 unsuccessful attempts

NOTE: This is applicable only to configure the user privilege.

Legal Values • 1 — Enabled

• 0 — Disabled

Default 0 — Disabled

cfgRacTuneSshPort (Read or Write)

Table 218. Details of cfgRacTuneSshPort attribute

Description Specifies the port number used for the SSH interface.

NOTE: The following port numbers are reserved and cannot be used: 21, 68, 69, 111, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, and 60106.

Legal Values 10–65535

Default 22

cfgRacTuneTelnetPort (Read or Write)

Table 219. Details of cfgRacTuneTelnetPort attribute

Description Specifies the port number used for the Telnet interface.

NOTE: The following port numbers are reserved and cannot be used: 21, 68, 69, 111, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, and 60106.

Legal Values 10–65535

Default 23

120 CMC Property Database Group and Object Descriptions

Page 121: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRacTuneDaylightOffset (Read Only)

Table 220. Details of cfgRacTuneDaylightOffset attribute

Description Specifies the daylight savings offset (in minutes) to use for the RAC Time. This value is 0 if the time zone is not a Daylight Saving time zone.

Legal Values 0–60

Default 0

Example

racadm getconfig -g cfgRacTuning [-m server-<n>] -o<object name> <object value>cfgRacTuneRemoteRacadmEnable=1cfgRacTuneWebserverEnable=1cfgRacTuneHttpPort=80cfgRacTuneHttpsPort=443cfgRacTuneTelnetPort=23cfgRacTuneSshPort=22cfgRacTuneIpRangeEnable=0cfgRacTuneIpRangeAddr=192.168.1.1cfgRacTuneIpRangeMask=255.255.255.0# cfgRacTuneTimezoneOffset=-18000# cfgRacTuneDaylightOffset=3600

cfgRacTuneTimezoneOffset (Read Only)

Table 221. Details of cfgRacTuneTimezoneOffset attribute

Description This object property is read only. Specifies the difference in number of seconds, from the UTC/GMT. This value is negative if the current time zone is west of Greenwich.

Legal Values None

Default 0

Example

racadm getconfig -g cfgRacTuningcfgRacTuneRemoteRacadmEnable=1cfgRacTuneWebserverEnable=1cfgRacTuneHttpPort=80cfgRacTuneHttpsPort=443cfgRacTuneTelnetPort=23cfgRacTuneSshPort=22cfgRacTuneIpRangeEnable=0cfgRacTuneIpRangeAddr=192.168.1.1cfgRacTuneIpRangeMask=255.255.255.0# cfgRacTuneTimezoneOffset=-18000# cfgRacTuneDaylightOffset=3600

CMC Property Database Group and Object Descriptions 121

Page 122: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRacTuneWebserverEnable (Read or Write)

Table 222. Details of cfgRacTuneWebserverEnable attribute

Description Enables or disables the web server. If this property is disabled then it is not accessible using client web browsers. This property has no effect on the Telnet/SSH or racadm interfaces.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 1

cfgRacTuneFipsModeEnable

Table 223. Details of cfgRacTuneFipsModeEnable attribute

Description Enables or disables the FIPS mode.

Legal Values 0 and 1

Default 0

Usage racadm getconfig -g cfgRacTuning -o cfgRacTuneFipsModeEnableracadm config -g cfgRacTuning -o cfgRacTuneFipsModeEnable 1

NOTE: The firmware racadm prompts you to confirm whether the FIPS mode has to be enabled, but remote racadm does not prompt you to do so.

cfgRacTuneTLSProtocolVersionEnable

Table 224. Details of cfgRacTuneTLSProtocolVersionEnable attribute

Description Sets the minimum TLS protocol version.

Legal Values • 0 - TLSv1.0, TLSv1.1, and TLSv1.2 are enabled.

• 1 - TLSv1.1 and TLSv1.2 are enabled.

• 2 - only TLSv1.2 is enabled.

Default 1

cfgServerInfoThis group allows you to display and configure a server in the chassis.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

122 CMC Property Database Group and Object Descriptions

Page 123: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: You can configure a setting does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option

The following sections provide information about the objects in the cfgServerInfo.

cfgServerInfoIndex (Read Only)

Table 225. Details of cfgServerInfoIndex attribute

Description Displays the index name of the server.

Legal Values None

Default None

cfgServerSlotNumber (Read Only)

Table 226. Details of cfgServerSlotNumber attribute

Description Specifies the location of the specified server (1–16) in the chassis.

Specify '-i nx' for HiFi blade information, where index-1 is a multi server sleeve.

For example, -i 1a

Legal Values None

Default None

cfgServerServiceTag (Read Only)

Table 227. Details of cfgServerServiceTag attribute

Description Displays the service tag of the specified server.

Legal Values None

Default None

cfgServerName (Read Or Write)

Table 228. Details of cfgServerName attribute

Description Displays the name of the specified server.

Legal Values Maximum of 15 non-extended (ASCII characters (ASCII codes 32 through 126). For more information, see Guidelines to Quote Strings Containing Special Characters.

Default SLOT — <slot number>

CMC Property Database Group and Object Descriptions 123

Page 124: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgServerFW (Read Only)

Table 229. Details of cfgServerFW attribute

Description Displays the server's iDRAC firmware revision.

Legal Values None

Default None

cfgServerBIOS (Read Only)

Table 230. Details of cfgServerBIOS attribute

Description Displays the server's BIOS revision.

Legal Values None

Default None

cfgServerBmcMacAddress (Read Only)

Table 231. Details of cfgServerBmcMacAddress attribute

Description Displays the BMC MAC address of the specified server.

Legal Values None

Default None

cfgServerNic1MacAddress (Read Only)

Table 232. Details of cfgServerNic1MacAddress attribute

Description Displays the MAC address of the server NIC 1.

Legal Values None

Default None

124 CMC Property Database Group and Object Descriptions

Page 125: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgServerNic2MacAddress (Read Only)

Table 233. Details of cfgServerNic2MacAddress attribute

Description Displays the MAC address of the server NIC 2.

Legal Values None

Default None

cfgServerPriority (Read or Write)

Table 234. Details of cfgServerPriority attribute

Description Sets the priority level allotted to the server in the chassis for power budgeting purposes.

Legal Values 1–9 in descending priority, where 1 holds the highest priority

Default 1

NOTE: You can set the cfgServerPriority for a slot using quarter-width blade servers. For example: config -g cfgserverinfo -o cfgserverpriority -i 6a 9

cfgServerNicEnable (Read or Write)

Table 235. Details of cfgServerPriority attribute

Description Enables or disables LAN channel.

Legal Values • 1 — Enable

• 0 — Disable

Default None

cfgServerIPMIOverLanEnable (Read or Write)

Table 236. Details of cfgServerIPMIOverLanEnable attribute

Description Enables or disables IPMI LAN channel.

Legal Values • 1 — Enable

• 0 — Disable

Default None

CMC Property Database Group and Object Descriptions 125

Page 126: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgServerPowerBudgetAllocation (Read Only)

Table 237. Details of cfgServerPowerBudgetAllocation attribute

Description Displays the current power allocation for the server.

Legal Values None

Default None

cfgServerDNSRegisterIMC (Read or Write)

Table 238. Details of cfgServerDNSRegisterIMC attribute

Description Enables or disables DNS name registration for iDRAC or IMC .

Legal Values • 1 — Enable

• 0 — Disable

Default None

cfgServerDNSIMCName (Read or Write)

Table 239. Details of cfgServerDNSIMCName attribute

Description Displays the DNS domain name for iDRAC or IMC.

Legal Values A valid string values

Default None

cfgServerRootPassword (Write Only)

Table 240. Details of cfgServerRootPassword attribute

Description Displays the password for IMC as a series of asterisks (*). It cannot be seen or displayed after this property is written.

Legal Values None

Default None

126 CMC Property Database Group and Object Descriptions

Page 127: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgServerFirstBootDevice (Read or Write)

Table 241. Details of cfgServerFirstBootDevice attribute

Description Sets or displays the first boot device.

NOTE: First attach, to configure vFlash as First Boot Device. When a detached or non-existent vFlash partition or a nonstandard boot device is configured as first boot device, the following error message is displayed:

Invalid object value

Legal Values • No-Override

• PXE

• HDD

• CD-DVD

• BIOS

• vFDD

• VCD-DVD

• iSCSI

• VFLASH partition label

• FDD

• SDe

• RFS (Remote File Share)

Default No-Override

cfgServerBootOnce (Read or Write)

Table 242. Details of cfgServerBootOnce attribute

Description Enables or disables the server start once feature.

This object is Write only.

Legal Values • 1 — True

• 0 — False

Default 1

cfgServerPowerConsumption (Read Only)

Table 243. Details of cfgServerPowerConsumption attribute

Description Displays the current power consumption for a server.

Legal Values None

Default None

CMC Property Database Group and Object Descriptions 127

Page 128: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example

racadm getconfig -g cfgServerInfo -i 1a

# cfgServerInfoIndex=1a

# cfgServerSlotNumber=1a

# cfgServerServiceTag=ABC1234

cfgServerName=SLOT-01a

# cfgServerFW=1.57.57 (Build 04)

# cfgServerBIOS=2.3.3

# cfgServerBmcMacAddress=F8:DB:88:3E:1A:00

# cfgServerNic1MacAddress=F8:DB:88:3E:1A:01

# cfgServerNic2MacAddress=F8:DB:88:3E:1A:04

cfgServerPriority=1

cfgServerNicEnable=0

cfgServerIPMIOverLANEnable=0

# cfgServerPowerBudgetAllocation=246

cfgServerDNSRegisterIMC=0

cfgServerDNSIMCName=idrac-ABCD1234

# cfgServerRootPassword=******** (Write-Only)

cfgServerFirstBootDevice=0

cfgServerBootOnce=1

# cfgServerPowerConsumption=84

cfgActiveDirectoryThis group contains parameters to configure CMC Active Directory feature.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

The following sections provide information about the objects in the cfgActiveDirectory.

128 CMC Property Database Group and Object Descriptions

Page 129: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgADRacDomain (Read or Write)

Table 244. Details of cfgADRacDomain attribute

Description Active Directory Domain in which CMC resides.

Legal Values Any printable text string of up to 254 characters, with no white space.

Default <blank>

cfgADRacName (Read or Write)

Table 245. Details of cfgADRacName attribute

Description Name of CMC as recorded in the Active Directory forest.

Legal Values Any printable text string of up to 254 characters, with no white space.

Default <blank>

cfgADRootDomain (Read or Write)

Table 246. Details of cfgADRootDomain attribute

Description Specifies the root domain of the domain forest.

Legal Values Any printable text string of up to 254 characters, with no white space.

Default <blank>

cfgADEnable (Read or Write)

Table 247. Details of cfgADEnable attribute

Description Enables or disables Active Directory user authentication on CMC.

If this property is disabled then either local CMC or LDAP authentication may be used for user login.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

CMC Property Database Group and Object Descriptions 129

Page 130: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgADSCLEnable (Read or Write)

Table 248. Details of cfgADSCLEnable attribute

Description Enables or disables Smart Card login on CMC.

Legal Values • 1 (Enable)

• 0 (Disable)

Default 0

cfgADSSOEnable (Read or Write)

Table 249. Details of cfgADSSOEnable attribute

Description Enables or disables Active Directory single sign-on authentication on CMC.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

cfgADDomainController (Read or Write)

Table 250. Details of cfgADDomainController attribute

Description To obtain user names, specify the AD server from which you want the CMC. It must be used with cfgADSpecifyServerEnable.

Legal Values Valid IP address or fully qualified domain name (FQDN).

Default None

cfgADAuthTimeout (Read or Write)

Table 251. Details of cfgADAuthTimeout attribute

Description To wait for Active Directory authentication requests to complete before timing out, specify the number of seconds.

Legal Values 15–300 seconds

Default 120

130 CMC Property Database Group and Object Descriptions

Page 131: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgADType (Read or Write)

Table 252. Details of cfgADType attribute

Description To use the Active Directory, determine the schema type.

Legal Values • 1— (Enables Active Directory with the extended schema)

• 2— (Enables Active Directory with the standard schema)

Default 1

cfgADSpecifyServerEnable (Read or Write)

Table 253. Details of cfgADSpecifyServerEnable attribute

Description Allows you to enable or disable and specify an LDAP server or a global catalog server. To specify the IP address, use either cfgADDomainController or cfgADGlobalCatalog.

Legal Values • 1 (enabled)

• 0 (disabled)

Default 0

cfgADGlobalCatalog (Read or Write)

Table 254. Details of cfgADGlobalCatalog attribute

Description To obtain user names, specify the Global Catalog server from which you want the CMC. It must be used with cfgADSpecifyServerEnable.

Legal Values Valid IP address or fully qualified domain name (FQDN)

Default None

Example

racadm getconfig -g cfgActiveDirectorycfgADEnable=0cfgADSCLEnable=0cfgADSSOEnable=0cfgADRacDomain=cfgADRootDomain=helpcfgADRacName=cfgADCertValidationEnable=1cfgADRacAuthTimeout=120cfgADType=1cfgADSpecifyServerEnable=0cfgADDomainController=cfgADGlobalCatalog=

CMC Property Database Group and Object Descriptions 131

Page 132: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgADCertValidationEnable (Read or Write)

Table 255. Details of cfgADCertValidationEnable attribute

Description Enables or disables Active Directory certificate validation as a part of the Active Directory configuration process.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 1

cfgLDAPThis group allows you to configure settings related to the Lightweight Directory Access Protocol (LDAP).

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

The following sections provide information about the objects in the cfgLDAP.

cfgLDAPEnable (Read or Write)

Table 256. Details of cfgLDAPEnable attribute

Description Enables or disables LDAP service.

If this property is disabled, local CMC authentication is used for user logins.

NOTE: Enabling this option turns off cfgADEnable.

Legal Values • 1 — Enable

• 0 — Disable

Default 0

cfgLDAPServer (Read or Write)

Table 257. Details of cfgLDAPServer attribute

Description Configures the address of the LDAP Server. IPv4 and IPv6 are supported.

NOTE: You can specify multiple servers by separating each server with a comma. For example, example.com, sub1.example.com

Legal Values String.

132 CMC Property Database Group and Object Descriptions

Page 133: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Maximum length = 254

Default Null

cfgLDAPPort (Read or Write)

Table 258. Details of cfgLDAPPort attribute

Description Port of LDAP over SSL. Non-SSL port is not supported.

Legal Values 1–65535

Default 636

cfgLDAPBaseDN (Read or Write)

Table 259. Details of cfgLDAPBaseDN attribute

Description The domain name of the branch of the directory where all searches must start.

Legal Values String. Maximum length = 254

Default Null

cfgLDAPUserAttribute (Read or Write)

Table 260. Details of cfgLDAPUserAttribute attribute

Description To search for, specify the user attribute. It is recommended to be unique within the chosen baseDN, otherwise a search filter must be configured to make sure the uniqueness of the login user. If the userDN cannot be uniquely identified, login is unsuccessful with error.

Legal Values String. Maximum length = 254

Default Null

cfgLDAPGroupAttribute (Read or Write)

Table 261. Details of cfgLDAPGroupAttribute attribute

Description Specifies which LDAP attribute is used to check for group membership. It must be an attribute of the group class. If not specified then the member and unique member attributes are used.

Legal Values String maximum length = 254

Default Null

CMC Property Database Group and Object Descriptions 133

Page 134: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgLDAPGroupAttributeIsDN (Read or Write)

Table 262. Details of cfgLDAPGroupAttributeIsDN attribute

Description If enabled, the CMC performs DN matching, otherwise the CMC uses the user name provided at login for matching.

Legal Values • 1(TRUE) — Use the userDN from the LDAP Server

• 0(FALSE) — Use the userDN to provide the login user

Default 1

cfgLDAPBindDN (Read or Write)

Table 263. Details of cfgLDAPBindDN attribute

Description The distinguished name of a user used to bind to the server when searching for the login user's DN. If not provided, an anonymous bind is used. If necessary It is optional to support anonymous bind.

NOTE: If cfgLDAPBindDN is [null] and cfgLDAPBindPassword is [null], then the CMC attempts an anonymous bind.

Legal Values String maximum length = 254

Default Null

cfgLDAPBindPassword (Write Only)

Table 264. Details of cfgLDAPBindPassword attribute

Description A bind password is used with the bindDN. The bind password is a sensitive data, and must be protected. It is optional to support anonymous bind.

Legal Values String maximum length = 254

Default Null

cfgLDAPSearchFilter (Read or Write)

Table 265. Details of cfgLDAPSearchFilter attribute

Description To validate LDAP search filter, use the user attribute that cannot uniquely identify the login user within the chosen baseDN. The search filter only applies to userDN search and not the group membership search.

Legal Values String of maximum length = 1024 characters

Default (objectless=*)

134 CMC Property Database Group and Object Descriptions

Page 135: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Searches for all objects in tree.

cfgLDAPCertValidationEnable (Read or Write)

Table 266. Details of cfgLDAPCertValidationEnable attribute

Description Controls certificate validation during SSL handshake.

Legal Values • 1 (TRUE) — Uses the CA certificate to validate the LDAP server certificate during SSL handshake.

• 0 (FALSE) —Skips the certificate validation step of SSL handshake.

Default 1

cfgLDAPNetworkTimeout (Read or Write)

Table 267. Details of cfgLDAPNetworkTimeout attribute

Description Configures the network timeout in seconds.

Legal Values Positive integer

Default 30 seconds

cfgLDAPSearchTimeout (Read or Write)

Table 268. Details of cfgLDAPSearchTimeout attribute

Description Configures the search timeout in seconds.

Legal Values Positive integer

Default 120 seconds

cfgLDAPSRVLookupEnable (Read or Write)

Table 269. Details of cfgLDAPSRVLookupEnable attribute

Description To query a DNS server for SRV records, Configure the CMC.

Legal Values • 1 — True

• 0 — False

Default 0

CMC Property Database Group and Object Descriptions 135

Page 136: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgLDAPSRVLookupDomainName (Read Only)

Table 270. Details of cfgLDAPSRVLookupDomainName attribute

Description To use in the SRV lookup, configure the domain name.

Legal Values String of maximum length of 254 alphanumeric characters and hyphens. The string must begin with a letter.

Default [null]

cfgLDAPSRVLookupServiceName (Read or Write)

Table 271. Details of cfgLDAPSRVLookupServiceName attribute

Description To use in the SRV lookup, configure the service name.

Legal Values String of maximum length of 254 characters.

Default LDAP

cfgLDAPRoleGroupThis group configures Generic LDAP Role group descriptions and defines the CMC privileges that LDAP-authenticated users are granted.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

cfgLDAPRoleGroup is indexed, containing instances numbered from 1 to 5. Each object instance consists of a pair of properties:

• cfgLDAPRoleGroupDN — an LDAP distinguished name (DN)

• cfgLDAPRoleGroupPrivilege — a CMC privilege map

Each LDAP-authenticated user assumes the total set of CMC privileges assigned to the matching LDAP distinguished names that the user belongs to. That is, if the user belongs to multiple role group DNs, the user receives all associated privileges for that DNs.

The following sections provide information about the objects in the cfgLdapRoleGroup.

cfgLDAPRoleGroupIndex (Read Only)

Table 272. Details of cfgLDAPRoleGroupIndex attribute

Description It is the index value of the Role Group Object.

Legal Values An integer between 1 and 5

Default <instance>

136 CMC Property Database Group and Object Descriptions

Page 137: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgLDAPRoleGroupDN (Read or Write)

Table 273. Details of cfgLDAPRoleGroupDN attribute

Description It is the Domain Name of the group in this index.

Configure the LDAP distinguished name (DN) for the role group instance.

Legal Values String maximum length = 1024

Default None

Example

racadm getconfig -g cfgLDAPRoleGroup -o cfgLDAPRoleGroupDN -i 1 <everyone> <groups> <openldap> <com>

cfgLDAPRoleGroupPrivilege (Read or Write)

Table 274. Details of cfgLDAPRoleGroupPrivilege attribute

Description A bit–mask defining the privileges associated with this particular group.

Legal Values 0x00000000 to 0x000001ff

Default 0x000

Example

racadm getconfig -g cfgLDAPRoleGroup -o cfgLDAPRoleGroupPrivilege -i 1 0x000001ff

cfgStandardSchemaThis group contains parameters to configure the Active Directory standard schema settings.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

NOTE: You can configure a setting that does not have hash sign (#) prefixed in the output. To modify a configurable object, use the —o option.

The following sections provide information about the objects in the cfgStandardSchema.

CMC Property Database Group and Object Descriptions 137

Page 138: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgSSADRoleGroupIndex (Read Only)

Table 275. Details of cfgSSADRoleGroupIndex attribute

Description Index of the Role Group as recorded in the Active Directory.

Legal Values An integer from 1 to 5

Default <instance>

cfgSSADRoleGroupName (Read or Write)

Table 276. Details of cfgSSADRoleGroupName attribute

Description Name of the Role Group as recorded in the Active Directory forest.

Legal Values Any printable text string of up to 254 characters, with no white space.

Default <blank>

cfgSSADRoleGroupDomain (Read or Write)

Table 277. Details of cfgSSADRoleGroupDomain attribute

Description Active Directory Domain in which the Role Group resides.

Legal Values Any printable text string of up to 254 characters, with no white space.

Default <blank>

cfgSSADRoleGroupPrivilege (Read or Write)

Table 278. Details of cfgSSADRoleGroupPrivilege attribute

Description Use the bit mask numbers listed in the table below to set role-based authority privileges for a Role Group.

Legal Values 0x00000000 to 0x000001ff

Default <blank>

cfgLocationThis group defines objects that support physical location properties. Use this object with the config or getconfig subcommands.

138 CMC Property Database Group and Object Descriptions

Page 139: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

To use this object property, you must have the Chassis Configuration Administrator privilege.

cfgLocationDataCenter (Read or Write)

Table 279. Details of cfgLocationDataCenter attribute

Description Indicates data center name.

Legal Values String of up to 128 ASCII characters

Default 0

cfgLocationAisle (Read or Write)

Table 280. Details of cfgLocationAisle attribute

Description Indicates aisle where server is located.

Legal Values String of up to 128 ASCII characters

Default 0

cfgLocationRack (Read or Write)

Table 281. Details of cfgLocationRack attribute

Description Indicates rack where server is located.

Legal Values String of up to 128 ASCII characters

Default 0

cfgLocationRackslot (Read or Write)

Table 282. Details of cfgLocationRackslot attribute

Description Indicates slot where server is located.

Legal Values Values 1–255 (1 Byte)

Default 0

CMC Property Database Group and Object Descriptions 139

Page 140: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgLocationDeviceSize (Read Only)

Table 283. Details of cfgLocationDeviceSize attribute

Description Indicates server chassis size.

Legal Values Values 1–255

Default 0

cfgChassisPowerThis group contains parameters to display or configure power for the chassis.

Use this object with the config or getconfig subcommands.

To use this object property, you must have the Chassis Configuration Administrator privilege.

NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable object, use the -o option.

The following sections provide information about the objects in the cfgChassisPower group.

NOTE: When updating from a file, update the value for one chassis power cap property and remove the values for the other chassis power cap properties or, update the last percentage value as it is applicable to all chassis power cap properties. The chassis power cap properties are: cfgChassisPowerCap, cfgChassisPowerCapF, cfgChassisPowerCapBTU, cfgChassisPowerCapFBTU, cfgChassisPowerCapPercent, and cfgChassisPowerCapFPercent.

cfgChassisServerBasedPowerMgmtMode (Read or Write)

Table 284. Details of acfgChassisServerBasedPowerMgmtMode ttribute

Description Manages the applicable functions by the Power Measure, Mitigate, and Manage Console (PM3).

Legal Values • 1 — Enabled

• 0 — Disabled

Default 0 — Disabled

cfgChassisEPPEnable (Read or Write)

Table 285. Details of cfgChassisEPPEnable attribute

Description Enables the Extended Power Performance (EPP).

Legal Values • 1 — Enabled• 0 — Disabled

Default 0 — Disabled

140 CMC Property Database Group and Object Descriptions

Page 141: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

NOTE: For chassis with 3000W AC six PSU configuration (configured for Grid Redundancy policy), the default value is 1–Enabled.

cfgChassisInPower (Read Only)

Table 286. Details of cfgChassisInPower attribute

Description Indicates the cumulative input power consumption data (in watts and BTU/hr) captured from all healthy and functional PSUs in the chassis.

Legal Values None

Default None

cfgChassisPeakPower (Read Only)

Table 287. Details of cfgChassisPeakPower attribute

Description Since the user has cleared last value, the system power consumption (in watts) is maximum.

Legal Values None

Default None

cfgChassisPeakPowerTimestamp (Read Only)

Table 288. Details of acfgChassisPeakPowerTimestamp ttribute

Description The timestamp recorded when the peak input power consumption value occurred.

Legal Values None

Default None

cfgChassisMinPower (Read Only)

Table 289. Details of cfgChassisMinPower attribute

Description Since the user has cleared last value, the system power consumption (in watts) is maximum.

Legal Values None

Default None

CMC Property Database Group and Object Descriptions 141

Page 142: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgChassisMinPowerTimestamp (Read Only)

Table 290. Details of cfgChassisMinPowerTimestamp attribute

Description The timestamp recorded when the minimum system power occurred.

Legal Values None

Default None

cfgChassisPowerStatus (Read Only)

Table 291. Details of cfgChassisPowerStatus attribute

Description Indicates the power status of the chassis.

Legal Values • 1 — (other)

• 2 — (unknown)

• 3 — (OK)

• 4 — (noncritical)

• 5 — (critical)

• 6 — (nonrecoverable)

Default None

cfgChassisRedundantState (Read or Write)

Table 292. Details of cfgChassisRedundantState attribute

Description Enables or disables power redundancy for the chassis.

Legal Values • 0 — No Redundancy

• 1 — Grid Redundancy

• 2 — PSU Redundancy

Default 0

cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)

Table 293. Details of cfgChassisDefaultPowerCapLowerBoundBTU attribute

Description Displays the default power cap lower bound value using British Thermal Unit (BTU).

Legal Values None

142 CMC Property Database Group and Object Descriptions

Page 143: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Default 9263 BTU/h

cfgChassisDefaultPowerCapLowerBound (Read Only)

Table 294. Details of cfgChassisDefaultPowerCapLowerBound attribute

Description Displays the default power cap lower bound value.

Legal Values None

Default 2715 W

cfgChassisDefaultPowerCapUpperBound (Read Only)

Table 295. Details of cfgChassisDefaultPowerCapUpperBound attribute

Description Displays the default power cap upper bound value.

Legal Values None

Default 16685 W

cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)

Table 296. Details of cfgChassisDefaultPowerCapUpperBoundBTU attribute

Description Displays the default power cap upper bound value using British Thermal Unit (BTU).

Legal Values None

Default 56931 BTU/h

cfgChassisPowerCap (Read or Write)

Table 297. Details of cfgChassisPowerCap attribute

Description Indicates the maximum power consumption limit (in watts) for the entire chassis. The command generates an error if server throttling is necessary to achieve the power goal based on the value for this setting.

Legal Values 2715–16685 watts

Default 16685 watts

CMC Property Database Group and Object Descriptions 143

Page 144: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgChassisPowerCapF (Read or Write)

Table 298. Details of cfgChassisPowerCapF attribute

Description Indicates the maximum power consumption limit (in watts) for the entire chassis. Use cfgChassisPowerCapF when power consumption changes regardless of whether server throttling is required. This command generates an error if the value for this setting is lower than the minimum power required for the chassis configuration.

Legal Values 271–16685 watts

Default 16685 watts

cfgChassisPowerCapBTU (Read or Write)

Table 299. Details of cfgChassisPowerCapBTU attribute

Description Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. The command generates an error if server throttling is necessary to achieve the power goal based on the value for this setting.

Legal Values 9264–56931 BTU/hr

Default 43221 BTU/hr

cfgChassisPowerCapFBTU (Read or Write)

Table 300. Details of cfgChassisPowerCapFBTU attribute

Description Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. Use cfgChassisCapFBTU when power consumption changes regardless of whether server throttling is required. The command generates an error if the value for this setting is lower than the minimum power required for the chassis configuration.

Legal Values 9264–56931 BTU/hr

Default 56931 BTU/hr

cfgChassisPowerCapPercent (Read or Write)

Table 301. Details of cfgChassisPowerCapPercent attribute

Description Indicates the power consumption limit as a percentage. The percentage is computed mathematically as the minimum power + (percent * (maximum power — minimum power)). The command generates an error if server throttling is necessary to achieve the power goal based on the value for this setting.

Legal Values 16–100

NOTE: If the specified percent is lower than the minimum value, the CMC sets the value to the minimum value.

144 CMC Property Database Group and Object Descriptions

Page 145: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Default 100

cfgChassisPowerCapFPercent (Read or Write)

Table 302. Details of cfgChassisPowerCapFPercent attribute

Description Indicates the power consumption limit as a percentage. The percentage is computed mathematically as the minimum power + (percent * (maximum power — minimum power)). Use cfgChassisPowerCapFPercent when power consumption is changes regardless of whether server throttling is required.

Legal Values 16–100

NOTE: If the specified percent is lower than the minimum value, the CMC sets the value to the minimum value.

Default 100

cfgChassisRedundancyPolicy (Read or Write)

Table 303. Details of cfgChassisRedundancyPolicy attribute

Description Sets the redundancy policy of the chassis.

Legal Values • 0 — No redundancy

• 1 — Grid redundancy

• 2 — Power supply redundancy

Default 0 — No redundancy

cfgChassisDynamicPSUEngagementEnable (Read or Write)

Table 304. Details of cfgChassisDynamicPSUEngagementEnable attribute

Description Enables or disables dynamic engagement.

Legal Values • 0 — Disabled

• 1 — Enabled

Default 0

CMC Property Database Group and Object Descriptions 145

Page 146: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgChassisAllow110VACOperation (Read or Write)

Table 305. Details of cfgChassisAllow110VACOperation attribute

Description Enables or disables normal chassis power allocations when any PSU is connected to 110V AC service. If disabled and 110V power supplies are detected, all subsequent server power allocation requests are denied. In this mode more servers cannot be powered on, regardless of server priority.

Legal Values • 0 — Disabled

• 1 — Enabled

Default 0

cfgChassisAllow110VACOperationTimestamp (Read Only)

Table 306. Details of cfgChassisAllow110VACOperationTimestamp attribute

Description The timestamp recorded when Allow110V setting from power management is enabled.

Legal Values

Default 0

cfgChassisMaxPowerConservationMode (Read or Write)

Table 307. Details of cfgChassisMaxPowerConservationMode attribute

Description Enables or disables maximum power conservation mode. When enabled, all servers are immediately reduced to their minimum power levels, and all subsequent server power allocation requests are denied. In this mode, performance of powered on servers may be degraded and more servers cannot be powered on, regardless of server priority.

Legal Values • 0 — Disabled

• 1 — Enabled

Default 0

cfgChassisMaxPowerConservationModeTimestamp (Read Only)

Table 308. Details of cfgChassisMaxPowerConservationModeTimestamp attribute

Description The timestamp recorded when maximum power conservation mode is enabled.

Legal Values

Default 0

146 CMC Property Database Group and Object Descriptions

Page 147: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgChassisPerformanceOverRedundancy (Read or Write)

Table 309. Details of cfgChassisPerformanceOverRedundancy attribute

Description Enables or disables server performance over power redundancy. When enabled, this option favors server performance and server power-up over maintenance of power redundancy. When disabled, the system favors power redundancy over server performance. If the power supply in the chassis does not provide sufficient power, both for redundancy, as well as full performance, then some servers may not grant sufficient power for full performance. In order to maintain redundancy, It may not be powered on.

Legal Values • 0 — Disabled

• 1 — Enabled

Default 0

cfgChassisInMaxPowerCapacity (Read Only)

Table 310. Details of cfgChassisInMaxPowerCapacity attribute

Description Indicates the total chassis power budget (in watts) available for chassis operation.

Legal Values None

Default None

cfgChassisInRedundancyReserve (Read Only)

Table 311. Details of cfgChassisInRedundancyReserve attribute

Description Indicates the amount of redundant power (in watts) in reserve that can be used in the event if an AC grid or PSU is unsuccessful. This value is 0 if the Redundancy Policy is set to 0 (no redundancy).

Legal Values 0 — (disabled)

1 — (enabled)

Default None

cfgChassisInPowerServerAllocation (Read Only)

Table 312. Details of cfgChassisInPowerServerAllocation attribute

Description Indicates (in watts) the cumulative power allocated to servers. There is no default as this parameter is specific to the particular customer configuration.

Legal Values None

CMC Property Database Group and Object Descriptions 147

Page 148: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Default None

cfgChassisInfrastructureInPowerAllocation (Read Only)

Table 313. Details of cfgChassisInfrastructureInPowerAllocation attribute

Description Indicates the estimated cumulative DC output power consumption (in watts), determined from a field replaceable unit (FRU) on the hardware modules in the chassis.

Legal Values None

Default None

cfgChassisTotalInPowerAvailable (Read Only)

Table 314. Details of cfgChassisTotalInPowerAvailable attribute

Description Indicates the amount of power (in watts) available for use by the chassis.

Legal Values None

Default None

cfgChassisStandbyInPowerCapacity (Read Only)

Table 315. Details of cfgChassisStandbyInPowerCapacity attribute

Description Indicates the amount of power (in watts) available for powering up any hardware modules that are either added to the chassis or powered up (if they are already present in the chassis).

Legal Values None

Default None

cfgChassisPowerClear (Write Only)

Table 316. Details of cfgChassisPowerClear attribute

Description Resets cfgChassisMinPower and cfgChassisMaxPowerCapacity, when set to 1.

Legal Values None

Default None

148 CMC Property Database Group and Object Descriptions

Page 149: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgChassisPowerClearTimestamp (Read Only)

Table 317. Details of cfgChassisPowerClearTimestamp attribute

Description Time stamp when cfgChassisMinPower and cfgChassisMaxPowerCapacity were reset.

Legal Values None

Default None

cfgChassisPowerButtonEnable (Read or Write)

Table 318. Details of cfgChassisPowerButtonEnable attribute

Description Indicates if the chassis power button is enabled or disabled.

Legal Values • 0 — Disabled

• 1 — Enabled

Default None

cfgSystemEnergyConsumptionClear (Write Only)

Table 319. Details of cfgSystemEnergyConsumptionClear attribute

Description Resets energy statistics when set to 1.

Legal Values None

Default None

Examples

• racadm getconfig -g cfgChassisPower# cfgChassisInPower=0 W | 0 BTU/hr# cfgChassisPeakPower=0 W# cfgChassisPeakPowerTimestamp=06:32:55 01/26/2009# cfgChassisMinPower=0 W# cfgChassisMinPowerTimestamp=06:32:55 01/26/2009# cfgChassisPowerStatus=5# cfgChassisRedundantState=0cfgChassisPowerCap=16685 WcfgChassisPowerCapF=16685 WcfgChassisPowerCapBTU=56931 BTU/hrcfgChassisPowerCapFBTU=56931 BTU/hrcfgChassisPowerCapPercent =100%cfgChassisPowerCapFPercent =100%cfgChassisRedundancyPolicy=0cfgChassisDynamicPSUEngagementEnable=0# cfgChassisInMaxPowerCapacity=0 W# cfgChassisInRedundancyReserve=0 W# cfgChassisInPowerServerAllocation=0 W# cfgChassisInfrastructureInPowerAllocation=51 W

CMC Property Database Group and Object Descriptions 149

Page 150: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

# cfgChassisTotalInPowerAvailable=0 W# cfgChassisStandbyInPowerCapacity=0 W# cfgChassisPowerClear=******** (Write-Only)# cfgChassisPowerClearTimestamp=18:00:00 12/31/1969cfgChassisServerBasedPowerMgmtMode=0cfgChassisPowerButtonEnable=1cfgChassisAllow110VACOperation=0cfgChassisMaxPowerConservationMode=0cfgChassisPerformanceOverRedundancy=1# cfgSystemEnergyConsumptionClear = ****(Write-Only)cfgChassisServerBasedPowerMgmtMode=0

• racadm config -g cfgChassisPower ‑o cfgChassisPowerClear 1Clears cfgChassisMinPower and cfgChassisPeakPower.

cfgChassisACPowerRecoveryDisable

Table 320. Details of cfgChassisACPowerRecoveryDisable attribute

Description If AC power recovery is disabled, the chassis is powered off after power outage is restored.

Legal Values • 0 — Enable

• 1 — Disable

Default 0

cfgThermalThis group displays and configures the thermal settings. Use this object with the config or getconfig subcommands.

To set the configurations, you must have the Chassis Configuration Administrator privileges.

cfgThermalMFSPercent (Read or Write)

Table 321. Details of cfgThermalMFSPercent attribute

Description Configures the minimum fan speed in percent.

Legal Values 0 to 100

Default 0

cfgThermalEnhancedCoolingMode (Read or Write)

Table 322. Details of cfgThermalEnhancedCoolingMode attribute

Description Configures the enhanced cooling mode.

Legal Values • 1 — Enabled

150 CMC Property Database Group and Object Descriptions

Page 151: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

• 0 — Disabled

Default 0 — Disabled

cfgKVMInfoThis group is used to display information for and configure the iKVM.

Use this object with the config or getconfig subcommands.

To use this object property, you must have Chassis Configuration Administrator privilege.

cfgKVMAccessToCMCEnable (Read or Write)

Table 323. Details of cfgKVMAccessToCMCEnable attribute

Description Enables or disables the Dell CMC Console access on the iKVM.

Legal Values • 1 (Enable)

• 0 (Disable)

Default None

cfgKVMFrontPanelEnable (Read or Write)

Table 324. Details of cfgKVMFrontPanelEnable attribute

Description Enables or disables front panel access on the iKVM.

Legal Values • 1 (enable)

• 0 (disable)

Default None

Example

racadm getconfig -g cfgKVMInfocfgKVMAccessToCMCEnable=1cfgKVMFrontPanelEnable=1

cfgLcdInfoThis group is used to display information for and configure the LCD.

To use this object property, you must have the Chassis Configuration Administrator privilege.

The following section provides information about the object in cfgLcdInfo.

CMC Property Database Group and Object Descriptions 151

Page 152: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgLcdLocale (Read or Write)

Table 325. Details of cfgLcdLocale attribute

Description Specifies the Language (locale) for the Blade Chassis LCD interface.

Legal Values de, fr, en, es, ja, zh-cn.

Default en

Example racadm config -g cfgLcdInfo -o cfgLcdLocale enObject value modified successfully.

cfgAlertingThis group enables or disables SNMP event trap alerting and sets the event filter.

Use this object with the config or getconfig subcommands.

cfgAlertingEnable (Read or Write)

Table 326. Details of cfgAlertingEnable attribute

Description Enables or disables event traps on the CMC.

Legal Values • 1 (true)

• 0 (false)

Default None

To use this object property, you must have Chassis Configuration Administrator privilege.

cfgAlertingFilterMask (Read or Write)

Table 327. Details of cfgAlertingFilterMask attribute

Description Sets the event filter.

Legal Values Hex values 0x0 — 0x1fffffff

Default 0x17ff8db

To use this object property, you must have Chassis Configuration Administrator privilege.

152 CMC Property Database Group and Object Descriptions

Page 153: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgAlertingSourceEmailName (Read Only)

Table 328. Details of cfgAlertingSourceEmailName attribute

Description Specifies the email address used to send email notifications when an event occurs.

Legal Values None

Default None

Examples

racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailNameracadm config -g cfgAlerting -o cfgAlertingSourceEmailName [email protected] value modified successfullyTo use this object property, you must have Chassis Configuration Administrator and Test Alert User privileges.

cfgIPv6LanNetworkingThis group is used to configure the IPv6 over LAN networking capabilities.

Use this object with the config or getconfig subcommands.

To use this object property, you must have Chassis Configuration Administrator privilege.

The following sections provide information about the objects in the cfgIPv6LanNetworking group.

cfgIPv6Enable (Read or Write)

Table 329. Details of cfgIPv6Enable attribute

Description Enables or disables CMC IPv6 stack.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 0

cfgIPv6Address (Read or Write)

Table 330. Details of cfgIPv6Address attribute

Description Assigns a static IPv6 address to the CMC. This property is used only if cfgIPv6AutoConfig is set to 0 (false).

Legal Values A string representing a valid IPv6 address. For example, 2001:DB8:1234:5678:9ABC:DE11:C00C:BEEF

CMC Property Database Group and Object Descriptions 153

Page 154: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Default “ :: “

cfgIPv6Gateway (Read or Write)

Table 331. Details of cfgIPv6Gateway attribute

Description CMC gateway IPv6 address.

NOTE: This property is used only if cfgIPv6AutoConfig is set to 0 (false).

Legal Values Specifies string representing a valid IPv6 entry.

Default “ :: “

cfgIPv6PrefixLength (Read or Write)

Table 332. Details of cfgIPv6PrefixLength attribute

Description Specifies the prefix length for IPv6 address.

NOTE:

• This property is used only if cfgIPv6AutoConfig is set to 0(false)

Legal Values 0–128

Default 64

cfgIPv6AutoConfig (Read or Write)

Table 333. Details of cfgIPv6AutoConfig attribute

Description Enables or disables the IPv6 Auto Configuration option.

NOTE: If this value is set to 0, the CMC disables auto configuration and statically assigns IPv6 addresses.

If this value is set to 1, the CMC obtains address and route information using stateless auto configuration and DHCPv6.

NOTE: The CMC uses its MAC address for its DUID (DUID-LL) when communicating with a DHCPv6 server.

Legal Values • 1 (TRUE)

• 0 (FALSE)

Default 1

154 CMC Property Database Group and Object Descriptions

Page 155: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgIPv6DNSServersFromDHCP6 (Read or Write)

Table 334. Details of cfgIPv6DNSServersFromDHCP6 attribute

Description Specifies whether cfgIPv6DNSServer1 and cfgIPv6DNSServer2 are static or DHCP IPv6 addresses.

NOTE: This property is used only if cfgIPv6AutoConfig is set to 1(true).

Legal Values 1 (TRUE)

0 (FALSE)

Default 1

cfgIPv6DNSServer1 (Read or Write)

Table 335. Details of cfgIPv6DNSServer1 attribute

Description Specifies the IPv6 DNS server address.

NOTE: This property is used only if cfgIPv6DNSServersFromDHCP6 is set to 0 (false).

Legal Values A string representing a valid IPv6 entry.

For example, 2001:DB8:1234:5678:9ABC:DE11:C00C:BEEF

Default “ :: “

cfgIPv6DNSServer2 (Read or Write)

Table 336. Details of cfgIPv6DNSServer2 attribute

Description Specifies the IPv6 DNS server address.

NOTE: This property is only valid if cfgIPv6DNSServersFromDHCP6 is set to 0 (false).

Legal Values A string representing a valid IPv6 entry. For example,

2001:DB8:1234:5678:9ABC:DE11:C00C:BEEF

Default “ :: ”

CMC Property Database Group and Object Descriptions 155

Page 156: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Example

$ racadm getconfig -g cfgIPv6LanNetworking cfgIPv6Enable=1cfgIPv6AutoConfig=1cfgIPv6Address=::cfgIPv6PrefixLength=64cfgIPv6Gateway=::cfgIPv6DNSServersFromDHCP6=1cfgIPv6DNSServer1=::cfgIPv6DNSServer2=::If both IPv4 and IPv6 are enabled on the CMC, IPv6 DNS servers take priority. The order of preference for DNS servers is:

• cfgIPv6DNSServer1 • cfgIPv6DNSServer2• cfgDNSServer1 • cfgDNSServer2

cfgCurrentLanNetworking (Read Only)This group displays the current CMC NIC properties.

Use this object with the getconfig subcommand.

To use this object property, you must have the CMC Login User privilege.

Synopsis

racadm getconfig -g cfgCurrentLanNetworking

cfgNicCurrentIpAddress (Read Only)

Table 337. Details of cfgNicCurrentIpAddress attribute

Description Displays the static IP address to the CMC.

Legal Values A Valid IPv4 address

Default A Valid IPv4 address

cfgNicCurrentNetmask (Read Only)

Table 338. Details of cfgNicCurrentNetmask attribute

Description Displays the static subnet mask for the CMC IP address

Legal Values A Valid IPv4 subnet

156 CMC Property Database Group and Object Descriptions

Page 157: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Default A Valid IPv4 subnet

cfgNicCurrentGateway (Read Only)

Table 339. Details of cfgNicCurrentGateway attribute

Description Displays the static gateway for the CMC IP address.

Legal Values A Valid IPv4 gateway

Default A Valid IPv4 gateway

cfgNicCurrentDhcpWasUsed (Read Only)

Table 340. Details of cfgNicCurrentDhcpWasUsed attribute

Description Indicates whether DHCP is used to configure the NIC.

Legal Values 0 — address is static.

0 — address was obtained from the DHCP server.

Default None

cfgNicCurrentVlanEnable (Read Only)

Table 341. Details of cfgNicCurrentVlanEnable attribute

Description Indicates whether the VLAN is enabled.

Legal Values 0 — VLAN is disabled

1 — VLAN is enabled

Default None

cfgNicCurrentVlanID (Read Only)

Table 342. Details of cfgNicCurrentVlanID attribute

Description Indicates the Current Virtual Lan ID

Legal Values Integer

Default None

CMC Property Database Group and Object Descriptions 157

Page 158: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgNicCurrentVlanPriority (Read Only)

Table 343. Details of cfgNicCurrentVlanPriority attribute

Description Indicates the Current Virtual Lan Priority.

Legal Values Integer

Default None

cfgDNSCurrentServer1 (Read Only)

Table 344. Details of cfgDNSCurrentServer1 attribute

Description Displays the IP address for DNS server 1.

Legal Values A Valid IPv4 DNS IP

Default 0.0.0.0

cfgDNSCurrentServer2 (Read Only)

Table 345. Details of cfgDNSCurrentServer2 attribute

Description Displays the IP address for DNS server 2.

Legal Values A Valid IPv4 DNS IP

Default 0.0.0.0

cfgDNSCurrentDomainName (Read Only)

Table 346. Details of cfgDNSCurrentDomainName attribute

Description Displays the DNS domain name.

Legal Values <blank>

Default None

158 CMC Property Database Group and Object Descriptions

Page 159: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgNicCurrentIPv4Enabled (Read or Write)

Table 347. Details of cfgNicCurrentIPv4Enabled attribute

Description Indicates whether IPv4 is enabled on the CMC. If the current property value is set to 0 (false), the remote network interfaces to the CMC are not accessible over IPv4.

Legal Values • 0 — Disabled

• 1 — Enabled

Default 1

Example

racadm getconfig -g cfgCurrentLanNetworking# cfgNicCurrentIPv4Enabled=1# cfgNicCurrentIpAddress=143.166.152.116# cfgNicCurrentNetmask=255.255.255.0# cfgNicCurrentGateway=143.166.152.1# cfgNicCurrentDhcpWasUsed=0# cfgNicCurrentVlanEnable=0# cfgNicCurrentVlanID=1# cfgNicCurrentVlanPriority=0# cfgDNSCurrentServer1=192.168.0.5# cfgDNSCurrentServer2=192.168.0.6# cfgDNSCurrentDomainName=MYDOMAIN

cfgCurrentIPv6LanNetworking (Read Only)This group displays the current CMC IPv6 properties.

Use this object with the getconfig subcommand.

To use this object property, you must have the CMC Login User privilege.

cfgCurrentIPv6Enabled (Read or Write)

Table 348. Details of cfgCurrentIPv6Enabled attribute

Description Indicates whether IPv6 is enabled on the CMC. If the current property value is set to 0 (false), the remote network interfaces to the CMC are not accessible over IPv6.

Legal Values • 0 — Disabled

• 1 — Enabled

Default 0

CMC Property Database Group and Object Descriptions 159

Page 160: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgCurrentIPv6AutoConfigWasUsed (Read or Write)

Table 349. Details of cfgCurrentIPv6AutoConfigWasUsed attribute

Description Indicates whether auto configuration is used to obtain IPv6 settings, including stateless IPv6 addresses and gateway.

Legal Values 0 (static addressing is used)

1 (address is obtained from the DHCPv6 server and/or stateless auto configuration)

Default None

cfgCurrentLinkLocalAddress (Read Only)

Table 350. Details of cfgCurrentLinkLocalAddress attribute

Description Displays the current IPv6 link-local address of the CMC.

Legal Values None

Default None

cfgCurrentIPv6Address (Read Only)

Table 351. Details of cfgCurrentIPv6Address attribute

Description Displays the current IPv6 addresses. This property displays up to 15 global IPv6 addresses, including stateful and stateless addresses.

Legal Values 1

Default 0

cfgCurrentIPv6Gateway (Read Only)

Table 352. Details of cfgCurrentIPv6Gateway attribute

Description Displays the current IPv6 gateway.

Legal Values None

Default None

160 CMC Property Database Group and Object Descriptions

Page 161: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgCurrentIPv6DNSServersFromDHCP6 (Read Only)

Table 353. Details of cfgCurrentIPv6DNSServersFromDHCP6 attribute

Description Indicates whether the DNS server addresses are assigned from the DHCPv6 server.

Legal Values None

Default 0

cfgCurrentIPv6DNSServer1 (Read Only)

Table 354. Details of cfgCurrentIPv6DNSServer1 attribute

Description Displays the IPv6 address for DNS server 1.

Legal Values <blank>

Default None

cfgCurrentIPv6DNSServer2 (Read Only)

Table 355. Details of cfgCurrentIPv6DNSServer2 attribute

Description Displays the IPv6 address for DNS server 2.

Legal Values <blank>

Default None

Example

racadm getconfig -g cfgCurrentIPv6LanNetworking# cfgCurrentIPv6Enabled=1# cfgCurrentIPv6AutoConfigWasUsed=1# cfgCurrentLinkLocalAddress=fe80::21e:4fff:fe1f:5371/64# cfgCurrentIPv6Address1=2009:123::e48f:9dd8:6f51:a669/64# cfgCurrentIPv6Address2=fd88:1::21e:4fff:fe1f:5371/64# cfgCurrentIPv6Address3=fd88:2::21e:4fff:fe1f:5371/64# cfgCurrentIPv6Gateway=fe80::21c:23ff:fe77:6215# cfgCurrentIPv6DNSServersFromDHCP6=1# cfgCurrentIPv6DNSServer1=2009:123::1# cfgCurrentIPv6DNSServer2=::

cfgNetTuningThis group enables users to configure the advanced network interface parameters. When configured, the updated settings may take up to a minute to become active.

CMC Property Database Group and Object Descriptions 161

Page 162: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

CAUTION: Use extra precaution when modifying properties in this group. Inappropriate modification of the properties in this group can result in your RAC NIC become inoperable.

The following sections provide information about the objects in the cfgNetTuning group.

cfgNetTuningNicSpeed (Read or Write)

Table 356. Details of cfgNetTuningNicSpeed attribute

Description Specifies the speed for the CMC NIC. This property is used only if cfgNetTuningNicAutoNeg is set to 0.

Legal Values 10, 100, or 1000

Default 100

cfgNetTuningNicAutoneg (Read or Write)

Table 357. Details of cfgNetTuningNicAutoneg attribute

Description Enables auto negotiation of physical link speed and duplex. If enabled, auto negotiation takes priority over other values set in this group.

Legal Values • 0 = Auto Negotiation is Disabled

• 1 = Auto Negotiation is Enabled

Default 1

Example

racadm getconfig -g cfgNetTuningcfgNetTuningNicSpeed=100cfgNetTuningNicFullDuplex=1cfgNetTuningNicMtu=1500cfgNetTuningNicAutoneg=1

cfgNetTuningNicFullDuplex (Read or Write)

Table 358. Details of cfgNetTuningNicFullDuplex attribute

Description Specifies the duplex setting for the NIC. This property is used only if thecfgNetTuningNicAutoNeg is set to 0 (disabled).

Legal Values • 0 (Half Duplex)

• 1 (Full Duplex)

Default 1

162 CMC Property Database Group and Object Descriptions

Page 163: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgNetTuningNicMtu (Read or Write)

Table 359. Details of cfgNetTuningNicMtu attribute

Description Indicated the maximum size of units in bytes transmitted by NIC.

Legal Values 576–1500

Default 1500

NOTE: IPv6 requires a minimum MTU of 1280. If IPv6 is enabled, and cfgNetTuningMtu is set to a lower value, the CMC uses an MTU of 1280.

cfgRacSecurityThis group is used to configure settings related to CMC SSL certificate signing request (CSR) feature. The properties in this group must be configured before generating a CSR. Use this object with the config or getconfig subcommands. To use this object property, you must have the Chassis Configuration Administrator privilege.

For more information about generating certificate signing requests, see the subcommand sslcsrgen.

For the country code, go to the link http://www.iso.org/iso/country_codes/iso_3166_code_lists.htm

The following sections provide information about the objects in the cfgRacSecurity group.

cfgRacSecCsrCommonName (Read or Write)

Table 360. Details of cfgRacSecCsrCommonName attribute

Description Specifies the CSR Common Name (CN) that must be an IP or CMC name as given in the certificate.

Legal Values A string of up to 64 characters.

Default <blank>

cfgRacSecCsrOrganizationName (Read or Write)

Table 361. Details of cfgRacSecCsrOrganizationName attribute

Description Specifies the CSR Organization Name (O).

Legal Values A string of up to 64 characters.

Default <blank>

CMC Property Database Group and Object Descriptions 163

Page 164: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRacSecCsrOrganizationUnit (Read or Write)

Table 362. Details of cfgRacSecCsrOrganizationUnit attribute

Description Specifies the CSR Organization Unit (OU).

Legal Values A string of up to 64 characters.

Default <blank>

cfgRacSecCsrLocalityName (Read or Write)

Table 363. Details of cfgRacSecCsrLocalityName attribute

Description Specifies the CSR Locality (L).

Legal Values A string of up to 128 characters.

Default <blank>

cfgRacSecCsrStateName (Read or Write)

Table 364. Details of cfgRacSecCsrStateName attribute

Description Specifies the CSR State Name (S).

Legal Values A string of up to 128 characters.

Default <blank>

cfgRacSecCsrCountryCode (Read/Write)

Table 365. Details of cfgRacSecCsrCountryCode attribute

Description Specifies the CSR Country Code (CC).

Legal Values A string of 2 alphabet country code.

Default US

164 CMC Property Database Group and Object Descriptions

Page 165: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgRacSecCsrEmailAddr (Read or Write)

Table 366. Details of cfgRacSecCsrEmailAddr attribute

Description Specifies the CSR email address.

Legal Values A string of up to 64 characters.

Default <blank>

Example

racadm config -g cfgRacSecuritycfgRacSecCsrKeySize=1024cfgRacSecCommonName=cfgRacSecOrganizationName=cfgRacSecOrganizationUnit=cfgRacSecLocalityName=cfgRacSecStateName=cfgRacSecCountryCode=cfgRacSecEmailAddr=

cfgRacSecCsrKeySize (Read or Write)

Table 367. Details of cfgRacSecCsrKeySize attribute

Description Specifies the SSL asymmetric key size for the CSRs.

Legal Values 1024, 2048, and 4096

Default 2048

cfgQuickDeployThis group is used to configure IDRAC deployment settings. You must have blade administrator privileges for configuring the settings.

cfgActionOnServerInsertion

Table 368. Details of cfgActionOnServerInsertion attribute

Description Configures settings when a new server is inserted into the slot.

Legal Values • 0 — No Action

• 1 — QuickDeploy Only

• 2 — Server Profile Only

• 3 — Quick Deploy and Server Profile

Default 0

CMC Property Database Group and Object Descriptions 165

Page 166: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgSetiDRACRootPasswordOnServerInsertion

Table 369. Details of cfgSetiDRACRootPasswordOnServerInsertion attribute

Description Sets the iDRAC root password when a server is inserted into the chassis.

Legal Values • 0 (False) — If the value is ‘1’ when the server is inserted, the iDRAC root password is not set.

• 1 (True) — If the value is ‘1’ when the server is inserted, the iDRAC root password is set.

Default 0

cfgiDRACRootPassword

Table 370. Details of cfgiDRACRootPassword attribute

Description The root password is applied when servers are inserted into the chassis.

Legal Values Up to 64 characters.

Default calvin

cfgEnableiDRACLAN

Table 371. Details of cfgEnableiDRACLAN attribute

Description Enables the LAN channel for iDRAC when servers are inserted into the chassis.

Legal Values • 0 — Disable

• 1 — Enable

Default 1

cfgEnableiDRACIPv4

Table 372. Details of cfgEnableiDRACIPv4 attribute

Description Enables IPv4 for each iDRAC in the chassis. Any iDRAC that is not IPv6 is always IPv4 enabled.

Legal Values • 0 — Disable

• 1 — Enable

166 CMC Property Database Group and Object Descriptions

Page 167: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

Default 1

cfgEnableiDRACIPMIOverLAN

Table 373. Details of cfgEnableiDRACIPMIOverLAN attribute

Description Enables IPMI over LAN channel for iDRAC when servers are inserted into the chassis.

Legal Values • 0 — Disable

• 1 — Enable

Default 0

cfgEnableiDRACIPv4DHCP

Table 374. Details of cfgEnableiDRACIPv4DHCP attribute

Description Enables DHCP for iDRAC when servers are inserted into the chassis.

Legal Values • 0 — Disable

• 1 — Enable

Default 1

cfgStartingiDRACIPv4Address

Table 375. Details of cfgStartingiDRACIPv4Address attribute

Description The static IPv4 address for the iDRAC located in the first slot.

Legal Values IP format

Default 192.168.0.121

cfgiDRACIPv4GateWay

Table 376. Details cfgiDRACIPv4GateWay attribute

Description IPv4–specific default gateway that is common to all the IPv4–enabled iDRACs present in the chassis.

Legal Values IP format

Default 0.0.0.0

CMC Property Database Group and Object Descriptions 167

Page 168: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgiDRACIPv4Netmask

Table 377. Details of cfgiDRACIPv4Netmask attribute

Description IPv4–specific subnet mask that is common to all iDRACs present in the chassis.

Legal Values IP format

Default 255.255.255.0

cfgEnableiDRACIPv6

Table 378. Details cfgEnableiDRACIPv6 attribute

DescriptionEnables IPv6 for each IPv6-capable iDRAC present in the chassis.

Legal Values • 0 — Disable

• 1 — Enable

Default 0

cfgEnableiDRACIPv6AutoConfig

Table 379. Details of cfgEnableiDRACIPv6AutoConfig attribute

Description

Enables the IPv6 feature that allows each iDRAC present in the chassis to set its IPv6 address automatically, without manual configuration of the host or DHCP servers.

Legal Values • 0 — Disable

• 1 — Enable

Default 0

cfgiDRACIPv6PrefixLength

Table 380. Details of cfgiDRACIPv6PrefixLength attribute

Description

The length of the subnet in bits that is common to all IPv6-enabled iDRACs present in the chassis.

Legal Values 0–128

Default 64

168 CMC Property Database Group and Object Descriptions

Page 169: Dell Chassis Management Controller Version 6.10 for ... · 26.11.2014 · Dell Chassis Management Controller Version 6.10 for PowerEdge M1000e RACADM CLI Guide

cfgiDRACIPv6Gateway

Table 381. Details of cfgiDRACIPv6Gateway attribute

Description

IPv6-specific default gateway that is common to all IPv6-enabled iDRACs present in the chassis.

Legal Values IPv6 format

Default ::

cfgReservedIPAddressNumbers

Table 382. Details of cfgReservedIPAddressNumbers attribute

DescriptionThe number of static IPv4 addresses reserved for iDRACs in the chassis.

Legal Values 32

Default 32

cfgUseCMCDNSSettings

Table 383. Details of cfgUseCMCDNSSettings attribute

Description

Propagates the CMC DNS Server settings (IPv4 and IPv6) to iDRAC when a blade server is inserted in the chassis.

Legal Values • 0 — False

• 1 — True

Default 0

CMC Property Database Group and Object Descriptions 169