  • RCOM PM Check List..Title Answer CommentCustomer Name RCOM

    Circle Name : DEL.Cluster Area : Del_Central Zone.Site ID : DL_DELHI_265_10.FAC ID : DCDLHICDFCB003.Site Name : Andrews ganj.ZTM Name : ateeq ur rahman.Title Answer CommentInfra Type RTT

    Date of PM : 28-09-2015 11:42:19 AM.

  • GPS Lat Long :Location Lat / Long : 28.56825856 / 77.22577572

    .Title Answer CommentSite Type: ( Critical >10/ Major , 1/ Minor=1) CRITICAL

    No of sites dependent : 3

  • .BSC Name : Bsc-8.Title Answer CommentIP Owner OWN SITE

    Site accessibility : Access Issue.Cabinet Type (Select no. of cabinet type) : 12.Choose BTS - 1 : 2G, 3G, CDMA.Cabinet Type - 2 : Huawei, Lucent.CDMA - 3 : MOD 4.GSM - 4 : BTS 3012.3G - 5 : BTS3900.Other - 6 : MTS.Choose BTS - 7 : 2G, 3G, CDMA.Cabinet Type - 8 : Huawei, Lucent.CDMA - 9 : NA.GSM - 10 : NA.3G - 11 : NA.Other - 12 : Tata.BTS (Select no. of BTS) : 28.Title Answer CommentBTS - 1 1Choose Cell - 2 CELL A

    VSWR Setting ( As per standard value should be Class 1 = 1.8 ,Class 2 = 1.5 ) - 3

    CLASS 1 =1.8 &CLASS2 = 1.58

    ASM Setting ( Time 1440 , Samples 7000 ) - ON - Screen printshot to be attached ( Antenna 1 ) - 4

    TIME 1440 ,SAMPLES7000

  • ASM Setting ( Time 1440 , Samples 7000 ) - ON - Screen printshot to be attached ( Antenna 2 ) - 5

    TIME 1440 ,SAMPLES7000

    ASM setting for alarm supervision ( Class 2 - 5 dBm & Class 1 - 8dBm ) - 6

    CLASS 2 - 5DBM&CLASS 1 -8 DBM

    VSWR Values ( DX1 ) - 7 : 1.13.VSWR Values ( DX2 ) - 8 : 1.20.VSWR Values ( TX1 ) - 9 : 1.19.Title Answer Comment3G Antenna Threshold value ( 50 / Not OK ) - 10 50

    Colocated 3G BTS - VSWR ( DX1 ) - 11 : 1.13.Colocated 3G BTS - VSWR ( DX2 ) - 12 : 1.16.Colocated 3G BTS - VSWR ( TX1 ) - 13 : 1.19.Title Answer CommentNMS Visibility Status - 14 OKBTS - 15 1Choose Cell - 16 CELL A

    VSWR Setting ( As per standard value should be Class 1 = 1.8 ,Class 2 = 1.5 ) - 17

    CLASS 1 =1.8 &CLASS2 = 1.58

    ASM Setting ( Time 1440 , Samples 7000 ) - ON - Screen printshot to be attached ( Antenna 1 ) - 18

    TIME 1440 ,SAMPLES7000

    ASM Setting ( Time 1440 , Samples 7000 ) - ON - Screen printshot to be attached ( Antenna 2 ) - 19

    TIME 1440 ,SAMPLES7000

    ASM setting for alarm supervision ( Class 2 - 5 dBm & Class 1 - 8dBm ) - 20

    CLASS 2 - 5DBM&CLASS 1 -8 DBM

    VSWR Values ( DX1 ) - 21 : 1.14.VSWR Values ( DX2 ) - 22 : 1.20.VSWR Values ( TX1 ) - 23 : 1.18.

  • Title Answer Comment3G Antenna Threshold value ( 50 / Not OK ) - 24 50

    Colocated 3G BTS - VSWR ( DX1 ) - 25 : 1.20.Colocated 3G BTS - VSWR ( DX2 ) - 26 : 1.21.Colocated 3G BTS - VSWR ( TX1 ) - 27 : 1.12.Title Answer CommentNMS Visibility Status - 28 OK

    Title Answer CommentShelter door condition CLOSEShelter door lock status WORKING

    Link (Select no. of link) : 34.Far End Site ID - 1 : DL6 Delhi 442G.Type of Link - 2 : PDH.Title Answer CommentNMS Visibility - 3 YES

    Alarms on TXMN Eqpt. - 4 : none.Rcv Level [Actual] ( RX1/RX2 ) - 5 : -25 dbm.Rcv Level [Planned] - 6 : -25 dbm.Tx Power planned - 7 : +23dbm.Tx Power Actual - 8 : +23 dbm.Radio index ( Type of Radio ) - 9 : pdh.Link Capacity ( 4E1/8E1/16E1/32E1/63E1/75E1 ) ( 1+1/1+0 ) - 10 : 16E1.Title Answer CommentLink Remarks (1+1/1+0) - 11 1+0

    Link Type ( Ring/Star/Linear ) - 12 : Linear.

  • MW Antenna size ( Planned/Installed ) - 13 : .3 meter.MW Antenna Height ( Planned vs Actual ) - 14 : 35 meter.Tx Frequency ( Planned ) - 15 : 18580mhz.Tx Frequency ( Actual ) - 16 : 18580mhz.Title Answer CommentODU Earthing - 17 OK

    Far End Site ID - 18 : DL6 delhi 274G.Type of Link - 19 : NEC.Title Answer CommentNMS Visibility - 20 YES

    Alarms on TXMN Eqpt. - 21 : no.Rcv Level [Actual] ( RX1/RX2 ) - 22 : -35 dbm.Rcv Level [Planned] - 23 : -35 dbm.Tx Power planned - 24 : 12 dbm.Tx Power Actual - 25 : 12 dbm.Radio index ( Type of Radio ) - 26 : IP radio.Link Capacity ( 4E1/8E1/16E1/32E1/63E1/75E1 ) ( 1+1/1+0 ) - 27 : 16E1.Title Answer CommentLink Remarks (1+1/1+0) - 28 1+0

    Link Type ( Ring/Star/Linear ) - 29 : Linear.MW Antenna size ( Planned/Installed ) - 30 : .6.MW Antenna Height ( Planned vs Actual ) - 31 : .6.Tx Frequency ( Planned ) - 32 : 14739 mhz.Tx Frequency ( Actual ) - 33 : 14739 mhz.

  • Title Answer CommentODU Earthing - 34 OK

    Title Answer CommentWeather proofing kit provided by Customer NOMW / IF Connectors weather proofing at all MW ODUs DONEAll Feeder cable & Jumper connectors weather proofing at GSMantenna interface & feeder-Jumper interface DONE

    Weather proofing of IF cable grounding point & feeder cablegrounding points. [ OK / NOT OK ] OK

    Earthing of all MW ODUs DONECheck Antennae Mountings and Fixtures ( GSM & MW) tightening& installation as per guidelines. OK

    MW Coupler/Strut rods fixing for 1.2,1.8 Mtr MW Antenna as perinstallation guidelines ( 90 degree +- 15 degree ) OK

    RF/ IF cable is free from damages. DONEIf site is monkey impacted then protection of weather proofing byany type of covering & protection of IF cable by conduit pipe. (OK/ NOT OK/ NA)

    NA

    Routing of IF/ Feeder/ OFC cables/Patch cord (Tied with Tie/Clamp) & entry to roxtek. In Snake shape OK

    Is there any rusting of EGB/IGB/strips? NOCORROSION ON ANY NUT/BOLT/WASHER/LUGS USED FOREARTHING YES

    Is EGB/IGB is connected to earthing Pits NOTHE EARTHING CONNECTIONS OF EQUIPMENT SHOULD BETIGHT DONE

    Labeling on Mw antennas/ RAUs for far end ID & feeder cables forcell identification. DONE

    There is no extra antenna/ radio/ material on the tower which isnot in use. AVALIABLE

    Any near & far obstructions Observed at RF antennas (Within 150m diameter) (Yes / No) NO

    LOS BLOCK Observed in Mw Antenna. (Yes / No) NOTHE GPS ANTENNA SHOULD BEVERTICALLY/HORIZONTALLY ISOLATED FROM ANY ACTIVETRANSMIT ANTENNA BY AT LEAST 3.05 M

    OK

    Water leakages in Shelter/Equipment (YES/NO) YESTarpoline provided by RCOM for leaked shelters YESTMA installed on site 2TMA working on site 2Extra TMA lying on site 0Metallic cable tie for outdoor & plastic tie for indoor is used. DONEEMF Danger Signage Boards Present on Tower YESEMF Caution Signage Boards Present on Access Boundry YESEMF Warning Signage Boards Present on Shelter Door YESRoxtek Sealing & any other seepage sealing. ( OK/ NOT OK) DONE

  • Transmission Eqpts connected to critical LVD ( DONE / NOTDONE) DONE

    The cables connections inside equipment are tight. (Yes / No) YESGrouting of MW & BTS rack is proper. OKGrounding of telecom equipments. OKa)-MW rack DONEb) MW Magazines DONEc) BTS Eqpt DONEd) IGB to EGB & Earth pit connectivity NOT DONEe) Fan Units DONEAll cables routing ( Jumpers, Feeder, PCM/E1, alarm, power ), dcpower cable ( OK/ Not OK) OK

    All cables labeling ( Jumpers, Feeder, PCM/E1, alarm, power ),IDUs for far end, dc power cable in SMPS ( OK/ Not OK) OK

    All the PCM/E1 / Patch cord cables in Transmission rack arerouted properly. DONE

    BTS door fitted properly & door filter is clean. DONEBTS & Tx cabinet is cleaned. DONEFAN Filter Cleaning in Transport equipment (Done/ Not done) DONE

    The ESD wrist strap should be available & functional -Available &Functional / Available & not functional / Not Available

    AVAILABLE&FUNCTIONAL

    Dummy plates are present in all empty slots - BTS NODummy plates are present in all empty slots - Tx equipments (AXX/ TN) NO

    All Fan units installed & working for Hi CAP/ MLE above the AMM, TN & BTS. YES

    Is there any extra material kept on site NO1+1 power card availability of Tx equipments ( AXX/ TN etc) YESMW node visibility on NMS [ YES / NO ] YES

    Infra issues observations- ( AC Faulty/ Less than Existing Points in MARS Tool capacity/ HighTemp/ Door Open/ Missing earthlings, Battery cell leakage Any other issue etc) (Select no. ofinfra issue observation) : 5.Title Answer CommentHigh Temp at site - 1 NODoor Open - 2 YESMissing Earthing - 3 YESBattery Cell Leakage - 4 NO

    Any Other Issue - 5 : shalter leakage and fiber cable not properly route.Any BTS and Transmission Alarms at site : no.Title Answer CommentQuality audit done by ZTM (Yes / No) YES

  • Take photo of O/D :

    .

  • Take photo of I/D :

    .

  • Take photo of Issue :

    .Issue details / Remarks : shalter leakage.