ATTUATORE PER CANCELLI SCORREVOLI A CREMAGLIERA ACTUATOR FOR RACK SLIDING GATES ACTIONNEUR POUR PORTAILS COULISSANTS A CREMAILLERE ANTRIEB FÜR ZAHNSTANGEN-SCHIEBETORE SERVOMOTOR PARA CANCELAS CORREDERAS DE CREMALLERA ACTUATOR VOOR SCHUIFHEKKEN MET TANDHEUGEL
Attenzione! Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur!Achtung! Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! Let op! Lees de “Waarschuwingen” aan de binnenkant zorgvuldig!
D81
1972
001
00_1
2 2
1-08
-18
DEI
MO
S B
T A
400
DEI
MO
S B
T A
600
FIG. 3
C
B
Eclick
D
CLOSE
(180°)
(180°)
A
OPEN
MANUALE D’USO: MANOVRA MANUALE/ USER’S MANUAL: MANOVRA MANUALE/ MANUEL D’UTILISATION: MANOVRA MANUALE/ BE-DIENUNGSANLEITUNG: MANOVRA MANUALE/ MANUEL DE USO: MANOVRA MANUALE/ MANUAL PARA DE USO: MANOVRA MANUALE
8 - DEIMOS BT A 400 - DEIMOS BT A 600
D81
1972
001
00_1
2
2x0.75mm2
3x1.5mm2RG58
3x1.5mm 2
3x1.5mm 2
5x0,75mm2
2x1.5mm2
17mm + “X”
“X”=Cremagliera (FIG J), Rack (FIG J), Crémaillère (FIG J), Zahnstange (FIG J), Cremallera (FIG J), Tandheugel (FIG J)
Y + 50 mm
> 10mm
> 25mm 60-70mm
A
D
B
E
1
2
C4
3A 3B
43
Y
F
E1
C1
ITALIA
NO
ENG
LISHFRA
NÇA
ISD
EUTSCH
ESPAÑ
OL
NEDERLANDS
DEIMOS BT A 400 - DEIMOS BT A 600 - 15
D81
1972
001
00_1
2
LET OP! Belangrijke veiligheidsinstructies. De waarschuwingen en de instructies die met het product meegeleverd worden zorgvuldig lezen en volgen, aangezien verkeerde installatie schade aan personen, dieren of voorwerpen kan veroorzaken. De waarschuwingen en de instructies geven belangrijke aanwijzingen over de veiligheid, de installatie, het gebruik en het onderhoud. De instructies bewaren om ze aan de technische folder toe te voegen voor toekomstige raadpleging.
ALGEMENE VEILIGHEIDDit product is uitsluitend ontworpen en gebouwd voor het gebruik aangegeven in deze documentatie. Soorten gebruik anders dan hetgeen aangegeven, zouden schade aan het product en gevaar kunnen veroorzaken.- De constructie-elementen van de machine en de installatie moeten overeenkomstig de volgende Europese Richtlijnen zijn, indien toepasbaar: 2014/30/UE, 2014/35/UE, 2006/42/UE, 2011/305/UE, 2014/53/UE en daaropvolgende wijzigingen. Voor alle landen buiten de UE is het voor een goed veiligheidsniveau nuttig om naast de nationaal geldende normen, ook de genoemde normen in acht te nemen.
- Het Bedrijf wijst iedere willekeurige verantwoordelijkheid af voortkomende uit een verkeerd gebruik of een ander gebruik dan het voorbestemde gebruik en dat aan-gegeven in deze documentatie, evenals uit het niet in acht nemen van het Goed Gebruik bij de constructie van de sluitingen (deuren, hekken, etc..) en uit de vervor-mingen die tijdens het gebruik zouden kunnen optreden.
- De installatie moet worden uitgevoerd door gekwalificeerd personeel (professio-nele installateur, volgens EN12635), met inachtneming van het Goed Gebruik en de geldende normen.
- Alvorens het product te installeren, alle structurele wijzigingen aanbrengen betref-fende de verwezenlijking van de vrijboorden en de beveiliging of afscheiding van alle zones met gevaar voor pletting, snijden, meeslepen en algemeen gevaar, vol-gens hetgeen voorgeschreven wordt door de normen EN 12604 en 12453 of even-tuele plaatselijke installatienormen. Controleren of de bestaande structuur over de noodzakelijke vereisten beschikt wat betreft stevigheid en stabiliteit.
- Alvorens te beginnen met de installatie, de goede toestand van het product controleren.- Het bedrijf is niet verantwoordelijk voor het niet naleven van het Goed Gebruik bij de constructie en het onderhoud van de te motoriseren kozijnen, en van de vervor-mingen die zich tijdens het gebruik kunnen voordoen.
- Controleren of het opgegeven temperatuurinterval compatibel is met de plek be-stemd voor de installatie van het automatiseringssysteem.
- Dit product niet in een explosieve omgeving installeren: de aanwezigheid van gas of ontvlambare rookgassen vormt een ernstig gevaar voor de veiligheid.
- De stroomvoorziening uitschakelen vóór wat voor werkzaamheden dan ook aan de installatie. Ook eventuele bufferbatterijen loskoppelen, indien aanwezig.
- Voordat men de elektrische voeding aansluit, moet men controleren of de gegevens op de plaat overeenstemmen met die van het elektriciteitsnet en of er stroomop-waarts de elektrische installatie een geschikte differentiële drukschakelaar en een geschikte bescherming tegen overstroom staat. Op het voedingsnet van het auto-matiseringssysteem een omnipolaire (magneet)schakelaar voorzien waarmee een volledige uitschakeling mogelijk is in de omstandigheden van overspanningscate-gorie III.
- Controleren of er zich aan het begin van het voedingsnet een aardlekschakelaar bevindt die de drempel van max. 0,03A en de geldende normen niet overschrijdt.
- Controleren of het aardingssysteem correct is uitgevoerd: alle metalen delen van de sluiting (deuren, hekken, etc.) en alle onderdelen van de installatie voorzien van aardingsklemmen aarden.
- De installatie moet worden uitgevoerd met gebruik van veiligheidsinrichtingen en bedieningen overeenkomstig EN 12978 en EN12453.
- De botsingskrachten kunnen verminderd worden door middel van het gebruik van vervormbare randen.
- In het geval dat de botsingskrachten de door de normen voorziene waarden over-schrijden, inrichtingen aanbrengen die gevoelig zijn voor elektriciteit of druk.
- Alle veiligheidsinrichtingen (fotocellen, gevoelige randen, etc.) aanbrengen die noodzakelijk zijn om het gebied te beschermen tegen gevaren voor botsing, plet-ting, meeslepen en snijden. Rekening houden met de geldende normen en richtlij-nen, de criteria van het Goed Gebruik, het gebruik, de installatieomgeving, de wer-king van het systeem en de door het automatiseringssysteem ontwikkelde krachten.
- De door de geldende normen voorziene signalen aanbrengen om de gevaarlijke zo-nes aan te duiden (de restrisico’s). Iedere installatie moet op zichtbare wijze worden geïdentificeerd volgens hetgeen voorgeschreven door de EN13241-1.
- Na de installatie voltooid te hebben, een identificatieplaat van de deur / het hek aanbrengen.
- Dit product mag niet worden geïnstalleerd op vleugels waarin deuren zijn opgeno-men (tenzij de motor uitsluitend kan worden geactiveerd wanneer de deur dicht is).
- Als het automatiseringssysteem is geïnstalleerd op een hoogte van minder dan 2,5 m of als het toegankelijk is, is het noodzakelijk een passende beschermingsgraad van de elektrische en mechanische delen te garanderen.
- Alleen voor automatiseringssystemen voor rolluiken 1) De bewegende delen van de motor moeten op een minimale hoogte van 2,5 m boven de vloer of een ander niveau waar de toegang mogelijk is geïnstalleerd worden.
2) De reductiemotor moet in een afgescheiden ruimte geïnstalleerd worden voorzien van een beveiliging zodat hij alleen met gebruik van gereedschap toegankelijk is.
- Iedere willekeurige vaste bediening zo installeren, dat deze geen gevaar vormt en ver van beweegbare delen is. In het bijzonder de bedieningen bij aanwezige persoon moeten direct zichtbaar zijn vanaf het geleide deel, en, tenzij het gaat om bedieningen met sleutel, moeten deze worden geïnstalleerd op een hoogte van minstens 1,5 m en zodanig dat ze niet toegankelijk zijn voor het publiek.
- Minstens één signaleringsinrichting (knipperend) aanbrengen in een zichtbare posi-tie, en daarnaast een bordje “Let op” aan de structuur bevestigen.
- Op permanente wijze een etiket aanbrengen met betrekking tot de werking van de handmatige deblokkering van het automatiseringssysteem en dit in de buurt van de manoeuvreringsinrichting aanbrengen.
- Zorg ervoor dat tijdens de manoeuvre de mechanische risico’s vermeden en bevei-ligd worden en dan met name de botsing, de pletting, het meeslepen, het snijden tussen geleide deel en omliggende delen.
- Na de installatie te hebben uitgevoerd, zich ervan verzekeren dat de instelling van het automatiseringssysteem van de motor juist is uitgevoerd en dat de beveiligings- en deblokkeringssystemen juist functioneren.
- Uitsluitend originele reserveonderdelen gebruiken voor alle onderhouds- of repara-tiewerkzaamheden. Het Bedrijf wijst iedere willekeurige verantwoordelijkheid af uit veiligheidsredenen en vanwege de goede werking van het automatiseringssysteem, als er onderdelen van andere fabrikanten gebruikt worden.
- Geen enkele wijziging uitvoeren aan de componenten van het automatiseringssys-teem, indien niet uitdrukkelijk door het Bedrijf geautoriseerd.
- De gebruiker van de installatie instructies geven wat betreft de restrisico’s, de toege-paste bedieningssystemen en de uitvoering van de handmatige openingsmanoeuvre in geval van nood: de gebruikershandleiding aan de eindgebruiker overhandigen.
Al hetgeen niet uitdrukkelijk voorzien is in de installatiehandleiding, is niet toegestaan. De goede werking van de controller is alleen gegaran-deerd, als de vermelde gegevens in acht worden genomen. Het bedrijf is niet gehouden zich te verantwoorden voor de schade veroorzaakt door het niet in acht nemen van de aanwijzingen vermeld in deze handleiding.Terwijl de hoofdkenmerken van het product ongewijzigd blijven, behoudt het Bedrijf zich het recht voor om op ieder willekeurig moment die wijzi-gingen aan te brengen die zij geschikt acht om het product technisch, constructief en commercieel gezien te verbeteren, zonder deze publicatie te hoeven bijwerken.
WAARSCHUWINGEN VOOR DE INSTALLATEUR- Verpakkingsmaterialen (plastic, karton, polystyrol, etc.) verwerken volgens hetgeen voorzien is door de geldende normen. Nylon zakjes en polystyrol buiten bereik van kinderen bewaren.
AANSLUITINGENLET OP! Gebruik voor de aansluiting op het netwerk: meeraderige kabel met een doorsnede van min. 5x1,5 mm2 of 4x1,5 mm2 voor driefase voeding of 3x1,5 mm2 voor eenfase voeding (de kabel moet bijvoorbeeld van het type H05RN-F met doorsnede 4x1,5 mm2 zijn).Voor de aansluiting van de hulpapparatuur geleiders gebruiken met een doorsnede van min. 0,5 mm2.- Uitsluitend drukknoppen gebruiken met een werkbelasting van min. 10A-250V.- De geleiders moeten verbonden worden door een extra bevestiging in de buurt van de klemmen (bijvoorbeeld met behulp van bandjes) om de delen onder spanning duidelijk gescheiden te houden van de delen met zeer lage veiligheids-spanning.
- Tijdens de installatie moet de stroomtoevoerkabel van zijn bekleding ontdaan worden, zodat de aansluiting van de aardgeleider op de geschikte klem mogelijk wordt, terwijl de actieve geleiders echter zo kort mogelijk gelaten worden. De aardgeleider moet de laatste zijn die gerekt wordt in geval van losraken van de bevestigingsinrichting van de kabel.
OPGELET! de geleiders met zeer lage veiligheidsspanning moeten fysiek geschei-den worden van de geleiders met lage spanning.De toegang tot de delen onder spanning mag uitsluitend mogelijk zijn voor het gekwalificeerde personeel (professionele installateur)
CONTROLE VAN HET AUTOMATISERINGSSYSTEEM EN ONDERHOUDAlvorens het automatiseringssysteem in werking te stellen, en tijdens de onder-houdswerkzaamheden, nauwgezet het volgende nagaan:- controleren of alle onderdelen stevig zijn bevestigd;- de opstart- en stophandelingen in het geval van de handmatige besturing controle-ren;
- de normale of gepersonaliseerde werking controleren.- Alleen voor schuifhekken: de correcte ineengrijping tandheugel-rondselas met een speling van 2 mm over de hele tandheugel controleren; de looprail altijd schoon houden en vrij van afval.
- Alleen voor schuifhekken en –deuren: controleren of de glijrail recht en horizon-taal is en of de wielen geschikt zijn voor het gewicht van het hek.
- Alleen voor hangende schuifhekken (Cantilever): controleren of het hek niet zakt of trilt tijdens de manoeuvre.
- Alleen voor vleugelpoorten: controleren of de rotatie-as van de vleugels perfect verticaal is.
- Alleen voor slagbomen: alvorens het deurtje te openen, moet de veer ontladen zijn (slagboom verticaal).
- De juiste werking van alle veiligheidsinrichtingen controleren (fotocellen, gevoe-lige randen, etc.) en de correcte afstelling van de antibeklemmings-veiligheidsin-richting door te controleren of de waarde van de botsingskracht gemeten in de punten voorzien door de norm EN12445, lager is dan hetgeen aangegeven in de norm EN 12453.
- De botsingskrachten kunnen verminderd worden door middel van het gebruik van vervormbare randen.
- De functionaliteit van de noodmanoeuvre controleren, indien aanwezig.- De openings- of sluitingshandeling met de aangebrachte bedieningsinrichtin-gen controleren.
- De goede toestand van de elektrische aansluitingen en van de bekabelingen controleren, met name de status van de isolatiekousen en de kabelleiders.
- Tijdens het onderhoud de reiniging van de optieken van de fotocellen uitvoeren.- Voor de periode waarin het automatiseringssysteem buiten bedrijf is, de nood-deblokkering activeren (zie paragraaf “NOODMANOEUVRE”) om het geleide deel los te maken en zo de handmatige opening en sluiting van het hek mogelijk te maken.
- Indien de voedingskabel beschadigd is, moet deze vervangen worden door de fabrikant of door diens technische assistentiedienst of alleszins door een persoon met een soortgelijke kwalificatie, teneinde alle risico’s te voorkomen.
- Als er inrichtingen type “D” geïnstalleerd worden (zoals gedefinieerd door EN12453),die anders dan trusted aangesloten zijn, verplicht halfjaarlijks onderhoud voorschrijven.
- Het onderhoud dat hierboven is beschreven moet minstens eenmaal per jaar of vaker als de plaats of de installatie dit vereist, worden verricht.
LET OP! Vergeet niet dat de motoraandrijving een gemak is bij het gebruik van het hek / de poort en geen oplossing biedt voor problemen door defecten en installatiege-breken of gebrek aan onderhoud.
SLOOP De materialen moeten verwijderd worden met inachtneming van de
geldende normen. Uw niet meer gebruikte apparaat, de lege batterijen of accu’s niet bij het huisvuil weggooien. U bent er verantwoordelijk voor al uw afval van elektrische of elektronische apparatuur weg te brengen naar een inzamelpunt voor de recycling ervan.
ONTMANTELINGIn het geval dat het automatiseringssysteem gedemonteerd wordt om op een an-dere plek opnieuw gemonteerd te worden, is het nodig:- De stroomvoorziening uit te schakelen en de hele elektrische installatie los te kop-pelen.
- De actuator van de bevestigingsbasis te verwijderen.- Alle onderdelen van de installatie te demonteren.- In het geval dat enkele onderdelen niet verwijderd kunnen worden of bescha-digd blijken te zijn, deze vervangen.
DE CONFORMITEITSVERKLARINGEN KUNNEN WORDEN INGEZIEN OP DE WEBSITE http://www.bft-automation.com/CEDE MONTAGE- EN GEBRUIKSAANWIJZINGEN KUNNEN WORDEN INGEZIEN IN HET DEEL DOWNLOAD.
D811766_17
QUICK INSTALLATION
TUBE ARRANGEMENT,
Preparation for motor mounting,
Mounting the motor,
Mounting drive accessories,
Fastening limit switch brackets (RH/LH),
G
Y#
AN
TSH
IELD
++
+
F3 1,25A T
F1
ERR
SET
RADI
O
24V -24V +24 VSafe+
COMSTARTOPEN
NO
NO
PHOT
STOPCOM
FAULT 1
BAR
FAULT 2
NC
NC
NC
LN
220-
230V
~ *M
1+
-
+ REF SWESWC SWO
10L
N11
2021
4142
4350
5152
6061
6270
7172
7374
75
S1 S2 S3FAULT2
FAULT1
PHOT
STOP
OPEN
START
BAR
H
24V
!24V~ 220-230V~*
JP3
24V
21
TX1 21
RX1
45
3
50 51 70 72DIP3=OFF
POWER
SWO
SWC
START+ +
S3 S3 X1X1
START STOP
F1 DEIMOS BT A 400 DEIMOS BT A 600
110-120V 1,6AT 1,6AT
220-230V 0,8AT 1AT
16 - DEIMOS BT A 400 - DEIMOS BT A 600
D81
1972
001
00_1
2
Programming keys,
Antenne
Safety devices
Commands
Accessories power supply
Limit switch connector
Blinker
Motor
Power supply
Connection of 1 couple of untested photocells, for tested photocells see the following pages.
ITALIA
NO
ENG
LISHFRA
NÇA
ISD
EUTSCH
ESPAÑ
OL
NEDERLANDS
J
I
I1
1
2
START OKS1 S1 S1
x1S1 S2 S3
RADIO RADIO RADIO
=
AUTO OPEN AUTO CLOSE
AUTO OPEN AUTO CLOSE
5s
S1 S2 S3
S2S1 S3
SET
S2S1 S3
SET
S2S1 S3
SETOK KO
10 11
M
10 11
M
41 4342
41 4342
DEIMOS BT A 400 - DEIMOS BT A 600 - 17
D81
1972
001
00_1
2
MEMORIZING REMOTE CONTROLS
ADJUSTING AUTOSET, KEY
Steadily lit
Continuous �ashing
Intermittent �ashing
opening direction: right
opening direction: left
CP
X= 37
30
12
CVZ
2860
X= 33
30
8
CVZ-S
6X= 40
NO OK
N1
39
50
255
120
135
164
287
K L
M N
PP1
50>
25
>10
0
17
2mm
O
Q
S
Q1
Q3
Q2
18 - DEIMOS BT A 400 - DEIMOS BT A 600
D81
1972
001
00_1
2
R
BAR 8K2
50 51 52 70 71 72 73 74 75
24V ~
24V ~
24 VSafe
COM
PHOT
BAR
STOP
FAULT 1
FAULT 2
NC NC
NC
PHOT
12
12345
51TX1 RX1
12
12345
5250 TX1 RX1
12
12345
TX1 RX1
12
12345
TX2 RX2
12
12345
TX1 RX1
12
12345
TX1 RX1
12
12345
TX1 RX1
12
12345
TX2 RX2
1 PHOT / 1 PHOT CL
1 PHOT / 1 PHOT CL
2 PHOT / 2 PHOT CL
BAR 8K2
50
5250
5250
5150
5150
5150
5150
70
72
70
7273
70
70
72
73
BAR
Bar 1123456
Bar 112345
Bar 212345
Bar 1123456
6
6
Bar 1123456
Bar 112345
Bar 212345
Bar 1123456
6
6
51
5150
5150
5150
52
52
52
74
70
74
7075
7470
5150
7075
7074 8,2Kohm 5%
SAFETY EDGE SAFETY EDGE
DIP
2 O
FF
DIP
4 O
FFD
IP4
ON
DIP
2 O
N
DIP
3 O
FFD
IP3
ON
* 1 BAR/ 1BAR CL
** 1 BAR TEST/ 1 BAR CL TEST
*** 2 BAR TEST/ 2 BAR CL TEST
**** BAR 8K2/ BAR CL 8K2
ITALIA
NO
ENG
LISHFRA
NÇA
ISD
EUTSCH
ESPAÑ
OL
NEDERLANDS
DEIMOS BT A 400 - DEIMOS BT A 600 - 19
D81
1972
001
00_1
2
INSTALLATION MANUAL
1) GENERAL INFORMATIONThe DEIMOS BT A actuator is highly versatile in terms of installation options due to the extremely low position of the pinion, the actuator’s compact nature and the height and depth adjustment features it offers. The adjustable electronic torque limiter provides anti-crush safety. Manual emergency operation is extremely easy to perform using just a release lever.Stopping at end of travel is controlled by electromechanical microswitches.The HAMAL control panel comes with standard factory settings. Any change must be set by means of the TRIMMER and DIP SWITCH settings.
Its main features are: - Control of 1 low-voltage motor- Obstacle detection- Separate inputs for safety devices- Built-in radio receiver rolling code with transmitter cloning.The board has a terminal strip of the removable kind to make maintenance or replacement easier. It comes with a series of prewired jumpers to make the installer’s job on site easier. The jumpers concern terminals: 70-71, 70-72, 70-74. If the above-mentioned terminals are being used, remove the relevant jumpers.
TESTINGThe HAMAL panel controls (checks) the start relays and safety devices (photocells) before performing each opening and closing cycle. If there is a malfunction, make sure that the connected devices are working properly and check the wiring.
2) TECHNICAL SPECIFICATIONS
MOTOR400 600
Power supply 110-120V 50/60Hz 220-230V 50/60 Hz(*)
110-120V 50/60Hz 220-230V 50/60 Hz(*)
Motor 24V 24V
Power input 50W 70W
Max. current demand 0,5A (230V~) - 1A (110V~)
0,5A (230V~) - 1A (110V~)
Pinion module (standard) 4mm (14 teeth) 4mm (14 teeth)
Leaf speed (standard) 12m/min 12m/min
Max. leaf weight - standard** 4000N (≈400kg) 6000N (≈600kg)
Pinion module (fast) 4mm (18 teeth) 4mm (18 teeth)
Leaf speed (fast) 15.5m/min 15.5m/min
Max. leaf weight - fast** 3000N (≈300kg) 3600N (≈360kg)
Max. torque 20Nm 30Nm
Impact reaction Electronic torque limiter
Electronic torque limiter
Lubrication Lifetime greased Lifetime greased
Manual operation Lever-operated mechanical release
Lever-operated mechanical release
Type of use intensive intensive
Buffer batteries (optional extras)
Two 12V 1.2Ah bat-teries
Two 12V 1.2Ah bat-teries
Environmental conditions from -20°C to +55°C from -20°C to +55°C
Protection rating IP24 IP24
Noise level <70dBA <70dBA
Operator weight 7kg (≈70N) 7kg (≈70N)
Dimensions See Fig. K See Fig. K
CONTROL UNIT
Low voltage/mains insulation > 2MOhm 500V
Operating temperature range -20 / +55°C
Thermal overload protection Software
Dielectric rigidity mains/LV 3750V~ for 1 minute
Accessories power supply 24V~ (demand max. 0,2A)24V~safe
AUX 0 - BLINKER NO 24V~powered contact(max.1A)
Fuses Fig. GBuilt-in Rolling-Code radio-receiver frequency 433.92MHz
Setting of parameters and logics TRIMMER + DIP SWITCH
N° of combinations 4 billionMax. n° of remotes that can be memorized 63
Maximum work time 3 minutesPedestrian opening space 30% of the total travel (not modifiable)
(*) Special supply voltages to order.** There are no minimum or maximum dimension restrictions for the guided part that can be used
Usable transmitter versions:All ROLLING CODE transmitters compatible with .
3) TUBE ARRANGEMENT Fig.AInstall the electrical system referring to the standards in force for electrical systems CEI 64-8, IEC 364, harmonization document HD 384 and other national standards.
4) PREPARATION FOR MOTOR MOUNTING FIG.BMake a hole in the ground to accommodate the concrete pad, with anchors embedded in the base plate for fastening the gearbox assembly, keeping to the distances featured in FIG.B.
5) REMOVING THE COVER Fig.C• Unscrew the relevant two front screws (FIG. C - rif.1)• Push as illustrated (FIG.C - rif.2 - rif.3) to release the cover from the two rear
blocks (FIG.C - rif.3A e FIG.C - rif.3B).• Lift the cover (FIG.C - rif.4).
6) MOUNTING THE MOTOR FIG.D
7) MOUNTING DRIVE ACCESSORIES FIG.E-E1Recommended rack types (FIG.L)
8) RACK CENTRING WITH RESPECT TO PINION FIG.M-N1-ODANGER - Welding must be performed by a competent person issued with the necessary personal protective equipment as prescribed by
the safety rules in force FIG.L.
9) FASTENING LIMIT SWITCH BRACKETS FIG.F
10) STOPS FIG.PDANGER - The gate must be fitted with mechanical stops to halt its travel both when opening and closing, thus preventing the gate from
coming off the top guide. Said stops must be fastened firmly to the ground, a few centimetres beyond the electric stop point.
Note: the safety edge P1 must be installed so that it is not triggered by the mechanical stops.
11) MANUAL RELEASE (See USER GUIDE -FIG.3-).Warning Do not JERK the gate open and closed, instead push it GENTLY to the end of its travel.
12) TERMINAL BOARD WIRING Fig. G-QOnce suitable electric cables have been run through the raceways and the auto-mated device’s various components have been fastened at the predetermined points, the next step is to connect them as directed and illustrated in the dia-grams contained in the relevant instruction manuals. Connect the live, neutral and earth wire (compulsory).The mains cable must be clamped in the relevant cable gland (FIG.Q-ref.Q1) and in the grommet (FIG.Q-ref.Q2), while the earth wire with the yellow/green-coloured sheath must be connected in the relevant terminal (FIG.Q-ref.S) and the extra low voltage wires must be run through the relevant grommet (FIG.Q ref.Q3). WARNINGS - When performing wiring and installation, refer to the standards in force and, whatever the case, apply good practice principles. Wires carrying different voltages must be kept physically separate from each other, or they must be suitably insulated with at least 1mm of additional insulation. Wires must be secured with additional fastening near the terminals, using devi-ces such as cable clamps. All connecting cables must be kept far enough away from dissipaters.
12.1) LOCAL COMMANDS Fig. G Pressing the S3 key commands one START. By pressing the key again while the automated device is moving a STOP is commanded.
13) SAFETY DEVICESNote: only use receiving safety devices with free changeover contact.
13.1) TESTED DEVICES Fig.R
13.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS FIG. H
14) MEMORIZING TRANSMITTERS FIG. I
RADIO- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).In the event of manual programming, the first transmitter assigns the RECEIVER’S KEY CODE: this code is required to subsequently clone the radio transmitters.The Clonix built-in on-board receiver also has a number of important advanced features:• Cloning of master transmitter (rolling code or fixed code).• Cloning to replace transmitters already entered in receiver.
24 - DEIMOS BT A 400 - DEIMOS BT A 600
D81
1972
001
00_1
2
ENG
LISHINSTALLATION MANUAL
Terminal Definition DescriptionPo
wer
sup
ply
L LINESingle-phase power supply 220-230V ~50/60 Hz*
N NEUTRAL
JP31TRANSF PRIM Transformer primary winding connection, 220-230V ~.
JP32
JP13 TRANSF SEC Board power supply: 24V~ Transformer secondary winding
Mot
or 10 MOT +Connection motor 1
11 MOT -
Aux
20 AUX 0 -BLINKER 24V (N.O.) (MAX. 1A) Contact stays closed while leaf is operating.
21
Lim
it
swit
ches 41 +REF SWE Limit switch common
42 SWC Closing limit switch SWC (N.C.)
43 SWO Opening limit switch SWO (N.C.)
Acc
esso
ries
pow
er
supp
ly
50 24V-Accessories power supply output.
51 24V+
52 24 Vsafe+ Tested safety device power supply output (photocell transmitter and safety edge transmitter). Output active only during operating cycle.
Com
man
ds
60 Common START and OPEN inputs common
61
Only active on FW < 3.03
START START command button (N.O.).Operation according to “3/4-STEP” logic
Only active on FW ≥ 3.03
START START command button (N.O.).Operation according to “Residential / apartment building operation” logic
62 OPENOPEN command button (N.O.).Gate opened with this command. If the input stays closed, the leaves stay open until the contact is opened. When the contact is open, the automated device closes following the TCA time, where activated.
Safe
ty d
evic
es
70 Common STOP, PHOT and BAR inputs common
71 STOP The command stops movement. (N.C.) If not used, leave jumper inserted.
72 PHOT (*) PHOTOCELL input (N.C.).Operation according to “PHOTOCELL/PHOTOCELL DURING CLOSING” logic. If not used, leave jumper inserted.
73 FAULT 1 Test input for safety devices connected to PHOT.
74
Only active on FW < 3.03
BAR (*)BAR safety edge input (N.C.).Configurable according to the “BAR/ 8K2” logic.The command reverses movement for 2 sec.If not used, leave jumper inserted.
Only active on FW ≥ 3.03
BAR / BAR CL /
BAR TEST / BAR CL TEST /
BAR 8K2 / BAR CL 8K2
(*)
Safety edge input (N.C.).If not used, leave jumper inserted
BAR/8K2 dip
Safety edge check dip
Safety edge operation dip
OFF OFF OFF NC input, no verification, reversal while opening and closing (BAR)OFF OFF ON NC input, no verification, reversal only when closing, stop when
opening (BAR CL)OFF ON OFF NC input, with verification, reversal while opening and closing
(BAR TEST)OFF ON ON NC input, with verification, reversal only when closing, stop when
opening (BAR CL TEST)ON OFF OFF 8K2 input, reversal when opening and closing (BAR 8K2)ON OFF ON 8K2 input, reversal only when closing, stop when opening (BAR
CL 8K2)ON ON OFF ---ON ON ON ---
75 FAULT 2 Test input for safety devices connected to BAR.
Ant
enna Y ANTENNA Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna can interfere with radio reception. If the transmitter’s range is limited, move the antenna to a more suitable position.# SHIELD
*) If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
TABLE “A” - PARAMETERS
TRIMMER Parameter+
min.+
max.
Description
T1 Automatic closing time [s] 0 120 Waiting time before automatic closing.
NOTE: Set to 0 if not used.
T2 Leaf force [%] 10 90Force exerted by leaf/leaves.This is the percentage of force delivered, beyond the force stored during the autoset cycle (and subsequently updated), before an obstacle alarm is generated.
WARNING: It affects impact force directly: make sure that current safety requirements are met with the set value (*). Install anti-crush safety devices where necessary.
T3 Slow-down distance [%] 1(***) 50 Set opening slow-down speed as a percentage of total travel. This distance is travelled at low speed.
NOTE: When this parameter is edited, a new Autoset cycle must be run to confirm it.
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.(***) If the calculated value is less than 30 cm, it is set to 30 cm.
DEIMOS BT A 400 - DEIMOS BT A 600 - 25
D81
1972
001
00_1
2
INSTALLATION MANUAL
TABLE “B” - LOGICS
DIP Logic Default Cross out setting used Description
1 Transmitter programming ON
ON
Enables wireless memorizing of transmitters:1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memorized in standard mode via the radio menu.2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.This mode does not require access to the control panel.IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
OFFDisables wireless memorizing of transmitters and automatic addition of clones.Transmitters are memorized only using the relevant Radio menu or automatically with replays.IMPORTANT: Disables the automatic addition of new transmitters and clones
2 BAR / 8K2 OFFON Input configured as Bar 8k2. Input for resistive edge 8K2.
The command reverses movement for 2 sec.
OFF Input configured as Bar, safety edge.The command reverses movement for 2 sec.
3 Photocell input check OFF
ON Enable safety check on the PHOT input
OFF Safety check on PHOT input not enabled
4 Edge input check OFFON Enable safety check on the BAR input
OFF Safety check on BAR input not enabled
5 Photocells during closing OFF
ON In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately.
OFFWhen beam is broken, photocells are active during both opening and clo-sing. When beam is broken during closing, movement is reversed only once the photocell is cleared.
Only active on FW < 3.03
6 Fast closing OFFON Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF Logic not enabled
7 Block pulses during opening OFF
ON The start pulse has no effect during opening.
OFF The start pulse has effect during opening.
8 3-step logic OFF
ON Switches to 3-step logic; during closing, start reverses movement. 3 step 4 step
CLOSEDopens
opens
DURING CLOSING stop
OPEN closes closes
DURING OPENING stop + TCA
stop + TCA
AFTER STOP opens opens
OFF Switches to 4-step logic.
Only active on FW ≥ 3.03
6 Safety edge input operation OFF
ON Safety edge with active reversal only when closing, when opening the movement stops
OFF Safety edge with active reversal in both directions
7 Fast closing OFFON Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF Logic not enabled
8Residential / apartment
building operation
OFF
ON Sets the automation type of operation:ON = Apartment building
OFF OFF = Residential
Reaction to the START input (wired or radio):Residential Apartment building
CLOSED Opens OpensWHILE CLOSING Stops OpensOPEN Closes ClosesWHILE OPENING STOPS + TCA No effectAFTER STOP Opens Opens
Reaction to the OPEN input (wired):Residential Apartment building
CLOSED Opens OpensWHILE CLOSING Opens OpensOPEN No effect No effectWHILE OPENING Keeps it open Keeps it openAFTER STOP Opens Opens
Reaction to the PEDESTRIAN input (radio):Residential Apartment building
CLOSED Opens partially Opens partiallyWHILE CLOSING Stops Opens partiallyOPEN Closes ClosesWHILE OPENING STOPS + TCA No effectAFTER STOP Opens partially Opens partially
26 - DEIMOS BT A 400 - DEIMOS BT A 600
D81
1972
001
00_1
2
ENG
LISHINSTALLATION MANUAL
• Transmitter database management.• Receiver community management.To use these advanced features, refer to the universal handheld programmer’s instructions and to the general receiver programming guide.
15) AUTOSET ADJUSTMENT FIG. I1Enables Motor Torque to be set automatically.If the power is suddenly disconnected and then restored the automation performs the operations at autoset speed till the travel limits are identified. WARNING!! The autoset operation must be performed only once you have che-cked that the leaf is moving accurately (opening/closing) and that the mechanical stops are positioned correctly. You must run an autoset cycle whenever the slow-down distance (T3) . WARNING! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor the automated device’s movements and keep people and property out of range of the automated device.WARNING: the torque values set by the autoset function refer to the motor force set during the autoset cycle. If motor force is edited, an autoset opening and closing cycle will need to be performed again.WARNING: check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.Setting sensitivity incorrectly can result in damage to property and injury to people and animals.
16)REVERSING THE OPENING DIRECTION (Fig.S)
KEYS
KEYS Description
S1 Add Start Keyassociates the desired key with the Start command.
S2Add Pedestrian Keyassociates the desired key with the pedestrian command.(Pedestrian opening space, see technical specifications)
S2>5s Confirms the changes made to parameter settings and operating
S1+S2>10s
Erase ListWARNING! Erases all memorized transmitters from the receiver’s memory.
S3Pressed BRIEFLY, it gives the START command.
HELD DOWN (>5 sec.), it activates the AUTOSET function.
LED INDICATORS:
POWER Steadily lit: - Mains power on - Board powered - Fuse F1 intact
START Lit: START input activated
OPEN Lit: OPEN input activated
STOP Unlit: STOP input activated
PHOT Unlit: PHOT photocell input activated
FAULT 1 PHOT input safety device test input diagnosticsBAR Unlit: BAR safety edge input activated
FAULT 2 BAR input safety device test input diagnostics
SWCUnlit: leaf fully closedLit: motor limit switch is disengaged
SWOUnlit: leaf fully openLit: motor limit switch is disengaged
ERRUnlit: no errorLIT: see error diagnostics table
RADIO(GREEN)
Unlit: remote programming not active
Radio LED only flashing: Remote programming active, waiting for hidden key.
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
SET
Lit: Set key pressed / Autoset completed successfullyFlashes three times: Autoset in progressFast flashing 10s: Autoset failedFlashing in sync with Radio LED: Transmitter deletion in progressLit 1s: Start/Stop after key S3 pressedLit 10s: Autoset completed correctly
17) ADJUSTMENT PROCEDURE- Before turning the unit on, check electrical connections.
- Set the following parameters: Automatic Closing Time, motor force, slow-down distance.
- Set the logics.- Run the autoset function.
WARNING! Incorrect settings can result in damage to property and injury to people and animals.
WARNING: Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations)
18) INSTALLATION TEST PROCEDURE1. Run the AUTOSET cycle (*)2. Check the impact forces: if they fall within the limits (**) skip to point 9 of the
procedure, otherwise3. Where necessary, adjust the sensitivity (force) parameter: see parameters table. 4. Check the impact forces again: if they fall within the limits (**) skip to point 9
of the procedure, otherwise5. Apply a shock absorber profile6. Check the impact forces again: if they fall within the limits (**) skip to point 9
of the procedure, otherwise7. Apply pressure-sensitive or electro-sensitive protective devices (such as a
safety edge) (**)8. Check the impact forces again: if they fall within the limits (**) skip to point 9
of the procedure, otherwise9. Make sure all devices designed to detect obstacles within the system’s operating
range are working properly(*) Before running the autoset function, make sure you have performed all the
assembly and make-safe operations correctly, as set out in the installation warnings in the drive’s manual.
(**) Based on the risk analysis, you may find it necessary to apply sensitive protective devices anyway
WARNING! Incorrect settings can result in damage to property and injury to people and animals.
LED ERR:
Led ERR
Led SET Lit slow flashing fast flashing
Unlit:
Reverse due to obstacle - Ampe-rostop - Check for obsta-cles in path
Photocell test, Costa o Costa 8k2 failed - Check photocell connection and/or logic settings
Thermal cutout
- Allow automated device to cool
Lit
Internal system supervision control error. - Try switching the board off and back on again.If the problem persists, contact the technicalassistance de-partment.
Limit switch error
- Check limit switch connec-tions
slow flashing
Test hardware card error
- Check the connection to the motor- Hardware pro-blems to the card (contact technical assistance)
Parameters and/or Operating Logic edited- If the “Slow-down distance” is edited, run a new Autoset cycle to confirm the new setting.- If other parame-ters and/or opera-ting logic are edi-ted, hold down S2 for 5s to confirm.NOTE: In any case, the Autoset fun-ction confirms all changes made to the board.
DEIMOS BT A 400 - DEIMOS BT A 600 - 27
D81
1972
001
00_1