19
Dehumidifier Instruction Manual Model DH-320/A

Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Dehumidifier Instruction Manual

Model DH-320/A

Page 2: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

CONTENTS

Safety Warnings 2

Operation consideration 5

Construction & controls 6

Function selection 8

Preparation for use 10

Operation 12

Maintenance 14

Continuous drainage 16

Specifications 17

Trouble-shooting 17

Please read this instruction manual carefully before operating the

dehumidifier.

This manual contains important instructions for its correct operation.

Please retain for future reference.

-1-

Page 3: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Safety Warnings

Please read this section carefully before operating your dehumidifier. The warning and the cautions stated in this section must be observed for safe operation

Warning: means improper operation may result in a serious injury or death to a person.

Caution: means improper operation may result in an injury or damage to property. Shows prohibited operation Shows Compulsory condition Shows Caution condition

Warnings ● In case of any abnormality turn off the dehumidifier, disconnect the power

and contact RS technical support Power off and remove plug

● Never attempt to turn off the dehumidifier by disconnecting the plug. Prohibited

● Never modify the dehumidifier. Do not attempt to disassemble or Prohibited service the unit.

● To avoid the risk of the electric shock, never connect of disconnect Prohibited the plug with wet hands.

● Make sure plug is clean and free from damage. Make sure it fits Clean or replace plug

socket securely ● Do not operate near flammable materials or gasses. Prohibited

Do not spray chemicals on to unit

● To prevent damage, do not place the dehumidifier near heat sources Prohibited

● The power cord must not be damaged or modified. Do not allow objects to Prohibited

rest on the cord. Do not pull on the cord or bundle during operation.

● Avoid damage to the power cord; take care not to trap or pinch cord. Prohibited

-2-

Page 4: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

● Do not insert foreign objects into the dehumidifier Prohibited ● Remove collected water from the tank. Do leave water in the unit if is not Dispose of water

used for extended periods of time. Dispose of water appropriately, do not drink water.

● The dehumidifier must be used on a level and stable surface. Use in flat ground ● To prevent collected water from freezing do not use the dehumidifier Prohibited

at ambient temperatures below 0 ℃

● For indoor use only. Prohibited ● Avoid Exposure to direct sunlight Prohibited

.

● Do not spill water on to the dehumidifier. Switch off & disconnect Prohibited from supply. Mop up excess water & allow to dry ● Do not use unit for specialized environmental applications. Caution

If in doubt please contact RS Technical Support ● Do not use solvents or chemical cleaners. Prohibited ● For continuous drainage make sure that the drain hose is set properly Check hose

without a rising slope. ● Be aware of where units exhaust is directed Prohibited ●Do not place anything on top of unit. Prohibited

-3-

Page 5: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

● Disconnect and remove plug if unit is not to be use for extended periods

When removing plug be sure to hold by molded plug only

● Care must be taken when using in confined spaces Prohibited .

● Do not remove or disable the float in the water tank.. Prohibited ● Do not obstruct air vents. Do not place object immediately in front of the Prohibited dehumidifier ● Periodic checking of air filters and water collection or drainage is Schedule regular checkups advised as failure may reduce efficiency or cause the unit to shutdown ● Before cleaning or routine maintenance switch off and disconnect power ● Make sure the unit is empty of water before moving. Use handle provided Empty water

to transport water container

-4-

Page 6: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Operation considerations

Defrost operation The evaporator within the dehumidifier can frost over during normal operation (at temperatures of approx.15℃ or less). The unit automatically removes the frost at intervals of approximately 30 minutes or more (for a duration of approximately 5 minutes).While this unit performs this cycle both the dehumidifying function and the air cleaning function are suspended ● Do not turn off or disconnect the unit during the defrosting operation.

This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in daily life and for enhanced indoor drying. It is not suitable for sustaining very low humidity levels

Room temperature rises during dehumidifier operation. This dehumidifier does not have a cooling function. It produces heat during normal operation which will have an effect on the surrounding environment. Further more any temperature changes will be respective to the size of the room it is located in. Therefore appropriate considerations should be taken when deciding how and where to locate this unit.

-5-

Page 7: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Construction & Controls

Front Back

Advised installation distances

-6-

Installation For efficient and safe operation of the dehumidifier. The unit should be ideally located taking in to account the spacing’s shown. Note: Since the unit generates heat, special care should be taken around the exhaust

Note In case of interference, keep electrical equipment at least 70cm away form the dehumidifier

Accessory Air Cleaning Filter… 1 piece

Page 8: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Controls

Control panel Indicators Light off ○

Light on ● Light flashing *

Lamp lights up and

the operation stops

automatically when the

water tank is filled with

water (approx..4.0L)

The timer lamps show

the remaining time

of operation

Press ”Timer Select”

switch to set the duration

for automatic stopping.

The indication of current

Environment humidity.

Press ”ON/OFF” switch to start operation, to Stop press the switch again.

Press ”Mode” switch to select the modes of operation (see later)

-7-

Page 9: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Function Selection ____________________________________________________ To dehumidify a room to a comfortable level MODE ____________________________________________________ To dehumidify a closet or storage area ____________________________________________________ To aid the drying process and reduce moisture levels ____________________________________________________ To aid in the drying of water based spills ____________________________________________________ To dehumidify a small space and inhibit the formation of mould ____________________________________________________ To reduce odors and provide a pleasant environment ____________________________________________________ The built-in memory stores the last operation of dehumidifier once the mode has been selected. The unit returns to that operation when the ”Power” button is pressed and the unit is switched on again. (In case of power failure or disconnection, the unit returns to its default settings.)

-8-

Page 10: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Operation mode ”Automatic” ● Open either flap and orientate for optimum operation ● The dehumidifying operation stops automatically when

humidity drops below approx. 60%. The dehumidifier continues the air cleaning operation only (“Automatic operation lamp remains illuminated.)

Operation mode ”Continuous” ● Open either flap and orientate for optimum operation ● The initial timer setting is”2H”, settings can be changed

to ”4H”or”8H” by pressing the “Timer” button successively ● Be sure to locate the dehumidifier in such a manner that the

tank side is easily accessible. If used in a confined space try to reduce the amount of air flow allowed in from outside the target area

“Continuous” operation with additional air flow ● Open either the upward flap or the downward flap for drying

Uniformly specific areas. “Continuous” operation with the downward flap open.

● Open the downward flap for air outlet only. “Continuous” operation with the spot flap open.

● Open the spot flap of air outlet only. “Air Clean”

Note: This unit is not intended for use as an exclusive air cleaner. ● Open either flap and orientate for optimum operation ● Air cleaning function does not work without suitable filter.

-9-

Page 11: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Preparation for use

Installation of dehumidifier air filter. 1. Remove the back cover. Use the indents to lift away cover 2. Remove the filter holder from the back cover. Filter holder is clipped to the inside of the cover. The filter holder then unclips and is ready for the filter 3. Installing/changing filter. Remove the filter out of its packaging and put in the filter holder. Repeat in reverse step 2, placing the filter holder on the clips of the back cover with the flat surface facing up, and set the holder to the four catches in the cover (with the convex portions of the holder upward). Replace the cover securely, pressing its perimeter making sure It is flush ● In case of incorrect alignment of the filter, the cover cannot be correctly replaced. ____________________________________________________________________________

Replacing the cover.

To ease installation, install

one side of the cover first, and then the other.

____________________________________________________________________________

Water tank orientation. NB. The dehumidifier will not operate if the water tank Is full of water or it is not located correctly. How to remove Draw the water tank gently toward you by holding the Concave sides of the tank. How to install Push the tank horizontally and gently. The handle folds down flat within the take. Take care, not to damage to level float in either operation

-10-

Page 12: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Emptying water from a water tank 1. Remove water tank from the dehumidifier and fold up handle 2. Tilt the tank to the direction as shown. and slowly empty the water out of the tank. 3. Set the tank in the dehumidifier taking care not to damage the level float.

Note

As part of the dehumidifiers’ operation, water is collected in the water tank.. Once the tank is full, the dehumidifier stops automatically and the buzzer sounds. The buzzer will sound for 10 seconds while the tank is removed for emptying. For continuous draining, see the page 16.

-11-

Page 13: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Operation Please note: ● The dehumidifier will stop automatically after the duration set by the timer(2H,4H OR 8H) ● If the unit is set to “Continuous” mode, the initial timer setting is “2H”.You can change the

Setting to”4H” or”8H”. __________________________________________________________________________

Plug in dehumidifier to power outlet ● ”Automatic” mode lamp will flash. ● Make sure that the water tank is set property. Orientate air outlet flaps for desired operation. ___________________________________________________________________________

Press “power” switch. ● ”Automatic” mode lamp will light up.

____________________________________________________________________________

Select desired operation by pressing “Mode” switch. ● Each time the mode switch is press, the mode indicator lights up in turn as shown

and that operation mode will be changed. If the wrong mode is selected the modes can be cycled around as shown

●With timer selected, the time duration indicator shows the remaining time.

The unit will shut down after the preset time selected

-

-12-

Page 14: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

_____________________________________________________________________________

Warming

To avoid damage to the power cord, do not pinch the cord in a door. ______________________________________________________________________________ ______________________________________________________________________________

Caution Be sure when using in confined spaces that there is sufficient ventilation ______________________________________________________________________________

Stopping operation Press “power” switch again. ● The mode select indicator will go out and unit will shut down. ● Once the unit has stopped, close any flaps and remove and dispose of any collected water.

Buzzer Whenever a function is selected the buzzer will sound indicating a change in operation.

Note: Be sure to allow free airflow movement though the unit. If the unit does not have sufficient air movement around it, overheat protection devices will stop the dehumidifier from working properly. Due to the nature of this device the dehumidifying operation commence approximately 3 minutes after the unit is first connected or restarted after a power failure.

Immediately after a power failure, the “Automatic” mode lamp will flash. Press the “Power” switch to restart the units’ operation The Efficiency of the dehumidifier is dependant on air flow around the unit. For optimum efficiently, try to avoid excessive opening and closing of windows and doors. For the best performance, operate the dehumidifier under the normal operating temperatures. For safety purposes the dehumidifying operation will stop automatically and change to air cleaning when the ambient temperature exceeds approx. 36℃. Initial circulation of refrigerant may cause sounds from within the dehumidifier when the unit is first started. However after the circulation is stable, the sound will diminish.

To change the timer setting press “timer select” Switch until desired time is reached .

To stop the timer operation To cancel the timer operation Press “Power” Switch

iPress “timer Select ”Switch The timer lamp will go off.

Notes

●Except for “Continuous” mode operation, the timer setting will be cancelled whenever the “Mode” switch is pressed. Set the timer again after pressing “Mode” switch, if necessary. ●The timer stops when the water tank is full of water. After the tank is emptied, the timer will start.

-13-

Page 15: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Maintenance

Warning To avoid of the risk of electric shock. never connect or disconnect plug with wet hands

Cautions Turn off the unit and disconnect the power plug before cleaning or other routine maintenance. Do not remove the float lever from the water tank.

If unit is not used for extended periods of time. 1.Unplug unit, bundle the power cord, and hang at the back of the unit on the hooks provided 2.Empty the water tank, wipe dry with cloth and replace in position. 3.Clean air clean filter. 4.For storing, stand the unit upright and avoid the exposure to the direct sunlight.

Important ● To avoid malfunction or abnormal sound, keep unit upright.

Body of dehumidifier ● To clean wipe dehumidifier with a dry soft cloth. ● To remove heavy dirt, use a damp cloth

(Never use a wet cloth for cleaning the controls) ●To avoid deformation or cracking, do not use thinners or solvent cleaners. ●Chemical cleaners may cause colour changes to unit. _______________________________________________________________________________

Water Tank ● Pull out the water tank using indents and take it out. ● Remove the tank cover and wash the inside of the

tank with water and mild detergent. ● Avoid scratching, do not use abrasives. ● Do not remove the float lever from the tank. ● Wipe off water from the outside of tank with a cloth.

Replace the cover of the tank and replace.. ● Pass the handle through the hole of the tank cover

as shown. Tank cover Hole Tank Handle Float lever

-14-

Page 16: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Back & Side Air Intakes (Maintenance every 2 weeks) ● Dehumidifying efficiency will be reduced if the

air filter becomes clogged. filter holder ● Remove front cover from unit and remove filter

filter holder. Remove air filter from cover ● Pull the side of holder towards you and release

it from the unit. Repeat for the other side ● To dislodge dust from filter, use a vacuum

cleaner or shake lightly. ● If the filter is heavily fouled. Wash in warm

water using a neutral detergent. Rinse well and leave unit dry.

Front cover ● Replace filter and return to unit. filter holder

Air Clean filter (Maintenance every 6 months) ● The life span of an air filter is approx.6 months. ● Replace filter are model No.: DH-320/A

Model No. of Anti bacteria Air clean FILTER: dh-320-14

-15-

Page 17: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Continuous Drainage

Cautions

●For continuous drainage, ensure that drain hose is correctly set Ensure drain hose without a rising slope.

●To prevent the water from freezing, do not use the dehumidifier and drain hose at ambient temperature below 0℃ Prohibit

If there is a suitable drain nearby, you can opt for the continuous draining option. This function enables the dehumidifier operation for hours as it is not necessary to empty the water tank. Before converting, be sure to turn off the dehumidifier and disconnect the power plug. Requirements for continuous draining: Hose for draining (vinyl hose) Length: Distance to drain+approx.30cm Inner diameter: 15mm Outer diameter: 20mm or less

Make the hose opening ● To make the opening, remove the cover for the drain

hose by means of a flat screw screwdriver. This will need to be repeated on internal cover as well

Fit a drain hose. ● Remove water tank and fit adaptor to internal drain.

Ensure retaining screw is fitted. Put the drain hose through the opening and fit to the adaptor securely

Return the water tank as before ● The unit will not be operated without the tank. Even if not in use.

-16-

Page 18: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Specifications Model No. DH-320/A Power Supply 220V~240V (50HZ) De-humidity Capacity 19 (30℃/80%)

Power Consumption 340W

Capacity of water tank 5.0L (auto shut off) Net weight 12kg Dimensions Height 572mm, Length 390mm, Width 286mm Room Temperature 5℃-35℃

The specification may be subject to change without notice

Trouble shooting

Prior to contacting RS, please check for the following:

Malfunction Points to be checked Measures to be taken Ref. page

Check to see if the power is disconnected. Insert the plug into electric outlet

fully and securely 2

Check to see if the water tank is full of

water Empty the water tank.

2 Check to see if the water tank is not set

properly in position.

Set tank in to correct position 10

No operation

Check to see if all the air flaps are closed. Open one of the flaps 12

Check air filters for blockages. Clean the filters as specified or

replace. 12 Check to see if the air vents are

blocked up

Remove obstacles from the air

vents. 12

Dehumidified volume is low

Check to see if the dehumidifier is in air

clean mode

Change the operation mode to the

dehumidifying mode 12 Loud noise while operating

Check to see if the unit is not installed as

Specified.

Install the unit on a level and

stable floor 12 Operation stops during dehumidifying

Check to see if the room temperature is

higher than the usable operating

temperature.

The dehumidifying operation will

start automatically when the

temperature lowers

12

Check to see if drying area is not exposed

he exhaust from the unit. to t

Try to exposed the drying area

to the air flow 12 Drying function not working efficiently Check to see if the room temperature is

too low

Drying becomes less efficient at

lower temperatures. 12

-17-

Page 19: Dehumidifier · This dehumidifier is not suitable for sustained lowering of humidity (approx.50% or less) This dehumidifier is designed to remove uncomfortable levels humidity in

Note the following phenomena are normal under standard operating conditions

Phenomenon Reason Operation stops

occasionally

The unit is defrosting (See the page5 )

Dehumidified

volume is small

Dehumidified efficiency is less when the room temperature is low (see the page 6). The unit

stops dehumidifying because the humidity in a room drops to 60% or less while in

“Automatic” mode. (See page 5).

Humidity remains

high

The room size may be too large .(see the page5)

Doors or windows may be opened and/or closed frequently.(see the page5)

The dehumidifier is used to close to moisture emitting devices (some types of heaters).

Bad smell during

operation

While the humidity levels are high mould can form. When the unit is operating it will raise

area temperatures and increase air flow.

Sound is produced

from unit

Circulation of the refrigerant may cause sound until levels have stablised.

The buzzer sounds The buzzer sound when the water tank is full of water.

Please record the following items. Model DH-320/A Purchase Date Supplier RS Components UK

PO Box 99, Corby, Address Northants., NN17 9RS TEL: Tel: 01536 201234 Fax: 01536 405678 http://rswww.comWeb address

-18-