5 DEFENDER Datacom Cabinets Defender™ Datacom Cabinets | 507-287-3535 | www.emcorenclosures.com | CRN.2185.09.16 8,000 BTU Half Rack DEFENDER™ server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, and industrial environments that don’t have cooling infrastructure already in place. Capable of providing up to 4 kW of cooling, these cabinets with NEMA rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system. Cabinet Features Welded 12-gauge steel frame with 2000 static load capacity 28U rack space with square hole rails 36” depth standard 30” and 42” depths available Fully gasketed locking front and rear doors Gland plate in top for cable entry/exit Remote monitoring capability Compatible with 8,000 BTU AC units Cooling capacity approximately 2.6 kW AC Features Designed to mount on the side of the enclosure while maintaining NEMA 12, 3R, 4, or 4X integrity. 120V / 8,000 BTU Digital temperature controller with alarm Built-in condensate evaporator Efficient, quiet, long lasting rotary compressor Environment friendly HFC refrigerant Easy pull-out filter UL Listed Part Number: DC-28U2436-AC8000-D Cabinet | 28U Rack Space | 24” Wide | 36” Deep AC Unit | 8,000 BTU Please consider the following: what are the cooling needs of the equipment that will be housed in the cabinet, what is the height and width of the smallest door or elevator on the path to installation, what is the size of the room where the cabinet will reside, and is there a dedicated receptacle -in the room- capable of handling the power needs of an AC unit. For retrofit jobs; the condition of the existing equipment, the type of rack it is currently housed in, and most importatnly the length of service loop, if any, of the existing cable. + Complete Defender Line Half Rack 3,000 BTU ~1.0 kW cooling Half Rack 6,000 BTU ~2.0 kW cooling Half Rack 8,000 BTU ~2.6 kW cooling Full Rack 12,000 BTU ~4.0 kw cooling Full Rack 8,000 BTU ~2.6 kW cooling

DEFENDER Datacom Cabinets - Crenlo · 5 DEFENDER ™ Datacom Cabinets Defender™ Datacom Cabinets | 507-287-3535 | | CRN.2185.09.16 8,000 BTU Half Rack DEFENDER™ server cabinets

  • Upload
    lamdung

  • View
    259

  • Download
    0

Embed Size (px)

Citation preview

5

D E F E N D E R ™ Datacom Cabinets

Defender™ Datacom Cabinets | 507-287-3535 | www.emcorenclosures.com | CRN.2185.09.16

8,000 BTU Half RackDEFENDER™ server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, and industrial environments that don’t have cooling infrastructure already in place. Capable of providing up to 4 kW of cooling, these cabinets with NEMA rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system.

Cabinet Features• Welded 12-gauge steel frame with 2000 static load capacity• 28U rack space with square hole rails• 36” depth standard 30” and 42” depths available• Fully gasketed locking front and rear doors• Gland plate in top for cable entry/exit • Remote monitoring capability• Compatible with 8,000 BTU AC units • Cooling capacity approximately 2.6 kW

AC Features• Designed to mount on the side of the enclosure while maintaining

NEMA 12, 3R, 4, or 4X integrity.• 120V / 8,000 BTU• Digital temperature controller with alarm• Built-in condensate evaporator• Efficient,quiet,longlastingrotarycompressor• Environment friendly HFC refrigerant• Easypull-outfilter• UL Listed

Part Number: DC-28U2436-AC8000-D

Cabinet | 28U Rack Space | 24” Wide | 36” Deep AC Unit | 8,000 BTU

Please consider the following: what are the cooling needs of the equipment that will be housed in the cabinet, what is the height and width of the smallest door or elevator on the path to installation, what is the size of the room where the cabinet will reside, and is there a dedicated receptacle -in the room- capable of handling the power needs of an AC unit. Forretrofitjobs;theconditionoftheexistingequipment,thetypeofrackitiscurrentlyhoused in, and most importatnly the length of service loop, if any, of the existing cable.

+

Complete Defender Line

Half Rack3,000 BTU

~1.0 kW cooling

Half Rack6,000 BTU

~2.0 kW cooling

Half Rack8,000 BTU

~2.6 kW cooling

Full Rack12,000 BTU

~4.0 kw cooling

Full Rack8,000 BTU

~2.6 kW cooling

6

D E F E N D E R ™ Datacom Cabinets

Defender™ Datacom Cabinets | 507-287-3535 | www.emcorenclosures.com | CRN.2185.09.16

28U

404[15.93]

1069[42.09]

600[24.00]

988[38.88]

1422[56.00]

872[34.34]

76[3.00]

A A

Mounting Dimension

450[17.72]

465[18.30]

95 x 95 [3.75 x 3.75]

390 x 495 max[15.25 x 19.50]

Top (w/ gland plate open)

Back Left SideRight SideFrontFront (w/o door)

Top BottomSection A-A

Technical Specifications

For enclosure or panel cooling, Our exclusive use of a rotarycompressor allows us to manufacture the smallest, lightestweight, most energy efficient cooling solutions in the industry.

Technical Data

Vertical Mount Slim8,000V16 BTUH - 120/230/480 VAC Air Conditioners

Standard FeaturesOptionsTechnical DataAir Flow

Ice Qube, Inc., 141 Wilson Ave., Greensburg, PA 15601 Call: 724.837.7600 Fax: 724.837.3386www.iceqube.com Email: [email protected]

Cooling Solutions

Standard Features

• Digital temperature controller with alarm.• Built-in condensate evaporator.• Durable 16 gauge welded steel construction.• Efficient, quiet, long lasting rotary compressor.• Environment friendly HFC refrigerant.• Easy pull-out filter.• UL Listed.• Space saving aesthetic cabinet design.• Designed to mount on side of enclosure while maintaining NEMA type 12, 3R, 4, or 4X integrity.

Options & Accessories

• Stainless Steel • External Heat Output • Low Ambient• Remote Controller Kit • Internal Heat• Replacement Filters • Alarm Output• Corrosive Packages • Crankcase Heater

8000

BTU

H

* Designed for high ambient applications ** Also available in 400V as non UL

Model BTU/Watts Volts Max Amps Max Temp ºF/ºC Weight (lbs/Kg) Dimensions (In/mm)

IQ8000V16 8000/2345 120/60 13.7 131/55c 105 / 47.6 H 42.09” (1069mm) x W 15.93” (405mm) x D 10.34” (263mm)

IQ8000V16 8000/2345 230/60/50 6.8/7.5 131/55c - (50Hz 140/60c) 105 / 47.6 H 42.09” (1069mm) x W 15.93” (405mm) x D 10.34” (263mm)

IQ8000V16** 8000/2345 480/60/50 3.4/3.7 131/55c 130 / 59.0 H 46.15” (1172mm) x W 15.93” (405mm) x D 10.34”(263mm)

Conditioned Enclosure Air Flow

AmbientAir Flow

2-24-15 Rev 1

Volts* BTU / Watts Max Amps Max Temp Weight HxWxD mm [“]

120 8,000 / 2345 13.7 131°F / 55°C 105 lbs. / 47.6 kg, 1069 x 404 x 263[42.09 x 15.93 x 10.34]

*AC unit available in 230V if required. Ask sales representative for details.

AC Unit