• Heat Recovery ventilation.• Operating at:

- Constant speed (Cube 550 and Cube 550+),- Optional constant airflow or pressure on the Cube

550+.• Airflow from 120 m3/h to 585 m3/h.• Filters (as per class EN 779):

- F7 filter on new air (optional F9 filter),- G4 filter on exhaust air.

• By-pass 100% as standard.• High-efficiency heat exchanger > 90%.• 3 speeds + Stop (version 550).• Air duct connections: Ø 150 mm (adapters Ø 160 mm included) • Sound pressure: at 4 meters, 47 dB(A) at 585 m3/h.• Controlled via:

- Cube 550 wired control,- Cube 550+ touch-screen wired unit (see dedicated

page).• New air or exhaust air: -5°C/+40°C.• Frost protection by balancing airflows.• Pre-heated air (in option).• 2-year warranty.

General and uninterrupted ventilation of dwellings.Heat recovery system.

RANGE

Dee Fly Cube 550

DESCRIPTION

FIELD OF APPLICATION

AdvantagesConpliance• compliance.• ErP ready.

Remote control Dee Fly Cube 550

Remote control Dee Fly Cube 550+

Heat Recovery ventilation

• Reversible connections.• Ventilation control via Interior Air

quality sensors (CO2).• Colour touch screen remote control.• High-efficiency heat exchanger > 90 %.• Energy-efficient motor.

Vertical attachment to wall.Condensate discharge for connection to Ø 32 PVC network (water trap supplied with kit).Humidity-controlled and Self-balanced air supply and exhaust terminal kits.

INSTALLATION

Description Dee Fly Cube 550 Dee Fly Cube 550+Dee Fly Cube 550 - constant speed control X X

Wall attachment bracket X X4 spigots X XWater trap X XRemote control Dee Fly Cube 550 X -Remote control touch-screen Dee Fly Cube 550+

- X

By-pass X X

CONNECTED accessoriesConstant airflow adapter kit - XConstant pressure adapter kit - XPre-heating coil - XCO2 Sensor - XF9 filter on new air - X

RANGE

ErP

* In accordance with eco design 1253/2014 and energy labelling 1254/2014 regulations.** Class obtained according to Labeling 1254/2014 in Local Demand Control.

Description Code Energyefficiency

Dee Fly Cube 550 11023274 BDee Fly Cube 550+ 11023275 A

**

*

Page 3: Dee Fly Cube 550 - Aldes International

3

Dee Fly Cube 550

Water trap• Standard connection to the Dee Fly Cube 550 and to

the drains network for condensate removal.• Dimensions: See page of dimensions.

Replacement filters• For annual servicing. • Dimensions: - G4: 177 x 440 x 25 mm, - F7: 177 x 440 x 25 mm.

Pre-heating coil• Dimensions: 160 x 162 x 250 mm.• Heat exchanger frost protection Ø 32 mm.• Used to heat incoming air.

Constant pressure kit• Dimensions: 150 x 235 x 110 mm.• Additional instructions supplied with product.

Constant airflow kit• Dimensions: 150 x 235 x 110 mm.• Additional instructions supplied with product.

CO2 Sensor• Dimensions: 85 x 100 x 26 mm.• Used to measure CO2 level.

F9 filter• Dimensions: 177 x 440 x 25 mm.• Fine particle filter.

DESCRIPTION ACCESSORIES ACCESSORIES

Water trap

G4 filter

Constant pressure kit / constant airflow

RANGE ACCESSORIES

ADDITIONNAL OFFER TO DEE FLY CUBE 550+

Description CodeFilters (1xG4 + 1xF7) 11023282

Heat Recovery ventilation

Filters F7 / F9

Pre-heating coil CO2 Sensor

RANGE ACCESSORIES DEE FLY CUBE 550+

Description CodeConstant pressure kit 11023279 Constant airflow kit 11023278 Filter F9 11023283 CO2 Sensor 11017090Pre-heating coil 11023280

Page 4: Dee Fly Cube 550 - Aldes International

4

Dee Fly Cube 550 • Weight: 45 kg.

F7, G4, F9 Filter

Pre-heating coil

Technical details Dee Fly Cube 550DIMENSIONS (mm)

440

177

25

CO2 Sensor

300 5050

400

Ø 160

250

Ø 162

Water trap

Heat Recovery ventilation

Constant airflow kit

Constant pressure kit

500

767

718

Ø 150

288,5

112,7 112,7

140,

2

358,

2

103,9

5,5

112,

3

126

331,8

103,9

500

767

718

Ø 150

288,5

112,7 112,7

140,

2

358,

2

103,9

5,5

112,

3

126

331,8

103,9

150

235

111

150

150

235

111

150

Page 5: Dee Fly Cube 550 - Aldes International

5

Technical specifications Dee Fly Cube 550ELECTRICAL SPECIFICATIONS AVERAGE POWER CONSUMPTION• Power supply: 230 V - 50 Hz single-phase.• Maximum current: 2.5 A max.• Class : IP 54.

Airflow (m3/h) Pressure (Pa) Power consumption (W)123 928 355170 825 358227 722 362277 619 363324 516 360376 413 348426 311 333477 208 328528 105 325585 2 320

AIRFLOW SPECIFICATIONSConstant speed Constant pressure

Constant airflow

Heat Recovery ventilation

300

400

500

100

200

600

700

800

900

1000

100 200 300 400 500 6000

Speed 1Speed 2Speed 3

150

200

250

50

100

300

350

400

100 200 300 400 500 6000

Speed 1Speed 2Speed 3

W

300

400

500

100

200

600

100 200 300 400 500 6000

Speed 1Speed 2Speed 3

150

200

250

50

100

300

350

400

100 200 300 400 500 6000

Speed 1Speed 2Speed 3

W

300

400

500

100

200

600

700

800

900

1000

100 200 300 400 500 6000

Speed maxi.Spedd mini.Envelope curve

Test conditions at nominal airflow.• Outside air = -5 °C, Hr 80 %.• Ambient interior temperature = 20 °C, Hr 50 %.

ACOUSTIC SPECIFICATIONSTest conditions: (UNI EN ISO 3747).• Outdoor air = dry air at -5 °C, Hr 80%.• Indoor air = dry air at 20 °C, Hr 50%.• At maximum airflow : 585m3/h.

Dee Fly Cube 550 Sound power level in duct (Lw)

(Hz) 125 250 500 1000 2000 4000 8000 dB(A) dB(A) 63 64 71 68 66 58 52 73

Case breakout noise at 4m (Lp)(Hz) 125 250 500 1000 2000 4000 8000 dB(A)

dB(A) 38 39 48 40 39 29 18 47

Page 6: Dee Fly Cube 550 - Aldes International

6

Dee Fly Cube 550

• The Dee Fly Cube 550 can be fixed to the wall vertically.• Attachment bracket supplied with the Dee Fly Cube 550.• The Dee Fly Cube 550 must be installed in an insulated, frost-protected location.• Minimum width of maintenance hatch on front panel (500 mm).

Heat Recovery ventilation

INSTALLATION

• Air duct connections: 4 x Ø 150 mm branch connections (adapters Ø 160 mm included) + 4 sealed collars and 2 plugs.• Reversible connections: 4 branch connections on top or 2 on top / 2 on bottom.

• Connection of condensate discharge - Condensate discharge for connection to waste water network. - Water trap supplied in kit.

Attachment of slide Recess for opening front panel

Supply air (indoor)

Expulsion air (outdoor)

Exhaust air (indoor)

Fresh air (outdoor)

Page 7: Dee Fly Cube 550 - Aldes International

7

INSTALLATIONThe constant airflow or pressure kit features a ring to be positioned on air ducts; the pressurised air intakes must always be oriented downwards to prevent the introduction of dust or foreign bodies into the system, as they could cause it to malfunction.

Dee Fly Cube 550

Heat Recovery ventilation

Electrical connections:• Minimum cable cross-section: 3 x 1.5 mm2.• Power supply: 230 V single-phase.

CONSTANT AIRFLOWThe kit should be fitted on the exhaust air side (A) upstream of the fan unit to detect the differential pressure without risking the falsification of measurements by turbulence. If two kits are required, the other should be fitted on the fresh air side (B).

CONSTANT PRESSUREThe kit should be fitted on the exhaust air side (A) of the supply fan unit to detect the pressure downstream.

Positioning of pre-heating coil

Example of assembly of constant pressure kit Example of assembly of constant airflow kit

Connection of pre-heating coil The pre-heating coil must be attached horizontally.

Supply air (indoor)

Expulsion air (outdoor)

Exhaust air (indoor)

Fresh air (outdoor)

AB

Supply air (indoor)

Expulsion air (outdoor)

Exhaust air (indoor)

Fresh air (outdoor)

Supply air (indoor)

Expulsion air (outdoor)

Exhaust air (indoor)

Fresh air (outdoor)

A

Page 8: Dee Fly Cube 550 - Aldes International

8

SERVICING

Dee Fly Cube 550

Filter access (air supply and exhaust) Filters replacement:Variable according to pollution of ambient air (dust, smoke). Recommended every 6 months. Before changing the filters, turn the switch to position 0.

G4 filter (top)

Removing the maintenance panel

F7 filter (bottom)Description Code

Filters (1xG4 + 1xF7) 11023282

Heat Recovery ventilation

1

1

4

2

2

5

3

3

Page 9: Dee Fly Cube 550 - Aldes International

9

SERVICING

Dee Fly Cube 550

Access and cleaning the heat exchangerPrecautions to take when handling the exchanger.Recommended maintenance period for heat exchanger: approx. 12 months of operation.

Heat Recovery ventilation

1

4

2 3

Page 10: Dee Fly Cube 550 - Aldes International

10

REMOTE CONTROL DEE FLY CUBE 550 • 3-speed controller (30% - 65% - 100%). • Fan malfunction alarm.• Filter clogging alarm.• By-pass.• Dimensions : 90 x 90 x 60 mm.

REMOTE CONTROL DEE FLY CUBE 550+• Configurable ventilation speed.• Touch screen.• Boost function.• Fan malfunction alarm.• Filter clogging alarm.• By-pass.• Hourly and daily timer programming.• ModBus communication.• Dimensions : 120 x 80 x 25 mm.

Heat Recovery ventilationDee Fly Cube 550

Page 11: Dee Fly Cube 550 - Aldes International

11

SUMMARY OF REMOTE CONTROL FEATURESREMOTE CONTROLS CUBE 550 CUBE 550+

DESCRIPTION OF CONTROLS AVAILABILITY

VENTILATION

Fan speed

Choice of speed control: OFF – V1 – V2 – V3 X X

Choice of operating range - X

Automatic control of airflow by CO2 sensor X

Automatic control of fan speed by external 0-10 V signal - X

Remote ON / OFF contact - X

Boost function

Boost at set times - X

Boost configure by user - X

Boost by external contact, modifiable after activation - X

Boost by occupancy sensor - X

Time range

Weekly programming - X

COMFORT

Bypass

Automatic bypass control X X

Frost protection

Reduction of air supply fan speed down to zero. Increase of exhaust fan airflow up to maximum. X X

Control of electric pre-heating coil - X

ALARMS

Alarms

LED alarm / fault display X -

Flowchart alarm / fault display X

Remote display of unit operational status via remote contact: closed contact = unit ON / contact open = unit OFF - X

COMMUNICATION

Communication

Possibility of assigning master / slave - X

Possibility of changing display language: - English - Italian - French - German - Dutch - Spain

- X

ModBus communication - X

Heat Recovery ventilationDee Fly Cube 550

Page 12: Dee Fly Cube 550 - Aldes International

www.aldes.com

■ ALDES AÉRAULIQUE - Headquaters: Tel : +33 4 78 77 15 15 - Fax: +33 4 78 76 15 97 ■ ALDES INTERNATIONAL - Tel: +33 4 78 77 15 34 - Fax: +33 4 78 77 15 56

PrincipleHeat recovery ventilation offers general and uninterrupted ventilation, recovering the heat from exhaust air to pre-heat the influx of fresh air.

This type of ventilation filters incoming air and ensures clean air inside the dwelling.

Using the heat exchanger, new air is pre-heated to limit the need for indoor heating.

The Dee Fly Cube 550 unit can be easily installed in a cellar or equipment room.

Avantages• Reversible connections.

• Ventilation control via Interior Air quality sensors (CO2).

• Colour touch screen remote control.

• High-efficiency heat exchanger > 90 %.

• Energy-efficient motor.

Dee Fly Cube 550

Ventilation Double Flux

Dee

_fly

_cub

e_55

0_Te

ch_C

orp

_Gb

_1 -

06/

2015

- A

ldes

- A

ldes

res

erve

s th

e rig

ht t

o m

ake

chan

ges

to it

s p

rod

ucts

due

to

tech

nica

l dev

elop

men

ts. -

RC

S L

yon

956

506

828