_________________________________________________________________________________________ Decoder Verification Test Report - High Level Manufacturer Model Number Demodulator Market Operator Date Tested Build Date Software Version Driver Version Hardware Version Softcell Version Loader Version Flash Size x Ram Size Middleware Software DVB-S2 N8760B Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type CSHSKLH58101203 Czech Skylink 3-Dec-10 27-Nov-10 110 Not Stated 58 3.9.16 3.3 Standard security DVB over IP Advanced security CI CAM CI plus CSHSKLH58101203.xlsx 1

Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

_________________________________________________________________________________________Decoder Verification Test Report - High Level

Manufacturer

Model Number

Demodulator

Market

Operator

Date Tested

Build Date

Software Version

Driver Version

Hardware Version

Softcell Version

Loader Version

Flash Size x Ram Size

Middleware Software

DVB-S2

N8760B

Decoder Verification Test Report

For High level Code

Reference Number

COSHIP

16 x 256

Not Applicable

Multiview

SMD

DVT Type

CSHSKLH58101203

Czech

Skylink

3-Dec-10

27-Nov-10

110

Not Stated

58

3.9.16

3.3

Standard security

DVB over IP

Advanced security

CI CAM

CI plus

CSHSKLH58101203.xlsx 1

Page 2: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

_________________________________________________________________________________________Decoder Verification Test Report - High Level

High level DVT consists of two parts, those are, Integrated Loader

Tests and CA Tests. EPG functionality test isn't included in high

level DVT.

In the absence of an operator URS (User Requirement

Specification), the Softcell Integration Guide (#700295 or # 711886)

will be used as reference.

It is strongly advised that the Operator does extensive field trial

tests, specifically to assess the IRD performance, look and feel,

video and audio quality and general behaviour of the IRD.

Most of test cases are carried out based on bit streams. Advanced

test is based on Pisys.

Scope of Testing

CSHSKLH58101203.xlsx 2

Page 3: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

_________________________________________________________________________________________Decoder Verification Test Report - High Level

Brand: Version:

Brand: Model No:

Brand: Model No:

1)

2)

3)

RSA

Secure

Boot

Enable

JTAG

Locking

Enable

CW

Protected

IRD 1 Not Applicable Disabled Disabled Disabled

IRD 2 Not Applicable Disabled Disabled Disabled

IRD 3 Not Applicable Disabled Disabled Disabled

IRD 4 Not Applicable Disabled Disabled Disabled

IRD 5 Not Applicable Disabled Disabled Disabled

3. Start of Testing 29-Nov-10

1. Sign Off

1. Number of IRDs used during Test 5

2. Original Schedule Date 29-Nov-10

4. Hours used for Testing 40

5. Manufacturer binary code N8760B_DVT_1127.bin

6. Flash Configuration file CSHX_X3A_16M.cfg

7. Software Received 29-Nov-10

2. DVT performed on the following equipments

Bitstream Player:

Bluetop V7.4

Modulator:

Tandberg SM6625

Up-Converter:

Not Applicable Not Applicable

3. Notes:

This IRD do not have the secure Irdeto Loader. Manufacturer has supplemented their own

loader and as such, is responsible for any possible downloads to these IRDs

This IRD has Loader approval. Refer to Loader DVT report number:

CSHXL58100611

The current field software is:

1091

Software under test:

110

Softcell used:

Softcell 3 DVB Client (single decode) version 3.9.16 [coship, HW 58 Built 2010-09-01 15:03, release

Build].Built Sep 1 2010 at 15:04:59.

Details of IRDs used for this DVT:

CSSN (for

advanced security

device, HEX)

Secure related switches

(for advanced security device)

IRD Serial Number Flash Configuration

84000019390007 16 x 256

84000019390010 16 x 256

84000019390002 16 x 256

84000019390006 16 x 256

84000019390008 16 x 256

CSHSKLH58101203.xlsx 3

Page 4: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

_________________________________________________________________________________________Decoder Verification Test Report - High Level

4)

Version Type Patch Level Protocol Vendor ID IRD

2.2 Normal NA T=0 624 #1

6.0 Normal NA T=0 624 #1

4.1 Normal NA T=0 624 #2

5.4 Normal 9 T=0 624 #2

5.4 Normal 12 T=0 624 #2

5.0 Normal 3 T=0 624 #3

5.4 Normal 12 T=0 624 #3

5.3 Normal 8 T=0 604 #4

5.7 Normal NA T=0 624 #4

6.0 Normal NA T=0 624 #4

5.7 Normal 12 T=0 624 #5

Not Used Not Applicable -

Not Applicable Not Applicable -

Not Applicable Not Applicable -

Not Applicable Not Applicable -

Not Applicable Not Applicable -

Not Applicable Not Applicable -

5)

Bit Stream Version Version

OTA_Download V2.5 V2.5

SmartcardInit V2.5 V2.5

SmartcardTest V2.5 V2.5

SmartcardReset V2.5 V2.5

911mode V2.5 V2.5

DecoderTest V2.5 V2.5

StatusDisplay V3.3 V2.5

DriverTest V2.5 V2.5

CompLevelScramble V2.5 V2.5

FingerPrinting V2.5 NA

IRDMessage_00 V2.5 NA

IRDMessage_04 V2.5 V2.5

IRDMessage_01_MsgType05_Recovery00 NA MRBasicTest V2.5

IRDMessage_01_MsgType05_Recovery02 NA MRIppvTest NA

IRDMessage_01_MsgType05_Recovery05 NA SecureChipPair NA

TMSTest_network V2.5 SecureChipUnpair NA

TMSTest_transport V2.5 SOLTest NA

TMSTest_service V2.5 EMMStressSoakTest V3.5

Macrovison NA NA

IPPVTest NA

6) Details of Test Procedure used:

Doc No. Version

737549 DVT Automation Phase 3 6

730616

711417

730871 1.01.02

730652

734372

Smart Card 2 42000007221

Details of Smart Cards used:

Serial Number

Smart Card 1 40015493667

Smart Card 3 40064809524

Smart Card 4 40230957447

Smart Card 5 40277016156(Var 2_MR)

Smart Card 6 40088904293

Smart Card 7 40277016164(Var 2_MR)

Smart Card 8 40203249996

Smart Card 15 Not Applicable

Smart Card 16

Smart Card 9 41170170116(ICE_MR)

Smart Card 10 42000005381(T0CW)

Smart Card 11 41167050610

Smart Card 12 Not Applicable

Smart Card 13 Not Applicable

Smart Card 14 Not Applicable

Not Applicable

Smart Card 17 Not Applicable

SCMarriageNMarry

SCMarriageFMarry

Details of Bit Streams used:

Bit Stream

Rules for smart cards selecting:

a, For each version (2.2, 4.1, 5.0, 5.3, 5.7, 6.0), at least one card should be used in each test case.

b, V5.4 card should be used in 'smart card driver' and 'EMM soak test'.

c, At least one card with vendor ID = 604 should be used for all simulcrypted test bitstreams.

d, If both T=0 and T=14 are supported, each protocol should be covered. But it not necessary to have both

protocol for each version smart card (except for 'smart card driver' test).

SCMarriageUnmarry

SCMarriageVerify

SurfLocking

CustomCA

RSAChallenge

FlexiFlash

RunningStatus

HomingChannel

DVT Procedure for SoftCell 3 DVB Client

DVT PROCEDURE FOR SOFTCELL 3 DVB PVR

Homing_Channel_DVBS2

EnableMRConf

IPPV Test Procedure using PiSys

GenericMultipleSmartcard

Doc Name

High Level DVT Procedure for La7 IRDs

High Level DVT Procedure For IRD Software

CSHSKLH58101203.xlsx 4

Page 5: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

_________________________________________________________________________________________Decoder Verification Test Report - High Level

6)

Please note here if any operator requirement or specific pre-condition for the tests:

I - This model was originally registered as advanced security STB. However, Secure CW mode

was not enabled for this high-level DVT, which is known and accepted by Operator. Secure boot

and JTAG Port were enabled, which is the same as former loader DVT.

II - OTA download was performed with download service 02. When using download service 01,

following issues were observed:

- Valid EMM download was initiated successfully but the downloading was failed with the error

banner '80030038 - A timeout occurred whilst attempting to acquire a download section'

displayed on front panel during downloading progress.

- Valid menu driven OTA download was initiated successfully but the downloading was randomly

failed at the first time with the error banner '80030038 - A timeout occurred whilst attempting to

acquire a download section' displayed on front panel during downloading progress. Then menu

driven OTA download was successful by reinitiating. This was occurred 50%.

Notes for all test cases:

CSHSKLH58101203.xlsx 4

Page 6: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

TestCase Result Remark

Step01 Pass

Step02 Pass

Pass

Step03 Untested

Step04 Pass

Step05/06/07 Pass

Pass

Step08/09

case001 Pass

case002 Pass

case003 Pass

case004 Pass

case005 Pass

case006 Pass

case007 Pass

case008 Pass

case009 Pass

case010 Pass

case011 Pass

case012 Pass

case013 Pass

case 014 Pass

Pass

case015 Pass

Pass

case016 Pass

Pass

case 017 Pass

Pass

case018 Pass

Pass

case019 Pass

Pass

Step10 Pass

Fail

The build date of software was not consistent with manufacture's input document.

The build date was 'Nov 25 2010' on loader status menu but in manufacture's input

document it was '2010-11-27'.

Step11 Untested

The OTA Download was not implemented when the STB was in standby mode.

This was stated in the manufacturer's input.

Quote:

When the STB is in standby mode, we cannot implement the OTA and receive the

messages, as we should reduce the power dissipation according the provision of

European Union. So we turn off most of the hardware component in the standby

mode. The statement from SkyLink is attached with the firmware.

EMM/CtrlByte=02 - enhanced linkage descriptor

same load ver. - standard&enhanced linkage descriptor

load ver. + 1 - standard&enhanced linkage descriptor

wrong MFC ID - standard linkage descriptor

menu/CtrlByte=02 - standard linkage descriptor

EMM/CtrlByte=02 - standard linkage descriptor

load ver. + 99 - enhanced linkage descriptor

menu/CtrlByte=00 - standard linkage descriptor

correct MFC ID - standard linkage descriptor

wrong MFC ID - enhanced linkage descriptor

wrong HW Ver. - enhanced linkage descriptor

wrong variant - enhanced linkage descriptor

menu/CtrlByte=01 - standard linkage descriptor

Customer settings

Upgrade to DVT S/W directly (if step01 & step02 are untested)

Reject current version S/W

Reject a menu upgrade - CRC error

Reject EMM upgrade - CRC error

OTA DOWNLOAD

Description

Upgrade to infield S/W

Upgrade from infield S/W to DVT S/W

Download in standby mode

Items on Loader Status Menu

OTA_Download.mpg

menu/CtrlByte=00 - enhanced linkage descriptor

EMM/CtrlByte=00 - enhanced linkage descriptor

menu/CtrlByte=01 - enhanced linkage descriptor

EMM/CtrlByte=01 - enhanced linkage descriptor

menu/CtrlByte=02 - enhanced linkage descriptor

EMM/CtrlByte=00 - standard linkage descriptor

Cross transponders download

load ver. + 100 - enhanced linkage descriptor

load ver. + 1 - enhanced linkage descriptor

load ver. - enhanced linkage descriptor

wrong HW ver. - standard&enhanced linkage descriptor

wrong variant - standard&enhanced linkage descriptor

EMM/CtrlByte=01 - standard linkage descriptor

CSHSKLH58101203.xlsx

Page 7: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

TestCase Description

SMARTCARD TEST

Service 101:

Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:10 E16 E16-4 Pass

0:10 ~ 0:50 E29 D29-4 Pass

Service 101:

Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 1:40 E29 D29-4 Pass

Pass

Pass

Pass

Pass

Service 101:

Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:40 E29 D29-4 Pass

0:40 ~ 0:50 E16 E16-4 Pass

DECODER TEST

Service 101 / 102:

Step01 Time

Step02 (m:ss) SCell 2 Scell 3

0:00 ~ 0:10 E00 D100-8 Pass

0:10 ~ 1:50 E29 D29-4 Pass

Pass

1:50 ~ 2:00 E00 D100-8 Pass

Service 101 / 102:

Time

Step01 Switch to service 101 (HD). (m:ss) SCell 2 Scell 3

Video running smoothly all over. 0:00 ~ 0:20 E00 D100-8 Pass

Get different audio tracks (if supports). 0:20 ~ 2:10 E29 D29-4 Pass

Step02 Switch to service 102 (SD). 2:10 ~ 2:30 E00 D100-8 Pass

Video running smoothly all over. Untested

Get different audio tracks (if supports). Untested

CA FEATURES TEST

Initialize all the smartcards.

Different audio tracks on svc 102

SmartcardReset.mpg

Remove smartcard and re-inserted after 10s

Video returns after smart cards reinserted.Result

DecoderTest.mpg

Result

SmartcardInit.mpg

Video running smoothly all over.

911Mode.mpg

SmartcardTest.mpg

Remark

Remark

ErrorCodes

ErrorCodes

Different audio tracks on svc 101

RemarkErrorCodes

Result RemarkErrorCodes

Power cycle without smartcard inserted

Power cycle with smartcard inserted

Switching service

Smartcard inserted incorrectly

Result

Result

ErrorCodes

Restore all the smartcards.Remark

CSHSKLH58101203.xlsx

Page 8: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-0

StatusDisp

lay.mpg Service 101:

V2/V4 V5.0 V5.3/5.4/5.7 V6 V2/V4 V5.0V5.3/5.4

/5.7V6

V5.7 and

/or lower V6

0:00~0:20 E17 E00/E--[[4]] E00/E-- E17>E30[[5]] E101-4 E16-4 E109-4 E101-4 E16-4 E101-4

0x--/0x-- 0x6A/0x6A >E16[[6]] >E30-4[7]>E30-4>E16-

4[[8]]

0:20~0:40 E29 E29 E29 E29 D29-4 D29-4 D29-4 D29-4 D29-4 D29-4 Pass

0:40~1:00 E17 E29 E29 E16[9] E101-4 E16-4 E109-4 E30-4 E16-4D29-4 with

black screen

0x--/0x-- 0x6A/0x6A /E30 /E16-4[10]

1:00~1:20 E29 E29 E29 E29 D29-4 D29-4 D29-4 D29-4 D29-4 D29-4 Pass

1:20~1:40 E17 E29 E29 E16>E30 E101-4 E16-4 E109-4 E30-4> E16-4

D29-4 with

black screen

/E16-4[13]

0x--/0x-- 0x6A/0x6A >E17[[11]] E101-4[12] >E101-4

Pass

Pass

Pass

Service 102:

V2/V4 V5.0 V5.3/5.4/5.7 V6 V2/V4 V5.0V5.3/5.4

/5.7V6

V5.7 and

/or lower V6

0:00~0:20 E00 E00 E00 E00 D100-8 D100-8 D100-8 D100-8 D100-8 D100-8 Pass

0:20~0:40 E17 E00/E-- E00 E16[14] E101-4 E16-4 E109-4 E30-4 E16-4

I34-9 with

black screen

/E16-4 [15]

0x--/0x-- 0x6D /0x6D /E30

0:40~1:00 E29 E29 E29 E29 D29-4 D29-4 D29-4 D29-4 D29-4 D29-4 Pass

1:00~1:20 E00 E00 E00 E00 D100-8 D100-8 D100-8 D100-8 D100-8 D100-8 Pass

1:20~1:40 E17

E29/E00 E00 E16/E30

E101-4 E16-4 E109-4

E30>

E16-4

I34-9 with

black screen

/E16-4 [18]

0x--/0x-- 0x6D /0x6D >E17[[16]] E101-4[17] > E101-4Pass

Pass

Pass

Pass

SoftCell 3.6.25 ~ 3.6.28

SoftCell 3.8 and/or higherRemark

SoftCell 3.7

Pass

STATUS DISPLAY TEST

ECM PID & monitoring sections update

EMM monitor data update dynamically

Mandatory Items are included on status screen

Nationality update

SoftCell2.xSoftCell 3.6.24 and/or lower

SoftCell 3.7

Expected ErrorCodes

ECM PID & monitoring sections update

EMM monitor data update dynamically

Mandatory Items are included on status screen

Time

(m:ss)

Time

(m:ss)

Expected ErrorCodes

SoftCell 3.6.24 and/or lower

Pass

Result

Result Remark

SoftCell 3.6.25 ~ 3.6.28

SoftCell 3.8 and/or higher

Pass

Pass

Pass

SoftCell2.x

CSHSKLH58101203.xlsx

Page 9: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-1

DRIVER TEST

Service 101:

Step01 Time

(m:ss) SCell 2 SCell 3

Scrambled with product_0 and block_0~block_7 on sector_0

0:00 ~ 0:20 E16 E16-4 Pass

0:20 ~ 0:40 E29 D29-4 Pass

0:40 ~ 1:00 E18 E18-4 Pass

1:00 ~ 1:20 E16 E16-4 Pass

1:20 ~ 1:40 E18 E18-4 Pass

Scrambled with multi-products on different sectors

1:40 ~ 2:00 E00 D100-8 Pass

2:00 ~ 3:20 E29 D29-4 Pass

Scrambled with product_0~product_9 on sector_0

3:20 ~ 3:30 E00 D100-8 Pass

3:30 ~ 5:00 E29 D29-4 Pass

5:00 ~ 5:20 E00 D100-8 Pass

Pass

RemarkVideo & Error banners

DriverTest.mpg

Products on the smartcardsErrorCodes

Result

Products on the smart cards

CSHSKLH58101203.xlsx

Page 10: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-2

COMPONENT LEVEL SCRAMBLE TEST

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 30:00 ~ 0:20 E00 D100-8 Untested

0:20 ~ 0:40 E16 E16-4 Untested

0x50/0x1d E16-4/D29-4 Untested

E29 D29-4 Untested

0x1d/0x1d D29-4/D29-4 Untested

E16 E16-4 Untested

0x50/0x1d E16-4/D29-4 Untested

E29 D29-4 Untested

0x1d/0x1d D29-4/D29-4 Untested

E16 E16-4 Untested

0x1d/0x50 D29-4/E16-4 Untested

2:00 ~ 2:20 E00 D100-8 Untested

Untested

Step02 Service 102:

Time

(m:ss) SoftCell 2 SoftCell 30:00 ~ 0:20 E00 D100-8 Pass

E16 E16-4 Pass

0x50/0x1d E16-4/D29-4 Pass

E29 D29-4 Pass

0x1d/0x1d D29-4/D29-4 Pass

E16 E16-4 Pass

0x50/0x1d E16-4/D29-4 Pass

E29 D29-4 Pass

0x1d/0x1d D29-4/D29-4 Pass

E16 E16-4 Pass

0x1d or

0x50/0x50

E16-4/E16-4

Pass

2:00 ~ 2:20 E00 D100-8 Pass

Pass

1:00 ~ 1:20

1:20 ~ 1:40

1:40 ~ 2:00

2 x ECM PID & monitoring sections update

Audio and Video & Error Banners

2 x ECM PID & monitoring sections update

Global service status on Descramble Service Status Menu

Video & Error BannersResult

ErrorCodes

0:20 ~ 0:40

Same as above.

0:40 ~ 1:00

Global service status on Descramble Service Status Menu

CompLevelScramble.mpg

0:40 ~ 1:00

1:00 ~ 1:20

ErrorCodes

1:20 ~ 1:40

Remark

Remark

This test case is only available for cable IRDs in China market.

Same as above.

2 x ECM PID & monitoring sections update

2 x ECM PID & monitoring sections update

Result

1:40 ~ 2:00

Same as above.

Same as above.

Same as above.

Same as above.

Same as above.

Same as above.

Same as above.

Same as above.

Same as above.

Same as above.

CSHSKLH58101203.xlsx

Page 11: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-3

FINGER PRINTING TEST

Service 101:

Step01

Pass

Cover FingerPrinting attributes Pass

Pass

Attributes of ADM Pass

Pass

Display_method Pass

Pass

Highest priority of finger printing Fail

Fail

Service 102:

Step02

Cover FingerPrinting attributes

Pass

Pass

Pass

Fingerprinting was not observed when 'Installation' menu was entered.

I - The title was observed for all overt fingerprinting at 11s, 120s, 160s and 186s.

The overt fingerprinting was expected to be displayed without title.

II - The text size of overt fingerprinting was not match with the size of

background.

III - Fingerprinting/ADM at 0:11 was not displayed as expected:

i - The font color was black and the background color was green. The font color

was expected to be green and the background color was purple.

ii - The font and background were not transparent. The expected was

semitransparent.

iii - The fingerprinting was displayed on whole screen. Expected was that they

were displayed 100% of banner width versus screen width due to 'coverage=63'.

IV - The attribute of fingerprinting at 0:40 was not displayed as expected:

i - The fingerprinting type was covert. It was expected to be overt.

ii - The duration was 30s but the expected was 10s.

iii - The fingerprinting was flashed, however it was expected to be not flashed.

V- The fingerprinting at 1:20 and 3:06 were not displayed as expected:

i - The font color was black. The expected was orange.

ii - The font and background were not transparent. The expected was

semitransparent.

iii - The fingerprinting at 3:06 was displayed on whole screen. Expected was that

they were displayed 100% of banner width versus screen width due to

'coverage=63'.

Attributes (duration; Flashing;)

FingerPrinting.mpg

Verify the highest priority of finger printing via ECM

Over FingerPrinting attributes

Over FingerPrinting attributes

FingerPrinting via ECM at 40s,80s,120s and 160s

FingerPrinting via EMM at 11s,186s and 200s

FingerPrinting via EMM at 11s,186s and 200s

Duration

Attributes of ADM

Duration

FingerPrinting via EMM at 186s

FingerPrinting via EMM at 186s

Item

FingerPrinting via ECM at 120s

FingerPrinting via ECM at 160s

FingerPrinting via ECM at 40s

FingerPrinting via ECM at 80s

Remark

RemarkResult

Result

FingerPrinting via EMM at 11s

Item

FingerPrinting via EMM at 11s

FingerPrinting via EMM at 200s

FingerPrinting via EMM at 200s

CSHSKLH58101203.xlsx

Page 12: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

MAIL / ANNOUNCEMENT MESSAGE TEST

Service 101 / 102:

Step01 Forced announcement on clear service 101/102

Normal announcement on clear service101/ 102

Forced mail on clear service 101/102 Pass

maximum size announcement(255 bytes) on clear service Pass

101/102 Pass

Normal mail on clear service 101/102 Pass

maximum size mail (255 bytes)on clear service 101/102 Pass

Pass

Pass

Loader info consistency Pass

step02 Untested

Untested

The OTA Download was not implemented when the STB was in standby mode.

This was stated in the manufacturer's input.

Quote:

When the STB is in standby mode, we cannot implement the OTA and receive

the messages, as we should reduce the power dissipation according the

provision of European Union. So we turn off most of the hardware component in

the standby mode. The statement from SkyLink is attached with the firmware.

Same as above.Standby-mode on service 102

Attributes (forced and normal)

Forced announcement

IRDMessage_00.mpg

Forced mail

Normal mail

Result

Maximum size announcement

Remark

Standby-mode on service 101

Attributes(Forced and Normal)

Text message receiving in standby

Item

Maximum size mail

Normal announcement

CSHSKLH58101203.xlsx

Page 13: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-4

ATTRIBUTED DISPLAY MESSAGE TEST

Service 101:

Step01

Pass

Pass

Pass

Pass

Pass

Pass

Step02 Service 102:

Pass

Pass

Pass

Pass

Pass

Pass

DECODER CONTROL MESSAGE TEST

Service 101:

Untested

Service 101:

Untested

Service 101:

Untested

This was stated in the manufacturer's input:

Quote:

10. DECODER CONTROL MESSAGE TEST

III. IRDMessage_01_MsgType05_Recovery05.mpg: Untested

Remark

Remark

Remark

This was stated in the manufacturer's input:

Quote:

10. DECODER CONTROL MESSAGE TEST

I. IRDMessage_01_MsgType05_Recovery00.mpg: Untested

This was stated in the manufacturer's input:

Quote:

10. DECODER CONTROL MESSAGE TEST

II. IRDMessage_01_MsgType05_Recovery02.mpg: Untested

Remark

Remark

Attributes of ADM

Duration

Normal ADM on scrambled service 101

Duration

Display method

IRDMessage_01_MsgType05_Recovery02.mpg

Re-scan & reset channel order

Forced maximum size ADM

Normal ADM

Normal maximum size ADM

Result

Forced Attribute Display Message

Result

Item

Reset IRD

Item

Result

Force tune to service 102

Result

Normal maximum size (511 bytes) ADM on clear service 102

Forced ADM on scrambled service 101

Forced maximum size(511 bytes) ADM on scrambled service 101

IRDMessage_04.mpg

Display_method

Normal ADM on clear service 102

ItemForce tune to service 102

Forced maximum size (511 bytes) ADM on clear service 102

Forced ADM on clear service 102

Normal maximum size(511 bytes) ADM on scrambled service 101

Attributes of ADM

IRDMessage_01_MsgType05_Recovery05.mpg

Attributes of ADM & duration

Display_method

Display_method

Forced maximum size ADM

Normal ADM

Reset channel order

Item

Item

Forced Attribute Display Message

IRDMessage_01_MsgType05_Recovery00.mpg

Reset IRD

Attributes of ADM & duration

Normal maximum size ADM

Result

CSHSKLH58101203.xlsx

Page 14: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-5

TMS TEST

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 3Pass

Pass

Pass

Pass

Step02 Service 102:

Time

(m:ss) SoftCell 2 SoftCell 3Pass

Pass

Pass

Pass

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 3Pass

Pass

Pass

Pass

Step02 Service 102:

Time

(m:ss) SoftCell 2 SoftCell 3Pass

Pass

Pass

Pass

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 3Pass

Pass

Pass

Pass

Pass

Step02 Service 102:

Time

(m:ss) SoftCell 2 SoftCell 3Pass

Pass

Pass

Pass

Pass

Remark

Remark

Remark

Remark

Remark

Remark

TMSTest_service.mpg

Get fingerprinting on service 102

Get attribute display message on service 102

Get fingerprinting on service 101

Get attribute display message on service 102

ErrorCodes

Attribute display message received

Method

Result

Result

Attribute Type

Finger printing received

Result

Result

ErrorCodes

Duration

Method

Method

Attribute display message received

Finger printing received

Attribute

Result

Type

Attribute display message received

Duration

Method

Attribute display message received

ErrorCodes

Result

Get attribute display message on service 102

Get attribute display message on service 101

TMSTest_network.mpg

TMSTest_transport.mpg

Get attribute display message on service 101

Get attribute display message on service 101

ErrorCodes

ErrorCodes

Attribute

Type

Duration

Duration

Method

Method

Type

Attribute display message received

Attribute Type

Duration

Attribute display message received

ErrorCodes

Attribute Type

Attribute

Duration

CSHSKLH58101203.xlsx

Page 15: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-6

SCMARRIAGE TEST

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:10 E16 E16-4 Pass

0:10 ~ 0:50 E29 D29-4 Pass

Pass

Service 101:

Step02&03 Time

(m:ss) SoftCell 2 SoftCell 3Step04 0:00 ~ 1:40 E17/E29 E17-13/D29-4 Pass

Step05 Pass

Pass

Service 101:

Step06&07 Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:10 E16 E16-4 Pass

0:10 ~ 0:50 E29 D29-4 Pass

Service 101:

Step08 Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 1:40 E17/E29 E17-13/D29-4 Pass

Service 101/102:

Step09 Result

Pass

Service 101:

Step10 Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 1:40 E17/E29 E17-13/D29-4 Pass

Service 101:

Step11 Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:40 E29/E16 D29-4/E16-4 Pass

0:40 ~ 0:50 E16 E16-4 Pass

Remark

Remark

Remark

Remark

Remark

Remark

Remark

SCMarriageVerify.mpg

check the marriage status is the same as in step08

Forced marry & marriage status

OTA_Download.mpg

update the sw in the STB using case10, or case02/08 in step09

SCMarriageUnMarry.mpg

Marriage Status Message

SCMarriageNMarry.mpg

E17

Marriage Status Message

No change of marriage status after power cycle

Marry

SCMarriageFMarry.mpg

No change of marriage status after restore factory settings

Un-marry

SCMarriageVerify.mpg

Result

Result

ErrorCodes

Smartcard marriage status

ErrorCodes

ErrorCodes

ErrorCodes

After power cycle

After restore factory settings

ErrorCodes

Expected Behavior

Result

Result

Result

ErrorCodes

Result

STB is upgraded with a new version S/W

SCMarriageVerify.mpg

insert smart card to the original STB

CSHSKLH58101203.xlsx

Page 16: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-7

FLEXIFLASH TEST

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:20 E00 D100-8 Pass

0:20 ~ 0:40 E30 E108-4 Pass

0:40 ~ 1:00 E16 E16-4 Pass

CUSTOMIZED CA TEST

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:20 E00 D100-8 Pass

0:20 ~ 0:40 E80 E80-35 Pass

0:40 ~1:00 E29 D29-4 Pass

1:00 ~ 1:20 E81 E81-35 Pass

1:20 ~ 1:40 E29 D29-4 Pass

1:40 ~ 2:00 E00 D100-8 Pass

RSA CHALLENGE TEST

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:20 E16 E16-4 Pass

0:20 ~ 0:35 E29 D29-4 Pass

0:35 ~ 0:55 E33 E33-4[[1]] Pass

0:55 ~ 1:10 E29 D29-4[[2]] Pass

SURF LOCKING TEST

Service 101 / 102:

Step02 TimeStep03 (m:ss) SoftCell 2 SoftCell 3Step04 0:00 ~ 1:00 E00 D100-8 Pass

1:00 ~ 4:00 E29/E32 D29-4/E32-4 Pass

Step05 Pass

Pass

Pass

Pass

Pass

4:00 ~ 5:00 E00 D100-8 Pass

E29/D29-4 after re-insert smartcard

Remark

Remark

Remark

Remark

RSAChallenge.mpg

Video & Error banners on service 101

Video & Error banners on service 101 ErrorCodes

Result

ResultErrorCodes

ErrorCodes

Get E32 after 2 times switch channel

Get D29 after extract and put back smartcard

Get E32 after 7 times switch channel

E32/E32-4 after 7 times switching channel

Result

ErrorCodes

E32/E32-4 after 7 times switching channel

CustomCA.mpg

Video & Error banners on service 101

E32/E32-4 after 2 times switching channel

Result

Flexiflash.mpg

SurfLocking.mpg

Get E32 after 7 times switch channel

Get D29 when enter second crypto period

E29/D29-4 during 120-180s

CSHSKLH58101203.xlsx

Page 17: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-8

RUNNING STATUS TEST

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:20 E16 E16-4 Pass

0:20 ~ 0:40 E38 E38-32 Pass

0:40 ~ 1:00 E16 E16-4 Pass

1:00 ~ 1:20 E38 E38-32 Pass

1:20 ~ 1:40 E16 E16-4 Pass

1:40 ~ 2:00 E38 E38-32 Pass

2:00 ~ 2:20 E29 D29-4 Pass

2:20 ~ 2:40 E38 E38-32 Pass

2:40 ~ 3:00 E29 D29-4 Pass

3:00 ~ 3:20 E38 E38-32 Pass

3:20 ~ 3:40 E29 D29-4 Pass

3:40 ~ 4:00 E38 E38-32 Pass

Step02 Service 102:

Time

(m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:20 E00 D100-8 Pass

0:20 ~ 0:40 E38 E38-32 Pass

0:40 ~ 1:00 E00 D100-8 Pass

1:00 ~ 1:20 E38 E38-32 Pass

1:20 ~ 1:40 E00 D100-8 Pass

1:40 ~ 2:00 E38 E38-32 Pass

2:00 ~ 2:20 E00 D100-8 Pass

2:20 ~ 2:40 E38 E38-32 Pass

2:40 ~ 3:00 E00 D100-8 Pass

3:00 ~ 3:20 E38 E38-32 Pass

3:20 ~ 3:40 E00 D100-8 Pass

3:40 ~ 4:00 E38 E38-32 Pass

CONT.-9

HOMING CHANNEL TEST

Service 101:

Step01 Time

(m:ss) SoftCell 2 SoftCell 3

Untested

Untested

RunningStatus.mpg

Remark

running status = 3 on E16-4

running status = 2 on E16-4

Remark

This was stated in the manufacturer's input:

Quote:

18.HOMINGCHANNEL.MPG

a) Homing Channel Download on Smart Card: Untested

This was stated in the manufacturer's input:

Quote:

18.HOMINGCHANNEL.MPG

b) Homing Channel Functionality: Untested

Remark

running status = 4 on D100-8

ErrorCodesResult

ErrorCodesResult

Homing channel parameter on smartcard

running status = 4 on E16-4

running status = 1 on D29-4

running status = 1 on E16-4

running status = 4 on D29-4

Homing channel functionality

ResultErrorCodes

running status = 3 on D29-4

running status = 2 on D29-4

running status = 3 on D100-8

HomingChannel.mpg

Homing Channel verifying

running status = 2 on D100-8

running status = 1 on D100-8

CSHSKLH58101203.xlsx

Page 18: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

Service 101:

V2/V4 V5.0 V5.3/5.4/5.7 V6 V2/V4 V5.0V5.3/5.4

/5.7V6

V5.7 and

/or lowerV6

0:00~0:20 E00 E00 E00 E00 D100-8 D100-8 D100-8 D100-8 D100-8 D100-8 Pass

0:20~0:30 E17 E17[[28]] E00/E-- E16[29] E101-4 E16-4 E109-4 E30-4 E16-4

I34-9 with

black screen

/E16-4[30]

0x51/0x1D 0x6A/0x6A /E30

0:30~1:10 E29 E29 E29 E29 D29-4 D29-4 D29-4 D29-4 D29-4 D29-4 Pass

1:10~1:30 E17 E17/E-- E29/E-- E16[31] E101-4 E16-4 E109-4 E30-4 E16-4[32]

D29-4 with

black screen

/E16-4[33]

0x51/0x1D 0x6A/0x6A /E30

1:30~1:50 E29/E38 E29/E38 E29/E38 E29/E38 D29-4 /E38-32D29-4 /E38-

32D29-4 /E38-32 D29-4 /E38-32 D29-4 /E38-32 D29-4/E38-32

Pass

1:50~2:00 E00 E00 E00 E00 D100-8 D100-8 D100-8 D100-8 D100-8 D100-8 Pass

Pass

Pass

Pass

Service 102:

V2/V4 V5.0 V5.3/5.4/5.7 V6 V2/V4 V5.0V5.3/5.4

/5.7V6

V5.7 and

/or lowerV6

0:00~0:20 E00 E00 E00 E00 D100-8 D100-8 D100-8 D100-8 D100-8 D100-8 Pass

0:20~0:30 E17 E17/E-- E00/E-- E16[34] E101-4 E16-4 E109-4 E30-4 I34-9 > E16-4

I34-9 with

black screen

/E16-4[36]

0x--/0-- 0x6A/0x6A /E30 or E16

0:30~1:10 E29 E29 E29 E29 D29-4 D29-4 D29-4 D29-4 D29-4[35] D29-4 Pass

1:10~1:30 E17 E17/E29/E-- E29/E-- E29>E16 E101-4 E16-4 E109-4 E30-4 D29-4>E16-4

D29-4 with

black screen

/E16-4[38]

0x6A/0x6A /E30[37] or E16

1:30~1:50 E29/E38 E29/E38 E29/E38 E29/E38 D29-4 /E38-32D29-4 /E38-

32D29-4 /E38-32 D29-4 /E38-32 D29-4 /E38-32 D29-4/E38-32

Pass

1:50~2:00 E00 E00 E00 E00 D100-8 D100-8 D100-8 D100-8 D100-8 D100-8 Pass

Pass

Pass

Pass

Pass

SoftCell 3.8 and/or higher

Expected ErrorCodes

ResultSoftCell2.x

SoftCell 3.6.24 and/or lower SoftCell 3.6.25 ~ 3.6.28

SoftCell 3.8 and/or higher Remark

Pass

RemarkResult

Pass

EMM STRESS SOAK TEST

Normal announcements

Performance after 12 hours

Switching channels after 12 hours

Expected ErrorCodes

SoftCell2.xSoftCell 3.6.24 and/or lower

SoftCell 3.7

SoftCell 3.6.25 ~ 3.6.28

Normal announcements

Time

(m:ss)

Performance after 12 hours

Switching channels after 12 hours

Pass

EMMStressSoak.mpg

Time

(m:ss)SoftCell 3.7

CSHSKLH58101203.xlsx

Page 19: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-10

Service 101:

Time

(m:ss) SoftCell 2 SoftCell 3Initialize 2 v5.4 patch level 12 (or higher) cards, or 2 ICE2 smartcards. 0:00 ~ 0:20 E16 E16-4 Pass

0:20 ~ 0:40 E29 D29-4 Pass

Set user profile(s). Pass

Service 101 / 102:

Svc101: MR level in ECM =9 Time

Svc102: MR level in ECM =12 (m:ss) SoftCell 2 SoftCell 3

0:00 ~ 1:40 N/A D29-4/E136-4 Pass

Pass

Switch to svc102: 'maturity rating block outs' Pass

For v5.4 cards:

Enter pwd of profile 1: 'maturity rating block outs' Pass

Enter pwd of profile 2: AV of svc102 Pass

For ICE2 cards:

Enter invalid pwd: 'maturity rating block outs' Pass

Enter correct pwd: AV of svc102 Pass

For both v5.4 and ICE2 cards:

Zap channels and AV running on both service Pass

Reinsert cards, switch to svc101, AV running Pass

Switch to svc102: 'maturity rating block outs' again Pass

For v5.4 cards:

Disable maturity rating on the IRD Pass

AV running on svc102 Pass

Enable maturity rating Pass

AV blocked on svc102: 'maturity rating block outs' Pass

Service 101 / 102:

Svc101: MR level in ECM =6 Time

Svc102: MR level in ECM =12 (m:ss) SoftCell 2 SoftCell 3

0:00 ~ 0:50 E23 / E25 D23-12/D25-12

Untested

0:50 ~ 1:40 E24 / E25 D24-12/D25-12 Untested

Untested

Check IPPV purchase menu (if supports) Untested

Switch to svc102: 'maturity rating block outs' Untested

For v5.4 cards:

Enter pwd of profile 1: 'maturity rating block outs' Untested

Enter pwd of profile 2: expected result Untested

For ICE2 cards:

Enter correct pwd to get expected result Untested

For both v5.4 and ICE2 cards:

Zap channels and AV running on both service Untested

Reinsert cards, switch to svc101: expected result Untested

Switch to svc102: 'maturity rating block outs' again Untested

Same as above.

Same as above.

Same as above.

Same as above.

Remark

Same as above.

Same as above.

Same as above.

Same as above.

Same as above.

Remark

This was stated in the manufacturer's input:

Quote:

20.MATURITY RATING TEST

III.MRIppvTest.mpg: Untested

Same as above.

Remark

Result

MATURITY RATING TEST

EnableMRConf.mpg

ErrorCodes

For v5.4 cards: set 2 user profiles-level 11 and 14MRBasicTest.mpg

ErrorCodesResult

Tune to svc101: 'No maturity rating block outs'

Result

Tune to svc101: 'No maturity rating block outs'

MRIppvTest.mpg

ErrorCodes

CSHSKLH58101203.xlsx

Page 20: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

CONT.-11

Service 101:

Step01

V5.3/5.4/5.7 V6 V5.3/5.4/5.7 V6 V5.3/5.4/5.7 V6

0:00~0:10 E107-4 E107-4 E107-4 E107-4 E16-4

E101-4 >E30-

4[42] Untested

0:10~0:20 D29-4 D29-4 D29-4[[43]] D29-4[[44]] D29-4 D29-4 Untested

0:20~0:30 E109-4 E30-4>E101-4 E16-4 E30-4[45] >E101-4 E16-4

E16-4[46]

>E101-4 Untested

Service 101:

Step02

V5.3/5.4/5.7 V6 V5.3/5.4/5.7 V6 V5.3/5.4/5.7 V6

0:00~0:10 E109-4 E101-4>E30-4 E16-4 E101-4>E30-4 E16-4

E101-4 >E30-

4[47] Untested

0:10~0:20 E107-4 E107-4 E107-4 E107-4 D29-4 D29-4 Untested

0:20~0:30 E107-4 E107-4 E107-4 E107-4 E16-4

E16-4[48]

>E101-4 Untested

Service 101:

Time

(m:ss)Step01 0:00 ~ 0:20 Untested

Step02 0:20 ~ 0:40 Untested

Step03 0:40 ~ 1:10 Untested

Step04 1:10 ~ 1:20 Untested

Step05 1:20 ~ 1:30 Untested

SoftCell 3.10 running on

Dual Mode

SoftCell 3.10 running on

SoftCell 3.8, and/or higher

Time

(m:ss)

Error Codes

SoftCell 3.6.24 and/or lower SoftCell 3.6.25 ~ 3.6.28

SoftCell 3.7 SoftCell 3.8, and/or higher Dual Mode

SecureChipUnpair.mpg

Same as above.

Same as above.

Same as above.

Result

Result

Remark

This test case is only available for advanced security IRDs.

See Note I.

Same as above.

Same as above.

Remark

Result RemarkSCell3

ADVANCED SECURITY STB

SecureChipPair.mpg

PERSIST STORAGE TEST

This bitstream is used for IRDs which do not support SCMarriage function.

Same as above.

Same as above.

Check Video/CA state transition.

Error CodesTime

(m:ss)

SoftCell 3.6.24 and/or lower

SoftCell 3.7

SoftCell 3.6.25 ~ 3.6.28

Play-out the OTA_Download.mpg, and scan service information.

Pause the playing-out at 50~60 seconds, restore factory settings on the

Pause the playing-out at 50~60 seconds, then power cycle the IRDs,

Same as above.

Same as above.

PS_CILAYER.mpg

Perform the test step10 in Appendix D.

E16-4

D29-4

E33-4

D29-4

E16-4

Error Codes

CSHSKLH58101203.xlsx

Page 21: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

Result Remark

Pass

Untested This test case is only available for MCA operator

Untested

This was stated in the manufacturer's input:

Quote:

24. ADDITIONAL TESTS

IV. PVR

a) PVR Record: Untested

Untested

This was stated in the manufacturer's input:

Quote:

24. ADDITIONAL TESTS

IV. PVR

b) PVR Playback: Untested

Untested

This was stated in the manufacturer's input:

Quote:

21. SOLTEST.MPG

a) STB Operator Locking: Untested

Untested

This was stated in the manufacturer's input:

Quote:

24. ADDITIONAL TESTS

V. IPPV: Untested

Untested

This function was not supported according to the

manufacturer's input.

Note:

The above cases were tested by the following head-end:

2.16.1.2 configuration in Simulcrypted mode Si generated

ADVANCED TEST

Test case

I. Regionalization

II. Parental Control

III. PVR

a) PVR Record

b) PVR Playback

by Pisys.

PIsys build      

V. IPPV

IV. SOL

VI. LPPV

CSHSKLH58101203.xlsx

Page 22: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

Decoder Verification Test Report - High Level

GENERAL ISSUES

Issues reported under the 'General Issues' are some common issues which can't be

included in the above test cases.

CDI engineer will make a decision if Issues reported in this section lead to failure of DVT.

CSHSKLH58101203.xlsx

Page 23: Decoder Verification Test Report For High level Code · Decoder Verification Test Report For High level Code Reference Number COSHIP 16 x 256 Not Applicable Multiview SMD DVT Type

_________________________________________________________________________________________Decoder Verification Test Report - High Level

Signature: Date: 12/21/2010SENIOR ENGINEER

(Stamp in appropriate Test Result block above)

Test result is based on the softcell integration guide or specific

operator user requirement specifications. Explanation of result or special conditions noted:

The DVT is approved based on the confirmation from the Skylink that they do not have

fingerprinting license.

APPROVEFAIL

PRODUCT ASSESMENT (Place Stamp in appropriate result block below)

TEST RESULTNOTE: Irdeto Access Verification covers only CA and loader functionality and does not take

away the operator's responsibility for final approval of all other aspects of the software

functioning in the operator's environment (field trial).

Manufacturer

COSHIP

Driver Version

Not Stated

Model No.

N8760B

DVT EngineerName Date Sign

Sunny Ma 3-Dec-10

58

DVT CERTIFICATION

Report No. Date Tested Operator Software Version

110SkylinkCSHSKLH58101203 12/3/2010

Hardware Version

CSHSKLH58101203.xlsx 6