BS EN 1279:2002
GLASS IN BUILDINGINSULATING GLASS UNITS
DECLARATION OF PERFORMANCETHIS IS TO CERTIFY THAT
of UNIT 10
LITTLE BOYTON HALLBOYTON CROSSCHELMSFORD
ESSEXCM1 4LN
HAVE CONFORMED WITH EN 1279-5 ANNEX ZA
by
(a) SUBMITTING PLAIN INSULATING GLASS UNITS FOR TESTING TO BS EN 1279 PART 2 AND SUCCESSFULLY MEETING ALL REQUIREMENTS.
SUBMITTING PLAIN INSULATING GLASS UNITS FORTESTING TO BS EN 1279 PART 3 AND SUCCESSFULLY
MEETING ALL REQUIREMENTS.
(b) INSTIGATING AND IMPLEMENTING A SYSTEM OF FACTORY PRODUCTION CONTROL COMPLYING WITH BS EN 1279 PART 6
(c) HAVING UNITS TESTED TO THE REQUIREMENTS EN 1279 PART 6 BY CENSOLUTIONS LTD
(d) PRODUCING A TECHNICAL FILE CONTAINING THE TEST REPORT AND PERFORMANCE INDICATION PAPERS FOR ALL COMPONENTS
Signed:.................................................... Date:....................................................
Position:....................................................
Conventional BarPlease refer to Test Report No.TQ-RAP-06-28776
System Description Ref: TGE05ITT conducted by: TNO Quality Services BV
Foamed Spacer Please refer to Test Report No. 7721R-E09.0391-v2
System Description Ref: TGE05ITT conducted by: TNO Quality Services BV
Conventional BarPlease refer to Test Report No.7729R-E09.0391-v2
System Description Ref: TGE05ITT conducted by: TNO Quality Services BV
Foamed Spacer Please refer to Test Report No.7728R-E09.0391-v2
System Description Ref: TGE05ITT conducted by: TNO Quality Services BV
23rd April 2013
Business Development Manager
UNIT 10LITTLE BOYTON HALL
BOYTON CROSSCHELMSFORD
ESSEXCM1 4LN
13
EN 1279-5
Insulated glass units, intended to be used in buildings and construction works.
System: 4mm Clear - 6mm Spacer Air - 4mm Clear (Worst Case Scenario IGU)
Characteristics
Resistance to fire npdReaction to fire A1External fire performance npdBullet resistance npdExplosion resistance npdBurglar resistance npdPendulum body impact resistance npdResistance against sudden temperature changes and temperature differentials
≥ 40+40K
Wind, snow permanent and imposed load resistance
≥ 4+4 mm
Direct airborne sound insulation ≤ 31 (-2; -5) dBThermal properties 3.3W/(m2K)Radiation properties:light transmission and reflection ≥ 0.82/0.15Solar energy characteristics ≥0.73/0.13
Signed:.................................................... Date:....................................................
Position:....................................................
23rd April 2013
Business Development Manager
UNIT 10LITTLE BOYTON HALL
BOYTON CROSSCHELMSFORD
ESSEXCM1 4LN
13
EN 1279-5
Insulated glass units, intended to be used in buildings and construction works.
System: 4mm Clear Toughened - 6mm Spacer Air - 4mm Clear Toughened (Worst Case Scenario Toughened IGU)
Characteristics
Resistance to fire npdReaction to fire A1External fire performance npdBullet resistance npdExplosion resistance npdBurglar resistance npdPendulum body impact resistance ≥1(c)3Resistance against sudden temperature changes and temperature differentials
≥ 200+200
Wind, snow permanent and imposed load resistance
≥ 4+4 mm
Direct airborne sound insulation ≤ 31 (-2; -5) dBThermal properties ≤ 3.3W/(m2K)Radiation properties:light transmission and reflection ≥ 0.82/0.15Solar energy characteristics ≥0.73/0.13
Signed:.................................................... Date:....................................................
Position:....................................................
23rd April 2013