3
Dead Weight Pressure Gauge Te sters are used for calibrating and standardizing pres- sure gauges and pressure transducers upto a pressure of 1000 bar (kg/sq.cm) HEICO Dead Weight Pressure Gauge T es ters are so designed and manufactured that extremely sm all va riations and ve ry small pres su res ca n be measured with grea t ac cura cy i.e. upto + 0.1% or bett er. T he standa rdizing pressure is developed by loading with stan- dardiz ed weights a ve rtically arrange d ram which works in a cylinder filled with oil.. T his cylinder is c onnected to an oil reservoir thro ugh an isola ting valv e. A pr imin g pump, a pressure pump, press ure gauge ad aptor s etc. are als o connecte d to the cy linder.A se t of standar dize d weights, for the testing range of the tester, is supplied wit h ea ch ins trument. A se t of adaptors for different sizes of pressure gauge threads is also provided along with a set of spanners, a needle puller and a screw driver. De ad Weight P ressure Gauge s Tes ters are offered in four models. HL80 Single Ram, Singl e Gauge T ype. HL82 S ingle Ram, T wo Gauge T ype HL84 Double Ram, S ingl e Gauge Ty pe. HL86 Double R am, Two gauge T ype. qq HL80 Single Ram Single Gauge Type S uitable for s tanda rdiz ing one pre ssure gauge against dead weight s. T hes e tes ters have only one pressure range. The appara- tus comprised the following main compo- nents. i) A pre cis ely grou nd a nd la ppe d ra m of known effective area moving without friction in an acc urately hone d cylinde r and provided with a loading platform at its top. ii) A s et of s tanda rdized weigh ts fo r the test range. iii) A priming pu mp-cum-oil reser voir for quic k initial se tting of the unit. iv) A high pres sure s cr ew type pu mp for adjustment during the test at higher pressures. v) An is ola tingvalveforthepr imingpump. vi) Pres su re g auge adap tor. vii) A s et of s pare pressure gau ge ada ptors. viii) Two ope n ended spanners and a nee- dle puller. The appa ra tus is as se mbledon a sturdybas e with lev eli ng s cr ewsan d is en ca s edin a s he et metal cove r. T his type of apparatus is avail- able for the following standard tes t ranges. C at. No. Range (bar) HL 80.05 0.5 - 25 HL80.10 0.5 - 50 HL 80.15 1.0 - 100 HL 80.20 2.0 - 200 HL80.25 2.0 - 300 HL 80.30 5.0 - 500 HL80.35 5.0 - 750 HL80.40 5.0 - 1000 qq HL 82 S ingle R am Two Gauge T yp e These models are very useful for situations warranting f requent checking of pressu re gauge s, when calibration agains t a dea d weight sy stem becomes much time con - suming and cumbersome. Out HL 82 series of testers have the dual arrangements of testing the pressure gauges against stan- dardized weights as well as by comparing the tes t gauge w ith a ca libra ted mas ter gauge, which is very quick and convenient. T he dea d weight loading ramsin t hesemod- els , can be i so late d by an isola ting valv e included in the hydraulic circuit while com - paring the test gauge with a master gauge. HL80 DE AD WE I G HT PR E S S URE GAU GETE S TE R S

Dead Weight Pressure Gauge Testers

Embed Size (px)

Citation preview

Page 1: Dead Weight Pressure Gauge Testers

8/8/2019 Dead Weight Pressure Gauge Testers

http://slidepdf.com/reader/full/dead-weight-pressure-gauge-testers 1/2

Dead Weight Pressure Gauge Testers are

used for calibrating and standardizing pres-sure gauges and pressure transducers upto

a pressure of 1000 bar (kg/sq.cm) HEICO

Dead Weight Pressure Gauge Testers are sodesigned and manufactured that extremelysmall variations and very small pressurescan be measured w ith great accuracy i.e.

upto + 0.1% or bett er. The standardizingpressure is developed by loading with stan-

dardized weights a vertically arranged ramwhich works in a cylinder filled with oil..

This cylinder is connected to an oil reservoirthrough an isolating valve. A primingpump, a pressure pump, pressure gauge

adaptors etc. are also connected to the

cylinder.A set of standardized weights, forthe testing range of the tester, is suppliedwit h each instrument. A set of adaptors for

different sizes of pressure gauge threads isalso provided along with a set of spanners,a needle puller and a screw driver.

Dead Weight Pressure Gauges Testers are

offered in four models.

HL80Single Ram, Single Gauge Type.

HL82Single Ram, Two Gauge Type

HL84

Double Ram, Single Gauge Type.

HL86Double Ram, Two gauge Type.

qq HL80

Single Ram Single Gauge Type

Suitable for standardizing one pressuregauge against dead weight s. These testershave only one pressure range. The appara-

tus comprised the following main compo-nents.

i) A precisely ground and lapped ram ofknown effective area moving without

friction in an accurately honed cylinderand provided with a loading platform

at its top.

ii) A set of standardized weights for the

test range.iii) A priming pump-cum-oil reservoir for

quick initial setting of the unit.iv) A high pressure screw type pump for

adjustment during the test at higherpressures.

v) An isolatingvalveforthe primingpump.

vi) Pressure gauge adaptor.vii) A set of spare pressure gauge adaptors.

viii) Two open ended spanners and a nee-dle puller.

The apparatus is assembledon a sturdybasewith leveling screwsand is encasedin a sheet

metal cover. This type of apparatus is avail-able for the following standard test ranges.

Cat. No. Range (bar)

HL80.05 0.5 - 25

HL80.10 0.5 - 50HL80.15 1.0 - 100

HL80.20 2.0 - 200HL80.25 2.0 - 300

HL80.30 5.0 - 500HL80.35 5.0 - 750

HL80.40 5.0 - 1000

qq HL 82

Single Ram Two Gauge Type

These models are very useful for situations

warranting f requent checking of pressuregauges, when calibration against a deadweight system becomes much time con-

suming and cumbersome. Out HL 82 seriesof testers have the dual arrangements of

testing the pressure gauges against stan-dardized weights as well as by comparing

the test gauge w ith a calibrated mastergauge, which is very quick and convenient.

The dead weight loading ramsin t hese mod-

els, can be isolated by an isolating valveincluded in the hydraulic circuit while com-

paring the test gauge with a master gauge.

HL80

DEADWEIGHTPRESSUREGAUGETESTERS

Page 2: Dead Weight Pressure Gauge Testers

8/8/2019 Dead Weight Pressure Gauge Testers

http://slidepdf.com/reader/full/dead-weight-pressure-gauge-testers 2/2

Supplied complete with a set of weights,spanners, needle puller, pressure gauge

adaptors but without the Master Gauge.Available in the following ranges.

Cat. No. Range(bar)

HL82.05 0.5 - 25HL82.10 0.5 - 50

HL82.15 1.0 - 100

HL82.20 2.0 - 200

HL82.25 2.0 - 300

HL82.30 5.0 - 500

HL82.35 5.0 - 750

HL82.40 5.0 - 1000

qq HL 84

Double Ram Single Gauge Type

Similar HL80 but with two telescopic ramsto give two ranges of pressure with the

same set of weights. Low capacity pressuregauges and high capacity pressure gaugescan be tested with the same precision on

these testers.

Cat No. Low Pressure Range(bar) High Pressure Range(bar)

HL84.30 0.5 - 50 5 - 500

HL84.35 0.5 - 75 5 - 750

HL84.40 0.5 - 100 5 - 1000

Cat No. Low Pressure Range(bar) High Pressure Range(bar)

HL86.30 0.5 - 50 5 - 500

HL86.35 0.5 - 75 5 - 750

HL86.40 0.5 - 100 5 - 1000

HL 84 DOUBLE RAM WITH SINGLE GAUGE ADOPTERS

HL 86 DOUBLE RAM WITH 2 GAUGE ADOPTERS