3ADW000165R0201_Technical_Data_e_b DCS Thyristor Power Converters for DC drive systems 25 to 5200 A Technical Data DCS 400 DCS 500B DCS 600 DCF 500B DCF 600

DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III i

3ADW000165R0201_Technical_Data_e_b

DCS Thyristor Power Convertersfor DC drive systems

25 to 5200 A

Technical Data DCS 400DCS 500BDCS 600DCF 500BDCF 600

Page 2: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III ii

3ADW000165R0201_Technical_Data_e_b

How to use the DCS Documentation System

The matrix below indicates all available product documentation and its corresponding order numbers on its left columns as well as all existingDC Drive systems on its top rows. System descriptions, Technical data and Operating instructions (as far as they are available for thecorresponding drive) are the basic documents and will be delivered together with each drive. All other documentation has to be orderedseparately.

DC drive systems System Drive Standard Drive RebuildCubicle Module Cubicle Module

Product documentation DC

A 6

00

DC

A 6

20

DC

S/D

CF

600

Mul

tiDriv

e

DC

S 6

00 C

rane

Driv

e

DC

A 5

00 /

DC

A 5

20

DC

S 5

00 E

asy

Driv

e

DC

S 4

00 E

asy

Driv

e

DC

S 4

00

DC

S/D

CF

500

B

DC

E 4

00

DC

R

System description Language Volume3ADW000066 EN, DE,FR II D x x x3ADW000072 EN, DE II F x x x3ADW000121 ➀ EN II F1 x x3ADW000095 (Manual) ➁ EN,DE,FR,IT,SP II K x x x3ADW000139 EN II F x x3ADW000071 (Flyer) EN, DE x3ADW000152 EN, DE,FR,IT,SP x3ADW000173 (Flyer) EN x

Technical Data Language Volume3ADW000165 EN III x x x

Operating Instructions Language Volume3ADW000055 EN,DE,FR,SP IV A x x x3ADW000080 EN, DE IV F x x x3ADW000091 (Installation) EN, DE IV F1 x x x x

Software description Language Volume3ADW000078 EN V D1 x x x3ADW000076 EN V F x x x3AST000953 ➂ EN x x

Tools Language Volume3AFE61178775 CMT/DCS500 EN - x x xEN 5926915-1 GAD EN - x x x3ADW000048 (Application blocks) EN V A2 x x x3AFY61296123 Drive Window EN - x x x x

Service Instructions Language Volume3ADW000093 EN, DE VI A x x x x x x x3ADW000131 EN VI K x x x

Fieldbus Language Volume3ADW000086 EN - x x x3ADW000097 EN - x x x x

Others Language Volume3ADW000115 12-Pulse operation EN VIII F2 x x3ADW000092 Rebuild manual EN XI H1 x3ADW000128 Paralleling DCS Conv. EN VIII D1 x x x x3ADW000040 12-Puls operation EN, DE VIII A2 x x

Status: 25.March.2002

➀ Covers information of Technical data➁ Covers information of Technical data, Operating Instructions, Software Description➂ Covers information of Operating Instructions, Software Description

avai

labl

e on

ly fo

r: D

CS

500B

/ 60

0 dr

ive

syst

ems

Page 3: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III iii

3ADW000165R0201_Technical_Data_e_b

Contents

III TECHNICAL DATA1 Quick Guide..................................................................... III 1-1

1.1 DCS 500B (Armature) ............................................................................ III 1-21.2 DCF 500B (Excitation) ........................................................................... III 1-31.3 DCS 600 (Armature) .............................................................................. III 1-41.4 DCF 600 (Excitation) .............................................................................. III 1-51.5 DCS 400 (Armature and Excitation) ....................................................... III 1-6

2 Converter modules ......................................................... III 2-12.1 Dimensions .............................................................................................. III 2-22.2 Fuses - installed inside the converter (Size A5, A6, A7) ....................... III 2-112.3 Cross-sectional areas - Tightening torques ........................................... III 2-122.4 Power losses .......................................................................................... III 2-132.5 Power section cooling ............................................................................ III 2-14

3 Control boards ................................................................ III 3-13.1 SDCS-CON-2 ......................................................................................... III 3-1

4 Power supply board ....................................................... III 4-14.1 SDCS-POW-1 .......................................................................................... III 4-1

5 Power interface boards .................................................. III 5-15.1 Power interface board SDCS-PIN-1x .................................................... III 5-15.2 Power interface board SDCS-PIN-20x/SDCS-PIN-20xB ...................... III 5-25.3 Galvanic isolation - T90, A92 ................................................................. III 5-55.4 Power interface (SDCS-PIN-41 / SDCS-PIN-48 / SDCS-PIN-5x) ......... III 5-95.5 Zero current detection SDCS-CZD-01 ................................................. III 5-135.6 Power signal measuring board SDCS-MP-1 ....................................... III 5-14

6 Digital and analogue I/O boards .................................... III 6-16.1 Digital I/O board SDCS-IOB-2 ............................................................... III 6-26.2 Analogue I/O board SDCS-IOB-3 .......................................................... III 6-46.3 Extension bord SDCS-IOE-1 ................................................................. III 6-8

7 Communication boards .................................................. III 7-17.1 Communication board SDCS-COM-5 .................................................... III 7-17.2 Control and communication board SDCS-AMC-DC .............................. III 7-27.3 DDCS Branchning unit NDBU-95 .......................................................... III 7-6

8 Field exciters .................................................................. III 8-18.1 SDCS-FEX-1 (internal) ........................................................................... III 8-18.2 SDCS-FEX-2 / SDCS-FEX-2 (internal) .................................................. III 8-28.3 DCF503A-0050 and DCF504A-0050 (external) .................................... III 8-48.4 DCF505 / DCF506 Overvoltage protection ............................................ III 8-9

9 Accesories ...................................................................... III 9-19.1 Accessories - Power circuit .................................................................... III 9-19.2 Accessories - Field ................................................................................. III 9-69.3 Fan, electronics ...................................................................................... III 9-79.4 Residual current detection ..................................................................... III 9-89.5 EMC Filters ........................................................................................... III 9-10

Appendix A ..........................................................................III A-1Optical cables ................................................................................................ III A-1

We recommend to use both, SYSTEMDESCRIPTION plus TECHNICAL DATA at thesame time in case you are planningand engineering your drive.

You will find all necessary technicalinformation in there to solve yourproblem.

Page 4: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III iv

3ADW000165R0201_Technical_Data_e_b

Page 5: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 1-1

3ADW000165R0201_Technical_Data_e_b

1 Quick GuideGeneral remarksThe term “DCS thyristor power converter” is a general designation for basic DC converters from ABB. This termcan be found in many parts of the relevant documentation. The precise product name in accordance with thebrief descriptions given below characterizes a specific unit.

Brief description of DCS 500BThe DCS 500B unit range is an enhancement developed from the DCS 500 range.The DCS 500B is an armature converter with the following standard features:• Design and commissioning tools • Monitoring functions • Communication via databus • Human-machineinterface • More than 300 additional functions blocks programmable under Win-dows • Graphical Application Designer • Plain text display • FOR HIGH POWER

Brief description of DCF 500BWith software release 21.232 or higher DCS 500B has a '3-phase field exciter mode'. A DCF 500B is a three-phase field exciter based on the programmable DCS 500B software and the SDCS-CON-2 control board.The interface board PIN-1x is modified; - an overvoltage protection unit DCF 505/506 is required.

Brief description of DCS 600The DCS 600 converter family is based on the hardware developed for the DCS 500B type.Instead of a COM-x board, the SDCS_AMC_DC board is used. PC tools will be connected there, as well asthe APC (Application controller), if the APC is used as a PLC. If a different PLC is used, separate adaptermodules are needed. They must be connected to the AMC-DC board, too. The software code always beginswith S15.xxx for MultiDrive or S18.xxx for Crane drives.

Brief description of DCF 600The DCF 600 unit range is intended to be used for supplying motor fields and is based on the hardware andsystem configuration of the DCS 600 unit. The software is identical to the DCS 600 software. Similar to DCF500B units the DCF 505/506 overvoltage protection unit is required. The same modification is applied to thePIN-1x board, compared to DCF 500B.

Brief description of DCS 400The DCS 400 is the smallest drive in its class. The compact design has been partly achieved by a fully integratedfield exciter based on IGBT technology. A commissioning wizard - available on the control panel and the PCtool - makes start-up of the drive easy. In addition, the DCS 400 contains application macros.

Page 6: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 1-2

3ADW000165R0201_Technical_Data_e_b

1.1 DCS 500B (Armature)

This functional overview of DCS 500B componentsmakes it easy to find detailed technical data in thecorresponding chapters.

L1K1

T2

Q1

F2

F3

X12:

X13:

X37:

X1:

X2:

M

T

T

83

85

72

X17:

X16:

X14:

PC +

CM

T/D

CS5

00

DCF 503A / 504A

CO

M 5

CO

N 2

POW

1

PIN

1x

PIN

51

DCF 501B / 502B

IOB

2x

IOB

3IO

E 1

PS53

11

X11:

X33:

PIN

20x

7 3

8 4

T3

F1

K5

K3

≤ 69

0V

≤ 10

00V

CD

P 31

2

SNA

T 6x

x

FEX

1FE

X 2

µPM

DC

S 50

.B...

.-.1-

21...

..

PIN

41

PIN

41

L3*

+24

V

dcsb_sys_g.dsf

CO

M x

- sh

ort d

esig

natio

n of

com

pone

nts

anal

ogue

inpu

t / o

utpu

tal

tern

ativ

e

EMC

filte

r

Eart

h-fa

ult m

onito

r

Fiel

d bu

s to

the

PLC

optical fibre optical fibre

digi

tal i

nput

/ ou

tput

Lege

nd

7.1

- det

aile

d de

scrip

tion

see

chap

ter 7

.1se

e T

ech

nic

al D

ata

*

to fi

eld

Pow

ersu

pply Three-phase field supply

Fiel

d B

usA

dapt

erM

odul

eN

xxx

7.1

3.1

4.1

5.1

5.4

6.1

6.2

6.3

6.2

5.2

9.1

9.3

9.2

8.1

8.2

2

8.3

8.4

5.4

5.4

2

Page 7: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 1-3

3ADW000165R0201_Technical_Data_e_b

1.2 DCF 500B (Excitation)

This functional overview of DCF 500B componentsmakes it easy to find detailed technical data in thecorresponding chapters.

X1:

X2:

X17:

X16:

CO

M 5

CO

N 2

X11:

X33:

CD

P 31

2

µP

83

85

72

IOB

2x

IOB

3IO

E 1

PS53

11

7 3

8 4

+24

V

L1K3

T2

Q1

F2

X37:

PC +

DD

C-T

ool

POW

1

PIN

1x

DCF 506

PIN

20x

F1

K5

≤ 69

0V

≤ 50

0V

SNA

T 6x

x

M

DC

F 50

.B...

.-.1-

21...

..

X12:

X13:

CZD-0x

dcf5b_sys_f.dsf

CO

N x

- sh

ort d

esig

natio

n of

com

pone

nts

anal

ogue

inpu

t / o

utpu

tal

tern

ativ

e

EMC

filte

r

Eart

h-fa

ult m

onito

r digi

tal i

nput

/ ou

tput

Lege

nd

7.1

- det

aile

d de

scrip

tion

see

chap

ter 7

.1

mod

ified

optical fibre optical fibre

Fiel

d bu

s to

the

PLC

to X

16: D

CS

500

B

(Arm

atur

e co

nver

ter)

to a

dig

ital i

nput

of D

CF

500

B

Fiel

d B

usA

dapt

erM

odul

eN

xxx

7.1

3.1

4.1

5.1

6.1

6.2 6.

2

5.2

9.1

9.3

22

8.4

6.3

5.6

Page 8: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 1-4

3ADW000165R0201_Technical_Data_e_b

1.3 DCS 600 (Armature)

This functional overview of DCS 600 componentsmakes it easy to find detailed technical data in thecorresponding chapters.

DCF 601 / 602

X1X2

X17

AM

C-D

C

X11

X33

DSP

V260

CH

3

CH

0

CH

2

CO

N 2 µP X1

6

7 3

8 4

X14

72IO

E 1

Mo

nito

rin

gL

ED

bar

NLM

D

Pane

lC

DP

312

L1K1

T2

Q1

F2

F3

M

T

T

83

85

PC +

Driv

eWin

dow

DCF 503A / 504A

POW

1

PIN

1x

PIN

51

IOB

2x

IOB

3

PS53

11PIN

20x

B

T3

F1

K5

K3

≤ 69

0V

≤ 10

00V

-ND

PA-0

2-N

DPC

-12

-NIS

A-0

3 (I

SA

)

FEX

1FE

X 2

M

PIN

41

PIN

41

L3N

DB

U95

(PC

MC

IA)

X12

X13

X37

Mul

tiDriv

eso

cket

ND

PI

A92

T90

DC

S 6.

.-....

-.1-1

5....

. (..

.. -.1

-18.

....)

dcs6_sys_h.dsf

X10 X1

6(2

4V)

X37

X12

X13

X12

X13

X12

X13

X2

X3

X4,5

X6X4

X3X3

X5X2

X1

X2X1

7

X1

U1

V1

W1

C1

D1

X1X1

X1X1

X14

X14

U1

V1

U1

V1

W1

C1

D1

C1

D1

X16

X2

X99

X1

X1

X3

X3X2

CO

N x

- sh

ort d

esig

natio

n of

com

pone

nts

anal

ogue

inpu

t / o

utpu

tal

tern

ativ

e

EMC

filte

r

Eart

h-fa

ult m

onito

r

to th

e PL

Cop

tical

fibr

edi

gita

l inp

ut /

outp

ut

Lege

nd

7.1

- det

aile

d de

scrip

tion

see

chap

ter 7

.1

PLC

-Adv

ant

con

trol

- Mas

ter/

Fol

low

erFi

eld

Bus

Ada

pter

Mod

ule

Nxx

x

to other drives

Rev

D o

r lat

er

12-P

ulse

link

Pow

ersu

pply Three-phase field supply

* co

nnec

tion

see

Tech

nica

l dat

a c

hapt

er 5

*

7.2

3.1

4.1

5.1

5.4

6.1

6.2

6.2

5.3

5.2

9.1

9.3

9.2

8.1

8.2

2

8.3

5.4

5.4

7.3

6.3

2

8.4

Page 9: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 1-5

3ADW000165R0201_Technical_Data_e_b

1.4 DCF 600 (Excitation)

This functional overview of DCF 600 componentsmakes it easy to find detailed technical data in thecorresponding chapters.

AM

C-D

C

DSP

CH

3

CH

0

CH

2

CO

N 2

µ P

Mon

itori

ng

LED

bar

NLM

D

Pane

lC

DP

312

Mul

tiDriv

eso

cket

ND

PI

L1K3

T2

Q1

F2

M

83

85

PC +

Driv

eWin

dow

DCS 600

POW

1

PIN

1x

DCF 506

IOB

2x

IOB

3

F1

K5

≤ 69

0V

500V

M

DC

F 6.

.-....

-.1-1

5....

.

ND

BU

95

-ND

PA-0

2-N

DPC

-12

-NIS

A-0

3 (I

SA

)

(PC

MC

IA)

72IO

E 1

7 3

8 4

CZD-0x

PIN

20x

B

V260

X16

(24V

)X1

X2X1

7

X11

X33

X16

X14

X12

X13X3

7

dcf6_sys_i.dsf

X10

X37

X12

X13

X12

X13

X1 X3

X4,5

X6X4

X3X2

X1

X2X1

7

X1

U1

V1

W1

C1

D1

C1

D1

X11

X12

X16

X4

X99

X3

X3X2

CO

N 2

- sh

ort d

esig

natio

n of

com

pone

nts

anal

ogue

inpu

t / o

utpu

tal

tern

ativ

e

EMC

filte

r

Eart

h-fa

ult m

onito

r

to th

e PL

Cop

tical

fibr

edi

gita

l inp

ut /

outp

ut

Lege

nd

7.1

- det

aile

d de

scrip

tion

see

chap

ter 7

.1

PLC

-Adv

ant

con

trol

- Mas

ter/

Fol

low

erFi

eld

Bus

Ada

pter

Mod

ule

Nxx

x

to other drives

mod

ified

Rev

D o

r lat

er

to a

dig

ital i

nput

of D

CF

600

7.2

3.1

4.1

5.1

6.1

6.25.2

9.1

9.3

2

8.4

7.3

6.3

5.6

2

Page 10: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 1-6

3ADW000165R0201_Technical_Data_e_b

1.5 DCS 400 (Armature and Excitation)

Remark:All detailed information about the DCS 400 DC drive you can only find in the DCS 400Manual (documentation no. 3ADW 000 095).

L1K1

Q1

M

T

T

SDC

S-C

ON

-3A

42

F1

230.

..500

V

µPM

DC

S 40

0

115.

..230

V A

C11

5 / 2

30 V

AC

82

1

RS232

SDC

S-PI

N-3

A

dcs4_sys_c.dsf

EMC

filte

r

Fiel

d bu

s to

the

PLC

Lege

nd

Pow

erSu

pply

Thyr

isto

rco

ntro

l

PC +

Tool

or

PLC

Con

trol

ele

ctro

nics

Field supplySDCS-FIS-3A

Inpu

ts /

Out

puts

Serialinterfaces

optical fibre

digi

tal i

n- /o

utpu

t, 24

V; n

o ga

lvan

ic is

olat

ion

Ana

logu

e ou

tput

; 11

bit +

sign

anal

ogue

inpu

t; 11

bit

+sig

nR

elay

out

put;

250

V A

C, 3

A

Fiel

dco

ntro

l

Con

trol

pan

elD

CS4

00PA

N

Fiel

d B

usA

dapt

erM

odul

eN

xxx

Page 11: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-1

3ADW000165R0201_Technical_Data_e_b

2 Converter modules

M

L1 L2 L3

F1x

F1x

F1x

F1x

F1x

F1x

DCS 500 / DCS 500B / DCS 600 / DCF 500B / DCF 600Unit range type DCF 500B and DCF 600 for output current of up to max. 520 A available2.1 Dimensions ............................................................................................ III 2-22.2 Fuses - installed inside the converter (Size A5, C4) ............................ III 2-122.3 Cross-sectional areas - Tightening torques ......................................... III 2-142.4 Power losses ........................................................................................ III 2-162.5 Power section cooling .......................................................................... III 2-19

Note:For clearness the type designationin this chapter is shown in the fol-lowing way:

Designation is valid for

DCS 500 DCS 500BDCS 600DCF 500BDCF 600

Page 12: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-2

3ADW000165R0201_Technical_Data_e_b

2.1 Dimensions

Module C1DCS 50x-0025DCS 50x-0050DCS 50x-0075

Dimensions in mmWeight appr. 7.6 kg

Module C1DCS 50x-0100DCS 50x-0110DCS 50x-0140

Dimensions in mmWeight appr. 11.5 kg

Fig. 2.1/1: Dimension drawing C1-Module

Fig. 2.1/2: Dimension drawing C1-Module

(+) (-)

250

Center of hinge

Swinging radius

(+) (-)

Swinging radius

Center of hinge

DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600

Page 13: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-3

3ADW000165R0201_Technical_Data_e_b

Module C2DCS 50x-0200DCS 50x-0250DCS 50x-0270DCS 50x-0350

Dimensions in mmWeight appr. 22,8 kg

Module C2DCS 50x-0450DCS 50x-0520

Dimensions in mmWeight appr. 29 kg

Busbars in mm: 25 x 3

Busbars in mm: 30 x 5

Fig. 2.1/3: Dimension drawing C2-Module

Fig. 2.1/4: Dimension drawing C2-Module

DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600

(+) (-)

150

250

176 (0200/0250)191 (0270/0350)

Swinging radius

Center of hinge

(+) (-)

150

250

Swinging radius

Center of hinge

Page 14: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-4

3ADW000165R0201_Technical_Data_e_b

150

250

Swinging radius

Center of hinge

10

M1266 50

C1 D1

V1U1 W1

Heat sink

press-in nut

C2_680_b.dsf

Module C2DCS 50x-0680DCS 50x-0820DCS 50x-1000

Dimensions in mmWeight appr. 42 kg

DCS 500 valid for DCS 500B / DCS 600

Fig. 2.1/5: Dimension drawing C2-Module

Main Connectionsat view from top

Busbars in mm:AC and DC 40 x 5

265200

150

C2b_terminal_cover.dsf

Terminal cover

The plastic protection cover forC2b serves as a protection againstelectric shock for the five high-powerterminals at the lower end of the con-verter. It is equipped with a hole oneach side, which will snap-in duringmounting at a press-in nut at eachside panel of the converter.

Page 15: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-5

3ADW000165R0201_Technical_Data_e_b

Module A5DCS 50x-0903DCS 50x-1203DCS 50x-1503DCS 50x-2003

Dimensions in mmWeight appr. 110 kg

Fig. 2.1/6: Dimension drawing A5-Module

Busbars in mm:DC 80 x 10AC 60 x 5

DCS 500 valid for DCS 500B / DCS 600

* 3 drill holes to fix the CDP312 panel on the cover; panel tobe connected electrically via panel extension cable (3 m)

*

Mounting the converter module A5 inside an enclosureTwo supports should be mounted inside the enclosure in such a way, that theycan carry the converter's weight when placing the converter later on. The mini-mum distance between the supports should not be less then 480 mm becauseof electrical clearance (DC busbars).

A L-shape support as indicated will allow to place the converter temporarilyclose to the front end of the support (weight still taken by a lifting device) andthen push it back to the back plate of the enclosure. The upper and lower holesin the back plate of the converter should be used to fix the converter in that po-sition.

510

450

127.5 125 125

U1 V1 W1

55

276

400

461483

102

earthing M12

C1 D1

325.5

65.5 25 50 50 50

Ø 14

17.75

44.5

8069

773

400

85.517 26

for M10

22

Ø 14

1726

34

1005 820

775

250

Min

imu

m T

op c

lear

ance

A5_dim_a.dsf

Support Support

min. 480> 510

earthingM12

100

Min

imu

mB

otto

m c

lea

ranc

e

cable traywith = 40 mmheight =39 mm

fan terminals

fan terminals

Page 16: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-6

3ADW000165R0201_Technical_Data_e_b

Module A6DCS 50x-1903DCS 50x-2053DCS 50x-2503DCS 50x-3003

Dimensions in mmWeight appr. 180 kg

Fig. 2.1/7: Dimension drawing A6-Module (as delivery state)

DCS 500 valid for DCS 500B / DCS 600

468.2

136

C

D

U

V

W

A6_dim.dsf

M12

409

225

200

1750

200

200

62

M1072 100

759.

5

40

50

355

from the front, right,left and back

Pressure switch

63

458.2

10x2020

1725

C

D

U

V

W

385

445

10x2

010

79.5

15

425375

250

Air entry

Air outlet

* 3 drill holes to fix the CDP312 panel on the cover; panel tobe connected electrically via panel extension cable (3 m)

*

Page 17: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-7

3ADW000165R0201_Technical_Data_e_b

DCS 500 valid for DCS 500B / DCS 600

Mounting the converter module A6 inside an enclosureThe converter is designed to be placed on a bottom plate or similar and then fixed on top to the enclosure's back plate to avoid movementsto the front, right or left side. In addition to that the converter should be fixed at the bottom using two brackets in front of the elongated holes.

Cooling air entryThe cooling fan takes the air from the backside, bothsides and from the area underneath the convertermodule.

Cooling air outletTo avoid circulating air inside the enclosure it isrecommended to make sure the exhaust air leavesthe enclosure.

100

72.2

21.8

0

0 25 75 125

175

272

312

352

372

25

75Ø14

250

140

A6_cable_term_busb.dsf

Power cable connectionThe power cable connection is performed via Termi-nal option 01 for A6. This option consists of five rightangle copper busbars and five times four screws. Themechanical details are shown by the figure below.

When mounting the right angle busbars or connectingcables directly please make sure the right screws areused. The converter module is equipped with a blindhole and a nut at its end. Because of that the length ofthe remaining threads is limited to 35 mm (see draw-ing below).

50

50

50

~ 100

~ 1

00

Free space around the converter moduleoptimum compromise

Top view Top view

Fig. 2.1/8: Cooling air flow

Fig. 2.1/11: Free space

Fig. 2.1/9: Right angle copper busbar

Fig. 2.1/10: Length of remaining threads

Fig. 2.1/13: Example right side connection

468.2

136

Fig. 2.1/12 gives an example, how the right anglebusbars can be mounted in case all cable connec-tions are still made at the left side of the convertermodule. This results in four layers for the powercables.

In case the AC or DC connection or perhaps both ofthem have to be made at the right side of the convertermodule use the space behind the converter and movethe power terminals via a right angle busbar up to thatpoint where the final connection is most suitable. Inthis case the busbars need to be fixed at the cubicle/ enclosure, not at the converter module! Fig. 2.1/13gives a rough example, how a right side connectioncan be made

Fig. 2.1/12: Right angle busbar connectionFig. 2.1/14: Cable entries

Cable entries

View from: the right side the back the left side(power connections

air flow

air flow air flow

air flow

air flowair flow

A6_li_air_inlet.dsf

C

D

U

V

Wdo

not

uns

crew

this

scr

ews

!

elec

tron

ics

pow

er s

uppl

yco

ntro

l cab

les

pres

sure

switc

hco

nver

ter f

an(le

ft an

d rig

ht s

ide)

A6_li_air_inlet.dsf

max.35mm

Page 18: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-8

3ADW000165R0201_Technical_Data_e_b

Module A7DCS 50x-2053 xxxLDCS 50x-2603 xxxLDCS 50x-3303 xxxLDCS 50x-4003 xxxLDCS 50x-4803 xxxLDCS 50x-5203 xxxL

Dimensions in mmWeight appr. 315 kg

Fig. 2.1/15: Dimension drawing A7-Module (left-hand connection)

DCS 500 valid for DCS 500B / DCS 600

Busbars in mm:AC and DC 100 x 10

8080

8080

93

230 530

350 for M10

200

225

200

200

1725

A7_dim_a.dsf

759

.5

25

for M10

Pressure switch

* 3 drill holes to fix the CDP312 panel on the cover; panel tobe connected electrically via panel extension cable (3 m)

*

Page 19: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-9

3ADW000165R0201_Technical_Data_e_b

Fig. 2.1/16: Dimension drawing A7-Module (right-hand connection)

DCS 500 valid for DCS 500B / DCS 600

Module A7DCS 50x-2053 xxxRDCS 50x-2603 xxxRDCS 50x-3303 xxxRDCS 50x-4003 xxxRDCS 50x-4803 xxxRDCS 50x-5203 xxxR

Dimensions in mmWeight appr. 315 kg

Busbars in mm:AC and DC 100 x 10

A7_dim_a.dsf

200

225

200

200

172

5

759

.5

25

for M10

for M10

Pressure switch

* 3 drill holes to fix the CDP312 panel on the cover; panel tobe connected electrically via panel extension cable (3 m)

*

Page 20: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-10

3ADW000165R0201_Technical_Data_e_b

DCS 500 valid for DCS 500B / DCS 600

Mounting the converter module A7 inside an enclosureThis type of converter module uses the same fixing principles as described for converter module A6!

Cooling air entryThe cooling fan takes the air from the backside, leftand right side and from the area underneath theconverter module.

Cooling air outletTo avoid circulating air inside the enclosure it isrecommended to make sure the exhaust air leavesthe enclosure.

Free space around the converter moduleDo not place the converter module in a corner. In casethe fan cannot take the air through the bottom plate ofthe enclosure non of the remaining entries has to beblocked.

Air entry through bottom plateMake sure the converter module gets clean air, be-cause there is no air filter in front of the fan at theconverter.

Fig. 2.1/17: Cooling air flow

Fig. 2.1/18: Free space

View from front left side / (right side)

View from bottom

air flo

wai

r flo

w

air f

low

Cable entriesThe cable entries are existing symmetrically on bothsides. Nevertheless only the entries on the left sideshould be used for cables going to the electronicspower supply (SDCS-POW-1) or the controller board(SDCS-CON-x).

Fig. 2.1/19: Cable entries

50

>20

Top view

elec

tron

ics

pow

er s

uppl

yco

ntro

l cab

les

pres

sure

switc

h

conv

erte

r fan

A7_re_air_inlet.dsf

for right type con-verter equivalent

Page 21: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-11

3ADW000165R0201_Technical_Data_e_b

Converter type Model Fuse F1 Size Type400 V / 500 VDCS 50x-1203-41/51 A5 800A 660V UR 5 170M 6162DCS 50x-1503-41/51 A5 1250A 660V UR 5 170M 6166DCS 50x-2003-41/51 A5 1600A 660V UR 5 170M 6169DCS 50x-2053-51 A6 1500A 660V UR 5 170M 6168DCS 50x-2503-41/51 A6 900A 660V UR ➀ 5 170M 6163DCS 501-3003-41/51 A6 1500A 660V UR ➀ 5 170M 6168DCS 502-3003-41/51 A6 1250A 660V UR ➀ 5 170M 6166DCS 50x-3303-41/51 A7 2500A 660V UR 7 170M 7026DCS 50x-4003-41/51 A7 3000A 660V UR 7 170M 7028DCS 50x-5203-41/51 A7 3500A 660V UR 7 170M 7057600 V / 690 VDCS 50x-0903-61/71 A5 630A 1250V UR 6 170M 6144DCS 50x-1503-61/71 A5 1100A 1250V UR 6 170M 6149DCS 501-2003-61/71 A5 1400A 1100V UR 6 170M 6151DCS 50x-2053-61/71 A6 700A 1250V UR ➀ 6 170M 6145DCS 50x-2503-61/71 A6 1000A 1250V UR ➀ 6 170M 6148DCS 501-3003-61/71 A6 1100A 1250V UR ➀ 6 170M 6149DCS 502-3003-61/71 A6 1000A 1250V UR ➀ 6 170M 6148DCS 50x-3303-61/71 A7 2500A 1000V UR 8 170M 7036DCS 50x-4003-61/71 A7 3000A 1000V UR 8 170M 7156DCS 50x-4803-61/71 A7 3000A 1000V UR 8 170M 7156790 VDCS 50x-1903-81 A6 700A 1250V UR ➀ 6 170M 6145DCS 50x-2053-81 A6 700A 1250V UR ➀ 6 170M 6145DCS 50x-2503-81 A6 1000A 1250V UR ➀ 6 170M 6148DCS 501-3003-81 A6 1100A 1250V UR ➀ 6 170M 6149DCS 502-3003-81 A6 1000A 1250V UR ➀ 6 170M 6148DCS 50x-3303-81 A7 2500A 1000V UR 8 170M 7036DCS 50x-4003-81 A7 3000A 1000V UR 8 170M 7156DCS 50x-4803-81 A7 3000A 1000V UR 8 170M 71561000 VDCS 50x-2053-91 A7 1800A 1250V UR 9 170M 7976DCS 50x-2603-91 A7 1800A 1250V UR 9 170M 7976DCS 50x-3303-91 A7 2500A 1250V UR 9 170M 7978DCS 50x-4003-91 A7 2500A 1250V UR 9 170M 7978

➀ 12 fuses per bridge (2x per F1x)Table 2.2/1: Fuses installed inside the converter

2.2 Fuses - installed inside the converter

Size 5, 6

Size a b c d5 50 29 30 766 80 14 30 76

Size A7 628 909 10510 120

Size 7...10

Remark:Given dimensions may be exceeded insome cases. Please take them only forinformation.

15

4xM10min 10 deep

Ø 3

3

2525

100

67.5

82.5

Ø 11

max 105

Ø 5

6

A8

max

105m

ax d

max d108

c11

11

14 17

139

6

b a b

Indicator

Fig. 2.2/1: Fuses size 5, 6

Fig. 2.2/2: Fuses size 7...10

L1 L2 L3

F1x

F1x

F1x

F1x

F1x

F1x

DCS 500 valid for DCS 500B / DCS 600

Page 22: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-12

3ADW000165R0201_Technical_Data_e_b

You will find instructions on how to calculate the PEconductor’s cross-sectional area in VDE 0100 or inequivalent national standards. We would remind youthat power converters may have a current-limitingeffect.

2.3 Cross-sectional areas - Tightening torques

➀ Reduced ambient temperature 40°C

➁ Option for more flexible cable connection available

Table 2.3/1: Cross-sectional areas - tightening torques

Recommended cross-sectional area to DINVDE 0276-1000 and DINVDE 0100-540 (PE) trefoil arrangement, up to 50°C ambienttemperature.

DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600

epytretrevnoC )1MK,1MA(1D,1C )5KA,3KA,1KA(1W,1V,1U EP

]mN[

CDI]-A[

.1

]²mm[

).2(

]²mm[vI

]~A[

.1

]²mm[

).2(

]²mm[ ]²mm[

xx-5200-x05SCD 52 4x1 - 02 4x1 - 4x1 6Mx1 6

xx-0500-x05SCD 05 01x1 - 14 6x1 - 6x1 6Mx1 6

xx-5700-x05SCD 57 52x1 - 16 52x1 - 61x1 6Mx1 6

xx-0010-x05SCD 001 52x1 - 28 52x1 - 61x1 6Mx1 6

xx-0110-x05SCD 011 52x1 - 09 52x1 - 61x1 6Mx1 6

xx-0410-x05SCD 041 53x1 - 411 53x1 - 61x1 6Mx1 6

xx-0020-x05SCD 002 53x2 59x1 361 52x2 59x1 52x1 8Mx1 31

xx-0520-x05SCD 052 53x2 59x1 402 52x2 59x1 52x1 8Mx1 31

xx-0720-x05SCD 072 53x2 59x1 022 52x2 59x1 52x1 8Mx1 31

xx-0530-x05SCD 053 07x2 - 682 05x2 05x1 8Mx1 31

xx-0540-x05SCD 054 59x2 - 763 59x2 - 05x1 01Mx1 52

xx-0250-x05SCD 025 59x2 - 424 59x2 - 05x1 01Mx1 52

xx-0860-x05SCD 086 021x2 - 555 021x2 - 021x1 21Mx1 05

xx-0280-x05SCD 028 051x2 - 966 021x2 - 021x1 21Mx1 05

xx-3090-x05SCD 009 59x4 051x3 437 07x4 59x3 051x1 21Mx2 05

xx-0001-x05SCD 0001 581x2 - 618 051x2 - 051x1 21Mx1 05

xx-3021-x05SCD 0021 021x4 - 979 59x4 021x3 581x1 21Mx2 05

xx-3051-x05SCD 0051 581x4 - 4221 051x4 - 051x2 21Mx2 05

xx-3002-x05SCD 0002 021x8 581x6 2361 042x4 - 042x2 21Mx2 05

xx-3091-x05SCD ➁ 0091 021x8 581x6 0551 042x4 021x3 21Mx4 05

xx-3502-x05SCD ➁ 0502 021x8 581x6 3761 021x6 051x5 021x3 21Mx4 05

xx-3052-x05SCD ➁ 0052 581x7 - 0402 021x8 581x6 021x4 21Mx4 05

xx-3062-x05SCD 0062 581x7 - 2212 021x8 581x6 021x4 21Mx4 05

xx-3003-x05SCD ➁ 0003 581x8 - 8442 581x7 - 051x4 21Mx4 05

xx-3033-x05SCD 0033 581x8 - 3962 581x7 - 051x4 21Mx4 05

xx-3004-x05SCD 0004 003x7 - 4623 042x8 - 042x4 21Mx4 05

xx-3084-x05SCD ➀ 0084 003x8 - 6783 003x6 - 003x3 21Mx4 05

xx-3025-x05SCD ➀ 0025 003x8 - 2024 003x6 - 003x3 21Mx4 05

Page 23: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-13

3ADW000165R0201_Technical_Data_e_b

2.4 Power losses

The units’ power loss is made up of several differentcomponents:• current-dependent losses PV-I

- of the thyristors- of the fuses- of the busbar system

• voltage-dependent losses PV-U

- snubber circuit of the thyristors (worst case)- thyristors at di/dt < 20 A/µs

• almost constant losses PV-C

- unit electronics- unit fan- field supply

Depending on what you want to achieve by yourpower-loss study, you must make up your mind on thefollowing points:

• Efficiency calculation for the drive system con-cerned:

For this purpose, all the power-loss compo-nents mentioned above (and additionally thelosses caused, for instance, by the motor fan,line reactor, cabling of network/power convert-er/motor, field supply unit and matching trans-former, etc.) must be added.

• Fan losses can be estimated by 95% of the fanpower consumption (see table 2.5/2).

Remarks on the table• The values stated are “worst case”, i.e. the values

obtained under the most unfavourable conditions.• The losses of the unit electronics can be assumed

to be PV-C = 30 ... 60 W, dependent on the loadinginvolved (SDCS-COMx, number of binary inputs to“1-signal”, pulse encoder used, etc.).

• The current-dependent losses can be convertedas follows for the partial load range:

2

%100%*6.0*

%100%*4.0* ⎟

⎠⎞

⎜⎝⎛+≈ −−−xPxPP IVIVpartIV

• For the units ≤ 1000 A, the losses due to externalsemiconductor busbars, busbar systems/wiringare not included.

DCS 500

DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600

Converter type y → y=4 (400 V) y=5 (500 V) y=6 (600 V) y=7 (690 V) y=8 (790 V) y=9 (1000V)

x=1 → 2-Q I

DC [A] [W] [W] [W] [W] [W] [W]

x=2 → 4-Q 4Q 2Q PV-I

PV-U

PV-I

PV-U

PV-I

PV-U

PV-I

PV-U

PV-I

PV-U

PV-I

PV-U

DCS50x-0025-y1 25 25 60 30 60 47DCS50x-0050-y1 50 50 123 30 123 47DCS50x-0050-61 50 50 108 46DCS50x-0075-y1 75 75 175 30 175 47DCS50x-0100-y1 100 100 207 50 207 70DCS50x-0110-61 110 100 284 100DCS50x-0140-y1 140 125 311 50 311 70

DCS50x-0200-y1 200 180 488 50 488 70DCS50x-0250-y1 250 225 656 50 656 70DCS50x-0270-61 270 245 781 100DCS50x-0350-y1 350 315 840 50 840 70DCS50x-0450-y1 450 405 1040 70 1040 80 1119 110DCS50x-0520-y1 520 470 1238 70 1238 80DCS50x-0680-y1 680 610 1622 105 1622 140DCS50x-0820-y1 820 740 1986 125 1986 160DCS50x-1000-y1 1000 900 2527 125 2527 160

DCS50x-0903-y1 900 900 4190 930 4190 1170DCS50x-1203-y1 1200 1200 4510 420 4510 600DCS50x-1503-y1 1500 1500 4740 460 4740 640 5540 850 5540 1080DCS50x-2003-y1 2000 2000 5950 470 5950 660 6820 1100 6820 1370

DCS50x-1903-81 1900 1900 7150 1800DCS50x-2053-y1 2050 2050 7160 880 8050 1140 8050 1410 7300 1820DCS501-2503-y1 2500 8250 590 8250 800 8930 1220 8930 1510 8930 1830DCS502-2503-y1 2500 8400 900 7820 1200 8400 1510 8400 1850 8400 2210DCS501-3003-y1 3000 9570 450 9750 620 9430 1410 9430 1740 9430 2090DCS502-3003-y1 3000 9900 900 9900 1200 10300 1510 10300 1850 10300 2210

DCS50x-2053-91 2050 2050 7090 2630DCS50x-2603-91 2600 2600 9420 2690DCS50x-3303-y1 3300 3300 10850 570 10850 780 11700 1190 11700 1470 11700 1780 11600 4650DCS50x-4003-y1 4000 4000 12300 480 12300 660 13350 1520 13350 1860 13350 2230 15400 4800DCS50x-4803-y1 4800 4800 16800 2300 16800 2750 16800 3250DCS50x-5203-y1 5200 5200 17250 1390 17250 1800

Table 2.4/1: DCS 500 Power losses

Page 24: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-14

3ADW000165R0201_Technical_Data_e_b

2.5 Power section cooling

Fan assignment for DCS 500

Fan data for DCS 500

Fan connection for DCS 500

Table 2.5/2: Fan data for DCS 500

Table 2.5/1: Fan assignment for DCS 500

DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600

Config. 1

M~

1 2 3X2:

Config. 2

M~ϑ

1 2 3 4 5X2:

Config. 3

M~ϑ

1 2 3 4 5X2:

Config. 4 Config. 5

epytretrevnoC ledoM noitarugifnoC epytnaF

...1y-5200-x05SCD1y-5700-x05SCD

1C 1 2B25NC

...1y-0010-x05SCD1y-0410-x05SCD

1C 2 341E2W

...1y-0020-x05SCDy-0280-x05SCD

2C 3 002E2W

1y-0001-x05SCD 2C 3 052E2W

...1y-3090-x05SCD1y-3002-x05SCD

5A 4 061E2D

...8/5/4y-3091-x05SCD8/5/4y-3003-x05SCD

6A 5M13RG

V005...004

...7/6y-3091-x05SCD7/6y-3003-x05SCD

6A 5M13RG

V096...005

...1y-3033-x05SCD1y-3025-x05SCD

7A 5C53RG

V096/V004

Terminals on top of converter housing

Converter housing

M~ϑ

2 31 5 6X2: 4

TW TWL N

Fan_con_c.dsf

blue

blac

k

brow

nw

hite

whi

te

gree

n/y

ello

w

gray

gray

Fan

CN 52 B2

W2E 143

W2E 200 W2E 250 D2E 160 GR31M 380... 500 V

GR31M 525... 690 V

GR35C 400 / 690 V

Rated voltage [V] 208...230; 1~ 230; 1~ 230; 1~ 230; 1~ 230; 1~ 400...450 ∆ 450...500

400...500 ∆ 500...690

500...690 500 ∆

400...500 ∆ 600...690

Tolerance [%] ±10 +6/-10 +6/-10 +6/-10 ±10 ±10 ±10 +5/-10 ±10 Frequency [Hz] 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 Power consumption [W]

14 13 26 29 64 80 135 185 653 860 800 ∆ 700

1340 ∆ 800

1200

2900 ∆ 2200

3600 ∆ 3300

Current consumpt. [A]

0.14 0.12 0.12 0.13 0.29 0.35 0.59 0.82 2.50 3.4 1.45 ∆ 0.91

2.0 ∆ 0.9

1.2

6.5 ∆ 2.3

4.9 ∆ 3.0

Blocking current [A]

< 0.25 < 0.2 < 0.3 < 0,4 < 0.7 < 0.8 < 0.9 < 0.9 3.75 4.5 at 450 V ∆ 8.5

at 500 V ∆ 8.5

at 690 V

4.4

at 500 V ∆ 8.5

at 400 V ∆ >25

at 400 V ∆ >30

Air flow [m3/h] freely blowing

156 180 375 440 925 1030 1860 1975 - - -

Air flow [m3/h] at working point

- - - - 800 2.5 A

750 3.2 A

1500 1.26 A

(450V ∆)

1600 1.6 A

(500V ∆)

1500 0.7 A

(690V

)

1600 1.65 A

(500V ∆)

4200 3.6 A

(400V ∆)

4250 4.1 A

(400V ∆) Max. ambient temperature [° C]

< 60 < 85 < 75 50 < 55 < 55

Useful lifetime of grease

appr. 25000 h/60°

appr. 45000 h/60°

appr. 45000h/60°

appr. 40000 h

appr. 30000 h/40°

Protection Impedance ➀

Temperatur detector: UN ≤ 230 V~;

IN ≤ 2.5 A~

➀ Increased losses due to increased current with a blocked rotor will not result in a winding temperature, higher than permissible for the insulation class being involved.

U1 V1 W1 U2 V2 W2 TK TKPE

M~ϑ

at

Connection

U1-W2V1-U2W1-V2

U2-V2-W2

Page 25: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-15

3ADW000165R0201_Technical_Data_e_b

Monitoring the DCS 500 power section

it is here not mounted on a heat sink but close tothe fan air outlet. The detector thus measures thepower section’s radiated heat and any changesin the cooling air temperature and volume. Sincethe cooling air volume can only be detectedindirectly, a differential-pressure switch has beenadditionally fitted at the unit’s housing, alwayslocated close to the power terminals.The resistance change proportional to thetemperature is acquired and evaluated in theunit’s software. If the temperature rises above theparameterized value, then first an alarm will beoutputted, and - if the temperature continues torise - an error message. The value to be set forthis parameter must not be more than 10 de-grees above the permissible ambient tempera-ture.The differential-pressure switch compares thepressure inside the unit with the normal atmos-pheric pressure. If the fan has been switched onand the unit door closed (and no unit casingshave been removed), the pressure switch willsignal “Cooling conditions ok”, which means thedrive may be enabled. There is no need to setany specific differential pressure (recommenda-tion: centre setting).

a.The power sections of sizes C1 and C2 aremonitored by an electrically isolated PTC ther-mistor detector, which is installed on the likewiseelectrically isolated heat sink near the thyristors.The resistance change proportional to thetemperature is acquired and evaluated in theunit’s software. If the temperature rises above acertain value predefined by the unit codinginvolved, then first an alarm will be outputted,and - if the temperature continues to rise - anerror message. This means that changes in therated cooling conditions, such as cooling airvolume and temperature, the fan itself, overloaddue to an excessively high load current, etc. aredetected.

b.The size-A5 power section is likewise monitoredby an electrically isolated PTC thermistor detec-tor, which is installed on the non-isolated heatsink in an isolated configuration. Evaluation ofthe resistance and the protection effect corre-spond to those mentioned for point (a.) above.

c. The size A6 and A7 power section is not directlymonitored by an electrically isolated PTC ther-mistor detector. For this size, the same thermis-tor detector is used as for (a.) and (b.) above, but

DCS 500 valid for DCS 500B / DCS 600 / DCF 500B / DCF 600

Page 26: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 2-16

3ADW000165R0201_Technical_Data_e_b

Page 27: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 3-1

3ADW000165R0201_Technical_Data_e_b

The control board is based on the 80186EM micro-processor and the ASIC circuit DC94L01.

Fig. 3.1/1 Layout of the control board SDCS-CON-2

Fig. 3.1/2 Seven segment display of theSDCS-CON-2

- Digital outputs are forced low.- Programmable analogue outputs are reset tozero, 0V.

Seven segment displayA seven segment display is located on the controlboard and it shows the state of drive.

Memory circuits and the back-upThe program including system and parameter val-ues is stored at Flash PROM D33. Different pro-grams can be downloaded directly to thesePROMs. Application functionality and parametervalues are saved in the Flash PROM D35.Fault and Alarm messages -the time of their ap-pearance and some other values like the operatinghours and so on- are stored in static RAM circuits.They have a back up capacitor of 1 F, which lastsminimum 8 hours, typically several days. It takesabout 30 minutes to charge the backup capacitor.

ASIC functionASIC = Application Specific Integrated CircuitMost of the measurements and control functions forthe DCS500 are done in the ASIC:

- communication with control panel (RS 485)- communication with field exciters (RS 485)- measurement- watchdog function- A/D and D/A-conversion control- thyristor firing pulse generation

Watchdog functionThe control board has an internal watchdog. Thewatchdog controls the running of the control boardprogram. If the watchdog trips, it has the followingeffects:

- Writing to FPROM is disabled.- Thyristor firing control is reset and disabled.

0.7s 0.7s 0.7s

RAM/ROM memory test error

During download sequence

Normal situation

Program is not running

Alarm

Fault

3 Control boards3.1 Control Board SDCS-CON-2

1

S1

R2716

23

222324

1

X4 X5 X6 X710 1 10 1 10 1 8

X310 1

X33

X37 X14

X18

X17

X12

X13

X2

ASIC

X21 X11

CPU

D33

D35

S2A1B1

A1B1

B1A1

21

21

A1B1 2 1 2 1

H1

233.5

247

21

Ch

AI2- X3:7

22-23

n. c. to +10V 22 kΩ ->+10V

23-24

*

5 V 12/24 V

5 V 12/24 V 13 mA

S1

*

123

222324

123

222324

123

222324

123

222324

123

222324

*

*

1 5

X16 B1A1 X1

V260

DDCC+

S2

*

S4 *

*

X34

S4**

247

TxD

RxD

1 562

1 7

82

1 7

82

1 7

82

1 562

1 7

82

1 562

Con2_1_c.dsf

1 562

Back upcapacitor

Jumper coding

default value

Terminal

Input AI2 used for temperature measurement via PTC

single ended:

Characteristics for pulse encoder inputs

All supports are conductiveconnected to GND

differential:

Initialisation with default values; read parameters from D33

Normal start; read parameters from D35 after initialisation

Tacho (+ and -) connected to AITAC; X3:4 connected to GND

Tacho (+ and -) connected to AITAC

Bootstrap loader (can only be used with additional

hardware and a PC-program)

Position of jumpers 1-2, 3-4 is random;

7-8 is parking position for jumper 5-6

blue

grey

Position, if SDCS-IOB-3 is connectedfor more details, see SDCS-IOB-3

Starting condition for DOWNLOAD software to D33

Page 28: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 3-2

3ADW000165R0201_Technical_Data_e_b

Fig. 3.1/3 Auxiliary power distribution on the board SDCS-CON-2

RS485 serial communication channelsThe control board has two RS485 channels. The firstchannel is used for field exciter control of DCF 501B/502B, DCF 503A/504A or DCF 601/602 (terminalsX16:1...3) and the second for the control panel (CDP)at terminals X33 or X34. The terminals X33 and X34are wired up in parallel internally.

DDCS Channel integratedThe control board SDCS-CON-2 has an integratedDDCS (Digital Drive Control System) channel with atransfer rate up to 4 Mbits/s. This channel (V260) canbe used for fieldbus modules with the DCS 500Bconverters or for the 12_PULE LINK with DCS 600converters. The terminals X16:4 and 5 are providedfor power supply of the modules (+24 V / ≤150 mA).

Fig. 3.1/5 Connection of the DDCS channel withpower supply to the control board SDCS-CON-2

Fig. 3.1/4 Connection for field supply units DCF xxxto the RS485 Communication Interface ofthe SDCS-CON-2 board.

Supply voltage +5 V +15 V -15 V +24 V +48 V1 +48 V2

Undervoltage tripping level +4.55 V +12.4 V - 12.0 V +19 V +38 V +38 V

Test terminals X37: B4 / B5 B10 B8 B11 B12 --------

Supply voltage monitoringThe control board monitors the following voltagelevels:

threshold a trip signal is generated.

In addition to that there is a monitoring function for the5 V level. If +5 V drops under the tripping level, itcauses a master reset by hardware. All I/O registersare forced to 0 and the firing pulses are suppressed.

Auxiliary power distributionThe electronic power supply board SDCS-POW-1(see separate chapter) generates different levels ofvoltages. Some of them are transferred via theCON-2 board directly to the boards, where they areused, others are manipulated and then transferred.

The electronic power supply system with the differentvoltage levels is monitored in two ways. There is asignal powerfail primary, which monitors the inputpower supply voltage of the POW-1 board and asignal powerfail secondary, which monitors the lowvoltage levels. If one voltage level drops below the

1 5

X16

GND

µPTxD/RxD

RS485

RxD

TxD

SDCS-CON-21 5

X16

GND+24 V/≤ 150 mA

Partner

blueblue

grey grey

blueblue

grey grey

+48V1

X37X37

+48V2

+24V

+15V

-15V

+5V

X37:A12,B12

A13

A11,B11

A10,B10

A8,B8

B2,B3,B4,B5

B8

A7

Reg.

X2:

SDCS-CON-2SDCS-POW-1

0VAGND

A9,B9

0VGND

A2,A3,A4,A5

X33:1

X34:1

Reg.

B1

Reg.

X16:4Reg.

+24 V for RS-485

+24 V Digital output

-10V / ≤ 5 mA ref. source

+10V / ≤ 5 mA mA ref. source

Watchdog

For Power Interface board andfield exciter

For digital input supply

For SDCS-CON-2 processor and its periferals

26 wireFlatcable Supply for signal

measurments

Powerfail prim. ("0" = o.k.)

Ref.regul.

+24 V for external fieldbus module ≤ 150 mA

Con2_2_d.dsf

max. 10 m

Page 29: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 3-3

3ADW000165R0201_Technical_Data_e_b

Fig. 3.1/6 Terminal connection of the SDCS-CON-2 board

Digital and analogue I/O connection of the SDCS-CON-2

Reso- Input/output Scaling Power Common Remarkslution values by mode[bit] Hardware range

±90...270 V12 + sign ±30...90 V R 2716/ ±20 V ➀ ➁ ➂ ➃

±8...30 V Software

12 + sign -10...0...+10 V Software ±20 V ➀ ➁ ➂

11 + sign -10...0...+10 V Software ±40 V ➀ ➁ ➂

11 + sign -10...0...+10 V Software ±40 V ➀ ➁ ➂

11 + sign -10...0...+10 V Software ±40 V ➀ ➁ ➂

≤5 * mA for external use≤5 * mA e.g. reference pot.

11 + sign -10...0...+10 V Software ≤5 * mA11 + sign -10...0...+10 V Software ≤5 * mAanalogue ±3 V fixed ≤5 * mA 3 V = nom. conv. curr.

Encoder supply Remarks

Inputs not isolatedImpedance = 120 Ω, if selectedmax. frequency ≤300 kHz

Sense lines for GND and supply to correct volt-age drops on cable (only if 5V/12V encoder is inuse)

5V/ ≤0.25 mA * Selectable on POW-1 board12V/24V ≤0.2 mA *

Input value Signal definition Remarksby

0...8 V Software = "0" status16...60 V = "1" status

Output value Signal definition Remarksby

DO8: see SDCS-POW-150 * mA Software Current limit for all 7 outputs =

160 mADo not apply any reversevoltages!

➀ total smoothing time ≤2 ms➁ -20...0...+20 mA by external 500 Ω resistor➂ 4...20 mA by ➁ + Software function➃ Remove jumper S4:1-2 and 3-4 if SDCS-IOB-3 is used* short circuit proof (but a short-circuit can cause a malfunction of the drive)

The terminal connectors X3: ... X7: and X16: are removable. Whenconnecting the terminal blocks to the CON-2 board, please start withthe left connector at first and make sure, that they will be placed onthe board in the correct sequence and without spaces in between.

X2:

X1:

AITAC

90-270 V

30-90 V

8-30 V

+24V

AI4

ChA +

ChA -

ChB +

ChB -

ChZ +

ChZ -

GND

0 V

R2716

+10V

S1:23-24

100µ

+48 V/ ≤50 mA

100k

1n1n

100n

100k

100k 100k

Power-Source

Sense GND

Sense Power +

0V

AI2

AI3

AI1

-

+

-

+

-

+

-

-

-

+

AO1AO2

+/- I-act

47.5100µ

100n

0V (AOx)

+10V

0V

-10V

DI1

DI2

DI3

DI4DI5

DI6

DI7

DI8

47.5k

220n10k

4.75k

DO4

DO5

DO7

DO1

DO2

DO3

DO6

22 K

3

4

5

8

7

6

7

9

X6:1

2

3

4

5

6

7 8

10

4

5

7

1

2

3

6

4

2

3

6

5

9

10

8

9

10

2

4

5

7

2

3

6

8

9

10

8

X3:1

X4:1

X5:1

X7:

SDCS-CON-2 Software

+24V 7 8 910 11 12

+24V 13141516 17 18

+24V4 5 6

S1:1 2 3

S1:

GND

1 2

3 456

S4

Con2_3_d.dsf

-

+

0 V

Page 30: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 3-4

3ADW000165R0201_Technical_Data_e_b

Page 31: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 4-1

3ADW000165R0201_Technical_Data_e_b

AC Supply voltage

Supply voltage 115 V AC 230 V ACTolerance -15%/+10% -15%/+10%Frequency 45 Hz ... 65 Hz 45 Hz ... 65 HzPower consumption 120 VA 120 VAPower loss ≤60 W ≤60 WInrush current 20 A / 20 ms 10 A / 20 msMains buffering min 30 ms min 30 ms

Supply voltage +5 V * +15 V +24 V +48 V2Test terminals X 5 B X3 A X3 B heat sink T 10

* The 5 volt level can be checked, if 5 volt is selected!

4 Power Supply Board4.1 Power Supply Board SDCS-POW-1

Fig. 4.1/1 Layout of the SDCS-POW-1 board

Output X96-DO8Potential isolated by relay (NO contact)MOV- element (275 V)Contact rating: AC: ≤250 V~/ ≤3 A~

DC: ≤24 V-/ ≤3 A-or ≤115/230 V-/ ≤0.3 A-)

The SDCS-POW-1 board is designed for DCS 500converter modules and is mounted on the elec-tronic support. This board is used for all types ofmodules independent from current or voltagerange.

The SDCS-POW-1 works on a switched mode ba-sis in fly back configuration. It generates all neces-sary DC voltages for the SDCS-CON-2 and allother electronic boards. The input voltage can be

selected via the switch SW1 either to 230 V AC orto 115 V AC. The following figure shows the in-structions for the selection of the AC input voltageand for the selection of the encoder supply voltage.

Backup supplyThese two terminals are used to add additional ca-pacitance (e.g. KJ 2001) to the existing ones to in-crease the mains buffering time. More detailed datais available on request via your ABB representa-tive.

SD

CS

-PO

W-1

LNX96 X9923

0 V

115 V2 1

SW1

-+

X95

M1

1

X3713

1426

X5 X4 X3

5 V

15 V

24 V

220

135

DO8X3X4X5

SW1

*

*

X5 X4 X3

230 V

110 V

230 V

115 V

230 V 115 V*

*

*

T 10

12 V

Pow1_f.dsf

BA

BA

BA 15V

24V

BA

BA

BA 15V

24V

BA

BA

BA 15V

24V

BA

BA

BA 15V

24V

BA

BA

BA 15V

24V

AC supply selection

AC supply

Backup supplyfor SDCS-POW-1

Encoder supply selection

Relay output

Jumper coding

default value

line potential !

Sense-function

yes

yes

no

no

If an SDCS-CON-2 (without I/O board SDCS-IOB-3) together with a pulse encoder is used forspeed measurement, the incremental encodersupply voltage must be selected by jumpers X5,X4 and X3.

Page 32: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 4-2

3ADW000165R0201_Technical_Data_e_b

Page 33: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-1

3ADW000165R0201_Technical_Data_e_b

5 Power interface boards5.1 Power Interface Board SDCS-PIN-1x

The power interface board is used for convertermodules model C1. There are 2 different versionsin use. The used types are:- SDCS-PIN-11 for 25 A, 50 A and 75 A converters

at 500V- SDCS PIN-12 for 50 A converters at 600 V

The SDCS-PIN-1x boards consists of:- firing pulse circuits and pulse transformers- measurement of the armature current via current

transformers- snubber circuit for thyristors protection

(consists of RC circuits and MOV elements)

Fig. 5.1/1 Layout of the SDCS-PIN-1x board.

- AC and DC high ohmic voltage measurement- heat sink temperature measurement via PTC

sensor- scaling for rated current, zero current detection

and HW type coding- If the SDCS-PIN-11 connection board is installed

in a DCF50x-0025...0075 / DCF60x-0025...0075,then the resistors R113, R116 and R119 are notbuild-in

Note:If this PCB is used as a spare part for a DCF.... ,then the resistors R113/R116/R119 (value = 0 Ω)must be removed.

Table 5.1/1 Settings of the SDCS-PIN-1x board if aDCS converter is equipped with it by ABB

Board used as a spare part:- default: all jumpers W10-W82 are

in condition- ensure the correct converter type

related settings

Board type PIN 11 PIN 12Current transformer ratio 1500:1 1500:1Max. rated voltage [V] 500 500 500 600Rated current [A] 25 50 75 50W10 2Q= ; 4Q= ← ← ← ←W15 zero current detectionW17 rated current scalingW18 rated current scalingW80 HW type codingW81 HW type codingW82 HW type coding

T11 T24T14 T21,T13 T26,T16 T23 T15 T22 T12 T25

X12

W18,W17,W15

W10

W81 W80X13

1 8

16

T101 T102 T103

SDCS-PIN-1X

X22

W82

X121(GND)

X122(IACT)

U1 C1 V1 D1 W1 R118

R112R115

16

1 8

282

PTC

265

R116 R113R119

XT11 XT24XT14 XT21 XT13 XT26 XT16 XT23 XT15 XT22 XT12 XT25

line potential !

indicates a removed jumper

Page 34: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-2

3ADW000165R0201_Technical_Data_e_b

The power interface board is used for DCS con-verter modules construction type C1 and C2. Thereare different versions in use. The used types are:

- SDCS-PIN-205B for 100 A...1000 A Conv. at 500 Vincluding the 3-phase field supply converters DCF...

- SDCS-PIN-206B for 110 A...450 A Conv. at 600 V

The SDCS-PIN20xB can replace the SDCS-PIN-20x and PIN-20xA but not vice versa.

The SDCS-PIN-20x board consists of:- firing pulse circuits with pulse transformers- measurement of the armature current- snubber circuit for thyristor protection

(consists of RC circuits in parallel of the thyristorsand RCD network)

- AC and DC high ohmic voltage measurement- rated current scaling with burden resistors, zero

current detection and HW voltage type coding- interface for heat sink temperature measurement

with a PTC sensor- fuses for overvoltage protection and voltage

measuring- the same board will be used without any modifi-

cation at a converter used for three-phase fieldsupply

Fig. 5.2/1 Layout of the SDCS-PIN-20x (20xA), 20xB board.

Spare partThe protection of the power part is done by usingRC circuits. Snubber circuits are wired in parallel toeach thyristor with fuses in between. RCD ele-ments are protected by the fuses F 101 to F 103.The AC voltage measurement is taken from behindthe fuse.

Fuse data: Bussmann KTK-R-6A (600V)

The power interface board SDCS-PIN205 can beused as a replacement of SDCS-PIN-21, 22 and25. The board SDCS-PIN-206 can be used as a re-placement of SDCS-PIN-23 and 24, but not vice-versa! In case of a converter with 450 A / 520 A /700 A at 500 V or a converter of 450 A at 600 V ad-ditional actions have to be taken into account.

NoteIf this PCB is used as a spare part for a DCF..., nomodifications are necessary!

5.2 Power interface board SDCS-PIN-20x/SDCS-PIN-20xB

SDCS-PIN-20X

X121 8

916 X131 8

916

T24

T22

T26

T11

T15

T13

T14

T12

T16

T21

T25

T23

X22 X3 X4

X94

X91

X92

X93

X95

123

35

35

123

F101

F102

F103

X121 (IACT)X120 (GND)

U1

V1

W1

C1 D1

280

253

PTC

U1 V1 W1

X5X6

W10

W80

W81

W82

R24

8R

249

R25

0R

251

R25

2R

179

R17

8R

177

R17

6R

175

R17

4R

173

R17

2R

171

R17

0R

169

R16

8R

167

R16

6R

165

R16

4R

163

R16

2R

161

R16

0

P126 P127

P123

P122

P125

P124

P131

P130

P128 P129

MOV

R15

1R

149

R15

0

C108

Removed on PIN-20xB

P125

P124

X94

C1

C108

C109

Adde

d on

PIN

-20x

B

linepotential!

Page 35: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-3

3ADW000165R0201_Technical_Data_e_b

Table 5.2/1 Settings of the SDCS-PIN-20xB board for 2-Q converters if a DCS converter is equipped with it by ABB

2-Q Converters

Table 5.2/2 Settings of the SDCS-PIN-20xB board for 4-Q converters if a DCS converter is equipped with it by ABB

4-Q Converters

Boa

rd u

sed

as a

spa

re p

art:

- de

faul

t: al

l res

isto

rs, r

epre

sent

ing

a ju

mpe

r W

xx /

Rxx

are

in

con

ditio

n-

ensu

re th

e co

rrec

t con

vert

er ty

pe r

elat

ed s

ettin

gs

Board type PIN 205B PIN 206BCurrent transformer ratio 1000:1 600:1 3000:1 1000:1 600:1

Rated voltage [V] 500 600Rated current [A] 100 125 180 225 315 405 470 610 740 900 100 245 405

W10 2-Q/4-Q selectionW80 HW type codingW81 HW type codingW82 HW type codingR248 HW type codingR249 HW type codingR250 HW type codingR251 HW type codingR252 HW type codingR149 33 Ω zero current detectionR150 47.5 Ω zero current detectionR151 100 Ω zero current detectionR160 1k Ω rated current scalingR161 1k Ω rated current scalingR162 332 Ω rated current scalingR163 332 Ω rated current scalingR164 332 Ω rated current scalingR165 332 Ω rated current scalingR166 332 Ω rated current scalingR167 47.5 Ω rated current scalingR168 33.2 Ω rated current scalingR169 33.2 Ω rated current scalingR170 33.2 Ω rated current scalingR171 33.2 Ω rated current scalingR172 33.2 Ω rated current scalingR173 33.2 Ω rated current scalingR174 33.2 Ω rated current scalingR175 33.2 Ω rated current scalingR176 33.2 Ω rated current scalingR177 10 Ω rated current scalingR178 10 Ω rated current scalingR179 10 Ω rated current scaling

Board type PIN 205B PIN 206B1000:1 600:1 3000:1 1000:1 600:1

500 600100 140 200 250 350 450 520 680 820 1000 110 270 450

W10 2-Q/4-Q selectionW80 HW type codingW81 HW type codingW82 HW type codingR248 HW type codingR249 HW type codingR250 HW type codingR251 HW type codingR252 HW type codingR149 33 Ω zero current detectionR150 47.5 Ω zero current detectionR151 100 Ω zero current detectionR160 1k Ω rated current scalingR161 1k Ω rated current scalingR162 332 Ω rated current scalingR163 332 Ω rated current scalingR164 332 Ω rated current scalingR165 332 Ω rated current scalingR166 332 Ω rated current scalingR167 47.5 Ω rated current scalingR168 33.2 Ω rated current scalingR169 33.2 Ω rated current scalingR170 33.2 Ω rated current scalingR171 33.2 Ω rated current scalingR172 33.2 Ω rated current scalingR173 33.2 Ω rated current scalingR174 33.2 Ω rated current scalingR175 33.2 Ω rated current scalingR176 33.2 Ω rated current scalingR177 10 Ω rated current scalingR178 10 Ω rated current scalingR179 10 Ω rated current scaling

Rated current [A]

Rated voltage [V]Current transformer ratio

indicates a removed jumper

Page 36: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-4

3ADW000165R0201_Technical_Data_e_b

Fig. 5.2/2 Typical armature circuit thyristor converter diagram with SDCS-PIN-20x (PIN-20xA), PIN-20xB boardfor a 2Q/4Q C1/C2 type converter

V11

V24

V21

V14

1.4

2.1

2.4

1.1

2.6

V26

V13

1.3

2.3

1.6

V23

V16

2.2

V22

V15

1.5

2.5

1.2

V25 V12

KG KGG KG K

G KG KG K KG

KGG K

KGG K

X12:

U1

V1

W1

C1

(+)

D1

(-)

F10

1

3S

TW

A

VW

16

UV

UU

144

0V

5M /

6M

GN

DI

IDC

8,13

9,10

IDC

M11

,12

1X

4:

3

X3:

31

N/1

P1

T51

P2

P2

P1

T53

N/1

W81

AC

OD

1

AC

OD

21513

AN

TC

2

1X

22:

3R

57H

WC

IN4

1W

10 W80

7B

ZP

4

+48

V1

SR

1

GN

DI

SR

2

BZ

P5

BZ

P6

8,61011

12,1

4

4,29

BZ

P2

BZ

P3

BZ

P1

X13: 3 51

0 V

+ 4

8 V

1

W82

UA

+6

UA

-15

820R

1k5

3k3

1k5

S1

S2

S1

S2

PE

RE

VE

RS

E

FO

RW

AR

D

1 2 3 4 5 6K G KGKKGKGK KGGGKGKG K GKGKG

2.6

1.6

2.5

1.4

2.3

1.2

2.1

1.5

2.4

1.3

2.2

HW

CD

D5

7

HW

CO

D3

5N

C

NC

1.1

F10

2

F10

3

6A

C1W1

V1

U1D1

191731293135331192725X

6:

191731293135331192725X

5:

* V

alue

sch

ange

d at

PIN

-20x

B6

x 15

Ω

Removed on PIN-20xB

**

**

**

*

p20x_d.dsf

Con

trol

boa

rdA

rmat

ure

cur

rent

mea

suri

ng r

esis

tan

ces

AC

/DC

vol

tage

mea

surin

g ci

rcui

ts

HW

-co

ding

Firi

ng p

ulse

cha

nnel

son

ly in

cas

e of

4-Q

co

nver

ters

see

tabl

efo

r R

1xx

PO

WE

R IN

TE

RF

AC

E B

OA

RD

SD

CS

-PIN

-20x

see

tabl

e fo

r R

2xx

Page 37: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-5

3ADW000165R0201_Technical_Data_e_b

5.3 Galvanic isolation - T90, A92

The Galvanic isolation is an option for converters inthe current range 2050...5150 A and rated voltages≤1000 V. For converters with a rated voltage of1190 V and 12-pulse serial > 2x 500 V the galvanicisolation is a standard equipment. It is used to re-place the high-ohmic resistance voltage measure-ment and gives the advantage of a total isolationfrom power part to electronic part.

The transformer T90 and the DC transducer A92are located outside the converter module. The in-ternal AC and DC voltage measurement channelsare opened and connected to the T90 and A92units.

Hard and software settings:

Voltage coding on measuring board

Construction type A5 / A6 / A7 (C4) Conv. nom. voltage [V] *

Y=4 (400V) Y=5 (500V)

Y=6 (600V) Y=7 (690V) Y=8 (790V) Y=9 (1000V) Y=1 (1190V)

Rated mains voltage [V AC] 220…500 270…600 300…690 350…790 450…1000 530…1190

Value f. conv. nom. volt at SET(TINGS) block *

500 600 690 800 1000 1200

Measuring board SDCS- PIN-51 PIN-51 PIN-51 PIN-51 PIN-51 PIN-51 Resistors W1…W26

all resistors are 0 Ω

Galvanic isolation

Resistors Rx on PIN51 27.4 kΩ 27.4 kΩ 27.4 kΩ 27.4 kΩ 27.4 kΩ 27.4 kΩ

DC-DC transducer A92 8680A1

Switch position RG * 7 (675 V) 6 (810 V) 5 (945 V) 4 (1080 V) 2 (1350 V) 1 (1620 V)

Transformer T90 3ADT 745047

Secondary Terminals * 2U1 2V1 2W1 2N

2U2 2V2 2W2 2N

2U3 2V3 2W3 2N

2U4 2V4 2W4 2N

2U5 2V5 2W5 2N

2U6 2V6 2W6 2N

* 12-pulse serial and sequential have a different selection between S CONV NOM VOLT (42.08) and the scaling of measurement channel. See 12-pulse manual for DCS 600.

Page 38: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-6

3ADW000165R0201_Technical_Data_e_b

Fig. 5.3/1 Typical armature circuit thyristor converter diagram with SDCS-PIN-41 and SDCS-PIN-51 boards for a4-Q A7 type converter with galvanic isolation

*

V1

1

V2

4

V21

V14

1.4

2.1

2.4

1.1

2.6

V2

6

V1

3

1.3

2.3

1.6

V23

V16

2.2

V2

2

V1

5

1.5

2.5

1.2

V25

V12

KG KGG KG K

G K G KG KKG

KGG KKG G K

X12

:X

12:

V1

W1

SD

CS

-PIN

-51

C1

(+)

D1

(-)

R11

C11

C24

F1

1

R13

C13

C26

F1

3

C15

C22

R15

F1

5

C14

C21

F14

R14

F16

C16

C23

R16

F12

C12

C25

R12

1M

B7

3S

TW

A

AN

TC

2A

8

UA

-

UA

+

VW

1516 6

UV

UU

144

B1

A6

A1

A2

A7

0V0V

500

400

501

401

200

300

100

5M

201

301

101

W22

W17

W2

3

W1

8

W6

W12

W1

1MW

7

W1

3

W2

1M

W1

9W

20

W8

W1

41M

W3

W9

W15

W4

R19

GN

DI

IDC

8,1

3

9,1

0

IDC

M11

,12

A5,

B2

A4,

B4

R20

R21

A3,

B3

R10

R17

R18

R15

R16

R13

R14

R11

R12

R8

R9

R6

R7R26

R25

47R

47R

100R

47R

47R R4

R5

R2

R3

560R

270R

120R

18R

33R

68R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

R24

R23

R22

1X

22:

3

W2

1

W1

1

W1

6

W5

1M

D1

C1

W1

V1

U1

R57

R1

1X

25:

2

X24

:

21

X23

:

21

GD

W70

W81

HW

CD

D5

HW

CIN

417

AC

OD

1

AC

OD

2

HW

CO

D3

15

X12

: 513

B8

B5

W10

X12

:B

6

B1

NC

B2

W8

0

7B

ZP

4

+48

V1

SR

1

GN

DI

SR

2

BZ

P5

BZ

P6

8,6 1011

12,1

4

4,29

BZ

P2

BZ

P3

BZ

P1

X13

: 3 51

4B

5

0 V

FW

D

+ 4

8 V

1

A5,

A6

A4

A7,

A8

A2,

A3

B4

B3

5 6

B7

B6

X13

:B

8

2 31

W82

W71

W83

W72

0V

A7,

B7

A1,

B1

A2

A8,

B8

A6,

B6

A4,

B4

A3,

B3

X11

3:

A5,

B5

A9,

B9

A10

,B10

A7,

B7

A1,

B1

A2

A6,

B6

A4,

B4

A3,

B3

A8,

B8

A10

,B10

A5,

B5

A9,

B9

X11

3:

GA

2.4

CB

CA

GB

1.1

2.6

GC

CC

1.5

SD

CS

-PIN

-41

1.3

CD

GE

CE

2.2

GF

A8,

B8

A1,

B1

A2

A7,

B7

A9,

B9

A4,

B4

A3,

B3

X21

3:

A10

,B10

A6,

B6

A5,

B5

CF

GD

A2

A4,

B4

A3,

B3

A1,

B1

A6,

B6

A8,

B8

A9,

B9

A7,

B7

A10

,B10

A5,

B5

X21

3:

A2

A4,

B4

A1,

B1

A3,

B3

A6,

B6

A8,

B8

A7,

B7

A9,

B9

A10

,B10

A5,

B5

X21

3:

GA

2.5

CB

CA

GB

1.2

2.3

GC

CC

SD

CS

-PIN

-41

A2

A4,

B4

A3,

B3

A1,

B1

A9,

B9

A7,

B7

A6,

B6

A8,

B8

A5,

B5

A10

,B10

X11

3:

1.4

1.6

CD

GE

CE

2.1

GF

CF

RE

V

R24

R21

R26

R22

R23

R25

W2

4W

25W

26

1k5

820

R1k

53k

3

820

R1

k53k

38k

21k

5

PE T

51P

2

400

0/1

400

0/1

P1

T52

P2

P1

S1

S2

S1

S2

U1

Fast

-on S1

p41_51_A7.dsf

Con

trol

boa

rd

PO

WE

R I

NT

ER

FA

CE

BO

AR

D

Arm

atur

e cu

rren

t m

easu

rem

ent

AC

/DC

vol

tage

me

asur

emen

t

Firi

ng p

ulse

ch

anne

ls

HW

-cod

ing

jum

per

s

T90

F90

Rx

2NS

SD

CS

-PO

W-1

X99

:1

X99

:2

F11

109

2017

A92

12

==

~=

Rx

Rx

Rx

Rx

Rx

rem

oved

wire

s

aux.

sup

ply

230

V A

C

resi

stor

s, to

be

sold

ered

in p

aral

lel t

o 5

M

hyb

rid; v

alue

s se

e ta

ble

befo

re

Page 39: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-7

3ADW000165R0201_Technical_Data_e_b

5.3.1 DC-DC transducer A92

Fig. 5.3/2 Principle circuit diagram of the DC-DC transducer A92

112.0

10.0

2.0

100.

0

Side view

76.0

70.0

50.060.0

80.0

7.0

5.0

Sna

p-on

mou

ntin

g on

DIN

462

77 ra

il

Buttom view

Fig. 5.3/3 Dimensions in mm Fig. 5.3/4 Location of terminals

Data

Selectable voltage gains: 675 810 945 1080 1215 1350 1620 V DCSwitch position 7 6 5 4 3 2 1

Output voltage: 9,84 V / 5 mAAuxiliary power: 230 V ± 15 %; 50/60 Hz; 3 WClearance in air: Auxiliary power to Output: >13 mm

Input/Output to Auxiliary power: >14 mmInsulation voltage: 2000 VInsulation test voltage: 5000 VAmbient temperature range: - 10 …+ 70 °CWeight: appr. 0.4 kg

The voltage gain and frequency response is especially designed for DCS 500Band DCS 600 converters.

Ωk

Ω6 M17

20OPAMP

TRANSDUCER1 : 1

9

10

10nF

230 V AC+15V0V

-15V0V

1

2

Ω6 M RG

GAIN7 STEPS

POWER SUPPLY

Inputvoltage

Outputvoltage

appr. 3.9

appr. 280nF

20

Gain selector

17

1 2 9 10

RG

Page 40: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-8

3ADW000165R0201_Technical_Data_e_b

5.3.2 Transformer T90

Fig. 5.3/5 Principle diagram of the transformer T90

Fig. 5.3/6 Dimensions in mm

RemarkThe terminals on the primary side of thetransformer are in special design (lug ter-minals).Handling hints: First turn the screw coun-ter-clockwise to the end stop, then swingout the shrowding cover.Put in the cable lug, swingin the shrowding cover andfasten the connection byturning the screw clock-wise.

1U

1V

1W

2N

S

2U12U22U32U42U52U6

2V12V22V32V42V52V6

2W12W22W32W42W52W6

1N

max 116m

ax 1

1013

0

118....120

130

80

5.2 x 7.7

DataSelectable transfer ratios Uprim: 502, 601, 701, 800,1000, 1200 V AC rmsOutput voltage: 7.3 V AC rmsInsulation voltage: 1200 VIsolation test voltage: 3500 VAmbient temperature range: - 10 …+ 70 °CWeight: 2.1 kg

Page 41: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-9

3ADW000165R0201_Technical_Data_e_b

5.4 Power Interface SDCS-PIN 41/SDCS-PIN-48/SDCS-PIN-5x

The Power Interface of DCS converter modulesmodel A5/A6/A7 and C4 from 900 A up to 5200 Aconsists of two boards - the Measuring boardSDCS-PIN-51 and the Pulse transformer boardSCDS-PIN-41.The following figures show the different connectionsbetween the SDCS-PIN-41 and SDCS-PIN-51board depending on the application 2- or 4-quad-rant and the construction type.

Converters, delivered from 1998 on, will beequipped with SDCS-PIN-41A, which is a full re-placement for converters, already in use.

Converters delivered from middle 2005 will beequipped with SDCS-PIN-48, which is a full re-placement for converters already in use.

Fig. 5.4/1 2-Quadrant application, no parallel thyristors - Construction type A5/A6/A7 (C4)

Fig. 5.4/2 4-Quadrant application, no parallel thyristors - Construction type A5/A6/A7

Fig. 5.4/3 4-Quadrant application, no parallel thyristors - Construction type C4

X213

SDCS-PIN-41/PIN-48

G

C

G

C

G

C

G

C

G

C

T1 T6 T3 T2 T5

V23

SDCS-PIN-41/PIN-48

B C D E F

X1

13

C

G

C

G

C

G

C

G

C

G

C

G

V13 V22 V12 V25 V15

X2

13

A

U1

SDCS-PIN-5x

SD

CS

-CO

N-x

V1

W1

C1

D1

X22 X122 X23 X24 X25

X1

2 S

X1

3 S

X4

13 S

X3

13 S

X1

3

X5

13

X1

13

X2

13

X4

13

X3

13

S2

S1

X1

3X

12

X1

2

A

C

G

V24 V14 V21 V11 V26 V16

X1

13

4q_c4a_a.dsf

X113

SDCS-PIN-41/PIN-48

G

C

G

C

G

C

G

C

G

C

G

C

T4 T1 T6 T3 T2

V24

SDCS-PIN-41/PIN-48

U1

SDCS-PIN-5x

SD

CS

-CO

N-x

V1

W1

C1

D1

X22 X122 X23 X24 X25

X1

2 S

X1

3 S

X4

13 S

X3

13 S

X1

3

X5

13

X1

13

X2

13

X4

13

X3

13

S2

S1

B C D E F

X1

13

C

G

C

G

C

G

C

G

C

G

C

G

V11 V26 V13 V22 V15

X2

13A

X1

3X

12

X1

2

V25 V12 V23 V16 V21 V14

F

X2

13

4q_c3a_a.dsf

V14

SDCS-PIN-41/PIN-48

U1

SDCS-PIN-5x

SD

CS

-CO

N-x

V1

W1

C1

D1

X22 X122 X23 X24 X25

X1

2 S

X1

3 S

X4

13 S

X3

13 S

X1

3

X5

13

X1

13

X2

13

X4

13

X3

13

S2

S1

B C D E F

X1

13

C

G

C

G

C

G

C

G

C

G

C

G

V11 V16 V13 V12 V15

X2

13

A

X1

3X

12

X1

2

2q_c34_a.dsf

Page 42: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-10

3ADW000165R0201_Technical_Data_e_b

Measuring board SDCS-PIN-51This board is always used together with SDCS-PIN-41 board. On this board there are the circuitslocated needed for current, voltage and tempera-ture measuring and for hardware coding.

The current is measured by current transformers atthe main AC inputs, rectified by a diode bridge andscaled with burden resistors to 1.5 V as rated cur-rent. The nominal current is adjusted by cutting outresistors (R1 ... R21) from the board according tothe current coding table. The resistors R22 ... R26are used for the current equal to zero detection.These resistors must be cut off too, according tothe current coding table.

Voltages (U1, V1, W1 and C1(+) and D1(-)) aremeasured by using high ohm resistor chains. Scal-ing of AC and DC voltage is done by activating

Pulse transformer board SDCS-PIN-41/PIN-41A/PIN-48

Fig. 5.4/5 Layout of the SDCS-PIN-51 board

1 MΩ resistors (= cutting out short circuit wires,which are represented by low ohmic resistors).The voltage measurement uses 5 resistor:U1: W1 to W5V1: W6 to W11W1: W12 to W16C1(+): W17 to W21D1(-): W22 to W26

If there is a need for voltage adaptation, all 5chains must be handled in the same way.

Note! Actual voltage signals U1, V1, W1, C1(+)and D1(-) of the main circuit are not galvanicallyisolated from the control board. Because of that acurrent of less than 1 mA will flow to earth.

When galvanically isolated measurement isneeded, please contact your ABB representative.

G4C4

G1C1

G6C6

G3C3

G2C2

G5C5

X113

X1

X213

X2

SDCS-PIN-41

T4 T1 T6 T3 T2 T5

A B C D E F

270

100line potential !

Fig. 5.4/4 Layout of the SDCS-PIN-41/PIN-41A/PIN-48 pulse transformer board

The board consists ofsix pulse transformerswith amplifiers.

Figure 5.4/6 Layout of the SDCS-PIN-52

X12

U1

V1

W1

D1

C1

SDCS-PIN-52

S3

W

X41

3

X31

3

X21

3

X11

3

X51

3

X13

S2 S1

X23 X24 X25

R1 . . . . . . . R21

X12S

X13S

X413S

X313S

X22 X122

X12

U1

V1

W1

D1

C1

W5 W4 W3 W2 W1

W16 W15 W14 W13 W12

W26 W25 W24 W23 W22

W11 W9 W8 W7 W6

W21 W20 W19 W18 W17

W5

R123

R22

R26

1 2 2 21 1

SDCS-PIN-51

S3

W10 W70

W80

W71

W81

W72

W82W83

305

100

213 4

PTC Conductivesupports

Isolatingsupports

One PTCTwo PTC

line potential !see diagrampower part

In the past some converters for linevoltages lower/equal 500 V had beenequipped with SDCS-PIN-52 boards.The SDCS-PIN-51 board serves as aspare part for those converters.

Page 43: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-11

3ADW000165R0201_Technical_Data_e_b

Table 5.4/1 Settings of the SDCS-PIN-51 board if aDCS converter is equipped with it by ABB

Board used as a spare part:- default: all jumpers Wxx, Rxx are in condition- ensure the correct converter type related settings

➀ the converters can be used at lower line voltage then specified by the y-value without hardware modifications, ifthe nominal line voltage applied to the converter is not lower than 45% for y=5...9 and not lower than 55% for y=4.

indicates a removed jumper

2-Q 4-QW10

2 Q - 4 Q coding

S312

34

Temp. sensor codingR 57 as a temp. sensor for A5, A6, A7

A5 A62500:1 4000:1

900 1200 1500 2000 1900 2050 2500 3000 2050 2600 3300 4000R1-R4 18 ΩR5 18 ΩR6 18 ΩR7 18 ΩR8 18 ΩR9 18 ΩR10 18 ΩR11 18 Ω

R12 18 ΩR13 18 ΩR14 18 ΩR15 18 ΩR16 18 ΩR17 33 ΩR18 68 ΩR19 120 ΩR20 270 ΩR21 560 ΩR22 47 ΩR23 47 ΩR24 47 ΩR25 47 ΩR26 100 Ω

4800 52002500:1

A7

code_tab_PIN1_PIN20_PIN51_d.dsf

Current codingConstruction typeCurrent transf. ratioRated current [A]

Rat

ed c

urre

nt s

calin

gZe

ro c

urre

ntde

tect

ion

A5 A6 / A7

Y=4 (400V)Y=5 (500V)

Y=6 (600V)Y=7 (690V)

Y=4 (400V)Y=5 (500V)

Y=6 (600V) Y=7 (690V) Y=8 (790V) Y=9 (1000V)

500 600 690 800 1000

PIN-51 PIN-51 PIN-51 PIN-51 PIN-51 PIN-51 PIN-51W1, 6, 12, 17, 22W2, 7, 13, 18, 23W3, 8, 14, 19, 24W4, 9, 15, 20, 25W5, 11, 16, 21, 26

0

A7Y=1

(>1000V)

A7

see chapter Galvanic isolation

Voltage codingConstruction typeConv. nom. voltage [V]

Value f. conv. nom. volt at SET(TINGS) block

= HW type coding

Measuring board SDCS

A6 / A71200 1500 2000 900 1500 2000 >2000 *500 500 500 600/690 600/690 600/690

W70W71W72W80W81W82W83

A5

all *

HW type codingConstruction typeCurrent [A]Voltage max. [V]

* see Software description

Page 44: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-12

3ADW000165R0201_Technical_Data_e_b

Fig. 5.4/7 Typical armature circuit thyristor converter diagram with SDCS-PIN-41and SDCS-PIN-51 boards for a 4-Q A7 type converter

*

V1

1

V2

4

V21

V14

1.4

2.1

2.4

1.1

2.6

V2

6

V1

3

1.3

2.3

1.6

V23

V16

2.2

V2

2

V1

5

1.5

2.5

1.2

V25

V12

KG KGG KG K

G K G KG KKG

KGG KKG G K

X1

2:X

12:

V1

W1

SD

CS

-PIN

-51

C1

(+)

D1

(-)

R11

C11

C24

F1

1

R13

C13

C26

F1

3

C15

C22

R15

F1

5

C14

C21

F14

R14

F16

C16

C23

R16

F12

C12

C25

R12

1M

B7

3S

TW

A

AN

TC

2A

8

UA

-

UA

+

VW

1516 6

UV

UU

144

B1

A6

A1

A2

A7

0V0V

500

400

501

401

200

300

100

5M

201

301

101

W22

W17

W2

3

W1

8

W6

W12

W1

1MW

7

W1

3

W2

1M

W19

W20

W8

W14

1M

W3

W9

W15

W4

R19

GN

DI

IDC

8,1

3

9,1

0

IDC

M11

,12

A5

,B2

A4

,B4

R20

R21

A3

,B3

R10

R17

R18

R15

R16

R13

R14

R11

R12

R8

R9

R6

R7R26

R25

47R

47R

100R

47R

47R R4

R5

R2

R3

560R

270R

120R

18R

33R

68R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

18R

R24

R23

R22

1X

22:

3

W21

W11

W16

W5

1M

D1

C1

W1

V1

U1

R57

R1

1X

25:

2

X24

:

21

X23

:

21

GD

W7

0

W8

1

HW

CD

D5

HW

CIN

417

AC

OD

1

AC

OD

2

HW

CO

D3

15

X12

: 513

B8

B5

W10

X1

2:B

6

B1

NC

B2

W80

7B

ZP

4

+48

V1

SR

1

GN

DI

SR

2

BZ

P5

BZ

P6

8,6 1011

12,1

4

4,29

BZ

P2

BZ

P3

BZ

P1

X13

: 3 51

4B

5

0 V

FW

D

+ 4

8 V

1

A5

,A6

A4

A7

,A8

A2

,A3

B4

B3

5 6

B7

B6

X1

3:B

8

2 31

W8

2

W7

1

W8

3

W7

20V

A7

,B7

A1

,B1

A2

A8

,B8

A6

,B6

A4

,B4

A3

,B3

X1

13:

A5

,B5

A9

,B9

A1

0,B

10

A7

,B7

A1

,B1

A2

A6

,B6

A4

,B4

A3

,B3

A8

,B8

A1

0,B

10

A5

,B5

A9

,B9

X1

13:

GA

2.4

CB

CA

GB

1.1

2.6

GC

CC

1.5

SD

CS

-PIN

-41

1.3

CD

GE

CE

2.2

GF

A8,

B8

A1,

B1

A2

A7,

B7

A9,

B9

A4,

B4

A3,

B3

X21

3:

A10

,B10

A6,

B6

A5,

B5

CF

GD

A2

A4

,B4

A3

,B3

A1

,B1

A6

,B6

A8

,B8

A9

,B9

A7

,B7

A1

0,B

10

A5

,B5

X2

13:

A2

A4

,B4

A1

,B1

A3

,B3

A6

,B6

A8

,B8

A7

,B7

A9

,B9

A1

0,B

10

A5

,B5

X2

13:

GA

2.5

CB

CA

GB

1.2

2.3

GC

CC

SD

CS

-PIN

-41

A2

A4,

B4

A3,

B3

A1,

B1

A9,

B9

A7,

B7

A6,

B6

A8,

B8

A5,

B5

A10

,B10

X11

3:

1.4

1.6

CD

GE

CE

2.1

GF

CF

RE

V

R24

R21

R26

R22

R23

R25

W24

W25

W26

1k5

820R

1k5

3k3

820

R1k

53k

38k

21k

5

PE T

51P

2

400

0/1

400

0/1

P1

T52

P2

P1

S1

S2

S1

S2

U1

Fast

-on S1

p41_51_A7.dsf

Con

trol

boa

rd

PO

WE

R IN

TE

RF

AC

E B

OA

RD

Arm

atur

e cu

rren

t mea

sure

men

t

AC

/DC

vol

tage

mea

sure

me

nt

Firi

ng p

ulse

ch

anne

ls

HW

-cod

ing

jum

per

s

Page 45: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-13

3ADW000165R0201_Technical_Data_e_b

5.5 Zero current detection SDCS-CZD-01A

This board is used for fast zero current detectionespecially for three phase field converter in MotorGenerator application. The board provides a safezero current detection also for other very high in-ductive loads.

The board is located on SDCS-CON-2 board andplugged on X12, X13 and X17.X17: is only used for mechanical reasons. Theelectrical function (connection to IOE-1) is un-changed.

All DCS/DCF converter are equipped with a zerocurrent detection by monitoring the current signal toa certain level.

Fig. 5.5/2 Connection between the SDCS-CZD-01A and SDCS-CON-2 board

The CZD-01A board has in addition a cathode / an-ode voltage measurement of all thyristors. The volt-age measurement provides a sharp detection ofDC load condition.

Basically two conditions need to be fulfilled to get asignal current equal to zero:• the current detection has to indicate current

equal to zero AND• the voltage detection has to indicate current

equal to zero

The activation of the board must be set in the soft-ware via parameter:

DCF500B 4.19 ZERO CUR DETECTDCF600 43.14 ZERO CUR DETECT

Fig. 5.5/1 Layout of the SDCS-CZD-01A board

Fig. 5.5/3 Principle diagram of SDCSCZD-01A

MP1 = '1'-signal ⇒ no zero currentMP1 = '0'-signal ⇒ zero current

With jumper J1 (not available with SDCS-CZD-01)the voltage detection can be set to two modes:with J1 in position 1-2:

all thyristors (V11/V13/V15) AND all thyristors(V12/V14/V16) must have blocking voltage

with J1 in position 2-3 (parking; default)all thyristors (V11/V13/V15) OR all thyristors(V12/V14/V16) must have blocking voltage

X13

:

SDCS-CZD-01A

X12

:

X17

:

MP1

106

47

1 2 3J1

*

* default position

SDCS-CZD-01AX13:

X13:

X23

:

X12:

X12:

X22

:

X17:

X17:

X27

:

SDCS-CON-2CZD01A.dsf

&

&

MP1

470k

D1 (-) C1 (+)

U1 V1 W1

CZD-01A

CON-2

CON-2 Power interface:SDCS-PIN-1xSDCS-PIN-20xSDCS-PIN-51

&

J1321

*

* default position

czd01_princ_b.dsf

to zerocurrent interface

voltage detection

current detection

Page 46: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 5-14

3ADW000165R0201_Technical_Data_e_b

5.6 Power signal measurement board SDCS-MP-1

Fig. 5.6/2 Connection between the SDCS-MP-1 and SDCS-CON-2 board

Fig. 5.6/1 Layout of the SDCS-MP-1 board

The power signal measurement board SDCS-MP-1is intended to be used as a service and rebuild(DCR 500 /DCR 600 commissioning) aid. Withoutthis board it is practically impossible to measurewith oscilloscope or with general purpose metersignals between the control board and the powerinterface board(s).

The board is plugged to the control board connec-tors X12, X13 and X17. The ribbon cables normallyconnected to the control board are connected tothe measurement board connectors having thesame name as the respective connector on thecontrol board.Measurement points for following signals are pro-vided:- the three phase to ground voltages UU, UV, UW

- the three phase to phase voltages UVU, UWV, UUW

- one rectified and filtered phase to phase voltageUAC

- armature voltage UDC with sign filtered- armature current IACT with sign- the six thyristor firing commands BZP1...BZP6- the two current direction commands SR1 and

SR2 (measurement points SR11 and SR21)- the sum of pulse transformer primary currents

can be measured across measurement pointsSR11-SR12 or SR21-SR22 depending on currentdirection

- the control board ground 0V.

The measurement points are separated from thecontrol board signals either with 10 kΩ resistors orwith operational amplifiers so that accidental shortcircuits between the measurement points do not af-fect the converter operation. Measurement point 0Vis directly connected to control board ground.

SDCS-MP-1X13:

X13:

X23

:

X12:

X12:

X22

:

X17:

X17:

X27

:

SDCS-CON-2

Measurement points

X12X13X17

X23

X22 X

27

SDCS-MP-1S

R11

BZ

P2

BZ

P3

BZ

P4

BZ

P5

BZ

P6

UW

VU

UW

UA

C

SR

12S

R21

SR

22IA

CT

0V

UV

U

BZ

P1

MP-1layout_b

Measurement points

Page 47: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-1

3ADW000165R0201_Technical_Data_e_b

The converter with a control board SDCS-CON-2can be connected in 4 different ways to a controlunit via analogue/digital links. Only one of the fourchoices can be used at the same time (Description

Analogue I/O´s:standardDigital I/O´s:not isolatedEncoder input:not isolated

Analogue I/O´s:standardDigital I/O´s:all isolated by means of op-tocoupler/relay, the signalstatus is indicated by LED

Analogue I/O´s:more input capacityDigital I/O´s:not isolatedencoder input:isolatedcurrent source for:PT100/PTC element

Analogue I/O´s:more input capacityDigital I/O´s:all isolated by means of op-tocoupler/relay, the signalstatus is indicated by LEDcurrent source for:PT100/PTC element

of the I/O's see chapter SDCS-CON-2). These pos-sibilities doesn't increase the number of inputs oroutputs. In addition to this an extension of I/O´s bySDCS-IOE-1 is possible, which increases thenumber of inputs.

Fig. 6/1 I/O via SDCS-CON-2 Fig. 6/2 I/O via SDCS-CON-2 and SDCS-IOB-2

Fig. 6/3 I/O via SDCS-CON-2 and SDCS-IOB-3 Fig. 6/4 I/O via SDCS-IOB-2 and SDCS-IOB-3

6 Digital and analogue I/O boards

X3: X4: X5: X6: X7:

X2: X1:

X17:

SDCS-CON-2

X3: X4: X5:

X2: X1:

X17:

SDCS-CON-2

X3: X1:

SDCS-IOB-2

X1: X2:

SDCS-IOB-3

X6: X7:

X2:

X17:

X1:

SDCS-CON-2

X2:

SDCS-IOB-3

X2:

X17:

SDCS-CON-2

X1:

SDCS-IOB-2

X1:

X1: X3:

Page 48: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-2

3ADW000165R0201_Technical_Data_e_b

6.1 Digital I/O board SDCS-IOB-2

As described at the beginning of the chapter, there arevarious options for configuring the inputs/outputs.

The board IOB-2x has 8 digital inputs and 8 digitaloutputs.There are three different types existing, which differ atthe input voltage level:

SDCS-IOB-21 24...48V DCSDCS-IOB-22 115 V ACSDCS-IOB-23 230 V AC

The inputs are filtered and galvanically isolated byusing optocouplers. Inputs can form two galvanicallyseparated groups by using either X7:1 or X7:2.

If these boards are in use, they have to be mountedoutside the DCS module. They must be mounted in away, that the conductive supports have a good con-nection to ground of the installation.

Fig. 6.1/1 I/O via SDCS-IOB-2x / IOB-3 and CON-2

Fig. 6.1/2 Layout and jumper settings of the SDCS-IOB-2x board

The cable length between X1:/X1: and X2:/X2: is max.1.7 m and between X1:/X3: is max. 0.5 m because ofEMC reasons.

X3: X4: X5:

X2: X1:

X17:

SDCS-CON-2

X3: X1:

SDCS-IOB-2

X2:

SDCS-IOB-3

X2:

X17:

SDCS-CON-2

X1:

SDCS-IOB-2

X1:

X1: X3:

S8

S7

R1

SDCS-IOB-2x

DI1

R2 R3 R4 R5 R6 R7 R8W1

3

W1

1

W9

W7

W5

W3

W1

W2

W4

W6

W8

W1

0

W1

2

W1

4

W1

5

W1

6

X6X5X4

X1X3

K1 K2 K3 K4 K5 K8

DI2 DI3 DI4 DI5 DI6 DI7 DI8

DO1 DO2 DO3DO4

DO5

DO6 DO7

DO8

1 1 1

X7

1

233.5

97.5

5

4

2ms

S7 *10ms

DI 7

S8 *DI 8

*

4 *

70

12

43

12

43

1

2 4

3

1

2 4

3

1

2 4

3

1

2 4

3

5

70

4

W10

0 **

time constant

Jumper coding

default value

input

supports are conductive

diameter of all supports: 4.3 mm

* this dimension may vary (4/5 mm) depending on revision

Line potential !

** W100 as printed circuit

iob2x1_c.dsf

Page 49: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-3

3ADW000165R0201_Technical_Data_e_b

Fig. 6.1/3 Terminal connection of the SDCS-IOB-2x board

Note:When the SDCS-CON-2 control board with the SDCS-IOB-2 I/O board is installed,terminals X6: and X7: on the SDCS-CON-2 must not be used.

Output value Signal definition Remarksby

K1...K5, K8 Software potential-isolated by relays(NO contact element)Contact ratings:AC: ≤250 V~/ ≤3 A~DC: ≤24 V-/ ≤3 A- or ≤115/230 V-/ ≤0.3 A-)MOV-protected (275 V)

K6,7 Software potential-isolated by optocouplerSwitching capacity: ≤50 mAexternal voltage: ≤24 V-

X4:, X5: are screw-clamp terminal types for leads up to 4 mm² cross-sectionalarea.Default values are shown within the software diagrams.The ground potential of the digital outputs may vary within ±100 V to each other.

Input value Signal definition Remarksby

Channel 1...8 potential-isolated by optocouplerIOB-21: (24...48V-) R1...R8 = 4.7 kΩ0...8 V = "0 signal"18...60 V = "1 signal"IOB-22: Software (115V~) R1...R8 = 22 kΩ0...20 V = "0 signal"60...130 V = "1 signal"IOB-23: (230 V~) R1...R8 = 47 kΩ0...40 V = "0 signal"90...250 V = "1 sig."

including tolerance; absolute maxvalues

X6: / X7: are screw-clamp terminal types for leads up to 4 mm² cross-sectionalareaInput resistance: see diagram.Input smoothing time constant: see diagram.Smoothing time constant of channel 7 and 8 can be changed; see fig. 6.1/2.The functionality of the input channels, which will be read, can be defined by soft-ware; default values are shown within the software diagramsPower supply for digital inputs: 48V / ≤ 50mA; not galv. isolated from the DCSelectronics!

If the inputs are supplied from the internal +48 V (X7:3 and/or X7:4) a connectionmust be done from either X7:1 and/or X7:2 to ground of the DCS 500 module. Indefault condition ground is identical to the converter's frame.

If the inputs are supplied by any external source (+48 V DC, 115 V AC or 230 VAC) the neutral line / - line must be connected to either X7:1 or X7:2. If the inputsshould be controlled with the same voltage level, but from two different voltagesources, having probably two different ground levels, the first neutral line shouldbe connected to X7:1 and the second to X7:2. In this case the jumpers Wx con-necting the inputs to X7:2, but controlled by the source, connected to X7:1, mustbe cut off.The same method is needed for the other jumpers Wx.

High frequency grounding is done by 100 nF capacitor.

X4:1

2

3

4

5

6

7

8

X5:1

DO1

DO2

DO3

DO4

DO5

DO6

DO7

DO8

2

3

4

5

6

7

8

K1

K2

K3

K4

K5

K8

DOx

66V

66V

DI2

DI4

DI5

DI6

DI7

DI8

3

5

6

8

2

4

W5 W6

W7 W8

W11 W12

X6:1

2

W1

R1

W3 W4

DI1

DI3

R2

R3

R44

R5

R6

W9 W10

R77

R8

W13 W14

W15 W16

X7:1

3

SDCS-IOB-2x Software

+48V

100n

681+

-681

DIx +

W2

W100

iob2x2_b.dsf

up to revision D from

revision E on

conductive support

Page 50: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-4

3ADW000165R0201_Technical_Data_e_b

6.2 Analogue I/O board SDCS-IOB-3

As described at the beginning of the chapter, there arevarious options for configuring the inputs/outputs.

The board SDCS-IOB-3 consists of the 5 analogueinputs, 3 analogue outputs, the galvanical isolatedpulse encoder interface and a current source fortemperature measuring devices.

If these boards are in use, they have to be mountedoutside the DCS module. They must be mounted in away, that the conductive supports have a good con-nection to ground of the installation.

The cable length between X1:/X1: and X2:/X2: is max.1.7 m and between X1:/X3: is max. 0.5 m because ofEMC reasons.

Fig. 6.2/2 Layout and jumper settings of the SDCS-IOB-3 board

Fig. 6.2/1 I/O via SDCS-IOB-2x / IOB-3 and CON-2

X1: X2:

SDCS-IOB-3

X6: X7:

X2:

X17:

X1:

SDCS-CON-2

X2:

SDCS-IOB-3

X2:

X17:

SDCS-CON-2

X1:

SDCS-IOB-2

X1:

X1: X3:

T1

X3 X4 X5

X1 X2

S2 S3

S1

S10

SDCS-IOB-3

AITACAI1

AI2

S1:1-2S1:3-4

S1:5-6S2

AI3 S1:7-8

Ch

AI4 S1:9-10

1 13

142

12

2223

S4

12

21

11

R110

S51 2

43

3 24

V17

1 1 112 1012

S1:11-12S1:13-14

PTC1.5 mA

PT1005 mA

*

12 V

S4

S5

S1S2S3

24 V 5 V *

*

**

***

*

**

85

233.5

5

4

70

S10*

*

S2

S3S3

5 V 12/24 V

5 V 12/24 V 13 mA

23

12324

22

23

12324

22

23

12324

22

23

12324

2223

12324

22

1

78

2 1

78

2

1357911

24681012

1357911

24681012

1357911

24681012

1 243

1 243

7531

8642

7531

8642

7531

8642

7531

8642

YES

YES

YES

4

5

70

gain = 1

-10V..+10V

gain = 10

-1V..+1V

Sum I ACnot equalto 0

activation of 500 Ω betweeninput terminal

Jumper coding

conductive supports

Characteristics for pulse encoder inputssingle ended:

differential:

Pulse encoder supply

Temperature sensor supply

Functionallity of analogue inputs

default value

iob3_c.dsf

Page 51: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-5

3ADW000165R0201_Technical_Data_e_b

Fig. 6.2/3 Terminal connection of the SDCS-IOB-3 board

Note:When the SDCS-CON-2 control board with the SDCS-IOB-3 I/O board isinstalled, the connection via plugs S4:1-2 and 3-4 on the SDCS-CON-2must be treated according to the diagram below:

Reso- Input/output Scaling Power Common Remarkslution values by mode[bit] Hardware range

12 + sign -10...0...+10 V Software ±20 V ➀ ➁ ➂ ➅

12 + sign -10...0...+10 V Software ±20 V ➀ ➁ ➂

11 + sign -10...0...+10 V Software ±40 V ➀ ➁ ➂ ➃ ➄

11 + sign -10...0...+10 V Software ±40 V ➀ ➁ ➂ ➃ ➄

11 + sign -10...0...+10 V Software ±40 V ➀ ➁ ➂➆

11 + sign -10...0...+10 V Software ≤5 * mA

11 + sign -10...0...+10 V Software ≤5 * mA

analogue -10...0...+10 V R 110 ≤5 * mA gain: 0.5...5

≤5 * mA for external use≤5 * mA e.g. reference pot.

1.5 mA Curr. source for PTC5 mA Curr. source for PT100

Encoder supply Remarks

Inputs isolated;Impedance = 120 Ω, if selectedmax. frequency ≤300 kHz

Sense lines for GND and supply to correct volt-age drops on cable (only if 5V/12V enc. is in use)

5V/ ≤0.25 A * Incremental encoder power supply12V/24V ≤0.2 A *

➆ Residual current detection is selected as default. The jumpers S1:11-12and S1:13-14 are set, inputs X3:9 and X3:10 and jumper S1:9-10 must not beused and inputs X3:11 and X3:12 serve as input for the current signal takenfrom a current transformer. This detection is based on a sum current trans-former where the secondary is connected through a diode bridge to 100 Ω re-sistor . Voltage will appear across the resistor, if the sum of the 3-phase cur-rent is not zero. In case AI4 should be used for a different purpose, use the in-puts/jumpers accordingly and take the block diagram as a help.

Restrictions using jumper S1, S2 or S3:The selection for the burden resistor across the input terminals can be done in-dependent from S2 or S3 settings for inputs AITAC, AI1, AI2, AI3 and AI4.If the gain is set to 10 by using S2 or S3 and the 500 Ω burden resistor is activat-ed, the input signal level is changed to -2 mA...0...+2 mA.For input AI4 there are the following configurations available:- input range ”20mA” , or- input range ”10V”, or- earth fault monitoring by Isum not equal to zero via X3:11 and X3:12

➀ total smoothing time ≤2 ms➁ -20...0...+20 mA by setting S1➂ 4...20 mA by ➁ + Software function➃ -1...0...-1 V by setting S2/S3 (CMR ±10 V)

-2...0...-2 mA by setting S2/S3 + S1 (CMR ±10 V)➄ designated for PT100 evaluation per software and hardware➅ If the input is used for tacho feedback and the tacho voltage

needs to be scaled, the board PS5311 must be ordered sepa-rate. If this input is used for feedback signals, there is a need foradditional margin for overshoot measurement. This margin is setby software and results e.g. in the 8 to 33 volts at PS5311.

* short circuit proof

X2:

+10V

0V

-10V

AO1

AITAC

AO2

+/- I-act

AI4

GND

0V

3 V = I NDC

100k1n1n

100k

100k 100k

Power-Source

Sense GND

Sense Power +

0V

AI2

AI1

-

+

-

+

-

+

-

+

500

S11 2

3 4

7 8

9 10

12 141311

100

S1

x

R1100V

0V

1.5 mA5 mA

1 2

3 4

S5

S4

V17

4

5

7

X5:12

3

6

8

9

10

3

4

5

6

7

8

9

10

X4:1

2

11

12

8

7

4

X3:1

2

3

6

5

9

10

11

12

SDCS-IOB-3 SoftwareSDCS-CON-x

+5 6

~

~

47.5100µ

100n

47.5100µ

100n

100µ

ChA +

ChA -

ChB +

ChB -

ChZ +

ChZ -

+24V 7 8 910 11 12

+24V 13141516 17 18

+24V4 5 6

S101 2 3S10

AI3

-x10

S2

S3

x10

PS5311

TG

+

- 81-270V

25-90V

8-33V

R9X2:3

X2:4

8

7

4

X1:1

2

3

6

5

6

X2:3

4

5

8

7

iob3x2_e.dsf

Terminals X3:, X4: and X5: on the SDCS-CON-2 must not be used.

S4 1 562

1 562

X3:2 (IOB-3) connectedto X3:2 on SDCS-CON-2and to GND

X3:2 (IOB-3) not connectedto X3:2 on SDCS-CON-2and not to GND

Page 52: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-6

3ADW000165R0201_Technical_Data_e_b

Fig. 6.2/4 Connections incremental encoder - electronics

0

65535

Forward

Connecting a pulse encoder to theDCS 500B / DCS 600 converterThe connection diagram for a pulse encoder to theelectronics of a DCS converter is quite similar, if theSDCS-CON-2 or the SDCS-IOB-3 is used. The basicdifference between these 2 boards is the galvanicalisolated circuit on the SDCS-IOB-3 board.

Power supply for incremental encoderThere is a galvanically isolated power supply for theincremental encoder on SDCS-IOB-3. The jumper S4on this board is used to select either +5 V, +12 V or+24 V as a supply voltage for the pulse encoder.When LED indicator (V17) is lit, the supply is OK.

The pulses generated by the pulse encoder aretransferred to the pulse receivers via opto couplers.

If the SDCS-CON-2 board is used the supply voltagefor the pulse encoder is selected on the SDCS-POW-1board (refer to SDCS-POW-1).

In both cases the voltage regulator has a feedbackcontrol with Sense power and Sense GND signals.

Feedback connection is recommended when powersupply level for differential pulse encoder is 5V. If a12 V pulse encoder type is in use the sense functionis also available. The wiring is shown on figure 6.2/4.

Fig. 6.2/5 TACHO_PULSES signal

A

A

B

B

Z

Z

+U

0V

X5:2

X5:1

X5:4

X5:3

X5:6

X5:5

IOB-3

X5:7

X5:10

X5:8

X5:9

GND

ChA+

ChA-

ChB+

ChB-

ChZ+

ChZ-

A

A

B

B

Z

Z

+U

0V

X5:2

X5:1

X5:4

X5:3

X5:6

X5:5

IOB-1/CON-2

X5:10

X5:7

X5:9

X5:8

X5:2

X5:1

X5:4

X5:3

X5:6

X5:5

X5:7

X5:10

X5:8

X5:9

GND

ChA+

ChA-

ChB+

ChB-

ChZ+

ChZ-

X5:2

X5:1

X5:4

X5:3

X5:6

X5:5

X5:10

X5:7

X5:9

X5:8

IOB-3 IOB-1/CON-2

= twisted pair

DIFFERENTIAL

SINGLE-ENDED

Power source

Sense power

Sense GND

Power source

Note:If the drive’s direction of rotation is correct (if nec-essary, correct by exchanging the field connec-tions), the Tacho error message may appear dur-ing start-up.

If with a positive reference the TACHO_PULSESsignal (with software 21.xxx: parameter 12104)does not look like the illustration below, then tracksA and A must be mutually exchanged with encod-ers with inverted signals, and tracks A and B withencoders without inverted signals.

If the TACHO_PULSES signal is missing or non-lin-ear, the encoder’s pulses are not being read cor-rectly. Possible reasons for this may be the encod-er supply, the encoder itself, or the wiring.

Page 53: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-7

3ADW000165R0201_Technical_Data_e_b

Incremental encoderTwo different incremental encoder connections areavailable.- differential connection; pulse encoders generating

either voltage or current signals can be used- single-ended (push pull) connection; voltage sig-

nals

Restrictions using jumper S1: or S10: dependingon the boardLine termination via S1/S10: 2-3 / 8-9 / 14-15 shouldnot be used at 12 V or 24 V encoders, because of thepower consumption taken from the encoder. If a pulseencoder with a build in current source is used aburden resistor of 120 Ω is activated via jumper S1/S10: 1-2 a.s.o.

Fig. 6.2/6 Pulse encoder connection principles

If a single ended 12 V / 24 V encoder is used S1/S10should be set to 5-6 / 11-12 / 17-18 according to thelayouts of the boards. This setting results in an internalthreshold of appr. 5 V.

In case of a single ended 5 V encoder the jumpers will beset to a neutral position S1/S10: 4-5 / 10-11 / 16-17. To geta threshold lower than 5 V each terminal X5:2 / X5:4 /X5:6 must be connected via a resistor R to GND accord-ing to the table below.

R 1 kΩ 1.5 Ω 2.2 kΩ U thresh 1.2 V 1.8 V 2.3 V

Make sure the threshold is half of the supply voltage andthe minimum voltage of the encoder output (saturationvoltage UCE of a transistor).

Three differential inputs are reserved for connecting thepulse encoder. CH A and CH B are the normal pulsechannels having nominal 90° phase shift between thechannels.

The channel CH A- (CH B-) is the inversed channel CH A(CH B). CH Z is the zero pulse channel which can beadditionally used if the encoder has an output giving one“zero” pulse per revolution.

The distance between pulse encoder and interface boardis dependent on the voltage drop on the connecting linesand on the output and input configuration of the usedcomponents. If cables are used according to the nexttable the voltage drop caused by the cable can becorrected by the voltage regulator.

Cable length parallel wires for Cable usedpower source & GND

0 ... 50 m 1x 0.25 mm² 12x 0.25 mm²50 ... 100 m 2x 0.25 mm² 12x 0.25 mm²

100 ... 150 m 3x 0.25 mm² 14x 0.25 mm²

CH+

CH-

SDCS-IOB-1/CON-2 / IOB-3

+

+

+24V

X5:1

X5:2

S1:(S10)

SDCS-IOB-1/CON-2 / IOB-3

+

+

+24V

X5:1

X5:2

S1:(S10)

SDCS-IOB-1/CON-2 / IOB-3

+

+

+24V

X5:1

X5:2

S1:(S10) 1

2

3

45

6

-U

+U

GND

R

R

iob14_e.dsf

1

2

3

45

6

12

3

45

6

120

10k

120

10k

120

10k

GND

Page 54: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-8

3ADW000165R0201_Technical_Data_e_b

6.3 Extension board SDCS-IOE-1

The board consists of:7 isolated digital inputs2 analogue inputs1 current source for the supply of PTC or PT 100elements

The board is connected electrically via a 10 pin flatcable to the converter module electronics. The con-nection will be done to the SDCS-CON-2 boardfrom terminal row X17 to X17 on SDCS-IOE-1. Ithas to be mounted outside of the converter module.The cable length is 2 m because of EMC reasons.

Mechanical ConstructionThe board is mounted on a plastic housing whichhas foot elements (Phoenix Contact series UMK).The foot elements permit snap-in assembly to astandard DIN EN rail (EN 50022, 50035).The dimensions are including the plastic housing.

Fig. 6.3/2 Layout and jumper settings of the SDCS-IOE-1 board

X17:

SDCS-IOE-1 X3: X4: X5: X6: X7:

X2: X1:

X17:

SDCS-CON-2

4 x

anal

og1

x T

acho

7 x

digi

tal

8 x

digi

tal

2 x

anal

og

Pul

sgeb

er

Fig. 6.3/1 Connection of the SDCS-IOE-1 board andthe SDCS-CON-2 board.

SDCS-IOE-1X17

1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10

X2S1 S2 S4S3

H1 H2 H3 H4 H5 H6 H7

* * * *

AI5

AI6

S1:3-4

S2:3-4S3

ChPTC1.5 mA

PT1005 mA

*

S4S1S2S3

***

S3

1 243

1 243

2468

1357

8

21

71 2

431 2

431 2

43

S2:1-2

S1:1-2

2468

1357

146.3

90

X1

3 81 4

ioe1_c.dsf

gain = 1

-10V..+10V

gain = 10

-1V..+1V

Jumperparking

activation of 500 Ω betweeninput terminal

Jumper coding

Temperature sensor supplyFunctionallity of analogue inputs

default value

Pla

stic

hou

sing

Mou

ntin

g fo

r D

IN-r

ail

YES

Page 55: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-9

3ADW000165R0201_Technical_Data_e_b

Fig. 6.3/3 Terminal connection of the SDCS-IOE-1 board

Input value Signal definition Remarksby

0...8 V Software = "0" status16...31 V = "1" status

Two potential isolatedgroups. Max. operatingvoltage between thegroups and the controlboard is 50 V

Filter time constant for allinputs is 2.2 ms

Reso- Input/output Scaling Power Common Remarkslution values by mode[bit] Hardware range

11 + sign -10...0...+10 V Software ±40 V ➀ ➁ ➂

11 + sign -10...0...+10 V Software ±40 V ➀ ➁ ➂ ➃

1.5 mA Curr. source for PTC5 mA Curr. source for PT100

absolute accuracy in-cluding the controlboard is 0.7%

➀ total smoothing time ≤2 ms➁ -20...0...+20 mA by setting S1/S2➂ 4...20 mA by ➁ + Software function➃ -1...0...-1 V by setting S3 (CMR ±10 V)

-2...0...-2 mA by setting S3 + S2 (CMR ±10 V)

SDCS-IOE-1 SoftwareSDCS-CON-2

DI10

DI12

DI13

DI14

DI15

3

5

6

8

X1:1

2

DI9

DI11

4

7

2.2k

47n

2.2k

681

H1 +

10

9

GND

AI5

100k

1n1n

100k

100k 100k

AI6

-

+

-

+

500

S13 4

3 4x10

S3

8

7

4

X2:1

2

3

6

5

9

10

S2

1.5 mA5 mA

3 4

S4100µ

0V

0V

1 2

ioe1x1_e.dsf

for cable shields

for cable shields

for cable shields

Page 56: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 6-10

3ADW000165R0201_Technical_Data_e_b

Page 57: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 7-1

3ADW000165R0201_Technical_Data_e_b

cannot be used together with software versionS21.xxx.Channel 3 is a DDCS channel of up to 4 Mbits/sand is used if a serial link based on PROFIBUShardware, CS31 hardware or MODBUS hardwareshould be realized. If one of these possibilitiesshould be used an adaptation module is needed.This channel can only be used with software ver-sion S21.1xx (SDCS_CON-1). Please refer to thedocumentation which is available for the link sys-tem needed.

Fig. 7.1/1 Connection between SDCS-COM-x and a partner

Fig. 7.1/2 Layout and jumper settings of the SDCS-COM-5 board

This board is used for communications toDCS 500B converter modules equipped with soft-ware 21.xxx for commissioning and maintenancepurposes. It consists of 3 different communicationchannels. All RxD channels (receiver) have bluecolor, all TxD channels (transmitter) have greycolor. If any connections should be made alwaysconnect the same color with each other (plug andsocket) .Channel 1 is a HDLC channel of 1.5 Mbits/s and isused for the communication with a PC. Channel 2

RxD

TxD

SDCS-COM-x

blueblue

blueblue

grey grey

grey grey

Partner

V3

V4

V1

V2

V5

V6

D8

D11

S1

SDCS-COM-5X11

CH 3RxD

TxD

CH 1RxD

TxD

CH 2RxD

TxD

D7

S1

S1

S1

S1

1

2

3

4

*

156.5

83.5

13 *2

4

13 *2

4

13

24

13

24

132

4

Coding forchannel 2

Converter number

Jumper coding

default value

conductive support

7 Communication boards7.1 Communication board SDCS-COM-5

Page 58: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 7-2

3ADW000165R0201_Technical_Data_e_b

Fig. 7.2/1 Layout of the SDCS-AMC-DC / SDCS-AMC-DC Classic board / AMC-DC Drive Bus

This board must be used together with a DCS 600module equipped with a SDCS-CON-2 board in-cluding software S15.xxx.

The board is equipped with an own controller withthe following main functionalities:• The software structure implemented in this board

is divided in two sections. The first section is builtfrom the speed regulator and its additional func-tions which is producing the torque reference.

• The second section is prepared to be pro-grammed with its own characteristics for controland regulation.

• Evaluation of the received data to produce atorque reference to be transmitted to the control-ler board CON-2. Actual values from the CON-2

7.2 Control and communication board SDCS-AMC-DC

are read, evaluated and retransmitted to theoverriding control.

Furthermore the board is equipped with three opti-cal channels (max. data transmission speed is 4Mb for each optical channel):- Channel 0 is used to communicate data from the

overriding control (FCI, APC2, AC80, Nxxx-xx(adapter modules for fieldbus), AC800M) or viaadapter modules from other controllers) to theDCS600-drive.

- Channel 2 (Master-Follower) is used to operatetwo or more drives dependent on each other.Commands and values needed for this applica-tion are produced on this board.

- Channel 3 is prepared to connect the PC tool forcommissioning and maintenance (DriveWindow).

Remark: Only channels with the same compo-nents (e.g. 10 Mb component) may beconnected to each other.

optical Components Channel 0 used for D400 driver current Communication **Ch 0 Ch 2 Ch 3 CH0, CH2, CH3 CH0

SDCS-AMC-DC * 10 Mb 5 Mb 10 Mb other interfaces ICMC1 30 mA DDCS

SDCS-AMC-DC Classic * 5 Mb 10 Mb 10 Mb Fieldbus adapter modules Nxxx-xx ICMC1 30 mA DDCS

SDCS-AMC-DC 2 10 Mb 5 Mb 10 Mb other interfaces ICMC2 30/50 mA *** DDCS/Drive Bus

SDCS-AMC-DC Classic 2 5 Mb 10 Mb 10 Mb Fieldbus adapter modules Nxxx-xx ICMC2 30/50 mA *** DDCS/Drive Bus

* SDCS-AMC-DC 2, SDCS-AMC-DC Classic 2 are direct replacements of SDCS-AMC-DC and SDCS-AMC-DC Classic** see additional parameter [71.01]

Color of optical components:*** 5 Mb ⇒ blue maximum 30 mA*** 10 Mb⇒ dark grey maximum 50 mA

The SDCS-AMC-DC and the SDCS-AMC-DC Clas-sic boards are identical except the assembly of opticalcomponents for channel 0 and 2.

D200

SDCS-AMC-DCX10

CH 3TxD

RxD

CH 2TxD

RxD

CH 0TxD

RxD

D105

156.5

83.5

D400

D100

conductive support

grey

grey

grey

darkgrey

5V o.k.

Prg. runningFault

green

red

green

dark grey

blue

dark grey

blue

Page 59: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 7-3

3ADW000165R0201_Technical_Data_e_b

Fig. 7.2/2 Connections at Master-Follower mode

Fig. 7.2/3 Module Bus connections to Advant controllers (ring)

Fig. 7.2/4 Drive Bus connections to Advant Controller 80 (star)

For more configuration possibilitiessee publication 3AFE 63988235

10 m - AMC-DC / DC 2

20 m - AMC-DC Classic

D20

0

X10

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D10

5

D40

0

D20

0

X10

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D10

5

D40

0

D20

0

X10

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D10

5

D40

0

10 m - AMC-DC / DC 2

20 m - AMC-DC Classic / Classic 2

amc_1_1_e.dsf

plastic optic fibre

or A

MC

-DC

2S

DC

S-A

MC

-DC

or A

MC

-DC

2S

DC

S-A

MC

-DC

or A

MC

-DC

2S

DC

S-A

MC

-DC

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

FCIAC80

TxD

RxD

. . .

TB 810

20 m - AMC-DC

30 m - AMC-DC 2

amc_1_1_e.dsf

or A

MC

-DC

2

or A

MC

-DC

2

or A

MC

-DC

2

plastic optic fibre

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

. . .

20 m SDCS-AMC-DC30 m SDCS-AMC-DC 2

TxD

RxD

TxD

RxD

TxD

RxD

NDBU-950, 1, 2 ... ...8

TxD

RxD

. . .

AC80

TxD

RxD

Ch0 Drive Bus

amc_1_1_d.dsf

or A

MC

-DC

2

or A

MC

-DC

2

or A

MC

-DC

2

plastic optic fibre

30 m plastic optic fibre

Page 60: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 7-4

3ADW000165R0201_Technical_Data_e_b

Fig. 7.2/5 Connections to higher-level system (APC)

Fig. 7.2/6 Connections to higher-level system (Communication modules)

Fig. 7.2/7 Connections to PC by ring (with control program DriveWindow)

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

YPQ112 B

TxD

RxD

TxD

RxD

TxD

RxD

TxD

RxD

APC

. . .

20 m

amc_1_1_e.dsf

or A

MC

-DC

2

or A

MC

-DC

2

or A

MC

-DC

2

plastic optic fibre

Nxxx-xxNxxx-xx

TxD

RxD

D20

0

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

SD

CS

-AM

C-D

C C

lass

ic

D20

0

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

SD

CS

-AM

C-D

C C

lass

ic

D20

0

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

SD

CS

-AM

C-D

C C

lass

ic

TxD

RxD

Nxxx-xx

TxD

RxD

. . .

. . .

10 m

amc_1_1_d.dsf

Fieldbus

or A

MC

-DC

Cla

ssic

2

or A

MC

-DC

Cla

ssic

2

or A

MC

-DC

Cla

ssic

2

plastic optic fibre

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

TxD

RxD

. . .

20 m SDCS-AMC-DC / AMC-DC Classic30 m SDCS-AMC DC 2 / AMC-DC Classic 2

NISA-03 (PC)NDPC-12NDPA-02

amc_1_1_d.dsf

or A

MC

-DC

2or

AM

C-D

C C

lass

icor

AM

C-D

C C

lass

ic 2

or A

MC

-DC

2or

AM

C-D

C C

lass

icor

AM

C-D

C C

lass

ic 2

or A

MC

-DC

2or

AM

C-D

C C

lass

icor

AM

C-D

C C

lass

ic 2

plastic optic fibre

(Laptop)

Page 61: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 7-5

3ADW000165R0201_Technical_Data_e_b

Fig. 7.2/8 Connections to PC by star (with control program DriveWindow)

For more configuration possibilitiessee publication 3ADW 000100R0201

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

D20

0

SD

CS

-AM

C-D

C

CH

3T

xD

RxD

CH

2T

xD

RxD

CH

0T

xD

RxD

D40

0

TxD

RxD

TxD

RxD

TxD

RxD

. . .

NDBU-950, 1, 2 ... ...8

TxD

RxD

. . .

TxD

RxD

TxD

RxD

TxD

RxD

TxD

RxD

TxD

RxD

TxD

RxD

. . .

. . .

TxD

RxD

TxD

RxD

20 mSDCS-AMC-DCSDCS-AMC-DC Classic

30 mSDCS-AMC-DC 2SDCS-AMC-DC Classic 2

max. 30 m

. . .NDBU-950, 1, 2 ... ...8

NDBU-950, 1, 2 ... ...8

(Laptop)

NISA-03 (PC)NDPC-12NDPA-02

HCSSilicat

max. 200 m

amc_1_1_d.dsf

Plasticopt. fibre

Branchingunit

Branchingunit

Plastic opt. fibre

Branchingunit

Plasticopt. fibre

PC

boa

rd

or A

MC

-DC

2or

AM

C-D

C C

lass

icor

AM

C-D

C C

lass

ic 2

or A

MC

-DC

2or

AM

C-D

C C

lass

icor

AM

C-D

C C

lass

ic 2

or A

MC

-DC

2or

AM

C-D

C C

lass

icor

AM

C-D

C C

lass

ic 2

max. 30 m

or 200 m HCS

Page 62: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 7-6

3ADW000165R0201_Technical_Data_e_b

DDCS Branching Unit (DBU) is used (only for DCS600/DCF 600) to implement the star topology ofDDCS link. This allows a slave unit to fail or becomeunpowered without disabling the communication. TheNDBU receives messages from the master (PC) andsends them to all the slave units simultaneously. Eachslave unit has an individual address and only theaddressed slave unit sends a reply message to themaster. It is also possible to use NDBU thus enablingpeer-to-peer communication.

7.3 DDCS Branching unit NDBU-95

NDBU-95 DDCS Branching Unit has nine outputchannels where messages from the master are sent.The reply message sent by one slave unit is deliveredto the master and it can be delivered also to otherslaves if necessary. Several NDBU-95s can be usedin parallel, in series or in any combination of these.The maximum distance between the master andNDBU-95 as well as between two NDBU-95s, seemanual 3ADW000100R0201.

Technical specifications

Optical links:Master channels 1 DDCS input and 1 DDCS out-

putSlave channels 9 DDCS inputs and 9 DDCS

outputsData rate 1 - 4 MBd, programmable

Driving current 20 mA, 30 mA, 50 mA + chan-nel disabling, programmable

Monitoring a green LED for each channel,switched on when NDBU is re-ceiving messages

Transmission device 10 Mb component for eachchannel

Power supply:Input voltage +24 VDC ± 10%Input current 300 mAMonitoring a green LED switched on when

the output voltage is normal

Operating temperature: +0 ... +50 °CPCB dimensions: s. diagram beside

For further information see Appendix D in theDriveWindow User's Manual.

Fig. 7.3/1 Layout of the NDBU-95 branching unit

NoteFor addressing and automatic node numbering ofthe drives and branching units see DriveWindowdocumentaion.

264

V120

V119

V118

V117

V116

V115

V114

V113

V112

V111

V110

V109

V108

V107

V106

V105

V104

V103

V102

V101

X1

8

1

CH8

CH7

CH6

CH5

CH4

CH3

CH2

CH1

RXD

MSTR

24 V DC

S1

NDBU-95DDCS BRANCHING UNIT, 8+1 CH

CH0

12 0 V

TXD

RXD

TXD

RXD

TXD

RXD

TXD

RXD

TXD

RXD

TXD

RXD

TXD

RXD

TXD

TXD

RXD

TXD

RXD

+5V OK

X2-X11

TRANSMSETTING

DISLONG

MEDIUMSHORT

1 0

ADDRESS

++

++

++

++

X12++

++

++

++

1 2 4

MBIT/S

41

94

DBU

Remark: Only channels with the same compo-nents (e.g. 10 Mb component) may beconnected to each other.

Page 63: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-1

3ADW000165R0201_Technical_Data_e_b

8 Field exciters

8.1 SDCS-FEX-1 (internal)The Diode Field Exciter board SDCS-FEX-1 is asingle phase diode rectifier for an AC input voltageup to 500 V and a DC output current of 6 A. Theboard has to be mounted inside the armature con-verter module. The excitation current is defined bythe DC output voltage (line voltage multiplied by0.9) and the resistance of the field winding. By us-ing an external resistor in series with the field wind-ing the field current can be adapted slightly.If the SDCS-FEX-1 board isn't already installed itmust be mechanically fixed beside the electronicpower part SDCS-POW-1 and connected via a flatcable to the SDCS-CON-2 by using terminal X14.

8.1.1 Electrical data of FEX-1

AC input voltage: 110 V -15%...500 V +10%max. DC output current: 6 A; IF rated

DC output curr. monitoring: 20 mA...6 APower loss at IF rated : ≤10 WAC Isolating voltage: 600 VTerminals X1:Cross sectional area 2,5 mm²

Fig. 8.1/3 Output voltage with inductive or resistiveload - High-signal at X14:B3

Fig. 8.1/2 Diode field exciter with field loss monitor-ing

Fig. 8.1/1 Layout of the SDCS-FEX-1 field exciterboard

The DCS 500 system has different options for thefield supply. There are one and three phase fieldexciters available, which can be either integrated(diode field exciter SDCS-FEX-1 and half controlledfield exciter SDCS-FEX-2A) or externally mounted(half controlled DCF503-0050 with the SDCS-FEX-32 board and fully controlled DCF504-0050 with theSDCS-FEX-31 board).

Three phase field exciters DCF 50xB/60x are con-verter modules themselves, similar to the DCS501B/601 or DCS 502B/602 additionally a overvolt-age protection unit is needed see chapter 8.4.

The AC share of the output DC voltage is meas-ured with a capacitor and an auxiliary rectifier andused for current monitoring.Transistor relay is closed when the DC current isflowing (>0.02 A).

Fig. 8.1/4 Output voltage without loadLow-signal at X14:B3

X1:X14:

V1

-

+

SDCS-FEX-1

1

5

3

7

F-

F+ 80

130

Fixed isolating supports (15 mm)

linepotential !

S DC S -FE X -1

X1: 3

F+ F-

5

X1: 1 7SDCS-CON-x

X14:9

3

+ -X14:A4

B3

+ 15 V

CONVERTER MODULE

t

U

U

t

Page 64: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-2

3ADW000165R0201_Technical_Data_e_b

The field exciter board SDCS-FEX-2 / FEX-2A con-sists of a power part and a control board, whichconnects all components electrically and mechani-cally to each other. This arrangement has to bemounted inside the armature converter module be-side the electronic power supply SDCS-POW-1.This is intended to be done for DCS modules oftype C1, C2 and A5, not for A6 and A7 (C4)!

The power part is build up with two power modules.Each of the modules consists of one diode and onethyristor, so they are wired up and controlled like ahalf controlled bridge.

Fig. 8.2/1 Layout of the SDCS-FEX-2A field exciter board

8.2.1 Electrical data of SDCS-FEX-2 / FEX-2AAC input voltage: 110 V -15%...500 V +10%; single phaseAC input current: ≤ output currentAC isolation voltage: 600 VFrequency: same as DCS converter moduleDC output current: ➀ 0.3 A...8 A for armature converter module from 25 A to 75 A

0.3 A...16 A for armature converter mod. from 100 A to 2000 APower loss at IF rated : ≤40 WOutput IACT: Uout = 4 V *Iact / Ilim; Ilim = 3A, 5A, 7A, 9A, 11A, 13A, 15A, 17ATerminal X1:Cross sectional area 4 mm²

➀ If Field weakening is needed, actual field current of the motor at top speed must behigher than 0.3 A

The control is based on a fully digital system. Theµ-processor reads all information from the powerpart, is supplied with all needed voltage levels andcontrol signals via the flat cable X14 by the SDCS-CON-2 and generates the firing pulses for the pow-er part.

The range of the single phase rated AC input volt-age is 110 V to 500 V, the maximum current capa-bility is 16 A. If this field exciter is used for smallerfield current, the control unit automatically selects alower current range between 3 A to 16 A to get thebest resolution.

8.2 SDCS-FEX-2 / SDCS-FEX-2A (internal)

1

5

10

6

V11

V13

X1:

X14:T11

T13

T1X20

D37

SDCS-FEX-21 8

1

5

3

7

F-

F+

IACTGND

90

240

Conductive supportFixed isolating supports (15 mm)

linepotential !

Page 65: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-3

3ADW000165R0201_Technical_Data_e_b

8.2.2 Control unitThe control unit includes the following main blocks:

- Micro controller 80C198 for controlling and firing- Actual DC current measurement with an AC

current transformer.- RS485 interface to the converter's controller

board SDCS-CON-x.

The software for the field current control is stored inthe ROM memory of the 80C198. The control isdone by using a PI structure for the current control-ler. All parameters needed for the control or forscaling reasons (selection of burden resistors) arestored in the non-volatile memory of the armatureconverter and transferred to the field controller dur-ing each initializing process via the RS485 link.The Node number is always fix coded to Nodenumber = 1.

The output Iact represents the actual field current,which is measured via the AC transformer, thenrectified and transferred into a voltage signal withburden resistors. The burden resistors, as men-tioned before, are adapted by the board itself de-pending on the setting of the nominal field currentof the motor (see list before). The resulting burdenvoltage can be measured at test terminals besideX14:. The 2.2 KΩ resistor allows a short circuit atthe terminals; the external measuring device shouldhave an internal resistance higher than 1MΩ.

The terminal row X20: is used for test purposes.

8.2.3 Power sectionTwo diode-thyristor modules are arranged as ahalf-controlled single-phase rectifier. The anodes ofthe two diodes are not connected directly to eachother as usual; they are now connected to the endsof the four turn primary winding of the current trans-former. The center tap is the negative output of therectifier. Thus it is possible to measure the DC cur-rent with an AC current transformer.

A MOV (Metal Oxide Varistor) protects the AC inputagainst voltage spikes from the external source.Another MOV protects the DC output against volt-age surges which can be caused by the field wind-ing of a DC machine.

Fig. 8.2/2 Block diagram of the field exciter SDCS-FEX-2A

Synchronisation

T1

2k2

burden adjustment

AC Input DC Output

Power supply voltages+48V, +15V, -15V, +5V, 0V

Control unit

from SDC S-CON-xvia X14:

RS 485Serial link

Page 66: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-4

3ADW000165R0201_Technical_Data_e_b

The half controlled (2-Q) field exciter unit DCF503A-0050 consists of the SDCS-FEX-32A board, twothyristor/diode power modules and auxiliaries (powersupply, line choke). The full controlled (4-Q) fieldexciter unit DCF504A-0050 consists of the SDCS-FEX-31A board, four anti-parallel thyristor/ thyristor

Fig. 8.3/2 Layout of the DCF504A-0050 field exciter unit

Fig. 8.3 /1 Different versions of power section of the DCF50xA-0050

power modules and the same auxiliaries.The control is structured similar to the SDCS-FEX-2Afield supply. A micro controller is used for controllingand firing. The DC current is measured by using anAC current transformer (same configuration than atSDCS-FEX-2A).

8.3 DCF503A-0050 and DCF504A-0050 (external)

8.3.1 Electrical data of DCF50xA-0050Power partAC input voltage: 110 V -15%...500 V +10%; single phaseAC input current: ≤ output currentFrequency: same as DCS converter moduleAC isolation voltage: 690 VLine reactor: 160 µH; 45-65 HzDC output current: ➀ 0.3...50 APower loss at IF rated : ≤180 WLoad condition always L/R > 100 ms (saturation)Auxiliary voltage (X3:1-2)AC input voltage: 110 V -15%...230 V +10%; single phaseFrequency: 45 ... 65 HzAC input power: 15 W; 30 VAInrush current: <5 A / 20 msMains buffering: min 30 msTerminal row X2:X2: 1 RS 485 serial link to X16: 1 at SDCS-CON-1 / CON-2X2: 2 RS 485 serial link to X16: 2 at SDCS-CON-1 / CON-2X2: 3 Ground B grounded via cable screen and / or grounded via S2X2: 4 not usedX2: 5 not used

➀ If Field weakening is needed, actual field current of the motor at top speed must be higher than 0.3 A

T1 T1

+

-

+

-

DCF504A DCF503A

Fex3x1_d.dsf

ACsupply

DCoutput

ACsupply

DCoutput

C1 (+)

D1 (-)

U1

1

5

X6

X2

1

5

V11, V12

V21, V22 V23, V24

V13, V14

X111 X112 X113 X114

X121 X122 X123 X1241

X70

7

X501

1

X208

X5

SDCS-FEX-31ASDCS-FEX-32A

X12 X11

V1

275

330

S11 342

S21 3

42

69

1X800

10LED

1 2X3

6

T1

GNDBarea

S2: 1-3 *S2: 1-2 S2: 3-4

S1: 1-2 S1: 3-4 *

X101

X100

Fex3A_b.dsf

Commutationchoke

Conductive supports

Isolating supports

Linepotential !

1

23456789

10

Node no. 1 serial link CON-2

not used

Field exciter modeBridge reversal time:4 cyclesSerial link to CON-1, CON-2

Node no. 2 serial link CON-2

not used

Test modeextended; Bridgereversal timeNot used - don't select

Setting X800 Switch OFF * ON

* Default value for all switchesThe settings are read during initialization.

GNDB isolatedGNDB grounded via RC circuitGNDB direct grounded

Jumper CodingGrounding of RS485 Transmission driver

* Default value

Firmware downloadField exciter mode

CPU mode

Page 67: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-5

3ADW000165R0201_Technical_Data_e_b

8.3.2 Electronic power supplyThere is a power supply unit on the board. Supplyis connected at terminal X3. The rated AC voltages115 V and 230 V can be applied without any modifi-cation.The power supply unit provides the DC voltages 30V, 15 V, 5 V and -15 V to the control electronics.Voltages can be measured by means of a multime-ter from the terminal X70 (see the layout).In addition the power supply generates 5 V for gal-vanic isolated RS485 communication drivers. Thisvoltages can be measured at terminals X100/X101.

Measured Terminal Ground voltage positive

+5V X70:1 X70:2 (GND)+30V X70:3 X70:5 (GND)+15V X70:4 X70:5 (GND)-15V X70:6 X70:5 (GND)+ 5V X100 X101:1 (GNDB)

8.3.3 Control unitThe control unit includes the following main blocks:- Micro controller H8 for control and firing- Actual DC current measurement with an AC

current transformer.- RS485 interface to the converter's controller

board SDCS-CON-x.

The software for the field current control is stored inthe FlashPROM memory. This software contains a

PI current controllerFault/reset logicSynchronization and PLL functionBridge reversal function (only DCF 504A)

The setting and updating of all control parametersare set from armature converter via RS485 inter-face. Actual current, field current reference, controland status bit are cyclic sent via RS 485 communi-cation.

The field exciter is equipped with an auto-scalingfunction of burden resistor based on the nominalfield current of the motor.

The output Iact represents the actual field current,which is measured via the AC transformer, thenrectified and transferred into a voltage signal withburden resistors. The burden resistors -scaled tomeasurement range- are adapted by the board it-self depending on the setting of the nominal motorfield current. The current signal can be measuredUCursig at X20:3-X70:2 and is scaled to

4 V *Iact / IScale

IScale = 3A, 5A, 7A, 9A, 11A, 13A, 15A, 17A, 21A,27A, 33A, 39A, 45A, 51A

8.3.4 Power sectionIf a DCF503A-0050 is in use two diode-thyristormodules are arranged as a half-controlled single-phase rectifier. If a DCS504A-0050 is in use fourthyristor-thyristor modules are arranged as a full-controlled single-phase rectifier. The anodes of thetwo diodes (anodes / cathodes of the thyristors) arenot connected directly to each other as usual; theyare connected to the ends of the primary winding ofthe current transformer. The centre tap is the nega-tive output of the rectifier. Thus it is possible tomeasure the DC current with an AC current trans-former.

A MOV (Metal Oxide Varistor) protects the AC inputagainst voltage spikes from the external source.Another MOV protects the DC output against volt-age surges which can be caused by the field wind-ing of a DC machine. The free wheeling functionneeded e.g. during network failure is ”build in” be-cause of the diodes, if the half-controlled version isin use. If the full-controlled version is used the freewheeling function is realized by using the thyristorsin diode mode, triggered by a fast voltage rise.

8.3.5 RS232-PortThe RS232 interface is used for download the'Field exciter firmware package'.

The default settings of this interface are as follows:

Signal level: RS232 (+12V / -12V)Data format: UARTMessage format: Modbus-ProtocolTransmission method: half-duplexBaudrate: 9.600 BaudNumber of Data bits: 8Number of Stop bits: 1Parity-Bit: odd

The programming procedure is activated by settingS1:1-2 during auxiliary voltage is switched ON. Set-ting for field exciter mode is S1:3-4 (default).

1

9

5

6

X6: Description

1 not connected2 TxD3 RxD4 not connected5 SGND Signal ground6...9 not connected

Fig. 8.3/3 Pin assignment of RS232-Port

Page 68: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-6

3ADW000165R0201_Technical_Data_e_b

Fig. 8.3/6 Serial communication cable connection

Fig. 8.3/5 Serial communication cable connection and address setting for Node 1and field exciter Node 2, using SDCS-FEX-2A and DCF50xA-0050

8.3.6 Field exciter configurationsThe data exchange between- SDCS-CON-2 and- field exciter SDCS-FEX-2A or- DCF503A/504A-0050 or- DCFx01/x02 (three-phase field exciter)is done via a RS485 serial link, which can be con-figured as a bus structure. This link is used totransfer references, actual values and settings forup to two field exciter units.

The drive software located on the SDCS-CON-2board consists of two field supply functions, firstfield exciter and second field exciter. The first fieldexciter is already connected to the EMF controllerto control the motor in all points of the motor dia-gram. The second field exciter is accessible via thefield current reference.

The RS485 interface works with a screened two-wire cable. The allowed length is 5 m. The wireshave to be connected to the terminals X2:1 andX2:2 and the screen to X2:3.

Typical application of this kind is two DC motorsconnected to one converter. The load sharing canbe done by means of adjusting the excitation cur-rent of the second DC-motor.

There are two possible configurations for two Nodenumbers of the field exciters:- one SDCS-FEX-2A and one external field excit-

er (DCF503A-0050, DCF504A-0050 or 3-phasefield exciter) or

- two external field exciter units (DCF503A-0050,DCF504A-0050 or 3-phase field exciter).

If a SDCS-FEX-2A is used, it will be always recog-nized as the field exciter Node 1 by the software.Node 1 or Node 2 must be coded according to thetable below for DCF503A/504A-0050 and for the 3-phase field exciters (via parameter). The scan timefor Node 1 = 10 ms, for Node 2 = 100 ms. Fieldweakening is not necessarily available for Node 2.

Fig. 8.3/4 Typical application example with two fieldexciter units and one converter (withoutfield weakening).

Procedure for field exciter Node changing of theDCF 503A/504A:• Switch off the units voltage supply• Set the appropriate switch according to the table• Initialization through switch on the electronics sup-

ply voltage

Field exciter Node 1 Field exciter Node 2

Unit type Setting X800 Unit type Setting X800

SDCS-FEX-2A --- --- ---DCF 503A/504A X800:1 = OFF --- ---SDCS-FEX-2A --- DCF 503A/504A X800:1 = ONDCF 503A/504A X800:1 = OFF DCF 503A/504A X800:1 = ON

M M

D C F503A-0050

D C F503A-0050

SD C S-C O N-2

1 . 2 .

2exec_1cv_b.dsf

U1

V1

C1

D1

PE

X2:1X2:2X2:3

X3:2

X16:1X16:2X16:3

DCF503A-0050

SDCS-CON-2

X3:1

X14

SDCS-FEX-2A

X14

Fex3Ax2_c.dsf

AC INPUT

DC OUTPUT

Power supply

Total lengthmax 5 m

Armaturecontroller

FieldexciterNode 2

field exciter Node 1

Node 2X800:1=ON

X2:1X2:2X2:3

X3:2

X16:1X16:2X16:3

DCF503A-0050

SDCS-CON-2

X3:1

X2:1X2:2X2:3

X3:2

DCF503A-0050

X3:1

U1

V1

C1

D1

PE

U1

V1

C1

D1

PE

Fex3Ax3_b.dsf

AC INPUT

DC OUTPUT

Power supply

Total lengthmax 5 m

Armaturecontroller

AC INPUT

DC OUTPUT

Power supply

Total lengthmax 5 m Field

exciterNode 2

FieldexciterNode 1

Node 1X800:1=OFF

Node 2X800:1=ON

Page 69: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-7

3ADW000165R0201_Technical_Data_e_b

FAULT

Definition

8 Boot sequence failed or Flash PROM empty F81 Auxiliary voltage below 90 V F82 Hardware fault F83 Software fault F84 Par flash read fault

e.g. checksum wrong F85 Compatibility fault

Software or typecode not compatible to parameters F86 Typecode read fault

Checksum failure during typecode check F88 Mains voltage smaller 40 VAC F89 Mains voltage higher 620 VAC F90 Mains sync. fault

e.g. f < 40 Hz, f > 70 Hz F91 Field current above 125% of selected current measurement range F92 Fast voltage rise

see parameters: DCS600: [P44.04 / P44.10] DCS500B: [P13.10 / P13.07]

ALARMS

Definition

A81 Parameters added A88 Up / Download failed A90 Compatibility Alarm A91 Parameter restored

8.3.7 DiagnosisThe armature converter receivesvia serial link the sum of all faultsin "Fex status bit". A more detailederror code is given on the sevensegment display of DCF 503A/DCF 504A.All faults are reset with the nextON command given to the arma-ture current controller.

Fig. 8.3/7 DCF503A/DCF504A-0050 converter diagram

Parts not mounted at DCF 503A-0050* V12/V14 are diodes at DCF503A

*SDCS-FEX-31ASDCS-FEX-32A

DCF503_4_conv_diagr.dsf

X3: 2 1

AC1

U1PE V1

AC2

1

2 3

4

D1 C1

X2:

(+)(-)

1

2

345

Page 70: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-8

3ADW000165R0201_Technical_Data_e_b

External field exciterDCF 503A-0050DCF 504A-0050

Dimensions in mmWeight appr. 10 kg

8.3.8 Dimensions

Fig. 8.3/8 Dimension drawing of DCF 503/4A

U1

V1

C1

D1

U1

V1

C1 (+)

D1 (-)

1

9 5

6

X80

0

M6

173

3x41

=123

M6

X6

X2

X800

LED

Sub-D

1

10

X2:

Sig

nal t

erm

inal

sS

eria

l lin

k

X3:

Aux

. pow

er s

uppl

y te

rmin

als

all for M6

all for M6

all f

or M

6

Direction of air flow

Min

imum

Top

clea

ranc

e

all for M6

Min

imum

Bot

tom

cle

aran

ce

all for M6

Mou

ntin

g di

rect

ion

Signal terminalsSerial link(aux. voltages)

Aux. power supply terminals

A

A

Note: In case of vibrating environments use fixing holes A

Page 71: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-9

3ADW000165R0201_Technical_Data_e_b

The three-phase field supply converter DCF 501B/502B and DCF 601/602 need a separate active Over-voltage Protection unit DCF 505 or DCF 506 to protectthe power part against inadmissibly high voltages.

The protection unit activates a free-wheeling circuitbetween the F+ and F- connectors if an overvoltageoccurs. The DCF 505/506 consists of a trigger unit

8.4 DCF505 / DCF506 Overvoltage Protection

(SDCS-FEP-x) and a free-wheeling thyristor (two inanti-parallel at DCF 506).

The DCF 506 consist of a relay output to indicate afree-wheeling condition to the field supply converter.When the free-wheeling function is triggered, it willlast until the DC current is less than appr. 0.5 A. Duringthis time the relay contacts are closed.

Fig. 8.4/1: Simple load with DCF 501B/601 and 2-QOvervoltage Protection DCF 505

Fig. 8.4/2: Motor field supply with DCS 50xB/DCF 60xand 4-Q Overvoltage Protection DCF 506

Assignment Field supply converter to Overvol-tage protection unit

Field supply converter Overvoltage Protectionfor motor fields

2-Q, 500 VDCF501B/601-0025-51DCF501B/601-0050-51 DCF506-0140-51DCF501B/601-0075-51DCF501B/601-0100-51

DCF501B/601-0200-51DCF501B/601-0350-51 DCF506-0520-51DCF501B/601-0450-51DCF501B/601-0520-51

4-Q, 500VDCF502B/602-0025-51DCF502B/602-0050-51 DCF506-0140-51DCF502B/602-0075-51DCF502B/602-0100-51

DCF502B/602-0200-51DCF502B/602-0350-51 DCF506-0520-51DCF502B/602-0450-51DCF502B/602-0520-51

Inductive load supply Overvoltage Protectionfor other applications

4-Q, 500VDCS502B/602-1200-51 DCF506-1200-51DCS502B/602-1500-51 DCF506-1500-51

4-Q, 690VDCS502B/602-0900-71 DCF506-1500-71DCS502B/602-1500-71

Table 8.4/1: Assignment converter to Overvoltage Pro-tection unit

For motor field supply via DCF 501/601 (2-Q) orDCF 502B/602 (4-Q) the overvoltage protection unitDCF 506 is always required.

The overvoltage protection unit DCF 505 is suitablefor 2-Q converters DCF 501B/601 with simple non-motoric inductive load.

DCF 501BDCF 601

C1(+)

D1(-)

DCF 505X11

X12

Field supply Converter

Overvoltageprotection

MDCF 501B/502BDCF 601/602

DCF 506

X6:2 9X4:1 2

C1(+)

D1(-)

X11

X12

Field supply Converter

Overvoltageprotection

Page 72: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-10

3ADW000165R0201_Technical_Data_e_b

Diagram

Fig. 8.4/3: Overvoltage Protection DCF 505 / DCF 506

X3

X4X2

X1

line potential !

SD

CS

-FE

P-1

/FE

P-2

Fep1_2.dsf

Fig. 8.4/4: Layout of SDCS-FEP-1/FEP-2

There are two trigger units in use:- SDCS-FEP-1 for systems, used at line voltages

up to 500 V; this board is equipped with a 1400 Vtrigger diode.

- SDCS-FEP-2 for systems, used at line voltagesup to 690 V; this board is equipped with a 1800 Vtrigger diode.

Output X4:1-2Potential isolated by relay (NO contact)Contacts no protectedContact rating: AC: ≤60 V~/ ≤50 mA~

DC: ≤60V-/ ≤50 mA-

F-

A1

X2:3

X1:1

G1

A

K1

X2:2

X1:3

X2:1

G2 K2

X3:1

X3:2

X4:1 X4:2

KR3

F+

X11 X12

1 2AK

1 2

1 2

1 2R1

R4

R2

V1

X1:2

SDCS-FEP-1 (500 V)SDCS-FEP-2 (690 V)

DCF505di_d.dsf

parts not built-in at 2-Q unit, R3 jumpered

red

grey

red

grey

Page 73: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-11

3ADW000165R0201_Technical_Data_e_b

Overvoltage ProtectionDCF 505-0140/0520-51DCF 505-1200-51DCF 506-0140/0520-51

Dimensions in mmWeight appr. 8 kg

Dimensions

Overvoltage ProtectionDCF 506-1200-51DCF 506-1500-51DCF 506-1500-71

Dimensions in mmWeight appr. 20 kg

X41

X11 (F+)

X12 (F-)

12

16 75 33.59

350

11 7

342

M8

MB_520_a.dsf

X3 X1

X4 X212

SDCS-FEP-1 (500 V)SDCS-FEP-2 (690 V)

MB_1500_a.dsf

42 145

8.5

355

145

f. M6M84032

35 8.5

482

20 135

X11

X12

Page 74: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 8-12

3ADW000165R0201_Technical_Data_e_b

Page 75: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-1

3ADW000165R0201_Technical_Data_e_b

Type Resistance [mΩΩΩΩΩ] Fuse F1 Size Fuse holder170M 1558 30 10A 660V UR 0 OFAX 00 S3L170M 1559 21 21A 660V UR 0 OFAX 00 S3L170M 1561 15 25A 660V UR 0 OFAX 00 S3L170M 1564 6 50A 660V UR 0 OFAX 00 S3L170M 1565 4 63A 660V UR 0 OFAX 00 S3L170M 1566 3 80A 660V UR 0 OFAX 00 S3L170M 1568 1,.8 125A 660V UR 0 OFAX 00 S3L170M 3815 0,.87 200A 660V UR 1 OFAX 1 S3170M 3816 0,.59 250A 600V UR 1 OFAX 1 S3170M 3817 0,.47 315A 660V UR 1 OFAX 1 S3170M 3819 0,.37 400A 660V UR 1 OFAX 1 S3170M 5810 0,.3 500A 660V UR 2 OFAX 2 S3170M 6811 0,.22 700A 660V UR 3 OFAX 3 S3170M 6163 0,.15 900A 660V UR * 170H 3006170M 6166 0,.09 1250A 660V UR * 170H 3006170M 6811 0,.22 700A 660V UR 3 OFAS B 3170M 6813 0,.15 900A 660V UR 3 OFAS B 3

Table 9.1/1: Fuses and fuse holders

9.1.1 Fuses and fuse holders (Converter size C1, C2)

9 Accessories9.1 Accessories - Power circuit

Main dimensions of fuse holders

Fuse HxWxD Protectionholder [mm]

OFAX 00 S3L 148x112x111 IP20OFAX 1 S3 250x174x123 IP20OFAX 2 S3 250x214x133 IP20OFAX 3 S3 265x246x160 IP20OFAS B 3 250x246x136 IP00

Table 9.1/2: Fuse holders

Fig. 9.1/2: Fuse holder OFAX ... Fig. 9.1/3: Fuse holder OFAS B 3

Dimensions [mm] Size 0...3

Size a b c d e0 78,5 50 35 21 151 135 69 45 45 202 150 69 55 55 263 150 68 76 76 33

Remark:Given dimensions may be exeeded in some cases.Please take them only for information.

Fig. 9.1/1: Fuses size 0...3

L1 L2 L3

F1

OFASB 3

W D

H

W D

H

Fig. 9.1/4: Fuse holder 170H 3006

* drawing see chapter 2.2

a

d e

210

c

6

b

Fuse1_a.dsf

Indicator

M10

110

A

A

M8

27

205

180

64 77

M8

A-A

6085

Ø 9

M10

40

170H3006_a.dsf

will become obsolete; new assign-ment of fuse holder and fuse

Page 76: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-2

3ADW000165R0201_Technical_Data_e_b

Type Choke rated Weight Power loss recommendedL Irms Ipeak Voltage Fe Cu for armature

[µH] [A] [A] [UN] [kg] [W] [W] converter type

ND 01 512 18 27 500 2.0 5 16 DCS...-0025ND 02 250 37 68 500 3.0 7 22 DCS...-0050ND 03 300 37 68 600 3.8 9 20 DCS...-0050ND 04 168 55 82 500 5.8 10 33 DCS...-0075ND 05 135 82 122 600 6.4 5 30 DCS...-0110ND 06 90 102 153 500 7.6 7 41 DCS...-0140ND 07 50 184 275 500 12.6 45 90 DCS...-0250ND 08 56.3 196 294 600 12.8 45 130 DCS...-0270ND 09 37.5 245 367 500 16.0 50 140 DCS...-0350ND 10 25.0 367 551 500 22.2 80 185 DCS...-0520ND 11 33.8 326 490 600 22.6 80 185 DCS...-0450ND 12 18.8 490 734 500 36.0 95 290 DCS...-0820 (2-Q)ND 13 18.2 698 1047 690 46.8 170 160 DCS...-0820 (4-Q)ND 14 9.9 930 1395 500 46.6 100 300 DCS...-1200ND 15 10.9 1163 1744 690 84.0 190 680 DCS...-1500ND 16 6.1 1510 2264 500 81.2 210 650 DCS...-2000

Line chokes type ND 01...ND 16

Table 9.1/3: Data of line chokes

Type a1 a b c d e f gmm²

ND 01 120 100 130 48 65 116 4 8 6ND 02 120 100 130 58 65 116 4 8 10ND 03 148 125 157 63 80 143 5 10 10ND 04 148 125 157 78 80 143 5 10 16ND 05 148 125 157 78 80 143 5 10 25ND 06 178 150 180 72 90 170 5 10 35

Line chokes type ND 01...ND 06

to mains

to converter

9.1.2 Line chokes

Fig. 9.1/4: Line choke type ND 01...ND 06

Line chokes for use in industrial environment (minimum requirements), low inductive voltage drop, deepcommutation notches.Line chokes ND01...ND06 are equipped with cables. The bigger ones ND07...ND16 are equipped with bus-bars. When connecting them to other components, please take relevant standards into account in case thematerials are different. Don't use choke terminals as cable or busbar support!

A, B, C 600 1000

X, Y, Z

baa1

c

A

X

B

Y

C

Z

A

B

C

X

Y

Z

3

A, B, C

X, Y, Z

d

e

g

f

ND1_to_6_a.dsf

Page 77: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-3

3ADW000165R0201_Technical_Data_e_b

Type A B C C1 E F G H I K L busbarND 07, 08 285 230 86 100 250 176 65 80 9x18 385 232 20x4ND 09 327 250 99 100 292 224 63 100 9x18 423 280 30x5ND 10, 11 408 250 99 100 374 224 63 100 11x18 504 280 60x6ND 12 458 250 112 113 424 224 63 100 13x18 554 280 40x6

Line chokes type ND 07...ND 12

Line chokes type ND 15, 16all busbars 60x10

Line chokes type ND 13, 14all busbars 40x10

Fig. 9.1/5: Line chokes type ND 07...ND 12

Fig. 9.1/6: Line chokes type ND 13, ND 14 Fig. 9.1/7: Line chokes type ND 15, ND 16

C ±1

B ±1F ±0.3

H ±2

15

3AST 478223 D5

3AFE 100146030.0188 mH

490 A

I max 734 A

15K

I (6x

)

G ±

4A

±2

E ±

2

A-A

E±2

7

±0.3F

A

A

C1L

ND7_to_12_c.dsf

min

30

∅ w

ithou

t var

nish

for

cond

uctio

n to

the

mou

ntin

g p

late

A A

A-A

18x1

3(3x

)

100

±2140

45 45

±415

4±2

342

±2150 40

50

±2123

10

±1290

100

30

±0.3

224

15

40

ø13

ND13_14_c.dsf

min

30

∅ w

ithou

t var

nish

for

cond

uctio

n to

the

mou

ntin

g p

late

(6x)

10x

18

±2151

45

90

±517

6±2

440

±2181

147 48

15

80

40ø

13

30140

±1390

14030

20

A A

A-A

147 13

±0.3

316

18

15

60

ø13

ND15_16_c.dsf

30min

30

∅ w

ithou

t var

nish

for

cond

uctio

n to

the

mou

ntin

g p

late

Page 78: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-4

3ADW000165R0201_Technical_Data_e_b

Table 9.1/4: Data of line chokes type ND4

Line chokes type ND 401...ND 402

Fig. 9.1/8: Line choke type ND 401...ND 402

Table 9.1/5: Dimensions of line chokes type ND 401...ND 402

Type Choke rated Weight Power loss Load LoadL Irms Ipeak Voltage Fe Cu DC curr. 1 DC curr.2

[µH] Line AC [A] [A] [UN] [kg] [W] [W] (f. Usupply=400V)(f. Usupply=500V)

ND 401 1000 18.5 27 400 3.5 13 35 22.6 18ND 402 600 37 68 400 7.5 13 50 45 36ND 403 450 55 82 400 11 42 90 67 54ND 404 350 74 111 400 13 78 105 90 72ND 405 250 104 156 400 19 91 105 127 101ND 406 160 148 220 400 22 104 130 179 143ND 407 120 192 288 400 23 117 130 234 187ND 408 90 252 387 400 29 137 160 315 252ND 409 70 332 498 400 33 170 215 405 324ND 410 60 406 609 400 51 260 225 495 396ND 411 50 502 753 400 56 260 300 612 490ND 412 40 605 805 400 62 280 335 738 590ND 413 35 740 1105 400 75 312 410 900 720

Type A B C D E F Ø G Ø HND 401 160 190 75 80 51 175 7 9ND 402 200 220 105 115 75 200 7 9

Line chokes type ND 401...ND 413Line chokes for use in light industrial/residential environment, high inductivevoltage drop, reduced commutation notches.

These chokes are designed for drives which usually operate in speed control modeat 400 V or 500 V networks. Because of that a duty cycle has been taken intoaccount. The percentage taken into account for that duty cycle is different for 400V and 500 V networks:- for Urated supply = 400 V, DC curr. 1 ≈ 90% of nominal current- for Urated supply = 500 V, DC curr. 1 ≈ 72% of nominal current

For easier reading the maximum average DC load current is listed instead of thepercentage in the next table.

Line chokes ND401...ND402 are equipped with terminals. The bigger onesND403...ND413 are equipped with busbars. When connecting them to othercomponents, please take relevant standards into account in case the materialsare different.

A X B Y C Z170

D

B

F±1ø G+5

E ±2

C

ZYX

BA C

Terminals: WAGO Type 202 UL File E45172

ø H

A

ø G

tin-coated

Page 79: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-5

3ADW000165R0201_Technical_Data_e_b

Fig. 9.1/9: Line choke type ND 403...ND 408

Fig. 9.1/10: Line choke type ND 409...ND 413

Line chokes type ND 403...ND 408

Line chokes type ND 409...ND 413

Type A B C D E F Ø G Ø H Ø KND 403 220 230 120 135 100 77.5 7 9 6.6ND 404 220 225 120 140 100 77.5 7 9 6.6ND 405 235 250 155 170 125 85 10 9 6.6ND 406 255 275 155 175 125 95 10 9 9ND 407 255 275 155 175 125 95 10 9 11ND 408 285 285 180 210 150 95 10 9 11

Type A B C D E F Ø G Ø H Ø KND 409 320 280 180 210 150 95 10 11 11ND 410 345 350 180 235 150 115 10 13 14ND 411 345 350 205 270 175 115 12 13 2x11ND 412 385 350 205 280 175 115 12 13 2x11ND 413 445 350 205 280 175 115 12 13 2x11

B

A

F ±2

104550

ø Htin-coated

E ±2

C

D

ø G+5

A

X

B

Y

C

Z

øK AL

B

A

F ±212

ø Htin-coated

øG+6

E ±2C

D

A

X

B

Y

C

Z

A B C

X Y Z

øK AL

Page 80: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-6

3ADW000165R0201_Technical_Data_e_b

9.2 Accessories - Field

Type for Field curr. Transformer's Weight Power loss Fuse F3secondary current

IF Isec [kg] PV [W] [A]Uprim = 500 V; 50/60Hz

T 3.01 ≤6 A ≤7 A 15 65 10T 3.02 ≤12 A ≤13 A 20 100 16T 3.03 ≤16 A ≤17 A 20 120 25T 3.04 ≤30 A ≤33 A 36 180 50T 3.05 ≤50 A ≤57 A 60 250 63

Uprim = 690 V; 50/60HzT 3.11 ≤6 A ≤7 A ➀ 15 80 10T 3.12 ≤12 A ≤13 A ➀ 20 125 16T 3.13 ≤16 A ≤17 A ➀ 30 150 20T 3.14 ≤30 A ≤33 A 60 230 50T 3.15 ≤50 A ≤57 A 60 320 63

➀ 690 V transformer input cannot be used for the field converters SDCS-FEX-1 and SDCS-FEX-2 (isolation only 600 V max.)

Table 9.2/1: Autotransformer data

9.2.1 Autotransformer T3

9.2.2 Line choke L3 for SDCS-FEX-2

F 3

T 3

Type A B C D h e GT 3.01 / T 3.11 210 110 112 75 240 10x18 95T 3.02 / T 3.12 210 135 112 101 240 10x18 95T 3.03T 3.13 230 150 124 118 270 10x18 95T 3.04 260 150 144 123 330 10x18 95T 3.14 295 175 176 141 380 12x18 95T 3.05 / T 3.15

F 3

T 3

Fig. 9.2/1: Autotransformer T3

4.5 Ø

2

max

70

max 80

37

52

1000

1 3 4

1

3

2

4

55

Fig. 9.2/2: Line choke L3

Type line choke data L3 Weight PowerL Irms Ipeak loss

[µH] [A] [A] [kg] [W] [mm²]

ND30 2x >500 16 16 1,1 8 2

Table 9.2/2: Data of line choke for field exciter

Page 81: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-7

3ADW000165R0201_Technical_Data_e_b

9.3 Fan, electronics

Type Power Weight Fuse F2 Isec Power loss[VA] [kg] [A] [A] [W]

T2 1400 15 16 6 (0...230 V) 10012 (0...115 V)

Table 9.3/1: Data supply transformer T2

Input voltage: 230/380...690 V/1~; ±10%Frequency: 50...60 HzOutput voltage: 115/230 V/1~

9.3.1 Supply transformer T2 for electronics and fan

Fig. 9.3/1: Dimensions Transformer T2

The supply transformer T2 has been re-designed. The new power and current rating allows to supply then2-phase fans and the electronics by one transformer only in case A5 converters are used in a 12-pulseconfiguration.They differ in their electrical data and therefore can be identified by their name plate.

Type Power Weight Fuse F2 Power loss[VA] [kg] [A] [W]

T2 460 13 6 20

Table 9.3/2: Data supply transformer T2

F2

T2

0 V115 V230 V T2_a.dsf

Application hint:

F2

T2

0 V115 V230 V T2_a.dsf

230 V

The transformer is designed to work as a 230 V /230 V transformer to open/avoid ground loops. This isdone via the 380 V and 600 V taping according to theleft picture.

Transformer data T2 used in the past:

150

106

125

128

148

100 +-5

35

0 115

230 0 380

400

415

450

500

525

575

600

660

690

6.3 mm Faston

T2_dim.dsf

Page 82: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-8

3ADW000165R0201_Technical_Data_e_b

9.4 Residual current detection

9.4.1 Residual current detectionThe converters DCS500B and DCS600 together withthe board SDCS-IOB-3 and a specially designedcurrent transformer (CT), big enough to feed throughall the cables / busbars of the three phases arealready prepared to detect residual current. Thisoption can only be used at grounded networks.

AttentionThis detection cannot be used to protect persons oranimals against electrical shock!

Normally the current taken from the network, passing

the converter on one phase, then going to the motorwill leave the converter on a different phase andending in the network. A current sample taken fromdifferent phases always will show the same amount,but a different sign at two phases and no current at thethird. With all three phases feed through one currenttransformer, the magnetic field around each conduc-tor will compensate each other in case the currenttakes the path intended and the signal measured atthe signal terminals of the current transformer will bezero.

This relationship can be described by this formula:Σ Σ Σ Σ Σ (IL1 + IL2 + IL3) = 0

In case the current takes any path different to the oneroughly described above the current entering theconverter at one phase will be different to the oneleaving the converter at another phase. The magneticfield will not compensate which results in a currentsignal given by the CT and which is equivalent to thecurrent missing. Any current caused for example bystray capacitance (Cp) is measured and may need tobe treated separate. This signal is read by the circuit

on the SDCS-IOB-3 board and then calculated by theconverter´s firmware to be available for further use.

A drive system normally consists of several groups ofconsumers. As long as the supply for consumer(s) istaken from the three phases feed through the CT allthese consumers are monitored. This is the way tomonitor either only the motor´s armature circuit, orarmature and field or the complete drive with all theauxillary circuits like motor fan or other consumers.

9.4.2 Electrical and mechanical dataThere are 2 different current transformers available.They basically differ by their physical dimensions.Consumers connected via cables will have a lowercurrent and therefore monitored most often by thesmaller CT, specified for 1500 A. Bigger consumersor even several drives monitored as a group andsupplied via busbars use the bigger one, specified forcurrents up to around 3300 A. Finally the crosssectional area available for the conductors for thethree-phases is the criteria to use the one or the othertype. Furthermore, the CTs can replace each otherelectrically, the value for the nominal load currentshould be taken as a suggestion and the overallaccuracy becomes better, if the current of the load isclose to the current capability of the CT.

When doing the final mechanical work, please try tomake sure the conductors are placed symmetricallywithin the available cross sectional area.

The current transformer has got no burden resistorbuild in. The CT output has to be connected to theSDCS-IOB-3 board via a shielded twisted pair cablemaximum 2 m long. The circuit the CT´s output signalis connected to, consists of a diode bridge for rectifi-cation, a burden resistor to change the signal tovoltage level and some elements for protection. Final-ly the signal equivalent of the difference in current isread by Analog Input 4. For more details, see Soft-ware Description.

PWS 10004 PWS 33001Insulation voltage ≤ 1000 V ≤ 1500 VLoad current ≤ 1500 A appr. 1200 A…3300 AAmbient temperat. -25° ... +70 °CRatio 400 : 1

Fig. 9.4/1: Dimensions of current transformer type PWS 10004

Cp

M

Iact

I L1

I L2

I L3

residual_curr_detect.dsf

Current transformer type PWS 10004 (I ≤ 1500A)

273

223

25

84,5

25

25

33

M4*8S1 S2P2

P1

89

±0,5

40

40

30

PWS10004_dim.dsf

30 30

no busbars are allowedwithin 30 (40) mm around the CT

CT

Page 83: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-9

3ADW000165R0201_Technical_Data_e_b

Current transformer type PWS 33001 (I ≤ 3300A)

9.4.3 Mechanical fixingThese current transformers don´t have fixings attached to them. There are holders available for the smalland the bigger one. Because of the CT´s construction a left and a right one is necessary per CT.

Current transformer type PWS 10004 (I ≤ 1500A)

Current transformer type PWS 33001 (I ≤ 3300A)

HintsAfter having all parts installed, please make sure:- jumper S1 on SDCS-IOB-3 is in position 11 - 12 and 13 - 14

no cables connected to terminals X3:9 and X3:10 at SDCS-IOB-3 board- select AI4 for this monitoring function by parameter

activate that monitoring function via parameterdefine the threshold in amps via parameterif necessary delay the error message via parameter to avoid actions caused by disturbance or similar

left holder

right holder

290

18

drilling pattern(free space)

CT

holes for M6

left holder

right holder

CT

46869

.

drilling pattern(free space)

holes for M6

Fig. 9.4/2: Dimensions of current transformer type PWS 33001

Fig. 9.4/3: Fixing of current transformer type PWS 10004

Fig. 9.4/5: Fixing of current transformer type PWS 33001

Fig. 9.4/4: Drilling pattern of current transformer type PWS 10004

Fig. 9.4/6: Drilling pattern of current transformer type PWS 33001

30

30

450

340

55

190

55

5555

50

M4*8S1 S2

P2P1

198max

PWS33001_dim.dsf

30

30 30

no busbars are allowedwithin 30 mm around the CT

CT

Page 84: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-10

3ADW000165R0201_Technical_Data_e_b

9.5 EMC Filters

9.5.1 Three-phase filtersEMC filters are necessary to fulfil EN 50081 if aconverter shall be run at a public low voltage line,in Europe for example with 400 V between thephases. Such lines have an earthed neutral con-ductor. ABB offers suitable three - phase filters for400 V and 25 A...600 A and 500 V filters for 440 Vlines outside Europe. Lines with 500 V to 1000 Vare not public. They are local lines inside factories,and they do not supply sensitive electronics. There-fore converters do not need EMC filters if they shallrun with 500 V and more.

Filter type max. voltage

IN Terminals for wires with max. dimension

Weight PE con-necti-

on [V] [A] [mm²] * [kg]

NF3-440-25 440 25 4 3.0 M6 NF3-440-50 440 50 10/16 3.1 M6 NF3-440-64 440 64 10/16 3.1 M6 NF3-440-80 440 80 25/35 9.5 M10 NF3-440-110 440 110 50 9.5 M10 NF3-500-25 500 25 4 3.0 M6 NF3-500-50 500 50 10/16 3.1 M6 NF3-500-64 500 64 10/16 3.1 M6 NF3-500-80 500 80 25/35 9.5 M10 NF3-500-110 500 110 50 9.5 M10 NF3-500-320 500 320 Bar with

11mm hole 21.0 M10

NF3-500-600 500 600 Bar with 11mm hole

22.0 M10

NF3-690-600 690 600 Bar with

11mm hole 22.0 M10

NF3-690-1000 690 1000 Bar with 14 mm hole

28 M12

NF3-690-1600 690 1600 Bar with 2x 14 mm hole

34 M12

NF3-690-2500 690 2500 Bar with 4x 14 mm hole

105 M16

* single core / litz wire

Table. 9.5/1: Electrical ratings of three-phase filters

Page 85: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-11

3ADW000165R0201_Technical_Data_e_b

LOAD

LIN

E

17250

200

115

120

150

136

65

2019

.25

20

6.4

Screws for earthing M6

Fig. 9.5/1: Dimensions of three-phase filters NF3-xxx-25, 50, 64

LIN

E

LOAD

15x6.517

0

90400

350

373

130

Screws for earthing M10

Fig. 9.5/2: Dimensions of three-phase filters NF3-xxx-80, 110

Page 86: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-12

3ADW000165R0201_Technical_Data_e_b

Fig. 9.5/3: Dimensions of three-phase filters NF3-xxx-320

Fig. 9.5/4: Dimensions of three-phase filters NF3-xxx-600

300(60) (60)

Line

5

Load

L1L2

L3

L1L2

L3

240 ±1

235

±1

260

40 ±140 ±1∅ 12

∅ 11 M10 x 30

360±715 15

25

120 30

180

±0.5

210

35

90

85 ±0.5

11515

1

350(60) (60)

Line

5

Load

L1L2

L3

L1L2

L3290 ±1

235

±1

260

40 ±1.540 ±1.5∅ 12

∅ 11 M10 x 30

410±2.515 15

30

120 30

180

±0.5

210

35

90

85 ±0.5

11515

1

Page 87: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-13

3ADW000165R0201_Technical_Data_e_b

Fig. 9.5/5: Dimensions of three-phase filters NF3-xxx-1000

Fig. 9.5/6: Dimensions of three-phase filters NF3-xxx-1600

Fig. 9.5/7: Dimensions of three-phase filters NF3-xxx-2500

Page 88: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-14

3ADW000165R0201_Technical_Data_e_b

9.5.2 Single-phase filtersMany field supply units are single - phase convert-ers for up to 50 A excitation current. They can besupplied by two of the three input phases of the ar-mature supply converter. Then a field supply unitdoes not need its own filter. If the phase voltage tothe neutral conductor shall be taken (230 V in a400 V line) then a separate single-phase filter isnecessary. ABB offers such filters for 250 V and6...55 A.

Table 9.5/2: Electrical ratings of single-phase filters

Filter type max. voltage

IN Terminals for wires with max. dimension

Weight PE con-necti-

on [V] [A] [mm²] * [kg]

NF1-250-8 250 8 4 0.7 M6 NF1-250-12 250 12 4 0.9 M6 NF1-250-20 250 20 4 1.0 M6 NF1-250-30 250 30 10/16 1.0 M6 NF1-250-55 250 55 10/16 1.8 M6 * single core / litz wire

LIN

E

LOA

D

51

99.5

95

105

84.5

57

4.46

1018

16

138.5

Screws for earthing M6

Fig. 9.5/8: Dimensions of single-phase filters NF1-xxx-8, 12, 20

Page 89: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-15

3ADW000165R0201_Technical_Data_e_b

Screws for earthing M6

LIN

E

LOAD

51

99.5

148

95

105

84.520

1619

57

4.46

Fig. 9.5/9: Dimensions of single-phase filters NF1-xxx-30

Fig. 9.5/10: Dimensions of single-phase filters NF1-xxx-55

LOA

D

LIN

E

231

20

115

6.4

100

115

180

85

60

17

13

Screws for earthing M6

Page 90: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-16

3ADW000165R0201_Technical_Data_e_b

Further Explanation of FiltersOverload Capacity

Magnetic Limit Currents (Surge Current)

Filter Type Maximum Surge Current IDCmax (average)

NF3-xxx-25 80 A NF3-xxx-50 130 A NF3-xxx-64 170 A NF3-xxx-80 160 A NF3-xxx-110 220 A NF3-xxx-320 600 A NF3-xxx-600 1200 A

Thermal Limit Current

The thermal time constant of the converter is smaller than the thermal time con-stant of the filter, if the filter is chosen according to the tables in appendix A.

In particular cases (e.g. a special load diagram as shown in the figure below the required filter current can be calculated with the following equation:

)...(182.0 22

221

21).( nnratedefffilter tItItI

TI ⋅++⋅+⋅⋅⋅≥ .

IDC

I1

I2

I3

I4

I1

t1 t2 t4T

t3t

Example of load diagram

Environmental Conditions

Ambient operating temperature: 0…+40 °C

Derating: above 40 °C same derating as for the converter Storage temperature: -25…+80 °C

Cooling method: natural air cooling

Page 91: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-17

3ADW000165R0201_Technical_Data_e_b

Appendix AOptical cables

For the bus communication of the DCS convertersthere are different optical cables available.

Kind of cable Connector cable length Ident. no. Fig.

plastic fibre optic single cable plug 0.5...20 m 3ADT 693324 1plastic fibre optic double cable plug 0.5...20 m 3ADT 693318 2HCS silica (double) without plastic jacket plug 30...50 m 3ADT 693355 3HCS silica (double) with plastic jacket plug 50...200 m 3ADT 693356 4Glass fibre optic (double) reinforced FSMA 10...100 m 3ADV 300002 5

blue

black

black

blue

L

blue black L

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

for D

CS

400

DC

S 50

0D

CS

600

for D

CS

600

sele

cted

cha

nnel

s.se

e m

anua

l ND

BU

3A

DW

000

100

R02

01fo

r DC

S 50

0 +

YPC

115

L

orange

black

orange

black∅ 5 mm

L

blue

red

blue

red∅ 8 mm

L

green

red

green

red

III A-1

Page 92: DCS Thyristor Power Converters for DC drive systemsdrivetech.com.ve/papeleria/manuales/DT_EN_DCS500_TD.pdf · The term “DCS thyristor power converter” is a general designation

III 9-18

3ADW000165R0201_Technical_Data_e_b

Since we aim to always meet the latest state-of-the-art standards with our products, we are sure youwill understand when we reserve the right to alterparticulars of design, figures, sizes, weights, etc. forour equipment as specified in this brochure.

3AD

W 0

00 1

65 R

0201

RE

V B

03_2

005

ABB Automation Products GmbHPostfach 118068619 Lampertheim • GERMANYTelefon +49(0) 62 06 5 03-0Telefax +49(0) 62 06 5 03-6 09www.abb.com/dc

*165R0201A5090000**165R0201A5090000*

DCS 400

DCS 500B / DCS 600

DCS 400 / DCS 500Easy Drive

DCA 500 / DCA 600

DCE 500 / DCE 600

The drive module for standard applications Integrated field supply (max. 20 A) Accurate speed and torque control Extremely small and compact design Very easy installation and commissioning Express delivery Power range: 10...500 kW (13...670 HP)

The drive module for demandingapplications Free programming of software 6- and 12-pulse configuration up to 10 MW/

13,000 HP and more Plain text display Power range: 10...5000 kW (13...6700 HP)

Highly integrated panel Excellent upgrade or revamp solution Contains:

DCS 500B / DCS 600 module AC fuses Auxiliary transformer Motor fan starter with protection Main contactor

Power range: 10...130 kW (26...300 HP)

The complete standard cabinet solution Pre-engineered Easy installation and commissioning Protection class: IP 21 Plain text display Short delivery time Power range: 50...1350 kW (65...1800 HP)

For complex, completely engineered DriveSystem in common cabinet design Flexible and modular hardware structure 6- and 12-pulse configuration up to 18 MW/

23,000 HP and more Pre-programmed applications:

Metals, Cranes, P&P application, Mining Power range: 10...18000 kW (13...23000 HP)

DC Drives Product Portfolio