2
Understanding Interfaces DataPhysics Instruments GmbH Raiffeisenstraße 34 • 70794 Filderstadt, Germany phone +49 (0)711 770556-0 • fax +49 (0)711 770556-99 [email protected] • www.dataphysics.de Technical information in this document is subject to change without prior notice. Errors and omissions excepted. © Copyright by DataPhysics Instruments GmbH, Filderstadt 2015. DCAT9-Paket-2015 1507-1/En Photos: Dreamstime, 2011; Adobe Stock, Norbert Heil. Text and Layout: Gerhard Maier 15 years tensiometer Proven technology new defined • set of Reference Weights RWS • set of Reference Weights , DKD certified RWS-C • sample vessels made of glass GS xx and PTFE GS xxP as well as cover plates CP xx • Du Noüy- ring RG 10 • ring aligning tool R-AT • Wilhelmy- plate PT 9 • cylindrical plate PT 10 • density determination set for solids DSS 11 and DSS12 • software SCAT 36 for the experiment control, the measure- ment and the analysis of the density of solids Additional accessories DCAT 9T basic instrument including: - high-precision weighing system with automatic or selec- tively external calibration with (certified) weight and mass standards - automatic electronic coupling lock for the balance - software controlled, motor-driven height positioning of the sample receptacles with variable speed - integrated measurement and control electronics with digi- tal thermometer - illuminated sample chamber - liquid temperature control unit TV 70 with Pt100 probe - software controlled magnetic stirrer - USB 2.0-interface with connection cable • Wilhelmy- plate PT 11 • Du Noüy- ring RG 11 • density determination set for liquids DIS 11 • 6 sample vessels made of glass 70 mm GS 70 • software SCAT 31 for the experiment control, the measure- ment and the analysis of the static-, time- and tempera- ture- dependent surface and interfacial tension, and Lamella breakpoint test to determine the surface elasticity • software SCAT 34 for the experiment control, the measure- ment and the analysis of the density of liquids Scope of delivery For more information about a tailor-made solution to your surface chemistry requirements, please contact us. We will be pleased to provide a quotation, obligation free, for your instrument system. Special offer Until 30. 11. 2015 The high degree of accuracy of the DCAT devices complies with all related international standards, for example: ISO 6295 Petroleum products -- Mineral oils -- Determination of interfacial tension of oil against water -- Ring method ISO 6889 Surface active agents; Determination of interfacial tension by drawing up liquid films ASTM D971 Standard Test Method for Interfacial Tension of Oil Against Water by the Ring Method ASTM D1417 Standard Test Methods for Rubber Latices-Syn- thetic DIN EN 14210 Surface active agents - Determination of in- terfacial tension of solutions of surface active agents by the stirrup or ring method ASTM D1331 Standard Test Methods for Surface and Inter- facial Tension of Solutions of Paints, Solvents, Solutions of Surface-Active Agents, and Related Materials ISO 304 Surface active agents; Determination of surface tension by drawing up liquid films DIN ISO 1409 Plastics/rubber - Polymer dispersions and rubber latices (natural and synthetic) - Determination of surface tension by the ring method OECD 115 OECD Guidelines for the Testing of Chemicals: Sur- face Tension of Aqueous Solutions Standards Your sales partner:

DCAT 9T ISO 6295 15 years tensiometer - Benelux Scientific · Understanding Interfaces DataPhysics Instruments GmbH Raiffeisenstraße 34 • 70794 Filderstadt, Germany phone +49 (0)711

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Understanding Interfaces

DataPhysics Instruments GmbHRaiffeisenstraße 34 • 70794 Filderstadt, Germanyphone +49 (0)711 770556-0 • fax +49 (0)711 [email protected] • www.dataphysics.de

Tech

nica

l inf

orm

atio

n in

this

doc

umen

t is

subj

ect t

o ch

ange

wit

hout

prio

r not

ice.

Err

ors

and

omis

sion

s ex

cept

ed.

© C

opyr

ight

by

Dat

aPhy

sics

Inst

rum

ents

Gm

bH, F

ilder

stad

t 201

5. D

CAT9

-Pak

et-2

015

1507

-1/E

nPh

otos

: Dre

amst

ime,

201

1; A

dobe

Sto

ck, N

orbe

rt H

eil.

Text

and

Lay

out:

Ger

hard

Mai

er

1 5 y e a r s t e n s i o m e t e rP r o v e n t e c h n o l o g y n e w d e f i n e d

• set of Reference Weights RWS • set of Reference Weights , DKD certified RWS-C• sample vessels made of glass GS xx and PTFE GS xxP as well

as cover plates CP xx• Du Noüy- ring RG 10• ring aligning tool R-AT• Wilhelmy- plate PT 9• cylindrical plate PT 10• density determination set for solids DSS 11 and DSS12• software SCAT 36 for the experiment control, the measure-

ment and the analysis of the density of solids

A d d i t i o n a l a c c e s s o r i e s

• DCAT 9T basic instrument including:

- high-precision weighing system with automatic or selec-tively external calibration with (certified) weight and mass standards

- automatic electronic coupling lock for the balance - software controlled, motor-driven height positioning of the sample receptacles with variable speed

- integrated measurement and control electronics with digi-tal thermometer

- illuminated sample chamber - liquid temperature control unit TV 70 with Pt100 probe - software controlled magnetic stirrer - USB 2.0-interface with connection cable

• Wilhelmy- plate PT 11• Du Noüy- ring RG 11• density determination set for liquids DIS 11• 6 sample vessels made of glass 70 mm GS 70• software SCAT 31 for the experiment control, the measure-

ment and the analysis of the static-, time- and tempera-ture- dependent surface and interfacial tension, and Lamella breakpoint test to determine the surface elasticity

• software SCAT 34 for the experiment control, the measure-ment and the analysis of the density of liquids

S c o p e o f d e l i v e r y

For more information about a tailor-made solution to your sur face chemistr y re quirements, p lease contac t us . We wil l b e p lease d to provide a quo tation, obl igation fre e, for your instrument system.

Special offer

Until 30. 11. 2015

The high degree of accuracy of the DCAT devices complies with all related international standards, for example:• ISO 6295 Petroleum products -- Mineral oils -- Determination

of interfacial tension of oil against water -- Ring method• ISO 6889 Surface active agents; Determination of interfacial

tension by drawing up liquid films• ASTM D971 Standard Test Method for Interfacial Tension of

Oil Against Water by the Ring Method• ASTM D1417 Standard Test Methods for Rubber Latices-Syn-

thetic• DIN EN 14210 Surface active agents - Determination of in-

terfacial tension of solutions of surface active agents by the stirrup or ring method

• ASTM D1331 Standard Test Methods for Surface and Inter-facial Tension of Solutions of Paints, Solvents, Solutions of Surface-Active Agents, and Related Materials

• ISO 304 Surface active agents; Determination of surface tension by drawing up liquid films

• DIN ISO 1409 Plastics/rubber - Polymer dispersions and rubber latices (natural and synthetic) - Determination of surface tension by the ring method

• OECD 115 OECD Guidelines for the Testing of Chemicals: Sur-face Tension of Aqueous Solutions

S t a n d a r d s

Your sale s par tner:

Measuring range for surface and interfacial tensions:

• 1 … 1000 mN/m; ± 0.01 mN/m resolution

Measuring range for densities:

• 0.50 … 2.50 g/cm3; ± 0.002 g/cm3 Auflösung

Weighing range: • 100 µg … 220 g

Measuring value range: • up to 50 weighing values/s

Travel speed of sample table:

• 46 nm/s … 12 mm/s

Programmable travel for sample table:

• 70 mm

Travel resolution: • 24 nm

Sample vessel holder: • TV 70

Balance calibration: • automatic internal and optional external with reference weight

Temperature measure-ment and range:

• -10 … 130 °C• 2 x Pt 100 inputs for -60 …

+450 °C (Pt 100 as option); ± 0.01 K resolution; precision 1/3 DIN IEC 751 (±0.03%), Class B

Automatic stirrer: • integrated, software controlled

Dimensions (L x W x H): • 250 x 205 x 500 mm (L x B x H)

Weight: • 15 kg

Power supply: • 100 … 240 VAC; 50 … 60 Hz; 70W

Te c h n i c a l d a t a

DCAT 9T with liquid temperature control unit TV 70, Wilhelmy- plate PT 11, Du Noüy-Ring RG 11 and density determi-nation set for liquids DIS 11

D C AT 9 TT h e f u l l y a u t o m a t e d t e n s i o m e t e r

The DCAT 9 has been completely redesigned from scratch. The core, a high-precision electrodynamic compensation weighing system, surrounded by state-of-the-art, modular electronics, enabling for example in conjunction with new stepper motors a sample stage positioning speed of 46 nm/s to 12 mm/s.The also completely redesigned software is operable tradition-ally, using mouse and keyboard or with multi- touch notebooks/pads by finger/pen.

Measuring methods• measurement of the static, time- and temperature-depend-

ent surface and interfacial tensions according to the Du Noüy-ring and the Wilhelmy plate method

• Lamella breakpoint test to determine the surface elasticity• automatic ring corrections according to Zuidema & Waters,

Mason & Huh and Harkins & Jordan• gas-, liquids- and solids data base• determination of the density of liquids

set of Reference Weights RWS