Page 1: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,
Page 2: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 2

Turbine flowmeters are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design and high reliability are required with either continuous or rapidly changing flow as well as fluctuating operating temperature and pressure. A variety of end fitting options allows the measuring instruments to be easily connected to the process piping. Applications The DM-Series turbine flowmeters are suited for a wide range of applications. These include monitoring of fuel, coolants and lubricants in engine development and construction, measurement of dosing quantities in the food and pharmaceutical sector, monitoring and measurement of high-purity water in the research and development sector, diesel consumption calculations and much more. Advantages New helical rotor blades design for improved linearity and lower pressure loss. Interference-free signal transmission (no-drift, digital pulse output). Precision ball bearings for better repeatability and optimum results at low flow rates. Very wide measuring range, up to 130:1 Integrated temperature sensor in the pickoff for real time correction of the effects of temperature and viscosity changes. Miniaturized, light weight versions for installation in applications where space is limited and vibration is of concern.

Flow meter manufacturing and calibration As a specialist in flow measurement technology, TrigasDM supplies high-quality measuring instruments, electronics and calibrators for liquids and gases as well as timely and efficient after-sales service and re-calibration though our Service company TrigasFI. Made in Germany Our products are exclusively developed and manufactured in Neufahrn, 20 km north of Munich, ensuring world-class technical know-how for our customers. Contact We are proud of our high-quality products and friendly customer service and welcome you as a valued customer to our growing family. You can benefit from our long-standing experience and our comprehensive technical support. TrigasDM GmbH Tel.: +49 8165 9999-300 Erdinger Str. 2b Fax: +49 8165 9999-369 85375 Neufahrn E-Mail: [email protected] Germany www.trigasdm.com

Page 3: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 3

Technical data Flow range: see "Measuring ranges" table Response time: <3 ms Temperature range: -270° C up to 400° C Operating pressure: up to 540 bar depending on connection AN: up to 540 bar

HS: up to 34 bar Tri-Clamp: up to 50 bar Viscosity: Each turbine is calibrated according to customer specifications and

delivered with individual calibration protocols. (Standard viscosity: 1.3 mm²/s)

Calibration accuracy: ≤±0.03% of reading Repeatability: ≤±0.05% of reading Linearity: ≤±0.5% of reading value in the linear flow range ≤±0.1% with linearization electronics Pressure drop: see table page 7 Standard material: Stainless steel

Measuring ranges

Model

Linear Range Extended Flow range K-Faktor1) max. Frequency1)

[l/min] [l/min] [Impulse/l] [Hz] RF2) and Mag3) RF2) Mag3) All

min. max. min. min. max.

DM2-8 0,54) 54) 0,05 0,4 5,5 14700 1350 DM4-8 0,95 12 0,1 0,4 13 8700 2000 DM6-8 1,9 20 0,2 0,5 24 4860 2000 DM8-8 2,8 33 0,3 0,6 38 3700 2100 DM-08 3,0 40 0,4 0,8 48 2400 2000 DM-10 4,5 60 0,6 1,1 70 1700 2000 DM-12 7,6 90 0,9 1,9 120 1000 2000 DM-16 19 220 2,2 3,8 240 450 1700 DM-20 34 400 3,8 6,0 490 240 1700 DM-24 57 700 6,0 10 820 110 1500 DM-32 83 1100 10 13 1300 65 1300 DM-40 151 1510 17 19 1700 28 800

1) The K-factors and frequency data are average values. Each turbine is calibrated according to customer

specifications and delivered with individual calibration protocols. 2) RF = Frequency-modulated pickoff 3) Mag = Magnetic pickoff 4) DM2-8 ≤±2% of reading

Page 4: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 4

Dimensions Other end fittings are available upon request. DM-Series AN: 1

DM-Series AN-Housing

Model

Inner Ø Housing [mm] Connection

Tube Ø AN-Size Pickoff

[mm] A B C ["] t [mm] Thread

DM2-8 7,6 62,2 22 / 22 ¾“ -16UNJF-3A 1/2 6,2 DM4-8 7,6 62,2 22 / 22 ¾“ -16UNJF-3A 1/2 6,2

DM6-8 9,4 62,2 23/23 ¾“ -16UNJF-3A 1/2 6,1

DM8-8 10,2 62,2 23/23 ¾“ -16UNJF-3A 1/2 5,7

DM-08 11,2 62,2 23/23 ¾“ -16UNJF-3A 1/2 6,2

DM-10 12,8 69,1 SW32 7/8” -14UNJF-3A 5/8 8,5

DM-12 14,3 82,6 SW32 1-1/16“ -12UNJ-3A 3/4 7,5

DM-16 21,9 90,4 SW36 1-5/16“ -12UNJ-3A 1 5,6

DM-20 25,4 103,1 SW41 1-5/8“ -12UNJ-3A 1 1/4 6,0

DM-24 33,4 116,6 SW50 1-7/8“ -12UNJ-3A 1 1/2 6,5

DM-32 44,5 154,0 SW65 2-1/2“ -12UNJ-3A 2 7,9

5/8”

– 1

8UN

F-2B

Page 5: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 5

DM-Series HS:

DM-Series HS-Standard

Model

Inner Ø Housing [mm] Connection Pickoff

[mm] A B C t [mm] Thread DM2-8 7,6 62,2 22 / 17 9,5 6,2

DM4-8 7,6 62,2 22 / 17 9,5 6,2

DM6-8 9,4 62,2 23/23 12,7 6,1

DM8-8 10,2 62,2 23/23 12,7 5,7

DM-08 11,2 62,2 25/25 12,7 6,2

DM-10 12,8 69,1 SW32 15,9 8,5

DM-12 14,3 82,5 SW32 19,1 7,5

DM-16 21,9 90,4 SW36 25,4 5,7

DM-20 25,4 103,1 SW41 31,8 6,0

DM-24 N/A N/A N/A N/A N/A

DM-32 N/A N/A N/A N/A N/A The total height is calculated from the height (B) of the flow meter plus measuring element minus the screw-in depth (t).

5/8”

– 1

8UN

F-2B

Page 6: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 6

DM-Series HS-L (lightweight - standard length)

Model

Inner Ø Housing [mm] Connection Pickoff

[mm] A B C t [mm] Thread DM2-8 7,6 62 22 / 17 9,5 6,1

DM4-8 7,6 62 22 / 17 9,5 6,1

DM6-8 9,4 62,2 22/19 12,7 6,1

DM8-8 10,2 62,2 22/20 12,7 6,1

DM-08 11,2 62,2 22/21 12,7 6,1

DM-10 12,8 69,1 22/22 15,9 6,1

DM-12 14,3 82,5 22/25 19,1 6,1

DM-16 21,9 90,4 29/33 25,4 6,1

DM-20 25,4 103 35/38 31,8 6,1

DM-24 33,4 116,6 42/46 38,1 6,1

DM-32 44,5 154 55/59 50,8 6,1

DM-40 59,7 154,5 Ø 85 64 6,1 The total height is calculated from the height (B) of the flow meter plus measuring element minus the screw-in depth (t).

DM-Series HS-K (short version - reduced length and weight)

Model

Inner Ø

Housing [mm] Connection Pickoff

[mm] A B C t [mm] Thread DM2-8 7,6 56 22 / 17 9,5 6,1

DM4-8 7,6 56 22 / 17 9,5 6,1

DM6-8 9,4 56,2 22/19 12,7 6,1

DM8-8 10,2 56,2 22/20 12,7 6,1

DM-08 11,2 56,2 22/20 12,7 6,1

DM-10 12,8 61,1 22/22 15,9 6,1

DM-12 14,3 69,8 22/25 19,1 6,1

DM-16 21,9 77,4 29/33 25,4 6,1

DM-20 25,4 85,1 35/38 31,8 6,1

DM-24 33,4 97,6 Ø 56 38,1 6,1

DM-32 44,5 124 Ø 70 50,8 6,1

DM-40 59,7 128 Ø 85 64 6,1 The total height is calculated from the height (B) of the flow meter plus measuring element minus the screw-in depth (t).

5/8”

– 1

8UN

F-2B

5/

8” –

18U

NF-

2B

Page 7: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 7

Pressure drop

Subsequently, the pressure losses at different flow rates are listed.

Model

Pressure drop [bar]

% of the max. linear flow

10% 25% 40% 55% 70% 85% 100%

DM2-8 0,00 0,01 0,03 0,05 0,08 0,11 0,15 DM4-8 0,01 0,03 0,06 0,16 0,19 0,27 0,35 DM6-8 0,01 0,02 0,06 0,11 0,16 0,23 0,32 DM8-8 0,01 0,05 0,11 0,20 0,30 0,46 0,61 DM-08 0,01 0,03 0,08 0,14 0,21 0,29 0,36 DM-10 0,06 0,12 0,23 0,41 0,61 0,92 1,22 DM-12 0,06 0,13 0,24 0,42 0,64 0,93 1,22 DM-16 0,06 0,09 0,16 0,27 0,39 0,57 0,74 DM-20 0,06 0,13 0,24 0,43 0,62 0,96 1,31 DM-24 0,07 0,16 0,32 0,60 0,89 1,32 1,74 DM-32 0,07 0,08 0,14 0,24 0,34 0,51 0,66 DM-40 0,03 0,06 0,13 0,21 0,40 0,45 0,61

Max. Operating pressure

Model

Max. operating pressure [bar]

AN HS DM2-8 540 34 DM4-8 540 34 DM6-8 450 34 DM8-8 410 34 DM-08 410 34 DM-10 410 34 DM-12 410 34 DM-16 350 34 DM-20 350 34 DM-24 250 34 DM-32 250 34 DM-40 N/A 34

Page 8: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 8

Piping Configuration Turbine flow meters can be affected by the flow profile of the fluid being measured. Installation with proper up- and downstream pipe sections will minimize and even completely eliminate flow profile induced measurement errors during calibration and operation. A straight run of pipe of at least 10 times the pipe diameter in an upstream direction, and 5 times the pipe diameter in a downstream direction are recommended (see figure and table). The upstream section should be fitted with flow straightening vane. Appropriate flow straightening sets (up- and downstream) are available on request.

Inlet section and outlet section, schematic diagram

Contamination / filter

All pipe sections and components in the metering line must be cleaned prior to the installation of the flow meter. Pipe Sealants, metal shavings and slag can damage the flow meter. If the cleanliness of the fluid cannot be guaranteed, a filter should be installed upstream of the flow meter, subject to the diameter of the flow meter. Model Inner Ø [mm] Filter mesh width DM2-8 7,6 10 Micrometer DM4-8 7,6 10 Micrometer DM6-8 9,4 10 Micrometer DM8-8 10,2 10 Micrometer DM-08 11,2 10 Micrometer DM-10 12,8 10 Micrometer DM-12 14,3 10 Micrometer DM-16 21,9 20 Micrometer DM-20 25,4 20 Micrometer DM-24 34,4 50 Micrometer DM-32 44,5 50 Micrometer DM-40 59,8 50 Micrometer

Page 9: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 9

Explosion protection (ATEX)

• Pickoffs and electronics can be supplied in explosion proof versions (ATEX) on request. With explosion proof electronics, TrigasDM turbine flow meters can be used in environments as severe as Ex-Zone 1.

• The design consists of the turbine flow meter and the ATEX Pickoff. The following type of protection applies to this construction:

ATEX: II 1 G Ex ia IIC FM08ATEX0066X USA: Intrinsically Safe Class I, II, III, Division 1 GROUP ABCDEFG Class I, Zone 0, AEX ia IIC Canada: Intrinsically Safe Class I, Division 1 GROUP ABCD Class I, Zone 0, AEX ia IIC

• The turbine flow meter is installed in the hazardous area.

• The mounting of the barrier and the TriLIN is carried out in the safe area.

• Without barriers, the turbine flow meter must not be operated in the hazardous area.

• Cable lengths of up to 400 m are possible depending on the safety barrier used.

Page 10: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 10

Model numbering key

The type number describes the properties of the measuring instrument. Model numbering key DM-Series (e.g. DM-16AN-BC-1-S)

Type code: #1 #2 #3 #4 #5 #6 .. .. .. .. .. ..

Example: DM -16 -AN -BC -1 -S

1 Code Typ DM

2 Code Size/ Measuring range liquids Restrictions

sensor Sensor

2-8 iØ 7,6 mm; up to 5,5 l/min 4-8 iØ 7,6 mm; up to 13 l/min 6-8 iØ 9,4 mm; up to 24 l/min 8-8 iØ 10,2 mm; up to 38 l/min -08 iØ 11,2 mm; up to 48 l/min -10 iØ 12,8 mm; up to 70 l/min -12 iØ 14,3 mm; up to 95 l/min -16 iØ 21,9 mm; up to 240 l/min -20 iØ 25,4 mm; up to 490 l/min -24 iØ 33,4 mm; up to 820 l/min

-32 iØ 44,5 mm; up to 1300 l/min -40 iØ 59,7 mm; up to 1700 l/min

3 Code Process connection Restrictions

Process connection

AN AN Male thread up to DN32 HS Hose connection NE NPT thread up to DN32 BE BSP male thread up to DN32 C1 Flange 150# up to DM-20 C4 Flange 900#, PN160 up to DM-32 T1 Tri-Clamp ½” – ¾”, plate Ø 2,5 mm up to DM-12 T2 Tri-Clamp 1” – 1½”, plate Ø 50,5 mm up to DM-16 T3 Tri-Clamp 2”, plate Ø 64,0 mm from DM-16 T4 Tri-Clamp 2 ½”, plate Ø 77,5 mm from DM-16

4 Code Bearings Restrictions

Bearings -BC Ball bearings, ceramic -BA Ball bearings, stainless steel on request

5 Code Material, housing and internals Restrictions Material -1 Stainless steel

6 Code Housing Restrictions

Housing -S Standard -L Light weight version -K Light weight / short version

Page 11: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 11

Model numbering key Pickoff (e.g. R0410C20). Each turbine is equipped with a sensor, which receives the signals and transmits them to the evaluation electronics (see separate brochure).

Type code*: #1 #2 #3 #4 #5 #6 #7 .. .. .. .. .. .. ..

Example: R 0 4 1 0 C2 0

*Note: Pickoffs are not configurable, available versions on request.

1 Code Signal Restriction

Signal

R Frequency modulated pickoff (RF signal) A Amplifier pickoff (TTL Signal) M Magnetic pickoff T ATEX L SMART pickoff for Lysis SP V01 - V04 W SMART pickoff for Lysis SP V05 X Special version

2 Code Gauss number Restriction

Gauss number

0 Without / RF Signal 1 100 2 150 3 200 4 250 5 400 6 800 X Special version

3 Code Temperature Restriction

Temperature range

1 Range -40…125°C SMART pickoffs

2 Range -55… 125°C

3 Range -55…177°C RF low profile pickoffs

4 Range -74…204°C

5 Range -200…230°C 6 Range -268… 232°C 7 Range -40…65°C X Special version

4 Code Thread / Design Restriction

Thread / Design

1 5/8-16, high profile 2 5/8-16, low profile with output cable 4 11/16-24, high profile 5 11/16-24, low profile with output cable X Special version

Page 12: Datasheet · Datasheet DM-Series Turbine flowmeters. TrigasDM GmbH 2019/05 2 Turbine flowmeters . are the ideal solution for measuring applications in liquids when high accuracy,

Datasheet DM-Series Turbine flowmeters

TrigasDM GmbH 2019/05 12

5 Code Cable length Restriction

Cable length

0 Without cable 1 Cable 1 m 2 Cable 2 m 3 Cable 3 m 4 Cable 4 m 5 Cable 5 m 6 Cable 6 m 9 Cable 0,2 m X Cable X m

6 Code Connector Restriction

Connector

P1 Without connector, instead with NPT 1/2" thread and cable open leads

for direct fitting on transmitter

C1 MS Bayonet connector 4 PIN on pickoff, high temperature 400°C

C2 MS Bayonet connector 2 PIN on pickoff only for TriLIN without temperature compensation

C3 MS Bayonet connector 3 PIN on pickoff C4 MS Bayonet connector 4 PIN on pickoff K1 Cable open leads O1 ODU connector IP68, 8 PIN, at pickoff cable only Lysis version V04

O2 ODU connector IP68, 5 PIN, at pickoff cable only Lysis version V05

O3 ODU connector IP52 half shell 5 PIN, FIPS, at pickoff cable

only Lysis version V06

O4 ODU connector IP52 half shell 7 PIN, at pickoff cable

only TriLIN

Y1 Y cable with 2 ODU connectors, IP52 half shell 5 PIN, FIPS, at pickoff cable

only TriLIN LIN-T1-01-M2-0-U3-V1

X Special version 7 Code Temperature compensation Restriction

Temperature sensor