DataComm ® 9600R / 9600R/IFP

Installation and O peration

058R467-000 Issue 1April 2000

Page 2: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description
Page 3: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

058R467-000Issue 1April 2000

DataComm ® 9600R / 9600R/IFP

Installation and Operation

Page 4: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

. No y , Inc. sumes

ited

panies

c.)

Copyright©2000 General DataComm, Inc. ALL RIGHTS RESERVED.

This publication and the software it describes contain proprietary and confidential informationpart of this document may be copied, photocopied, reproduced, translated or reduced to anelectronic or machine-readable format without prior written permission of General DataCommThe information in this document is subject to change without notice. General DataComm asno responsibility for any damages arising from the use of this document, including but not limto, lost revenue, lost data, claims by third parties, or other damages.

If you have comments or suggestions concerning this manual, please contact:

General DataComm, Inc.Network Access DivisionTechnical Publications DepartmentPark Road ExtensionMiddlebury, Connecticut USA 06762-1299

Telephone: 1 203 758 1811

TrademarksAll brand or product names are trademarks or registered trademarks of their respective comor organizations.

Documentation

Revision Histor y

Related Publications

A listing of related user manuals is provided below. In addition to the hardware and softwaremanuals, always read the software System Release Notes supplied with your product.

* For publications numbers, REV is the hardware manual revision (for example, -000, -001, etVREF (if listed) is the software revision (for example, -V120 would read, Version 1.2) and corresponds to the most current revision.

Issue Number Date Description of Change

1 April 2000 Initial Release

Publication Name Publication Number*

ii DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 5: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

ly eir ou

Preface

ScopeThis manual describes how to install and operate the DataComm 9600R / 9600R/IFP. The information contained in this manual has been carefully checked and is believed to be entirereliable. However, as General DataComm improves the reliability, function, and design of thproducts, it is possible that information may not be current. Contact General DataComm if yrequire updated information for this or any other General DataComm products.

General DataComm, Inc.Network Access DivisionTechnical Publications DepartmentPark Road ExtensionMiddlebury, Connecticut, USA 06762-1299Tel: 1 203 758 1811 Toll Free: 1 800 794 8246

Manual OrganizationThis manual is divided into the following sections:

Chapter 1, Introduction

Chapter 2, Installation

Chapter 3, Operation

Chapter 4, Tests

Chapter 5, Intelligent Front Panel

Appendix A, Technical Characteristics

Appendix B, Equipment List

Appendix C, Business Equipment Interface Signals

Appendix D, Pin Designations

058R467-000 DataComm 9600R / 9600R/IFP iiiIssue 1 Installation and Operation

Page 6: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Preface

rior to elow.

re tor. s for afety

ous

d.

tion.

ge.

n

ult

n

Safety InformationThis manual should be read in its entirety and all procedures completely understood beforeinstalling or operating the unit. The notes that appear throughout this manual must be read pany installation or operating procedure. Examples of notes used in this manual are shown b

The CAUTION, WARNING, and DANGER statements that appear throughout this manual aintended to provide critical information for the safety of both the service engineer and operaThese statements also enhance equipment reliability. The following definitions and symbolCAUTION, WARNING, and DANGER as they are used comply with ANSI Z535.2, AmericanNational Standard for Environmental and Facility Safety Signs, and ANSI Z535.4, Product SSigns and Labels, issued by the American National Standards Institute.

Safety GuidelinesAlways use the following guidelines when unsafe conditions exist or when potentially hazardvoltages are present:

• Always use caution and common sense.

• Repairs must be performed by qualified service personnel only.

• To reduce the risk of electrical shock, do not operate equipment with the cover remove

• Never install telephone jacks in a wet location unless the jack is designed for that loca

• Never touch uninsulated telephone wires or terminals unless the telephone line is disconnected at the network interface.

• Never install telephone wiring during an electrical storm.

Note Indicates a note. It is something you should be particularly aware of; something not readilyapparent. A note is typically used as a suggestion.

Important Indicates an emphasized note. It is something you should be particularly aware of; something not readily apparent. Important is typically used to prevent equipment dama

CAUTION Indicates a potentially hazardous situation which, if not avoided, may result iminor to moderate injury. It may also be used to alert against unsafe practices.

WARNING indicates an imminently hazardous situation which, if not avoided, could resin death or serious injury.

DANGER indicates an imminently hazardous situation which, if not avoided, will result ideath or serious injury.

iv DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 7: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Preface

puter atic hat are l when

ring

ipment on .

by ch

vides e the

ne ot laint mpany d the

o

use

Antistatic Precautions

Electrostatic discharge (ESD) results from the buildup of static electricity and can cause comcomponents to fail. Electrostatic discharge occurs when a person whose body contains a stbuildup touches a computer component. This product may contain static-sensitive devices teasily damaged. Proper handling, grounding and precautionary ESD measures are essentiainstalling parts or cards. Keep parts and cards in antistatic packaging when not in use or dutransport. If possible, use antistatic floorpads and workbench pads.

When handling components, always use an antistatic wrist strap connected to a grounded equframe or chassis. If a wrist strap is not available, periodically touch an unpainted metal surfacethe equipment. Never use a conductive tool, like a screwdriver or a paper clip, to set switches

FCC Part 68 Compliance

Connection of data communications equipment to the public telephone network is regulatedFCC Rules and Regulations. This equipment complies with Part 68 of these regulations whirequire all of the following:

All connections to the telephone network must be made using standard plugs and telephonecompany provided jacks or equivalent. Connection of this equipment to party lines and cointelephones is prohibited. A label on the component side of the unit’s printed circuit board prothe FCC Registration number for the unit. If requested, give this information to the telephoncompany. To connect the product to the Public Telephone Network, you are required to givefollowing information to the telephone company:

• FCC Registration Number: TBD

• Facility Interface Codes: 04DU9-BN, 04DU9-DN, 04DU9-1KN, 04DU9-1SN

• Service Order Code: 6.0Y

• Telephone Company jack type: RJ48C

The telephone company may discontinue your service if the unit causes harm to the telephonetwork. If possible, you will be notified of such an action in advance. If advance notice is npractical, you will be notified as soon as possible and will be advised of your right to file a compwith the FCC. The telephone company may change its communication facilities, equipment,operations and procedures where reasonably required for operation. If so, the telephone cowill notify you in writing. All repairs or modifications to the equipment must be performed byGeneral DataComm. Any other repair or modification by a user voids the FCC registration anwarranty.

Part 15 Compliance

This device complies with Part 15 of the FCC rules. Operation is subject to the following twconditions:

1. This device may not cause harmful interference and

2. This device must accept any interference received, including interference that may caundesired operation.

058R467-000 DataComm 9600R / 9600R/IFP vIssue 1 Installation and Operation

Page 8: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Preface

ice

d nters

TAL

Service Support and TrainingVITAL Network Services, a General DataComm company, is committed to providing the servsupport and training needed to install, manage, and maintain your GDC equipment. VITAL Network Services provides hands-on training courses through VITAL Network Services Global Technology Training Services. Courses range from basic data communications, modems anmultiplexers, to complex network and ATM systems. Training courses are available at our cein the US, UK, France, Singapore and Mexico, as well as at a customer’s site.

For more information VITAL Network Services or for technical support assistance, contact VINetwork Services at:

VITAL Network Services World Headquarters6 Rubber Avenue Telephones: Faxes:Naugatuck, Connecticut 06770 USA 1 800 243 1030 1 203 723 5012

1 888 248 4825 1 203 729 7611http//www.vitalnetsvc.com 1 203 729 2461

VITAL Network Services Regional Sales and Service Offices:

North American Region Office6 Rubber AvenueNaugatuck, Connecticut 06770 USATelephones: 1 800 243 1030

1 888 248 48251 203 729 24611 800 361 2552 (French Canadian)

Training: 1 203 729 2461Faxes: 1 203 723 5012

1 203 729 7611

Central America, Latin AmericaVITAL Network ServicesPeriferico Sur 4225, Desp. 306C.P. 14210, Mexico D.F., Mexico

Telephone: 52 5 645 2238Training: 52 5 645 2238Fax: 52 5 645 5976

Europe, Middle East, AfricaVITAL Network ServicesMolly Millars CloseMolly Millars LaneWokingham, Berkshire RG41 2QF UK

Telephone: 44 1189 657200Training: 44 1189 657240Fax: 44 1189 657279

Asia PacificVITAL Network Services501 Orchard Road 05-05Wheelock Place, Singapore 238880

Telephone: 65 735 2123Training: 65 735 2123Fax: 65 735 6889

vi DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 9: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Table of Contents

-2

1

1

4

4

-7

2

1

2

2

Chapter 1: IntroductionDescription............................................................................................................................. 1-1

DataComm 9600R Modem Features...................................................................................... 1-2

Diagnostics............................................................................................................................. 1-2

Applications........................................................................................................................... 1

Chapter 2: InstallationUnpacking and Handling....................................................................................................... 2-1

Preoperational Check............................................................................................................. 2-

Installation Procedures........................................................................................................... 2-

Standalone Installation.....................................................................................................2-1

Rackmount Installation.....................................................................................................2-3

Electrical Connections........................................................................................................... 2-

Standalone Enclosure.......................................................................................................2-4

Rackmount Shelf..............................................................................................................2-

Business Equipment Connections (Data Terminal).........................................................2-5

VF Line Connections........................................................................................................2-6

Dial Backup Connections.................................................................................................2-7

Option Selection..................................................................................................................... 2

Installation Recommendations............................................................................................... 2-7

Chapter 3: OperationControls, Indicators and Connectors...................................................................................... 3-1

Dial Backup Option............................................................................................................... 3-

Dial Backup (DBU-89).....................................................................................................3-2

DBU-89 Diagnostics........................................................................................................3-2

Special Considerations for Use with RPA Units................................................................... 3-3

Chapter 4: TestsAnaloop with Self-Test.......................................................................................................... 4-

Chapter 5: Intelligent Front PanelIntelligent Front Panel (IFP) Description............................................................................... 5-1

Installation, Operation and Testing........................................................................................ 5-2

Keypad Operation.............................................................................................................5-

IFP Operation...................................................................................................................5-

058R467 -000 DataComm 9600R / 9600R/IFP viiIssue 1 Installation and Operation

Page 10: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Table of Contents

9

9

0

11

1

5

23

7

0

3

6

7

8

Changing Parameters....................................................................................................... 5-4

IFP Modes Of Operation.................................................................................................. 5-7

Intelligent Pointer Feature................................................................................................ 5-8

Gaining Access To A Unit............................................................................................... 5-8

Operating Routines................................................................................................................ 5-

Product Level................................................................................................................... 5-

Password Level.............................................................................................................. 5-1

Log On........................................................................................................................... 5-

Engage............................................................................................................................ 5-2

Attach............................................................................................................................. 5-13

Configuration................................................................................................................. 5-1

Monitor........................................................................................................................... 5-

Diagnostics..................................................................................................................... 5-2

Maintenance................................................................................................................... 5-3

Restoral.......................................................................................................................... 5-3

DBU-89 Directory.......................................................................................................... 5-3

Interim Messages................................................................................................................. 5-3

Error Messages.................................................................................................................... 5-3

Setup and Installation Using the IFP................................................................................... 5-39

Multi-point Synchronous Set-up.................................................................................... 5-39

Multi-point Asynchronous Set-up.................................................................................. 5-40

Tests..................................................................................................................................... 5-41

Appendix A: Technical Characteristics

Appendix B: Equipment List

Appendix C: Business Equipment Interface Signals

Appendix D: Pin Designations

viii DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 11: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

g to 4800

ollable e dem

of-c

ll as

y/

to the

Chapter 1: Introduction

DescriptionThe DataComm 9600R and 9600R/IFP Modems provide the capability through soft optioninsupport a primary data rate of 9600 bps, and fallback rates of 7200 bps (in V.29 mode) andbps. The modems support point-to-point or multipoint applications and synchronous or asynchronous data formats. The DataComm 9600R modems are completely software contrand all configuration options, including the network address, can be downline loaded from thcentral site. Remote site installation/replacement is thus simplified since modem options areconfigured from the Intelligent Front Panel. All configuration operations are stored by the moin the nonvolatile memory.

The DataComm 9600R modem includes an integral diagnostic design that overlays an "out-band" or secondary diagnostic channel onto the modem communication link. This diagnostichannel provides a communication path for the IFP controller, permitting continuous, noninterfering monitoring of Voice Frequency (VF) line parameters, digital EIA leads, as wethe modem's own internal operation.

Two inbound/outbound control signals are offered with the units allowing remote supervisorsecurity capability. An optional DBU-89 (single-call) Dial Backup Card is also available to maintain communications in the event of primary circuit failure. Part numbers of models andassemblies available for the DataComm 9600R, as well as DataComm9600R/IFP with the Intelligent Front Panel, are listed in Appendix B. Technical characteristics are given in Appendix A.

The first 4 chapters of this manual refer specifically to the DataComm 9600R, but also apply DataComm 9600R/IFP. Information specific to the DataComm 9600R/IFP is found in Chapter 5, Intelligent Front Panel.

Figure 1-1 DataComm 9600R Front Panel

Figure 1-2 DataComm 9600R/IFP Front Panel

DC9600RSD RD TRRS CS CO NORM DBUCRAFT SQ TEST

OK CO DATA RESP TESTNORM TESTMODEM MANAGEMENT

DC9600R SD RD TRRS CS CO NORM DBUCRAFT SQTESTOK CO DATA RESP TEST

NORM TESTMODEM

ESC PREV NEXT SEL

IFP

Liquid CrystalDisplay (LCD)

Strap for enabling or disabling password protectionlocated on pc board in rear of IFP at this location

MANAGEMENT

DIS EN

058R467-000 DataComm 9600R / 9600R/IFP 1-1Issue 1 Installation and Operation

Page 12: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Introduction DataComm 9600R Modem Features

lines. nt plete nder ted

DataComm 9600R Modem Features• Software controlled, permits configuration/reconfiguration, diagnostic testing, and system

restoral through Intelligent Front Panel, without the need for remote site intervention.

• Custom VLSI technology with microprocessor control to minimize size and power consumption.

• Supports single-call Dial Backup through the use of an optional DBU-89 plug-in card.

• Super polling capability at 9600 bps; RTS/CTS delay 10 ms or less.

• Alternative Intelligent Front Panel, (see Chapter 5, Intelligent Front Panel for details).

DiagnosticsDiagnostics are controlled by the DataComm 9600R Intelligent Front Panel. See Chapter 5, Intelligent Front Panel.

ApplicationsThe DataComm 9600R is designed for full duplex operation over four-wire 3002-type private The DataComm 9600R is part of a complete family of low to high speed single and multipoidiagnostic modems available for stand-alone and rackmount applications. It provides a comrange of network management functions as part of an integrated communications network uIFP control. Using this system, complex data communication networks may be accommodainvolving a wide variety of topologies and transmission media.

Note Minimum of one 9600R/IFP is required per system.

1-2 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 13: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

t the ing

f-Test inal. g is cted

.

d port,

echeck

odem ace of

osure, where

power talling

Chapter 2: Installation

Unpacking and Handling

The DataComm 9600R is shipped in packing material enclosed in a corrugated box. Inspecmodem for damage; if any, notify the shipper immediately. Do not discard the box and packmaterial; their use will facilitate reshipping the unit, if necessary.

Preoperational Check

The modem should be given a preoperational check by performing an Analog Loopback Seland ANALOOP test to verify normal operation before it is connected to the VF line and termSee Chapter 4, Tests for instructions on performing these tests. First verify that option strappinthe same as shown in Figure 2-1, and perform the test on a standalone modem before it is conneto anything except ac power, and on shelf plug-in modems as they are individually installed

If the modem passes these tests, notify the IFP operator to perform a What Are You? command. This verifies that the appropriate serial-numbered unit is installed on the line.

Ask the IFP operator to send commands to the unit. If data is sent from the IFP on the installethe Data light should flash. If the addressed unit responds to the data the Resp light will be on.

The remote unit indicates the above; in addition the CO light will be on, indicating that the unit is receiving a carrier signal.

If the modem fails to pass data, some error has been made in installation or configuration. Rthe cable wiring, optioning, and configurations, and perform the tests in Chapter 4, Tests to isolate the fault. In the event that the modem does not check out properly, replace it with a spare mand recheck. For assistance, refer to the “Service, Support and Training” section in the prefthis manual.

Installation Procedures

The DataComm 9600R modem's printed circuit card may be mounted in a DataComm EnclDataComm Shelf, or Universal System Shelf. The unit should be located in a ventilated areathe ambient temperature does not exceed 122oF. Do not install the modem directly above other equipment that generates large amounts of heat such as power supplies.

Standalone Installation

If it is necessary to remove the component card(s) from the standalone base, disconnect thesupply connector from J1, which is mounted at the rear center of the base card. When reinsthe component card(s) in the base, reinstall the connector at J1.

CAUTION

Disconnect power supply and phone connections prior to removal of the modem cover.

058R467-000 DataComm 9600R / 9600R/IFP 2-1Issue 1 Installation and Operation

Page 14: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Installation Installation Procedures

Figure 2-1 Option Location for DataComm 9600R Base Card

J3J2

J1

FL1

XA

1J1

FL2

100GND

CG-SG

X1

In 100 position, frame and signal grounds areisolated by a 100-OHM resistor. In CG-SG positionframe and signal grounds are connected.Factory shipped with jumper in 100 position.

J2

J4

Accommodates IntelligentFront Panel

S1

XA1J2

058P118-001

Note: Jumpers are shown in factory-shipped position.

CRAFT

TB1

1

4RX

TX

U19

0040XXXXXXXXXXXX058Z118-706

Serial Number(16 digits)

2-2 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 15: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Installation Installation Procedures

tional yback

p and

).

teen helf

b mates ctly in

Figure 2-2 Option Location for DBU-89 Dial Backup Card

Rackmount Installation

The DataComm 9600R may be mounted in a DataComm Shelf (DS-1, DS-5, DS-6 or internaequivalents) which support as many as sixteen DataComm 9600 cards. With the DBU-89 piggcard installed on the base card, the shelf accommodates eight cards.

To install the unit in the shelf, proceed as follows:

a. Position the modem base card in the top and bottom slot guides with the GDC logo on tocarefully slide the assembly into the slot until it stops at the rear connectors.

b. Push the front panel with both hands until the assembly mates with the rear connector(s

The Universal System Shelf (USS-1) may also be used and accommodates as many as sixDataComm 9600R cards. With the DBU-89 piggyback card installed on the base card, the saccommodates eight cards.

Each backplane assembly is keyed by a tab located at the bottom of the harness card. This tawith a slot which is part of the shelf and prevents the backplanes from being inserted incorrethe shelf.

J2

P2

P3

A1P1

J1

X2 Not a customer option. Do notinstall jumpers on these pins.

Connects to connector XA1J1on 9600R Base Card.

X3

600

900

PROG

X1

PERM

A1P2

S1

Connects to connector XA1J2on 9600R Basecard.

Transmit level to switched network iseither Permissive (-9 dB) with jumper in PERM (Permissive) position.

Switched network Line Impedance is either600 OHMS (Domestic) or 900 OHMS (Canada).Factory shipped with jumper in 600 position.

058P119-001

Note: Jumpers are shown in factory-shipped position.

058R467-000 DataComm 9600R / 9600R/IFP 2-3Issue 1 Installation and Operation

Page 16: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Installation Electrical Connections

liding th

uides lug in d

ctions

lug. t be ent ource, nding

er

s t

ent

To install the DataComm 9600R into the USS-1 shelf, proceed as follows:

a. Loosen the backplane screws and install the plug-in card from the front of the shelf by sit into the card guides. Seat firmly into the mating connectors on the backplane using bohands.

b. Tighten the backplane screws. This assures perfect alignment of the cards in the card gand the mating connectors on the backplane and allows for easy removal of the cards. Pthe four-pin cable harness on the backplane adapter to the shelf power connector locatedirectly above the backplane adapter.

Electrical ConnectionsThe following paragraphs describe the power line, business equipment and private line conneto the DataComm 9600R modem.

Standalone Enclosure

The modem is equipped with a captive ac power cord terminated in a molded three-prong pConnect the cord to a polarized outlet providing the required ac power. The outlet should nounder switch control. The modem should be powered by the same ac source as the equipminterfaced with the unit to prevent large circulating currents caused by differences in groundpotential. If it is not possible to determine whether the equipment is powered by the same ac sit should be verified that a potential difference of less than 0.25 V rms exists between the groucircuits of the respective power outlets.

Rackmount Shelf

The modem obtains power directly from the Shelf when properly installed as instructed undRackmount Installation.

Note When installing the modem base card with the DBU-89 Dial Backup Card, insert both cardinto the front of the Shelf. Be sure that the DBU-89 edge connector mates with the adjacenTELEPHONE connector located along the lower part of the shelf.

CAUTION This unit incorporates fusible links, FL1 and FL2, (illustrated in Figure 2-1), which may be opened if the ground potential exceeds 0.25 V rms between the unit and peripheral equipment. Do not apply power to the modem until all connections to peripheral equipmhave been made. If a fusible link is opened in a modem, return the unit to the factory forrepair.

2-4 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 17: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Installation Electrical Connections

25-pin elf, as

Business Equipment Connections (Data Terminal)

Connect the business equipment (data terminal) to the DataComm 9600R by means of the EIA-232-D connector on the rear panels of the stand-alone enclosure and the rackmount shshown in Figure 2-3 and Figure 2-4. When making a shelf connection, verify that the EIA-232-Dconnector corresponds to the shelf receptacle in which the modem card is installed.

Figure 2-3 DataComm Standalone Enclosure Rear Panel and PC Board Connections

BUSINESS EQUIPMENTPRIVATE LINE

SWITCHEDNETWORK

2W

ACPWR

Cover

Cable No. 023H101-XXX

BASE CARD - COMPONENT SIDE

TB1

Black

Yellow

Red

Green

Alternate PrivateLine Connections

DBU-89 Switched Network Cable

PRIVATE LINE

117V 60Hz0.2 Amps

RJ45 modular connector.Preferred Private Line

connection

or

RX TXBlack (3)Yellow (4)

Red (2)Green (1)

Cable No.830-028-8XX

4 1

058R467-000 DataComm 9600R / 9600R/IFP 2-5Issue 1 Installation and Operation

Page 18: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Installation Electrical Connections

of four--028-n no. d

o the unted irst be have rt the lace

e shelf

Figure 2-4 Shelf Rear Panel Connections Showing Optional DBU-89 Switched Network Dial Backup Connections

VF Line Connections

When the DataComm 9600R is installed in the Standalone Enclosure, the preferred method wire private line connection is by inserting the connector on the private line (GDC part no. 8308XX can be used) into the modular RJ45 connector located on the enclosure's rear panel. Aalternate method of private line connection is by routing the four-wire private line (GDC part023H101-XXX can be used) through the "PRIVATE LINE" access hole on the rear panel anconnecting it to the four terminal screws as illustrated in Figure 2-3 . (Refer to Appendix D for pin designations.)

If the modem is rackmounted in a DataComm Shelf, the four wire private line is connected ttop four screws of the terminal block mounted on the shelf’s rear panel. If the modem is moin the Universal System Shelf, the plastic cover attached at the rear of the backplane must fremoved to expose the VF terminal blocks. These blocks accommodate wires which do notterminal lugs. Remove the lugs and a portion of the insulation on the existing cable and insewires into the block by first unscrewing the captive screw for that portion of the terminal. Repthe plastic cover. (Refer to Appendix D for pin designations.)

In either case, before making the connection, verify that the terminal block corresponds to threceptacle in which the modem card is installed. See Figure 2-4.

T

R

PC/DT

PR/DR

MIC/TEK 5

MIC/TEK 6

+

12

34

56

TELEPHONE

TELEPHONE

USINESS

EQUIP

BUSINESS

EQUIP

B

BusinessEquipmentConnection

9600RCard

DBU-89Card

9600RCard

DBU-89Card

DS-1 DataComm SelfRear Panel

Model No. DC-1/BPNo. DC-2/BP

USS-1 Universal SystemShelf Rear Panel

TRPC/DTPR/DRMIC/TEK 5MIC/TEK 6

12

34

56

Private LineConnection

Alternate 2-wireSwitched Network Line

2-wire SwitchedNetwork Line

2-6 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 19: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Installation Option Selection

the

p e are rial

unit s.

ator ith

ed to

Dial Backup Connections

DBU-89 Card Option - Connect the switched network line directly to the modular receptaclelabeled "Switched Network 2W” on the rear of the standalone enclosure (see Figure 2-3). For the shelf installation, connect the switched network line directly to either the terminal block or tomodular receptacle located on the rear of the shelf (see Figure 2-4).

Option SelectionMost options on the DataComm 9600R are soft option controlled by the IFP. A port-line-dromethod of addressing is incorporated in the IFP system. A port address is determined by thconnection of the master modem to the IFP controller. The modem line and drop addressesselected by the operator of the IFP by assigning the appropriate addresses based on the senumber of the product that is in the system.

Although the Auto-Verify Routine may be used in most cases to find the serial number of thewithout opening the unit, this may not always be possible because of various line disruptionTherefore, the serial number should be reported initially when installing the unit. Table 2-1 provides application notes for each hard option available on the DataComm 9600R modem.

Installation RecommendationsAs all set up options and tests are administered by the Intelligent Front Panel, see Setup and Installation Using the IFP on page 5-39 for details.

Note All 9600R products contain a serial number. This number must be reported to the IFP operwhen the system is initially installed and configured. The 16-digit serial number (beginning w0040) of the modem is found on the top two lines of the U19 PROM label. Refer to Figure 2-1 for location of the PROM. In standalone enclosures, the cover of the modem must be removgain access to the serial number. Disconnect power supply and phone connections prior to removal of the cover.

Table 2-1 Option Application Notes

Option Description

Frame ground/Signal ground X1 selects grounding. In 100 position, frame and signal grounds are isolated by a 100-ohm resistor. In CG-SG position, frame and signal grounds are connected. Factory shipped with jumper in 100 position.

600/900 Transmit and Receive impedance (DBU-89)

A line impedance of 600 ohms may be selected to accommodate different line characteristics. 600 ohms is used for domestic applications; Canada typically uses 900 ohms. DBU-89 uses X3.only. Normally, factory shipped in 600 ohm position.

Programmable or Permissive(DBU-89)

The output level of the telephone line is set by a telephone company installed resistor (Programmable) or by the internal resistor in the modem (Permissive). The DBU-89 uses X1 for selection. Normally, factory shipped in the Permissive position.

058R467-000 DataComm 9600R / 9600R/IFP 2-7Issue 1 Installation and Operation

Page 20: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Installation Installation Recommendations

2-8 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 21: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

of the the unit

plains

Chapter 3: Operation

Overview

This section describes the controls, indicators and connectors of the modem. All operationsDataComm 9600R are controlled by the IFP. Once the external connections are made, and is configured, it functions automatically. Refer to Chapter 4, Tests for test procedures.

Controls, Indicators and ConnectorsThe illustration and table below illustrates the DataComm 9600R modem front panel and exthe function of each control and indicator. (DataComm 9600R/IFP is explained in Chapter 5, Intelligent Front Panel .)

Table 3-1 DataComm 9600R Front Panel

ID Type Action

SQ LED Lights when good signal quality is received.

SD LED Lights when a space is detected in transmitted data.

RD LED Lights when a space is detected in received data in data mode.

RS LED Lights when terminal has data to send.

CS LED Lights after RS is lit and after set modem delay.

CO LED Lights when the carrier is received from the line or test mode.

TR LED Lights when terminal is ready to transmit and receive.

NORM LED Lights when data set is ready to pass data (except when MANAGEMENT test indicator is on).

TEST OK LED Lights when in local loopback self-test. Flashes at errors.

DBU LED Lights if Dial Backup line is active.

CO LED Lights when carrier is received on secondary channel.

DATA LED MASTER - Lights when communicating with IFP or when communicating to a remote through front panel jack or secondary channel.REMOTE - Lights when it is receiving secondary channel data from a master via front panel jack or through secondary channel.

RESP LED Lights when responding on the secondary channel if it is a remote, or is passing a response from itself to the IFP if it is a master.

TEST LED Lights when MANAGEMENT has initiated a test.

(Sheet 1 of 2)

DC9600RSD RD TRRS CS CO NORM DBUCRAFT SQ

TESTOK CO DATA RESP TEST

NORM TESTMODEM

DIALDBU-89 Dial Backup Card (optional)

MANAGEMENT

058R467-000 DataComm 9600R 3-1Issue 1 Installation and Operation

Page 22: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Operation Dial Backup Option

V ac

pplied ed in

omm r g, and ial

ller.

n tests

st to test ork,

tor nec-

Figure 2-3 (see Chapter 2) illustrates the standalone enclosure rear panel connectors for 117voltage bases.

Rackmount shelf front panel controls, indicators, and fuses, are described in the manual suwith the shelf. Refer to it if you have a rackmount shelf. The rear panel of the shelf is illustratChapter 2, Figure 2-3.

Dial Backup Option

Dial Backup (DBU-89)

Dial backup may be provided by the DBU-89 Card which is factory installed onto the DataC9600R. It operates as a slave to the unit. The DBU-89 provides point-to-point operation ove2-wire switched network lines. It transmits and receives data at 9600 bps with Trellis Encodin4800 bps without Trellis Encoding. The DBU-89 allows full-duplex operation over all terrestrlinks and double hop satellite circuits.

Configuration and control of the DBU-89 Dial Back-Up Card are performed by the IFP ControInstructions covering configuration and control of the DBU-89 are provided in Chapter 5, Intelligent Front Panel .

DBU-89 Diagnostics

The DBU-89 Dial Backup Card supports a unique set of diagnostics described below. Certaiare performed using only the basecard without active participation of the DBU-89.

DBU-89 Self-Test - This test causes the DBU-89 to loopback its analog interface and run a teverify its operation. This test may be run while on the private line or switched network. If theis run while on the private line, it is noninterfering. If the test is run while on the switched netwthe call will terminate.

CRAFT Jack Female jack used by the IFP to configure, test or troubleshoot non IFP 9600R units.(This port does not support VT100 terminal.)

DIAL Button Press to manually send a dialing command. (Only with optional DBU backup on 9600R.)

NORM/TEST

3-Position Switch

OFF - center positionTEST - one push turns on a 511 self-test generator/receiver and analoop. TEST OK indicator lights and flashes off to indicate errors. NORM indicator is off. (Even if the switch is not pushed a second time, the unit is preprogrammed to drop into analoop for a measured interval, then automatically return to the normal position.)NORM - one push returns the data set to normal operation.

Note Once the dial backup is initiated because of lease line failure, it will remain engaged until the operamanually drops the call through the IFP menu or by momentary disruption of the switch network contion.

Table 3-1 DataComm 9600R Front Panel (Continued)

ID Type Action

(Sheet 2 of 2)

3-2 DataComm 9600R 058R467-000Installation and Operation Issue 1

Page 23: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Operation Special Considerations for Use with RPA Units

et laces ering

th call if d with sed

ese

ted.

R/IFP be o a

Modem Self-Test - When the IFP initiated modem self-test is performed on the 9600R data sequipped with a DBU-89, the DBU-89 does not participate in the test. The modem self-test pthe private line modem in loopback and verifies the private line data pump. This test is interfwhether the modem is on the private line or switched network.

Front Panel (Dataset) Test - This test is run from the Data Set's front panel switch. It tests bothe DBU-89 and the base card. This test is interfering on the private line and terminates thethe data set is in dial backup. The DBU dial button is not available on the 9600R/IFP equippeDBU-89. To manually force a DBU on a 9600R/IFP with DBU, you must disconnect the lealine cable.

Special Considerations for Use with RPA UnitsThe DataComm 9600R modems are compatible with existing 9600RPAs. However, using thmodels together in a network requires some special considerations.

• Point-to-Point application between a 9600R or 9600R/IFP and a 9600RPA is not suppor

• Multi-Point is supported with a 9600R/IFP as the master. Remotes can be 9600R, 9600or 9600RPA units. If the multi-point network has a combination of RPAs and non-RPAs,sure all the RPA units have RTS OFF whenever the 9600R/IFP is attempting to attach tremote 9600R using the VF. RTS must also be OFF on all RPAs to perform an ACE Calibration. Also, 9600RPAs must be optioned for 19.5 ms Training Sequence and the 9600R/IFPs must be optioned for a 9600 Mode Template.

058R467-000 DataComm 9600R 3-3Issue 1 Installation and Operation

Page 24: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Operation Special Considerations for Use with RPA Units

3-4 DataComm 9600R 058R467-000Installation and Operation Issue 1

Page 25: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

ront re also edure

he achine,

.

ated uring

Chapter 4: Tests

OverviewThis section describes the tests that may be performed on the DataComm 9600R from the fpanel after installation or whenever operation of the modem must be checked. These tests aused to isolate problems in the data communications system (refer to the fault-isolation procin Figure 4-1).

Figure 4-1 Fault Isolation Procedure

Analoop with Self-TestOne push of the switch checks the local modem while most of its circuits are isolated from ttelephone line. It uses an internal test pattern generator and detector, instead of a business mto originate and monitor tests signals. The TEST OK indicator is lit, and flashes to indicate errorsThe NORM indicator remains off.

Note The DataComm 9600R modem may be performance tested in two ways. Tests can be initifrom the IFP or front panel of the modem using the Norm /Test switch. Use of these tests dinstallation of the communications network, after installation of the unit, or following repair allows you to isolate problems in the system.

START

PROBLEMEXISTS

ANALOG LOOPBACKWITH SELF-TEST ON

LOCAL MODEM

PERFORM

PASSORFAIL

PERFORM ANALOG LOOPBACK TEST

ON LOCAL MODEM

LOCAL MODEMIS DEFECTIVE

FAULT DETECTED INCOMMUNICATION LINK

LOCAL DTE

CABLING IS DEFECTIVEOR DTE-MODEM

NOEXIT

YES

PASS

PASS FAIL

FAIL

058R467-000 DataComm 9600R 4-1Issue 1 Installation and Operation

Page 26: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Tests Analoop with Self-Test

m the message

Figure 4-2 Analoop with Self-Test

A second push of the switch checks the local modem while most of its circuits are isolated frotelephone line. The business machine is used to generate a test message and to receive thelooped back through the modem. The TEST OK indicator goes off, and the NORM indicator starts to flash. The test may be cancelled by pushing the switch to the NORM position, or by an IFP command initiated by the operator.

Modem transmitter

Modem receiver

Send data

Received data

DTECommunications line

Local loopback

Test PatternGenerator

Test PatternRecognizer

DC9600RSD RD TRRS CS CO NORM DBUCRAFT SQ

TESTOK CO DATA RESP TEST

NORM TESTMODEM

Engage Test SwitchTest OK Indicator LightsNorm Indicator Remains Off

14 DB Attenuator

MANAGEMENT

4-2 DataComm 9600R 058R467-000Installation and Operation Issue 1

Page 27: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Tests Analoop with Self-Test

One push to the NORM position returns the modem to normal operation.

Figure 4-3 Analoop

Transmitter

ReceiverDTE

VF lineHELLO

DC9600RSD RD TRRS CS CO NORM DBUCRAFT SQ

TESTOK CO DATA RESP TEST

NORM TESTMODEM

1. Engage test switch a second time

2. Test OK indicator goes off, andthe NORM indicator starts to flash

9 DB Attenuator

4. To end the test, push switch to NORMposition, or use MANAGEMENT command

DC9600R

3. Enter a test message at the terminal.the terminal should print out an accurate copy of the test message;if not, a problem may exist.

MANAGEMENT

058R467-000 DataComm 9600R 4-3Issue 1 Installation and Operation

Page 28: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Tests Analoop with Self-Test

4-4 DataComm 9600R 058R467-000Installation and Operation Issue 1

Page 29: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

duct ntroller omm

s well

h other FP 00R

Chapter 5: Intelligent Front Panel

Intelligent Front Panel (IFP) DescriptionThe Intelligent Front Panel (IFP) is factory installed on the DataComm 9600R/IFP Modem proas an alternative, not as a replacement for the existing standard front panel. The IFP is a cofor small networks. At least one IFP must be present in a network to command other DataC9600R Modems to perform configuration, diagnostics, control and maintenance functions, aas monitor alarms and status conditions.

The Liquid Crystal Display (LCD) is comprised of two lines of 16-characters each. The fourmomentary pushbutton function keys are used to operate the IFP. Serial communications witDataComm 9600R or 9600R/IFP Modems is accomplished using the front panel jack. All ILEDs, as well as the test switch, are identical to those used on the standard DataComm 96Modems and operate in the same manner (see Chapter 3, Operation , Table 3-1). The IFP is illustrated below.

The part numbers for DataComm 9600R Modems equipped with the IFP are listed in Appendix B, Equipment List. Technical characteristics are listed in Appendix A, Technical Characteristics.

Table 5-1 Intelligent Front Panel for DataComm 9600R

ID Type Action

CRAFT Jack Female jack that accepts the IFP cable.(This port does not accept VT100 terminal.)

ESC Function Key (escape) Key used to exit any level and return to the previous level.

SEL Function Key (select) Key used to step vertically downward into various sub-menu levels, with each new level being more specific than the previous one.

PREV Function Key (previous) Key used to scroll back to the previous selection.

NEXT Function Key Key used to scroll forward to the next selection.

DC9600R SD RD TRRS CS CO NORM DBUCRAFT SQTESTOK CO DATA RESP TEST

NORM TESTMODEM

ESC PREV NEXT SEL

IFP

Liquid CrystalDisplay (LCD)

Strap for enabling or disabling password protectionlocated on pc board in rear of IFP at this location

MANAGEMENT

DIS EN

058R467-000 DataComm 9600R / 9600R/IFP 5-1Issue 1 Installation and Operation

Page 30: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Installation, Operation and Testing

omm

is

s are

u to

hrough screen

er or ost or

the ich

the card er IFP.

Installation, Operation and Testing

With the exception of the IFP operation described herein, installation and testing of the DataC9600R/IFP Modems (using the NORM/TEST switch) is the same as that described for the DataComm 9600R Modem with the standard front panel. Refer to Chapters 2, 3 and 4 of thmanual to install, operate and test the DataComm 9600R/IFP Modem.

Keypad Operation

The Intelligent Front Panel (IFP) is controlled using the four function keys. The test commandgenerated from routines which are selected by using these keys. (See Table 5-1 for illustration of the function keys.)

The IFP requests information through short English-language menu prompts which allow yospecify the information necessary to complete the step.

If a question or prompt has several possible answers, all choices are accessible by scrolling tthe choices using either the PREV or NEXT keys. To make a selection, select the appropriateby pressing the SEL key.

IFP Operation

The IFP is used for configuration, control, diagnostics, maintenance and monitoring of mastremote DC9600R modems in a data communications network. With the IFP attached to a hmodem, it is used as a portable front-panel interface to DC9600R units of the same family ftesting, troubleshooting and configuration.

Configuration information is uploaded to the IFP from the selected unit, or is downloaded tounit from the IFP. The configuration routines allow you to display or modify configurations whare accessible at the IFP. This information includes (when applicable) modem options, alarmthresholds, alarm masks, and dial backup options.

General operation of the IFP employs the use of a special reversed cable. Using this cable,DataComm 9600R Intelligent Front Panel can be connected to the front panel of the single DC9600R unit, or it can be used to allow communication between the host modem and anothThe illustration below shows the Intelligent Front Panel cable.

Figure 5-1 Intelligent Front Panel Cable (GDC Part No. 830-062-001)

6 feet

GND 1 1 GND

TXD 2 2 TXD

RXD 3 3 RXD

PLUG PLUGBLK

GRN

RED

5-2 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 31: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Installation, Operation and Testing

our

)

GeDC

E

DH

DF

Overall IFP Level Structure

The following illustration shows the flow of options available through the IFP. By using the ffunction keys on the front panel, you can easily move from one option to another.

Figure 5-2 Overall IFP Level Structure

Note Optional screen - Only displays if password feature is enabled. (See illustration with Table 5-1.

Optional screen - Only displays if DBU-89 is installed.Optional screen - Only displays if Modify Mode is enabled. Optional screen - Only displays if unit is in Fake Master mode.n = 0 to 9.Optional screen - Only displays if 9600R Receive Carrier is constant.

neral DataComm 9600R / 9600R/IFP

LOG ON YES

NGAGE

EVICEOST

ATTACH

ATTACH VIA ADDRESS

ATTACH VIA SERIAL NO.

EVICEP JACK (CRAFT)

CONFIGURATION MONITOR

OP MODE TEMPLATE

MODEM

DBU-89 OPTIONS

GLOBAL ALM MASK CONTROL

DISCRETEALARM MASKS

OPTIONS

ALARMTHRESHOLD

COPY CONFIGVIA FP JACK (CRAFT)

COPY CONFIGVIA BACK CHAN

EIA STATUS

MODEM STATUS

ALARM SCAN

CLEAR

VF LEVELS

SNR & NLD LEVELS

DIAGNOSTICS

MODEM SELF-TEST

DBU-89 SELF-TEST

DATALOOPTEST

END-TO-ENDSELF-TEST

MAINTENANCE

WHAT ARE YOU

FRONT PANELCONTROL

SOFTWARE RESET

ERASE CONFIGURATION

ASSIGN ADDRESS

ACECALIBRATION

RESTORAL

MODEM CONTROL

MODEMFALLBACK

DBU-89 CONTROL

DBU-89 DIAL CELL

DBU-89 TERMINATE CALL

DBU-89 CALL PROGRESS

DBU-89 PASSWORD

DBU-89 DIRECTORY

DBU-89 CELL n

1

2

3

4

6

5

2

2

32

2

32

3

3

3

3

3

3

3

3

3

3

3ALARMS

2

3

2

6

4

4

FRC Fake Master ESC=NO SEL=YES

4

4

4

1

2

3

4

5

6

058R467-000 DataComm 9600R / 9600R/IFP 5-3Issue 1 Installation and Operation

Page 32: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Installation, Operation and Testing

e menu M he r, the urrent lash the been ut

Changing Parameters

To change a parameter from a list of valid selections, such as Data Rate, proceed through thby pressing SEL to the appropriate user prompts, which include CONFIGURATION, MODEOPTIONS and then DATA RATE. This will display a screen with the option DATA RATE on ttop row and the current parameter, say 9600 S on the bottom row. To change this parameteSEL key must be pressed again to let the IFP know that you want to change the displayed cvalue. Once the SEL key has been pressed, the parameter on the bottom row will begin to findicating that the displayed value can now be changed from the original. To cycle through possible parameter settings, press either the PREV or NEXT key. Once the new value has displayed, press the SEL key to enter the new value, or ESC to exit the change mode withochanging the value. (See Figure 5-3. )

Figure 5-3 Example of Change Parameter Routine

COMPATIBILITY9600R MODE

DATA RATE9600 S

AAS TIMERINHIBIT

CTS DELAYCTS ON

DATA RATE9600 S

DATA RATE9600 A

SEL

PREVPREV

NEXT

.

.

.

NEXT

5-4 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 33: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Installation, Operation and Testing

nce

split cases

edit, or

some s are e set. cursor

derline go if top

the e the

ithout

rsor Press

Certain routines require the entry of a string of numbers or characters to be stored as refereinformation for the IFP operator. The string entry parameter sequence is shown in Figure 5-4.

Figure 5-4 String Entry Parameter Sequence

The following procedure is used to enter a string. Upon entering this level, the screen will beinto two fields. The parameter field (top row) contains the parameter to be edited or entered. Inwhere the parameter field exceeds 16 characters, scroll the parameter field in order to view, modify the entire parameter.

The choice field (bottom row) contains a set of 10 parameter choices plus an END choice. Incases, parameter choices are alphanumeric. However, in most cases, the parameter choicenumeric only. In either case, the parameter choice row always defaults to the numeric choicUse the PREV/NEXT keys to view the alternate parameter sets by pressing PREV when theunderline is at zero or NEXT when the cursor underline is at END.

One row contains an underline marker and the other row contains a flashing marker. The unposition is where the cursor is currently located. The flashing position is where the cursor willtoggled to the other row. The ESC (escape) key is used to toggle from the bottom row to therow; the SEL key is used to toggle from the top row to the bottom row (see Figure 5-5D). In the top row, use the PREV/NEXT keys to select the position to be modified. In the bottom row, use PREV/NEXT keys to select the new digit to enter. In the bottom row, use the SEL key to movchoice into the parameter at the marked position (see Figure 5-5B).

To exit with a new parameter, position the cursor at the word END and press SEL. To exit wchange, press ESC from the parameter row (top row) (see Figure 5-5C).

The edit feature is shown in Figure 5-5D. To use the edit feature, press ESC once to move the cuinto the top row. Use the PREV/NEXT keys to move the cursor to the position to be changed.SEL to move the cursor back into the bottom row. Repeat the steps shown in Figure 5-5A and B for the desired results.

OPTION 107 UNITS

OPTION 204 UNITS

OPTION 399 UNITS

OPTION n120 UNITS

04 UNITS0123456789 END

SEL

PREV

.

.

.

NEXT

058R467-000 DataComm 9600R / 9600R/IFP 5-5Issue 1 Installation and Operation

Page 34: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Installation, Operation and Testing

rker

Figure 5-5 String Entry Procedures

Note The underline denotes cursor location. Bold denotes the marker position. In the actual display, the mablinks.

SEL

SEL

A. MOVING THE CURSOR TO THE DESIRED DIGIT

B. ENTERING THE NEW DIGIT(S)

SEL

C. EXIT FROM CHANGE MODE

SEL

ESC

D. EDITING

PREV PREV

NEXT NEXT

04 UNITS0123456789 END

04 UNITS0123456789 END

04 UNITS0123456789 END

04 UNITS0123456789 END

24 UNITS0123456789 END

22 UNITS0123456789 END

22 UNITS0123456789 END

OPTION n22 UNITS

007 UNITS0123456789 END

PREV PREV

NEXT NEXT

007 UNITS0123456789 END

007 UNITS0123456789 END

007 UNITS0123456789 END

007 UNITS0123456789 END

5-6 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 35: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Installation, Operation and Testing

nter

ontrol ss-y

es, in he

done

Figure 5-6 provides an illustration of an IFP display for the Diagnostic group. Press SEL to ethe group and use the PREV/NEXT keys to scroll through the choices.

Figure 5-6 Typical Diagnostic Group Display

IFP Modes Of Operation

Two modes of operation are provided by the IFP - Display and Modify.

Display mode allows you to display configuration information, monitor mode information, including status, alarm, and threshold levels, as well as restoral mode information including csettings and "What Are You" routine results. Display mode is automatically entered if the paword option is enabled and you bypass the LOGON. In display mode you cannot change anoptions.

Modify mode optionally requires the use of a password. It allows you to modify configurationinformation, and perform diagnostic tests, control routines, and additional maintenance routinaddition to providing all the capabilities of the display mode. The modify mode is entered if tpassword option is disabled, or if the password option is enabled and you enter the correct password.

The IFP must gain diagnostic control of the unit before any functions can be performed. This iswhen the engage function is selected.

ENGAGE

ATTACH

CONFIGURATION

MONITOR

DIAGNOSTICS

MAINTENANCE

RESTORAL

DBU-89 DIRECTORY

MODEMSELF-TESTDBU-89SELF-TEST

DATALOOP TEST

END-TO-ENDSELF-TEST

GROUP LEVEL SUB-GROUP LEVEL

NEXT P

REV

*

*

*

*

*

*

*

* OPTIONAL SCREEN - SEE Figure 5-2

058R467-000 DataComm 9600R / 9600R/IFP 5-7Issue 1 Installation and Operation

Page 36: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Installation, Operation and Testing

nit, ration using. ed on

ly

ck by

he to the

e, the

am of ed unit r.

/IFP

Intelligent Pointer Feature

A powerful feature of the IFP is the intelligent pointer. Using information obtained from the uthe intelligent pointer skips unneccesary information screens. This feature simplifies IFP opesince it prevents the system from displaying irrelevant options or features which may be confThe intelligent pointer is automatically employed in all modes of operation with decisions basthe following information.

Gaining Access To A Unit

There are three ways to gain access to a unit, as follows:

• The IFP can communicate with the Host unit (DataComm 9600R) on which it is physicalmounted when you select HOST in response to the ENGAGE prompt.

• The IFP can communicate with another DataComm 9600R Modem via the front panel jaconnecting a special cable (see Figure 5-1) between the two units and selecting FP JACK inresponse to the ENGAGE prompt.

• The IFP can communicate with any DataComm 9600R remote via the secondary channel of tengaged unit provided that the correct address or serial number is entered in response ATTACH prompt.

A successful engagement is a prerequisite for communication with any 9600R unit. ThereforIFP will not allow access to any other menu functions until the engage function is complete.

The attach function allows communication with any remote DataComm 9600R unit downstrethe engaged unit, provided that either the address or serial number is known and the engagis set to fake master. (See Option Selection section in Chapter 2 for location of serial numbe

Table 5-2 Intelligent Pointer Features

Synchronous/Asynchronous 9600R

Master/Remote TX Constant Carrier/Switched CarrierRX Constant Carrier/Switched Carrier

Display/Modify Password Enabled/Password Disabled

DBU Installed/None Engaged/Disengaged

DBU-89

Note Say YES to FRC Fake Master only if you need to communicate to a remote 9600R or 9600Rthrough the VF, or if you are going to perform an ACE Calibration.

5-8 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 37: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

ys of the ral utines

ed to e creen,

. If the isabled,

ted on

Operating RoutinesThis section describes the IFP level structure, and provides samples of typical screen displawithin each level. Information in this section is organized according to the menu organization operator interface. Routines are listed in the same order as they appear in each level. Geneinformation about each level is followed by specific reference paragraphs that describe the rothat make UP that level. The top level-structure is shown in Figure 5-7. Refer to Appendix B for a complete listing of the IFP level structure sequence.

Figure 5-7 IFP Level Structure

Product Level

IFP flow always begins at the product level. This level contains an information screen referras the product level screen which will display GENERAL DATACOMM in the top row and thproduct name of the host unit (DataComm 9600R/IFP) in the bottom row. The product level Sshown in Figure 5-8 is always the first screen to be displayed upon power-up.

Figure 5-8 Product Level Screen

Pressing SEL is the only key that will start the menu structure. All other keys are disregardedpassword feature is enabled, the next level is the password level. If the password feature is dthe next level is the group level.

The password feature is physically enabled or disabled by positioning the Berg jumper locathe pc board at the rear of the IFP (see the illustration with Table 5-1).

PRODUCT LEVEL PASSWORD LEVEL OPTION/FUNCTION LEVELSUB-GROUP LEVELGROUP LEVEL

..

.

..

.

..

.

SELESC

NEXT

PREV

LOWEST LEVELHIGHEST LEVEL

GENERAL DATACOMM9600R/IFP

058R467-000 DataComm 9600R / 9600R/IFP 5-9Issue 1 Installation and Operation

Page 38: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

ia the rd

ck and

reen

he fy and

ature nute bled if

Transparent Mode

When using an DataComm 9600R/IFP unit to engage another DataComm 9600R/IFP unit vfront panel jack cable, the unit to be engaged must perform in the same manner as a standaDataComm 9600R unit. Therefore, the IFP on the DataComm 9600R unit must operate transparently so as not to interfere with the data being transferred between the front panel jathe DataComm 9600R. The transparent mode is entered by disengaging the IFP from the DataComm 9600R. This is accomplished by pressing the ESC key until the product level scappears.

Password Level

When the password is enabled, the Password level displays by pressing the SEL key after tProduct Level (top screen) is displayed. The password level routine controls entry to the modidisplay modes of operation.

Inactivity Timeout Security Feature

The inactivity timeout feature is used in conjunction with the Password enable mode. This femonitors the keys for a 15-minute period of inactivity. If no activity is detected within the 15-miperiod, the IFP automatically reverts to the top level screen and logs out. This feature is disathe password disabled mode is selected.

PRODUCT LEVEL PASSWORD LEVEL

GENERAL DATACOMM9600R/IFP

GENERAL DATACOMM9600R/IFP

PRODUCT LEVEL GROUP LEVEL

ENGAGE

LOG ONYES

LOG ONNO

SELESC

SELESC

NE

XT

PR

EV

ENABLED

DISABLED

5-10 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 39: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

LOG r a

tion

, then e

will

Log On

At the top of the password level, press either the PREV or NEXT key to toggle between theON YES or NO options. To enter the modify mode, you must select LOG ON YES and entecorrect password. If LOG ON NO is selected, you automatically go into display mode.

The password is the last four digits in the serial number of the base unit. (See Option Selecsection in Chapter 2 for location of serial number.) The password level routine is shown in Figure 5-9.

To build the password, position the cursor in the bottom row to the first digit in the passwordpress SEL. This moves the value of the cursor to the top row. Continue this process until thpassword is built. To enter the password, move the bottom cursor to END and press SEL.

If the password is accepted, the IFP will respond with PASSWORD ACCEPTED and the IFPenter the modify mode. If the Password is rejected, the IFP will respond with PASSWORD REJECTED and will return to the LOG ON prompt.

Figure 5-9 Password Level Routine

LOG ONYES

* * * *0123456789 END

PASSWORDREJECTED

50130123456789 END

LOG ONYES

SEE FIGURE 5-5

END

SEL ESC

INPUT SCREEN

INPUT SCREEN

ENTERS MODIFY MODE

058R467-000 DataComm 9600R / 9600R/IFP 5-11Issue 1 Installation and Operation

Page 40: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

is is

s not u can. sly, you

lowing

eys to nction.

Once

, or if the

Engage

To communicate with any unit, the IFP must first obtain control of the diagnostic source. Thaccomplished through a process called engaging.

The engage routine provides the IFP with an address used for communication. If the IFP haengaged, the LCD routine will not proceed any further until the engage routine is selected. Yoat this time, escape to the top screen by pressing the ESC key. If you have engaged previoumay choose to scroll past this group member using the PREV or NEXT keys.

To engage, follow the routine described in Figure 5-10.

Figure 5-10 Engage Level Sequence

Once the engage function has been selected, you have the option of scrolling through the foltwo choices using the PREV or NEXT keys.

• HOST (the unit on which the IFP is physically mounted)

• FP JACK (CRAFT) (the unit at the opposite end of the Jack-to-Jack cable)

To engage a unit, press SEL in response to the ENGAGE prompt. Use the NEXT or PREV kchoose between the HOST and FP JACK selections, then press SEL to initiate the engage fu

If HOST is selected the IFP will flash the word engaging while communication is established. connected, the IFP will read FRC FAKE MASTER ESC=NO SEL=YES. Say YES to FAKE MASTER only if you need to communicate to a remote 9600R or 9600R/IFP through the VFyou are going to perform an ACE Calibration. Once your choice is made, the IFP will displayaddress of the unit it is engaged to.

ENGAGE

ATTACH

CONFIGURATION

MONITOR

DIAGNOSTICS

MAINTENANCE

RESTORAL

DBU-89 DIRECTORY

GROUP LEVEL

* OPTIONAL SCREEN - SEE

*

*

*

*

*

SUB-GROUP LEVEL

DEVICEHOSTDEVICEFP JACK

NE

XT

PR

EV

SELESC

Figure 5-2

5-12 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 41: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

aking

ey to ttach der the ING

ew ED

ntering

ake

must

If FP JACK (CRAFT) is to be selected, the cable needs to be attached to both units before mthe selection or you will get a message telling you the cable is not installed.

Attach

The attach level is entered using the sequence shown in Figure 5-11. It allows you to change the communication address to another unit across the VF line.

Figure 5-11 Attach Level Sequence

To attach to a unit, press SEL in response to the ATTACH prompt. Use the NEXT or PREV kdisplay the ADDRESS or SERIAL NUMBER prompt, then press SEL to choose the desired amethod. Enter the serial number or address, then use the NEXT key to position the cursor unword END and press SEL to begin the attach process. The IFP will flash the word ATTACHwhile communication with the new unit is established.

If attach is successful, the IFP displays ATTACHED TO LINE XXX DROP XX which is the nworking address for the IFP. If the attach is not successful, the IFP displays, ATTACH FAILESC=ABT SEL=RTRY.

If ATTACH fails, verify that the RX levels are not too hot and the units have passed ACE Calibration.

You can change the communication address by either changing the line/drop address or by ethe serial number of the modem that you want the IFP to communicate with.

Note If units are connected via the network and the FP JACK (CRAFT) is selected for configuration as a FMaster, you must power cycle the remote unit before it can be managed by the Master IFP.

Note To successfully attach to a remote DataComm 9600R IFP unit, the remote DataComm 9600R /IFP display the product level screen.

ENGAGE

ATTACH

CONFIGURATION

MONITOR

DIAGNOSTICS

MAINTENANCE

RESTORAL

DBU-89 DIRECTORY

GROUP LEVEL

* OPTIONAL SCREEN - SEE

*

*

*

*

*

SUB-GROUP LEVEL

ATTACH VIAADDRESSATTACH VIASERIAL NUMBER

NE

XT

PR

EV

SELESC

Figure 5-2

058R467-000 DataComm 9600R / 9600R/IFP 5-13Issue 1 Installation and Operation

Page 42: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

As an example, ATTACH VIA SERIAL NUMBER is shown in Figure 5-12.

Figure 5-12 Attach Level Selections

ATTACH

ATTACH VIASERIAL NUMBER

00000000000000000123456789 END

ATTACHING

SEL

SEL

SEL

5-14 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 43: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

isplay, e is d nit to

ed are ot be

nit to

EXT y

Configuration

The configuration group level is entered in the sequence shown in Figure 5-13.

This group has two modes of operation; display mode, and modify mode. Display mode is automatically selected when a password is required and not entered. In this mode, you can dbut not modify the configuration of the unit to which the IFP is currently attached. Modify modautomatically selected when a password is not required, or when a password is required ancorrectly entered. In this mode, the user can display and/or modify the configuration of the uwhich the IFP is currently attached.

All configuration screens are accessible in modify mode. In display mode, the screens displaylimited to those pertaining to display mode only. Screens pertaining to modify mode only cannviewed.

Figure 5-13 Configuration Sequence

Operating Mode Template

In the modify only mode, the Operating Mode Template subgroup is used to configure the uone of the default configurations in Table 5-3.

To enter this mode, press SEL in response to OP MODE TEMPLATE. Using the PREV or Nkey, you may scroll through the choices shown in Table 5-3. To select a template, use the SEL keand the IFP will respond COMPLETE.

ENGAGE

ATTACH

CONFIGURATION

MONITOR

DIAGNOSTICS

MAINTENANCE

RESTORAL

DBU-89 DIRECTORY

*

*

OPERATING MODETEMPLATEMODEMOPTIONS

SELESC

*

*

*

* OPTIONAL SCREEN - SEE

GROUP LEVEL SUB-GROUP LEVEL

DBU-89OPTIONSGLOBAL ALARMMASK CONTROLDISCRETE ALARMMASKS

ALARM THRESHOLD

COPY CONFIGVIA FP JACKCOPY CONFIGVIA BACK CHANNEL*

*

*

NE

XT

PR

EV

Figure 5-2

058R467-000 DataComm 9600R / 9600R/IFP 5-15Issue 1 Installation and Operation

Page 44: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

Table 5-3 Operating Mode Template Choices

9600R Template Names

Option

ModeData Type

TX Carrier Type

RX Carrier Type

CTS Option

Line Break

Holdover

Signal Qual

Round Robin

Train on Data

FastS PT - PT MST(FastS Point-to-Point Master)

96R SYNC CONSTANT CONSTANT ON INHIBIT ENABLE INHIBIT

FastS PT - PT RMT(FastS Point-to-Point Remote)

96R SYNC CONSTANT CONSTANT ON INHIBIT ENABLE INHIBIT

FastS MLT - PT MST(FastS Multi-Point Master)

96R SYNC CONSTANT SWITCHED ON INHIBIT INHIBIT ENABLE

FastS MLT - PT RMT(FastS Multi-Point Remote)

96R SYNC SWITCHED CONSTANT 10 ms ENABLE INHIBIT ENABLE

FastA PT - PT MST(FastA Point-to-Point Master)

96R ASYNC CONSTANT CONSTANT ON INHIBIT ENABLE INHIBIT

FastA PT - PT RMT(FastA Point-to-Point Remote)

96R ASYNC CONSTANT CONSTANT ON INHIBIT ENABLE INHIBIT

FastA MLT - PT MST(FastA Multi-Point Master)

96R ASYNC CONSTANT SWITCHED ON INHIBIT INHIBIT ENABLE

FastA MLT - PT RMT(FastA Multi-Point Remote)

96R ASYNC SWITCHED CONSTANT 10 ms ENABLE INHIBIT ENABLE

9600-S PT - PT MST(9600-S Point-to-Point Master)

96 SYNC CONSTANT CONSTANT ON INHIBIT ENABLE INHIBIT

9600-S PT - PT RMT(9600-S Point-to-Point Remote)

96 SYNC CONSTANT CONSTANT ON INHIBIT ENABLE INHIBIT

9600-S MLT - PT MST(9600-S Multi-Point Master)

96 SYNC CONSTANT SWITCHED ON INHIBIT INHIBIT ENABLE

9600-S MLT - PT RMT(9600-S Multi-Point Remote)

96 SYNC SWITCHED CONSTANT 19 ms ENABLE INHIBIT ENABLE

9600-A PT - PT MST(9600-A Point-to-Point Master)

96 ASYNC CONSTANT CONSTANT ON INHIBIT ENABLE INHIBIT

9600-A PT - PT RMT(9600-A Point-to-Point Remote)

96 ASYNC CONSTANT CONSTANT ON INHIBIT ENABLE INHIBIT

9600-A MLT - PT MST(9600-A Multi-Point Master)

96 ASYNC CONSTANT SWITCHED ON INHIBIT INHIBIT ENABLE

9600-A MLT - PT RMT(9600-A Multi-Point Remote)

96 ASYNC SWITCHED CONSTANT 19 ms ENABLE INHIBIT ENABLE

5-16 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 45: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

ion XT e

00R

vels

Modem Options

Pressing SEL in response to MODEM OPTIONS will cause the IFP to load the following optinformation into memory. You may scroll through this information by pressing the PREV or NEkey. Options will remain in the nonvolatile memory if you choose to save the selections at thprompt. The list of options and their appropriate choices as pertaining to the DataComm 96Modem are shown in Table 5-4.

Table 5-4 Modem Options (factory defaults in bold )

Modem Options Choices

DATA RATE (DATA TYPE) 9600-S (Synchronous), 9600-A (Asynchronous)

COMPATABILITY 96, 96R

AAS TIMER INHIBIT, 5 SEC, 10 SEC, 30 SEC, 45 SEC

CTS DELAY (CONSTANT) CTS ON, 00 ms, 08 ms, 15 ms

CTS DELAY (SWITCHED)(Read only option)

10 ms (for 96R Compatability)19 ms (for 96 Compatability)

TX CARRIER SWITCHED, CONSTANT

RX CARRIER SWITCHED, CONSTANT

TIMING INTERNAL , EXTERNAL, RECEIVE

DSR ON, FOLLOWS DTR

LN BRK HOLDOVER ENABLE, INHIBIT

ANALOOP DSR NORMAL, OFF

TRAIN ON DATA ENABLE , DISABLE

PL TX LEVEL (see note) +00 db TO -15 db (in 1 db increments)

SQM ROUND ROBIN DISABLE , ENABLE

RTS/CTS EXT 00 ms , 20 ms, 40 ms, 90 ms

WORD SIZE (Asynchronous only) 11 BITS, 8 BITS, 9 BITS, 10 BITS

SPEED ADJUST (Asynchronous only) 1 .25%, 2.50%

SUPPRESSION (Asynchronous only) INHIBIT, TX EOT, RX EOT, TX & RX EOT

Note For back-to-back bench test, or applications where RX could be hotter than -12dB, the TX leof both units should be adjusted in such a way that RX levels are about -15dB.

058R467-000 DataComm 9600R / 9600R/IFP 5-17Issue 1 Installation and Operation

Page 46: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

on XT odem

tly

the

DBU-89 Options

Pressing SEL in response to DBU-89 OPTIONS will cause the IFP to load the following optiinformation into memory. You may scroll through this information by pressing the PREV or NEkey. The list of options and the applicable choices as pertaining to the DataComm 9600R Mwith DBU-89 are shown in Table 5-5.

Global Alarm Mask Control

The Global Alarm Mask Control subgroup is available in modify mode only. It enables you tocontrol the alarm masks globally. That is, to enable or disable all alarm masks of the currenattached unit at once as shown in Table 5-6. The IFP will respond "COMPLETE" following your selection.

Note The following group appears in the Configuration group list, only when a DBU-89 card is installed onDataComm 9600R Modem's base card.

Table 5-5 DBU-89 Option Choices (factory defaults in bold )

DBU-89 Options Choices

DBU MODE DBU-89

DBU DATA RATE 4.8K, 9.6K

DBU TX CARRIER CONSTANT, SWITCHED

DBU RX CARRIER CONSTANT, SWITCHED

DBU TIMING INTERNAL , EXTERNAL, RECEIVE

DBU CTS OPTION CTS ON, Use Delay Value

DBU CTS DELAY 10ms - 250ms (resolution in increments of 10)

DBU RINGS TO ANSWER 0-255 (default is 1)(Do not option to answer on zero (0) rings if unit is required to answer call.)

Table 5-6 Global Alarm Mask Control Choices (factory default in bold )

Global Alarm Mask Control Choices

ALL ALARMS REPORTED, MASKED

5-18 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 47: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

ble all

asks. eters

if the ask

Discrete Alarm Masks

The Discrete Alarm Masks subgroup enables you to display and/or selectively enable or disaalarm masks applicable to the DataComm 9600R.

When this subgroup is entered, the IFP constructs an image of the current modem alarm mDepending upon mode (modify or display), you will be able to change and/or view the paramin the image. Upon exiting the Alarm Mask subgroup, the IFP prompts you to save changesimage was modified. To save the changes, the IFP constructs the appropriate set of alarm mcommands using the modified image, and sends the commands to the attached unit. Table 5-7 illustrates the alarm masks and choices as applicable for the DataComm 9600R Data Set.

Table 5-7 DataComm 9600R Alarm Mask Choices (factory default in bold )

Discrete Alarm Masks Choices

DTP LOSS ALARM ENABLED , DISABLED

DTR LOSS ALARM ENABLED , DISABLED

DBU SCAN REQUEST (Only with DBU-89 card) ENABLED , DISABLED

DBU CALL FAILURE (Only with DBU-89 card) ENABLED , DISABLED

TXD LOSS ALARM ENABLED , DISABLED

TXC LOSS ALARM ENABLED , DISABLED

RXD LOSS ALARM ENABLED , DISABLED

TEST MODE ALARM ENABLED , DISABLED

EEPROM ALARM ENABLED , DISABLED

ON DBU ALARM ENABLED , DISABLED

LAST GASP ALARM ENABLED , DISABLED

STREAMING ALARM ENABLED , DISABLED

DSP LOSS ALARM ENABLED , DISABLED

EXT INPUT ON ENABLED , DISABLED

EXT INPUT CHANGE ENABLED , DISABLED

SQM ALARM ENABLED , DISABLED

RX VF LO ALARM ENABLED , DISABLED

RX VF HI ALARM ENABLED , DISABLED

PHASE JITTER ENABLED , DISABLED

IMPULSE HITS ENABLED , DISABLED

GAIN HITS ENABLED , DISABLED

PHASE HITS ENABLED , DISABLED

S/N RATlO ENABLED , DISABLED

DISTORTION ALARM ENABLED , DISABLED

DROPOUT ALARM ENABLED , DISABLED

DCD LOSS ALARM ENABLED , DISABLED

RETRAIN ALARM ENABLED , DISABLED

FREQ OFFSET ENABLED , DISABLED

REMOTE LINE LOSS ENABLED , DISABLED

SEC CH STREAMING ENABLED , DISABLED

DBU FAILURE (Only with DBU-89 card) ENABLED , DISABLED

058R467-000 DataComm 9600R / 9600R/IFP 5-19Issue 1 Installation and Operation

Page 48: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

holds.

ds to the ing on age. e was mands

R

Alarm Threshold

The Alarm Threshold subgroup enables you to display and/or selectively modify alarm thres

When this subgroup is entered, the IFP issues the appropriate read alarm threshold commanattached unit in order to construct an image of the current modem alarm thresholds. Dependthe mode, (modify or display), you will be able to change and/or view the parameters in the imUpon exiting the alarm threshold subgroup, the IFP prompts you to save changes if the imagmodified. To save the changes, the IFP constructs the appropriate set of alarm threshold comusing the modified image and sends the commands to the attached unit.

Table 5-8 illustrates the alarm thresholds and choices as applicable for the DataComm 9600Modem.

Table 5-8 DataComm 9600R Alarm Threshold Choices (factory defaults in bold )

Alarm Threshold Choices

ALRM INTEGRATION 1, 5,10, 15, minutes

IMPULSE HITS 100 to 0999 (See Note 1)

IMPULSE HITS 1 to 99 (See Notes 1)

GAIN HITS 1 to 99 (See Note 1)

PHASE HITS 1 to 99 (See Note 1)

DROP OUTS 1 to 99 (See Note 1)

RETRAINS 1 to 99 (See Note 1)

LOW LEVEL POLLS 0 to 50% (See Note 2)

POLLING QUALITY 0 to 50% (See Note 2)

VF RX LOW LEVEL -14 to -31 dBm

VF RX HI LEVEL -00 to -13 dBm (See Note 1)

RX S/N RATlO 15 to 31 dB (default 16) (See Note 1)

PHASE JITTER 0006 to 0020 (default 0020)

NON LINEAR DIST -25 to -35 dB (See Note 1)

SQ MONITOR 10e3, 10e4, 10e5, 10e6, 10e2

FREQUENCY OFFSET 1 to 9 Hz (See Note 1)

PRIMARY DCD LOSS 1 to 99 (See Note 1)

Notes 1. Option available when primary receive carrier is set to constant

2. Option available when primary receive carrier is set to switched.

5-20 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 49: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

de.

e target

ts the The ges

Copy Configuration

The copy configuration routines are performed using the following two subgroups:

• COPY CONFIG VIAFP JACK

• COPY CONFIG VIABACK CHANNEL

The first subgroup (Copy Config Via FP Jack) is only available when the IFP is in Modify Mo

The second subgroup (Copy Config Via Back Channel) is only available when the IFP is ENGAGED or ATTACHED to a master unit in the Modify Mode.

Table 5-9 lists the parameter choices for Copy Configuration Via FP Jack.

When copying via the back channel, you must specify the address of both the source and thunits. The parameter choices for copying configurations via the back channel are shown in Table 5-10.

During the copy process, the IFP solicits the source unit, reads its configuration profile, solicitarget unit, sends the configuration profile to the target unit and establishes the original link.IFP indicates which procedure it is performing by flashing one of the following interim messaduring the process.

Messages That May Display During Copy Configuration

• SOLICITING SOURCE

• SOLICITING TARGET

• READING MODEM OPTIONS

• READING DBU OPTIONS

• READING ALARM MASKS

• READING ALARM THRESHOLDS

• SENDING MODEM OPTIONS

• SENDING DBU OPTIONS

• SENDING ALARM MASKS

Table 5-9 Copy Configuration Via FP Jack

Jack-to-jack Options Choices

COPY FROM HOST TO FP JACK, FP JACK TO HOST, FP JACK TO JACK

Table 5-10 Copy Configuration Via Back Channel

Back Channel Options Choices

SRC LINE Example: 004

SRC DROP Example: 01

TGT LINE Example: 004

TGT DROP Example: 02

058R467-000 DataComm 9600R / 9600R/IFP 5-21Issue 1 Installation and Operation

Page 50: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

tifies

ure is t

ons.

fter pying ia the s to that

M:

a the t

FP target e

the n

g

ING

• SENDING ALARM THRESHOLDS

• ESTABLISHING ORIGINAL LINK

• COPY COMPLETE

The soliciting procedure concerns itself with updating the IFP's static information which identhe unit's profile, that is, MASTER/REMOTE, SYNC/ASYNC, DBU INSTALLED, etc. This procedure is executed before the reading or sending of configurations. The soliciting procedskipped if the IFP detects that the specified SOURCE or TARGET happens to be the currenEngaged or Attached unit. The soliciting procedure also includes engaging and disengagingroutines when copying configurations via the front panel jack.

The READING CONFIGURATION procedure reads in the following source unit's configurati

MODEM OPTIONSDBU OPTIONS (if DBU-89 Card is installed)ALARM MASKSALARM THRESHOLDS

During this procedure the IFP displays the current configuration being read into IFP RAM. Aall configurations have been read, the IFP will begin the second half of the copy process. If covia FP JACK, the IFP will disengage the source unit and engage the target unit. If copying vback channel, the IFP remains engaged to the current unit, but changes the working addresof the target unit.

The SENDING CONFIGURATION procedure sends the following configurations from IFP RA

MODEM OPTIONSDBU OPTIONS (if DBU-89 card is installed in both source and target units)ALARM MASKSALARM THRESHOLDS

This procedure displays the current configurations being sent to the target unit. If copying vifront panel jack, the IFP will disengage the target unit after all configurations have been senprovided the target unit was not the original unit.

The ESTABLISHING ORIGINAL LINK procedure attempts to reestablish the original link the Ihad prior to entering the copy configuration functions. If the original unit happened to be the unit, this procedure will initiate a static update to record any profile changes which may havoccurred during the copy process.

If the IFP is Engaged via the FP JACK, and a Jack-to-Jack copy configuration is attempted,ESTABLISHING ORIGINAL LINK procedure will establish the link with the unit to which thejack is currently connected. This function will also prompt to move the front panel cable whecopying Jack-to-Jack.

If there are communication conflicts with either the source or target units, one of the followinmessages will display on the screen.

Note If you abort the copy configuration function by pressing ESC, the routine will execute the ESTABLISHORIGINAL LINK routine.

5-22 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 51: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

h the

ing

With one of the above messages displayed, pressing ESC will cause the ESTABLISHING ORIGINAL LINK procedure to execute; pressing SEL will cause a retry to be attempted.

Monitor

The Monitor group provides the capability to monitor the status and alarms of the unit to whicIFP is attached. This group is entered using the sequence shown in Figure 5-14.

Figure 5-14 Monitor Sequence

During any monitor function, the IFP polls the unit to which it is attached for status and alarminformation. With each new scan, the screen is refreshed with new information.

The Monitor group is divided into four subgroups which are discussed individually in the followparagraphs.

INV SRC RESPONCEESC=ABT SEL= RTRY

INV TGT RESPONCEESC=ABT SEL=RTRY

ENGAGE

ATTACH

CONFIGURATION

MONITOR

DIAGNOSTICS

MAINTENANCE

RESTORAL

DBU-89 DIRECTORY

EIA STATUS

MODEMSTATUS

SELESC

*

*

*

* OPTIONAL SCREEN - SEE

GROUP LEVEL SUB-GROUP LEVEL

ALARM SCAN

CLEAR ALARMS

VFLEVELSSNR & NLD

*

NE

XT

PR

EV

*

LEVELS*

Figure 5-2

058R467-000 DataComm 9600R / 9600R/IFP 5-23Issue 1 Installation and Operation

Page 52: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

the orting g for

own in

tus p

nt tivity.

00R

EIA Status

This EIA Status subgroup enables you to simultaneously monitor up to eight EIA signals of currently attached unit. When reporting an ON condition, the IFP uses an up arrow. When repan OFF condition, the IFP uses a down arrow. If the line is in constant transition during pollinits status, the IFP uses an up-down arrow. A dash indicates no activity.

The EIA signals monitored by the IFP, as supported by the DataComm 9600R Modem, are shTable 5-11.

A typical EIA Status screen appears as follows:

Modem Status

The Modem Status subgroup enables you to simultaneously monitor up to eight Modem Staconditions of the currently attached unit. When reporting an ON condition, the IFP uses an uarrow. When reporting an OFF condition, the IFP uses a down arrow. If the line is in constatransition during polling for its status, the IFP uses an up-down arrow. A dash indicates no ac

The Modem Status conditions as monitored by the IFP and supported by the DataComm 96Modem are shown in Table 5-12.

Table 5-11 EIA Status Conditions

Abbreviation Description

DSR DATA SET READY

DTR DATA TERMINAL READY

RTS REQUEST TO SEND

CTS CLEAR TO SEND

DCD DATA CARRIER DETECT

SQM SIGNAL QUALITY MONITOR

TXD TRANSMIT DATA

RXD RECEIVE DATA

Table 5-12 Modem Status Conditions

Abbreviation Description

ASE ANTI-STREAMING ENABLE

MSI MODEM STREAMING ENABLE

FPE FRONT PANEL ENABLE

TST TEST

MIH MODEM INHIBIT

DBU DIAL BACKUP

FLB FALLBACK

DSR

DCD

DTR RTS CTS

SQM TXD RXD --

5-24 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 53: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

alarms ay r

the last ing

d and itoring

A typical Modem Status screen appears as follows.

Alarm Scan

When monitoring alarms, the IFP will scan the attached unit and update the screen with new occurring since the last scan. Upon entering the Alarm Scan subgroup, the screen will displALARMS ACTIVE XX, which indicates the number of active alarms. AS long as XX is greatethan 0, you can suspend scanning at any time and display the alarms which were caught in scan. This can be done by pressing SEL. You may scroll through all active alarms by pressPREV or NEXT.

As part of the alarm scan, the IFP monitors DBU-89 basecard alarms. If a DBU-89 is installehas an active alarm, it generates a DBU Scan Request Alarm. The IFP does not support monof specific DBU-89 alarms.

A typical Alarm Scan screen appears as follows.

Table Table 5-13 lists the types of alarms that display on the screen during the alarm scan.

Note Masked alarms are not reported. See Table 5-6 and Table 5-7.

Table 5-13 Displayed Alarms During Alarm Scan

DTP Loss Alarm Streaming Alarm Phase Jitter

DTR LOSS ALARM DSP LOSS ALARM IMPULSE HITS

DBU SCAN REQUEST DCD LOSS ALARM GAIN HITS

DBU CALL FAILURE FREQ OFFSET PHASE HITS

TXD LOSS ALARM SEC CH STREAMING S/N RATlO

RXD LOSS ALARM EXT INPUT ON DISTORTION ALARM

TEST MODE ALARM EXT INPUT CHANGE DROPOUT ALARM

EEPROM ALARM SQM ALARM RETRAIN ALARM

ON DBU ALARM RX VF LO ALARM REMOTE LINE LOSS

LAST GASP ALARM RX VF HI ALARM DBU FAILURE

ASE

MIH

MSI FPE TST

DBU FLB

ALARMS ALIVE

003

058R467-000 DataComm 9600R / 9600R/IFP 5-25Issue 1 Installation and Operation

Page 54: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

te. The

r the xt will

al-to-level

Clear Alarms

The Clear Alarms sub-group clears latched alarms in the attached unit. Press SEL to execuunit responds "COMPLETE". Table 5-14 shows the Clear Alarm choices.

VF Levels

When configured for constant carrier operation, the VF level sub-group allows you to monitotransmit and receive VF levels on the currently engaged or attached unit. The receive level teflash if a receive level alarm is active indicating that the current receive level exceeds the programmed threshold limit. For example, the screen will display:

SNR & NLD Levels

When configured for constant carrier operation, this sub-group allows you to monitor the signnoise ratio and non-linear distortion levels on the currently engaged or attached unit. Either will flash if its corresponding alarm is active. For example, the screen will display:

Table 5-14 Clear Alarm Choices

Clear Alarms Choices

CLEAR ALARMS ON UNIT, DBU-89, UNIT & DBU-89

RX LEVEL -43 dBmTX LEVEL -09 dBm

SNR LEVEL -35 dBNLD LEVEL -00 dB

5-26 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 55: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

p,

odify red and

ill be XT

drop pts you L in

ermore, nd test

ered a

be

Diagnostics

The Diagnostics group provides the capability to perform diagnostic tests. To enter this groufollow the sequence shown in Figure 5-15.

Figure 5-15 Diagnostics Sequence

The diagnostic tests supported by the IFP are "interfering", that is they temporarily disrupt communications. Because of this, diagnostics are only available during the modify mode. Mmode is automatically selected when a password is not required, or when a password is requientered correctly.

Once you have pressed SEL in response to the Diagnostics prompt, up to four test modes waccessible. You can scroll through the test mode options by pressing either the PREV or NEkeys. To initiate a test, you press SEL in response to the test displayed on the screen.

If the test selected is an end-to-end type test, the IFP will prompt you for the target line and address for the test. Once the information is entered, and before any test starts, the IFP promas follows: INTERFERING TEST PRESS SEL TO EXE. The test will start once you press SEresponse to the prompt.

During diagnostic tests, the following restrictions apply:

• The IFP is always assumed to be engaged to the source unit in any end-to-end test. Furththe source unit cannot be a remote unit. Therefore, the IFP can only perform an end-to-ewhen it is both Engaged and Attached to a master unit.

• End-to-end tests across the Front Panel (FP) jack are not allowed since this is not considcommunication data link.

• During Dataloop, the target unit is placed in loopback not the local unit. The target mustoptioned for receive timing prior to the test.

ENGAGE

ATTACH

CONFIGURATION

MONITOR

DIAGNOSTICS

MAINTENANCE

RESTORAL

DBU-89 DIRECTORY

MODEM

DBU-89SELF-TEST

SELESC

*

*

*

* OPTIONAL SCREEN - SEE

GROUP LEVEL SUB-GROUP LEVEL

DATALOOP

END-TO-END*

NE

XT

PR

EV

SELF-TEST

SELF-TEST

*

*

*

Figure 5-2

058R467-000 DataComm 9600R / 9600R/IFP 5-27Issue 1 Installation and Operation

Page 56: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

the drop

results get and source

• DBU self-test (Analoop self-test for DBU-89) is supported only if a DBU-89 is installed onattached unit. Performing a DBU-89 Self-Test while on Dial-Backup will cause the unit to the line.

• Block size and bit length selection for all tests are fixed length and may not be adjusted(Block Size = 100, Bit Size = 1000).

At the end of the test, test results are displayed on the LCD. Pressing ESC key will clear the and return you to the diagnostics group screen. If the test is an end-to-end self test, both tarsource test results are reported. Press the NEXT or PREV key to toggle between target andtest results.

The diagnostic tests supported by the IFP are as follows:

• Modem self-test

• DBU-89 self-test (only when DBU-89 is installed)

• Dataloop (only when source unit is a master)

• End-to-end self-test (only when source unit is a master)

5-28 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 57: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

f each

Diagnostic Test Execution

During each test mode, the IFP flashes the name of the test in progress. At the conclusion otest, the IFP displays the results of the test or the failure condition that occurred as shown inFigure 5-16.

Figure 5-16 Diagnostic Response Messages

UNT 0000 BIT ERSUNT 0000 BLK ERS

UNT nnnn BIT ERSUNT nnnn BLK ERS

UNT BIT OVR RNGEUNT BLK OVR RNGE

OR

OR

MODEM STCOMMAND FAILED

DBU-89SELF-TEST PASSED

DBU-89SELF-TEST FAILED

A. MODEM SELF-TEST

B. DBU-89 SELF-TEST

SRC 0000 BIT ERSSRC 0000 BLK ERS

SRC nnnn BIT ERSSRC nnnn BLK ERS

SRC BIT OVR RNGESRC BLK OVR RNGE

OR

OR

DATALOOPCOMMAND FAILED

EXPECTED RESPONSE ERROR RESPONSES EXPECTED RESPONSE ERROR RESPONSES

EXPECTED RESPONSE ERROR RESPONSES EXPECTED RESPONSE ERROR RESPONSES

OR

OR

SRC 0000 BIT ERSSRC 0000 BLK ERSTGT 0000 BIT ERSTGT 0000 BLK ERS

SRC nnnn BIT ERSSRC nnnn BLK ERSTGT nnnn BIT ERSTGT nnnn BLK ERS

SRC BIT OVR RNGESRC BLK OVR RNGETGT BIT OVR RNGETGT BLK OVR RNGE

END-TO-END STCOMMAND FAILEDC. DATALOOP TEST

D. END-TO-END SELF-TEST

058R467-000 DataComm 9600R / 9600R/IFP 5-29Issue 1 Installation and Operation

Page 58: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

isplay ed and of the sword display

Maintenance

The Maintenance group provides the capability to display or perform various maintenance functions on the unit to which the IFP is attached. This group has two modes of operation; dmode, and modify mode. Display mode is automatically selected when a password is requirnot entered. In this mode, the user can display, but not modify the maintenance informationunit to which the IFP is currently attached. Modify mode is automatically selected when a pasis not required, or when a password is required and correctly entered. In this mode, you can and/or perform maintenance functions on the unit to which the IFP is currently attached.

The Maintenance group is entered in the sequence shown in Figure 5-17.

Figure 5-17 Maintenance Sequence

The Maintenance group is divided into the following sub-groups:

• WHAT ARE YOU

• FRONT PANEL CONTROL

• SOFTWARE RESET

• ERASE CONFIGURATION

• ASSIGN ADDRESS

• ACE CALIBRATION

ENGAGE

ATTACH

CONFIGURATION

MONITOR

DIAGNOSTICS

MAINTENANCE

RESTORAL

DBU-89 DIRECTORY FRONT PANELCONTROL

SELESC

*

*

*

* OPTIONAL SCREEN - SEE

GROUP LEVEL SUB-GROUP LEVEL

SOFTWARE RESET

ERASE*

NE

XT

PR

EV

CONFIGURATION

*

*

WHAT ARE YOU

*

*ASSIGNADDRESS

ACE CALIBRATION

Figure 5-2

5-30 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 59: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

a duct ave T

u to ETE

rform n. The

s many dem

ou to n of a

remote

What Are You?

When selected, the WHAT ARE YOU command causes the addressed unit to respond withmessage identifying the type and revision level of the device at that system address, the procode, and the firmware revision level. Once the command is issued, by pressing SEL, you haccess to the information shown in Table 5-15, one screen at a time, by pressing the PREV or NEXkeys.

Front Panel Control

If you press the SEL button in response to FRONT PANEL CONTROL, the IFP will query yoenable or inhibit the front panel test switch. When you press SEL, the unit responds COMPLand the function that was last displayed is initiated. Table 5-16 shows these choices.

Software Reset

The Software Reset subgroup is available during the modify mode only. It enables you to pea soft reset on the attached unit. This routine places the modem in a temporary reset conditiosoftware reset may be used to clear failure conditions on the unit. The reset, however, placefunctions of the unit in an OFF state; dial backup connections are disconnected, and the motransfer units switch operations to the primary modem at a given drop.

When you press SEL in response to the SOFTWARE RESET prompt, the IFP will prompt yPRESS SEL TO EXECUTE. This extra input is designed to help prevent accidental executiosoftware reset. You can press ESC to back out of this function.

Note that resetting the Host unit causes the Host to reset the IFP. This does not occur on a unit since only the Host can reset the IFP. If the unit has been reset, it must be re-engaged.

Table 5-15 Responses To What Are You Command (factory default in bold )

Accessed Information Valid Display

UNIT TYPE 9600R, UNKNOWN

DIAL BACK-UP NONE, DBU-89 INSTALLED

DIAG CHAN SOURCE DAISY CHAN

VF LOOPBACK NORMAL , INHIBIT

FIRMWARE LEVEL Example: A

CTS EXT SUPPORT YES, NO

LINE ADDRESS Example: 001

DROP ADDRESS Example: 04

SERIAL NUMBER Example: 0040091120901015 I

Table 5-16 Front Panel Control Choices

Front Panel Control Choices

FP CONTROL ENABLE, INHIBIT

CAUTION The software reset should only be used when absolutely necessary.

058R467-000 DataComm 9600R / 9600R/IFP 5-31Issue 1 Installation and Operation

Page 60: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

tine nge, or

. The . After

of a

unit

ote unit ngaged.

sign a nit to

u press r of the

ottom

p

is

ACE dress line

current

pon e

Erase Configuration

The Erase Configuration subgroup erases the configuration stored in the Data Set. This roushould be used only as a last resort when the Data Set does not accept a configuration chadoes not operate according to its configuration.

Once you erase the configuration in the Data Set, it reverts to a factory default configurationData Set may or may not operate properly, depending on the requirements of its applicationerasing configurations, the Data Set must be re-engaged and given an address.

When you press SEL in response to ERASE CONFIGURATION, the IFP will prompt you to PRESS SEL TO EXECUTE. This extra input is designed to help prevent accidental erasureData Set's configuration. You can press ESC to back out of this function.

If you press SEL to initiate the erase function, the configuration is erased from the attachedresulting in a default configuration.

Note that the erase function causes the Host to reset the IFP. This does not occur on a remsince only the Host can reset the IFP. If the erase function is performed, the unit must be re-e

Assign Address

The Assign Address subgroup is available during modify mode only. It enables you to re-asunit's address (line, drop) when given the proper serial number. This allows a replacement ube configured with the same address as a malfunctioning unit, prior to replacement. When yoSEL in response to the assign address prompt, the IFP will ask you to input the serial numbeunit that will be given a new address. You input the serial number and then press SEL.

The IFP will then prompt you to input the new line address. Input the line address, move the bcursor to END, and press SEL.

The IFP will, one more time, ask you to enter the new drop address. After you enter the droaddress, press SEL.

If ASSIGN is successful, the IFP displays, ASSIGNED TO LINE XXX DROP XX. If ASSIGNunsuccessful, the IFP displays, ASSIGN FAILED ESC=ABT SEL=RTRY.

The Assign Address process is illustrated in Table 5-17.

ACE Calibration (Automatic Calibration Equalizer)

The ACE Calibration subgroup is available during the modify mode only. The IFP treats the calibration function as any other point-to-point test by requiring the user to enter the target adand using the engaged unit as the source address. ACE calibration will attempt to adjust theequalization on both the target and source modems to obtain optimal performance given the line conditions. Once the function is started, it will execute automatically until successful completion which can take up to three minutes, or until a failure condition is encountered. Usuccessful completion of ACE Calibration, both modems have been equalized for current linconditions.

Table 5-17 Assign Address Process

IFP Prompt User Input

SERIAL NUMBER PROMPT INPUT SERIAL NUMBER OF NEW UNIT

NEW LINE INPUT NEW LINE ADDRESS

NEW DROP INPUT NEW DROP ADDRESS

5-32 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 61: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

enter D, and .

mit

ons.

When you press SEL in response to the ACE Calibration subgroup, the IFP will prompt you tothe target address. Enter the appropriate target address, position the cursor at the word ENpress SEL. The IFP will now display the prompt INTERFERING TEST PRESS SEL TO EXEPress SEL to begin the ACE Calibration function.

When performing an ACE Calibration on a multi-point network, make sure RTS is off on all modems.

Should the ACE Calibration fail, verify that the RX levels are not too hot and adjust the translevels accordingly.

Restoral

The Restoral group provides the capability to control functions used to restore communicati

When SEL is pressed in response to the RESTORAL prompt, you may toggle between the subgroups shown in Figure 5-18 using the PREV and NEXT keys.

Figure 5-18 Restoral Sequence

ENGAGE

ATTACH

CONFIGURATION

MONITOR

DIAGNOSTICS

MAINTENANCE

RESTORAL

DBU-89 DIRECTORY

MODEMFALLBACK

SELESC

*

*

*

* OPTIONAL SCREEN - SEE

GROUP LEVEL SUB-GROUP LEVEL

DBU-89

*

NE

XT

PR

EV

CONTROL

*MODEM

*

*

DBU-89DIAL CELLDBU-89

CONTROL

TERMINATE CALLDBU-89CALL PROGRESSDBU-89PASSWORD

*

*

Figure 5-2

058R467-000 DataComm 9600R / 9600R/IFP 5-33Issue 1 Installation and Operation

Page 62: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

ou

hown

data e data

dial e u or

cell.

r. You

Modem Control

Pressing SEL in response to MODEM CONTROL allows you to modify the MODEM control. Ycan toggle between ENABLE and INHIBIT by pressing the PREV or NEXT key. Inhibiting MODEM CONTROL allows the selected Modem to be taken out of service. The options are sin Table 5-18.

Modem Fallback

Pressing SEL in response to MODEM FALLBACK allows you to modify the fallback control.Modification of the fallback rate does not change the sync, async status associated with therate. For example, if the data rate selection is async, then the fallback rate will by async; if thrate selection is sync, then the fallback rate will be sync. Table 5-19 lists the choices.

DBU-89 Control

The DBU-89 control subgroup allows you to option the unit so that it automatically provides back-up in case of primary link failure. Once the dial backup is initiated because of lease linfailure, it will remain engaged until the operator manually drops the call through the IFP menby momentary disruption of the switch network connection.

The DBU-89 choices are shown in Table Table 5-20.

DBU-89 Dial Cell

The DBU-89 Dial Cell subgroup allows you to select a cell and then dial the contents of that

When the Dial Cell subgroup has been entered, the IFP will prompt you to input a cell numbecan scroll through the cell numbers from 0 to 9 (default is 0) using the PREV or NEXT keys. PressSEL to dial the displayed cell number.

Table 5-18 Restoral Control Choices (factory default in bold )

Restoral Control Restoral Control Choices

MODEM CONTROL ENABLE or INHIBIT

Table 5-19 Fallback Control Choice (factory default in bold )

Fallback Control Choices

MODEM CONTROL ENABLE or INHIBIT

MODEM FALLBACK INHIBIT, 4800, *7200

*When unit is in switched carrier, 7200 is not a valid choice.

Table 5-20 DBU-89 Control Choices (factory default in bold )

Dbu-89 Control Choices

AUTO DBU INHIBIT, ANSWER , ORIGINATE

ACTIVATE DBU ON DCD LOSS, POOR SQM 1 MIN, POOR SQM 5 MIN, POOR SQM 10 MIN, POOR SQM 15 MIN

Note Refer to DBU-89 Directory Group for details on storing telephone numbers into cells.

5-34 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 63: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

e call ring").

he next

e in is

are

lacing shake, atches ery

blank outine ore

Once the command to dial a particular cell number is issued, the IFP automatically enters thprogress monitoring mode (refer to the subsequent paragraph entitled "Call Progress Monito

DBU-89 Terminate Call

The Terminate Call subgroup allows termination of a DBU link.

To select this function, press select in response to the TERMINATE CALL prompt. The IFP executes the command and automatically enters the call progress monitor mode defined in tparagraph.

DBU-89 Call Progress Monitoring

The DBU-89 call progress sub-group monitors call progress conditions of the DBU-89. Whilthis subgroup, the IFP continuously requests call progress information from the DBU-89. Thinformation is displayed on the LCD screen.

The top row of the LCD displays the current call progress state; the bottom row displays supplemental information (this information is usually the reason for a prior failure). Followingthe call progress messages.

DBU-89 Top Row, Call Progress State Messages

DBU: IDLEDBU: DIALINGDBU: HANDSHAKING DBU: RETRAININGDBU: CONNECTED

DBU-89 Bottom Row, Supplemental Prior Failure Messages

HANDSHAKE FAILEDPASSWORD FAILEDREDIAL/LINK EXPBUSYNO DIALTONE

DBU-89 Password

The DBU-89 Dial Backup Unit has password protection to prevent unauthorized users from pa link on dial back-up. Each DBU-89 has one password that may be configured. During handthe originate DBU sends its password to the answer DBU. If the originate unit's password mthe answer unit's password, the call is established, if not, the call is dropped. Note that it is vimportant that all passwords in the network match correctly since the DBU-89 can link to 10different numbers.

To set the password, press SEL in response to DBU-89 PASSWORD. The IFP will display afield on the top row, and a string of numbers on the bottom row. Refer to the Change Mode rpreviously described (see Figure 5-9) to enter the password. When the password is entered (no mthan 8 characters), move the cursor to END and press SEL.

If the password is valid, the IFP will respond with:

DBU PASSWORD(Password)

058R467-000 DataComm 9600R / 9600R/IFP 5-35Issue 1 Installation and Operation

Page 64: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Operating Routines

ll save

s.

ctory rd.

allow

The message will remain on the screen until you press the ESC key, at which time the IFP withe password to the DBU and revert to the DBU-89 PASSWORD option level.

DBU-89 Directory

The DBU-89 directory provides the capability to display or enter DBU-89 telephone numberFigure 5-19 illustrates the sequence used to access the DBU-89 Directory.

Figure 5-19 DBU-89 Directory Sequence

The DBU-89 has ten storage cells each of which can contain up to 36 digits. The DBU-89 Diregroup is only provided when a DBU-89 Card is installed on the DataComm 9600R Base Ca

Press SEL to enter the DBU-89 DIRECTORY and use the PREV or NEXT key to display thedesired cell. To view the contents of the cell, press SEL again. Pressing SEL a third time will you to modify the phone number.

ENGAGE

ATTACH

CONFIGURATION

MONITOR

DIAGNOSTICS

MAINTENANCE

RESTORAL

DBU-89 DIRECTORY

DBU-89CELL 1

SELESC

*

*

*

* OPTIONAL SCREEN - SEE

GROUP LEVEL SUB-GROUP LEVEL

DBU-89

NE

XT

PR

EV

*

*

DBU-89CELL 0

CELL 2

DBU-89CELL 9*

*

.

.

.

.

Figure 5-2

5-36 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 65: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Interim Messages

. These

Interim MessagesThe IFP indicates a transpiring process by flashing a message while the process is occurringmessages are interim until the process is complete. The interim messages are defined in Table 5-21.

Table 5-21 Interim Messages

Interim Message Definition

LOADING OPTIONS Loading options from the current unit

LOADING STATUS Loading status from the current unit

LOADING ALARMS Loading alarms from the current unit

VERIFYING PASSWORD Verifying the entered password

PASSWORD ACCEPTED The correct password has been entered

PASSWORD REJECTED An incorrect password has been entered

ENGAGING Attempting to engage to the specified unit

ATTACHING Attempting to attach to the specified unit

ASSIGNING Attempting to assign a new address

MODEM SELF-TEST The IFP is performing this test

DBU-89 SELF-TEST The IFP is performing this test

DATALOOP TEST The IFP is performing this test

END-TO-END SELF-TEST The IFP is performing this test

SAVING CHANGES Saving changes to the current unit

SOLICITING <unit> Establishing communication for the copy process

READING <option> Reading the option profile from the source unit

WRITING <option> Writing the option profile to the target unit

ESTABLISHING ORIGINAL LINK Restore link prior to copy execution

ACE CALIBRATION The IFP is performing an ACE calibration

ABORTING ACE CALIBRATION The IFP is aborting its current ACE calibration

RESETTING TEST TO NORMAL The IFP is clearing out of its current diagnostic test

OPERATING MODE TEMPLATE The IFP is loading an operating mode template into the current unit

GLOBAL ALARM MASK CONTROL The IFP is modifying the Alarm Masks in the current unit

SAVING OPTIONS Saving options to the current unit

058R467-000 DataComm 9600R / 9600R/IFP 5-37Issue 1 Installation and Operation

Page 66: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Error Messages

r other defined

Error MessagesIf a wrong key is inadvertently pressed, an incorrect response is made to a system prompt, otypes of errors occur, an error message displays on the IFP screen. The error messages arein Table 5-22.

Table 5-22 Error Messages

Error Message Definition

ENGAGE FAlLED No response or incorrect response when attempting to engage

FP CABLE NOT INSTALLED Front Panel cable not installed

DIAG SRC ERROR Diagnostic source error during Engage

UNLIKE UNIT TYPE Unit is not 9600 or 9600R

ATTACH FAlLED No response or incorrect response when attempting to attach

RANGE 1.....127 Parameter must be in range specified

<OPTION> FAlLED Attempt to <option> the unit failed

DBU FAILURE Communication link with DBU failed

CLEAR ALARMS FAlLED Unit failed to accept clear alarms command

FATAL ERROR Encountered an error during diagnostic test

ENABLE FAlLED Command failed to enable

INHIBIT FAlLED Command failed to inhibit

SOFTWARE RESET FAlLED Command failed to cause reset

ERASE FAILED Command failed to erase configuration

ASSIGN FAlLED Unable to assign address

TERMINATE CALL FAlLED Command failed to terminate call

INVALID RESPONSE Incorrect checksum, parity or number of bytes received

END-TO-END ST COMMAND Unit did not enter test FAlLED

MODEM ST FAlLED Unit did not enter test

DBU-89 ST FAlLED Unit did not enter test

DATALOOP TEST COMMAND FAlLED Unit did not enter test

INV SRC RESPONSE Unit encountered communication conflicts with the Source unit

INV TGT RESPONSE Unit encountered communication conflicts with the Target unit

ACE CALBR FAlLED Command failed to complete a successful ACE calibration

5-38 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 67: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Setup and Installation Using the IFP

ulti-p the

roll to

ode are

ssign

e eset

are

ssign

Setup and Installation Using the IFP

The following notes will guide you in setting up the DC9600R or DC9600R/IFP in either a Mpoint synchronous or Multi-point asynchronous network. Set up the remotes before setting umaster.

Multi-point Synchronous Set-up

Remote DC9600R or 9600R/IFP

1. Gain access to the remote unit. (Be sure to say YES to FRC Fake Master.) Refer to Gaining Access To A Unit on page 5-8 for details.

2. Scroll through the menu to the Maintenance Option. Select the Maintenance Option. Scthrough the options to the Erase Configuration option and select it. Configuration returnsfactory default and Master unit returns to the Product Level.

3. Once again, gain access to the remote unit. (Be sure to say YES to FRC Fake master.)

4. Scroll through the Group Level and choose the Configuration menu. Select Operating MTemplate. Choose 9600S MLT-PT-RMT. Change modem options as required. If changesmade, be sure to same them at the prompt.

5. Return to the Group Level and select the Maintenance Option. Select Assign Address. Athe Line and Drop Address.

Master DC9600R or DC9600R/IFP

1. Engage the host unit. (Be sure to select NO on FRC Fake Master menu option.)Unit will engage and display its address.

2. Scroll through the Group Level menu to the Maintenance Option. Select the MaintenancOption. Scroll through the options to the Erase Configuration and select it. The unit will rto the factory default configuration and return to the Product Level screen.

3. Engage the host unit again. (Be sure to select NO on FRC Fake Master menu option.)Unit will engage and display its address.

4. Return to the Group Level and choose the Configuration menu. Select Operating Mode Template. Choose 9600S MLT-PT-MST. Change modem options as required. If changesmade, be sure to save them at the prompt.

5. Return to the Group Level and select the Maintenance Option. Select Assign Address. Athe Line and Drop Address. (Refer to Assign Address on page 5-32 for details.)

DataComm9600R/IFP

DataComm9600R or IFP

DataComm9600R or IFP

Master

Remote 1 Remote N Remote 2

058R467-000 DataComm 9600R / 9600R/IFP 5-39Issue 1 Installation and Operation

Page 68: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Setup and Installation Using the IFP

at the

t the

hen ere

roll to

ode are

ssign

e eset

are

ssign

at the

t the

You are now ready to perform the ACE Calibration. Be sure all remotes are configured and Product Level screen prior to continuing with these steps:

6. Return to the Product Level screen once again. Engage the host unit and select YES aFRC Fake Master option.

7. To perform the ACE Calibration, select the Maintenance option from the Group Level. Tselect ACE Calibration option and enter the address for any configured remote unit. (If thare no DC9600R or DC9600R/IFP remotes, do not perform the ACE Calibration.)

8. Repeat step 5 for each remote unit.

Multi-point Asynchronous Set-up

Remote DC9600R or 9600R/IFP

1. Gain access to the remote unit. (Be sure to say YES to FRC Fake Master.) Refer to Gaining Access To A Unit on page 5-8 for details.

2. Scroll through the menu to the Maintenance Option. Select the Maintenance Option. Scthrough the options to the Erase Configuration option and select it. Configuration returnsfactory default and Master unit returns to the Product Level.

3. Once again, gain access to the remote unit. (Be sure to say YES to FRC Fake master.)

4. Scroll through the Group Level and choose the Configuration menu. Select Operating MTemplate. Choose 9600A MLT-PT-RMT. Change modem options as required. If changesmade, be sure to same them at the prompt.

5. Return to the Group Level and select the Maintenance Option. Select Assign Address. Athe Line and Drop Address.

Master DC9600R or DC9600R/IFP

1. Engage the host unit. (Be sure to select NO on FRC Fake Master menu option.)Unit will engage and display its address.

2. Scroll through the Group Level menu to the Maintenance Option. Select the MaintenancOption. Scroll through the options to the Erase Configuration and select it. The unit will rto the factory default configuration and return to the Product Level screen.

3. Engage the host unit again. (Be sure to select NO on FRC Fake Master menu option.)Unit will engage and display its address.

4. Return to the Group Level and choose the Configuration menu. Select Operating Mode Template. Choose 9600A MLT-PT-MST. Change modem options as required. If changesmade, be sure to save them at the prompt.

5. Return to the Group Level and select the Maintenance Option. Select Assign Address. Athe Line and Drop Address. (Refer to Assign Address on page 5-32 for details.)

You are now ready to perform the ACE Calibration. Be sure all remotes are configured and Product Level screen prior to continuing with these steps:

6. Return to the Product Level screen once again. Engage the host unit and select YES aFRC Fake Master option.

5-40 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 69: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Tests

hen ere

e IFP ing the

7. To perform the ACE Calibration, select the Maintenance option from the Group Level. Tselect ACE Calibration option and enter the address for any configured remote unit. (If thare no DC9600R or DC9600R/IFP remotes, do not perform the ACE Calibration.)

8. Repeat step 5 for each remote unit.

TestsThe DataComm 9600R Data Set with the Intelligent Front Panel (IFP) may be tested using thdiagnostics routing (discussed earlier in this chapter). In addition, tests may be performed usNorm/Test switch on the IFP (see Chapters 2 and 3 of this manual).

058R467-000 DataComm 9600R / 9600R/IFP 5-41Issue 1 Installation and Operation

Page 70: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Intelligent Front Panel Tests

5-42 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 71: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Appendix A: Technical Characteristics

Table A-1 Technical Characteristics for DC9600R

Item Specification

Physical PC card

Height (9600R with IFP or DBU) 1.75 in (45 mm)

Height (9600R Only) 0.75 in. (20 mm)

Width 18 oz. (0.51 kg)

Depth 10.75 in. (273 mm)

Weight (9600R Only) 18 oz. (0.51 kg)

Standalone installation

Height 3.9 in. (99 mm)

Width 10.9 in. (277 mm)

Depth 12.5 in. (318 mm)

Weight (Standalone Enclosure) 5 lb., 12 oz (2.61 kg)

Environmental Temperature, pc card assembly

Operating 32o to 122oF (0o to 50oC)(Derate by 1oC/1000 ft above sea level)

Nonoperating -40o to 185oF (-40o to 85oC)

Temperature, standalone

Operating 32o to 122oF (0o to 50oC)

Nonoperating -40o to 158oF (-40o to 70oC)

Humidity, operating 0% to 95% without condensation

Altitude

Operating 0 ft to 10,000 ft (0 m to 3.047 m)

Non-operating 0 ft to 40,000 ft (0 m to 12,191 m)

Electrical Power requirements

(Standalone or Rackmount) 100-129 V ac 60 Hz

Power Dissipation

Standalone 15 W maximum

Rackmount 10 W maximum

Fusing

Enclosures Refer to respective enclosure manuals for fusing requirements.

PC card Two 1.5 A, 250 V, 3AG (GDC Part No. 215-300-150)

058R467-000 DataComm 9600R / 9600R/IFP A-1Issue 1 Installation and Operation

Page 72: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Technical Characteristics

Electrical (cont.) Data Format Synchronous, Asynchronous, Serial Binary

Operating Mode 4-wire Private Line, full duplex, point-to-point or multipoint

Line Requirement 3002 unconditioned or better

Line Impedance 600 ohms balanced

Business Machine interface EIA-232-D; CCITT V.24/V.28

Primary Channel Data Rate:

Normal 9600 bps

Fallback 7200 bps or 4800 bps, (V.29 point-to-point only)

Transmitter:

Modulation QAM

Carrier Frequency 1700 Hz ± 1.0 Hz, all modes except super poll, which is 1800 ± 1.0 Hz,

Output Level Adjustable 0 to 15 dBm, in 1 dB steps

Line Equalization Compromised adjustable

Timing Source 9600 Hz (± .01 %.) internal, external, or receiver

RTS/CTS Delay:

Constant Carrier Constant carrier with CTS always on CTS controlled by RTS with either 0 to 1.5 ms, 8 ± 2.o ms or 15 ± 2.0 ms

Switched Carrier RTS/CTS delays are 19 ±.0 ms or 10 ± 2.0 ms

Receiver

Demodulation Differential coherent detection of QAM

Carrier Detect:

Carrier Threshold -26 dBm ON, -31 dBm OFF

Carrier Detect Acquisition Following synchronization

Hysteresis Min. 2 dB

Carrier Detect Release 20 ms ± 9 ms (V.29) or 6 ms ± 5 ms

Balance Longitudinal balance is minimum of 50 dB between 350-3000 Hz

Secondary Channel:

Data Rate 75 bps asynchronous

Modulation FSK, Mark 305 Hz, Space 355 Hz

Output Level 10 ± 2.0 dB below Primary Channel

Carrier Detect Threshold -41 dBm ON, -46 dBm OFF

Carrier Detect Release 2dB minimum

Table A-1 Technical Characteristics for DC9600R (Continued)

Item Specification

A-2 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 73: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Technical Characteristics

IFP Only CPU:

Processor Intel 8031

Type 8-bit

Clock Speed 7.992 MHz

Memory:

ROM 27C512

Table A-1 Technical Characteristics for DC9600R (Continued)

Item Specification

058R467-000 DataComm 9600R / 9600R/IFP A-3Issue 1 Installation and Operation

Page 74: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Technical Characteristics

A-4 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 75: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Appendix B: Equipment List

Table B-1 Equipment for DataComm 9600R

Description Part No.

DataComm 9600R Modem, Standalone 058A080-005

DataComm 9600R Modem, Rackmount 058P118-005

DataComm 9600R Modem with DBU-89, Standalone 058A080-025

DataComm 9600R Modem with DBU-89, Rackmount 058M119-025

DataComm 9600R Modem with IFP, Standalone (S/A) 058A080-015

DataComm 9600R Modem with IFP and DBU-89 Dial Backup Card (S/A) 058A080-035

DataComm 9600R Modem with IFP, Rackmount (R/M) 058P118-015

DataComm 9600R Modem with IFP, and DBU-89 (R/M) 058M119-035

DataComm Standalone Enclosure

Base Assembly, 117 V ac (DE-19) 010B117-001

Cover, Single 010D500-003

Cover, Double 010D500-004

Cover, Double with DBU-89 010D554-001

DataComm Shelf Assemblies

D-1, 117Vac 010B015-001

DS-5, 48 V dc Redundant power supplyNonredundant power supply

010M011-001010M011-002

DS-6, 48 V dcRedundant power supplyNonredundant power supply

010M047-001010M047-002

Universal System Shelf Assemblies

USS-1-D, 117 V ac 010B080-001

USS-1-DC/NR 010M040-001

USS-1-DC/R 010M040-002

Optional Assemblies

Jack-to-Jack Cable, 9600R/IFP 830-062-001

Cable Assembly, Private Line, Modular, 8PLG/8PLG, S/T(last 2 digits of part number indicate feet in length)

830-028-807830-028-814830-028-825830-028-850

Cable, Private Line, VF 4-wire(Last 3 digits of part number indicate feet in length)

023H101-010023H101-020023H101-250

058R467-000 DataComm 9600R / 9600R/IFP B-1Issue 1 Installation and Operation

Page 76: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Equipment List

B-2 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 77: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Appendix C: Business EquipmentInterface Signals

Pin No.*

Circuit Designation

Signal Description CCITT EIA

9600R Modem

1 101 AA GND Protective ground This circuit is connected to the equipment frame. Normally, it is separated from signal ground, pin 7, by 100 ohms of resistance, but using jumper plug X3 connects it directly to signal ground.

2 103 BA TD Transmitted data Transfers data signals from DTE to Modem for modulation and transmission over communications line.

3 104 BB RD Received data Transfers data signals to DTE that were received over communications line and demodulated by Modem.

4 105 CA RTS Request-to-send Indicates to modem that DTE is prepared to transmit.

5 106 CB CTS Clear-to-send Indicates to DTE that Data Set is prepared to transmit.

6 107 CC DSR Data set ready Indicates to DTE that modem is prepared for data communications.

7 102 AB SIG GND Signal ground Establishes common ground reference for all interface circuits except protective ground, pin 1.

8 109 CF DCD Received line signal detector

Indicates to DTE that modem is receiving a signal at a level greater than the carrier detect threshold.

9 - - +12V + 12 volts + 12 v supply

10 - - -12V -12 volts -12 v supply

15 114 DB TXC Transmitter signal element timing

Transfers transmitter signal timing information from Modem to DTE.

17 115 DD RXC Receiver signal element timing (DCE)

Transfers receiver signal timing information from modem to business equipment (data terminal).

20 108.2 CD DTR Data terminal ready Indicates to Modem that DTE is prepared for data communications.

24 DA 113 ETXC Transmitter signal element timing (DTE source)

Transfers transmitter signal timing information from DTE to Modem.

25 142 - TM Test mode Indicates to DTE that Data Set is in a test mode.

* Pins 11, 12, 13, 14, 16, 18, 19, 22, and 23 are not used.

058R467-000 DataComm 9600R / 9600R/IFP C-1Issue 1 Installation and Operation

Page 78: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Business Equipment Interface Signals

C-2 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 79: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Appendix D: Pin Designations

Table D-1 Private Line Modular Jack Pin Designations

Pin NumberPrivate Line

4-wire

1 TX-A

2 TX-B

3 no connection

4 no connection

5 no connection

6 no connection

7 RX-B

8 RX-A

Table D-2 Private Line Terminal Block Pin Designations

TerminalBlock

Private Line4-wire

TB1-1 TX-B

TB1-2 TX-A

TB1-3 RX-B

TB1-4 RX-A

Table D-3 DBU-89 Card (058P119-001) Pin Designations

Modular Connector J1 Pin

No. Function

DBU-89 Card

Connector P2 Connector P3

5 Tip 18 7

4 Ring 20 8

7 Programmable Resistor (PR) 16 18

8 Programmable Common (PC) 1 9

058R467-000 DataComm 9600R / 9600R/IFP D-3Issue 1 Installation and Operation

Page 80: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description

Pin Designations

D-4 DataComm 9600R / 9600R/IFP 058R467-000Installation and Operation Issue 1

Page 81: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description
Page 82: DataComm 9600R / 9600R/IFP Installation and Operation · 2000. 5. 23. · 058R467-000 DataComm 9600R / 9600R/IFP 1-1 Issue 1 Installation and Operation Chapter 1: Introduction Description