Upload
teresa-cooper
View
246
Download
7
Tags:
Embed Size (px)
Citation preview
3
The off-line programming tool provides legacy database converter feature that can convert system data of NCP/TDE/TDA series PBX into data for NS1000.
TDE/NCP
NS1000
DGSYS DCSYSConvert Edit
TDA
DBSYS
DMSYS
DLSYS
DSYS
The data of TDA should convert it into the data of TDE in UPCMC. Then it can be used for conversion into the data of NS1000.
Database Converter (NS1000 Off line mode V2.0)
Over view 1/3
Activation key is not transferred at the converting database
Off line tool (V2.0)UPCMC (PBX Replacement)
report
NS1000 is overwritten in new DCSYS.
TDA100 /200
TDA600
TDE100 /200
TDE600
NCP500 /1000
4
The feature supports 2 functionalities as follows.
1) Platform Replacement (TDE/NCP->NS1000) Legacy database converter for replacing to NS1000 from legacy PBX The target data of convert is the data of only IP Trunk and IP terminal.
IP TrunkV-IPGW16,V-SIPGW16
IP TrunkV-IPGW16,V-SIPGW16IP-GW4,16 It’s not supported.
The data of a physical IP-GW card is not converted.
IP terminalV-IPEXT32V-SIPEXT32V-IPCS4 IP-EXT16 (Physical card)
IP terminalV-IPEXT32V-SIPEXT32V-IPCS4
TDA/TDE/NCPNS1000
Database Converter (NS1000 Off line mode V2.0)
Over view 2/3
TDA/TDE/NCP
not used
5
Legacy Trunk Legacy Trunk
DPT/SLT DPT/SLT
STACK-M
STACK-STDA/TDE/NCP
2) Platform As Legacy GW Data (TDE/NCP->NS1000+Legacy GW) Legacy database converter for using existing PBX as legacy gateway.
IP TrunkV-IPGW16,V-SIPGW16IP-GW4,16 It’s not supported.
IP terminalV-IPEXT32V-SIPEXT32V-IPCS4 IP-EXT16 (Physical card)
IP TrunkV-IPGW16,V-SIPGW16
IP terminalV-IPEXT32V-SIPEXT32V-IPCS4
Of course, data related to IP is converted like case “1) Platform Replacement”.
Database Converter (NS1000 Off line mode V2.0)
Over view 3/3
PS can be used without re-registration.
7
The database converter is a part of application in off-line programming software and it is initiated by clicking the icon on launcher of the off-line programming. Note: Not support to convert via Web-MC (On-line)
The following table shows target series of PBX and the version number to be converted.
Series of PBX Version number Remark
NCP500/1000 Ver. 6
TDA100/200 Ver. 5 *1
TDE100/200 Ver. 6
TDA600/620 Ver. 5 *1
TDE600/620 Ver. 6
*1: Database file has to be converted into DGSYS or DMSYS of KX-TDE by using data replacement application on PCMC before the legacy database convertor.
Condition 1/7
Database Converter (NS1000 Off line mode V2.0)
8
Condition 2/7
Database Converter (NS1000 Off line mode V2.0)
Originated PBX
Programming items
Extension *1,*2Trunk*3,*4
Numbering Plan
COSDDI/DID
Group SSD PSD CTI
NCP500/1000TDE100/200/600
IP ExtensionPS/IP-CS IP Trunk Yes Yes Yes Yes Yes Yes Yes
TDA100/200/600IP Ext. of IP-EXT
card - Yes Yes Yes Yes Yes Yes Yes
Mode: Platform Replacement (TDE/NCP->NS1000)
The following table shows which programming items can be converted
*1: Include Extension number, Extension name, FF key data*2: Only support IP Extension and PS/IP-PS*3: Include Trunk number *4: IP trunk of IP-GW card is not supported.
9
Condition 3/7
Database Converter (NS1000 Off line mode V2.0)
Originated PBX Convert to
Programming Items
Extension *1
Trunk *2
Numbering Plan
COSDDI/DID
Group SSD PSD CTI
NCP500/1000TDE100/200TDA100/200
Legacy GW1
All Ext.All
TrunkYes Yes Yes Yes Yes Yes Yes
TDE600/TDA600(Basic shelf)
Legacy GW1
All Ext.. All
Trunk Yes Yes Yes Yes Yes Yes Yes
TDE600/620TDA600/620(Basic shelf & Expansion shelf 1)
Legacy GW1+GW2+GW3+GW4
All Ext.All
Trunk Yes Yes Yes Yes Yes Yes Yes
Mode: Platform As Legacy GW Data (TDE/NCP->NS1000+Legacy GW)
*1: Include Extension number, Extension name, FF key data*2: Include Trunk number
10
Available converting patterns
pattern 1 (Replacement :Only IP)
TDA/TDE/NCP NS1000
TDA/TDE/NCP NS1000
pattern 2 (Included Legacy)
TDA/TDE/NCP
pattern 3
NS1000
TDE620TDE600
Shelf 1
Shelf 2 Legacy GW1
Legacy GW2
Shelf 1 Shelf 2
Converting database of TDE/TDA multi cabinet to legacy gateway units.
Legacy GW1
Please connect existing PBX with Legacy GW1.
Database Converter (NS1000 Off line mode V2.0)
Condition 4/7
TDE600TDE620
TDE600TDE620
11
Available converting patterns
pattern 4
NS1000
Shelf 1
Shelf 2
TDA620TDA620
TDE620TDE600
NS1000
Shelf 3
Shelf 4
Shelf 1 Shelf 2 Shelf 3 Shelf 4
Legacy GW1
Legacy GW2
Legacy GW1
Legacy GW2
Master Slave
One Look NetworkingConverting database of TDE/TDA multi cabinet to legacy gateway units on NS1000 slave units.
Database Converter (NS1000 Off line mode V2.0)
Condition 5/7
The shelf location is fixed.
12
TDA/TDE/NCPTDA/TDE/NCP
TDA/TDE/NCP
Unavailable converting patterns
pattern 1
NS1000
Legacy GW2
Master
Legacy GW1
NS1000 NS1000
Legacy GW1
Master SlaveOne Look Networking
Legacy GW1
This tool doesn't support data conversion of the multi system.
TDA/TDE/NCP
TDA/TDE/NCPTDA/TDE/NCP
Multi system
Database Converter (NS1000 Off line mode V2.0)
Condition 6/7
13
Legacy GW1
Legacy GW2
Unavailable converting patterns
pattern 2
NS1000 NS1000
Master Slave
One Look Networking
This tool doesn't support the data conversion connected with the slave.
NS1000
pattern 3
TDA/TDE/NCP
TDA/TDE/NCP
TDA/TDE/NCP
TDA/TDE/NCP
This tool doesn't support the data conversion connected with the Legacy GW2.
Database Converter (NS1000 Off line mode V2.0)
Condition 7/7
14
Table of item not converted 1/3
The converted value is indicated in right column
Function Value (after the converted)
Time Service Switching Mode The default setting
Time Setting ( Time Table) Clear
Timed Reminder Clear
Extension Dial Lock Unlock
Remote Extension Dial Lock Unlock
Call Charge data Clear
Not Ready (Manual Wrap-up) Mode On / Off Off
LCS On/Off Off
Hospitality Features ( Check In/Out Not Ready/Cleaned Up )
Clear
Auto Answer The default setting
Database Converter (NS1000 Off line mode V2.0)
15
Function Value (after the converted)
Absent Message The default setting
Last Number Redial Clear
Changing the Log-in/Log-out Status of Extensions
Clear
Message Waiting Clear
Incoming Call Log Clear
Call Charge Clear
Outgoing Call Log Clear
TAM Log Clear
OGM Clear
Call Forwarding (FWD)/Do Not Disturb (DND) Settings
Off
Traffic data Clear
Database Converter (NS1000 Off line mode V2.0)
Table of item not converted 2/3
16
Function Value (after the converted)
Verification Code PIN Lock state Unlock
Verification Code PIN Lock counter Clear
Password Lock counter for Remote System Programming
Clear
Major/Minor alarms Clear
Error Log Clear
Wake-up Call Clear
Database Converter (NS1000 Off line mode V2.0)
Table of item not converted 3/3
17
Unavailable cards 1/1
Following components can not be used with Legacy-GW.These data is deleted.
Symbol Model Description
RMT TDA0196 Analogue Modem for Remote Maintenance
MEC TDA0105/TDE0105 Memory Expansion Card
DSP4/16/64 NCP1104/TDE0110/TDE0111 VoIP channel card 4ch/16ch/64ch
CTI-LINK TDA0410 CTI Link Card
IP-EXT16 *1 TDA0470 16-Channnel VoIP Extension Card
IP GW4/IP-GW4E TDA0480/TDA0484 4-Channnel VoIP Gateway Card
IP-GW16 TDA0490 16-Channnel VoIP Gateway Card
MSG4 TDA0191 4-Channel Message Card
ESVM2/4 TDA0192/TDA0194 2/4-Channel Simplified Voice Message Card
CLCOT8 * 1 TDA1180 8-Port Analogue Trunk Base Card w/ Caller ID
CLCOT8E * 1 TDA1186 8-Port Analogue Trunk Daughter Card w/ Caller ID
MCSLC24 TDA1178 24-Port Single Line Telephone Card
MCSLC16 TDA1176 16-Port Single Line Telephone Card
Database Converter (NS1000 Off line mode V2.0)
*1: The data of IP extension is taken over to a virtual extension card.
18
- TDA Database (DSYS and DLSYS) file has to be converted into DGSYS or DMSYS of KX-TDE by using data replacement application on PCMC before the legacy database convertor.
-New program items added in NS1000 are filled by the default value.
-All data of numbering plan are switched to originated (New DCSYS) data since the default values are different between NS1000 and other PBXs.
-New setting of dial plan added in NS1000, which is not in legacy PBXs, are filled with BLANK.
-OPB card and any card on OPB card are not supported to convert.
-Activation key is not transferred at the converting database.
Note 1/1
Database Converter (NS1000 Off line mode V2.0)
19
Procedure of conversion 1/7
DGSYS
Convert
DBSYSDMSYS
Converter type needs to be selected from the following 2 types at initiation of converter application.
1) Replacement2) Legacy Gateway
After this selection, some of mandatory system setting need to be programmed, then DCSYS file for NS1000 is created automatically.
Database Converter (NS1000 Off line mode V2.0)
or or
NS1000 Off line V2.0
20
Procedure of conversion 2/7
It depends on data before it converts it then the composition chart is shown.
Database Converter (NS1000 Off line mode V2.0)
For NCP, TDA/E100, and TDA/E200
For TDA/E600, and TDA/E620when the slave is connected
21
A part of region should change the setting. Please refer to P26.
Parametes and operation is completely same as Easy Setup wizard.
IP addresses, type of registration and password, etc programmed on TDE/NCP are displayed by default.
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 3/7
Converting time is estimated to take with in 10 seconds
P23 (Case with TDE100/200/NCP)
P22 (When the slave is connected)
22
This operation is required in case source database file contains an more than 3 expansion unit setting of TDA/E600/620.
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 4/7
Converting time is estimated to take with in 10 seconds
P23
23
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 5/7
When the conversion of data is completed, the report of the result is displayed.
Example Following Recommended A.K Deleted Card
Activation key is not transferred at the converting database
24
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 6/7
Connection Online Mode
Finish
Open Offline mode
DCSYS
The name is given to the new data. ( DCSYS)
And, converted DCSYS is downloaded.
The following three steps can be selected.
25
Database Converter (NS1000 Off line mode V2.0)
Procedure of conversion 7/7
C:\Documents- - - -DCSYS
The reset operation is necessary.
Please transfer (Installation) the “converted DCSYS” on Online mode.
26
Suffix Code 1/1
Suffix code Area
NE CE
BX BX
RU RU
Suffix code Area Note
NE CE Eastern Europe
TR Turkey
BX BX Other
TW Taiwan
RU RU Russia
UC UC Ukraine
Legacy gateway NS1000
Please change the setting to the area shown in the following tables.
In area other than this table, the change is unnecessary.
Database Converter (NS1000 Off line mode V2.0)
27
Result of Converting 1/2
The following results are displayed when data conversion is completed.It might be effective help to make the New Configuration of NS1000. These contents are examples.
Report of conversion result (examples)Complete of Database conversion
Original file : PSN_TDE600
Original PBX : TDE600
Following Recommended A.K.
One-look Networking
Up to 100 IP Phone Capacity
Deleted Card
Shelf1,Slot01 : IP-EXT16
Deleted Extension
6780, 6781, 6782, 6783, 6784, 6785, 6786, 6787,
16788,16789,16790,16791, 792, 793, 794, 795
Shelf1,Slot02 : IP-GW16
Deleted CO line
007,008,009,010,011,012,013,014,
015,016,017,018,019,020,021,022
Shelf1,Slot01-01 : OPB3 - MSG4
Database Converter (NS1000 Off line mode V2.0)
Both the deleted extension number and the deleted CO number are described.
Recommended AK is displayed.
OPB card and any card on OPB card are not supported to convert.
28
Report of conversion result (examples)
Deleted Card
Shelf4,Slot15 : MCSLC16
Deleted Extension
10001,10002,10003,10004,10005,10006,10007,10008,
10009,10010,10011,10012,10013,10014,10015,10016
Deleted Remote Access Device
599 : MODEM
699 : ISDN Remote
Change
IP-EXT16 : Shelf1,Slot01 -> V-IPEXT32 : Site01,Slot47
IP-EXT16 : Shelf2,Slot01 -> V-IPEXT32 : Site01,Slot47
IP-EXT16 : Shelf4,Slot01 -> V-IPEXT32 : Site02,Slot47
Change SVM-Voice Msg Extension No. to UM channel No.
591 : SVM-Voice Msg1 -> 5101 : Master UM channel 1
592 : SVM-Voice Msg2 -> 5102 : Master UM channel 2
New Assigned
5103 : Master FAX Extension number
Database Converter (NS1000 Off line mode V2.0)
Result of Converting 2/2
Two IP-EXT16 cards were integrated into one V-IPEXT32 card.
31
Application model (1/1)
KX-NS1000 allows connecting following system for legacy gateway system.It means “The data of the application model is convertible “.
Legacy Platform's Models Yes/No
TDA 15 No
30/50 No
100/200 Yes
600/620 Yes
100D No
TDE 100/200 Yes
600/620 Yes
NCP 500/1000 Yes
500 express Yes
Database Converter (NS1000 Off line mode V2.0)
Appendix : Supported PBX model
32
Database Converter (NS1000 Off line mode V2.0)
Change of version of DSYS (1/1)
Appendix : Change of version of DSYS from V4 to V6
DGSYS
Example
V4
DGSYS V6
Please use version 6 or late of UPCMC.
33
Suffix code Area
NE G
NE BL
NE DK
NE FI
NE FR
NE JT
NE NL
NE NO
NE PT
NE SP
NE SE
NE SL
NE CE
NE CE
E E
GR GR
AL AL
NZ NZ
Suffix code Area Note
NE G Germany. Austria
NE BL Belgium/Luxembourg
NE DK Denmark
NE FI Finland
NE FR France
NE JT Italy
NE NL Netherlands
NE NO Norway
NE PT Portugal
NE SP Spain
NE SE Sweden
NE SL Switzerland
NE CE Eastern Europe
NE TR Turkey
UK UK UK
NE GR Greece
AL AL Australia
AL NZ New Zealand
Suffix Code and Area table. (1/2)
Appendix : Suffix Table
Database Converter (NS1000 Off line mode V2.0)
Please select the Area on the converter.
34
Suffix code Area Note
XE HK Hong Kong
XE ML Malaysia
XE SN Singapore
BX BX Others
M M USA
BX BX Other
BX TW Taiwan
BX BX BX
BX SA South Africa
AG AG Argentina
C C Canada
NE CE Eastern Europe
RU RU Russia
UC UC Ukraine
BR BR Brazil
Suffix code Area
HK HK
ML ML
SN SN
CN CN
M M
BX BX
BX BX
BX BX
BX SA
AG AG
C C
CE CE
RU RU
RU RU
BR BR
Database Converter (NS1000 Off line mode V2.0)
Suffix Code and Area table. (2/2)
Please select the Area on the converter.
Appendix : Suffix Table