7/29/2019 Data Sheet of Cable
1/2
SUHNER COAXIAL CABLE DATA SHEET
WAIVER!
While the information contained in this folder has been carefully compiled to the best of our present knowledge,
it is not intended as representation or warranty of any kind on our part regarding the fitness of the products
concerned for any particular use or purpose and neither shall any statement contained herein be constructed asa recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of
each product for any particular purpose must be checked beforehand with our specialists.
Issued: 22.9.2004 12:37 Document:
DOC-0000177852.DOC
RF_Co_Ca_PDF
uncontrolled copy Page 1
HUBER+SUHNER AGDivision ISDCH-9100 HerisauPhone +41 (0)71 353 41 11
Fax +41 (0)71 353 45 90http://www.hubersuhner.com
TYPE S_06162_D-02Double screened coaxial cable
Cable Design
Material Detail DiameterCentre conductor: Copper: Silver Plated Wire 2.05 mm
Dielectric: SPE (Foamed Polyethylene) 5.6 mm
1. Outer conductor: Copper: Silver Plated Braid 93% 6.1 mm
2. Outer conductor: Copper: Silver Plated Braid 85% 6.75 mm
Jacket: PE (LSFH) RAL 9005 - bk 7.9 mm +/- 0.1
Print: HUBER+SUHNER S 06162 D-02 50 Ohm (PA no.)
Electrical DataImpedance: 50 +/-2Max. operating frequency: 6 GHz
Capacitance : 81.6 pF / m
Velocity of signal propagation: 82 %Signal delay: 4.08 ns / m
Min. screening effectiveness: > 82 dB(up to 6 GHz)Max. operating voltage: 0.75 kVrms(at sea level)Test voltage: 1.5 kVrms(50 Hz/ 1min)
Insulation resistance: > 1 x 10 6 M/m
General Data
Temperature range: -40C... +85 CWeight: 11 kg / 100 m
Min. bending radius : static 30 mm
repeated (for max. 50 bendings) 60 mm
Suitable ConnectorsCable group S24(for details refer to the SUHNER coaxial connector catalogue or contact your nearest HUBER+SUHNER partner)
Notes
7/29/2019 Data Sheet of Cable
2/2
SUHNER COAXIAL CABLE DATA SHEET
WAIVER!
While the information contained in this folder has been carefully compiled to the best of our present knowledge,
it is not intended as representation or warranty of any kind on our part regarding the fitness of the products
concerned for any particular use or purpose and neither shall any statement contained herein be constructed asa recommendation to infringe any industrial property rights or as a license to use any such rights. The fitness of
each product for any particular purpose must be checked beforehand with our specialists.
Issued: 22.9.2004 12:37 Document:
DOC-0000177852.DOC
RF_Co_Ca_PDF
uncontrolled copy Page 2
HUBER+SUHNER AGDivision ISDCH-9100 HerisauPhone +41 (0)71 353 41 11
Fax +41 (0)71 353 45 90http://www.hubersuhner.com
TYPE S_06162_D-02
Matrix Attenuation[formula : (a*f^0.5 +b*f) ]and Power CW[formula : (p*/ f^0.5) ]Coefficients:a= 0.193 b= 0.0363 fmax=.6 pat 1GHz=180
Frequency Nom. attenuation Nom. attenuation Max. CW power(GHz) (dB / m) (dB / ft) (watt)
sea level
25 C ambient temperaturesea level
25 C ambient temperaturesea level
40 C ambient temperature
0.30 0.117 0.0357 328.6
0.60 0.171 0.0521 232.4
0.90 0.216 0.0658 189.7
1.20 0.255 0.0777 164.3
1.50 0.291 0.0887 147.0
1.80 0.324 0.0988 134.2
2.10 0.356 0.1085 124.2
2.40 0.386 0.1176 116.2
2.70 0.415 0.1265 109.5
3.00 0.443 0.1350 103.9
3.30 0.470 0.1432 99.1
3.60 0.497 0.1515 94.9
3.90 0.523 0.1594 91.1
4.20 0.548 0.1670 87.8
4.50 0.573 0.1746 84.94.80 0.597 0.1820 82.2
5.10 0.621 0.1893 79.7
5.40 0.645 0.1966 77.5
5.70 0.668 0.2036 75.4
6.00 0.691 0.2106 73.5
Test (following tests have been passed successfully)Flame propagation: IEC 60332-1 UL 1581 - 1080 (VW-1)
Halogen content: IEC 60754