6
Data sheet 3KC0432-2NE00-0AA0 SENTRON, transfer switching equipment 3KC, manually operated, MTSE, size: 2, 4-pole, Iu: 125 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 125 A, Ie at AC-23 A at 690 V: 125 A, screw and standard mounting rail on 35 mm, front operating mechanism, central, without handle, box terminal Model Product brand name SENTRON Product designation 3KC transfer switching equipment Design of the product manually operated Type of the driving mechanism / motor drive No Number of poles 4 Type of device fixed mounting Position / of the switch operating mechanism in center Insulation voltage ● rated value 1 000 V Overvoltage in percent / relative to the operating voltage / at AC / at 50/60 Hz 5% Protection class Protection class IP IP20 Protection class IP ● with closed switch / with cover or cable lug cover IP20 ● on the front IP20 Current / at AC / rated value 125 A 3KC0432-2NE00-0AA0 Subject to change without notice Page 1/ 6 05/17/2018 © Copyright Siemens

Data sheet 3KC0432-2NE00-0AA0 · 2018. 6. 1. · Continuous current / rated value 125 A Main circuit Operating power at AC-23 A / at 400 V / at 50/60 Hz / rated value 55 kW at AC-23

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Data sheet 3KC0432-2NE00-0AA0 · 2018. 6. 1. · Continuous current / rated value 125 A Main circuit Operating power at AC-23 A / at 400 V / at 50/60 Hz / rated value 55 kW at AC-23

Data sheet 3KC0432-2NE00-0AA0SENTRON, transfer switching equipment 3KC, manually operated,MTSE, size: 2, 4-pole, Iu: 125 A, Ue AC: 415 V, Ie at AC-33 B at 415V: 125 A, Ie at AC-23 A at 690 V: 125 A, screw and standardmounting rail on 35 mm, front operating mechanism, central, withouthandle, box terminal

ModelProduct brand name SENTRONProduct designation 3KC transfer switching equipmentDesign of the product manually operatedType of the driving mechanism / motor drive NoNumber of poles 4Type of device fixed mountingPosition / of the switch operating mechanism in centerInsulation voltage

● rated value 1 000 V

Overvoltage in percent / relative to the operatingvoltage / at AC / at 50/60 Hz

5 %

Protection classProtection class IP IP20Protection class IP

● with closed switch / with cover or cable lugcover

IP20

● on the front IP20

Current / at AC / rated value 125 A

3KC0432-2NE00-0AA0 Subject to change without noticePage 1/6 05/17/2018 © Copyright Siemens

Page 2: Data sheet 3KC0432-2NE00-0AA0 · 2018. 6. 1. · Continuous current / rated value 125 A Main circuit Operating power at AC-23 A / at 400 V / at 50/60 Hz / rated value 55 kW at AC-23

Continuous current / rated value 125 A

Main circuitOperating power

● at AC-23 A / at 400 V / at 50/60 Hz / rated value 55 kW

● at AC-23 A / at 500 V / at 50/60 Hz / rated value 75 kW

● at AC-23 A / at 690 V / at 50/60 Hz / rated value 110 kW

Operating voltage

● at AC / at 50/60 Hz / rated value 415 V

Auxiliary circuitNumber of connected NC contacts / for auxiliarycontacts

0

Number of connected NO contacts / for auxiliarycontacts

0

Number of connected CO contacts / for auxiliarycontacts

0

Product feature / interlock No

Short circuitShort-circuit current making capacity (Icm) / forswitch disconnector

● at AC 415 V / without fuse link / acc. to IEC60947-6-1 / rated value / minimum

17 kA

ConnectionsType of electrical connection

● for main current circuit Box terminal

Mechanical DesignHeight 126 mmWidth 309.6 mmDepth 84.5 mmMounting position anyMounting type Screw fixing and standard rail mounting 35 mmMounting type

● front mounting with 4-hole attachment No

● front mounting with central attachment No

● rail mounting Yes

Net weight 2 650 g

Environmental conditionsAmbient temperature

● during operation / minimum -25 °C

● during operation / maximum 70 °C

● during storage / minimum -50 °C

● during storage / maximum 80 °C

3KC0432-2NE00-0AA0 Subject to change without noticePage 2/6 05/17/2018 © Copyright Siemens

Page 3: Data sheet 3KC0432-2NE00-0AA0 · 2018. 6. 1. · Continuous current / rated value 125 A Main circuit Operating power at AC-23 A / at 400 V / at 50/60 Hz / rated value 55 kW at AC-23

CertificatesReference code / acc. to DIN EN 61346-2 Q

General Product Approval Shipping ApprovalMiscellaneous

Further informationInformation- and Downloadcenter (Catalogs, Brochures,…)http://www.siemens.com/lowvoltage/catalogs

Industry Mall (Online ordering system)https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3KC0432-2NE00-0AA0

Service&Support (Manuals, Certificates, Characteristics, FAQs,...)https://support.industry.siemens.com/cs/ww/en/ps/3KC0432-2NE00-0AA0

Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3KC0432-2NE00-0AA0

CAx-Online-Generatorhttp://www.siemens.com/cax

Tender specificationshttp://www.siemens.com/specifications

3KC0432-2NE00-0AA0 Subject to change without noticePage 3/6 05/17/2018 © Copyright Siemens

Page 4: Data sheet 3KC0432-2NE00-0AA0 · 2018. 6. 1. · Continuous current / rated value 125 A Main circuit Operating power at AC-23 A / at 400 V / at 50/60 Hz / rated value 55 kW at AC-23

4.5

46.5 84

66

126

28

56

27

284

7.5 12.8

42

13.4

2.5

13.3

1.5 6.5

44

62

85

35 45

4.5

299

46.5

3KC0432-2NE00-0AA0 Subject to change without noticePage 4/6 05/17/2018 © Copyright Siemens

Page 5: Data sheet 3KC0432-2NE00-0AA0 · 2018. 6. 1. · Continuous current / rated value 125 A Main circuit Operating power at AC-23 A / at 400 V / at 50/60 Hz / rated value 55 kW at AC-23

LIN

E1-1

LOAD

1-2

LOAD

2-4

LOAD

3-6

LIN

E2-3

LIN

E3-5

LIN

E1-7

LIN

E2-9

LIN

E3-1

1

LOAD

1-8

LOAD

2-10

LOAD

3-12

NI

N

NII

N

-Q

3KC0432-2NE00-0AA0 Subject to change without noticePage 5/6 05/17/2018 © Copyright Siemens

Page 6: Data sheet 3KC0432-2NE00-0AA0 · 2018. 6. 1. · Continuous current / rated value 125 A Main circuit Operating power at AC-23 A / at 400 V / at 50/60 Hz / rated value 55 kW at AC-23

3KC0432-2NE00-0AA0 Subject to change without noticePage 6/6 05/17/2018 © Copyright Siemens