BEST PUE LOW INPUT POWER NO AIR LEAKAGE DATA CENTER SOLUTIONS WITH ACOUSTIC PANEL PLENUMS MODELS 150 250 350 450 PATENT PENDING

DATA CENTER - SEMCO is a global leader in air management. · The pumps continue to run as air friction is more detrimental than fluid friction. Data centers are actually large air

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DATA CENTER - SEMCO is a global leader in air management. · The pumps continue to run as air friction is more detrimental than fluid friction. Data centers are actually large air

BEST PUE

LOW INPUT POWER

NO AIR LEAKAGE DATA CENTERSOLUTIONS

WITH ACOUSTIC PANEL PLENUMS

MODELS 150 250 350 450

PATENT PENDING

Page 2: DATA CENTER - SEMCO is a global leader in air management. · The pumps continue to run as air friction is more detrimental than fluid friction. Data centers are actually large air

UNIT CONFIGURATION Feature set includes:

Scavenger side washable mesh filtration Process and scavenger coilScrew chiller technology with patented pumping run around loop configurationElectrically commutative (EC) driven fan arraysProcess side pleated filtrationProcess supply actuated damperElectrically commutative (EC) driven fan arraysBackdraft fan isolation dampers (not pictured)

94˚ Data Center Return

74˚ Data Center Supply

Exhaust Air

Outside AirChiller Evap

Chiller Condenser

SYSTEM PACKAGEBasic market needs for current data center designs are addressed through SEMCO’s simple approach. This system, designed specifically for data centers, incorporates few components with an easy to maintain and logical hydronic coil system achieving a typical annual Power Usage Efficiency (PUE) of 1.122 (based on Washington DC area conditions).

7

12456 3

SYSTEM FEATURES & OPTIONS: • Prepackaged with controls (providing stand-alone water cooled central plant and air handler hybrid)

• Evaporative cooling (available option, but not required for superior PUE compared to all other conditioning systems)

• Shipped in single piece; reduced number of lifts speeds final build

The diagram above shows the basic piping arrangement between the two airstreams. Designed to handle a range of temperature differentials, this high-efficiency system not only rejects heat for the data center, but also starts to economize at an outdoor ambient temperature within 10 degrees of the desired process side leaving air temperature! This is 20-30 degrees warmer (sooner) than other air-to-air competitive options.

1

2

3

4

5

6

7

8

Page 3: DATA CENTER - SEMCO is a global leader in air management. · The pumps continue to run as air friction is more detrimental than fluid friction. Data centers are actually large air

DATA CENTER

PUMP AND REFRIGERATION SYSTEM

PANEL SOLUTIONS FOR SUPERIOR PLENUMS

The key technology to lower PUE and low power input is the use of EC components (fans and pumps); however, the secret is the simple pumping design and screw chiller technology.

The run-around system incorporates high capacity coils and a pump configuration that understands load management under all conditions.

When ambient temperatures are too high and do not create the necessary leaving water temperature, only then does the chiller operate to provide

Key benefits of using modular duct systems include:

• COST EFFECTIVE: Various panel constructions and thicknesses allow us to customize your project and eliminate costly overkill. The need to “stick build” walls and plenums is eliminated.

• EASY INSTALLATION: Roll formed tongue-and-groove construction with a fully enclosed and insulated joint allows for faster installation and a better fit with closer tolerance.

• FIRE RATED & CUSTOM OPTIONS: Fire rating, various metal types, powder coating and finishes are available to customize the system.

supplemental cooling to achieve leaving water and process air temperatures.

In the event that the scavenger supply water is warmer than the process return, the system will transfer into a more traditional dry cooled chiller configuration to prevent overburdening the chiller with its own heat. It should be noted that this only occurs during the few

hours when the outdoor ambient temperature is greater than 90 degrees.

When the outside air has cooler or cold conditions, the scavenger fans reduce in speed to further save energy. The pumps continue to run as air friction is more detrimental than fluid friction.

Data centers are actually large air handling units. The load is placed within this “air handler” and forced air is passed to dissipate heat. SEMCO’s AT-PANL Solutions provide acoustic-thermal plenum systems that are designed to distribute air efficiently, effectively and quietly.

Page 4: DATA CENTER - SEMCO is a global leader in air management. · The pumps continue to run as air friction is more detrimental than fluid friction. Data centers are actually large air

SEMCO embraces a policy of continuous development and improvement, the right is reserved to supply products which may differ from those illustrated and described in this

publication. Certified dimensions will be supplied upon request on receipt of order. PATENT PENDING.

© SEMCO LLC 2017 All Rights Reserved. SEMCO and the SEMCO logo are registered Trademarks of SEMCO LLC.

WE BRINGAIR TO LIFE

WE BRING AIR TO LIFE

SEMCO® is a global leader in air

management. We specialize in the

design and manufacture of a wide

range of air climate and air movement

solutions. Our collective experience

is unrivaled.

Our constant aim is to provide systems that

precisely deliver the best indoor air quality

and performance, as well as maximize

energy efficiency.

SEMCO® A FläktGroup BrandCorporate Headquarters1800 East Pointe Drive

Columbia, Missouri 65201 USA

573 443 1481

[email protected]

To learn more about SEMCO offerings and to contact your nearest representative please visit www.semcohvac.com