Danger of electrical shock, burns or death. Always remove all power sources before aƩempƟng any repair, service or diagnos Ɵc work. Power can be present from shore power, generator, inverter or baƩery. All power sources must be disabled and secured before performing any service. If you lack the skills, tools or equipment to perform diagnos Ɵc or repair work leave such work to an authorized Winnebago Industries dealer or other qualied shop. Copyright © 2012 Winnebago Industries, Inc.

Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

  • Upload
    lyhanh

  • View
    220

  • Download
    5

Embed Size (px)

Citation preview

Page 1: Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

 Danger of electrical shock, burns or death.  Always remove all power sources before a emp ng any repair, service or diagnos c work.  Power can be present from shore power, generator, inverter or ba ery.  All power sources must 

be disabled and secured before performing any service.  

 If you lack the skills, tools or equipment to perform diagnos c or repair work leave such work to an authorized 

Winnebago Industries dealer or other qualified shop. 

Copyright © 2012 Winnebago Industries, Inc. 

Page 2: Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

1 8

ZONE

TWO-PLACE (X.XX)

B

5

1

ANGLE

WHOLE DIM (X)

3

8

4

DSNR

REV

3

2

P.E.

ONE-PLACE (X.X)

D

REV

D

ALL DIMENSIONS ARE IN MILLIMETERS

DATE

TITLE:

CHKR

7

MATERIAL:

B

M.E.

7 4

COPYRIGHT 2011WINNEBAGO

INDUSTRIES, INC.

DO NOT SCALE DRAWING

A

PART NO

THIRD ANGLE

DWGNO

DATE

2

C

FIRST USED

PROJECTION

DFTR

DFTR-ORIG

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

A

5

R

8

6

REVISION RECORD

REF:

C

REV

1

UNSPECIFIED TOLERANCES ARE:

ORIG. DATE

6

OFSHEET

181879-02

181879-01

DRAWING NO. FEATURE

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

WINNEBAGO ONLY

ITASCA ONLY

3

VIEW AA

WIRE ASM-AUX HOLDING TANK151316-01-000

AA

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

CODES/STANDARDS USA

265

1B1

4

1B1

WIN

265

PLATE-WALL,DUAL COAX149557-03-CHTSCREWG39-08-08U (2)

WIRE ASM-COACH181883-01-000

ITA

CODES/STANDARDS-CSA/CMVSS

PANEL-RECEPTACLE151376-03-CHTLABEL-COAX157486-01-CHTPLATE-RCA169065-02-CHTADAPTER082134-01-000NUT082136-01-000SCREWG39-08-12U (4)G11-06-08U (4)

ITA

WIN

1

3

1.5

0.50

NOTES:

ALL WIRES TO BE SECURED WITH CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 EVERY 600MM, USE SCREW G67-XX-XXXOR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

PLACE CROSS LOCATOR ON SENSORS OVER DIMPLES ON TANK.

1.

ROUTE TANK SENSOR WIRES SO THEY DO NOT PASS OVER SENSORS.USE WIRE TIE MOUNT 155366-01-000 AND WIRE TIE 8343-01-000AS NEEDED.TANK SURFACE MUST BE CLEANED USING ISOPROPYLALCOHOL AND PRIMED WITH PRIMER 94.

2.

WIRE PASSES THROUGH FLOOR IN THIS AREA.

3

4

SWITCH-WATER PUMP108357-15-000ACTUATOR108356-03-CHTCIRCUITSAG,JA,AF,JS,JY

401 INVERTER-DC/AC, 1000 WATT

A

13 E35B

WIRING INSTL-BODY,12V

RELEASE

181879

181879

2 PIN HSGTO WATER PUMP

WIRE ASM-MAIN HOLDING TANK151317-01-000

WIRE ASM-WATER TANK151317-01-000

TO COMPT LAMP

3

3

WIRE ASM-CHASSIS (REF)

4

4

5 NOT USED WITH 1D3

5

4

TO SLIDEOUT ROOM

WIRE ASM-AUX HOLDING TANK151316-01-0003

WIRE ASM-MAIN HOLDING TANK151317-01-0003

L01-32

PANEL-RECEPTACLE151376-01-CHTSCREWG39-08-12U (4)

1D3 ENTERTAIN CENTR/EXT TV-DVD

1D3

PORTABLESATELLITE

DISH

INPUT CONNECTIONS

CABLE

12-Jun-2012

Page 3: Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET 2

265

JE

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

RECEPTACLE-12V132958-01-000DETAIL BA

1B1

NE

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

LAMP119258-75-CHTCONNECTOR58028-01-000 (2)SCREWG11-06-10U (2)

DETAIL BA

CODES/STANDARDS-CSA/CMVSS265

CODES/STANDARDS USA1B1

NOTES:

ALL WIRES TO BE SECURED WITH CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 EVERY 600MM, USE SCREW G67-XX-XXXOR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

1.

WIRE PASSES THROUGH FLOOR IN THIS AREA.2

AC HEAT PUMP-2 HI EFFICIENCY29R

A/C ROOF-HI EFF (2) W/EMS276

3 DATA CABLE FOR EMS PANEL PANEL IS MARKED W/RED TAPE.

401 INVERTER-DC/AC, 1000 WATT

13 E35B

WIRING INSTL-BODY,12V

181879

181879

READ-12

SPEAKER-SUBWOOFER124884-01-000GRILL-SUBWOOFER151844-01-CHTSCREWG11-08-12U (4)

LAMP93575-62-CHTBULB117805-02-000 (2)CONNECTOR58028-01-000 (2)SCREWG11-06-10U (2)

276THERMOSTAT135618-03-CHT135618-01-CHTSCREWG13-07-12U (2)

WIRE ASM-OVHD139779-08-000

WIRE ASM-COACHBUTTE

SPLICE

DETAIL BC

MODULE-12V DISCONNECT

CABLE FROM BACKSIDEOF REMOTE PANEL

INVERTER REMOTE PANEL

WB

REMOTE CABLEFROM INVERTER

DETAIL BB

255

SPEAKER94097-01-000 (2)GRILLE173348-01-CHT (2)SCREWG11-08-08U (8)

6 PIN HSGTO SIDEWALL

LO1-32

6 PIN HSGTO SIDEWALL

REMOTE PANEL-INVERTER173337-02-000MODULE-12V DISCONNECT173355-01-000DETAIL BC

401

PANEL-MONITOR,EMS174295-01-000

PANEL-MONITOR134940-06-CHTSCREWG11-08-08U (4)

53D3

255

TO WIRE ASM-ROOFDETAIL FA

SWITCHDETAIL DG

SWITCHESDETAIL DF

SWITCHDETAIL DA

MAIN TV CONNECTORSFROM ROOF

BB

TO IR RECEIVERFROM ROOF

SWITCHDETAIL DB

WIRE ASM-OVHD175158-01-000

2

RADIO/AM/FM/CD/DVD PLAYERSWITCHDETAIL DA

SWITCHDETAIL DL

SWITCHDETAIL DM

SWITCHDETAIL DP

A/C HEAT PUMP-(2) HI EFFICIENCY29R

29R

HTR 110V

WATER

This switch must be onand park brake appliedto perate any slide room.We recommend running theengine to insure adequatebattery power. ON

NOTICERemove room locking bar beforeoperating slide room or damage may occur.

MASTER SLIDE ROOMCONTROL SWITCH

OFF

2/3

E

FRESHWATER

WATERHEATER

GENERATOR

1/3

E

L.P.GAS

LEVELSTEST

STOP

1/3

E

BATTCHG

WATER PUMP

HOLD START UNTILGERERATOR STARTS

1/3

E

F

PILOT OUT

DISPLAY ON WHENGENERATOR RUNS

1/3

2/3

F

PUMP ON

HOURS

2/3

F

BLACKWATER

ON

START

2/3

F

GREYWATER

OFF

HOBBS

LO

THERMOSTAT

AUTO COOL HEAT HI

FAN SPEEDFAN MODE

0N

OFF

!116549-01F

WARNINGCRUSH HAZARD. Keep people and objects clear of the insideand the outside of the slideout room when operating. Failureto comply could result in death or serious injury.

DRIVER'SSIDE REAR

FRONT

REAR

BLACK WASTE LEVEL SELECTOR

PASSENGER'SSIDE REAR

DRIVER'SSIDE FRONT

GALLEY

GRAY WASTE LEVEL SELECTOR

BATH

12-Jun-2012

Page 4: Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET 3NOTES:

L

U

TO WIRE ASM-COACH

TO GROUND BAR

J

3SWITCHDETAIL DC

CONVERTER-55 AMP172246-01-000SCREWG67-10-12U (4)

STUD-ISOLATED86233-01-000NUTD34-06-00USCREWG67-10-12U (2)BOOT77479-02-000

M

SWITCHDETAIL DD

K

DETAIL CC

TO WIRE ASM-CHASSIS

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

2

CODES/STANDARDS USA1B1

SWITCHDETAIL CA

NOTES:

ALL WIRES TO BE SECURED WITH CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 EVERY 600MM, USE SCREW G67-XX-XXXOR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

LCR-1

CONVERTERDETAIL CC

GROMMET8386-01-000

6 SEE WIRING INSTL-TV/DVD FOR ADDITIONAL INFORMATION.

5

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

4 WIRE PASSES THROUGH FLOOR IN THIS AREA.

DETAIL CA

MOUNT SWITCH AND SPACER TO BLOCK ON JAMB,ADJUST HEIGHT TO MATCH MAGNET.

3

CODES/STANDARDS-CSA/CMVSS

SWITCH/MAGNET-STEP, ELECTRIC116995-02-000116995-03-000SCREWG11-06-08U (4)

JAMB-DOOR

1B1

ROUTE WIRESTHRU HOLE

MOUNT MAGNET USING PILOT HOLES IN SCREEN DOOR FRAME,MOUNT WITH MAGNET TOWARD SWITCH.

1.

NEGETIVE BAR140031-01-CHTBOLTC26-06-12U (6)NUTD39-06-00U (6)STUD-ISOLATED86233-01-000 (2)NUTD34-06-00U (2)SCREWG67-10-12U (4)

265

265

2

FOR CONVERTER POSITIONING, SEE DETAIL CD.

5

EXT GRAPHIC/PAINT DLX PKG 1

27G EXTERIOR GRAPHICS PACKAGE #1

EXT FULL BODY PAINT PKG #1

OR OR

27A

26H

26F

24C

EXT FULL BODY PAINT PKG # 2

26H

EXT FULL BODY PAINT PKG # 3

27G

92A

EXT GRAPHIC/PAINT-DLX PKG 2

24C

92A

OR OR

27A

26F

DVD PLAYERS(2)W/LCD MONITORS10C

1D3 ENTERTAIN CENTR/EXT TV-DVD

RELAY-AWNING63912-02-000SCREWG11-08-08U

42B TV,REAR-WITHOUT

13 E35B

WIRING INSTL-BODY,12V

181879

181879

LO2-3

ENTERTAINMENTCTR COMPL-TV173821-05-XXX

1D3

SWITCHESDETAIL DH

LPGD

4

2 PIN HSGTO WIRE ASM-EXT ENT CTRCOAX (GRN/GRN/GRN)CABLE-COMPONENT/COMPOSITE

ET,EUTO REFRIGERATOR

4 PIN HSGTO FURNACE

MAINCONNECTIONTO WIRE ASM-CHASSISDETAIL FC

TO EXT ENT CTRANTENNA 1D3

PLATE-WALL149557-08-CHTSCREW

COAX(ORG/ORG)

DETAIL CB

FROMROOF

SATELLITEDISH

SATELLITE RECEIVER CONNECTION

6

ROUTE RCA & COAX TO BEDROOM TV THROUGH THE ROUTED PATH IN SIDEWALL.7

TO SIDEWALL

12V BREAKER PANELDETAIL DJ

LIGHT-WARDROBE87694-01-000SCREWG11-10-12U (2)CONNECTION58028-01-000 (2)

PLATE-SATELLITE PREPDETAIL CB

PLATE-WALL,RCA167733-01-CHTSCREWG12-06-08U (2)

WALLPLATE,TV76319-09-000

WALLPLATE,TV76319-09-000 (2)

42B

THERMOSTAT135618-04-CHT135618-03-CHTSCREWG13-07-12U (2)

TV-8.5" FLIPDOWN164136-01-000 (2)SCREWG11-08-16U (4)G39-08-40U (4)

CABLE-RCA 12'136860-01-000FOR CONNECTIONSSEE DETAIL GA

10C

10C

TO BE USED FOR TOP BUNK TV.8

TO BE USED FOR BOTTOM BUNK TV.9

8

9

10CSWITCHDETAIL DN

WIRE ASM-SLIDEOUT182144-01-000

L01-32

4

4 PIN HSGTO WATER HEATER

276

A/C ROOF-HIGH EFF(2) W/EMS276

TV(REAR)-26" COLOR STEREO61K

4

29R

WIRE ASM-EXTENSION147053-01-000

29R AC HEAT PUMP-2 HI EFFICIENCY

TV-26"(REF) 61K

RELAY-SLIDEOUT LOCK63912-02-000SCREWG11-08-08U

12-Jun-2012

Page 5: Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET 4NOTES:

DETAIL DF

FOR SWITCH ORIENTATION SEE DETAIL DE

2651B1

1B1 CODES/STANDARDS USA

265 CODES/STANDARDS-CSA/CMVSS

NOTES:

1

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

3

46

2

63

8

5

TOP

7

1

TOP

5

1

7

2

8

4

DETAIL DE

PORCHCEILING SWITCH-ROCKER135740-01-CHT (2)SWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-19-CHTSCREWG11-08-08U (4)

DETAIL DD

PLJF

PJJC

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL DC

YEL-1

YEL-2

1DETAIL DH

PLATE-SWITCH158431-15-CHTSCREWG11-06-10U (6)

SWITCH-STEP108357-19-000CIRCUITSER,ES

LABEL-SLIDEOUT,DRIVER,REAR163992-02-CHT

SWITCH-KEY,SPST-ILLINOIS LCK163097-01-000(CONNECTS TOCIRCUITS DY & DDJ)

PLATE-KEY,SLIDE ROOM163987-01-CHTSCREW76790-05-000 (4)

LABEL-SLIDEOUT,DRIVER,FRONT163992-01-CHT

LABEL-WARNING,SLIDEOUT116549-01-000

LABEL-SLIDROOMCONTROL,MAN163988-01-CHT

WTR HTR-6GAL/ELE/LP/MOTORAID53D

WATER

HTR 110V

SWITCH-ROCKER135740-06-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-35-CHTSCREWG11-08-08U (2)

DETAIL DG

HHJ

53D

SWITCH-COACH BATT108357-18-000ACTUATOR-SWITCH108356-19-CHTCIRCUITSKF,LG,LJ,LH,WC

SWITCH-AWNING108357-06-000ACTUATOR-SWITCH108356-12-CHTCIRCUITSFFD,FFR,FFE,FFE,JJR,FFD

SWITCH-CHASSIS BATTERY108357-18-000ACTUATOR-SWITCH108356-20-CHTCIRCUITSUUC,TTY,UUBUUB,TTZ,MK

13 E35B

WIRING INSTL-BODY,12V

181879

181879

SWITCH-PUMP108357-15-000ACTUATOR108356-23-CHTPLATE98351-07-CHTSCREWG11-06-10U (2)

CEILING SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-07-CHTSCREWG11-08-08U (2)

DETAIL DB

JGPE

SWITCH108357-06-000ACTUATOR108356-24-CHTCIRCUITSBBM,DT,BBN,BBA,DDJ,BBA

SWITCH108357-06-000ACTUATOR108356-24-CHTCIRCUITSDR,DT,DU,BBA,DDJ,BBA

KNURLED NUT(SUPPLIED WITHCIRCUIT BREAKER)HEX

NUT-PALNUT(SUPPLIED WITHCIRCUIT BREAKER)

BUSS BAR

PLATE

VIEW DK-DK

5.0

DETAIL DA(2 PLACES)

15

LABEL92547-06-000

JD

LAMPS

DKJE

LAMPS

SCREWG52-06-04U (12)

LAMPS

LAMPS

CIRCUIT BREAKER93654-01-000 (2)

DETAIL DJ(BACK VIEW)

CIRCUIT BREAKER93654-02-000 (8)

BUSS BAR92786-03-000 (2)

15

DK

(PUSH TO RESET)

M6 BLK

HOUSING 12V CIRCUIT BREAKERS

6

WB

SCREWG11-10-12U (4)

6

JG

REFRIG

SCREWG39-08-06U (2)

15

ET

LAMPS

PLATE139067-01-CHT

M8 BLK

15

JF

FRONTFURNACE/EXH FAN

15

JB

COMPTLAMPS

15

JCWC

MONITOR/TV

15 15

LPDETECTOR

JA

DETAIL DJ(FRONT VIEW)

LABEL-SLIDEOUTPASS,REAR163992-03-CHT

SWITCH108357-06-000ACTUATOR108356-24-CHTCIRCUITSLLZ,DT,MMC,BBA,DDJ,BBA

CEILING SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-07-CHTSCREWG11-08-08U (2)

DETAIL DM

JDKKR

BLACK WASTE LEVEL SELECTOR

SWITCH-ROCKER135740-02-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-61-CHTSCREWG11-08-08U (2)

DETAIL DL

GRAY WASTE LEVEL SELECTOR

SWITCH-ROCKER135740-02-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-52-CHTSCREWG11-08-08U (2)

DETAIL DP

TV SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-45-CHTSCREWG11-08-08U (2)

DETAIL DN

JCEX

DVD PLAYERS(2)W/LCD MONITORS10C

10C

JA

JP

IN

OUT

AWNING

This switch must be onand park brake appliedto perate any slide room.We recommend running theengine to insure adequatebattery power. ON

NOTICERemove room locking bar beforeoperating slide room or damage may occur.

MASTER SLIDE ROOMCONTROL SWITCH

OFF

!116549-01F

WARNINGCRUSH HAZARD. Keep people and objects clear of the insideand the outside of the slideout room when operating. Failureto comply could result in death or serious injury.

DRIVER'SSIDE REAR

PASSENGER'SSIDE REAR

DRIVER'SSIDE FRONT

WATERPUMP

12-Jun-2012

Page 6: Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET 5

1B1

CODES/STANDARDS-CSA/CMVSS265

1B1

CODES/STANDARDS USA

265

LOSN3

LOSN3 LO2-34

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

1

DETAIL EA

2 PIN HOUSINGFROM WIRE ASM-ROOF3 PIN HOUSING

FROM WIRE ASM-ELEVATION SENSOR

NOTES:

SENSOR SUPPLIED WITH SATELLITE ASSEMBLY.1

SATELLITEELEVATIONSENSORDETAIL EA

255

255SPEAKER-ROUND,CEILING160867-01-CHT (2)SCREWG1208-12-170 (8)

RADIO/AM/FM/CD/DVD PLAYER

13 E35B

WIRING INSTL-BODY,12V

181879

181879

LOSN3

G GND R 12VWBG GND R 12VWB

12-Jun-2012

Page 7: Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET 6

ANT-5

ADAPTER82134-01-000 (5)

CABLE ASM-COAX(GRN,YEL,RED,GLD,ORG/ORG)

CABLE ASM-COAX(GRN,YEL,RED,GLD,ORG/ORG)

FROM WIRE ASM-ROOF FROM WIRE ASM-COACH

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

NOTES:

CONNECT THE ORANGE COAX FROM ROOF ASM TO ONE OF THE 2 GRAY COAX CABLES ON THE SATELLITE DISH, THE OTHER GRAY COAX IS NOT USED.

2

SATELLITE TV SYSTEM MANUAL48Q

DM-2 48Q2

DETAIL FA

13 E35B

WIRING INSTL-BODY,12V

181879

181879WRAP LEGS AROUND ANTENNA BASE.1

ENTERTAIN CENTR/EXT TV-DVD1D3

ANT-R 1D3

SEAL

FB

VIEW FB

JPFROM WIRE ASM-ROOF

BRACKET ANTENNAGROUND 1

CABLE ASM-COAX(GRN/GRN)

FROM WIRE ASM-SLIDEOUT

DETAIL FC

CABLE ASM-COAX(GRN/GRN/GRN)

FROM WIRE ASM-SLIDEOUT

CABLE ASM-COAX(GRN)

FROM WIRE ASM-COACH

ADAPTER82134-01-000

CABLE ASM-COAX(ORG/ORG)

FROM WIRE ASM-SLIDEOUT

CABLE ASM-COAX(ORG/ORG)

SPLITTER-3 WAY86756-02-000SCREWG11-08-12U (2)

CABLE ASM-COAX(GRN)

FROM WIRE ASM-COACH FROM WIRE ASM-SLIDEOUT

12-Jun-2012

Page 8: Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

1B1

265

10C

10C

265

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

DVD PLAYER W/7" MONITOR

1B1

NOTES:

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET 7

13 E35B

WIRING INSTL-BODY,12V

181879

181879

WIRE ASM-SLIDEOUT

DETAIL GA

AV INPUT CABLE(AV1) NOT USED

NC

TV-FLIP DOWN(TOP BUNK)(PRIMARY PLAYER)

BLK

RED

AV OUTPUT CABLE

NC

AV INPUT CABLE(AV1) NOT USED

YEL

EX

RED

YELBLK

AV OUTPUT CABLENOT USED

WIRE ASM-SLIDEOUT

TV-FLIP DOWN(BOTTOM BUNK)(SECONDARY PLAYER)

EX

THREE WAY RCA CABLEROUTED WITH 12V WIRINGCONNECTS AS SHOWN YEL TO YELWHT TO WHT & RED TO RED

2.

REMOVE SHIPPING RESTRAINT SCREWS FROM DVD PLAYER.

1.

REMOTE IR RECEIVER SUPPLIED WITH DVD PLAYER,TO BE MOUNTED IN BOTTOM BUNK.

3.

ALL WIRES ARE TO SECURED WITH CLAMP10495 OR 10497 OR WIRETIE 8343 OR 104046 EVERY 600 MM, USE SCREWS G64-XX-XXXOR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

12-Jun-2012

Page 9: Danger of electrical shock, burns or death. Always remove ... · PDF fileof remote panel inverter remote panel wb ... to ir receiver from roof switch detail db ... for converter positioning,

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

13 E35B

WIRING INSTL-BODY,12V

181879

1818798

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

HA

VIEW HA

6 PIN HSGWITH BLUE TAPE

LLP

6 PIN HSGWITH BROWN TAPE

XXV

6 PIN HSGWITH GREEN TAPE

6 PIN HSGWITH LIGHTYELLOW TAPE

CONTROL-SLIDEOUT,IN-WALL REAR LEFT178451-01-000SCREWG39-08-12U (4)

LLL

LLZ

CONTROL-SLIDEOUT,IN-WALL FRONT LEFT178451-01-000SCREWG39-08-12U (4)

DU MMC

6 PIN HSGWITH PURPLE TAPE

DR

CONTROL-SLIDEOUT,IN-WALL REAR RIGHT178451-01-000SCREWG39-08-12U (4)

LLR

BBN

XXW

LLK

BBM

6 PIN HSGWITH YELLOW TAPE

CLAMP-CABLE10495-02-000 (2)

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

1900 DROPTO SLIDEOUTREAR MOTOR(GRN)

1900 DROPTO SLIDEOUTREAR MOTOR(PUR)

1900 DROPTO SLIDEOUTFRONT MOTOR(LT YEL)

1900 DROPTO SLIDEOUTREAR MOTOR(BRN)

1900 DROPTO SLIDEOUTFRONT MOTOR(YEL)

1900 DROPTO SLIDEOUTFRONT MOTOR(BLU)

CLAMP-CABLE10495-02-000 (4)

GROMMET016188-11-000 (6)

EXTM

OTO

R 2

MO

TOR

1

GND

PWR

RET

EXTM

OTO

R 2

MO

TOR

1

GND

PWR

RET

EXTM

OTO

R 2

MO

TOR

1

GND

PWR

RET

12-Jun-2012