8
Danger of electrical shock, burns or death. Always remove all power sources before aƩempƟng any repair, service or diagnos Ɵc work. Power can be present from shore power, generator, inverter or baƩery. All power sources must be disabled and secured before performing any service. If you lack the skills, tools or equipment to perform diagnos Ɵc or repair work leave such work to an authorized Winnebago Industries dealer or other qualied shop. Copyright © 2012 Winnebago Industries, Inc.

Danger of electrical shock, burns or death. Always remove ...4 standardized length, check with engineering before changing. drawing no. models p36m 177787-01 177787-02 p40l,p40u sheets

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Danger of electrical shock, burns or death. Always remove ...4 standardized length, check with engineering before changing. drawing no. models p36m 177787-01 177787-02 p40l,p40u sheets

 Danger of electrical shock, burns or death.  Always remove all power sources before a emp ng any repair, service or diagnos c work.  Power can be present from shore power, generator, inverter or ba ery.  All power sources must 

be disabled and secured before performing any service.  

 If you lack the skills, tools or equipment to perform diagnos c or repair work leave such work to an authorized 

Winnebago Industries dealer or other qualified shop. 

Copyright © 2012 Winnebago Industries, Inc. 

Page 2: Danger of electrical shock, burns or death. Always remove ...4 standardized length, check with engineering before changing. drawing no. models p36m 177787-01 177787-02 p40l,p40u sheets

CODES/STANDARDS USA

ZONE

TWO-PLACE (X.XX)

B

5

1

ANGLE

WHOLE DIM (X)

3

8

4

DSNR

REV

3

2

P.E.

ONE-PLACE (X.X)

D

REV

D

ALL DIMENSIONS ARE IN MILLIMETERS

DATE

TITLE:

CHKR

7

MATERIAL:

B

M.E.

7 4

COPYRIGHT 2011WINNEBAGO

INDUSTRIES, INC.

DO NOT SCALE DRAWING

A

PART NO

THIRD ANGLE

DWGNO

DATE

2

C

FIRST USED

PROJECTION

DFTR

DFTR-ORIG

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

A

5

R

8

6

REVISION RECORD

REF:

C

REV

1

UNSPECIFIED TOLERANCES ARE:

ORIG. DATE

6

OFSHEET

3

1 7

3

0.50

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

1

1.5

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

CODES/STANDARDS-CSA/CMVSS

1B1

265

1B1

265

NOTES:

SEE LEVELING SYSTEM INSTL FOR ADDITIONAL INFORMATION.

SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.2

1

SEE WIRING INSTL-FRONT END FOR ADDITIONAL INFORMATION.3

A

12 P-SERIES

BATTERY INSTL

RELEASE

177787

177787

RESIDENTIAL REFRIGERATOR PKG15L

4 STANDARDIZED LENGTH, CHECK WITH ENGINEERING BEFORE CHANGING.

MODELSDRAWING NO.

P36M

177787-01

177787-02

P40L,P40U

SHEETS

1,2,3

1,4,5

2

2

1

2

3

2

15L

P36M P40L/P40U P42E

CABLE ASM (YEL) FROM COACH BATTERY TO COACH STUD,JUMP START 175207-52-068 175207-52-076 175207-52-090

CABLE ASM (YEL) FROM STUD,JUMP START TO COACH SIDE OF AUX START SOLENOID 175207-52-013 175207-52-009 175207-52-006

CABLE ASM (BLK) FROM STUD,JUMP START "GROUND" TO FRAME RAIL GROUND 175211-01-005 175211-01-005 175211-01-008

CABLE ASM (YEL) FROM COACH SIDE OF AUX START SOLENOID TO COACH BATTERY DISCONNECT 141416-52-004 141416-52-004 141416-52-004

CABLE ASM (ORG) FROM COACH BATTERY TO INVERTER FUSE 175207-62-010 175207-62-010 175207-62-010

CABLE ASM (ORG) FROM INVERTER FUSE TO INVERTER POSITIVE TERMINAL 175207-62-023 175207-62-035 175207-62-032

CABLE ASM (BLK) FROM BATTERY TO INVERTER NEGATIVE TERMINAL 175211-01-028 175211-01-040 175211-01-034

CABLE ASM (BLK) FROM COACH BATTERY TO FRAME RAIL GROUND 175211-02-060 175211-02-073 175211-02-081

CABLE ASM (PUR) FROM CHASSIS BATTERY DISCONNECT TO CHASSIS ISOLATED STUD 175207-15-008 175207-15-010 175207-15-010

CABLE ASM (BLU) FROM CHASSIS ISOLATED STUD TO LEVELING SYSTEM PUMP 141416-21-108 141416-21-115 141416-21-129

CABLE ASM (BLK) FROM LEVELING SYSTEM TO FRAME RAIL GROUND 133567-11-005 133567-11-005 133567-11-005

CABLE ASM (GRN) FROM COACH BAT DISC RELAY TO PASS THRU STUD IN FRONT LEFT COMPT 175207-42-115 175207-42-120 175207-42-135

CABLE ASM (GRN) FROM PASS THRU STUD IN FRONT LEFT COMPT TO GENERATOR 175207-42-025 175207-42-025 175207-42-025

CABLE ASM (BLK) FROM GENERATOR TO FRAME RAIL GROUND BOLT 175211-02-013 175211-02-013 175211-02-013

CABLE ASM (YEL) JUMPER BETWEEN POSITIVE POSTS ON COACH BATTERY

141417-52-004

141417-51-002 (2)

141417-51-002 (4)

141417-52-004

141417-51-002 (2)

141417-51-002 (4)

141417-52-004

141417-51-002 (2)

141417-51-002 (4)

CABLE ASM (BLK) JUMPER BETWEEN NEGATIVE POSTS ON COACH BATTERY

133568-12-004

133568-11-002 (2)

133568-11-002 (4)

133568-12-004

133568-11-002 (2)

133568-11-002 (4)

133568-12-004

133568-11-002 (2)

133568-11-002 (4)

CABLE ASM (RED) JUMPER BETWEEN POSITIVE POSTS IN LEFT FRONT COMPT 141417-32-002 141417-32-002 141417-32-002

CABLE ASM-TEMPERATURE,BATTERY 175385-03-000 175385-03-000 175385-03-000

CABLE ASM (RED) FROM CHASSIS BATTERY TO CHASSIS SIDE OF AUX START SOLENOID 175207-35-015 175207-35-013 175207-35-009

4

15L

15L15L

REFRIGERATOR-4 DOOR79W

79W

79W

79W

79W

79W

79W

79W

79W

1

79W

79W

79W

79W

15L

15L

15L

15L15L

15L

15L

15L

P42E177787-03 1,6,7

1/18/2012

Page 3: Danger of electrical shock, burns or death. Always remove ...4 standardized length, check with engineering before changing. drawing no. models p36m 177787-01 177787-02 p40l,p40u sheets

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET 2

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

2651B1

CODES/STANDARDS-CSA/CMVSS265

1B1

12 P-SERIES

BATTERY INSTL

177787

177787

CA

CB

CABLE ASM (GRN)FROM COACH BAT DISCRELAY TO PASS THRU STUD

CABLE ASM (GRN)GENERATER FROM PASSTHRU STUD TO GENERATOR

CABLE ASM (BLK)GENERATOR GROUNDFROM GENERATOR GROUND STUDTO LEVEL SYSTEM GROUND STUD

CABLE ASM (BLU)FROM ISOLATED STUDIN REAR CHASSIS BREAKER PANELTO LEVEL SYSTEM PUMP

CABLE ASM (BLK)FROM BATTERYGROUND POSTTO INVERTER

DETAIL CA

CABLE ASM (ORG)FROM FUSE BLOCKTO INVERTER

CABLE ASM-TEMP SENSORFROM BATTERY GROUND POSTTO INVERTER

DETAIL CA

CABLE ASM (YEL)FROM COACH BATTERYTO STUD,JUMP START

GENERATOR(REF)

CABLE ASM (RED)JUMPER BETWEENPOSITIVE POSTS

GROMMET23942-02-000

1/18/2012

Page 4: Danger of electrical shock, burns or death. Always remove ...4 standardized length, check with engineering before changing. drawing no. models p36m 177787-01 177787-02 p40l,p40u sheets

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET 3

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS-CSA/CMVSS

2651B1

265

CODES/STANDARDS USA1B1

12 P-SERIES

BATTERY INSTL

177787

177787

VIEW CA

VIEW CB

HOLDER-FUSE115187-02-000FUSE-400 AMP115187-05-000SCREWG39-10-16B (2)

BATTERY-12V (2)(CHASSIS SUPPLIED)

BOLT51387-06-000 (2)NUT-HEXD39-05-00U (2)NUT-SPEED44364-02-000 (2)

BATTERY-12V174923-01-000 (2)BOLT51387-06-000 (2)NUT-HEXD39-05-00U (2)NUT-SPEED44364-02-000 (2)STRAP-BATTERYTIE DOWN138914-01-CHT (2)

CABLE ASM (YEL)COACH BATTERY JUMPER

CABLE ASM (BLK)COACH BATTERY JUMPER

CABLE ASM (ORG)TO INVERTER FUSE

CABLE ASM (YEL)

TO GROUND STUDBEHIND CHASSISBATTERIES

CABLE ASM-TEMPERATURE,BATTERY

CABLE ASM (BLK)TO INVERTER

COACH BATTERYDISCONNECT

AUX STARTSOLENOID

CHASSISSUPPLIED CABLES

CABLE ASM (PUR)

CABLE ASM (GRN)

NOTES:

SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.1

1

1

RELAY-BATTERYDISCONNECT86273-02-000

STUD-ISOLATED(REF)

INVERTER/CHARGER 2.0 KW13X

CONNECT JUMPER CABLES TO MIDDLE BATTERIES WITH2 13X

BATTERY HOLDDOWN(CHASSIS SUPPLIED)

CABLE ASM (YEL)

2

2

2

15L

TRAY ASM-BATTERY176166-01-CHT (2)NUTD39-06-009 (6)WASHERE13-17-00B (6)

GROMMET23942-02-000 (2)

GROMMET23942-02-000

CABLE ASM (YEL)

CABLE ASM (BLK)

STUD-JUMP START,RED175636-01-000

STUD-JUMP START,BLACK175636-02-000

LABEL-JUMP START,COACH176543-01-CHT

RESIDENTIAL REFRIGERATOR PKG15L

BATTERY-12V174923-01-000 (4)BOLT51387-06-000 (6)NUT-HEXD39-05-00U (6)NUT-SPEED44364-02-000 (6)STRAP-BATTERYTIE DOWN138914-01-CHT (4)

1/18/2012

Page 5: Danger of electrical shock, burns or death. Always remove ...4 standardized length, check with engineering before changing. drawing no. models p36m 177787-01 177787-02 p40l,p40u sheets

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

12 P-SERIES

BATTERY INSTL

177787

1777874

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

CABLE ASM (BLK)GENERATOR GROUNDFROM GENERATOR GROUND STUDTO LEVEL SYSTEM GROUND STUD

CABLE ASM (GRN)GENERATER FROM PASSTHRU STUD TO GENERATOR

CABLE ASM (ORG)FROM FUSE BLOCKTO INVERTER

CABLE ASM (RED)JUMPER BETWEENPOSITIVE POSTS

CABLE ASM-TEMP SENSORFROM BATTERY GROUND POSTTO INVERTER

DETAIL EA

GROMMET23942-02-000

CABLE ASM (GRN)FROM COACH BAT DISCRELAY TO PASS THRU STUD

CABLE ASM (BLU)FROM ISOLATED STUDIN REAR CHASSIS BREAKER PANELTO LEVEL SYSTEM PUMP

CABLE ASM (YEL)FROM COACH BATTERYTO STUD,JUMP START

CABLE ASM (BLK)FROM BATTERYGROUND POSTTO INVERTER

DETAIL EA

GENERATOR(REF)

CA

EB

GROMMET23942-02-000

1/18/2012

Page 6: Danger of electrical shock, burns or death. Always remove ...4 standardized length, check with engineering before changing. drawing no. models p36m 177787-01 177787-02 p40l,p40u sheets

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

12 P-SERIES

BATTERY INSTL

177787

1777875

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

RELAY-BATTERYDISCONNECT86273-02-000

CABLE ASM (YEL)

GROMMET23942-02-000

LABEL-JUMP START,COACH176543-01-CHT

STUD-JUMP START,RED175636-01-000

CABLE ASM (GRN)

BATTERY-12V (2)(CHASSIS SUPPLIED)TIEDOWN-BATTERY(CHASSIS SUPPLIED)

COACH BATTERYDISCONNECT

CABLE ASM (PUR)

STUD-JUMP START,BLACK175636-02-000

CABLE ASM (YEL)

CHASSISSUPPLIED CABLE

CABLE ASM (BLK)

GROMMET23942-02-000 (2)

BOLT51387-06-000 (2)NUT-HEXD39-05-00U (2)NUT-SPEED44364-02-000 (2)

BATTERY HOLDDOWN(CHASSIS SUPPLIED)

1

1

VIEW EB

AUX STARTSOLENOID

STUD-FEED THRU118499-01-000

NOTES:

SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.1

GROMMET23942-01-000

CABLE ASM (RED)

CHASSISSUPPLIED CABLE

CHASSISSUPPLIED CABLE

1/18/2012

Page 7: Danger of electrical shock, burns or death. Always remove ...4 standardized length, check with engineering before changing. drawing no. models p36m 177787-01 177787-02 p40l,p40u sheets

CABLE ASM (YEL)FROM COACH BATTERYTO STUD,JUMP START

CABLE ASM (GRN)GENERATER FROM PASSTHRU STUD TO GENERATOR

CABLE ASM (GRN)FROM COACH BAT DISCRELAY TO PASS THRU STUD

CABLE ASM (BLU)FROM ISOLATED STUDIN REAR CHASSIS BREAKER PANELTO LEVEL SYSTEM PUMP

CABLE ASM (RED)JUMPER BETWEENPOSITIVE POSTS

GROMMET23942-02-000

GENERATOR(REF)

CABLE ASM (BLK)GENERATOR GROUNDFROM GENERATOR GROUND STUDTO LEVEL SYSTEM GROUND STUD D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET 6

12 P-SERIES

BATTERY INSTL

177787

177787

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

CA

GA

1/18/2012

Page 8: Danger of electrical shock, burns or death. Always remove ...4 standardized length, check with engineering before changing. drawing no. models p36m 177787-01 177787-02 p40l,p40u sheets

BOLT51387-06-000 (2)NUT-HEXD39-05-00U (2)NUT-SPEED44364-02-000 (2)

BATTERY HOLDDOWN(CHASSIS SUPPLIED)

STUD-JUMP START,RED175636-01-000

STUD-JUMP START,BLACK175636-02-000

GROMMET23942-02-000 (6)

CABLE ASM (GRN)

BATTERY-12V (2)(CHASSIS SUPPLIED)TIEDOWN-BATTERY(CHASSIS SUPPLIED)

CABLE ASM (RED)

CABLE ASM (BLK)

CHASSISSUPPLIED CABLE

CABLE ASM (PUR)

CABLE ASM (YEL)

RELAY-BATTERYDISCONNECT86273-02-000

LABEL-JUMP START,COACH176543-01-CHT

CABLE ASM (YEL)

CHASSISSUPPLIED CABLE

AUX STARTSOLENOID(REF)

COACH BATTERYDISCONNECT(REF)

STUD-FEED THRU118499-01-000SCREWG39-10-12U (4)

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

12 P-SERIES

BATTERY INSTL

177787

1777877NOTES:

SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.1

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265VIEW GA

COACH BATTERYGROUND

CABLE ASM (BLU)

CABLE ASM (YEL)

1

1

BRACKET168591-08-CHTSCREWG39-10-12U (4)

1/18/2012