521B0850 DKCFN.PD.013.FA5.02 01-2008 DATA SHEET Water Pumps APP0.6 - 3.5 1. General information APP0.6, APP1.0, APP1.5, APP1.8, APP2.2, APP2.5, APP3.0 and APP3.5 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater reverse osmosis filtration applications and for high pressure salt water pumping. The pumps are based on the axial piston principle enabling a very light and compact design, and they are designed so that lubrication of the moving parts in the pumps is provided by the fluid itself. No oil lubrication is thus required. All parts included in the pumps are designed to provide long service life, i.e. long service life with a constantly high efficiency and minimum of service required. The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement, regardless of any counter-pressure. 2. Benefits One of the smallest and lightest pumps on the market. Can be powered by a combustion engine provided that a special coupling is used. Generates insignificant pulsations in the pressure line. No preventive maintenance required (no periodic service like e.g. change of lubricant and wearing parts). Long service life. Danfoss guarantees 8000 hours maintenance-free operation. All parts of the pump are made of non corrosive materials eg. Duplex (SAF 2205/EN1.4462) and Super-duplex (SAF 2507/EN1.4410) stainless steel and carbon reinforced PEEK. High efficiency. 1: Shaft sealing 2: Mounting flange 3: Bleeding plugs 4: Retaining ring 5: Piston/shoe 6: Valve plate 7: Swash plate 8: Cylinder barrel 9: Spring 10: Port plate 11: Connecting flange 12: Housing with bearing 2 4 5 1 3 11 12 6 7 8 10 9

Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0850 DKCFN.PD.013.FA5.02 01-2008

DATA SHEETWater Pumps

APP0.6 - 3.5

1. General information

APP0.6, APP1.0, APP1.5, APP1.8, APP2.2, APP2.5, APP3.0 and APP3.5 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater reverse osmosis filtration applications and for high pressure salt water pumping.

The pumps are based on the axial piston principle enabling a very light and compact design, and they are designed so that lubrication of the moving parts in the pumps is provided by the fluid itself. No oil lubrication is thus required.

All parts included in the pumps are designed to provide long service life, i.e. long service life with a constantly high efficiency and minimum of service required.

The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement, regardless of any counter-pressure.

2. Benefits• Oneofthesmallestandlightestpumpsonthemarket.• Can be powered by a combustion engine provided that a special coupling is used.• Generatesinsignificantpulsationsinthepressureline.• Nopreventivemaintenancerequired(noperiodicservicelikee.g.changeoflubricantandwearingparts).• Longservicelife.Danfossguarantees8000hoursmaintenance-freeoperation.• Allpartsofthepumparemadeofnoncorrosivematerialseg.Duplex(SAF2205/EN1.4462)and Super-duplex(SAF2507/EN1.4410)stainlesssteelandcarbonreinforcedPEEK.• Highefficiency.

1: Shaftsealing 2: Mounting flange 3: Bleeding plugs4: Retainingring5: Piston/shoe 6: Valve plate7: Swashplate 8: Cylinder barrel9: Spring10: Port plate11: Connecting flange12: Housingwithbearing

2

45

1 311

12

6 78

10 9

Page 2: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

2 DKCFN.PD.013.FA5.02 521B0850

0

0,5

1

1,5

2

2,5

3

3,5

4

500 1000 1500 2000 2500 3000 3500

rpm

m3 /h

3. Technical dataCode number 180B3001 180B3002 180B3026 180B3003 180B3004 180B3000 180B3030 180B3032

APP pumps APP0.6 APP1.0 APP1.5 APP1.8 APP2.2 APP2.5 APP3.0 APP3.5

Geometricdisplacementcm3/rpm(in3/rpm)

4(0.24)

6.3(0.38)

9.3(0.56)

10(0.61)

12.5(0.76)

15.3(0.93)

17.7(1.08)

20.5(1.25)

Flow(3000rpm) 1)m3/h(gpm)

0.6(2.6)

1.0(4.4)

1.5(6.6)

1.7(7.5)

2.1(9.2)

2.6(11.4)

3.0(13.2)

3.5(15.4)

Min. pressure 2)bar (psi)

20290

20290

20290

20290

20290

20290

20290

20290

Max. pressure, cont. 3)bar

(psi)80

(1160)80

(1160)80

(1160)80

(1160)80

(1160)80

(1160)80

(1160)80

(1160)

Max. pressure, intermittent4)bar (psi)

100(1450)

100(1450)

100(1450)

100(1450)

100(1450)

100(1450)

100(1450)

100(1450)

Max. speed cont. 5) rpm 3450 3450 3450 3450 3450 3000 3000 3000

Min. speed cont. rpm 700 700 700 700 700 700 700 700

Power requirement at 80 bar and 3000 rpm:

kW(hp)

1.9(2.5)

2.9(3.9)

4.5(6)

4.8(6.3)

6.0(7.9)

7.2(9.6)

8.4(11.3)

9.8(13.1)

Weightkg(lb)

5.2(9.7)5.2(9.7)

8,6(17)

8.6(17.0)

8.6(17.0)

8.6(17)

8.6(17.0)

8.6(17)

Integrated flushing valve NO NO NO NO NO NO YES YES

Flowthroughflushingvalveat1 bar pressure drop

m3/h(gpm)

- - - - - -0.8(3.7)

0.8(3.7)

1) Typicalaverageflowat80bar. 4) Intermittent pressure is acceptable for less than2) Forlowerpressure,pleasecontactDanfossROSalesOrganization. 10 seconds per minute. 3) Forhigherpressure,pleasecontactDanfossROSalesOrganzation. 5) Forspeedsabove3000rpmthepumpmustbe boostedatapressureof2-5bar(29.0-72.5psi).

4. Flow at different rpmUsing the diagram shown below, it is easy to select the pump which fits the application best if the flow required and the rotation speed(rpm)ofthepumpareknown.

Furthermore,thisdiagramshowsthattheflowcanbechangedbychangingtherotationspeedofthepump.Theflow/rpmratioisconstant, and the “desired “ flow can be obtained by changing the rotation speed to a corresponding value. Thus, the required rpm can be determined as: Desiredflow×Ratedrpm Requiredrpm= Ratedflow

APP1.8

APP1.0

APP0.6

APP2.2

APP1.5

APP2.5

APP3.5

APP3.0

Page 3: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0850 DKCFN.PD.013.FA5.02 3

5. Power requirements

Pump model Flow Pressure rpm Calc. factor

60 bar 70 bar 80 bar

l/min m3/h gpm 870 psi 1015 psi 1160 psi

APP0.6 10.2 0.61 2.69 1.38 kW 1.61 kW 1.84kW 2840 475.8

APP0.6 12.3 0.74 3.25 1.66kW 1.94kW 2.21kW 3400 475.8

APP1.0 16.53 0.99 4.37 2.14kW 2.49kW 2.85 kW 2840 474.6

APP1.0 19.83 1.19 5.24 2.57kW 2.99kW 3.42kW 3400 474.6

APP1.5 25.11 1.51 6.63 3.21kW 3.75kW 4.29kW 2890 468.6

APP1.5 30.17 1.81 7.97 3.86kW 4.51kW 5.15kW 3470 468.6

APP1.8 26.78 1.61 7.07 3.43kW 4.00kW 4.57kW 2890 463.2

APP1.8 32.18 1.93 8.50 4.12kW 4.81kW 5.49kW 3470 463.2

APP2.2 33.48 2.01 8.84 4.29kW 5.00kW 5.71kW 2900 468.6

APP2.2 40.22 2.41 10.63 5.15kW 6.01kW 6.87kW 3480 468.6

APP2.5 41.94 2.52 11.08 5.07kW 5.92kW 6.77kW 2900 484.8

APP3.0 48.2 2.9 12.7 6.2 kW 7.2kW 8.2 kW 2930 470.0

APP3.5 56.0 3.4 14.8 7.2kW 8.4kW 9.6 kW 2930 470.0

The power requirements can be determined using one of the following guiding equations:

l/min×bar 16.7×m3/h×bar 0.26×gpm×psiRequiredpower= [kW]or [kW]or [kW] Calc. factor Calc. factor Calc. factor

6. Inlet pressureWatersupplytothepumpiseithermadefromatankplacedabovethepumpordirectlyfromafeedpump.Thepressureatthepumpinlet(I)mustbeintherange:0.5-5bar(7 3-72.5psi).

7. Temperature and corrosion7.1 Operation: • Fluidtemperature: +3°Cto+50°C(+37.4°Fto122°F)-dependentontheNaClconcentration• Ambienttemperature: +3°Cto+50°C(+37.4°Fto122°F)

The chart below illustrates the corrosive resistance of different types of stainless steel related to NaCl concentration and temperature. AllcriticalpartsoftheAPPwaterpumpismadeofSAF2507.If the water pump is operated at high salinity, always flush the water pump with fresh water at operation stop in order to minimise theriskofcrevicecorrosion.

NaCl vs. temperature

7.2 Storage: • Storagetemperature: -40°Cto+70°C(+37.4°Fto122°F)–providedthatthepumpisdrainedoffluidandstored

”plugged”.

Antefreezeprotectionisrequiredattemperaturesbelow2°C.DanfossrecommendsusingDowcalNfromDowChemicalCompany or Chillsafe mono propylene glycol from Arco Chemical Company.

904L / SAF 2205

1hp = 0.75kW1kW = 1.34hp1gpm= 3.79l/min1l/min= 0.26gpm1 m3/h= 4.40gpm1gpm= 0.23m3/h

Page 4: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

4 DKCFN.PD.013.FA5.02 521B0850

8. Noise levelThe table indicates the approximatenoiselevelindB(A)measuredatadistanceof1mfromthepumpinareverberation room.

Type 60 bar (870 psi)1500 rpm

60 bar (870 psi)3000 rpm

APP0.6 70 73

APP1.0 73 75

APP1.5 75 76

APP1.8 75 76

APP2.2 75 76

APP2.5 76 77

APP3.0 72 77

APP3.5 72 77

Generally,noisewillbereducedifspeedisreducedandviceversa.Useflexiblehosesinordertominimizevibrationsandnoise.

Sincethepumpistypicallymountedonabellhousingorframe,thenoiselevelcanonlybedeterminedforthecompleteunit(system).

Itisthereforeveryimportantthatthepumpismountedcorrectlyonaframewithdamperstominimizevibrationsandnoise.

The noise level is influenced by:•Thespeedofthepump,highrpmcreatemorenoisethanlowrpm•Rigidmountingofthepumpgeneratesmorenoisethanflexiblemounting•Pipemountingdirecttothepumpincreasesthenoiselevelcomparedtoaflexiblehose 9. FiltrationAswaterhasverylowviscosity,theAPPpumpshavebeendesignedwithverynarrowclearanceinordertocontrolinternalleakageratesandimprovecomponentperformance.Thereforeitisimportantthattheinletwaterisfilteredproperlytominimizethewearofthe pump.

Themainfiltermusthaveafiltrationefficiencyof99.98%at10µm.Werecommendthatyouuseprecisiondepthfiltercartridgesrated10µmabs.ß10>5000(equivalenttoafiltrationefficiencyof99.98%).Bagfiltersandstringwoundfiltercartridgestypicallyhave only 90% filtration efficiency. This means that for each 100,000 particles reaching the filter, 10,000 particles pass through it compared to only 20 particles in a filter with an efficiency of 99.98%.

Formoreinformationontheimportanceofproperfiltration,pleaseconsultourpublication“Filtration”(codenumber521B0861),which also will provide you with an explanation of filtration definitions and a guidance on how to select the right filter.

Page 5: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0850 DKCFN.PD.013.FA5.02 5

10. Dimensions10.1 Pump

Description APP0.6 and APP1.0 APP1.5, APP1.8, APP2.2 and APP2.5,

APP3.0 and APP3.5

A Portposition,mm(in) 15.9(0.63) 18.8(0.74) 18.8(0.74)

B Portposition,mm(in) 15.9(0.63) 21.0(0.83) 21.0(0.83)

C mm(in) Ø88(3.5) Ø105(4.1) Ø105(4.1)

D mm(in) 131(5.2) 166(6.5) 166(6.5)

E Parallelkey,DIN6885,mm(in) 5×5×20(0.20×0.20×0.78)

5×5×20(0.20×0.20×0.78)

5×5×20(0.20×0.20×0.78)

F Bleeding M6,HexagonAF=5mm M6,HexagonAF=5mm M6,HexagonAF=5mm

I Inlet connection BSPG½”;15(0.59)deep BSPG¾”;15(0.59)deep BSPG¾”;15(0.59)deep

O Outletconnection BSPG½”;15(0.59)deep BSPG½”;17(0.67)deep BSPG¾”;17(0.67)deep

Pump mounting flange SAEA2 SAEA2 SAEA2

Page 6: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

6 DKCFN.PD.013.FA5.02 521B0850

10.2 Complete unit

Pump A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) H (mm) IEC Electric motor

APP0.6 200 245 90 140 100 265 100 131 1.5kW,FPA90S-2

APP1.0 200 245 90 140 125 290 100 131 2.2kW,FPA90L-2

APP1.5 250 280 100 160 140 325 120 166 3.0kW,FPA100L-2

APP1.8 250 302 112 190 140 340 120 166 4.0kW,FPA112M-2

APP2.2 300 342 132 216 140 390 144 166 5.5kW,FPA132S1-2

APP2.5 300 342 132 216 178 430 144 166 7.5kW,FPA132S2-2

APP3.0 330 420 160 254 210 505 188 166 11kW,FPA160M1-2

APP3.5 330 420 160 254 210 505 188 166 11kW,FPA160M1-2

11. Installation11.1 MountingThefigurebelowillustrateshowtomountthepumpandconnectittoelectricmotor/combustionengine.

A: FlexiblecouplingB: Bell housingC: Motor shaft

Ifalternativemountingisrequired,pleasecontactDanfossSalesOrganizationforfurtherinformation.To ensure easy mounting of the flexible coupling without using tools, the tolerances must be dimensioned accordingly.

Note: Any axial and/or radial loads on the shaft must be avoided, see “User guide” (521B0888).

A CB

Min. 5 mm

The pump should be connected to the rest of the plant with a flexible hoses.

Page 7: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0850 DKCFN.PD.013.FA5.02 7

11.2 Open-ended systems with water supply from tankInordertoeliminatetheriskofcavitation,apositiveinletpressureshouldalwaysbemaintainedbyobservingthefollowingguidelines:1. Placethetank(1)abovepumpinlet(waterlevelintankshouldalwaysbeabovethepump).2. Placeafilter(2)inthewatersupplylineinfrontofthetank.3. Dimensiontheinletline(3)withminimumpressuredrop(largeinternaldiameter,minimumlengthofpipe,avoidbendsand

fittingswithsmallinternaldiameter).

11.3 Open-ended system with direct water supplyInordertoeliminatetheriskofcavitation,apositiveinletpressureisalwaystobemaintainedatmin.0.5bar(7 3psi)andmax.5bar(72.5psi).1. Placethefilter(1)inthewatersupplylineinfrontofthepump.2. Placeamonitoringpressureswitch(2)setatmin.1bar(14.5psi)betweenfilterandpumpinlet.Themonitoringswitchmust

stopthepumpatpressureslowerthan1bar.(14 5psi)Atspeedsabove3000rpm-use2bar(29psi)assetpoint.

11.4 RO system with APP pump1. Foreasysystembleedingandflushing,applyabypassnon-returnvalve(1)inparallelwiththeAPPpump.Thevalveis

integrated in APP3.0 and APP3 5.2. Placeaninletfilter(2)infrontoftheAPPpump(3).Pleaseconsultsection9,“Filtration”forguidanceonhowtoselectthe

right filter. Throughly clean pipes and flush system prior to start-up.3. Placeamonitoringpressureswitch(6)setatmin.1barbetweenfilterandpumpinlet.Themonitoringswitchmuststopthe

pump at pressures lower than1bar(14.5psi).At3000rpm-use2bar(29psi)assetpoint.4. Dimensiontheinletlinetoobtainminimumpressureloss(largeflow,minimumpipelength,minimumnumberofbends/

connections,andfittingswithsmallpressurelosses).5. Inordertoeliminatetheriskofdamageandcavitation,apositivepressureattheinlet(4)isalwaystobemaintainedatmin.

0.5bar(7.3psi)andmax.5bar(72.5psi). At speeds above 3000 rpm the pressure at the inlet of the water pump must be min. 2bar(29psi).

6. Useflexiblehoses(5)tominimizevibrationsandnoise.7. Installasafetyvalve(7)inordertoavoidsystemdamageastheDanfossAPPpumpcreatespressureandflowimmediately

after start-up, regardless of any counter-pressure.

M

Brine

PermeateAPPFeed

2

5

3

1

5 4

7

6

Page 8: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

8 DKCFN.PD.013.FA5.02 521B0850

12. ServiceProvidedthatthepumphasbeenrunningaccordingtotheDanfossspecificationsonpre-filtration,pressure,androtationspeed,Danfossguaranteesminimum8000hoursoperation,howevermax.18monthsfromdateofsale.

Topreventatotalanddisastrousbreakdown,Danfossrecommendsapumpinspectionaftermax.8000hours–atwhichanywornparts must be replaced.

Note: It is always recommended to replace pistons and shaft sealing if another service-free period is to be obtained.

If the pistons are not replaced, more frequent inspection is recommended.

TheAPPpumpismadeofduplex/superduplexmaterialswithfinecorrosionproperties.However,it is always recommended to flush the pump when the system is shut down.

TheshaftsealingintheAPPpumpismadeofAISI316.AthighTDSandhighwatertemperature,theservicelifeoftheshaftsealingwillbereduced.Fortheseapplicationsitisrecommendedtoreplacetheshaftsealingafterapprox.4000hoursoperation.

12.1 Periodic maintenanceWateractsaslubricantintheAPP.Thusthereisnooilinthepump.

ByoperationbelowthecurveforSAF2507inthefigureinsection7.1,nopartsareexpectedtobereplacedwithinthefirst8000hours of operation.

12.2 RepairIncaseofirregularfunctionoftheAPP,pleasecontacttheDanfossROSolutionsSalesOrganisation.

Page 9: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0851 DKCFN.PD.013.FB3.02 01-2008

DATA SHEETWater PumpsAPP5.1 - 10.2

1. General information

APP5.1, APP6.5, APP7.2, APP8.2 and APP10.2 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater reverse osmosis filtration applications and for high pressure salt water pumping.

The APP pumps are based on the axial piston principle enabling a very light and compact design, and they are designed so that lubrication of the moving parts in the pumps is provided by the fluid itself. No oil lubrication is thus required.

All parts included in the APP pumps are designed to provide long service life, i.e. long service life with a constantly high efficiency and minimum of service required.

The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement, regardless of any counter-pressure.

2. Benefits• Oneofthesmallestandlightestpumpsonthemarket.• Can be powered by a combustion engine provided that a special coupling is used.• Generatesinsignificantpulsationsinthepressureline.• Nopreventivemaintenancerequired(noperiodicservicelikee.g.changeoflubricantandwearingparts).• Longservicelife.Danfossguarantees8000hoursmaintenance-freeoperation.• Allpartsofthepumparemadeofnon-corrosivematerialseg.duplex(SAF2205/EN1.4462)and superduplex(SAF2507/EN1.4410)stainlesssteelandcarbonreinforcedPEEK.• Highefficiency.

1: Shaftsealing 2: Mounting flange 3: Bleeding plugs4: Retainingring5: Piston/shoe 6: Valve plate7: Swashplate 8: Cylinder barrel9: Spring10: Port plate11: Connecting flange12: Housingwithbearing

1 2 3 4 5

8 9 10

6

11127

Page 10: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

2 DKCFN.PD.013.FB3.02 521B0851

3. Technical dataCode number 180B3005 180B3006 180B3007 180B3008 180B3010

APP pumps APP5.1 APP6.5 APP7.2 APP8.2 APP10.2

Geometricdisplacement cm3/rpm(in3/rpm) 50 (3.05) 63 (3.84) 70 (4.27) 80 (4.88) 100 (6.10)

Flow(1800rpm) 1) m3/h(gpm) 5.0 (22.0) 6.4 (28.2) 7.2 (31.7) 8.2 (36.1) 10.2 (44.9)

Min. pressure 2) bar(psi) 20 (290) 20 (290) 20 (290) 20 (290) 20 (290)

Max. pressure, cont. 3) bar(psi) 80 (1160) 80 (1160) 80 (1160) 80 (1160) 80 (1160)

Max. pressure, intermittent4) bar(psi) 100 (1450) 100 (1450) 100 (1450) 100 (1450) 100 (1450)

Max. speed cont. 5) rpm 1800 1800 1800 1800 1800

Min. speed cont. rpm 700 700 700 700 700

Power requirement at 80 bar and 1800 rpm:

kW(hp) 13.7 (18.4) 17.3 (23.2) 19.2 (25.7) 21.7 (29.1) 27.4 (36.7)

Weight kg(lb) 30 (66) 30 (66) 30 (66) 30 (66) 30 (66)

1) Typicalaverageflowat80bar.2) Forlowerpressure,pleasecontactDanfossROSolutionsSalesOrganization. 3) Forhigherpressure,pleasecontactDanfossROSolutionsSalesOrganzation. 4) Intermittent pressure is acceptable for less than 10 seconds per minute.5) Forspeedsabove1500 rpm the APP pump must be boosted at a pressure of 2-5 bar (29-72 5psi).

4. Flow at different rpmUsing the diagram shown below, it is easy to select the APP pump which fits the application best if the flow required and the rotationspeed(rpm)ofthepumpareknown.

0,00

2,00

4,00

6,00

8,00

10,00

12,00

600 800 1000 1200 1400 1600 1800 2000

rpm

m3 /h

Furthermore,thisdiagramshowsthattheflowcanbechangedbychangingtherotationspeedofthepump.Theflow/rpmratioisconstant, and the “desired “ flow can be obtained by changing the rotation speed to a corresponding value. Thus, the required rpm can be determined as: Desiredflow×Ratedrpm Requiredrpm= Ratedflow

5. Power requirements

Pump model Flow Pressure rpm Calc. factor

60 bar 70 bar 80 bar

l/min m3/h gpm 870 psi 1015 psi 1160 psi

APP5.1 66 4.0 17.4 8.3kW 9.7kW 11.1kW 1460 475.2

APP5.1 79 4.7 20.9 10.0kW 11.7kW 13.4kW 1752 475.2

APP6.5 83 5.0 22.0 10.5kW 12.3kW 14.0kW 1460 475.2

APP6.5 100 6.0 26.4 12.6kW 14.7kW 16.8kW 1752 475.2

APP7.2 93 5.6 24.6 11.6kW 13.5kW 15.5kW 1470 480.6

APP7.2 112 6.7 29.5 13.9kW 16.3kW 18.6kW 1764 480.6

APP8.2 106 6.4 28.1 12.7kW 14.8kW 16.9kW 1470 502.2

APP8.2 128 7.7 33.7 15.3kW 17.8kW 20.3kW 1764 502.2

APP10.2 133 8.0 35.1 16.0kW 18.7kW 21.4kW 1470 496.2

APP10.2 159 9.6 42.1 19.3kW 22.5kW 25.7kW 1764 496.2

The power requirements can be determined using one of the following guiding equations:

l/min×bar 16.7×m3/h×bar 0.26×gpm×psiRequiredpower= [kW]or [kW]or [kW] Calc. factor Calc. factor Calc. factor

1hp = 0.75kW1kW = 1.34hp1gpm= 3.79l/min1l/min= 0.26gpm1 m3/h= 4.40gpm1gpm= 0.23m3/h

APP8.2

APP6.5

APP5.1

APP10.2

APP7.2

Page 11: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0851 DKCFN.PD.013.FB3.02 3

6. Inlet pressureWatersupplytotheAPPpumpiseithermadefromatankplacedabovethepumpordirectlyfromafeedpump.Thepressureatthepumpinlet(I)mustbeintherange:0.5-5bar(7 3-72.5psi).

7. Temperature and corrosion7.1 Operation: • Fluidtemperature: +3°Cto+50°C(+37.4°Fto122°F)-dependentontheNaClconcentration• Ambienttemperature: +3°Cto+50°C(+37.4°Fto122°F)

The chart below illustrates the corrosive resistance of different types of stainless steel related to NaCl concentration and temperature. AllcriticalpartsoftheAPPpumparemadeofSAF2507.IftheAPPpumpisoperatedathighsalinity,alwaysflushthepumpwithfreshwateratoperationstopinordertominimisetheriskof crevice corrosion.

NaCl vs. temperature

7.2 Storage: • Storagetemperature: -40°Cto+70°C(+37.4°Fto122°F)–providedthattheAPPpumpisdrainedoffluidandstored

”plugged”.

Antefreezeprotectionisrequiredattemperaturesbelow2°C.DanfossrecommendsusingDowcalNfromDowChemicalCompany or Chillsafe mono propylene glycol from Arco Chemical Company.

8. Noise levelThechartindicatesthenoiselevelindB(A)measuredatadistanceof1mfromtheAPPpumpinareverberation room.

Type 60 bar (580 psi)1500 rpm

60 bar (580 psi)1800 rpm

80 bar (2000 psi)1500 rpm

80 bar (2000 psi)1800 rpm

APP5.1 74 79 73 78

APP6.5 74 79 73 78

APP7.2 74 79 73 78

APP8.2 74 79 73 78

APP10.2 74 79 73 78

Generally,noisewillbereducedifspeedisreducedandviceversa.Useflexiblehosesinordertominimizevibrationsandnoise.

SincetheAPPpumpistypicallymountedonabellhousingorframe,thenoiselevelcanonlybedeterminedforthecompleteunit(system).

ItisthereforeveryimportantthattheAPPpumpismountedcorrectlyonaframewithvibrationabsorbertominimizevibrationsandnoise.

The noise level is influenced by:•Thespeedofthepump,highrpmcreatemorenoisethanlowrpm•Rigidmountingofthepumpgeneratesmorenoisethanflexiblemounting•Pipemountingdirecttothepumpincreasesthenoiselevelcomparedtoaflexiblehose 9. FiltrationAswaterhasverylowviscosity,theAPPpumpshavebeendesignedwithverynarrowclearanceinordertocontrolinternalleakageratesandimprovecomponentperformance.Thereforeitisimportantthattheinletwaterisfilteredproperlytominimizethewearofthe pump.

Themainfiltermusthaveafiltrationefficiencyof99.98%at10µm.Werecommendthatyouuseprecisiondepthfiltercartridgesrated10µmabs.ß10>5000(equivalenttoafiltrationefficiencyof99.98%).Bagfiltersandstringwoundfiltercartridgestypicallyhave only 90% filtration efficiency. This means that for each 100,000 particles reaching the filter, 10,000 particles pass through it compared to only 20 particles in a filter with an efficiency of 99.98%.

Formoreinformationontheimportanceofproperfiltration,pleaseconsultourpublication“Filtration”(codenumber521B0861),

904L / SAF 2205

Page 12: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

4 DKCFN.PD.013.FB3.02 521B0851

which also will provide you with an explanation of filtration definitions and a guidance on how to select the right filter.

10. Dimensions10.1 APP pump

Description APP5.1 and APP10.2

C Bleeding M6,HexagonAF=5mm

D Parallelkey,DIN6885,mm(in) 10×8×45(0.39×0.31×1.77)

I Inlet connection M42x1½mm;13mm(0.51in)deep

O Outletconnection M42x1½mm;13mm(0.51in)deep

Pump mounting flange 125 A2

10.2 Complete unit

Pump A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) IEC Electric motor

APP5.1 350 415 160 254 210 505 11kW,FPC160M-4

APP6.5 350 415 160 254 254 560 15kW,FPC160L-4

APP7.2 350 415 160 254 254 560 15kW,FPC160L-4

APP8.2 350 460 180 279 241 590 18.5kW,FPC180M-4

APP10.2 350 460 180 279 279 630 22kW,FPC180L-4

APP10.2 400 505 200 318 305 660 30kW,FPC200L-4

Forinletandoutletconnectionsdata,see“Accessoriescatalogue”(521B0903).

Page 13: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0851 DKCFN.PD.013.FB3.02 5

11. Installation11.1 MountingThefigurebelowillustrateshowtomounttheAPPpumpandconnectittoanelectricmotor/combustionengine.

A: FlexiblecouplingB: Bell housingC: Motor shaft

Ifalternativemountingisrequired,pleasecontactDanfossSalesOrganizationforfurtherinformation.To ensure easy mounting of the flexible coupling without using tools, the tolerances must be dimensioned accordingly.

Note: Any axial and/or radial loads on the shaft must be avoided, see “User guide” (521B0888).

The APP pump should be connected to the rest of the plant with a flexible hoses.

11.2 Open-ended systems with water supply from tankInordertoeliminatetheriskofcavitation,apositiveinletpressureshouldalwaysbemaintainedbyobservingthefollowingguidelines:1. Placethetank(1)abovetheAPPpumpinlet(waterlevelintankshouldalwaysbeabovethepump).2. Placeafilter(2)inthewatersupplylineinfrontofthetank.3. Dimensiontheinletline(3)withminimumpressuredrop(largeinternaldiameter,minimumlengthofpipe,avoidbendsand

fittingswithsmallinternaldiameter).

11.3 Open-ended system with direct water supplyInordertoeliminatetheriskofcavitation,apositiveinletpressureisalwaystobemaintainedatmin.0.5bar(7 3psi)andmax.5bar(72.5psi).1. Placethefilter(1)inthewatersupplylineinfrontoftheAPPpump.2. Placeamonitoringpressureswitch(2)setatmin.1bar(14.5psi)betweenfilterandpumpinlet.Themonitoringswitchmust

stopthepumpatpressureslowerthan1bar(14.5psi)Atspeedsabove1500rpm-use2bar(29psi)assetpoint.

A CB

Min. 3 mm

Page 14: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

6 DKCFN.PD.013.FB3.02 521B0851

11.4 RO system with APP pump1. Foreasysystembleedingandflushing,applyabypassnon-returnvalve(1)inparallelwiththeAPPpump.2. Placeaninletfilter(2)infrontoftheAPPpump(3).Pleaseconsultsection9,“Filtration”forguidanceonhowtoselectthe

right filter. Throughly clean pipes and flush system prior to start-up.3. Placeamonitoringpressureswitch(6)setatmin.1barbetweenfilterandpumpinlet.Themonitoringswitchmuststopthe

pump at pressures lower than1bar(14.5psi).Above1500rpm-use2bar(29psi)assetpoint.4. Dimensiontheinletlinetoobtainminimumpressureloss(largeflow,minimumpipelength,minimumnumberofbends/

connections,andfittingswithsmallpressurelosses).5. Inordertoeliminatetheriskofdamageandcavitation,apositivepressureattheinlet(4)isalwaystobemaintainedatmin.

0.5bar(7.3psi)andmax.5bar(72.5psi). At speeds above 1500 rpm the pressure at the inlet of the APP pump must be min. 2bar(29psi).

6. Useflexiblehoses(5)tominimizevibrationsandnoise.7. Installasafetyvalve(7)inordertoavoidsystemdamageastheAPPpumpcreatespressureandflowimmediatelyafterstart-

up, regardless of any counter-pressure.

M

Brine

PermeateAPPFeed

12. ServiceProvidedthattheAPPpumphasbeenrunningaccordingtotheDanfossspecificationsonpre-filtration,pressure,androtationspeed,Danfossguaranteesminimum8000hoursoperation,howevermax.18monthsfromdateofsale.

Topreventatotalanddisastrousbreakdown,Danfossrecommendsapumpinspectionaftermax.8000hours–atwhichanywornparts must be replaced.

Note: It is always recommended to replace pistons and shaft sealing if another service-free period is to be obtained.

If the pistons are not replaced, more frequent inspection is recommended.

TheAPPpumpismadeofduplex/superduplexmaterialswithfinecorrosionproperties.However,it is always recommended to flush the APP pump when the system is shut down.

TheshaftsealingintheAPPpumpismadeofHasteloyC.AthighTDSandhighwatertemperature,theservicelifeoftheshaftsealingwillbereduced.Fortheseapplicationsitisrecommendedtoreplacetheshaftsealingafterapprox.4000hoursoperation.

12.1 Periodic maintenanceWateractsaslubricantintheAPPpump.Thusthereisnooilinthepump.

ByoperationbelowthecurveforSAF2507inthefigureinsection7.1,nopartsareexpectedtobereplacedwithinthefirst8000hours of operation.

12.2 RepairIncaseofirregularfunctionoftheAPPpump,pleasecontacttheDanfossROSolutionsSalesOrganisation.

2

5

6

3

1

5 4

7

Page 15: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0852 DKCFN.PD.013.FC3.02 08-2008

DATA SHEETWater Pumps

APP21-30

1. General information

APP21-30 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater reverse osmosis filtration applications and for high pressure salt water pumping.

The pumps are based on the axial piston principle enabling a very light and compact design, and they are designed so that the lubrication of the moving parts in the pumps is provided by the fluid itself. No oil lubrication is thus required.

The pump has an integrated flushing valve that allows the salt water to flow from inlet to the outlet, when the pump is not running.

All parts included in the pumps are designed to provide long service life, i.e. long service life with a constantly high efficiency and minimum service required.

The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement.

2. Benefits• Oneofthesmallestandlightestpumpsonthemarket.• Can be powered by a combustion engine provided that a special coupling is used.• Longservicelife/Nopreventivemaintenancerequiredinthewarrantyperiod.• Generatesinsignificantpulsationsinthepressureline.• Nooillubricant.• Integratedflushingvalve• Allpartsofthepumparemadeofnon-corrosivematerialseg.Duplex(SAF2205/EN1.4462/UNSS31803-S32205)and Super-duplex(SAF2507/EN1.4410/UNSS32750)stainlesssteelandcarbonreinforcedPEEK• Highefficiency

1: Shaftsealing 2: Mounting and port flange 3: Bleeding plugs4: Retainingring5: Piston/shoe6: Valve/thrustplate7: Swashplate8: Cylinderbarrel9: Springs10: Port plate11: Flushingvalve12: Housingwithbearing13: Bolts for bell housing14: Drainplug

Page 16: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

2 DKCFN.PD.013.FC3.02 521B0852

3. Technical dataCode number 180B3051 180B3054 180B3056 180B3060

APP pumps APP21 APP24 APP26 APP30

Geometricdisplacement cm3/rpm(in3/rpm) 308 (18,8) 362 (22,1) 389 (23,7) 444,0(27,1)

Flow(1200rpm)at60bar m3/h(gpm) 20,8 (91,5) 24,77 (108,7) 26,6 (117,1) 30,7(135,1)

Min. outlet pressure bar(psi) 40 (580) 40 (580) 40 (580) 40,0(580)

Max. outlet pressure bar(psi) 80 (1160) 80 (1160) 80 (1160) 80,0(1160)

Min. inlet pressure cont. 2(29) 2(29) 2(29) 3(44)

Max inlet pressure cont. bar(psi) 6(87) 6(87) 6(87) 6(87)

Maxinletpressurepeak bar(psi) 10(145) 10(145) 10(145) 10(145)

Maximum speed rpm 1200 1200 1200 1200

Minimum speed rpm 700 700 700 700

Power requirement at max.speedand80bar(1160psi):

kW(hp) 55 (73,7) 65 (87,1) 70 (93,8) 81(108,6)

Torque Nm(lbf-ft) 436 (321) 512 (377) 550 (405) 642(473)

Weight kg(lb) 105 (231,5) 105 (231,5) 105 (231,5) 105(231,5)

FlushingvalveKvvalue(∆p=1bar) m3/h(gpm) 14,4 (63,4) 14,4 (63,4) 14,4 (63,4) 14,4(63,4)

4. Flow at different rpmWhenusingthediagramshownbelow,itiseasytoselectthepumpwhichfitstheapplicationbestiftheflowrequiredandtherotationspeed(rpm)ofthepumpareknown.

Furthermore,thisdiagramshowsthattheflowcanbechangedbychangingtherotationspeedofthepump.Theflow/rpmratioisconstant, and the “desired “ flow can be obtained by changing the rotation speed to a corresponding value. Thus, the required rpm can be determined as:

Desiredflow×1200rpmRequiredrpm= Ratedflow

APP 21

APP 24

APP 26

APP 30

10

15

20

25

30

35

700 800 900 1000 1100 1200

rpm

m³/h

Page 17: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0852 DKCFN.PD.013.FC3.02 3

5. Temperature and corrosion5.1 Operation: • Fluidtemperature: +3°Cto+40°C(+37.4°Fto+104°F)-dependentontheNaClconcentration• Ambienttemperature: +3°Cto+50°C(+37.4°Fto+122°F)

The chart below illustrates the corrosive resistance of different types of stainless steel related to NaCl concentration and temperature. TheAPPwaterpumpismadeofSAF2507andSAF2205.IfthewaterpumpisoperatedabovetheSAF2507line,alwaysflushthethewaterpumpwithfreshwateratoperationstopinordertominimisetheriskofcrevicecorrosion.

NaCl vs. temperature

5.2 Storage: • Storagetemperature:-40°Cto+70°C(-40°Fto158°F)–providedthatthepumpisdrainedoffluidandstored”plugged”.

• Antifreezeprotectionisrequiredattemperaturesbelow2°C.DanfossrecommendsusingDowcalNfromDowChemicalCompany or Chillsafe mono propylene glycol from Arco Chemical Company.

6. Noise levelThenoisefromtheAPP21-30istypically84dB(A)at60bar/1200rpm.

Generally,noisewillbereducedifspeedisreducedandviceversa.Useflexiblehosesinordertominimizevibrationsandnoise.

Sincethepumptypicallyismountedonabellhousingorframe,thenoiselevelcanonlybedeterminedforthecompleteunit(system).

Itisthereforeveryimportantthatthepumpismountedcorrectlyonaframewithvibrationabsorbertominimizevibrationsandnoise.

The noise level is influenced by:•Thespeedofthepump,highrpmcreatemorenoisethanlowrpm•Rigidmountingofthepumpgeneratesmorenoisethanflexiblemounting•Pipemountingdirecttothepumpincreasesthenoiselevelcomparedtoaflexiblehose

7. FiltrationAswaterhasverylowviscosity,theAPPpumpshavebeendesignedwithverynarrowclearanceinordertocontrolinternalleakageratesandimprovecomponentperformance.Thereforeitisimportantthattheinletwaterisfilteredproperlytominimizethewearofthe pump.

Themainfiltermusthaveafiltrationefficiencyof99.98%at10µm.Werecommendthatyouuseprecisiondepthfiltercartridgesrated10µmabs.ß10>5000(equivalenttoafiltrationefficiencyof99.98%).Bagfiltersandstringwoundfiltercartridgestypicallyhaveonly90%filtrationefficiency.Thismeansthatforeach100,000particlesreachingthefilter,10,000particlespassthroughitcomparedtoonly20particlesinafilterwithanefficiencyof99.98%.

Formoreinformationontheimportanceofproperfiltration,pleaseconsultourpublication“Filtration”(codenumber521B0861),which also will provide you with an explanation of filtration definitions and a guidance on how to select the right filter.

904L / SAF 2205

Page 18: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

4 DKCFN.PD.013.FC3.02 521B0852

8. Dimensions

Description APP21 - APP30 Accessories Type Code number

E Parallelkey,DIN6885,mm(in) 12×8×70(0.47×0.31×2.76)

3”inlethosekit2m/79”

3”Victaulic

180Z0277

F Bleeding G¼”,HexagonAF=8mm Non-returnvalve(outlet) 2½”Victaulic(OD73.1mm) 180H0050

I Inletport M60x1.5;depth24mm

O Outletport M60x1.5;depth24mm

Pump mounting flange 180B4

Formoredetailsontheaccessories,pleaseconsultourpublication“Hosesandhosefittings”(codenumber521B0909).

9. Dimensions, complete unit

Accessories

Accessories

APP21-26:351(13,82)

APP30:357(14,05)

APP30:357mmAPP21-26:351mm

IEC315:295mmIEC250-280:265mm

APP 30: 310mmAPP21-26:304mm

D

F

E

Page 19: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

521B0852 DKCFN.PD.013.FC3.02 5

Pump A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) IEC Electric motor

APP21-24 550 635 250 406 349 770 55kW,IEC250M-4

APP24-26 550 693 280 457 368 845 75kW,IEC280S-4

APP26-30 550 693 280 457 419 895 90kW,IEC280M-4

APP30 660 810 315 508 406 990 110kW,IEC315M-4

Note: Code numbers 180B3051, 180B3054, 180B3056 and 180B3060 do not include electric motor, bell housing and fittings.

10. Installation10.1 MountingThefigurebelowillustrateshowtomountthepumpandconnectittotheelectricmotor/combustionengine.

A: FlexiblecouplingB: Bell housingC: Motor shaft

Ifalternativemountingisrequired,pleasecontactDanfossROSalesOrganizationforfurtherinformation.To ensure easy mounting of the flexible coupling without using tools, the tolerances must be dimensioned accordingly.

Note: Any axial and radial loads on the pump shaft must be avoided.

A CB

10.2 Open-ended system with direct water supplyInordertoeliminatetheriskofcavitation,apositiveinletpressureisalwaystobemaintainedatmin.2bar(29psi)forAPP21-26,3bar(44psi)forAPP30andmax.6bar(72.5psi).1. Placethefilter(1)inthewatersupplylineinfrontofthepump.2. Placeamonitoringpressureswitch(2)setatmin.inletpressurebetweenfilterandpumpinlet.Themonitoringswitchmust

stop the pump at pressures lower than min. inlet pressure.3. Installasafetyvalve(3)inordertoavoidsystemorpumpdamageincasethepumpstopsmomentarilly.

3

Page 20: Danfoss, Asco Suppliers M & M Controls, Solenoid Valves, Transmitters, Danfoss …mandmcontrols.co.uk/.../Danfoss_Nessie_APP_Pumps.pdf · 2011-01-10 · Created Date: 6/22/2009 9:38:23

6 DKCFN.PD.013.FC3.02 521B0852

10.3 RO system with APP pump1. Foreasysystembleedingandflushing,abypassnon-returnvalve(1)isintegratedintheAPPpump.2. Placeinletfilter(2)infrontoftheAPPpump(3).Pleaseconsultsection7,“Filtration”forguidanceonhowtoselecttheright

filter. Throughly clean pipes and flush system prior to start-up.3. Placeamonitoringpressureswitch(6)setatmin.inletpressurebetweenfilterandpumpinlet.Themonitoringswitchmust

stop the pump at pressures lower than min. inlet pressure.4. Dimensiontheinletlinetoobtainminimumpressureloss(largeflow,minimumpipelength,minimumnumberofbends/

connections,andfittingswithsmallpressurelosses).5. Inordertoeliminatetheriskofdamageandcavitation,apositivepressureattheinlet(4)isalwaystobemaintainedatmin.

inletpressureandmax.inletpressure.Recommendtoinstallsafetyvalve(7)inordertoavoidhighpressurepeaks.6. Installanon-returnvalve(8)inoutletinordertoavoidbackspinofthepump.Thevolumeofwaterinthemembranevessel

worksasanaccumulatorandwillsendflowbackwardsincasethepumpstopsmomentarilly.7. Useflexiblehoses(5)tominimizevibrationsandnoise.8. Installasafetyvalve(9)inordertoavoidsystemdamageastheDanfossAPPpumpcreatespressureandflowimmediately

after start-up, regardless of any counter-pressure.

11. Service and warrantyDanfossAPPpumpsaredesignedforlongoperation,lowmaintenanceandreducedlifecyclecosts.

ProvidedthatthepumphasbeenrunningaccordingtotheDanfossspecifications,Danfossguarantees8.000hoursservice-freeoperation,however,max18monthsfromdateofproduction.

IfDanfossrecommendationsconcerningsystem-designarenot followed, it will strongly influence the life of the APP pumps.

Maintenance:After8.000hoursofoperationit is strongly recommended to inspect the pump and change any worn parts, e.g. pistons and shaft seal.Thisisdoneinordertopreventapotentialbreakdownofthepump.

Ifthepartsarenotreplaced,morefrequentinspectionisrecommendedaccordingtoourguidelines.

Standstill:TheAPPpumpsaremadeofduplex/superduplexmaterialswithexcellentcorrosionproperties.It is however, always recommended to flush the pump with freshwater when the system is shut down.

11.2 RepairIncaseofirregularfunctionoftheAPP,pleasecontacttheDanfossROSolutionsSalesOrganisation.

Media filter M

Brine

PermeateFeed

1

223

4

5

67 9

85