32
Top comfort Heating, hot water and cooling Low CO 2 emissions Modular system DAIKIN ALTHERMA FLEX TYPE www.daikinaltherma.eu Residential and Commercial applications

DAKIKIN VRV - ECPEN12-727_Daikin Altherma Flex Type-tcm478-216220

Embed Size (px)

DESCRIPTION

DAIKIN

Citation preview

  • Topcomfort

    Heating,hotwaterandcooling

    LowCO2emissions

    Modularsystem

    Daikin altherma Flex type

    www. d a i k i n a l t h e rm a . e u

    Res ident i a l and Commerc i a l app l i ca t ions

  • 2Daikin altherma Flex type: a centraliseD heating, hot water anD cooling system For resiDential anD commercial applications

  • 3Forthelast50years,wehavebeentheleading innovatoRinthe

    heatpump industry.Becauseof thisconstant focuson innovation,

    we were the first to deliver total Climate ContRol that

    RespeCts the enviRonment, ishighlyeneRgy effiCient and

    Cost effeCtive.

    TheDaikinAlthermaFlexTyperangeisthedirectresultofthoseyears

    ofresearch,innovationandcontinuousqualityimprovement.Alwaysat

    theleadingedgeofclimatecontrol,wespendourtimelisteningtowhat

    ourcustomerswantandthendeliveringtomorrowstechnologytoday.

    TheDaikinAlthermaFlexTyperangeisamixofintelligentsolutionsand

    advancedcontroltechnologiesthatprovidestheultimateincontrollable

    comfortforresidentialandcommercialbuildingswhilerespectingthe

    environmentthroughreducedenergyconsumption.

    Astheproviderofchoiceforthosewhoonlywantthebestinclimate

    control, weContinuously innovate so that otheRs need

    to follow ouR lead.

    2 >17

    18 >40

  • Introduction 5

    Efficientclimatecontrolforapartmentbuildings 6

    TwoDaikintechnologiescombined 8

    Daikinheatpumpconvector 10

    Morebenefitsofadvanceddesign 11

    DaikinAlthermaFlexType:atypicalinstallation 12

    DaikinAlthermaFlexType:theflexibleheatingsolution 14

    Specifications 30

    duRable & effiCient eneRgy solutions foR resiDential appliCation

    4

  • Providingtotalclimatecontrolinanapartmentbuildingorincollective

    housing presents a particular challenge because a large number of

    roomssimultaneouslyneedheatingorcooling.

    DaikinAlthermaFlexTypeisdesignedwiththischallengeinmind.Each

    outdoorunitcanbelinkedtouptotenindoorunits,witheachindoor

    unitbeingindividuallycontrolled,tomakesuretheperfecttemperature

    ismaintainedatalltimes. Inaddition,bymakingoptimaluseofVRV,

    cascadetechnologyandheatpumptechnologies,thesystemefficiently

    generateshotwaterinbothheatingandcoolingmodes.

    heating hot wateR Cooling

    only one system

    5

  • 6EnergyefficientheatpumptechnolgyDaikin Altherma Flex Type is todays answer to current andfutureissuesofincreasingenergycostsandunacceptablehighenvironmental impact associated with conventional heatingsystems.WithDaikinAlthermaFlexType,2/3ofthegeneratedheatcomes from theair,which is recognisedasa renewableenergysourcethatisfreeofcharge!DaikinAlthermaFlexTypeachievesatypicalseasonalCOPof3inthemoderateWesternandcentralEuropeanclimate.Compared toanoilboiler, thisresultsin:Upto36%lessrunningcosts*Upto71%reductionofCO2emissions*

    Upto35%reductioninprimaryenergyuse*

    *DatacalculatedtakinginaccountBelgianconditions:SeasonalCOPof3,averageenergyprices2007-2010,CO2emissionfactorforelectricityproduction

    effiCient Climate ContRol

    foR apaRtment buildings and ColleCtive housing

    ModularsystemOne ormore inverter-controlled outdoor heat pump units canprovideheating,coolingandhotwater.Outdoorunitsbetween23and45kWextracttheheatfromtheoutdoorair,raiseittoanintermediate temperature and transfer this heat energy to theindividualindoorunits.

    Indoorunitsareavailableinseveralclasses(6,9,11,14and16kW),ensuringoptimumefficiency.Oneoutdoorunitcanbecombinedwithuptotenindoorunits.Multipleoutdoorunitscanbeinstalledforlargerapplications.

    3-in-1systemDaikinAlthermaFlexTypeheats,coolsandproducesdomestichotwater: Heating:leavingwatertemperaturesupto80C Cooling:leavingwatertemperaturesdownto5C Hotwater:tanktemperaturesupto75CThanks to the heat recovery function, the system can heat upthe hotwater tank up to 60Cwith rejectedheat from coolingoperation.

    100% 82% 68% 120% 92% 89% 100% 73% 29%PrimaryenergyEfficiency CO2emissionsRunningcost

    Condensing gas

    daikin altherma flex type

    fuel

  • 7outdoor

    Oneormoreindoorandoutdoorunits

    1

    2

    3

    Modularsystem 1APARTMEnT TOTALBUILDIng

    Oneormoreoutdoorunits+severalindoorunits>> amodularsystem

    5kW 20kW

    22kW

    40kW

    45kW

    8kW

    Installseparateoutdoorunitstoreachhighercapacities(Separatesystems:theoutdoorunitsarenotconnectedtoeachother)

    note:Heatingcapacities7Cambienttemperature,Coolingcapacities35Cambienttemperature3P,400V1P,230V

    Outdoorunit IndoorinstallationDomestichotwatertank

    = +

    Heating/Cooling

    Indoorunit

    6kW 9kW 11kW 14kW 16kW

    ConCept desCRiption

    Hotwater1

    2Heating

    3Cooling

  • 8SpaceheatingDaikinAlthermaFlexTypeusestworefrigerantcycles,R-410AandR-134a,toheatthewatercircuit.Thepurposeofacascadesystemistoattainorworkwithpressuresandtemperatureswhichcannotbereachedbyusingonlyonerefrigerantcycle.Theaimistogetthebestcharacteristicsoutofthetwoactivecycles.Ther-410arefrigerantcircuithasexcellentcharacteristicswithrespecttolowevaporatingtemperatures,whilether-134acircuithasexcellentcharacteristics for high condensing temperatures. With thecascadetechnology,both refrigerantsareoperatingunder theiroptimalconditions.

    the advantages of cascade technology versus single refrigerant cycle heat pumps: Widewatertemperaturerange(25C80C):alltypesofheat

    emitterscanbeconnected(underfloorheating,fancoilunits,radiators). Existing radiators can also be connected to theDaikinAlthermaFlexTypesystem.

    nodropofefficiencywithincreasingwatertemperatures. Highcapacitiesatlowambienttemperatures. noelectricalheaterrequired.

    HotwaterheatingThankstothecascadetechnology,DaikinAlthermaFlexTypecanreachwatertemperaturesof75Ctoheatupthehotwatertank.Thismakesitahighlyefficientsystemfortheproductionofhotwater.

    Hotwatercanbeproducedupto75C,withouttheassistanceofanelectricheater

    noelectricheaterrequiredforLegionelladisinfection SeasonalCOPof3.0forheatingfrom15Cto60C Heat-uptimefrom15to60Cin70minutes(200Ltank) Equivalent hot water volume of 320L at 40C (without

    reheat)fora200Ltankatatanktemperatureof60C.Highervolumesofequivalenthotwaterareavailablewiththe260ltank,orbyusingahighertanktemperature.

    CoolingThesecond refrigerant cycleR-134acanbebypassed toofferefficientcooling.TheR-410A refrigerantcycle is reversed,andthecoolwatercircuitcanbeusedtocooltherooms.

    Highcoolingcapacitieswithwater temperaturesdown to5C, in combinationwith Daikin heat pump convector orDaikinfancoilunits

    Under floor cooling is possible, with water temperaturesdownto18C

    Heat from cooling operation can be recovered to heatthehotwatertank

    two daikin teChnologies CombinedindooR unit: daikin altheRma CasCade teChnology

    Outdoor indoor

    1 2 3Step Step Step

    Highperformancein3steps:

    1. Theoutdoorunitextractsheatfromtheambientoutdoorair.ThisheatistransferredtotheindoorunitviatheR-410Arefrigerant.

    2. The indoor unit receives the heat and furtherincreasesthetemperaturewiththeR-134arefrigerant.

    3. TheheatistransferredfromtheR-134arefrigerantcircuittothewatercircuit.Thankstotheuniquecascadecompressor,watertemperaturesof80Ccanbereachedwithoutusinganadditionalbackupheater.

  • 9ModularflexibilityDaikinAlthermaFlexTypemakesuseofDaikinsrenownedVRVtechnology. A combination of Proportional Integral Derivativecontrolled compressors and electronic expansion valves in theoutdoorunitcontinuouslyadjuststhecirculatingrefrigerantvolumeinresponsetoloadvariationsintheconnectedindoorunits.

    The VRV technology allows multiple indoor units to beconnected to a single outdoor unit and the indoor units tooperateindependentlyofeachother,assuringtotalflexibility.Eachapartmentretainscontrolofitsownheating,hotwaterandcooling.

    InvertercompressorsDaikin Altherma owes its remarkable low energy consumptionto a unique combination of highly efficient inverter-controlledDaikin compressorswith a variable operatingpoint.This allowscapacity to be exactlymatched to the actual heating demandof the building.The ability to fully control the heat capacity oftheoutdoor unit alsomeansmaximumcomfort andminimumenergyconsumption.

    outdooR unit: daikin vRv teChnology

    Heating:upto80C

    Cooling*:downto5C

    Hotwaterheating:

    upto75C

    -20Ccooling

    upto

    43C

    discharge

    liquid

    suction

    R-410a

    R-410a

    R-134a

    h2o

    HeatrecoveryHeat absorbedwhile coolingoneapartment, canbe recoveredinsteadofbeingsimplyreleasedintotheair.Thisrecoveredheatcanbeused

    forhotwaterproductioninthesameapartment forspaceheatingandhotwaterproductioninotherapartments

    Withtheheatrecoveryfunction,theavailableenergyismaximallyused,thusreducingelectricitycosts.

    *onlyavailableon6and9kW

    downto

    >

    >

    >

    >

    >

    >

    >

    heating

    >

    ambienttemperature

    ambienttemperature

  • 10

    TheDaikinheatpumpconvectoroperatesat typicalwater temperaturesof45C,which can be efficiently produced thanks to Daikin Altherma FlexType cascadetechnology.

    The heat pump convector is therefore the ideal heat emitter for apartmentapplications,providinghighcomfortlevels: Smalldimensionscomparedtolowtemperature

    radiators:widthisreducedwith2/3 Lowsoundleveldownto19dB(A),idealheatingandcoolingoperation

    forbedrooms High-capacitycoolingwithwatertemperaturesdownto6C

    HEATDEMAnDOn/OFF

    livingroom OFF On OFF OFF

    bathroom OFF OFF/On On OFF

    bedroom OFF OFF/On OFF/On On

    indoor unit off 65C 65C 45C

    balancingvessel pumpradiators

    externalcontrol

    bathroom

    Valvesclosedincoolingmode

    mixingvalve

    45C

    65C

    living room

    ZOnE1:TLw=65C

    ZOnE2:TLw=45C

    bedroom

    600m

    m

    600m

    m

    bedroom 1living room bedroom 2

    Heating/CoolingoperationHeating(45C)/Cooling(6C)

    45C/7C

    Thankstoitswidewatertemperaturerange,alltypeofheatemitterscanbeconnectedtoDaikinAlthermaFlexType.Also,DaikinAlthermaFlexTypeisabletoworkwithmultiplesetpoints,allowingacombinationofdifferentheatemittersoperatingatdifferentwatertemperatures.Thesetpointof the indoorunitwill automaticallybe lowered in functionof theactualdemandof thevariousheatemitters,ensuringoptimumefficiencyatalltimesandunderallconditions.

    the optimal heat emitteR foR apaRtments

    daikin heat pump ConveCtoR:

    heatpumpconvectors

  • 11

    moRe benefits of advanCed design

    MODULARDESIgnThemodulardesignenablesflexibleandeasyinstallation-thisreducesthecostsandmakesmaintenanceeasier.

    SMALLFOOTPRInTTheindoorunitscanbestackedorsetadjacenttoeachother.Thisensurestheunitstofitintoavailablesmallspacessothattheydonotimpingeonthelivingarea.

    SILEnTOPERATIOnAdvancedmaterialsanddesignsallowallthemovingpartstooperateassilentaspossible,thusensuringthattheclimatecontrolsystemisbarelyaudible.

    InDIVIDUALCOnTROLThelatestintegratedcontroltechnologiesallowthetemperatureofeachresidentialspacetobeindividuallyregulatedandmaintained.

    HIgHEnERgy EFFICIEnCygIVESLOW OPERATIngCOSTS

    Thecombinationoftechnologies,andespeciallyheatpumptechnology,meansthatmuchoftheheatingeffectcomesfromtheambientair.Thisreducestheenergyconsumptionandlowerstheoperatingcosts.

  • 12

    Description:Location:Ostend,Belgium

    numberoffloors:8

    Floorareaforoneapartment:115m2

    Constructionyear:2008

    Designconditioninwinter:-8C

    Heatemitters:Daikinheatpumpconvectors

    Outdoorunit:EMRQ16Ay1

    Indoorunits:7xEKHVMyD50A

    a typiCal Residentialinstallation

    daikin altheRma flex type:

  • 13

    HeatingcapacitybelowTa-15Cnotgaranteed

    Tdesign=-8C Requiredheatingcapacity=32.5kW

    Selectedoutdoorunit=16HP

    Connection ratio = = 95%

    Heatload Indoorclass CapacityindexApartment7 6.0kW 80class 80Apartment6 4.5kW 50class 50Apartment5 4.5kW 50class 50Apartment4 4.5kW 50class 50Apartment3 4.5kW 50class 50Apartment2 4.0kW 50class 50Apartment1 4.5kW 50class 50total heating capacity: 32.5 kw

    total capacity index: 380

    2. Defineheatloadsforeachapartmentandtheappropriateindoorandoutdoorunits:

    Theoreticalcalculation

    1. Definedesigntemperature

    Tdesign=-8C

    3. Checkthecapacityindex

    Connectionratio=

    Whenselectinganoutdoorunit,thetotalcapacityindexmustbeascloseaspossibletothenominalcapacityindex.

    380400

    totalcapacityindex

    nominalcapacityindex

    DaikinAlthermaFlexTypesimulationsoftwareallowsdimensioningofaDaikinAlthermasystem inonlya fewsteps.Thesimulationsoftwareautomaticallypresentsallthespecificationsrequiredfordimensioningthewholesystem(inaclearreport).

    Selectionofindoorunits,hotwatertankandoptions Selectionofappropriateoutdoorunit Checkingpipinglengthsandheightdifferences Installationspecifications:refrigerantpipingdiameters,

    refnetjointsandheaders,additionalrefrigerantcharge,wiringdiagram.

    connectionratiooutdoorunit50% 100% 130%min nom max

    8HP 100 200 26010HP 125 250 32512HP 150 300 39014HP 175 350 45516hp 200 400 520380

    Simulationsoftware

    12,7X28,6X19,1

    9,5X22,2X19,1

    9,5X22,2X19,1

    9,5X19,1X15,9

    9,5X15,9X12,7

    KHRQ23M64T

    KHRQ23M64T

    KHRQ23M29T

    KHRQ23M29T

    KHRQ23M20T

    KHRQ23M20T

    9,5X15,9X12,7

    9,5X15,9X12,7

    9,5X15,9X12,7

    9,5X15,9X12,7

    9,5X15,9X12,7

    9,5X15,9X12,7

    9,5X15,9X12,7

    Calculation

    45

    40

    35

    30

    25

    20

    15

    10

    5

    0

    -20 -15 -10 -5 0 5 10 15

    8HP10HP12HP14HP16HP

    Ta(C)

    capa

    city(K

    W)

    >

    >

    >

    >

    >

    >

    >

  • daikin altheRma flex type:the flexible heating solution

    DaikinAlthermaFlexTypewithitsinnovativecombinationofheating,coolingandhotwaterproductioninonesystem,isarealaddedvalueforanyAPARTMEnTOWnER.Itisthefirstsystemforapartmentsandcollectivehousingthatfullyallowstheuseofrenewableenergysources.

    Makinguseofrenewableenergyintheformoftheheatfromtheoutsideairandrecoveredfromthecoolingcycle,thesystemprovidesenergyefficientandinexpensivehotwaterthusreducingtheheatingcostsincomparisontoaconventionalheatingsystem.Itsefficient,air-to-waterheatpumptechnologycontributestowardsmakingtodaysapartmentbuildingsmoreenvironmentallysustainable,withlowerrunningcosts,reducedCO2emissions,andreducedprimaryenergyusage.

    ThemodulardesignoftheDaikinAlthermaFlexTypeallowsCOnSULTAnTSandARCHITECTStoincorporatethesysteminanydevelopmentproject.Atypicalinstallationincludesoneoutdoorunit(from23to45kW)foruptotenindoorunits.Multipleoutdoorunitscanbeinstalledforlargerapplications.

    Theoutdoorunitextractsheatfromtheoutdoorair,raisesandtransfersitatintermediatetemperaturetotheindividualindoorunits(6,9,11,14and16kW).Theindoorunitsthenraisethetemperaturefurtherandfeedheatedwatertoradiators,heatpumpconvectorsorunderfloorheatingunits.Ifnecessary,theindoorunitcanalsoprovidecooling.

    14

  • impRove the ComfoRt levels thRough heating and Cooling possibilities

    ReduCe the development and exeCution time of youR pRojeCt!

    DaikinAlthermaFlexTypecombinesthebestofDaikinsKnOWHOW:

    Daikin VRV technology continuously adjusts the circulating refrigerant volumein response to loadvariations in the indoorunits.Thisallows the indoorunits tooperateindependentlyofeachother,assuringtotalflexibilityperapartment,withindividualcontrolofheating,hotwaterandcooling.

    Highly efficient, inverter-controlled compressors, with variable operating point,optimally control theheat emission temperature, resulting inmaximumcomfortandminimumenergyconsumption.

    Heatrecoverymakesoptimumuseoftheenergyconsumedforcoolingandreduceselectricitycosts.

    Daikin Altherma Flex Type range is designed to be InSTALLED QUICKLy AnDFLEXIBLy:

    The indoor units are fully equippedwith all the requiredhydraulic components,andcanbeconnecteddirectlytotheheatdistributionsystem.Thehotwatertankscanbestackedontheindoorunits.Thislimitsthefootprint(

  • 16

    Introduction 17

    Efficientclimatecontrolforcommercialapplication 18

    Fitforpurposehotwaterondemand 19

    TwoDaikintechnologiescombined 20

    Severalconfigurationsarepossibletosuitanycommercialapplication 22

    Morebenefitstoconsultantsinstallersandendusers 28

    Specifications 30

    a Renewable solution foR commercial appliCation

    new >

  • Providing total climate control in places as SCHOOLS, HOSPITALS,

    LIBRARIES, SPAS, FITnESS CEnTRES AnD HOTELS presents

    particular challenges. Most of the time there are a large number

    of rooms of greatly varying sizes that require heating and cooling

    while, at the same time large volumesof hotwater are alsoneeded.

    DaikinAlthermaFlexTypeisdesignedwiththischallengeinmind.Each

    outdoorunitcanbelinkedtouptotenindoorunits,witheachindoor

    unitbeingindividuallycontrolled,tomakesuretheperfecttemperature

    ismaintainedatalltimes. Inaddition,bymakingoptimaluseofVRV,

    cascadetechnologyandheatpumptechnologies,thesystemefficiently

    generateshotwaterinbothheatingandcoolingmodes.

    heating hot wateR Cooling

    only one system

    17

  • 18

    EnergyefficientheatpumptechnolgyDaikin Altherma Flex Type is todays answer to current andfuture issues of increasing energy costs and unacceptableenvironmental impact associated with conventional heatingsystemsforcommercialapplicationssuchasschools,hospitals,spas,gymsandhotels.WithDaikinAlthermaFlexType,2/3ofthegeneratedheatcomesfromtheair,which isa renewableenergysourcethatisfreeofcharge!DaikinAlthermaFlexTypeachievesatypicalseasonalCOPof3inthemoderateWesternandcentralEuropeanclimate.Compared toanoilboiler, thisresultsin:Upto36%lessrunningcosts*Upto71%reductionofCO2emissions*Upto35%reductioninprimaryenergyuse*

    *DatacalculatedtakinginaccountBelgianconditions:SCOPof3,averageenergyprices2007-2010,CO2emissionfactorforelectricityproduction

    effiCient Climate ContRol

    foR CommeRCial appliCation

    ModularsystemOne ormore inverter-controlled outdoor heat pump units canprovideheating,coolingandhotwater.Outdoorunitsbetween23and45kWextracttheheatfromtheoutdoorair,raiseittoanintermediate temperature and transfer this heat energy to theindividualindoorunits.

    Indoorunitsareavailableinseveralclasses(6,9,11,14and16kW),ensuringoptimumefficiency.Oneoutdoorunitcanbecombinedwithuptotenindoorunits.Multipleoutdoorunitscanbeinstalledforlargerapplications.

    3-in-1systemDaikin Altherma FlexType heats, cools and produces domestichotwater: Heating:leavingwatertemperaturesupto80C Cooling:leavingwatertemperaturesdownto5C Hotwater:tanktemperaturesupto75CThanks to the heat recovery function, the system can heat upthe hotwater tank up to 60Cwith rejectedheat from coolingoperation.

    Runningcost

    Cond

    ensing

    gas

    daikin alth

    erma flex typ

    e

    fuel

    82%

    100%

    29%

    CO2emissions

    100%

    73%

    PrimaryenergyEfficiency

    92%

    120%

    89%68%

  • 19

    fit foR puRpose hot wateR on demand

    Modularsystem

    1COMMERCIALSPACE TOTALBUILDIng

    20kW

    22kW

    40kW

    45kW Installseparateoutdoorunitstoreachhighercapacities(Separatesystem:theoutdoorunitsarenotconnectedtoeachother)

    note:Heatingcapacities7Cambienttemperature,coolingcapacities35Cambienttemperature

    3P,400V1P,230V

    6kW 9kW 11kW 14kW 16kW

    Thechallengesforafitnesscenter: Largeexerciseroomswithhighlevels

    of heat being generated requiringrigorous climate control throughoutthespace

    Highon demand hotwater usage inthechangingrooms

    Thesolution:DaikinAlthermaFlexTypewithitsmodularandflexibleapproach.

    5kW 8kW

  • 20

    SpaceheatingDaikinAlthermaFlexTypeusestworefrigerantcycles,R-410AandR-134a,toheatthewatercircuit.Thepurposeofacascadesystemistoattainorworkwithpressuresandtemperatureswhichcannotbereachedbyusingonlyonerefrigerantcycle.Theaimistogetthebestcharacteristicsoutofthetwoactivecycles.Ther-410arefrigerantcircuithasexcellentcharacteristicswithrespecttolowevaporatingtemperatures,whilether-134acircuithasexcellentcharacteristics for high condensing temperatures. With thecascadetechnology,both refrigerantsareoperatingunder theiroptimalconditions.

    the advantages of cascade technology versus single refrigerant cycle heat pumps: Widewatertemperaturerange(25C80C):alltypesofheat

    emitterscanbeconnected(underfloorheating,fancoilunits,radiators). Existing radiators can also be connected to theDaikinAlthermaFlexTypesystem.

    nodropofefficiencywithincreasingwatertemperatures. Highcapacitiesatlowambienttemperatures. noelectricalheaterrequired.

    HotwaterheatingThankstothecascadetechnology,DaikinAlthermaFlexTypecanreachwatertemperaturesof75Ctoheatupthehotwatertank.Thismakesitahighlyefficientsystemfortheproductionofhotwater.

    Hotwatercanbeproducedupto75C,withouttheassistanceofanelectricheater

    noelectricheaterrequiredforLegionelladisinfection SeasonalCOPof3.0forheatingfrom15Cto60C Heat-uptimefrom15to60Cin70minutes(200Ltank) Equivalent hot water volume of 320L at 40C (without

    reheat)fora200Ltankatatanktemperatureof60C.Highervolumesofequivalenthotwaterareavailablewiththe260ltank,orbyusingahighertanktemperature.

    CoolingThesecond refrigerant cycleR-134acanbebypassed toofferefficientcooling.TheR-410A refrigerantcycle is reversed,andthecoolwatercircuitcanbeusedtocooltherooms.

    Highcoolingcapacitieswithwater temperaturesdown to5C, in combinationwith Daikin heat pump convector orDaikinfancoilunits

    Under floor cooling is possible, with water temperaturesdownto18C

    Heat from cooling operation can be recovered to heatthehotwatertank

    two daikin teChnologies CombinedindooR unit: daikin altheRma CasCade teChnology

    Outdoor indoor

    1 2 3Step Step Step

    Highperformancein3steps:

    1. Theoutdoorunitextractsheatfromtheambientoutdoorair.ThisheatistransferredtotheindoorunitviatheR-410Arefrigerant.

    2. The indoor unit receives the heat and furtherincreasesthetemperaturewiththeR-134arefrigerant.

    3. TheheatistransferredfromtheR-134arefrigerantcircuittothewatercircuit.Thankstotheuniquecascadecompressor,watertemperaturesof80Ccanbereachedwithoutusinganadditionalbackupheater.

  • 21

    ModularflexibilityDaikinAlthermaFlexTypemakesuseofDaikinsrenownedVRVtechnology. A combination of Proportional Integral Derivativecontrolled compressors and electronic expansion valves in theoutdoorunitcontinuouslyadjuststhecirculatingrefrigerantvolumeinresponsetoloadvariationsintheconnectedindoorunits.

    The VRV technology allows multiple indoor units to beconnectedtoasingleoutdoorunitandtheindoorunitstooperateindependentlyofeachother,assuringtotalflexibility.

    InvertercompressorsDaikin Altherma owes its remarkable low energy consumptionto a unique combination of highly efficient inverter-controlledDaikin compressorswith a variable operatingpoint.This allowscapacity to be exactlymatched to the actual heating demandof the building.The ability to fully control the heat capacity oftheoutdoor unit alsomeansmaximumcomfort andminimumenergyconsumption.

    outdooR unit: daikin vRv teChnology

    Heating:upto80C

    Cooling*:downto5C

    Hotwaterheating:

    upto75C

    -20Ccooling

    upto

    43C

    discharge

    liquid

    suction

    R-410a

    R-410a

    R-134a

    h2o

    HeatrecoveryHeatabsorbedwhilecoolingonearea,canberecoveredinsteadofbeingsimplyreleasedintotheair.Thisrecoveredheatcanbeusedinananotherarea:

    forhotwaterproduction forspaceheatingandhotwaterproduction

    Withtheheatrecoveryfunction,theavailableenergyismaximallyused,thusreducingelectricitycosts.

    *onlyavailableon6and9kW

    downto

    >

    >

    >

    >

    >

    >

    >

    heating

    >

    ambienttemperature

    ambienttemperature

  • 22

    CommeRCial appliCation

    seveRal ConfiguRations aRe possible to suit any

  • 23

    multiple t zones

    TheperfectheatingsystemInplacesthatrequireheating-ratherthancooling-suchashospitals,fitnesscentresandschools,DaikinAlthermaFlexTypecanbeconfiguredtoprovidecontrollableheatingvia radiators, heat pump convectors and under floor heating.Thismeans a range oftemperaturesneeds tobeavailable from35C forunderfloorheatingup to80C forradiators.Todothiscosteffectivelywithminimalenergyusageacombinationofheatpumpswithcascadetechnologyistheidealsolution.

    Indoorunit

    radiators~80Cheatpumpconvectors~45Cunderfloorheating~35C

    23kW 160kW ~(500kW)

    trD Temperaturereducingdevice

    p1/p2/p3 Secondarycirculationpumps

    rt1 RoomThermostat1

    rt2 RoomThermostat2

    rt3 RoomThermostat3

    ~80C~80C rt3

    rt1

    rt2trD2p3

    p1

    p2

    trD1

    ~45C

    ~35C

    System1 System2 System3 System4 Systemn

    UnitnUnit1

    700mm

    ConsoleDaikin

    600mm

    600mm

    2000mmRadiateur standard basse temprature

    700mm

    ConsoleDaikin

    600mm

    600mm

    2000mmRadiateur standard basse temprature

    700mm

    ConsoleDaikin

    600mm

    600mm

    2000mmRadiateur standard basse temprature

  • 24

    hot wateR on demandwith shoRt Reheat time

    peak demand with longeR Reheat time

    oR

    HotwaterproductionStorageoperationAt a pre-programmed timeof theday, during lowenergytariffperiods,theindoorunitwillheatupthehotwatertanktoahighstoragetemperatureofabout75C.ReheatoperationTo guarantee sufficient hot water throughout the day,the indoor unit will keep the tank at the pre-set reheattemperature.TankvolumeaccordingtoyourneedsSometimes very large volumesof hotwater areneeded.That is why the Daikin Altherma Flex Type can beconnectedtoalltankvolumes. Inordertohaveacorrectdimensioning of your specific hot water requirements,contactyourlocaldealer.

  • 25

    oR

    oR

    Example1

    6xEKHTS260at70C6x500lwaterat40Cavailable

    1unitpertankinstalledshortreheattime

    Example2

    6xEKHTS260at70C6x500lwaterat40Cavailable

    1unitper3tanksinstalledlongerreheattime

    Example3

    AllflexibilityWhatever

    hotvolumesrequiredWhatever

    reheattimerequired

    ~80C

    System1 System2 System3 System4 Systemn

    UnitnUnit1

    Hotwaterproduction

  • 26

    heating hot wateR and Cooling, aCCoRding to youR needs

  • 27

    Eachspace in thebuildinghas itsownthermostat that is linked to themaincontrolpanel.Withthemaincontrolpanel,therequiredoptimaltemperaturesforeachspacecanbesetandmonitoredbyactivatingindoorunitsintherequiredmode.Astheheatpumponlyproducesthehighest(heating)orlowest(cooling)desiredtemperature.Theenergyconsumptionandoperatingcostswillbereduced.

    Whenhighcapacitiesareneededforcooling,anairhandlingunitcanbeaddedtothesystem.

    Cooling

    p1/p2 = secondary circulation pumpsdat = discharge air thermostattRd = temperature reducing deviceRt = Room thermostat

    System1 System2 System3 Systemn

    160kW120kW80kW40kW ~(500kW)23kW

    80C 5C

    35C 20C

    p1

    p2

    trD rt

    Dat

    heating25Cto 80C

    cooling20Cto5C

    3 in 1 system

  • 28

    moRe benefitsto Consultants, installeRs

    and end useRs

  • 29

    Cascadetechnologyhighefficiencyupto80CTheuseofcascadetechnologyallowsthesystemtoworkveryefficiently over a wide temperature range right up to 80C.Thehighesttemperatureproducedisthatwhichisrequiredbytheunitsduringoperationandthisensuresthatextraenergyisnotconsumedbeyondtheneedatthetime.

    QuickheatuptimeThecombinationofheatpumpandcascadetechnologyallowsfor rapid heat up times, not only in terms of space heatingbutalso forhotwater this canbeparticularly important inapplications, such as fitness centres, where spaces with lowheating demand are counter-balanced by spaces with highpeak demand. The heat from one area can be recovered,instead of releasing it to the outside air, and can bereusedforheatingorhotwaterproductionthusreducingtheheatuptimeandsoloweringoperatingcosts.

    ModularDesignDaikinAlthermaFlexTypemakesuseofDaikins renownedtechnology.Also,multipleindoorunitscanbeconnectedtoasingleoutdoorunit.Thisallowstheindoorunitstooperateindependently of each other, assuring total flexibility, andtotal climate controlwith temperatures set at the optimalvaluesfortheparticularspace.

    29

    ReducethedevelopmentandexecutiontimeofyourprojectBymaking use of our selection and dimensioning tools, it iseasy todesign a single solution forheating, cooling andhotwater. Our advanced piping design and the elimination ofexhaust systemsallows foreasy integration intoanybuildingthussavingoninstallationtimeandaddingvaluetotheproject.

    Quickinstallation!Our systems are dispatched from the factory with all thehydraulic components pre-fitted and ready to be connectedto the external piping. This makes them quicker and easierto install and so saves you time and the need for on-siteconfiguration,especiallywhenmultipleelementsareinvolved.Installinghotwater tanksontopof thesystems indoorunitsusingourplug-and-playfunctionalitycansaveadditionaltimeandtheeliminationoftheneedforachimneyorotherexhaustfittingavoidsadditionalwork.

    UsecleanenergyTheuseofadvancedheatpumptechnologythatcapturesheatfromtheaircan reduce theenergyconsumedbyupto75%.This saves on heating costs and reduces the environmentalimpactofthesystemwhileoptimalperformanceinhotwaterproduction,heatingandevencoolingisretained.

  • 30

    ekhVmrD50a ekhVmrD80a ekhVmyD50a ekhVmyD80a

    Function Heatingonly Heatingandcooling

    Dimensions HxWxD mm 705x600x695 705x600x695

    Leavingwatertemperaturerange

    heating C 25~80 25~80

    Material Precoatedsheetmetal Precoatedsheetmetal

    Colour Metallicgrey Metallicgrey

    Soundpressurelevel nominal dB(A) 401/432 421/432 401/432 421/432

    Weight kg 92 120

    RefrigerantType R-134a R-134a

    Charge kg 2 2 2 2

    Powersupply 1~/50Hz/220-240V 1~/50Hz/220-240V

    1Soundlevelsaremesuredat:EW55C;LW65C2Soundlevelsaremesuredat:EW70C;LW80C

    indoor unit

    indoor unit

    speCifiCations

    ekhBrD011acV1 ekhBrD014acV1 ekhBrD016acV1 ekhBrD011acy1 ekhBrD014acy1 ekhBrD016acy1

    Casing Colour MetallicgreyMaterial Precoatedsheetmetal

    Dimensions Unit Height/Width/Depth mm 705/600/695Weight Unit kg 144.25 147.25Operationrange

    Heating Ambient Min.~Max. C -20~20Waterside Min.~Max. C 25~80

    Domestichotwater

    Ambient Min.~Max. CDB -20~35Waterside Min.~Max. C 25~80

    Refrigerant Type R-134aCharge kg 3.2

    Soundpressurelevel

    nom. dBA 43(5)46(6)

    45(5)46(6)

    46(5)46(6)

    43(1)46(2)

    45(1)46(2)

    46(1)46(2)

    nightquietmode

    Level1 dBA40(5) 43(5) 45(5) 40(1) 43(1) 45(1)

    Powersupply name V1 y1Phase 1~ 3~Frequency Hz 50Voltage V 220-240 380-415

    Current Recommendedfuses A 25 16

    (1)EW55C;LW65C;Dt10C;ambientconditions:7CDB/6CWB|(2)EW70C;LW80C;Dt10C;ambientconditions:7CDB/6CWB|(3)EW30

  • 31

    outdoor unit

    heat pump convectorFwxV15a FwxV20a

    CapacityHeating 45C1 kW 1.5 2.0

    Cooling 7C2 kW 1.2 1.7

    Dimensions HxWxD mm 600x700x210

    Weight kg 15

    Airflowrate H/M/L/SL m3/h 318/228/150/126 474/354/240/198

    Soundpressure M dB(A) 19 29

    Refrigerant Water

    PowerSupply 1~/220-240V/50/60Hz

    Pipingconnections Liquid(OD)/Drain 12.7/20

    emrQ8ay1 emrQ10ay1 emrQ12ay1 emrQ14ay1 emrQ16ay1

    nominalcapacityheating kW 22.4 28 33.6 39.2 44.8

    cooling kW 20 25 30 35 40

    Capacityrange HP 8 10 12 14 16

    Dimensions HxWxD mm 1680x1300x765

    Weight kg 331 339

    Soundpowerlevel heating dB(A) 78 80 83 84

    Soundpressurelevel heating C 58 60 62 63

    Operationrangeheating C -20C~20*

    domesticwater C -20C~35*

    Refrigerant type kg R-410A

    Powersupply 3~/50Hz/380-415V

    Pipingconnections

    liquid mm 9.52 12.7

    suction mm 19.1 22.2 28.6

    high&lowpressuregas 15.9 19.1 22.2

    maxtotallength m 300

    leveldiffernceOU-IU m 40

    Recommendedfuses A 20 25 40

    Heatingconditions:Ta=7CDB/6CWB,100%connectionratioCoolingconditions:Ta=35CDB,100%connectionratio*Capacitynotguaranteedbetween-20Cand-15C

    1 Waterinlettemperature=45C/Wateroutlettemperature:40C indoortemperature=20CDB Mediumfanspeed2 Waterinlettemperature=7C/Wateroutlettemperature:12C indoortemperature=27CDB/19CWB Mediumfanspeed

    ekhts200ac ekhts260acWatervolume l 200 260Max.watertemperature C 75CDimensions HxWxD mm 1,335x600x695 1,610x600x695Dimensions-integratedonindoorunit

    HxWxD mm 2,010x600x695 2,285x600x695

    Materialoutsidecasing galvanisedmetalColour MetallicgreyEmptyweight kg 70 78

    hot water tank

    ekhBrD011acV1 ekhBrD014acV1 ekhBrD016acV1 ekhBrD011acy1 ekhBrD014acy1 ekhBrD016acy1

    Casing Colour MetallicgreyMaterial Precoatedsheetmetal

    Dimensions Unit Height/Width/Depth mm 705/600/695Weight Unit kg 144.25 147.25Operationrange

    Heating Ambient Min.~Max. C -20~20Waterside Min.~Max. C 25~80

    Domestichotwater

    Ambient Min.~Max. CDB -20~35Waterside Min.~Max. C 25~80

    Refrigerant Type R-134aCharge kg 3.2

    Soundpressurelevel

    nom. dBA 43(5)46(6)

    45(5)46(6)

    46(5)46(6)

    43(1)46(2)

    45(1)46(2)

    46(1)46(2)

    nightquietmode

    Level1 dBA40(5) 43(5) 45(5) 40(1) 43(1) 45(1)

    Powersupply name V1 y1Phase 1~ 3~Frequency Hz 50Voltage V 220-240 380-415

    Current Recommendedfuses A 25 16

    (1)EW55C;LW65C;Dt10C;ambientconditions:7CDB/6CWB|(2)EW70C;LW80C;Dt10C;ambientconditions:7CDB/6CWB|(3)EW30

  • 32

    naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

    Daikinproductsaredistributedby:

    ThepresentleafletisdrawnupbywayofinformationonlyanddoesnotconstituteanofferbindinguponDaikinEuropen.V..DaikinEuropen.V.hascompiledthecontentofthisleaflettothebestofitsknowledge.noexpressor impliedwarranty isgivenfor thecompleteness,accuracy, reliabilityor fitness forparticularpurposeofitscontentandtheproductsandservicespresentedtherein.Specificationsaresubjecttochangewithoutpriornotice.DaikinEuropen.V.explicitlyrejectsany liability foranydirector indirectdamage, inthebroadest sense, arising fromor related to theuse and/or interpretationof this leaflet. All content iscopyrightedbyDaikinEuropen.V.

    FSC

    ECPEn12-727

    Daikins unique position as a manufacturer of airconditioning equipment, compressors and refrigerantshasledtoitscloseinvolvementinenvironmentalissues.ForseveralyearsDaikinhashadtheintentiontobecomea leader in the provision of products that have limitedimpact on the environment. This challenge demandsthe eco design and development of a wide rangeof products and an energy management system,resulting in energy conservation and a reductionofwaste.

    ECPE

    n12

    -727

    10

    0010

    /11C

    opyrightDaikin

    Printedon

    non

    -chlorinated

    pap

    er.Prepa

    redby

    la mov

    ida, Belgium

    Re

    sp.Ed.:D

    aikinEu

    rope

    n.V.,Z

    andv

    oordestraat3

    00,B-840

    0Oostend

    e