DESCRIPTION
DAIKIN
Citation preview
Topcomfort
Heating,hotwaterandcooling
LowCO2emissions
Modularsystem
Daikin altherma Flex type
www. d a i k i n a l t h e rm a . e u
Res ident i a l and Commerc i a l app l i ca t ions
2Daikin altherma Flex type: a centraliseD heating, hot water anD cooling system For resiDential anD commercial applications
3Forthelast50years,wehavebeentheleading innovatoRinthe
heatpump industry.Becauseof thisconstant focuson innovation,
we were the first to deliver total Climate ContRol that
RespeCts the enviRonment, ishighlyeneRgy effiCient and
Cost effeCtive.
TheDaikinAlthermaFlexTyperangeisthedirectresultofthoseyears
ofresearch,innovationandcontinuousqualityimprovement.Alwaysat
theleadingedgeofclimatecontrol,wespendourtimelisteningtowhat
ourcustomerswantandthendeliveringtomorrowstechnologytoday.
TheDaikinAlthermaFlexTyperangeisamixofintelligentsolutionsand
advancedcontroltechnologiesthatprovidestheultimateincontrollable
comfortforresidentialandcommercialbuildingswhilerespectingthe
environmentthroughreducedenergyconsumption.
Astheproviderofchoiceforthosewhoonlywantthebestinclimate
control, weContinuously innovate so that otheRs need
to follow ouR lead.
2 >17
18 >40
Introduction 5
Efficientclimatecontrolforapartmentbuildings 6
TwoDaikintechnologiescombined 8
Daikinheatpumpconvector 10
Morebenefitsofadvanceddesign 11
DaikinAlthermaFlexType:atypicalinstallation 12
DaikinAlthermaFlexType:theflexibleheatingsolution 14
Specifications 30
duRable & effiCient eneRgy solutions foR resiDential appliCation
4
Providingtotalclimatecontrolinanapartmentbuildingorincollective
housing presents a particular challenge because a large number of
roomssimultaneouslyneedheatingorcooling.
DaikinAlthermaFlexTypeisdesignedwiththischallengeinmind.Each
outdoorunitcanbelinkedtouptotenindoorunits,witheachindoor
unitbeingindividuallycontrolled,tomakesuretheperfecttemperature
ismaintainedatalltimes. Inaddition,bymakingoptimaluseofVRV,
cascadetechnologyandheatpumptechnologies,thesystemefficiently
generateshotwaterinbothheatingandcoolingmodes.
heating hot wateR Cooling
only one system
5
6EnergyefficientheatpumptechnolgyDaikin Altherma Flex Type is todays answer to current andfutureissuesofincreasingenergycostsandunacceptablehighenvironmental impact associated with conventional heatingsystems.WithDaikinAlthermaFlexType,2/3ofthegeneratedheatcomes from theair,which is recognisedasa renewableenergysourcethatisfreeofcharge!DaikinAlthermaFlexTypeachievesatypicalseasonalCOPof3inthemoderateWesternandcentralEuropeanclimate.Compared toanoilboiler, thisresultsin:Upto36%lessrunningcosts*Upto71%reductionofCO2emissions*
Upto35%reductioninprimaryenergyuse*
*DatacalculatedtakinginaccountBelgianconditions:SeasonalCOPof3,averageenergyprices2007-2010,CO2emissionfactorforelectricityproduction
effiCient Climate ContRol
foR apaRtment buildings and ColleCtive housing
ModularsystemOne ormore inverter-controlled outdoor heat pump units canprovideheating,coolingandhotwater.Outdoorunitsbetween23and45kWextracttheheatfromtheoutdoorair,raiseittoanintermediate temperature and transfer this heat energy to theindividualindoorunits.
Indoorunitsareavailableinseveralclasses(6,9,11,14and16kW),ensuringoptimumefficiency.Oneoutdoorunitcanbecombinedwithuptotenindoorunits.Multipleoutdoorunitscanbeinstalledforlargerapplications.
3-in-1systemDaikinAlthermaFlexTypeheats,coolsandproducesdomestichotwater: Heating:leavingwatertemperaturesupto80C Cooling:leavingwatertemperaturesdownto5C Hotwater:tanktemperaturesupto75CThanks to the heat recovery function, the system can heat upthe hotwater tank up to 60Cwith rejectedheat from coolingoperation.
100% 82% 68% 120% 92% 89% 100% 73% 29%PrimaryenergyEfficiency CO2emissionsRunningcost
Condensing gas
daikin altherma flex type
fuel
7outdoor
Oneormoreindoorandoutdoorunits
1
2
3
Modularsystem 1APARTMEnT TOTALBUILDIng
Oneormoreoutdoorunits+severalindoorunits>> amodularsystem
5kW 20kW
22kW
40kW
45kW
8kW
Installseparateoutdoorunitstoreachhighercapacities(Separatesystems:theoutdoorunitsarenotconnectedtoeachother)
note:Heatingcapacities7Cambienttemperature,Coolingcapacities35Cambienttemperature3P,400V1P,230V
Outdoorunit IndoorinstallationDomestichotwatertank
= +
Heating/Cooling
Indoorunit
6kW 9kW 11kW 14kW 16kW
ConCept desCRiption
Hotwater1
2Heating
3Cooling
8SpaceheatingDaikinAlthermaFlexTypeusestworefrigerantcycles,R-410AandR-134a,toheatthewatercircuit.Thepurposeofacascadesystemistoattainorworkwithpressuresandtemperatureswhichcannotbereachedbyusingonlyonerefrigerantcycle.Theaimistogetthebestcharacteristicsoutofthetwoactivecycles.Ther-410arefrigerantcircuithasexcellentcharacteristicswithrespecttolowevaporatingtemperatures,whilether-134acircuithasexcellentcharacteristics for high condensing temperatures. With thecascadetechnology,both refrigerantsareoperatingunder theiroptimalconditions.
the advantages of cascade technology versus single refrigerant cycle heat pumps: Widewatertemperaturerange(25C80C):alltypesofheat
emitterscanbeconnected(underfloorheating,fancoilunits,radiators). Existing radiators can also be connected to theDaikinAlthermaFlexTypesystem.
nodropofefficiencywithincreasingwatertemperatures. Highcapacitiesatlowambienttemperatures. noelectricalheaterrequired.
HotwaterheatingThankstothecascadetechnology,DaikinAlthermaFlexTypecanreachwatertemperaturesof75Ctoheatupthehotwatertank.Thismakesitahighlyefficientsystemfortheproductionofhotwater.
Hotwatercanbeproducedupto75C,withouttheassistanceofanelectricheater
noelectricheaterrequiredforLegionelladisinfection SeasonalCOPof3.0forheatingfrom15Cto60C Heat-uptimefrom15to60Cin70minutes(200Ltank) Equivalent hot water volume of 320L at 40C (without
reheat)fora200Ltankatatanktemperatureof60C.Highervolumesofequivalenthotwaterareavailablewiththe260ltank,orbyusingahighertanktemperature.
CoolingThesecond refrigerant cycleR-134acanbebypassed toofferefficientcooling.TheR-410A refrigerantcycle is reversed,andthecoolwatercircuitcanbeusedtocooltherooms.
Highcoolingcapacitieswithwater temperaturesdown to5C, in combinationwith Daikin heat pump convector orDaikinfancoilunits
Under floor cooling is possible, with water temperaturesdownto18C
Heat from cooling operation can be recovered to heatthehotwatertank
two daikin teChnologies CombinedindooR unit: daikin altheRma CasCade teChnology
Outdoor indoor
1 2 3Step Step Step
Highperformancein3steps:
1. Theoutdoorunitextractsheatfromtheambientoutdoorair.ThisheatistransferredtotheindoorunitviatheR-410Arefrigerant.
2. The indoor unit receives the heat and furtherincreasesthetemperaturewiththeR-134arefrigerant.
3. TheheatistransferredfromtheR-134arefrigerantcircuittothewatercircuit.Thankstotheuniquecascadecompressor,watertemperaturesof80Ccanbereachedwithoutusinganadditionalbackupheater.
9ModularflexibilityDaikinAlthermaFlexTypemakesuseofDaikinsrenownedVRVtechnology. A combination of Proportional Integral Derivativecontrolled compressors and electronic expansion valves in theoutdoorunitcontinuouslyadjuststhecirculatingrefrigerantvolumeinresponsetoloadvariationsintheconnectedindoorunits.
The VRV technology allows multiple indoor units to beconnected to a single outdoor unit and the indoor units tooperateindependentlyofeachother,assuringtotalflexibility.Eachapartmentretainscontrolofitsownheating,hotwaterandcooling.
InvertercompressorsDaikin Altherma owes its remarkable low energy consumptionto a unique combination of highly efficient inverter-controlledDaikin compressorswith a variable operatingpoint.This allowscapacity to be exactlymatched to the actual heating demandof the building.The ability to fully control the heat capacity oftheoutdoor unit alsomeansmaximumcomfort andminimumenergyconsumption.
outdooR unit: daikin vRv teChnology
Heating:upto80C
Cooling*:downto5C
Hotwaterheating:
upto75C
-20Ccooling
upto
43C
discharge
liquid
suction
R-410a
R-410a
R-134a
h2o
HeatrecoveryHeat absorbedwhile coolingoneapartment, canbe recoveredinsteadofbeingsimplyreleasedintotheair.Thisrecoveredheatcanbeused
forhotwaterproductioninthesameapartment forspaceheatingandhotwaterproductioninotherapartments
Withtheheatrecoveryfunction,theavailableenergyismaximallyused,thusreducingelectricitycosts.
*onlyavailableon6and9kW
downto
>
>
>
>
>
>
>
heating
>
ambienttemperature
ambienttemperature
10
TheDaikinheatpumpconvectoroperatesat typicalwater temperaturesof45C,which can be efficiently produced thanks to Daikin Altherma FlexType cascadetechnology.
The heat pump convector is therefore the ideal heat emitter for apartmentapplications,providinghighcomfortlevels: Smalldimensionscomparedtolowtemperature
radiators:widthisreducedwith2/3 Lowsoundleveldownto19dB(A),idealheatingandcoolingoperation
forbedrooms High-capacitycoolingwithwatertemperaturesdownto6C
HEATDEMAnDOn/OFF
livingroom OFF On OFF OFF
bathroom OFF OFF/On On OFF
bedroom OFF OFF/On OFF/On On
indoor unit off 65C 65C 45C
balancingvessel pumpradiators
externalcontrol
bathroom
Valvesclosedincoolingmode
mixingvalve
45C
65C
living room
ZOnE1:TLw=65C
ZOnE2:TLw=45C
bedroom
600m
m
600m
m
bedroom 1living room bedroom 2
Heating/CoolingoperationHeating(45C)/Cooling(6C)
45C/7C
Thankstoitswidewatertemperaturerange,alltypeofheatemitterscanbeconnectedtoDaikinAlthermaFlexType.Also,DaikinAlthermaFlexTypeisabletoworkwithmultiplesetpoints,allowingacombinationofdifferentheatemittersoperatingatdifferentwatertemperatures.Thesetpointof the indoorunitwill automaticallybe lowered in functionof theactualdemandof thevariousheatemitters,ensuringoptimumefficiencyatalltimesandunderallconditions.
the optimal heat emitteR foR apaRtments
daikin heat pump ConveCtoR:
heatpumpconvectors
11
moRe benefits of advanCed design
MODULARDESIgnThemodulardesignenablesflexibleandeasyinstallation-thisreducesthecostsandmakesmaintenanceeasier.
SMALLFOOTPRInTTheindoorunitscanbestackedorsetadjacenttoeachother.Thisensurestheunitstofitintoavailablesmallspacessothattheydonotimpingeonthelivingarea.
SILEnTOPERATIOnAdvancedmaterialsanddesignsallowallthemovingpartstooperateassilentaspossible,thusensuringthattheclimatecontrolsystemisbarelyaudible.
InDIVIDUALCOnTROLThelatestintegratedcontroltechnologiesallowthetemperatureofeachresidentialspacetobeindividuallyregulatedandmaintained.
HIgHEnERgy EFFICIEnCygIVESLOW OPERATIngCOSTS
Thecombinationoftechnologies,andespeciallyheatpumptechnology,meansthatmuchoftheheatingeffectcomesfromtheambientair.Thisreducestheenergyconsumptionandlowerstheoperatingcosts.
12
Description:Location:Ostend,Belgium
numberoffloors:8
Floorareaforoneapartment:115m2
Constructionyear:2008
Designconditioninwinter:-8C
Heatemitters:Daikinheatpumpconvectors
Outdoorunit:EMRQ16Ay1
Indoorunits:7xEKHVMyD50A
a typiCal Residentialinstallation
daikin altheRma flex type:
13
HeatingcapacitybelowTa-15Cnotgaranteed
Tdesign=-8C Requiredheatingcapacity=32.5kW
Selectedoutdoorunit=16HP
Connection ratio = = 95%
Heatload Indoorclass CapacityindexApartment7 6.0kW 80class 80Apartment6 4.5kW 50class 50Apartment5 4.5kW 50class 50Apartment4 4.5kW 50class 50Apartment3 4.5kW 50class 50Apartment2 4.0kW 50class 50Apartment1 4.5kW 50class 50total heating capacity: 32.5 kw
total capacity index: 380
2. Defineheatloadsforeachapartmentandtheappropriateindoorandoutdoorunits:
Theoreticalcalculation
1. Definedesigntemperature
Tdesign=-8C
3. Checkthecapacityindex
Connectionratio=
Whenselectinganoutdoorunit,thetotalcapacityindexmustbeascloseaspossibletothenominalcapacityindex.
380400
totalcapacityindex
nominalcapacityindex
DaikinAlthermaFlexTypesimulationsoftwareallowsdimensioningofaDaikinAlthermasystem inonlya fewsteps.Thesimulationsoftwareautomaticallypresentsallthespecificationsrequiredfordimensioningthewholesystem(inaclearreport).
Selectionofindoorunits,hotwatertankandoptions Selectionofappropriateoutdoorunit Checkingpipinglengthsandheightdifferences Installationspecifications:refrigerantpipingdiameters,
refnetjointsandheaders,additionalrefrigerantcharge,wiringdiagram.
connectionratiooutdoorunit50% 100% 130%min nom max
8HP 100 200 26010HP 125 250 32512HP 150 300 39014HP 175 350 45516hp 200 400 520380
Simulationsoftware
12,7X28,6X19,1
9,5X22,2X19,1
9,5X22,2X19,1
9,5X19,1X15,9
9,5X15,9X12,7
KHRQ23M64T
KHRQ23M64T
KHRQ23M29T
KHRQ23M29T
KHRQ23M20T
KHRQ23M20T
9,5X15,9X12,7
9,5X15,9X12,7
9,5X15,9X12,7
9,5X15,9X12,7
9,5X15,9X12,7
9,5X15,9X12,7
9,5X15,9X12,7
Calculation
45
40
35
30
25
20
15
10
5
0
-20 -15 -10 -5 0 5 10 15
8HP10HP12HP14HP16HP
Ta(C)
capa
city(K
W)
>
>
>
>
>
>
>
daikin altheRma flex type:the flexible heating solution
DaikinAlthermaFlexTypewithitsinnovativecombinationofheating,coolingandhotwaterproductioninonesystem,isarealaddedvalueforanyAPARTMEnTOWnER.Itisthefirstsystemforapartmentsandcollectivehousingthatfullyallowstheuseofrenewableenergysources.
Makinguseofrenewableenergyintheformoftheheatfromtheoutsideairandrecoveredfromthecoolingcycle,thesystemprovidesenergyefficientandinexpensivehotwaterthusreducingtheheatingcostsincomparisontoaconventionalheatingsystem.Itsefficient,air-to-waterheatpumptechnologycontributestowardsmakingtodaysapartmentbuildingsmoreenvironmentallysustainable,withlowerrunningcosts,reducedCO2emissions,andreducedprimaryenergyusage.
ThemodulardesignoftheDaikinAlthermaFlexTypeallowsCOnSULTAnTSandARCHITECTStoincorporatethesysteminanydevelopmentproject.Atypicalinstallationincludesoneoutdoorunit(from23to45kW)foruptotenindoorunits.Multipleoutdoorunitscanbeinstalledforlargerapplications.
Theoutdoorunitextractsheatfromtheoutdoorair,raisesandtransfersitatintermediatetemperaturetotheindividualindoorunits(6,9,11,14and16kW).Theindoorunitsthenraisethetemperaturefurtherandfeedheatedwatertoradiators,heatpumpconvectorsorunderfloorheatingunits.Ifnecessary,theindoorunitcanalsoprovidecooling.
14
impRove the ComfoRt levels thRough heating and Cooling possibilities
ReduCe the development and exeCution time of youR pRojeCt!
DaikinAlthermaFlexTypecombinesthebestofDaikinsKnOWHOW:
Daikin VRV technology continuously adjusts the circulating refrigerant volumein response to loadvariations in the indoorunits.Thisallows the indoorunits tooperateindependentlyofeachother,assuringtotalflexibilityperapartment,withindividualcontrolofheating,hotwaterandcooling.
Highly efficient, inverter-controlled compressors, with variable operating point,optimally control theheat emission temperature, resulting inmaximumcomfortandminimumenergyconsumption.
Heatrecoverymakesoptimumuseoftheenergyconsumedforcoolingandreduceselectricitycosts.
Daikin Altherma Flex Type range is designed to be InSTALLED QUICKLy AnDFLEXIBLy:
The indoor units are fully equippedwith all the requiredhydraulic components,andcanbeconnecteddirectlytotheheatdistributionsystem.Thehotwatertankscanbestackedontheindoorunits.Thislimitsthefootprint(
16
Introduction 17
Efficientclimatecontrolforcommercialapplication 18
Fitforpurposehotwaterondemand 19
TwoDaikintechnologiescombined 20
Severalconfigurationsarepossibletosuitanycommercialapplication 22
Morebenefitstoconsultantsinstallersandendusers 28
Specifications 30
a Renewable solution foR commercial appliCation
new >
Providing total climate control in places as SCHOOLS, HOSPITALS,
LIBRARIES, SPAS, FITnESS CEnTRES AnD HOTELS presents
particular challenges. Most of the time there are a large number
of rooms of greatly varying sizes that require heating and cooling
while, at the same time large volumesof hotwater are alsoneeded.
DaikinAlthermaFlexTypeisdesignedwiththischallengeinmind.Each
outdoorunitcanbelinkedtouptotenindoorunits,witheachindoor
unitbeingindividuallycontrolled,tomakesuretheperfecttemperature
ismaintainedatalltimes. Inaddition,bymakingoptimaluseofVRV,
cascadetechnologyandheatpumptechnologies,thesystemefficiently
generateshotwaterinbothheatingandcoolingmodes.
heating hot wateR Cooling
only one system
17
18
EnergyefficientheatpumptechnolgyDaikin Altherma Flex Type is todays answer to current andfuture issues of increasing energy costs and unacceptableenvironmental impact associated with conventional heatingsystemsforcommercialapplicationssuchasschools,hospitals,spas,gymsandhotels.WithDaikinAlthermaFlexType,2/3ofthegeneratedheatcomesfromtheair,which isa renewableenergysourcethatisfreeofcharge!DaikinAlthermaFlexTypeachievesatypicalseasonalCOPof3inthemoderateWesternandcentralEuropeanclimate.Compared toanoilboiler, thisresultsin:Upto36%lessrunningcosts*Upto71%reductionofCO2emissions*Upto35%reductioninprimaryenergyuse*
*DatacalculatedtakinginaccountBelgianconditions:SCOPof3,averageenergyprices2007-2010,CO2emissionfactorforelectricityproduction
effiCient Climate ContRol
foR CommeRCial appliCation
ModularsystemOne ormore inverter-controlled outdoor heat pump units canprovideheating,coolingandhotwater.Outdoorunitsbetween23and45kWextracttheheatfromtheoutdoorair,raiseittoanintermediate temperature and transfer this heat energy to theindividualindoorunits.
Indoorunitsareavailableinseveralclasses(6,9,11,14and16kW),ensuringoptimumefficiency.Oneoutdoorunitcanbecombinedwithuptotenindoorunits.Multipleoutdoorunitscanbeinstalledforlargerapplications.
3-in-1systemDaikin Altherma FlexType heats, cools and produces domestichotwater: Heating:leavingwatertemperaturesupto80C Cooling:leavingwatertemperaturesdownto5C Hotwater:tanktemperaturesupto75CThanks to the heat recovery function, the system can heat upthe hotwater tank up to 60Cwith rejectedheat from coolingoperation.
Runningcost
Cond
ensing
gas
daikin alth
erma flex typ
e
fuel
82%
100%
29%
CO2emissions
100%
73%
PrimaryenergyEfficiency
92%
120%
89%68%
19
fit foR puRpose hot wateR on demand
Modularsystem
1COMMERCIALSPACE TOTALBUILDIng
20kW
22kW
40kW
45kW Installseparateoutdoorunitstoreachhighercapacities(Separatesystem:theoutdoorunitsarenotconnectedtoeachother)
note:Heatingcapacities7Cambienttemperature,coolingcapacities35Cambienttemperature
3P,400V1P,230V
6kW 9kW 11kW 14kW 16kW
Thechallengesforafitnesscenter: Largeexerciseroomswithhighlevels
of heat being generated requiringrigorous climate control throughoutthespace
Highon demand hotwater usage inthechangingrooms
Thesolution:DaikinAlthermaFlexTypewithitsmodularandflexibleapproach.
5kW 8kW
20
SpaceheatingDaikinAlthermaFlexTypeusestworefrigerantcycles,R-410AandR-134a,toheatthewatercircuit.Thepurposeofacascadesystemistoattainorworkwithpressuresandtemperatureswhichcannotbereachedbyusingonlyonerefrigerantcycle.Theaimistogetthebestcharacteristicsoutofthetwoactivecycles.Ther-410arefrigerantcircuithasexcellentcharacteristicswithrespecttolowevaporatingtemperatures,whilether-134acircuithasexcellentcharacteristics for high condensing temperatures. With thecascadetechnology,both refrigerantsareoperatingunder theiroptimalconditions.
the advantages of cascade technology versus single refrigerant cycle heat pumps: Widewatertemperaturerange(25C80C):alltypesofheat
emitterscanbeconnected(underfloorheating,fancoilunits,radiators). Existing radiators can also be connected to theDaikinAlthermaFlexTypesystem.
nodropofefficiencywithincreasingwatertemperatures. Highcapacitiesatlowambienttemperatures. noelectricalheaterrequired.
HotwaterheatingThankstothecascadetechnology,DaikinAlthermaFlexTypecanreachwatertemperaturesof75Ctoheatupthehotwatertank.Thismakesitahighlyefficientsystemfortheproductionofhotwater.
Hotwatercanbeproducedupto75C,withouttheassistanceofanelectricheater
noelectricheaterrequiredforLegionelladisinfection SeasonalCOPof3.0forheatingfrom15Cto60C Heat-uptimefrom15to60Cin70minutes(200Ltank) Equivalent hot water volume of 320L at 40C (without
reheat)fora200Ltankatatanktemperatureof60C.Highervolumesofequivalenthotwaterareavailablewiththe260ltank,orbyusingahighertanktemperature.
CoolingThesecond refrigerant cycleR-134acanbebypassed toofferefficientcooling.TheR-410A refrigerantcycle is reversed,andthecoolwatercircuitcanbeusedtocooltherooms.
Highcoolingcapacitieswithwater temperaturesdown to5C, in combinationwith Daikin heat pump convector orDaikinfancoilunits
Under floor cooling is possible, with water temperaturesdownto18C
Heat from cooling operation can be recovered to heatthehotwatertank
two daikin teChnologies CombinedindooR unit: daikin altheRma CasCade teChnology
Outdoor indoor
1 2 3Step Step Step
Highperformancein3steps:
1. Theoutdoorunitextractsheatfromtheambientoutdoorair.ThisheatistransferredtotheindoorunitviatheR-410Arefrigerant.
2. The indoor unit receives the heat and furtherincreasesthetemperaturewiththeR-134arefrigerant.
3. TheheatistransferredfromtheR-134arefrigerantcircuittothewatercircuit.Thankstotheuniquecascadecompressor,watertemperaturesof80Ccanbereachedwithoutusinganadditionalbackupheater.
21
ModularflexibilityDaikinAlthermaFlexTypemakesuseofDaikinsrenownedVRVtechnology. A combination of Proportional Integral Derivativecontrolled compressors and electronic expansion valves in theoutdoorunitcontinuouslyadjuststhecirculatingrefrigerantvolumeinresponsetoloadvariationsintheconnectedindoorunits.
The VRV technology allows multiple indoor units to beconnectedtoasingleoutdoorunitandtheindoorunitstooperateindependentlyofeachother,assuringtotalflexibility.
InvertercompressorsDaikin Altherma owes its remarkable low energy consumptionto a unique combination of highly efficient inverter-controlledDaikin compressorswith a variable operatingpoint.This allowscapacity to be exactlymatched to the actual heating demandof the building.The ability to fully control the heat capacity oftheoutdoor unit alsomeansmaximumcomfort andminimumenergyconsumption.
outdooR unit: daikin vRv teChnology
Heating:upto80C
Cooling*:downto5C
Hotwaterheating:
upto75C
-20Ccooling
upto
43C
discharge
liquid
suction
R-410a
R-410a
R-134a
h2o
HeatrecoveryHeatabsorbedwhilecoolingonearea,canberecoveredinsteadofbeingsimplyreleasedintotheair.Thisrecoveredheatcanbeusedinananotherarea:
forhotwaterproduction forspaceheatingandhotwaterproduction
Withtheheatrecoveryfunction,theavailableenergyismaximallyused,thusreducingelectricitycosts.
*onlyavailableon6and9kW
downto
>
>
>
>
>
>
>
heating
>
ambienttemperature
ambienttemperature
22
CommeRCial appliCation
seveRal ConfiguRations aRe possible to suit any
23
multiple t zones
TheperfectheatingsystemInplacesthatrequireheating-ratherthancooling-suchashospitals,fitnesscentresandschools,DaikinAlthermaFlexTypecanbeconfiguredtoprovidecontrollableheatingvia radiators, heat pump convectors and under floor heating.Thismeans a range oftemperaturesneeds tobeavailable from35C forunderfloorheatingup to80C forradiators.Todothiscosteffectivelywithminimalenergyusageacombinationofheatpumpswithcascadetechnologyistheidealsolution.
Indoorunit
radiators~80Cheatpumpconvectors~45Cunderfloorheating~35C
23kW 160kW ~(500kW)
trD Temperaturereducingdevice
p1/p2/p3 Secondarycirculationpumps
rt1 RoomThermostat1
rt2 RoomThermostat2
rt3 RoomThermostat3
~80C~80C rt3
rt1
rt2trD2p3
p1
p2
trD1
~45C
~35C
System1 System2 System3 System4 Systemn
UnitnUnit1
700mm
ConsoleDaikin
600mm
600mm
2000mmRadiateur standard basse temprature
700mm
ConsoleDaikin
600mm
600mm
2000mmRadiateur standard basse temprature
700mm
ConsoleDaikin
600mm
600mm
2000mmRadiateur standard basse temprature
24
hot wateR on demandwith shoRt Reheat time
peak demand with longeR Reheat time
oR
HotwaterproductionStorageoperationAt a pre-programmed timeof theday, during lowenergytariffperiods,theindoorunitwillheatupthehotwatertanktoahighstoragetemperatureofabout75C.ReheatoperationTo guarantee sufficient hot water throughout the day,the indoor unit will keep the tank at the pre-set reheattemperature.TankvolumeaccordingtoyourneedsSometimes very large volumesof hotwater areneeded.That is why the Daikin Altherma Flex Type can beconnectedtoalltankvolumes. Inordertohaveacorrectdimensioning of your specific hot water requirements,contactyourlocaldealer.
25
oR
oR
Example1
6xEKHTS260at70C6x500lwaterat40Cavailable
1unitpertankinstalledshortreheattime
Example2
6xEKHTS260at70C6x500lwaterat40Cavailable
1unitper3tanksinstalledlongerreheattime
Example3
AllflexibilityWhatever
hotvolumesrequiredWhatever
reheattimerequired
~80C
System1 System2 System3 System4 Systemn
UnitnUnit1
Hotwaterproduction
26
heating hot wateR and Cooling, aCCoRding to youR needs
27
Eachspace in thebuildinghas itsownthermostat that is linked to themaincontrolpanel.Withthemaincontrolpanel,therequiredoptimaltemperaturesforeachspacecanbesetandmonitoredbyactivatingindoorunitsintherequiredmode.Astheheatpumponlyproducesthehighest(heating)orlowest(cooling)desiredtemperature.Theenergyconsumptionandoperatingcostswillbereduced.
Whenhighcapacitiesareneededforcooling,anairhandlingunitcanbeaddedtothesystem.
Cooling
p1/p2 = secondary circulation pumpsdat = discharge air thermostattRd = temperature reducing deviceRt = Room thermostat
System1 System2 System3 Systemn
160kW120kW80kW40kW ~(500kW)23kW
80C 5C
35C 20C
p1
p2
trD rt
Dat
heating25Cto 80C
cooling20Cto5C
3 in 1 system
28
moRe benefitsto Consultants, installeRs
and end useRs
29
Cascadetechnologyhighefficiencyupto80CTheuseofcascadetechnologyallowsthesystemtoworkveryefficiently over a wide temperature range right up to 80C.Thehighesttemperatureproducedisthatwhichisrequiredbytheunitsduringoperationandthisensuresthatextraenergyisnotconsumedbeyondtheneedatthetime.
QuickheatuptimeThecombinationofheatpumpandcascadetechnologyallowsfor rapid heat up times, not only in terms of space heatingbutalso forhotwater this canbeparticularly important inapplications, such as fitness centres, where spaces with lowheating demand are counter-balanced by spaces with highpeak demand. The heat from one area can be recovered,instead of releasing it to the outside air, and can bereusedforheatingorhotwaterproductionthusreducingtheheatuptimeandsoloweringoperatingcosts.
ModularDesignDaikinAlthermaFlexTypemakesuseofDaikins renownedtechnology.Also,multipleindoorunitscanbeconnectedtoasingleoutdoorunit.Thisallowstheindoorunitstooperateindependently of each other, assuring total flexibility, andtotal climate controlwith temperatures set at the optimalvaluesfortheparticularspace.
29
ReducethedevelopmentandexecutiontimeofyourprojectBymaking use of our selection and dimensioning tools, it iseasy todesign a single solution forheating, cooling andhotwater. Our advanced piping design and the elimination ofexhaust systemsallows foreasy integration intoanybuildingthussavingoninstallationtimeandaddingvaluetotheproject.
Quickinstallation!Our systems are dispatched from the factory with all thehydraulic components pre-fitted and ready to be connectedto the external piping. This makes them quicker and easierto install and so saves you time and the need for on-siteconfiguration,especiallywhenmultipleelementsareinvolved.Installinghotwater tanksontopof thesystems indoorunitsusingourplug-and-playfunctionalitycansaveadditionaltimeandtheeliminationoftheneedforachimneyorotherexhaustfittingavoidsadditionalwork.
UsecleanenergyTheuseofadvancedheatpumptechnologythatcapturesheatfromtheaircan reduce theenergyconsumedbyupto75%.This saves on heating costs and reduces the environmentalimpactofthesystemwhileoptimalperformanceinhotwaterproduction,heatingandevencoolingisretained.
30
ekhVmrD50a ekhVmrD80a ekhVmyD50a ekhVmyD80a
Function Heatingonly Heatingandcooling
Dimensions HxWxD mm 705x600x695 705x600x695
Leavingwatertemperaturerange
heating C 25~80 25~80
Material Precoatedsheetmetal Precoatedsheetmetal
Colour Metallicgrey Metallicgrey
Soundpressurelevel nominal dB(A) 401/432 421/432 401/432 421/432
Weight kg 92 120
RefrigerantType R-134a R-134a
Charge kg 2 2 2 2
Powersupply 1~/50Hz/220-240V 1~/50Hz/220-240V
1Soundlevelsaremesuredat:EW55C;LW65C2Soundlevelsaremesuredat:EW70C;LW80C
indoor unit
indoor unit
speCifiCations
ekhBrD011acV1 ekhBrD014acV1 ekhBrD016acV1 ekhBrD011acy1 ekhBrD014acy1 ekhBrD016acy1
Casing Colour MetallicgreyMaterial Precoatedsheetmetal
Dimensions Unit Height/Width/Depth mm 705/600/695Weight Unit kg 144.25 147.25Operationrange
Heating Ambient Min.~Max. C -20~20Waterside Min.~Max. C 25~80
Domestichotwater
Ambient Min.~Max. CDB -20~35Waterside Min.~Max. C 25~80
Refrigerant Type R-134aCharge kg 3.2
Soundpressurelevel
nom. dBA 43(5)46(6)
45(5)46(6)
46(5)46(6)
43(1)46(2)
45(1)46(2)
46(1)46(2)
nightquietmode
Level1 dBA40(5) 43(5) 45(5) 40(1) 43(1) 45(1)
Powersupply name V1 y1Phase 1~ 3~Frequency Hz 50Voltage V 220-240 380-415
Current Recommendedfuses A 25 16
(1)EW55C;LW65C;Dt10C;ambientconditions:7CDB/6CWB|(2)EW70C;LW80C;Dt10C;ambientconditions:7CDB/6CWB|(3)EW30
31
outdoor unit
heat pump convectorFwxV15a FwxV20a
CapacityHeating 45C1 kW 1.5 2.0
Cooling 7C2 kW 1.2 1.7
Dimensions HxWxD mm 600x700x210
Weight kg 15
Airflowrate H/M/L/SL m3/h 318/228/150/126 474/354/240/198
Soundpressure M dB(A) 19 29
Refrigerant Water
PowerSupply 1~/220-240V/50/60Hz
Pipingconnections Liquid(OD)/Drain 12.7/20
emrQ8ay1 emrQ10ay1 emrQ12ay1 emrQ14ay1 emrQ16ay1
nominalcapacityheating kW 22.4 28 33.6 39.2 44.8
cooling kW 20 25 30 35 40
Capacityrange HP 8 10 12 14 16
Dimensions HxWxD mm 1680x1300x765
Weight kg 331 339
Soundpowerlevel heating dB(A) 78 80 83 84
Soundpressurelevel heating C 58 60 62 63
Operationrangeheating C -20C~20*
domesticwater C -20C~35*
Refrigerant type kg R-410A
Powersupply 3~/50Hz/380-415V
Pipingconnections
liquid mm 9.52 12.7
suction mm 19.1 22.2 28.6
high&lowpressuregas 15.9 19.1 22.2
maxtotallength m 300
leveldiffernceOU-IU m 40
Recommendedfuses A 20 25 40
Heatingconditions:Ta=7CDB/6CWB,100%connectionratioCoolingconditions:Ta=35CDB,100%connectionratio*Capacitynotguaranteedbetween-20Cand-15C
1 Waterinlettemperature=45C/Wateroutlettemperature:40C indoortemperature=20CDB Mediumfanspeed2 Waterinlettemperature=7C/Wateroutlettemperature:12C indoortemperature=27CDB/19CWB Mediumfanspeed
ekhts200ac ekhts260acWatervolume l 200 260Max.watertemperature C 75CDimensions HxWxD mm 1,335x600x695 1,610x600x695Dimensions-integratedonindoorunit
HxWxD mm 2,010x600x695 2,285x600x695
Materialoutsidecasing galvanisedmetalColour MetallicgreyEmptyweight kg 70 78
hot water tank
ekhBrD011acV1 ekhBrD014acV1 ekhBrD016acV1 ekhBrD011acy1 ekhBrD014acy1 ekhBrD016acy1
Casing Colour MetallicgreyMaterial Precoatedsheetmetal
Dimensions Unit Height/Width/Depth mm 705/600/695Weight Unit kg 144.25 147.25Operationrange
Heating Ambient Min.~Max. C -20~20Waterside Min.~Max. C 25~80
Domestichotwater
Ambient Min.~Max. CDB -20~35Waterside Min.~Max. C 25~80
Refrigerant Type R-134aCharge kg 3.2
Soundpressurelevel
nom. dBA 43(5)46(6)
45(5)46(6)
46(5)46(6)
43(1)46(2)
45(1)46(2)
46(1)46(2)
nightquietmode
Level1 dBA40(5) 43(5) 45(5) 40(1) 43(1) 45(1)
Powersupply name V1 y1Phase 1~ 3~Frequency Hz 50Voltage V 220-240 380-415
Current Recommendedfuses A 25 16
(1)EW55C;LW65C;Dt10C;ambientconditions:7CDB/6CWB|(2)EW70C;LW80C;Dt10C;ambientconditions:7CDB/6CWB|(3)EW30
32
naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
Daikinproductsaredistributedby:
ThepresentleafletisdrawnupbywayofinformationonlyanddoesnotconstituteanofferbindinguponDaikinEuropen.V..DaikinEuropen.V.hascompiledthecontentofthisleaflettothebestofitsknowledge.noexpressor impliedwarranty isgivenfor thecompleteness,accuracy, reliabilityor fitness forparticularpurposeofitscontentandtheproductsandservicespresentedtherein.Specificationsaresubjecttochangewithoutpriornotice.DaikinEuropen.V.explicitlyrejectsany liability foranydirector indirectdamage, inthebroadest sense, arising fromor related to theuse and/or interpretationof this leaflet. All content iscopyrightedbyDaikinEuropen.V.
FSC
ECPEn12-727
Daikins unique position as a manufacturer of airconditioning equipment, compressors and refrigerantshasledtoitscloseinvolvementinenvironmentalissues.ForseveralyearsDaikinhashadtheintentiontobecomea leader in the provision of products that have limitedimpact on the environment. This challenge demandsthe eco design and development of a wide rangeof products and an energy management system,resulting in energy conservation and a reductionofwaste.
ECPE
n12
-727
10
0010
/11C
opyrightDaikin
Printedon
non
-chlorinated
pap
er.Prepa
redby
la mov
ida, Belgium
Re
sp.Ed.:D
aikinEu
rope
n.V.,Z
andv
oordestraat3
00,B-840
0Oostend
e