    GEEnergy

    Product OverviewGE Energys D400* substation data manager is a secure,

    substation-hardened gateway that collects metering, status,

    event, and fault report data from serial or LAN basedIntelligent Electronic Devices (IEDs). The D400 summarizes data

    from the IEDs and makes it available locally through a

    Keyboard-Video-Mouse (KVM) port or locally/remotely through

    a standard secure web browser (HTTPS). It supports serial

    and/or LAN connections to SCADA masters. TCP/IP network

    connections are supported over the built-in Ethernet and the

    modem interface.

    Benefits and Strengths Data concentration

    Ease of use/configuration Embedded substation HMI and alarming

    Non-operational data support

    Support for NERC CIP compliance

    Embedded security applications

    Legacy protocol support

    Expandable and upgradeable platform

    Features Secure web server (128 bit encryption)

    Secure access using SSH (Secure Shell)/SCP (Secure Copy)/HTTPS

    Secure terminal server, gateway, and/or data concentrator using

    Secure Sockets Layer or Transport Layer Security (SSL/TLS)

    User configurable security levels/access

    Support for remote user authentication

    Built-in alarm Annunciator

    Support for Network Time Protocol (NTP)

    Supports multiple SCADA protocols for communications

    to multiple masters

    Built-in basic math/logic functions

    Event notification (e-mail, pager)

    Memory stick support for historical logs

    Internal SQL database

    Dual hot swappable power supplies

    Secure Substation HMI/AnnunciatorThe D400 supports a web based HMI/Annunciator feature, that is

    accessible using a standard Internet browser or through a VGAmonitor and USB keyboard/mouse attached directly to the unit.

    Non-operational DataUsing pass-through connections, the utility user can extract

    valuable non-operational data such as digital fault recording (DFR)

    records and event files. The user can also access the historical log

    files and upload the archived data for trending and analysis.

    Hardware OverviewThe D400 is built on a flexible, high performance, expandable

    diskless and fanless platform that is powered by a 650 MHzprocessor. The D400 supports various communication media

    typesSerial: RS-232, RS-485, Glass Fiber, and Plastic Fiber; and

    Ethernet: 10/100Base-T, 10Base-FL, and 100Base-SX. Two

    Ethernet networks are supported with separate multiport switches.

    An IRIG-B format time protocol input/distribution module is also

    supported. Serial port media is selected for each pair of ports.

    D400* Substation Data Manager fact sheet

  • 8/4/2019 D400 Fact Sheet

    2/2

    Data ConcentrationThe D400 Substation Data Manager, when operating as a SCADA

    host, collects, filters and sorts data from a wide range of IEDsin the substation (RTUs, protection relays, meters). Data can be

    presented to multiple SCADA hosts.

    Time Sync SupportThe D400 has extensive support for various time sync method-

    ologies and will accept time sync signals from SNTP/NTP Servers,

    IRIG-B (un-modulated/modulated), and SCADA protocols. The

    D400 can also distribute this time sync information through its

    built-in NTP Server, IRIG-B distribution interface, SCADA protocols,

    and/or through the RS232 ports directly (SEL compatibility).

    Pass-through/Terminal ServerA built-in terminal server emulator allows pass-through connections

    to be initiated to any substation IED (relay, meter, RTU or other

    device). Once the connection is established, the local event

    records can be uploaded from the substation devices and viewed

    remotely. These connections can be secured using the D400s

    built-in TLS/SSL secure protocols.

    Network Diagram

    Embedded ProtocolsThe D400 comes with a built-in suite of protocols and security

    applications to facilitate communication with various substationIEDs and SCADA hosts#.

    #Please contact GE for protocol availability.

    Network/Security Protocols

    For more information, please visit ge.com/energy

    or email us at [email protected].

    * Trademarks of General Electric Company.Telegyr is a registered trademark of Landis+Gyr AGABB is a registered trademark of ABB Asea Brown Boveri Ltd.IEC is a registered trademark by Commission Electrotechnique Internationale.Modbus is a trademark of SCHNEIDER AUTOMATION INCSEL is as a registered trademark by Schweitzer Engineering Laboratories, Inc.NERC is as a registered trademark of North American Electric Reliability Council.

    2007, General Electric Company. All rights reserved.

    GEA-14302A (04/07)

    fact sheet

    DNP serial and TCP/IP

    (client and server)

    IEC 61850 (client)

    ModbusTM serial and TCP/IP

    (client and server)

    ABB Spabus

    Incom

    Beckwith with BECO2200

    April (RFL)

    DPU/TPU 2000

    GE modem

    Generic ASCII protocols

    SELFast Meter/SEL ASCII

    Hydran*

    LTC-Map*1525

    IEC60870-5-101/103/104

    HTTPS

    SSH/SCP

    DHCP

    NTP (client/server)