48
TIMBER DOWNTOWN Gro Krüger, Marte Guldvik og Ole Fredrik Kleivene

D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

TIMBERDOWNTOWNGro Krüger, Marte Guldvik og Ole Fredrik Kleivene

Page 2: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 3: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Superstructure in Dronning Mauds gate 10-11Infill in Skippergata 12Urban quarter at Sørenga

Page 4: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

URBAN QUARTERSØRENGA

New proposal for urban quarter at Sørenga.

Page 5: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 6: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 7: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

OUTDOOR SPACE

CONCEPT SIGHTLINES

LIGHT CONDITION

Page 8: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Space for commercial and common use

Site area: Area (BRA): Commercial: Duplex apartments: Other apartments:

100 apartments (55 m2 - 135 m2)

3 580 m2

14 300 m2

400 %

970 m2

1 030 m2

7 800 m2

Single-floor housing units

Two-storey housing units Parking, storage, staircases and spaces for maintenance

PROGRAM

Page 9: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 10: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 11: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

EXTERIOR WALL

Page 12: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 13: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 14: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

The courtyard. View towards Akershus Fortress to the left and Havnelageret to the right. Facades towards courtyard

Page 15: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 16: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

View from northeastern side of the block. Two storey housing units towards Sørengkaia.

CORNER BALCONIESHorisontal section through lower part of balcony railings, showing the switch of clinker-slips cladding to wood panel cladding. The transition happens with a sharp edge detail. Coloum and beam are customized and pre-cut.

WOOD PANELS

CLINKER-SLIPS

Page 17: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Two housing units. Workplace towards Sørengkaia, and a living area towards the courtyard.

LIGHT WALL

SECTION WALL

88 mm CLTWall placed below beam

310 mm

100 mm CLT100 mm insulation10 mm air gap100 mm CLT

Page 18: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 19: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Apartment overlooking the Akershus Fortress.

Page 20: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 21: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Base and staircase cores made out of concrete.

CLT floor slab and walls.

Glulam columns and beams.

Clinker slips and wooden cladding.

Page 22: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

THE INFILLSKIPPERGATA

New proposal for infill in Skippergata

Page 23: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 24: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

N S S 5 m0 m

S S

Page 25: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

assage t ro g t e lo k

Separate entran es for o er ial an o sing f n tions

ess to s nlit area an egetation pi al s i ision e isting oorplan

S S N S S

pi al s i ision new oorplaniews to t e e terior

Page 26: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

e ni al rooli

Sir lation

S are areas

Se i pri ateri ate

Page 27: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 28: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm
Page 29: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

WALL gipsplate

70 mm isolasjonfinerplate

air gap

parkett trinnl s atte

folie gra el sla

NS N gl la ea gl la ol n

NS N S N S N

N N

Page 30: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

N N

Page 31: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

S S

Closed Semi Open

Page 32: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

N N N

Page 33: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

S

Page 34: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

New Proposal for superstructures in Dronning Mauds gate

THE SUPERSTRUCTUREVIKA

Page 35: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Dronning Mauds gate

Løkkeveien

Munkeda

msveien

/ Ring

1

Ruseløkkve

ien

Victoria

Terras

se

Ruseløk

kveien

Situation Plan 0 5 10 20m

Page 36: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Elevation towards the fjord, Munkedamsveien0 5 10 20

m

Sketch model 1 Sketch model 2 Final suggestion Diagram showing how the buldings relate to the surrounding buildings

APPROACH

Page 37: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Existing situation seen from Akershus Fortress, August 2015

Dronning mauds gate 10 & 11Juni 1968 (www.oslobilder.no)

New proposal with sketch of the new National museum

Page 38: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Variation“One size do not fit all”

Existing building with closed offices around the perimeter

Air and vegetationDirect access to outdoor facilities

New proposal with open spaces and a lot of light and common space

Light

Page 39: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

North Facade Dronning Mauds gate 10

Longitudinal Section, Dronning Mauds gate 10

VENT

TEL/ELTEK

TEK

0 5 10 20

Page 40: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Longitudinal Section, Dronning Mauds gate 11

South Facade Dronning Mauds gate 11

VENT

0 5 10 20

Page 41: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

North- West Facades towards Ruseløkkveien ´

Page 42: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Illustration 3.Floor Dronning Mauds gate 11

Page 43: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

VENT

TEL/EL

TEK

TEK

VENT

lans oor Dronning Mauds gate 10 Dronning Mauds gate 110 21 5

m

Page 44: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

VENT

TEK

TEK

VENT

lans oor Dronning Mauds gate 10 Dronning Mauds gate 110 21 5

m

Page 45: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

VENT

lans oor Dronning Mauds gate 10 Dronning Mauds gate 110 21 5

m

Page 46: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

GSEducationalVersion

Filnavnprosjektet i 3D18.pln

RIVveien180000 RIVbyenTlf: 000 00 [email protected]

RIEveien180000 RIEbyenTlf: 000 00 [email protected]

Dato

Dato oppr.

Kontroll prosjekt.

Kontroll utførende

Prosjektnr. forprosjekterende/lev.

Sign.

Sign.

Godkjent

Kontroll

Kontroll

Målestokk

1:200

N

Rev Nr Beskrivelse Dato Sign Kontr

BIM-verktøy ArchiCAD 19 NOR Filplassering: /Users/grokruger/Documents/mockup-utstilling/lagrede filer onsdag 01/prosjektet i 3D18.pln

Revisjon nr.

Type tegningSalgstegninger

Tegningsnr.A71-101

Rådg. ing. Elektro

Fase

Status

Prosjekteringsgruppen

Rådg. ing. Bygg

Rådg. ing. VVSRIV :

Arkitektveien 190000 ArkitektbyenTlf.: 000 000 [email protected]

RIE :

ARK :

RIB : RIBveien180000 RIBbyenTlf: 000 00 [email protected]

Arkitektkontoret

Lokalisering:

Prosjektnr.:

Prosjektnr.

Tiltakshaver

TiltakshaverProsjekt

NorskProsjekteringsmal 19Adresse0000 Sted

Type tegning:

Salgstegninger

Tegningsnr.:

A71-101

Gnr./Bnr./Festenr.:

Gnr/Bnr/Festenr

VENT

VENT

STRUCTURAL PRINCIPLE

Page 47: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Illustration Lobby 1.Floor Dronning Mauds gate 10

Page 48: D2016 AUTUMN Marte Guldvik, Gro Kruger and Ole F Kleivene ... · GSEducationalVersion SECTION WALL 238 mm 100 mm cross-laminated timber (CLT) 100 mm insulation 10 mm air gap 100 mm

Superstructure in Dronning Mauds gate 10-11Infill in Skippergata 12Urban quarter at Sørenga