Scale:
Checked:
Design:
Drawn:
Update:
Redrawn:
Update Check:
Redesigned:City of Lake Oswego
Engineering Division
JBK
DB
JBKN.T.S.
KBK
Guy Graham, P.E. Public Works Director
City Engineer
Notes:
1) Concrete shall attain 4,000 p.s.i. compressionstrength in 28 days.
2) Contraction joints shall be constructed at allpoints of curvature and at a maximum intervals of20 feet.
3) This curb design is limited to use in cul-de-sac orother special circumstances specifically approved bythe City Engineer.
23"
112"
15" 8"
R=
1"
R= 1
2 "
R = 1
"
See
Det
ail S1-0
2
R=
1"
412" R=
1 4"
1"51
2"
12"
min
.
6" min.
6"
min
.
6"
112"- 0" compacted
crushed base rock
12"1"
MOUNTABLE CURBDETAIL
Scale:
Date:
Checked:
Design:
Drawn:
Update:
Redrawn:
Date/Update:
Update Check:
Redesigned:City of Lake Oswego
Engineering Division
MS
DB
MS
N.T.S.6/19/98 4/12/13
KBK
Guy Graham, P.E. Public Works Director
City Engineer
DKDRAWING NUMBER: W5-03
THRUST BLOCKING DETAILS
Each area is 12" oftabulated total area.
TEE PLUGGED CROSS WYE
PLUG OR CAP(STRADDLEBLOCK PER
DETAIL)
PLUGGED CROSS TEEBEND
Notes:1) Concrete thrust blocking to be poured against undisturbed earth. 2) Keep concrete clear of jointand accessories. 3) If not shown on plans, required bearing areas at fitting shall be as indicatedbelow, adjusted if necessary, to conform to the test procedure (S) and allowable soil bearing stress(ES) stated the special specifications. 4) Bearing areas and special blocking details shown on planstake precedence over bearing areas and blocking details shown on this standard detail. 5) Buildingpaper or visquine shall be placed between concrete and fittings. 6) All poured in place concrete shallhave a (28) day strength of 3,000 p.s.i. and 2" to 4" slump. 7) Below bearing areas based on testprocedure of 150 p.s.i. and an allowable soil bearing stress of 2,000 pounds per square foot. Tocompute bearing areas for different test pressures and soil bearing stresses, use the followingequation: bearing area = (test pressure/150) X (2,000/soil bearing stress) X (table value). Bearingareas in square feet.
FITTINGSIZE (IN.)
TEE, WYE,PLUG ORCAP
90° BENDPLUGGEDCROSS
TEE PLUGGEDON RUN 45°
BEND22 1/2°BEND
11 1/4°BEND
1.0
A
46810121416182024
1.02.03.85.98.5
11.515.019.023.534.0
1.43.05.38.412.016.321.327.033.348.0
1.94.37.611.817.023.030.038.047.068.0
1.43.05.48.4
12.016.321.327.033.348.0
1.62.94.66.68.9
11.614.618.126.2
-1.01.52.43.44.66.07.69.4
13.6
--
1.01.21.72.33.03.84.76.8
1 A2
A 1
A2
Finished grade
Valve box to be concreteencased if not in pavedarea. Min. fc' = 2,500 p.s.i.
18" Min.
6" class 200 or 6" C-900,DR-25, white
Cast iron valve box,"Vancouver" style, Model
No. 910 or equal
Water mainWater main
Align valvebox notcheswith directionof main
"VANCOUVER" VALVE BOX OR EQUAL
Notes:
1) Valve boxes shall be centered directly overthe valve nut in a vertical position.
2) Valve box top shall be adjusted to meetfinished grade.
12"8"
658"
3"
1'-6"
Scale:
Date:
Checked:
Design:
Drawn:
Update:
Redrawn:
Date/Update:
Update Check:
Redesigned:City of Lake Oswego
Engineering Division
Guy Graham, P.E. Public Works Director
City Engineer DRAWING NUMBER: W6-01
TYPICAL VALVE BOX
DB
MS
MS
N.T.S.
3/19/98 4/16/13
DK
KBK
DRAWING NUMBER: S2-03Scale:
Date:
Checked:
Design:
Drawn:
Update:
Redrawn:
Date/Update:
Update Check:
Redesigned:City of Lake Oswego
Engineering Division
RC/JBK
DB
JBKN.T.S.
4-25-05 9/25/12
KBK
Guy Graham, P.E. Public Works Director
City Engineer
DKDRAWING NUMBER: S2-01
Notes:
1) Knife joints shall be placed at all changes of direction and points of curvature and at amaximum spacing of 20 feet.2) Concrete used for curb shall meet a 4,000 P.S.I. Compression strength in 28 days.3) 3" plastic pipe shall have a bell or a 3" extension, for future hook-up.
6"
3"
9"
Street surface
A.C.
Levelingcourse(1"-0"crushedbaserock)
(1-1/2"- 0"CRUSHEDBASE ROCK)
6"
10"
16"
6"
6"
of cr
ush
ed &
com
pac
ted r
ock
VERTICAL CURB DETAIL
3" plastic pipe,generally not lessthan 2 per lot. Cut tomatch face of curb
R=1"R = 1
2"
H:\City Logo\CityofLO_Seal_Greyscale3.jpg