DL-S15A-250 STRAND JACK ( 1 : 10 ) PLAN VIEW ( 1 : 5 ) (SHOWING OUTSIDE DIMENSIONS) A ( 1 : 10 ) VIEW FROM BELOW ( 1 : 5 ) A Project Eng: Checking Eng: Description Drawing No. Project Design Eng: Drawn by: Drawing Title Rev Date Status Rev. By Copyright c Dorman Long Technology DO NOT SCALE NOTES Scales (At A3) This drawing has been produced by Dorman Long Technology in accordance with the instructions of the client for their sole and specific use. Dorman Long Technology shall not be liable for the use of any information contained on this drawing for any purpose other than that for which it was specifically prepared and provided. Should there be any doubt regarding the interpretation of any information given on this drawing, enquiries should be directed to Dorman Long Technology at the address given below before executing such part of the works. Drawing Status Original Drawing size: A3 Dorman Long Technology The Charles Parker Building Midland Road, Higham Ferrers Northamptonshire, NN10 8DN United Kingdom Tel: +44 (0) 1933 319133 Fax: +44 (0) 1933 319135 www.dormanlong.com C:\VaultWorkspace\Designs\INV_LIB\LIFTING_JACKS\DLT\STRAND\DL-S015-250 AS BUILT\DL-S15A-250-COMPLETE.iam DL-S15A-250 STRAND JACK GENERAL ARRANGMENT OF JACK MW SG TD MW AS BUILT DL-S15A-250-001-000 D 1 5 6 9 N O M I N A L C L O S E D L E N G T H JACK SPECIFICATION No. OF 18mm STRANDS SAFE WORKING LOAD WORKING PRESSURE JACK TEST LOAD (1.25 x SWL) MAIN CYLINDER TEST PRESSURE ON EXTEND AND RETRACT (1.5 x WORKING PRESSURE) CLOSED HEIGHT STROKE JACK WEIGHT STRAND CABLE O.D. 1 15.4 Te 210 BAR 19.3 Te 315 BAR 1579mm 250mm 117kg 18mm 220x160x30 BASE PLATE WITH 4 No. Ø19 HOLES FOR M16 FIXING BOLTS 3 0 TOP ANCHOR ASSEMBLY DRG DL-S15A-250-012 BOTTOM ANCHOR ASSEMBLY DRG DL-S15A-250-011 ANTI-ROTATION GUIDE DRG DL-S15A-250-051 A 27.10.06 CON ISSUED FOR CONSTRUCTION SG 6 0 6 0 80 80 2 5 0 S T R O K E MAIN CYLINDER DRG DL-S15A-250-061 B 21.11.07 ASB AS BUILT UPDATE TJB C 23.09.08 ASB HYDRAULIC FITTINGS ADDED AW APPROX 240 A P P R O X 3 0 0 TOP ANCHOR ASSEMBLY DRG DL-S15A-250-012 MAIN CYLINDER DRG DL-S15A-250-061 BOTTOM ANCHOR ASSEMBLY DRG DL-S15A-250-011 DL-S15A FIXED ANCHOR (1:4) 1 4 0 1 0 0 70 D 05.01.09 ASB MINOR REVISIONS SG

D05.01.09ASBMINOR REVISIONS SG … · The Charles Parker Building Midland Road, Higham Ferrers Northamptonshire, NN10 8DN United Kingdom Tel: +44 (0) 1933 319133 Fax: +44 (0) 1933

  • Upload
    ngonhi

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

DL-S15A-250 STRAND JACK ( 1 : 10 )

PLAN VIEW ( 1 : 5 )(SHOWING OUTSIDE DIMENSIONS)

A ( 1 : 10 )

VIEW FROM BELOW ( 1 : 5 )

A

Project Eng:

Checking Eng:

Description

Drawing No.

Project

Design Eng:

Drawn by:

Drawing Title

Rev Date Status

Rev.

By

Copyright c Dorman Long Technology

DO NOT SCALE

NOTES

Scales(At A3)

This drawing has been produced by Dorman Long Technology in accordance with the instructions of the client for their sole and specific use.

Dorman Long Technology shall not be liable for the use of any informationcontained on this drawing for any purpose other than that for which it was specifically prepared and provided.

Should there be any doubt regarding the interpretation of any information given on this drawing, enquiries should be directed to Dorman Long Technology at the address given below before executing such part of the works.

Drawing Status

Original Drawing size: A3

Dorman Long TechnologyThe Charles Parker Building

Midland Road, Higham FerrersNorthamptonshire, NN10 8DN

United KingdomTel: +44 (0) 1933 319133Fax: +44 (0) 1933 319135

www.dormanlong.com

C:\VaultWorkspace\Designs\INV_LIB\LIFTING_JACKS\DLT\STRAND\DL-S015-250 AS BUILT\DL-S15A-250-COMPLETE.iam

DL-S15A-250 STRAND JACK

GENERAL ARRANGMENT OF JACK

MW

SG

TD

MW

AS BUILT

DL-S15A-250-001-000 D

1569

NO

MIN

AL

CLO

SE

D L

EN

GT

H

JACK SPECIFICATION

No. OF 18mm STRANDS

SAFE WORKING LOAD

WORKING PRESSURE

JACK TEST LOAD (1.25 x SWL)

MAIN CYLINDER TEST PRESSUREON EXTEND AND RETRACT(1.5 x WORKING PRESSURE)

CLOSED HEIGHT

STROKE

JACK WEIGHT

STRAND CABLE O.D.

1

15.4 Te

210 BAR

19.3 Te

315 BAR

1579mm

250mm

117kg

18mm

220x160x30 BASE PLATE WITH4 No. Ø19 HOLES FORM16 FIXING BOLTS

30

TOP ANCHORASSEMBLYDRG DL-S15A-250-012

BOTTOM ANCHORASSEMBLYDRG DL-S15A-250-011

ANTI-ROTATION GUIDEDRG DL-S15A-250-051

A 27.10.06 CON ISSUED FOR CONSTRUCTION SG

6060

80 8025

0 S

TR

OK

E

MAIN CYLINDERDRG DL-S15A-250-061

B 21.11.07 ASB AS BUILT UPDATE TJBC 23.09.08 ASB HYDRAULIC FITTINGS ADDED AW

APPROX 240

AP

PR

OX

300

TOP ANCHORASSEMBLYDRG DL-S15A-250-012

MAIN CYLINDERDRG DL-S15A-250-061

BOTTOM ANCHORASSEMBLYDRG DL-S15A-250-011

DL-S15A FIXED ANCHOR(1:4)

14010

0

70

D 05.01.09 ASB MINOR REVISIONS SG

DL-S60 JACK(DRG DL-S60-011)

( 1 : 10 )

TOP PLAN ON A

( 1 : 10 )

BOTTOM PLAN ON B

( 1 : 10 )

DL-S60 FIXED ANCHOR(DRG DL-S60-101)

( 1 :5 ) Project Eng:

Checking Eng:

Description

Drawing No.

Project

Design Eng:

Drawn by:

Drawing Title

Rev Date Status

Rev.

By

Copyright c Dorman Long Technology

DO NOT SCALE

NOTES

Scales(At A3)

Sheet

This drawing has been produced by Dorman Long Technology in accordance with the instructions of the client for their sole and specific use.

Dorman Long Technology shall not be liable for the use of any informationcontained on this drawing for any purpose other than that for which it was specifically prepared and provided.

Should there be any doubt regarding the interpretation of any information given on this drawing, enquiries should be directed to Dorman Long Technology at the address given below before executing such part of the works.

Drawing Status

Original Drawing size: A3

Dorman Long TechnologyThe Charles Parker Building

Midland Road, Higham FerrersNorthamptonshire, NN10 8DN

United KingdomTel: +44 (0) 1933 319133Fax: +44 (0) 1933 319135

www.dormanlong.com

ofC:\VaultWorkspace\Designs\INV_LIB\LIFTING_JACKS\DLT\STRAND\DL-S060-AS BUILT\DL-S060 - Jack & Fixed Anchors\DL-S60-COMPLETE.iam

DL-S60 STRAND JACK

STRAND JACK AND FIXED ANCHOR

DJD

SCC

MW

DJD

AS BUILT

DL-S60-001-000 D1 1

AS SHOWN

GENERAL ARRANGEMENT

A

B

1995

NO

MIN

AL

O/A

CLO

SE

D L

EN

GT

H500 O/A APPROX

429

O/A

JA

CK

ING

FR

AM

E33

0

200

150

200

150

330x330x50 THK BASE PLATETO JACK WITH 4 No Ø26 HOLESFOR M24 FIXING BOLTS

200x200x80 THK BASE PLATETO FIXED ANCHOR WITH 4 NoØ22 HOLES FOR M20 FIXING BOLTS

JACK SPECIFICATION

No. OF 18mm STRANDS

SAFE WORKING LOAD

WORKING PRESSURE

125% TEST PRESSURE

CLOSED HEIGHT

STROKE

JACK WEIGHT

FIXED ANCHOR WEIGHT

STRAND CABLE O.D.

4

62 Te

200 BAR

250 BAR

1995mm

500mm

500kg

29kg

90mm

500

ST

RO

KE

70

A 29.11.06 CON ISSUED FOR CONSTRUCTION SG80

80

B 14.11.07 CON AS BUILT AW

TOP ANCHORASSEMBLYDRG DL-S60-014

MAIN CYLINDERDRG DL-S60-061

BOTTOM ANCHOR ASSEMBLYDRG DL-S60-012

JACK FRAMEDRG DL-S60-81

C 07.07.08 CON FA FIXING HOLES AMENDED JK

260

260

330

70

D 18.09.08 CON CYLINDER BLOCK ADDED AW

30

DL-S185 JACK (DRG DL-S185-011-000) ( 1 : 10 )

PLAN VIEW ( 1 : 10 )

FIXED ANCHOR TYPE 1

(DRG DL-S185-101-000)

Project Eng:

Checking Eng:

Description

Drawing No.

Project

Design Eng:

Drawn by:

Drawing Title

Rev Date Status

Rev.

By

Copyright c Dorman Long Technology

DO NOT SCALE

NOTES

Scales(At A3)

Sheet

This drawing has been produced by Dorman Long Technology in accordance with the instructions of the client for their sole and specific use.

Dorman Long Technology shall not be liable for the use of any informationcontained on this drawing for any purpose other than that for which it was specifically prepared and provided.

Should there be any doubt regarding the interpretation of any information given on this drawing, enquiries should be directed to Dorman Long Technology at the address given below before executing such part of the works.

Drawing Status

Original Drawing size: A3

Dorman Long TechnologyThe Charles Parker Building

Midland Road, Higham FerrersNorthamptonshire, NN10 8DN

United KingdomTel: +44 (0) 1933 319133Fax: +44 (0) 1933 319135

www.dormanlongtechnology.com

C:\VaultWorkspace\Designs\INV_LIB\LIFTING_JACKS\DLT\STRAND\DL-S185\AS BUILT\DL-S185 Jack & Fixed Anchor\DL-S185_000 - Jack & Fixed Anchor\DL-S-185 CO

DL-S185 STRAND JACK

STRAND JACK AND FIXED ANCHOR

AW

MW

MW

AS BUILT

DL-S185-001-000 A

1:10

GENERAL ARRANGEMENT

190

235

190

235

19023

5

190

235

470x470x50 THKBASE PLATE TO JACKWITH 4 No. Ø26 HOLESFOR M24 FIXING BOLTS

290

340

340

290

56

210

148

SPECIFICATION

No. OF 18mm STRANDS

SAFE WORKING LOAD

WORKING PRESSURE

125% TEST PRESSURE

CLOSED HEIGHT

STROKE

JACK WEIGHT

FIXED ANCHOR WEIGHT(TYPE 1)

FIXED ANCHOR WEIGHT(TYPE 2)

STRAND CABLE O.D.

12

185 TONNES

294 BAR

370 BAR

2100mm

500mm

1500kg

150kg

135kg

166mm340x340x130 THKBASE PLATE WITH4 No. Ø26 HOLESFOR M24 FIXING BOLTS

A 31.05.07 CON AS BUILT AW

BOTTOM ANCHOR ASSEMBLYDL-S185-012-000

MAIN CYLINDERDL-S185-061-000

TOP ANCHORASSEMBLYDL-S185-014-000

148 (9 STRANDS)

56 (3 STRANDS)

TOP ANCHOR ASSEMBLYDL-S185-014-000

MAIN CYLINDERDL-S185-061-000

BOTTOM ANCHORASSEMBLYDL-S185-012-000

660

50

2130

500

ST

RO

KE

660

700

AP

PR

OX

DL-S418 JACK (DRG DL-S418-011)

A ( 1 : 10 )

FIXED ANCHOR (DRG DL-S418-101)

Project Eng:

Checking Eng:

Description

Drawing No.

Project

Design Eng:

Drawn by:

Drawing Title

Rev Date Status

Rev.

By

Copyright c Dorman Long Technology Limited.

DO NOT SCALE

NOTES

Scales(At A3)

Sheet

This drawing has been produced by Dorman Long Technology Limited in accordance with the instructions of the client for their sole and specific use. Dorman Long Technology Limited shall not be liable for the use of any information contained on this drawing for any purpose other than that for which it was specifically prepared and provided. Should there be any doubt regarding the interpretation of any information given on this drawing, enquiries should be directed to Dorman Long Technology Limited at the address given below before executing such part of the works.

Drawing Status

Original Drawing size: A3

Dorman Long Technology LimitedUK Southern Office:

The Charles Parker BuildingMidland Road, Higham FerrersNorthamptonshire, NN10 8DN

United KingdomTel: +44 (0) 1933 319133

Fax: +44 (0) 1933 319135www.dormanlongtechnology.com

of

A 30.04.06 CON ISSUED FOR CONSTRUCTION SG

L:\Acad_lib\Lifting-Jacks\DLT\Inventor\DL-S418\Fabrication\DL-S418-COMPLETE.iam

DL-S418 STRAND JACK

STRAND JACK AND FIXED ANCHOR

MWSG

TDMW

FOR CONSTRUCTION

DL-S418-001 A1 1

AS SHOWN

GENERAL ARRANGMENT

A

2210

500

STR

OK

E

670

450

670

450

600

600

430 430

380

450

450

380

n240 (15 STRANDS)

n148 (9 STRANDS)

n56 (3 STRANDS)

249

SPECIFICATION No. OF 18mm STRANDS SAFE WORKING LOAD WORKING PRESSURE 125% TEST PRESSURE CLOSED HEIGHT STROKE JACK WEIGHT FIXED ANCHOR WEIGHT STRAND CABLE O.D.

27 418 TONNES 318 BAR 400 BAR 2190mm 500mm 3500kg 300kg 258mm

n148 (9 STRANDS)

n56 (3 STRANDS)

n240 (15 STRANDS)

50

670x670x50 BASE PLATEWITH 8 No. Ø28 HOLESFOR M24 FIXING HOLES

450x450x100 BASE PLATEWITH 4 No. Ø26 HOLESFOR M24 FIXINGS