19
Read instruction manual thoroughly before using product. Product appearance, specification etc. is subject to change without prior notice if necessary for improving product performance. Design and color may differ from cover model. The rated voltage of this product is 220-230V/50Hz only. Deluxe· Humidification· Air cleaning http://eng.chungho.co.kr User's Manual

D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

▶ Read instruction manual thoroughly before using product.▶ Product appearance, specification etc. is subject to change without prior notice if necessary for improving product performance.

▶ Design and color may differ from cover model.▶ The rated voltage of this product is 220-230V/50Hz only.

Deluxe· Humidification· Air cleaning

http://eng.chungho.co.kr

User's Manual

Page 2: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

1. Product features 3

2. Safety precautions 4~7

3. Name of each part 8

4. Operation and display function 9

5. Filter function 10

6. Usage of each button 11~ 13

6-1. Power button 11

6-2. Speed button 11

6-3. Timer button 11

6-4. How to use humidification function 12

6-5. ACI Button 12

6-6. Sleep button 12

6-7. Particle Sensor (Sensitivity control) 13

7. Maintenance and replacement 14~17

7-1. Filter cleaning and replacement 14

7-2. Filter rservice life 14

7-3. Water tank cleaning 15

7-4. Disc tank cleaning 16

7-5. Particle sensor cleaning 17

8. Troubleshooting 18

9. Specification 19

We greatly appreciate your purchase of ChungHo Nais air purification system “IGUASSU D·H·A”.IGUASSU D·H·A is designed and programmed in accordance with industrial standards. Applied 4 stages of filter system (Pre-filter, Antibiotic filter, HEPA filter and Deodorization filter) make it possible to removefine dust as small as 0.3㎛, formaldehyde and volatile organic compound which are one of the causes ofSick House Syndrome and ammonia, acetaldehyde etc. Antibiotic filter includes extract from ginkgo leaves.It refrains mold and germ from increasing. Released Cluster Ion helps to eliminate germs and virus moreeffectively. Natural humidifying method using rotating disc makes the indoor optical humidity.

Please read the instruction manual thoroughly and keep it for a future reference.

Greetings

Table of Contents

Page 3: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

2

1

3

4

5

6

7

8

IG

UA

SS

UD·

A

03

1. Product features

9

Innovative hybrid productIGUASSU D·H·A is an innovative hybrid product, which is combined with air purifier andhumidifier. Air purifier eliminates pollutant in the air and humidifier helps to keep the humidityat the ideal level.

Pure and natural humidification system Purified air filtered by filtering unit contacts wet surface of rotating disc to maintain pleasanthumidity level.

Active Cluster lon generatorActive cluster lon- ACL(Active Cluster Lon)generator releases and to the air and theyare combined with moisture to form cluster ion. It sticks to harmful substances including germ,virus etc and creates oxidative OH radical to destroy pollutant.

Superior air cleaning capacity4 stages air cleaning system equipped with Pre filter, Antibiotic filter, HEPA filter andDeodorization filter eliminates fine dust and odor substances and it inhibits microbial growthsuch as mold, germ and bacteria.

Auto operation by detecting the pollution levelIt displays the indoor air pollution level detected by particle sensor and enable user to knowpollution level easily and “Auto” mode controls the airflow speed automatically in accordancewith the air pollution level and conveniently keep pleasant air in the room.

ConvenienceThis is equipped with drawer-type water container and it is very easy to pull out.

Safety functionWhile the unit is working, when disc tank is separated from the body then purifying motorstops working to prevent the accident.

Alarm functionDisplay of Indoor air pollution level detected by particle sensor, no water indicator, alarmingwhen the humidity reaches to the set humidity level etc make easy to control.

Sleek and slim design Sleek and slim design along with convenience matches well in any place.

Page 4: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

04

2. Safety precautions

Associated with the possibility for serious injury or death.Danger

● Keep the power cord pin clean from dustand water.(An electric shock offire may occur.)

● Use the designated power rating. (Inappropriate voltage may cause a fire orelectric shock as well as product failure.)

● Put the cord all the way to the end.(Unstable connection may cause fire.)

● Keep the cord out of heavy traffic areas.(This can lead overheating to outlet.)

● If the power cord is damaged or pin of power plug is loose, request follow-up service.(An electric shock and fire may occur.)

● To disconnect the unit, be sure to pull by the plug and not the cord.(Damaged power cord cancause a fire and electric shock.)

● Be careful not to step on and fall over the cord. (There is a danger of injury or an electric shock.)

● Do not touch the power plug with wet hands.(An electric shock may occur.)

Cautions are divided into 2 categories: 'Danger' and 'Caution.'

Page 5: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

IG

UA

SS

UD·

A

05

2. Safety precautions

Associated with the possibility for serious injury or death.Danger

● Do not bend the power cord excessively nor allow it to be damaged by being pressedunder heavy objects.(An electric shock may occur. )

● Do not place heavy object on the product and give a shock on it.(Damaged product may cause overheating and fire.)(If the product is mal-functioning, requestfollow-up service.)

● Stop using in the event of abnormal sound orsmell.(Earthquake, fire andflood or abnormal sound or smell is found, stop using theproduct and unplugthe power cord.)

● Do not drink water of water tank. Keep youreyes on kids.(This may be harmful to the health.)

● If the product falls down, unplug and requestfollow-up service.(This cause fire, electric shock and malfunction.)

● Do not install the product nearby largely flammable materials(Spray, butane, etc).Do not sprinkle hair spray or insecticide overthe product.(An explosion and fire may occur.)

● Do not allow you to expose cool air directly for long period of time. (Body temperature may fall.)

● If the product is damaged or malfunctioning, do not disassemble, repair, or modify it on your own.(An electric shock or fire may occur.In case the product is damaged, request follow-up service.)

Page 6: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

06

2. Safety precautions

Associated with the possibility for serious injury or death.Danger

● Do not place the product in damp place or at the place exposed to rain or snow.(A fire or electric shock may occur.)

● Do not put your hand into the product while replacing filter.(Malfunction and electric shock can be followed.)

Associated with injury, property damage, and performance degradation.Caution

● Do not install the production in a sloped or unstable position.(If the unit falls down, water can overflow.)

● This product is for indoor usage only.● Do not expose this product under direct sunlight.(If not, it can cause deformation and discoloration. )

● Do not use the product at a place such as kitchen, restaurant, construction site etc. which can be filled with oil, dust, poisonous gas etc.(Shortened service life of filter and less air purifying efficiency may occur.)(Malfunction can occur by sensor contamination.)

● This is for purifying air indoor only.(Other purpose than this includinguse as a ventilation system canbring out shortened service life of filter and less air purifying efficiency.)

● Do not put foreign substance such as pin, coin etc. into air inlet or outlet. Especially, do not allow kids to insert object inside.(Damage of the product and electric shock can be followed.)

● Do not block air inlet and outlet with laundry or curtain(Blocking ventilation holes may rise inside temperatures and it can cause a fire.)

Page 7: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

IG

UA

SS

UD·

A

07

2. Safety precautions

Associated with injury, property damage, and performance degradation.Caution

● Do not allow kids to hang on or climb on the product.(Injury may occur.)

● Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40。C). And clean up the water tank and disc tank. (Recommendation : everyday/ twice a week at least)(Hot water can cause the damageor water leakage of product.)(Refer to page 15~16 regarding cleaning.)

● Empty the water tank and disc tank in case humidi-fication is not used for a long time or there is possibility of freeze.(If you keep the water stagnant in the water tank or disc tank for long periods of time, germ and bacteria may breed inside and it can cause odor.)(After cleaning up the tanks, dry them in the shade.)

● Do not give the external shock to the water tank.It can cause the damage of product.(The external shock is the reason of the waterleakage.)

● Do not forget to empty the water tank and disc tank before transportation.(Water leakage can occur.)

● Do not move the product while in operation. (Malfunction and fire may occur.)

● Before you clean up the product or replace filter, unplug and wait until the product stops working. (Damage of product and electricshock may occur.)

● Use the product according to guideline in user’s manual. (If the product is not used in accordance with introduction in the manual, it can cause injury and electric shock.)

Page 8: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

08

3. Names of each part

Air Inlet

Air Inlet

Air Inlet

Air Outlet

Handle

Display and Controller

Pollution Level Display Particle Sensor/Humidification SensorCover

Water Level Display

Disc Tank Rotating Disc

Water Tank

Side Cover

Page 9: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

Sleep : Sleep Mode setting

ACI : ACI (Active Cluster Ion) On/Off

No Water : Lack of water indicator

Power : Power On/Off

Speed setting : Fan Speed level Indicator

Humidity setting : Humidity Level Indicator

Timer setting : Time indicator

Speed : Speed level setting

Humidity : Humidity level setting

Timer : Time setting

Pollution level display lamp : Display of indoor

dust level

3

1

2

10

7

4

5

9

6

1

2

3

4

5

6

7

8

9

10

11

IG

UA

SS

UD·

A

09

4. Operation and display function

8

11

Page 10: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

10

5. Filter function

Side cover

Pre-filter

HEPA filter

Deodorization filter

Antibiotic filter

Pre-filter Eliminate visible particles to the eye such as dust, lint and pet hair.

Antibiotic filter Consisted of antibiotic substance against antibacterial, mold etc and removestick, yellow dust.

HEPA filter

Deodorization filter

Eliminate fine particles as small as 0.3 ㎛ such as bacteria and dust of the potentialcauses of respiratory problems.

ACI (Active Cluster Ion)

Release Cluster Ion to effectively help to eliminate germs and virus.

Made from activated carbon well known for powerful function removesETS, VOCS, ammonia and various gases etc.

Page 11: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

※Plug in the power before using the product.※Initially, product is programmed to operate at level 1.

Display

Speed Level

Pollution Level Blue Green / Purple Red

Level 1 Level 2 Level 3

① Setting of ON/OFF- Press the button to turn on.- When connecting to power supply, it operates at level 1.- Press the button for about 2 seconds to turn off.

① Press ‘SPEED’ button•As you press ‘Speed’ button, Speed is switched as follows "Level 1 → Level 2 → Level 3 → Turbo → Auto → Level 1".

② Auto setting •Set auto mode by pressing ‘SPEED’ button. •In the auto mode, depending on level of particle contamination, fan speed is switched as follows"Level 1 → Level 2 → Level 3".

IG

UA

SS

UD·

A

11

6. Usage of each button

6-1 Power button

6-2 Speed button

Display

Continuation 2 hrs 4 hrs

① Timer button•Initial setting is programmed for .

② Press ‘Timer’ button•As you press ‘Timer’ button, timer is switched as follows, “ → 2hrs → 4hrs → 8hrs → ”.

6-3 Timer button

8 hrs

Page 12: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

12

6. Usage of each button

① Pour the water into the water tank.•Pull the water tank handle on the front.•Detach the cap beneath of water tank by turning the cap in reverse.•After pouring the tap water or purified water and put the cap back.

※ When filling the tank with water or transporting water tank, be aware not to givea shock to water tank. Damage may cause leakage of water.

※ Do not use hot water temperatures of over 104˚F (40 ˚C). Hot water may cause damage and defect.

② Insert water tank into the body.•Initially, insert the lower part of water tank and then the upper part to the body.•If water tank or disc tank are not placed completely, it can cause the leakage of water and malfunctioning.

③ Set the humidity.•As you press “Humidity” button, humidity is switched as follows. “ → 60% → 50%→ 40% → ”.

•Air purification with humidification works when ‘Humidity’ is turned on. ※ While air purification with humidification is working, set humidity level is reached, “Humidity” is blinking and rotating disc stops working.

※ Humidification rate varies depending on indoor temperature and humidity.

6-4 How to use humidification function

•If sleep mode is set, pollution level display is turned off and speed isset at level 1 not to interrupt sleep.

6-5 ACI button

※ While ‘Sleep’ is on, ‘Speed’, ‘Humidity’, ‘Timer’, ‘ACI’ can be adjusted. ※ Press ‘Sleep’ button, ‘Sleep’ is released and level 1 is set while other setting stay same.

6-6 Sleep button

•Active Cluster Ion - ACI (Active Cluster Ion) generator releases cluster ion to the air to destroy germ and virus.

•ACI display is turned on if the ACI button is pressed.

Page 13: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

DullH igh dull Standard Sensitive High sensitive

IG

UA

SS

UD·

A

13

6. Usage of each button

• The product is set standard level of sensitivity. If the product operates in red color for more than 2 hours even not in high humidity and yellow dust or if the product operates in blue color for more than 1 hour even in high pollution, particle sensor is needed to clean. (please refer to the page 17.) If the cleaning is no use, control the sensitivity of particle sensor as below.

① While the product is in operation, press ‘Speed’ and ‘Humidity’ for 2 seconds, particle sensor gets vitalized ringing beep sound. (setting sound: ding ding ding).

② Standard speed is set at level 2.

③While particle sensor get vitalized as you press ‘Humidity’, the sensor gets dull,

and as you press ‘Speed’, the sensor gets sensitive.

④ If the setting is set and press ‘Speed’ and ‘Humidity’ for 2 seconds, sensitivity is set and then function is released but if no button is applied for 10 seconds, the function is automatically released as sensitivity is set.

6-7 Particle sensor (Sensitivity Control)

Display

Level

Page 14: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

14

7. Maintenance and Replacement

7-1 Filter cleaning and replacement

7-2 Filter service life

① Turn off and unplug the unit.• If not, electric shock may occur.

③ Pull out forward the pre filter as pulling two holders.• Pre filter needs cleansing work with vacuum cleaner or water once a month.

④ Detach antibiotic filter, HEPA filter and deodor-ization filter from the main body.

⑦ Insert pre filter to square-shaped hole (Top and bottom) and to sides (left and right) properly.

⑧ Insert front cover and plug the power.

② Pull out the side cover as holding the side of the product.

⑤ Replace filters which are over service life period with new ones.

⑥ Put the filters into the filter case in a reverse order. (Front cover – pre filter – antibiotic filter – HEPA filter- deodorization filter)※ Refer to the page 10

Square–shaped hole

※ Service life and period of cleaning can be different depending on circumstances.

Filter Service life & Cleaning

Pre filter 1 month

Antibiotic filter 2 months

HEPA filter 12 months

Deodorization filter 6 months

Process

Reuse after cleaning

Change

Change

Change

Page 15: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

•Clean the water tank. (Recommendation : Everyday/ twice a week at least.)

IG

UA

SS

UD·

A

15

7. Maintenance and Replacement

7-3 Water tank cleaning

① As you press the power button for 2 seconds, turn off the power.② Detach water tank from the body and throw away water.

③ Pour water into the tank up to 1/3 and put the cap back. Shake it with both hands to clean it up.

※ In case the water tank is very contaminated, adjust 1~2 drops of

a neutral detergent. After cleaning it with a neutral detergent,

don’t forget to wash it out completely.

※While cleaning water tank, be careful not to drop it. Damage

may cause water leakage.

※While cleaning, don’t use hot water, it can cause deformation

and damage.

④ When cleaning water tank, be sure to use clean water.

※ In case you won’t use humidification function for a long time,

be sure to dry it up in the shade after cleansing and assemble it.

Page 16: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

16

7. Maintenance and Replacement

7-4 Disc tank cleaning

•Clean up the disc tank. (Recommendation : Everyday/ twice a week at least.)

① As you press the power button for 2 seconds,turn off the power.

② Detach water tank from the body and pull out the disc tank.

③ Detach partition from the disc tank and clean it up.

④ Detach rotating disc and clean it up in runningwater with soft cloth or brush as applying

neutral detergent.

※While cleaning, don’t use hot water,

it can cause deformation and damage.

※ Do not dissemble the rotating disc.

⑤ Clean up the disc tank with soft cloth or brush as applying neutral detergent.

※ Lift float-type water level sensor slightly

and clean up with cleaning brush.

⑥ Reassemble and use it.※ In case you don’t use humidification

function for a long time, be sure to clean

up water tank and disc tank and dry them

in the shade.

Page 17: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

7. Maintenance and Replacement

IG

UA

SS

UD·

A

17

7. Maintenance and Replacement

•Particle sensor is…Particle sensor detects fine dust going around from carpet, cigarette smoke and blanket etc. and sendsignal to the controller to indicate how polluted indoor air is. Pollution level is displayed by lamp color.

※ Cleaning work is recommended every month.

7-5 Particle sensor cleaning

① Plug out the power.※ Do not touch with wet hands.

② After taking off the cover of particle sensor/ humidity sensor on the right upper side,

eliminate dust with soft brush.

③ After cleaning the lens on the upper left side with wet cotton swab and then, get rid of moisture with dry cotton swab.

※ Be careful not to drop the water inside the particle sensor.

④ After cleaning up, assemble it in reverse.※While cleaning, beware not to make damage of particle sensor.

Page 18: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

18

8. Troubleshooting

Symptom Check Point Yes No

Is the power pluginserted properly?When the display is

turned off and theproduct does not work.

Check condition of the filterand clean/replace if necessary.

Check out service life ofdeodorization filter.

Is designated period over?

Is it installed on uneven place?

Check condition of the filterand clean/replace if necessary.

Does the lamp keep lightingred? (Pollution level is high?)

Are you using the productwhere the smell and smoke keep rising?

Fan speed gets weak.

Decreased deodorization.

Product is shacking over.

Bad smell comes out from air outlet.

Request follow-up service.

Replace filters with new ones and clean up pre filter.

Replace deodorization filterwith new one.

Install it on flat surface.

Replace filters with new ones andclean up pre filter.

Set the level of detection sensitivity“dull” or “standard”.

Does the lamp keep lightingblue (pollution level is low?)

Set the level of detection sensitivity“sensitive” or “standard”.

Continuous smell and smoke cancause a performance degradation.

Is power outlet is bad? Use the proper power outlet.

Make sure unit is

properly plugged in.

Request follow-up

service.

Is there any dust stick ontolens of particle sensor? Clean up lens of particle sensor.

Is the sleep mode set?Does displaybutton fades out?

If sleep mode is set, displaybutton gets fading out.

Is the water tank equipped properly?

Humidity setting display isflickering.

Push the disc tank to the end.

Float-type water level sensor is floating on water?

After water tank is filled withwater, ‘No WATER’ displaylamp still is flickering?

Request follow-up service.Clean up the disctank and float-typewater level sensor.

Others If you still have a problem, request follow-up service.

Pollution level display lamp does notchange its color.

Page 19: D H a A a User'sManual Support/User's manual... · Fill the water tank with purified water or tap water. But do not use the hot water over 104F。(40 。C). And clean up the water

8. Troubleshooting

IG

UA

SS

UD·

A

19

Product name IGUASSU D·H·A

Model name CHA-500AH

Power rating Refer to the front page

Power consumption Air purification : 48 W / Humidification : 58 W

Air flow 5.5 ㎥ /min

The amount of humidification 450 ㎖/hr

Applicable area 39 ㎡

Dust collection efficiency 90.2 % (Fine dust 0.3 ㎛)

Deodorization efficiency 95 %

Noise Less than 49.5 dB

Installation

Dimension

Indoor

241 W x 468 D x 618H(㎜)

Net weight 11 kg

9. Specification