    Split Core AC Hall Current Sensor CYHCS-EKADA

    This Hall Effect current sensor is based on open loop compensating principle and designedwith a split core and a highgalvanic isolation between primary and secondary circuits. It canbe used for measurement of AC current, pulse currents etc. The output of the transducerreflects the real wave of the current carrying conductor.

    Product Characteristics Applications

    Excellent accuracy

    Very good linearity

    Using split cores and easy mounting

    Less power consumption

    Window structure

    Electrically isolating the output of thetransducer from the current carryingconductor

    No insertion loss

    Current overload capability

    Photovoltaic equipment

    Frequency conversion timingequipments

    Various power supply

    Uninterruptible power supplies (UPS)Electric welding machines

    Transformer substation

    Numerical controlled machine tools

    Electric powered locomotive

    Microcomputer monitoring

    Electric power network monitoring

    Electrical Data

    Primary NominalRMS Current Ir(A)

    MeasuringRange (A)

    DC OutputCurrent (mA)

    ApertureDiameter (mm)

    Part number

    50 0 ~ 100

    4-20 1.0% 21

    CYHCS-EKADA50A-X

    100 0 ~ 200 CYHCS-EKADA100A-X

    200 0 ~ 400 CYHCS-EKADA200A-X

    400 0 ~ 800 CYHCS-EKADA400A-X

    500 0 ~ 1000 CYHCS-EKADA500A-X

    600 0 ~ 1000 CYHCS-EKADA600A-X

    (X=3, Vcc= +12VDC 5%; X=4, Vcc=+15VDC 5%; X=5, Vcc=+24VDC5%)

    Supply Voltage Vcc= +12V, +15V, +24V 5%,Current Consumption Ic< 20mAGalvanic isolation, 50/60Hz, 1min: 5kV

    Load resistance: 10kIsolation resistance @ 500 VDC > 500 M

    Accuracyand Dynamic performance data

    Accuracy at Ir, TA=25C (without offset), X

  • 7/30/2019 CYHCS-EKADA

    2/2

    Tel.: +49 (0)8121 2574100Fax: +49 (0)8121 2574101Email: [email protected]://www.cy-sensors.com

    Markt Schwabener Str. 8D-85464 FinsingGermany

    Technologies GmbH & Co KG

    General Data

    Ambient Operating Temperature, TA = -40C ~ +85C

    Ambient Storage Temperature, TS=-55C ~ +125C

    PIN Definition and Dimensions

    OFS

    O+

    GI N

    G

    +

    O

    +24V

    G GG

    Notes:

    1. Connect the terminals of power source, outputs respectively and correctly, never makewrong connection.

    2. Two potentiometers can be adjusted, only if necessary, by turning slowly to therequired accuracy with a small screwdriver.

    3. The best accuracy can be achieved when the window is fully filled with bus-bar (currentcarrying conductor).

    4. The in-phase output can be obtained when the direction of current of current carryingconductor is the same as the direction of arrow marked on the transducer

    1(+): Vcc2(G): GND3(O): Output4(G): GND

    OFS GIN

    CYHCS-EKADA

    Vcc: +12V, +15V, +24V

    Output

    GND

    GND

    Io Rm=80~450

    V