47
Brian Kvisgaard System Engineer, CCIE SP #41039 24 May 2016 CVU Cisco NCS 1K/2K/4K update

CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Embed Size (px)

Citation preview

Page 1: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Brian Kvisgaard

System Engineer, CCIE SP #41039

24 May 2016

CVU Cisco NCS 1K/2K/4K update

Page 2: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Service Provider portfolio – Optical focus

Core/ Optical

Data Centre Interconnect

Agg/ Access

NCS-20xx CRS

PRIME

EPN-M

Tail-f NCS

NCS 1K

ASR 900 Series 901/903

Catalyst 4500E/4900

NCS-40xx

NCS 42xx

CTP

ODE

MATE

Multi-layer Planning

tool

ASR 9000 Nexus 7K

IPoDWDM IPoDWDM

IPoDWDM

IPoDWDM IPoDWDM

Page 3: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

NCS 1000 Simplified Transport

Page 4: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Why NCS 1000 ?

Exponential YoY cloud and content traffic growth

Need for rapid scale and automation

Transition from 10GE/40GE to 100GE clients Need 100GE optimized transport solution compatible with 10GE/40GE

Data Center proliferation and network virtualization

Need for DC optimized solutions

Page 5: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

NCS1000 Overview Port Density and Rate Flexibility

20 clients

QSFP28 100G QSFP+ 40G QSFP+ 4x10G

8 Trunks

CFP2-ACO

QSFP-100G-CWDM4

QSFP-100G-LR4

QSFP-100G-SR4

QSFP-40G-CSR4

QSFP-40GE-BIDI QSFP-4x10G-LR R6.0 tested*

Page 6: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Flexible Modulation – Reach vs. Capacity

BPSK 28 GBaud 56 Gbps 50 Gbps 10,000 km

QPSK 32 GBaud 112 Gbps 100 Gbps 6,800 km

16-QAM 35 GBaud 224 Gbps 200 Gbps 1,200 km

Modulation Baud Rate Line Rate Payload Rate Distance

Page 7: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

nLight Silicon Innovation – From 40G to 250G DSP

40G 100G 250G

Fully Integrated ASIC

SW Selectable Modulation

(50G to 250G/Wavelength)

Soft-Decision FEC

(SW Selectable 7% or 20% OH)

Transmit Signal shaping

(Up to 152x Wavelengths in C-band)

Coherent Receiver

Single Wavelength 100G

Integrated DSP & ADCs

(Optimized Performances & Power)

Hard-Decision FEC

(SW Selectable 7% or 20% OH)

50GHz Tunability

(Up to 96x Wavelengths in C-band)

Coherent Receiver

Single Wavelength 40G

Receiver DSP

(Optimized Performances)

Hard-Decision FEC

50GHz Tunability

(Up to 80x Wavelengths in C-band)

Differential Encoding

(Laser Cycle Slip tolerance)

Page 8: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Slice Overview Variety of Client and Trunk Rate Options

ETNA 1 CDR3

QSFP1

QSFP2

QSFP3

QSFP4

QSFP5

CDR3

CDR3

4x

25

4x

25

ETNA 2

FPGA

2x

25 10x1

0

4x

25 2x

25 10x1

0

CFP2 1

CFP2 2

4x

25 4x

25

4x

25

4x

25

4x

25

4x

25 4x

25

4x

25

4x

25 8XPLL

3XPLL

3XPLL

PCIe GEN2 PCIe GEN2

PCIe GEN2

Retimer

Reshape Etherent Statistics

Alarm

LLDP

Multiplexing

WDM Coherent interface

Optical interface

2x100GE to 2x100G

4x100GE to 2x200G

5x100GE to 2x250G

20x10GE to 2x100G

20x10GE to 1x200G

20x10GE to 1x250G

5x40GE to 2x100G

5x40GE to 1x200G

5x40GE to 1x250G

100GE

10GE

40GE

Page 9: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

• Linux kernel with 64 bit IOS-XR OS in a container.

• Carrier-class OS shipping for over a decade and deploying in most tier 1 customers.

• Enhancements allowing for flexibility, customization and programmability.

Software

Page 10: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

NCS2K

Page 11: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

100G Density Summary NCS 2015

• 15 usable slot in the chassis

(14 RU)

• 15x 100G Clients

• 100x 10G Clients

NCS 2006

• 6 usable slot in the chassis

(6 RU)

• 6x 100G Clients

• 40x 10G Clients

NCS 2002

• 2 usable slot in the chassis

(2 RU)

• 2x 100G Clients

• 10x 10G Clients

Page 12: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

NCS 2015 - Chassis Details

14RU Tall

300mm Deep

Can be installed in 23” and in 19”

Front-To-Back Air Flow

2x 50A Redundant Feeds – 4x Feeds total

4x DC Power Modules - Single Feed each

17 Total Number of slots

• 2x Shelf Controller Line Card (1+1 Redundancy)

• 15x General Purposes slots

• 1x Electrical Connection Unit (ECU)

DC Power Modules

Shelf Controllers

ECU

(USB, SFP, RJ45)

Service Modules

(2-16)

DC Lugs

Fan Tray

(w/Integrated LCD)

Air Intake

(w/Integrated Air Filter)

BITS In/Out

& Timing

Page 13: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

• Started shipping 100G SD-FEC Line cards in November 2014, with Release 10.1

• Leverages on Cisco’s 2nd generation nLight Silicon ASIC, which integrates a Coherent DSP, Transmit Signal Shaping and Soft Decision FEC (20% OH)

• 2dB better B2B OSNR vs. HD-FEC Line Cards

• Grid-less Tunability (0.1GHz steps)

• Coherent Select Receiver

• <50ms Protection Switching

• Integrated PRBS for End-to-End Testing & Validation

• Release 10.3 SW enabled 200G (16-QAM) operating mode

Available 100G/200G Line Card

Page 14: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

ROADM

Page 15: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

NCS2K

MD-40

NCS2K

MD-40

* not including outside plant, transponder, OSC or DCU fibers

outside plant outside plant

Two Degree ROADM (SMR-1) One or Two Degrees, Single or Dual Shelf

Total number of line cards for 40ch ROADM 2D Optical Layer: 2

Total number of cables for 40ch ROADM Optical Layer*: 6

All amplifiers are internal to the ROADM

Page 16: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Local Add/Drop

Direction B

To Next Site

Direction B To Next Site

Direction A

MD-40

Express

Wavelengths

MD-40

MD-40 MD-40

To Next Site

Direction D To Next Site

Direction C

Local Add/Drop

Direction A

Mesh Patch Panel

Multi-Degree ROADM (SMR-2) One to Four Degrees, One to Four shelves

Page 17: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Service is brought back up with the same client and optical interfaces, zero touches

Colorless, Omni-directional ROADM switches the path

Through the UNI, the ROADM node instructs the client to re-tune its wavelength

Embedded WSON intelligence locates and verifies a new path (using a different lambda)

WSON Dynamic Optical Restoration

Fiber cut

ONS 15454

MSTP

Client Client

IPoDWDM IPoDWDM

Page 18: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

The nLight ROADM Paradigm Shift Touchless Operation

Complete Control in Software; No Physical Intervention Required

Foundation for Multi-Layer Network Programmability

Omni-Directional – ROADM ports

are not direction-specific (re-route

does not require fiber move)

Flex Spectrum – Ability to provision

the amount of spectrum allocated to

wavelength(s), allowing for 400 Gb

and 1T channels.

Colorless – ROADM ports are not

frequency-specific (re-tuned laser

does not require fiber move)

Contentionless - Same frequency

can be added/dropped from multiple

ports on same device.

Omni-Directional – ROADM ports

are not direction-specific (re-route

does not require fiber move)

Flex Spectrum – Ability to provision

the amount of spectrum allocated to

wavelength(s), allowing for 400 Gb

and 1T channels.

Colorless – ROADM ports are not

frequency-specific (re-tuned laser

does not require fiber move)

Contentionless - Same frequency

can be added/dropped from multiple

ports on same device.

Page 19: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

• Route and Select – One ROADM FS-SMR Line Card per Degree

• Routed Fiber Shuffle – Passive and In-service scalable

• Different solutions for Add/Drop Structure to range from Colored & Directional to Full Contentionless (each FS-SMR port is a different story!)

ROADM Node Architecture Select WSS Route WSS

Degree B

Select W

SS

R

ou

te WS

S

De

gre

e C

Sel

ect W

SS

R

ou

te W

SS

De

gre

e A

Add/Drop Structure

Passive Scalable

Fiber Shuffle

Full MESH

Transponders or

IP-over-DWDM Interfaces

Page 20: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Contentionless ROADM Units in R10.5 Flex Spectrum SMR Contentionless (CCOFS) Add/Drop Fiber Shuffle

• Flex Spectrum Single Slot 20-port WSS

w/Integrated Amplifiers

• Integrated Connection Verification to

guarantee proper cabling & Insertion Loss

• 16-fiber MPO to minimize cabling

• 16-channels Contentionless Add/Drop

scalable in-service to 16-degree

• Single Line Card to scale Add/Drop capacity

and Degree count

• Built-in 4-degree Contentionless

• Fully Passive & Modular Device to

simplify Node Connectivity

• Different Mechanical Form Factors

(1RU to 6RU) available

• Scalable in-service

Page 21: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

20-port Flex Spectrum SMR – Block Diagram Integrated OSC Add/Drop

Filters

21dB Output Power Pre- and

Booster Amplifiers are

integrated in the Single Slot

Line Card

Switchable Gain Pre-

Amplifier: optimized Noise

Figure for any Span Loss

between 0dB and 35dB with

a single Part Number

Connection Verification for

all patch cords within the

Node (“CV” version)

20-port FlexSpectrum Twin

WSS architectures with

12.5GHz resolution

16-fiber MPO Connectors

for extreme density

Page 22: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

20-port Flex Spectrum SMR - Details

EXP 17-20

Ports #17 through #20 in a 16-Fiber MPO Connector

MON-TX & MON-RX

TX & RX Monitor Ports EXP 9-16

Ports #9 through #16 in a 16-Fiber MPO

Connector

EXP 1-8

Ports #1 through #8 in a 16-Fiber MPO

Connector

OSC-TX & OSC-RX

TX & RX Ports for the OTDR/OSC Signal LINE-TX & LINE-RX

Connection To and From the

Span Fibers

Page 23: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

16-channel CCOFS Line Card – Block Diagram

Multicast Switch

Multicast Switch

Allows to map in any combination the 16-

channels to any of the ROADM 4-degree

Requires only one ROADM port per degree

EDFAs Array

Built-in amplification for 4-degrees

A/B Switch Array

Allows to direct any of the 16-channels to

the degree expansion ports

8-fiber MPO

16-fiber MPO 16-fiber MPO

EX

P M

PO

E

XP

MP

O

Page 24: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

16-channels CCOFS Line Card - Details

CHN 9-16

Add/Drop Ports #9 through

#16 in a 16-Fiber MPO

Connector

Used as UPG-#2 for

Number of Degrees

expansion

CHN 1-8

Add/Drop Ports #1 through #8

in a 16-Fiber MPO Connector

Used as UPG-#1 for Number

of Degrees expansion

DEG 1-4

Degree Ports #1 through #4

in a 8-Fiber MPO Connector

UPG #1

Degrees Expansion #1 in a 16-Fiber

MPO Connector

UPG #2

Degrees Expansion #2 in a 16-Fiber

MPO Connector

Page 25: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

16-fiber MPO Fan Out Passive Module

• Passive Optical Module to break-out the

16-port MPO Connector into individual LC

Connectors

• Supports Inventory and Optical Power

Monitoring through the USB port

• PDs available on all the LC TX and RX

Ports

• “ATN” Led can be flashed from GUI to help

installers in the Field

• Can be installed in the 1RU and the 6RU

Mechanical Frames

16-f

ibe

r M

PO

Co

nn

ecto

r

8x d

up

lex L

C C

on

ne

cto

rs

Page 26: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

4- to 16-Degree CCOFS Add/Drop Scalability

Degrees 1-4

Degrees 5-8

Degrees 9-12

Degrees 13-16

16 Add/Drop Channels

• 16-channel Add/Drop uses 1 port per

ROADM Degree (FS-SMR)

• Additional units can be connected to other

available ports to increase Add/Drop

capacity (e.g. 2-port for 32-channels)

Page 27: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Fiber Shuffle

Page 28: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

• Route and Select – One ROADM FS-SMR Line Card per Degree

• Routed Fiber Shuffle – Passive and In-service scalable

• Different solutions for Add/Drop Structure to range from Colored & Directional to Full Contentionless (each FS-SMR port is a different story!)

ROADM Node Architecture Select WSS Route WSS

Degree B

Select W

SS

R

ou

te WS

S

De

gre

e C

Sel

ect W

SS

R

ou

te W

SS

De

gre

e A

Add/Drop Structure

Passive Scalable

Fiber Shuffle

Full MESH

Transponders or

IP-over-DWDM Interfaces

Page 29: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Fiber Shuffle Modules Details – DEG-5

• Basic Building block of the Fiber Shuffle

• Can be used to

• Connect 5 degrees to each other (Full Mesh)

• Connect 4 degrees to each other (Full Mesh) and All of them to one add/drop structure

• Fully Passive Optical module with 5x 8-fiber MPO

• Supports Inventory and Optical Power Monitoring

through USB Connection

• PD available on all the MPO Ports

• “ATN” Led can be flashed from GUI to help

installers in the Field

• Can be installed in the 1RU and the 6RU

Mechanical Frames

MPO #1 MPO #2 MPO #3 MPO #4 MPO #5

Page 30: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Fiber Shuffle Modules Details – UPG-4

MPO #1 MPO #2 MPO #3 MPO #4

MPO #5 MPO #6 MPO #7 MPO #8

• Used to Expand Degree or Add/Drop Capacity

• Can be used to

• Connect 4 degrees to 4 other degrees (Full Mesh)

• Connect 4 degrees to 4 add/drop structure

• Fully Passive Optical module with 8x 8-fiber MPO

• Supports Inventory and Optical Power Monitoring

through USB Connection

• PD available on all the MPO Ports

• “ATN” Led can be flashed from GUI to help

installers in the Field

• Can be installed in the 1RU and the 6RU

Mechanical Frames

Page 31: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

• The 6RU Patch Panel is a passive device integrating an USB 3.1 Hub

• Up to 14x DEG-5 or UPG-4 Optical Modules can be installed to fully build out the Fiber Shuffle for complete Node Scalability

• Single USB 3.0 cable allows to connect the Fiber Shuffle to the NCS 2000 shelf and to detect the presence and the position of each of the Optical Modules installed

• The Node can understand which configuration is being built and to perform checks and report errors or issues (Connection Verification)

6RU Mechanical Frame – Fiber Shuffle

Page 32: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

1T

1R

2T

2R

3T

3R

4T

4R

Connection Verification – FS-SMR Details

• Wavelength #97 Laser and PD integrated in 20-port FS-SMR to:

• Check proper cabling of the SMR to the Patch Panel (PP)

• Measure Insertion Loss of the cabling

• All MPO Connectors on the PP units equipped with PD on Fiber #1

• Configuring the Wavelength #97 signal to port #1 of the MPO allows to verify proper cabling between the SMR and the PP

• 8-fiber in the MPO connectors used for TX and RX interleaved

• All PP units shipped with Loopbacks to be removed only for ports connected to SMR or CDC units

• From SMR and CDC units it is possible to test all paths and validate Insertion Losses

1

MP

O #

1

FS

-SM

R D

rop

F

S-S

MR

Ad

d

MP

O #

3

1T

1R

2T

2R

3T

3R

4T

4R

20

20T

20T

19T

19R

18T

18R

17T

17R

20

1

Page 33: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

TNCS-O: Shelf Controller with Integrated OTDR/OSC

• NCS2K shelf controller: compatible with M15 and M6

• Supports up to 2 Optical Service Channel Termination

with embedded OTDR Capabilities

• Supports USB Management through the ECU

Page 34: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

The OTDR behaves like a ”radar” in the optical domain.

• A probe optical pulse is launched from one fiber’s end

• the resulting back-scattered light is measured against time (or distance from source).

The measurement provides:

• Fiber length

• Fiber type (att. Slope)

• Position and loss / reflections of optical connectors

• Position and loss of splices

• “Visual feedback” of any concentrated event.

OTDR Basics

Page 35: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

TNCS-O W/Integrated OTDR/OSC

• NCS 2015 supports 2x Node Controller Line Cards (TNCS-O)

• Each TNCS-O Line Card supports 2x OTDR/OSC ports

• 1 OTDR per Degree with up to 4 Degrees per NCS 2015 chassis – Dedicated OTDR

• Digital – Bit Stream instead of High Power Optical Pulse

• In Band – Take measurements directly @ 1518nm, no extrapolations

• Bi-directional operation – Tests both fibers and both directions of the fiber with a single device

Page 36: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

NODE A

OTDR & OSC Operations

• Using TX of Near-End XFP and TX on Far-End

allows to scope the Top Fiber Left-to-Right and the

Bottom Fiber Right-to-Left

• OSC flows Left-to-Right in the Top Fiber and Right-

to-Left in the Bottom fiber

• OSC can run in parallel with OTDR scans on the

span fibers – will be available with Hybrid Mode

TX

RX

OTDR

RX

OSC

TX

RX

OTDR

RX

OSC

NODE B

Page 37: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

OTDR Integration Details • Operates In Band @ 1518nm

• Bi-directional operation – Tests both fibers and both directions of the fiber with a single device

• Able to support:

• OTDR-only Operation – During system turn up for faster fiber scanning

• OSC-only Operation – For maximum throughput (e.g. SW Download)

• Hybrid OSC & OTDR Operation (HW Ready) – Continuous monitoring of fiber with OSC connectivity

• OTDR Sensitivity SW Configurable:

• Zone #1 (Up to 1Km) – Fiber Connectivity check through CO Patch Panels

• Zone #2 (Up to 25Km) – Check Insertion Losses and Back Reflection

• Zone #3 (Up to 80Km) – Measurement Accuracy to detect issues w/10m resolution

• Zone #4 (Above 80Km) – Maximum Length spanning w/20m resolution

• Expert Mode – User can manually set Scan parameters

Page 38: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

CTC screenshots

Page 39: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

1

3

2

Page 40: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

When the OTDR measures a variation of Insertion Loss/Reflection

higher than threshold, an entry is raised in the alarm panel.

OTDR_LOSS_THR_EXCEEDED – MJ Major

(note: same description for both Loss and Reflection events)

Page 41: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units
Page 42: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

NCS4200 TDM to Packet Migration

Page 43: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

Cisco NCS4200 Universal Satellites

• Full support for SONET/SDH/PDH MSPP

• Fully Integrated Circuit Emulation for SONET/SDH

• Ethernet and L3 Capabilities

• OTN Switching

• Fully Integrated EMS/NMS solution

• Maximize Network efficiency by aggregating both TDM and Packet

services onto common OTN or Ethernet Uplinks

Access Small Aggregation

• 1, 3 and 7RU Modular Solution

• Pluggable and redundant power modules, AC or

DC

• Pluggable fan tray module

• <240mm deep, fits in 19”, 21” or 23” racks/cabinets

• Front to back airflow options

NCS

4206/4216

TDM or

Ethernet

services

OTN/Packet DWDM

NCS 4016

Packet

TDM NCS 4202

NCS 4201

Page 44: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

TDM Services across the “modernized” Metro

NG

Metro

NG

Metro

NG

Metro

ROADM ROADM ROADM

OTU4

TDM Customer

Premises

Packet

Long Haul

Transport 42xx

Modernized TDM

Customer

OC48s

10GE

MPLS Transport Network Bi-directional LSPs with 1:1 Path Protection

(Working / Protect LSP)

Pseudo-Wire

IP Customer

Premise

10GE 42xx Modernized IP

Customer

DS3/OC3

OC3/OC12/OC

48/OC192

Service

Edges

Primary LSP

Backup LSP

Circuit Emulation Pseudowire

Circuit Emulation

Endpoint

Page 45: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

NG

Metro

NG

Metro

NG

Metro

ROADM ROADM ROADM

OTU4

Vz Packet

TDM

Customer

Premise

Vz Long Haul

42xx

OC48s

10GE

MPLS Transport

FlexLSP 1:1 Path Protection (Working / Protect LSP)

Circuit Emulation

Pseudo-Wire

10GE 42xx

Modernized Central Office

4200

4200 4200

4200 4200

?

Alternative SONET/SDH Migration Approaches

NCS 4200 NCS 4200 NCS 4200

NCS5500 ASR9000 NCS4000

- OTN+Packet

- DWDM Optimized

- 450 Depth

- SyncE

- FlexLSP/TE based

- Unified Core+Edge

- Rich IP features

- SyncE

- FlexLSP/TE/SR

based

- “new DC Style” SP

Approach

- Nitch Feature Set

- No SyncE

- TE/SR based

Page 46: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units

NCS 4200 Family

NCS 4201

NCS 4216

NCS 4206

NCS 4202

Edge Device

Carrier Class

7RU/16 slots

Edge/Access Device

Carrier Class

3RU/6 slots

Pizza box

High Density Ethernet

DS0 CEM Support

Page 47: CVU Cisco NCS 1K/2K/4K update · CVU Cisco NCS 1K/2K/4K update . ... the ROADM node instructs the client to re-tune its wavelength ... ports connected to SMR or CDC units