October 1998 CAT.73.01.T.E Cutler-Hammer B-1 Type CH Loadcenters Index Selection Chart . . . . . . . . . . . . . . . . . . . B-2 Catalog Numbering System. . . . . . . . . B-4 Applications and Warranties . . . . . . . . B-5 1-Phase Main Circuit Breakers Loadcenters . . . . . . . . . . . . . . . . . . . . B-6 1-Phase High Interrupting Rated Main Circuit Breaker Loadcenters . . . . . . . B-7 1-Phase Main Lug . . . . . . . . . . . . B-8 – B-9 3-Phase Main Circuit Breaker Loadcenters . . . . . . . . . . . . . . . . . . . B-10 3-Phase Main Lug . . . . . . . . . . . . . . . . B-11 Convertible, Base Unit and Main Devices . . . . . . . . . . . . . . . . . . B-12 1- and 3-Phase Circuit Breaker Unit Enclosure . . . . . . . . . . . . . . . . . B-13 Type CH Power Centers . . . . . . . . . . . B-14 Accessories . . . . . . . . . . . . . . . B-15 – B-16 Decorator Cover Accessory . . . . . . . . B-17 Surge Protection . . . . . . . . . . . . . . . . . B-18 Plug-On Circuit Breakers . . . . B-19 – B-20 Plug-On Ground Fault Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . B-21 Plug-On Circuit Breakers . . . . . . . . . . B-22 Special Applications Plug-On Circuit Breakers . . . . . . . . . . . . . . . . B-23 Special Application Plug-On CHP Circuit Breakers . . . . . . . . . . B-24 – B-25 Replacement for Square D Type QO Breakers . . . . . . . . . . . . . . B-26 Circuit Breakers Accessories . . . . . . . B-27 Box Sizes . . . . . . . . . . . . . . . . . . . . . . . B-28 Knockouts . . . . . . . . . . . . . . . . B-29 – B-30 Typical Specifications . . . . . . . B-31 – B-32 Page Page

Cutler-Hammer Type CH Loadcenters B-1 October …...CAT.73.01.T.E Cutler-Hammer B-2 October 1998 Type CH Loadcenters Selection Chart Loadcenter Selection Chart Service Single-phase,

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

October 1998

CAT.73.01.T.E

Cutler-Hammer B-1Type CH LoadcentersIndex

Selection Chart . . . . . . . . . . . . . . . . . . .B-2

Catalog Numbering System. . . . . . . . .B-4

Applications and Warranties . . . . . . . .B-5

1-Phase Main Circuit Breakers Loadcenters . . . . . . . . . . . . . . . . . . . .B-6

1-Phase High Interrupting Rated MainCircuit Breaker Loadcenters . . . . . . .B-7

1-Phase Main Lug . . . . . . . . . . . . B-8 – B-9

3-Phase Main Circuit Breaker Loadcenters . . . . . . . . . . . . . . . . . . .B-10

3-Phase Main Lug . . . . . . . . . . . . . . . .B-11

Convertible, Base Unit and Main Devices . . . . . . . . . . . . . . . . . .B-12

1- and 3-Phase Circuit Breaker Unit Enclosure . . . . . . . . . . . . . . . . .B-13

Type CH Power Centers . . . . . . . . . . .B-14

Accessories . . . . . . . . . . . . . . . B-15 – B-16

Decorator Cover Accessory . . . . . . . .B-17

Surge Protection . . . . . . . . . . . . . . . . .B-18

Plug-On Circuit Breakers . . . . B-19 – B-20

Plug-On Ground Fault Circuit Breakers . . . . . . . . . . . . . . . . . . . . . .B-21

Plug-On Circuit Breakers . . . . . . . . . .B-22

Special Applications Plug-On Circuit Breakers . . . . . . . . . . . . . . . .B-23

Special Application Plug-On CHPCircuit Breakers . . . . . . . . . . B-24 – B-25

Replacement for Square D Type QO Breakers . . . . . . . . . . . . . .B-26

Circuit Breakers Accessories . . . . . . .B-27

Box Sizes . . . . . . . . . . . . . . . . . . . . . . .B-28

Knockouts . . . . . . . . . . . . . . . . B-29 – B-30

Typical Specifications. . . . . . . B-31 – B-32

Page Page

CAT.73.01.T.E

Cutler-HammerB-2October 1998

Type CH LoadcentersSelection Chart

Loadcenter Selection Chart

Service ■ Single-phase, three-wire, 120/240V AC.■ Three-phase, three-wire, 240V corner grounded

delta (see accessories).

■ Three-phase, four-wire, 208Y/120V AC.■ Three-phase, three-wire, 240V AC delta.

Short Circuit Current Rating ■ 10,000 AIC: All single- and three-phase loadcenters 40 through 400 amperes 2 to 42 circuits, except when series ratings are applied.

■ 25,000 AIC: All convertible and factory installed single-phase loadcenters rated 150 through 225 amperes using type CSR main breakers.

■ 42,000 and 100,000 are available on some styles: single-phase and three-phase.

Main Breaker/Main LugLoadcenters

Single-Phase

■ Main Breaker: 100, 125, 150, 200, 225, 400 amperes.■ Main Lugs: 40, 70, 125, 150, 200, 225, 400 amperes.

Three-Phase

■ Main Breaker: 150, 200, 225, 300, 400 amperes.■ Main Lugs: 125, 150, 200, 225, 400 amperes.

Convertible Loadcenters ■ Main Breaker or Main Lugs: single-phase up to 225 amperes.

Branch Breakers ■ Type CH: 10 to 150 amperes.One-, two- and three-pole. Two-position tripbreakers. Selected amperages available in,shunt trip, HACR and switching duty.

■ Type CH-HID: 15 to 30 amperes.One-, two- and three-poles.

■ Type CH-PSD: Remotely controlled circuit breaker.Available one-, one and a half-, two-pole.15 to 40 amperes.

■ Type CH-AFCI arc fault circuit interrupter.■ Type CHP: 10 to 125 amperes.

One-, two- and three-pole. Three-positioncommercial trip. Selected amperages available in HACR switching duty.

■ Type CHP-HID: 15-30 amperes.One-, two- and three-pole.

■ Type CH-GFCI: 15-60 amperes.One- and two-pole ground fault breakers

■ Type CHP GFCI: 15-30 amperes.One-pole ground fault breakers.

Enclosures ■ NEMA Type 1 indoor.■ NEMA Type 3R outdoor.

Meets or exceeds UL requirements for indoor oroutdoor applications.

Loadcenter and Breaker Accessories ■ Branch Circuit BreakerAuxiliary components.Hold down kits.Handle ties.Lockoffs.Lockdogs.

■ Complete Line of Ground Bar Kits5, 10, 14, and 21 circuit, some with additional #2/0 lugs. Each terminal will accommodate: (3) #14-#10 Cu/Al or (1) #14-#4 Cu/Al

■ Sub-feed Lugs125, 150 amperes – two- and three-pole.

■ Shunt Trips

■ Surge ProtectionSingle-phase whole home surge protector.Single-phase plug-on surge protector.Single-phase bottle type surge protector.Three-phase bottle type surge protector.Universal Rainproof Conduit Hubs

■ Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches(19.6, 25.4, 31.8, 38.1, 50.8 mm)

■ Group Two: 2, 2-1/2, 3 inches(50.8, 63.5, 76.2 mm)

■ Adapter plate.

Bussing Copper Bus is a standard feature with tin-plated copper branch fingers.

October 1998

CAT.73.01.T.E

Cutler-Hammer B-3Type CH LoadcentersProduct Styles

Single-Phase Main Circuit Breaker –NEMA 1 Enclosure

Three-Phase Main Circuit Breaker –NEMA 3R Enclosure

Single-Phase Main Circuit Breaker – Bottom Feed – NEMA 1 Enclosure

Cutler-Hammer Type CH Convertible Family Advanced Power Center Separately Packaged Covers

Cutler-Hammer Type CH Breaker Family

CAT.73.01.T.E

Cutler-HammerB-4October 1998

Type CH LoadcentersLoadcenter Features – Catalog Numbering System

Extra 1.5-inch Knockoutfor Bundling

Provides for easier installation,less installation time.Top or Bottom Feed

■ Straight-in wiring saves labor and material.

■ Only one panel for eitherapplication – no modifications necessary.

Commercial Grade Main Breaker

■ 25 kAIC series rated main breaker in 150 and 200ampere loadcenters.

■ 42 and 100 kAIC series ratingsavailable.

Steel Backpan

■ Provides positive, reliable breaker mounting.

■ One-piece designed for stability.

Copper Bus

Provides superior conductivitythroughout the entire product line.

Copper Bus Fingers

Tin-plated for longer servicelife, the best in the industry.

Dry Wall Markingon Enclosure

Indicates proper mountingdepth for flush applications.

Single Keyhole Mounting

Just one keyhole at top andbottom for easier mounting and leveling.

Unique Sandalwood Finish

Immediately recognizable,esthetically appealing, scratch resistant powder coating.

Flexible Neutral Design (For styles as indicated)

■ Factory bonded for service entrance applications provid-ing a split neutral.

■ Bonding strap is easily removable for sub-panel applications providing a ground and neutral.

■ Ample additional 2/0 lugs provided; no kits necessary.

Separately Packaged Covers

■ Full line of “true” surface and combination covers.

■ Built-in flush leveling feature■ Choice of circuit identification

by breakers or circuit directory

Improved Endwall Knockouts

Larger KOs are balanced to enhance installed appearance and to ease use of existingwiring.

New Convertible StylesAvailable

■ Uses field installable main breaker or main lug kits.

■ Flexible inventory – same breaker is used in loadcenter and circuit breaker enclosures.

C H 1 4 __ __ L 3 1 0 0 B F

Type CH3/4 inchBranchCircuitBreakers

Blank= Single-Phase

3 = Three-Phase

100 Amp125150200225 B

CDEGJKLR = Outdoor

(No Cover)

F = SubfeedLugsIncluded

Blank = NoSubfeedLugs

LC TypeNumberof Circuits

MainDevice

BusAmps

BoxSize OptionsPhases

Selection 8 Circuits1214161820222428303242

F = CombinationFlush/Surface

S = Surface

C H 8 B F

TypeCH

LoadcenterCover Series

Box Size(Indicated in LoadcenterCatalog Number)

Catalog Numbering System

(Loadcenters 100-225 amperes and 12-42 circuits)

Catalog Numbering System

(Indoor covers to be ordered separately)

L = Main Lug OnlyB = Main BreakerN = ConvertibleH = High AIC Main Breaker

Note: All combinations are not valid,refer to the catalog section.

Twins14/2016/2418/2432/42

October 1998

CAT.73.01.T.E

Cutler-Hammer B-5Type CH LoadcentersApplications and Warranties

Application Information

Loadcenter Construction

CH loadcenters feature solid copperbus and branch fingers in all interiors.Fingers are tin-plated and rated 140 amperes throughout the CH line. There-fore, the sum of the handle ratings con-nected to any one stab is limited to 140 amperes maximum. NEMA 1 boxes are manufactured from cold rolled 16 gauge sheet steel. Raintight boxes are manu-factured from G60 galvanized steel.All boxes and trims are finished usingan electrostatic powder coat, bakedurethane paint process.

UL Listings

All Cutler-Hammer-type CH loadcenters are listed under UL file E8741.

Neutrals

Cutler-Hammer-type CH loadcentersfeature two types of neutrals:

Factory Bonded Split Neutrals –feature a twin neutral (mounted on both sides of the interior assembly) with a cross bus connecting them that is bonded at the factory. For sub-feed applications, the bonding strap can be removed, providing a separate neutral and ground bar. In a service entranceapplication, where the neutral is bonded, unused neutral connections may be used for the termination of equipment grounds.

Insulated/Bondable Single Neutral – When a panel is supplied with a single neutral, it arrives from the factory in an “unbonded” state. All that is required to bond the neutral is to loosen the bond-ing screw and the neutral screw directly beside it, insert the bonding strap into the neutral bar, and re-tighten bothconnections. The single neutral can be moved by the contractor to the other side of the panel, if desired. In a service entrance application, where the neutral is bonded, unused neutral connections may be used for the termination of equipment grounds.

Grounds

Factory Bonded Split NeutralPanels – For service entrance applica-tions, the split neutral doubles as botha neutral and ground. When using the panel as a sub-feed, the bonding strap should be removed, and the bonding screw should be reinstalled, therefore providing a bonded ground and an iso-lated neutral.

Insulated/Bondable Single NeutralPanels – Main lug panels (12 circuit and above) are supplied with a separateneutral and ground bar. Main breaker panels, convertible outdoor panels and panels under 12 circuit are supplied with a neutral bar only. The ground bar must be ordered separately.

Neutral and Ground Terminals

The standard terminals on groundsand neutrals are rated to accept(3) – #14-#10 Cu/Al or (1) – #14-4 wires. For larger cables, add-on neutral lugs may be ordered from the accessories on page B-12.

Bottom-Fed Loadcenters

When the power cable is brought into the loadcenter from below the panel; then the main lug panels, and single-phase, 225 ampere and below, load-centers can be rotated 180 degrees to allow straight-in wiring of power cables to the main terminals. Because the CSR main circuit breaker handle operates horizontally, the orientation of the main circuit breaker handle is consistent with the requirements of NEC Article 240-81.

Gutter Splicing

Loadcenters are not UL listed as wiring troughs. Therefore, gutter splicing of riser cables to tap off to the main device is not permitted.

Fire Rating

Due to the numerous openings in both loadcenter boxes and trims, they should not be mounted in firewalls. There isno approval method for sealing the enclosures for this application.

➀ See Cutler-Hammer Publication Number SA-365 for complete details.

Application Notes and Extended Warranty Highlights

Date Code

The date of manufacture of each load-center is printed on the outside of the carton as well as inside the loadcenter. On the carton, the date code is printed on the end carton label. In the load-center, the date code is located on the small white label located on the right side wall (with the main device on top).

The date code is in the following for-mat: F # # # =. The “F” is the numeric code for the Lincoln, IL plant, and the three numbers are the year and week of manufacture e.g., 823. The “=” sign at the end signifies the decade of the 1990s. Therefore, the date code F823= would indicate that the product was manufac-tured in the 23rd week of 1998. The 1980s are represented by a “+” sign at the end of the code.

Surge Protectors

CHSA – the CHSA is a plug-on surgeprotector that provides protection for the AC power lines only. This device uses indicating lights to signal the need for replacement.

CHSA01 (single-phase) and CHSA03 (three-phase) – these two surge protectors are hard wired to a 15 ampere circuit breaker and provides protection for the AC power lines only. These devices will trip the circuit breaker tosignal the need for replacement.

CHSPCH – the CHSPCH is hard wired to a 2-pole 15 ampere circuit breaker and with proper telephone and coaxial cable connection provides protection for the AC power, telephone and coaxial cable lines. This device uses indicating lights to indicate the need for replacement.

Extended Residential WarrantyHighlights➀

■ Lifetime feeder breaker warranty■ 15-year loadcenter warranty■ Upgradable to 20 years if a Cutler-

Hammer surge protector is installedin the loadcenter.

■ $100,000 limited warranty on Cutler-Hammer high AIC ratedloadcenter.

CAT.73.01.T.E

Cutler-HammerB-6October 1998

MainBreakerType

MainAmpereRating

MaximumNumber3/4-inch (25.4 mm)

EnclosureType

Commercial➀➂LoadcenterCatalog Number

List Price Loadcenter CoverCatalog Number

List Price BoxSize➃

Wire Size RangeCu/Al60°C or 75°Cfor Main Breaker

Space Poles Flush Surface

LD10 kAIC

300 42 42 Indoor CH42PM300 $3495.00 CH7PMF➉ CH7PMS $387.00 PM (2) 400-500 kcmil

400 42 42 Indoor CH42PM400 3495.00 CH7PMF➉ CH7PMS 387.00 PM (2) 400-500 kcmil

1-Phase 3-Wire – 120/240V AC – Factory Bonded Split Neutral

MainBreakerType

MainAmpereRating

MaximumNumber3/4-inch (25.4 mm)

EnclosureType

Loadcenter➀➁Catalog Number

List Price Loadcenter CoverCatalog Number

List Price BoxSize➃

Wire Size RangeCu/Al60°C or 75°Cfor Main Breaker

Space Poles Combination➈ Surface

CH10 kAIC

100 22 22 Indoor CH22B100C➄ $261.00 CH8CF CH8CS $33.50 C #6 - 1/0

125 22 22 Indoor CH22B125C➄ 403.00 CH8CF CH8CS 33.50 C

CSR25 kAIC�

150 32 32 Indoor CH32B150J➄ 483.00 CH8JF CH8JS 72.00 J #2 - 300 kcmil

200 3242

3242

IndoorIndoor

CH32B200J➄CH42B200K➄

497.00580.00

CH8JFCH8KF

CH8JSCH8KS

72.0098.00

JK

Type CH Loadcenters1-Phase with Main Circuit Breakers

➀ All main circuit breaker loadcenters arelisted for use as service entrance equipment.

➁ Loadcenters are factory bonded for service entrance applications. Remove bonding strap for separate neutral and ground bars for sub-feed applications.

➂ Ground bar kits priced separately.See page B-15.

➃ Refer to page B-28 for dimensions.

1-Phase 3-Wire – 120/240V AC – Insulated/Bondable Neutral

MainBreakerType

MainAmpereRating

MaximumNumber3/4-inch (25.4 mm)

EnclosureType

Loadcenter➀➂Catalog Number

List Price Loadcenter CoverCatalog Number

List Price BoxSize➃

Wire Size RangeCu/Al60°C or 75°Cfor Main Breaker

Space Poles Combination➈ Surface

CH10 kAIC

100 1414141418181818223030

141420➇20➇181824➇24➇223030

IndoorOutdoorIndoor

OutdoorIndoor

OutdoorIndoor

OutdoorOutdoorIndoor

Outdoor

CH14B100B➄CH14B100R➅CH1420B100B➄CH1420B100R➅CH18B100C➄CH18B100R➅CH1824B100C➄CH1824B100R➅CH22B100R➅CH30B100D➄CH30B100R➅

$200.00310.00206.00316.00250.00337.00252.00331.00342.00274.00401.00

CH8BF—CH8BF—CH8CF—CH8CF——CH8DF—

CH8BS—CH8BS—CH8CS—CH8CS——CH8DS—

$ 33.50—

33.50—

33.50—

33.50——

62.00—

BBBBCCCCCDD

#6 - 1/0

125 223030

223030

OutdoorIndoor

Outdoor

CH22B125R➅CH30B125D➄CH30B125R➅

635.00464.00685.00

—CH8DF—

—CH8DS—

—62.00

CDD

#6 - 1/0

CSR25 kAIC�

150 8242432

8242432

OutdoorIndoor

OutdoorOutdoor

CH8B150RF➅➆CH24B150E➄CH24B150R➅CH32B150R➅

510.00433.00650.00700.00

—CH8EF——

—CH8ES——

—72.00

——

EEEJ

#2-300 kcmil

200 8242432323242

824243242➇42➇42

OutdoorIndoor

OutdoorOutdoorIndoor

OutdoorOutdoor

CH8B200RF➅➆CH24B200E➄CH24B200R➅CH32B200R➅CH3242B200J➄CH3242B200R➅CH42B200R➅

510.00452.00650.00720.00560.00740.00820.00

—CH8EF——CH8JF——

—CH8ES——CH8JS——

—72.00

——

72.00——

EEEJJJK

#2-300 kcmil

225 32324242

32323232

IndoorOutdoorIndoor

Outdoor

CH32B225J➄CH32B225R➅CH42B225K➄CH42B225R➅

605.00940.00650.00980.00

CH8JF—CH8KF—

CH8JS—CH8KS—

72.00—

98.00—

JJKK

#2-300 kcmil

➄ Indoor loadcenters can be top or bottom fed by rotating the enclosure and trim – 180 degrees.

➅ Rainproof panels are furnished with hubclosure plates. For rainproof hubs,refer to page B-15.

➆ Panel includes #4-300 kcmil feed-through lugs.

➇ Requires the use of CHT breakers.

➈ Combination style covers may be used in surface or flush applications.

➉ This cover is for flush applications only.(not combination)

� 25,000 AIC series combination rating is obtained when types CH, CHT, and CHP branch breakers are used with CSR main.

Discount Symbol 22CD

1-Phase – Main Circuit Breaker Loadcenters10,000/22,000/25,000 Amperes Interrupting Capacity

October 1998

CAT.73.01.T.E

Cutler-Hammer B-7

1-Phase 3-Wire – 120/240V AC – Insulated/Bondable Neutral

MainBreakerType

MainAmpereRating

Maximum Number3/4-inch (25.4 mm)

EnclosureType

Loadcenter➀➁Catalog Number

List Price Loadcenter CoverCatalog Number

List Price BoxSize➂

Wire Size RangeCu/Al60°C or 75°Cfor Main Breaker

Space Poles Combination➇ Surface

CHB442 kAIC➅

100 20202828

20202828

IndoorOutdoorIndoor

Outdoor

CH20H100C➄CH20H100R➃CH28H100D➄CH28H100R➃

$ 365.00444.00464.00545.00

CH8CF—CH8DF—

CH8CS—CH8DS—

$ 33.50—

62.00—

CCDD

#6-1/0

125 2828

2828

IndoorOutdoor

CH28H125D➄CH28H125R➃

600.00745.00

CH8DF—

CH8DS—

62.00—

DD

#6-1/0

CHH100 kAIC➆

150 3232

3232

IndoorOutdoor

CH32H150LCH32H150R➃

915.001165.00

CH8LF—

CH8LS—

126.00—

LL

#2/0-300 kcmil

200 32324242

32324242

IndoorOutdoorIndoor

Outdoor

CH32H200LCH32H200R➃CH42H200LCH42H200R➃

915.001165.00990.00

1275.00

CH8LF—CH8LF—

CH8LS—CH8LS—

126.00—

126.00—

LLLL

#2/0-300 kcmil

225 4242

4242

IndoorOutdoor

CH42H225LCH42H225R➃

1080.001310.00

CH8LF—

CH8LS—

126.00—

LL

#2/0-300 kcmil

Type CH Loadcenters1-Phase with High Interrupting Rated Main Circuit Breakers

➀ All main circuit breaker loadcenters arelisted for use as service entrance equipment.

➁ Ground bar kits priced separately.See page B-15.

➂ Refer to page B-28 for dimensions.➃ Rainproof panels are furnished with hub

closure plates. For rainproof hubs,refer to page B-15.

Discount Symbol 22CD

1-Phase – Main Circuit Breaker Loadcenters42,000/100,000 Amperes Interrupting Capacity

➄ Indoor loadcenters can be top or bottom fed by rotating the enclosure and trim – 180 degrees.

➅ Series rated for 42,000 AIC with all CH, CHT, and CHP breakers.

➆ Series rated for 100,000 AIC with all CH, CHT, and CHP breakers.

➇ Combination style covers may be used in surface or flush applications.

CAT.73.01.T.E

Cutler-HammerB-8October 1998

1-Phase – Main Lug Loadcenters

1-Phase 3-Wire – 120/240V AC – Insulated/Bondable Neutral

MainAmpereRating

Maximum Number3/4-inch (25.4 mm)

EnclosureType

Type of Trim(Included)

LoadcenterCatalog Number

List Price BoxSize➁

Wire Size RangeCu/Al60°C or 75°Cfor Main Lugs

Space Poles

40 222

4➂4➂4➂

IndoorOutdoorIndoor

Surface no Door—

Flush no Door

CH2L40SP➃➀CH2L40RP➃➆➀CH2L40FP➃➀

$ 31.2584.0036.75

55R5

#14-6

70 222

4➂4➂4➂

IndoorOutdoorIndoor

Surface no Door—

Flush no Door

CH2L70SP➃➀CH2L70RP➃➆➀CH2L70FP➃➀

46.5086.5048.50

55R5

#14-2

125 222

4➂4➂4➂

IndoorOutdoorIndoor

Surface no Door—

Flush no Door

CH2L125SP➃➀CH2L125RP➃➆➀CH2L125FP➃➀

56.00101.0070.50

66R6

#14-1/0

444

8➂8➂8➂

IndoorOutdoorIndoor

Surface no Door—

Flush no Door

CH4L125SP➄➀CH4L125RP➄➆➀CH4L125FP➄➀

56.50101.0056.50

77R7

#14-1/0

888

16➂16➂16➂

IndoorOutdoorIndoor

Surface no Door—

Flush no Door

CH8L125SP➅➀CH8L125RP➅➆➀CH8L125FP➅➀

73.00129.0074.00

77R7

#6-1/0

Type CH Loadcenters1-Phase with Main Lugs

➀ Ground bar kits priced separately,see page B-5.– For 2/4 circuit loadcenters use

GBKS or GBK520 ground bar– For 4/8 and 8/16 circuit loadcenters use

GBK10 ground bar– Ground bars mount to the left side wall of

the enclosure for the 4/8 and 8/16 circuitloadcenters.

➁ Refer to page B-28 for dimensions.➂ Requires the use of CHNT breakers.

➃ Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard(see Article 384-14 of the NEC).

➄ Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are pro-vided and when not used as a lighting and appliance panelboard (see Article 384-14 of the NEC).

➅ Suitable for use as service equipmentwhen a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a light-ing and appliance panelboard (see Article 384-14 of the NEC).

➆ Rainproof panels are furnished with hubclosure plates. For rainproof hubs refer to page B-15.

Discount Symbol 22CD

2 Circuits 40 and 70 Amperes 2 Circuits 125 Amperes4 and 8 Circuits 125 Amperes

Surface

Outdoor

Flush Surface FlushSurface no Door Flush no Door

OutdoorOutdoor

October 1998

CAT.73.01.T.E

Cutler-Hammer B-9

MainAmpereRating

Maximum Number3/4-inch (25.4 mm)

EnclosureType

CommercialLoadcenterCatalog Number

List Price Loadcenter CoverCatalog Number

List Price BoxSize➁

Wire Size RangeCu/Al60°C or 75°C

Space Poles Flush Surface

400 42 42 Indoor CH42PL400➈➉ $950.00 CH7PF� CH7PS $366.00 P (2) 1/0 - 300 kcmil(1) 750 kcmil

Type CH Loadcenters1-Phase with Main Lugs

1-Phase – Main Lug Loadcenters, Continued

1-Phase 3-Wire – 120/240V AC – Insulated/Bondable Neutral

MainAmpereRating

Maximum Number3/4-inch (25.4 mm)

EnclosureType

LoadcenterCatalog Number➀

List Price Loadcenter CoverCatalog Number

ListPrice➃

BoxSize➁

Wire Size RangeCu/Al60°C or 75°Cfor Main Lugs

Space Poles Combination Surface

125 12121616161620202424

1212161624➂2420202424

IndoorOutdoorIndoor

OutdoorIndoor

OutdoorIndoor

OutdoorIndoor

Outdoor

CH12L125B➃➅CH12L125R➃➅➇CH16L125B➃➅CH16L125R➃➅➇CH1624L125B➃➅CH1624L125R➃➅➇CH20L125C➃➅CH20L125R➃➅➇CH24L125C➃➅CH24L125R➃➅➇

$ 76.50203.00125.00254.00195.00315.00175.00286.00225.00320.00

CH8BF—CH8BF—CH8BF—CH8CF—CH8CF—

CH8BS—CH8BS—CH8BS—CH8CS—CH8CS—

$33.50—

33.50—

33.50—

33.50—

33.50—

BBBBBBCCCC

#6 - 2/0

150 24243232

24243232

IndoorOutdoorIndoor

Outdoor

CH24L150D➃➅CH24L150R➃➆➇CH32L150D➃➅CH32L150R➃➆➇

205.00387.00216.00399.00

CH8DF—CH8DF—

CH8DS—CH8DS—

62.00—

62.00—

DDDD

#4-300 kcmil

200 12121616

12121616

IndoorOutdoorIndoor

Outdoor

CH12L200D➃➅CH12L200R➃➆➇CH16L200D➃➅CH16L200R➃➆➇

203.00341.00288.00419.00

CH8DF—CH8DF—

CH8DS—CH8DS—

62.00—

62.00—

DDDD

#4-300 kcmil

225 2424323232324242

2424323242➂424242

IndoorOutdoorIndoor

OutdoorIndoor

OutdoorIndoor

Outdoor

CH24L225D➃➅CH24L225R➃➆➇CH32L225D➃➅CH32L225R➃➆➇CH3242L225D➄➅CH3242L225R➄➆➇CH42L225G➄➆CH42L225R➄➆➇

253.00439.00250.00447.00397.00575.00418.00590.00

CH8DF—CH8DF—CH8DF—CH8GF—

CH8DS—CH8DS—CH8DS—CH8GS—

62.00—

62.00—

62.00—

80.00—

DDDDDDGG

#4-300 kcmil

➀ Includes factory installed ground bar.➁ Refer to B-28 for dimensions.➂ Requires the use of CHT breakers.➃ Ground bar GBK14 is installed.➄ Ground bar GBK21 is installed.➅ Suitable for use as service equipment when

a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit catalog number CH125RB. Suitable for use as service equip-ment when not more than six disconnecting

➈ Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a type CHB. The breaker cannot be a type CH.

➉ Ground bar kit priced separately,see page B-15.

� This cover is for flush application only (not combination).

means are provided and when not usedas a lighting and appliance panelboard(see Article 384-14 of the NEC).

➆ Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit catalog number CH125RB.

➇ Rainproof panels are furnished with hubclosure plates. For rainproof hubs refer to page B-15.

CAT.73.01.T.E

Cutler-HammerB-10October 1998

MainBreakerType

MainAmpereRating

Maximum Number3/4 inch (25.4 mm)

EnclosureType

Loadcenter➀➁Catalog Number

List Price Loadcenter CoverCatalog Numbers

List Price BoxSize➂

Wire Size RangeCu/Al60°C or 75°Cfor Main Breaker

Space Poles Combination Surface

CHH100 kAIC➅

200 30304242

30304242

IndoorOutdoorIndoor

Outdoor

CH30H3200LCH30H3200R➃CH42H3200LCH42H3200R➃

$1715.002115.001815.002535.00

CH8LF—CH8LF—

CH8LS—CH8LS—

$126.00—

126.00—

LLLL

#2/0-300 kcmil

225 4242

4242

IndoorOutdoor

CH42H3225LCH42H3225R➃

1960.002745.00

CH8LF—

CH8LS—

126.00—

LL

MainBreakerType

MainAmpereRating

Maximum Number3/4 inch (25.4 mm)

EnclosureType

CommercialLoadcenter➀➁Catalog Number

List Price Loadcenter CoverCatalog Numbers

List Price BoxSize➂

Wire Size RangeCu/Al60°C or 75°Cfor Main Breaker

Space Poles Flush Surface

LD10 kAIC

300 42 42 Indoor CH424PM300 $4265.00 CH7PMF➄ CH7PMS $387.00 PM (2) 3/0-350 kcmil

400 42 42 Indoor CH424PM400 4010.00 CH7PMF➄ CH7PMS 387.00 PM (2) 3/0-350 kcmil

3-Phase 4-Wire – 208Y/120V AC or 240V AC Insulated/Bondable Neutral

MainBreakerType

MainAmpereRating

Maximum Number3/4 inch (25.4 mm)

EnclosureType

Loadcenter➀➁Catalog Number

List Price Loadcenter CoverCatalog Numbers

List Price BoxSize➂

Wire Size RangeCu/Al60°C or 75°Cfor Main Breaker

Space Poles Combination Surface

CC10 kAIC

150 3030

3030

IndoorOutdoor

CH30B3150LCH30B3150R➃

$1135.001480.00

CH8LF—

CH8LS—

$126.00—

LL

#1-4/0

200 30304242

30304242

IndoorOutdoorIndoor

Outdoor

CH30B3200LCH30B3200R➃CH42B3200LCH42B3200R➃

1135.001480.001195.001695.00

CH8LF—CH8LF—

CH8LS—CH8LS—

126.00—

126.00—

LLLL

#2/0-300 kcmil

225 30304242

30304242

IndoorOutdoorIndoor

Outdoor

CH30B3225LCH30B3225R➃CH42B3225LCH42B3225R➃

1235.001605.001285.001820.00

CH8LF—CH8LF—

CH8LS—CH8LS—

126.00—

126.00—

LLLL

Type CH Loadcenters3-Phase with Main Circuit Breaker

➀ All main circuit breaker loadcenters are listed for use as service entrance equipment.

➁ Ground bar kits priced separately.See page B-15.

➂ Refer to page B-28 for dimensions. Discount Symbol 22CD

3-Phase – Main Circuit Breaker Loadcenters10,000/100,000 Amperes Interrupting Capacity

➃ Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs refer to page B-15.

➄ This cover for flush application only.(not combination)

➅ 100,000 AIC series combination rating is obtained when types CH and CHP branch breakers are used with CHH main.

October 1998

CAT.73.01.T.E

Cutler-Hammer B-11

MainAmpereRating

Maximum Number3/4-inch (25.4 mm)

EnclosureType

CommercialLoadcenterCatalog Number

List Price Loadcenter CoverCatalog Numbers

List Price BoxSize➁

Wire Size RangeCu/Al60°C or 75°Cfor Main Lugs

Space Poles Flush Surface

400 42 42 Indoor CH424PL400➈� $1090.00 CH7PF� CH7PS $366.00 P (2) 1/0-300 kcmil(1) 750 kcmil

MainAmpereRating

Maximum Number3/4-inch (25.4 mm)

EnclosureType

LoadcenterCatalog Number

List Price Loadcenter CoverCatalog Numbers

List Price BoxSize➁

Wire Size RangeCu/Al60°C or 75°Cfor Main Lugs

Space Poles Combination Surface

125 121218182424

121218182424

IndoorOutdoorIndoor

OutdoorIndoor

Outdoor

CH12L3125B➃➆CH12L3125R➃➆➉CH18L3125C➃➆CH18L3125R➃➆➉CH24L3125C➃➆CH24L3125R➃➆➉

$188.00304.00270.00386.00283.00422.00

CH8BF—CH8CF—CH8CF—

CH8BS—CH8CS—CH8CS—

$ 33.50—

33.50—

33.50—

BBCCCC

#14-1/0

150 3030

3030

IndoorOutdoor

CH30L3150D➃➆CH30L3150R➃➇➉

330.00515.00

CH8DF—

CH8DS—

62.00—

D #4-300 kcmil

225 242430304242

242430304242

IndoorOutdoorIndoor

OutdoorIndoor

Outdoor

CH24L3225D➃➆CH24L3225R➃➇➉CH30L3225D➃➆CH30L3225R➃➇➉CH42L3225G➄➇CH42L3225R➄➇➉

359.00535.00366.00600.00515.00980.00

CH8DF—CH8DF—CH8GF—

CH8DS—CH8DS—CH8GS—

62.00—

62.00—

80.00—

DDDDGG

#4-300 kcmil

3-Phase – Main Lug Loadcenters

3-Phase 4-Wire – 208Y/120V AC or 240V AC Insulated/Bondable Neutral

MainAmpereRating

Maximum Number3/4-inch (25.4 Mm)

EnclosureType

Type of TrimIncluded

LoadcenterCatalog Number

List Price BoxSize➁

Wire Size RangeCu/Al60°C or 75°Cfor Main Lugs

Space Poles

125 666

12➂12➂12➂

IndoorOutdoorIndoor

Surface No Door—

Flush No Door

CH6L3125SP➅➀CH6L3125RP➅➉➀CH6L3125FP➅➀

$131.00171.00131.00

77R7

#14-1/0

Type CH Loadcenters3-Phase with Main Lugs

Discount Symbol 22CD

➀ Ground bar kits priced separately,see page B-15.– Use GBK10 ground bar– Ground bars mount to the left side wall of

the enclosure.➁ Refer to page B-28 for dimensions.➂ Requires the use of CHNT breakers.➃ Ground bar GBK14 is installed.➄ Ground bar GBK21 is installed.➅ Suitable for use as service equipment when

not more than two service disconnecting means are provided or when not morethan six service disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 384-14 of the NEC).

➆ Suitable for use as service equipmentwhen a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit catalognumber CH125RB. Suitable for use as service equipment when not more than six service disconnecting means are provided and when not used as a lighting and appliancepanelboard (see Article 384-14 of the NEC).

➇ Suitable for use as service equipmentwhen a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down kit catalog number CH125RB.

➈ Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a type CHB. The breaker cannot be a type CH.

➉ Rainproof panels are furnished with hubclosure plates. For rainproof hubs refer to page B-15.

� Ground bar kit priced separately,see page B-15.

� This cover is for flush application only (not combination).

CAT.73.01.T.E

Cutler-HammerB-12October 1998

Outdoor – Single-Phase – 3-Wire – 120/240V – Insulated/Bondable Neutral

MaximumMainAmpereRating

MaximumNumber ofSinglePoles

BoxSize➁

Loadcenter Boxand Panel

Main Lug Kit Main Breaker Kit

CatalogNumber➂

ListPrice

CatalogNumber

ListPrice

WireSize

CatalogNumber

ListPrice

AICRating

WireSize

200 8 E CH8N200RF➆➇ $261.00 CHL225N $151.00 #4-300 kcmil CSR2125NCSR2150NCSR2175NCSR2200N

$295.00 25K #2-300 kcmil

125 22 C CH22N125R➆ 206.00 CHL125N 77.00 #10-1/0 CH2100NCH2125

141.00267.00

10K #10-1/0

200 32 J CH32N200R➆ 290.00 CHL225N 151.00 #4-300 kcmil CSR2125N➄➅CSR2150N➄➅CSR2175N➄➅CSR2200N➄➅

295.00 25K #2-300 kcmil

225 42 K CH42N225R➆ 419.00 CHL225N 151.00 #4-300 kcmil CSR2125N➄➅CSR2150N➄➅CSR2175N➄➅CSR2200N➄➅CSR2225N➄➅

295.00 25K #2-300 kcmil

Indoor – Single-Phase – 3-Wire – 120/240V – Factory Bonded Split Neutral – Top or Bottom Feed

Maximum

Main

Ampere

Rating

Maximum

Number of

Single

Poles

Box

Size➁Loadcenter Box

and Panel

Loadcenter Cover

Catalog Numbers

Main

Lug Kit

Main

Breaker Kit

Catalog

Number➂➃List

Price

Combination Surface List

Price

Catalog

Number

List

Price

Wire

Size

Catalog

Number

List

Price

AIC

Rating

Wire

Size

125 22 C CH22N125C $153.00 CH8CF CH8CS $33.50 CHL125N $ 77.00 #10-1/0 CH2100N

CH2125N

$141.00

272.00

10K #10-1/0

200 32 J CH32N200J 217.00 CH8JF CH8JS 72.00 CHL225N 151.00 #4-300 kcmil CSR2125N➄➅CSR2150N➄➅CSR2175N➄➅CSR2200N➄➅

295.00 25K #2-300 kcmil

225 42 K CH42N225K 292.00 CH8KF CH8KS 98.00 CHL225N 151.00 #4-300 kcmil CSR2125N➄➅CSR2150N➄➅CSR2175N➄➅CSR2200N➄➅CSR2225N➄➅

295.00 25K #2-300 kcmil

Type CH LoadcentersConvertible, Base Units and Main Devices

Convertible Loadcenters MCB or MLO – Base Units and Main Devices10,000/25,000 Amperes Interrupting Capacity➀

Complete assembly consists of: Loadcenter, Cover, and either Main Breaker Kit or Main Lug Kit.

➀ Interrupting rating depends on main circuit breaker selected.

➁ Refer to page B-28 for enclosure dimensions.➂ Panel does not include main. Order main

breaker or main lug kit separately.➃ Loadcenters are factory bonded for service

entrance applications. Remove bonding strap for separate neutral and ground bars for sub-feed applications. Discount Symbol 22CD

➄ 25,000 AIC series combination rating is obtained when types CH, CHT, and CHP branch breakers are used with CSR main.

➅ CSR breakers include line lugs onlyas standard.

➆ Rainproof panels are furnished with hubclosure plates. For rainproof hubs refer to page B-15.

➇ Includes feed-through lugs for both phase and neutral conductors.

October 1998

CAT.73.01.T.E

Cutler-Hammer B-13

CSR Lug Tree Kit For Replacement Purposes OnlyFor Use in Type ECB Unit Enclosures

AmpereRating

Description CatalogNumber

ListPrice

Wire Size RangeCu/Al60°C or 75°C forLine Terminals

225 For use on125, 150, 175, 200and 225 Ampere

CSR Breakers

MCBK225 $84.00 #2-300 kcmil

Type CC Circuit Breakers 240V AC – 10,000 AICFor Use in Type ECC Unit Enclosures

AmpereRating

Type CC10,000 AIC

Type CC Hi Mag10,000 AIC

Wire Size RangeCu/Al60°C or 75°C forLine Terminals

CatalogNumber

ListPrice

CatalogNumber

ListPrice

2-Pole

100125150

CC2100CC2125CC2150

$295.00295.00295.00

CC2100HMCC2125HMCC2150HM

$365.00365.00365.00

#4-4/0

175200225

CC2175CC2200CC2225

295.00295.00295.00

CC2175HMCC2200HMCC2225HM

365.00365.00365.00

#2/0 - 300 kcmil

3-Pole

100125150

CC3100CC3125CC3150

430.00790.00790.00

CC3100HMCC3125HMCC3150HM

505.00855.00855.00

#4-4/0

175200225

CC3175CC3200CC3225

790.00790.00790.00

CC3175HMCC3200HMCC3225HM

855.00855.00855.00

#2/0 - 300 kcmil

Type CSR Circuit Breakers 120/240V AC – 25,000 AICFor Use in Type ECB Unit Enclosures

AmpereRating

2-Pole Breakers Wire Size RangeCu/Al60°C or 75°C forLine Terminals

25,000 AIC

CatalogNumber

ListPrice

125150175200225

CSR2125NCSR2150NCSR2175NCSR2200NCSR2225N

$295.00295.00295.00295.00295.00

#2-300 kcmil

Type CH Loadcenters1- and 3-Phase Circuit Breaker Unit Enclosure

MainAmpereRating

Unit Enclosure Catalog Number Unit Enclosure Catalog Number Type ofCircuitBreaker

Wire Size RangeCu/Al60°C or 75°C

EnclosureType

FlushCover➁

SurfaceCover➁

ListPrice

EnclosureType

RainproofNEMA Type 3R➁

ListPrice

Type ECB Circuit Breaker Unit Enclosures – Order Type CSR Circuit Breaker SeparatelyUnit Enclosure Includes Lug Tree Kit1-Phase 3-Wire – 240V AC Maximum

225 Indoor ECB225F➀➅ ECB225S➀➅ $141.00 Outdoor ECB225R➀➄➅ $270.00 CSR25 kAIC

Type ECB Circuit Breaker Unit Enclosures – Includes Factory Installed CSR Circuit Breaker1-Phase 3-Wire – 240V AC Maximum

150 — — — — Outdoor ECB150RB➂➄➅ 625.00 CSR2150N25 kAIC

200 — — — — Outdoor ECB200RB➃➄➅ 625.00 CSR2200N25 kAIC

Type ECC Circuit Breaker Unit Enclosures – Order Type CC Circuit Breakers Separately1-Phase 3-Wire/3-Phase 4-Wire – 240V AC Maximum

225 Indoor ECC225F➀➅ ECC225S➀➅ 141.00 Outdoor ECC225R➀➄➅ 270.00 CC10 kAIC

1-Phase and 3-PhaseCircuit Breaker Unit Enclosures10,000/25,000 Amperes Interrupting Capacity

➀ Order circuit breaker separately.➁ Dimensions see page B-28.➂ CSR2150N factory installed circuit breaker.➃ CSR2200N factory installed circuit breaker.➄ Rainproof panels are furnished with hub

closures plates. For rainproof hubs refer to page B-15.

➅ One ground lug accepting (1) #14-#2 is factory installed. Also, there are pre-drilled holes to accept a GBK5 ground bar.

➆ Wire size is determined by the circuit breaker installed in enclosure. Maximum wire size and ampere rating is determined by table to the right.

CSR2200N

Wire/Application Maximum

Wire Size

Maximum

Ampere Rating

Aluminum – Standard

250 kcmil 200

Aluminum –Service Entrance

250 kcmil 225

Copper –Standard andService Entrance

250 kcmil 225

Discount Symbol 22CD

Circuit BreakerUnit Enclosures

CAT.73.01.T.E

Cutler-HammerB-14October 1998

Power Center

A special style loadcenter with provisions for installing a Power Manager ™.

Whole Home Power Sensors™Monitor energy consumptionat the incoming line.

Type CH Branch Circuit Breakers1-, and 2-pole, 120/240V AC. 15-60 A, 10 kAIC.

Arc Fault CircuitInterruptersEnhancedprotection from the risk of electrical fires.

Type CH Ground Fault Circuit Breakers1- and 2-pole, 120/240V AC. 15-60 A, up to 22 kAIC.

Type CH Power Centers

Protecting and Controlling Your Home Today and TomorrowThe unique Advanced Power Centersystem provides an easy, reliable, and economical way to monitor and control energy usage in your home.

Cutler-Hammer’s Advanced PowerCenter system makes home controlsolutions an economical reality. This highly reliable system is easy-to-operate, yet inexpensive and easy-to-install…because it uses the equipment found in every home – the loadcenter and existing wiring.

Advanced Power Center SystemConsists of:

■ Power CentersFor installation in new homes or any renovation where a loadcenter is required. Home control capabilities can be easily and inexpensively added whenever the homeowner wants. Power Centers futureproof the home with a minimum investment, and are installed like a standard loadcenter.

■ Power ManagerInstalled by the systems integrator that is installing the integrated home control system. The Power Manager supports industry-standard communi-cations such as X-10®, CEBus®, and INCOM… providing flexibility tointerface with most manufacturers’ home control systems.

■ Power SensorsAdd monitoring capability to any indi-vidual circuit or the incoming service.

■ Power Circuit InterruptersAdd remote control capability ofindividual circuits.

■ Monitor Energy UsageThe homeowner can determine where electrical energy is being used to take advantage of incentives provided by the energy supplier. Major appliances can be monitored to provide early indications of potential failures.

■ Safety and SecurityThe homeowner can also take advan-tage of several capabilities such as:– In event of a fire alarm, turn off the

furnace or air conditioner to pre-vent smoke from spreading, turn off major appliances, and turn on lights so home can be safely exited.

– Turning on outdoor and other lights to provide safe entry on arrival home, or to startle intruders.

– Increased protection from fire haz-ards and electrical shocks is pro-vided when ground fault and arc fault circuit interrupter breakers are installed.

■ Energy SavingsCapabilities to reduce energy costs include turning off nonessential light-ing and appliances when not at home…taking advantage of utility rate-saving structures by controlling appliances to run during the least expensive time-of-day…and taking advantage of billing options and pro-grams offered by energy providers due to deregulation.

■ Enhanced Comfort andConvenienceThe homeowner has control of light-ing, sprinkler systems, heating cables, and appliances.

■ The Advanced Power Center makes home protection and control an affordable reality for just abouteveryone.

■ For more information on the Advanced Power Center� system refer to section A.

Clipper Home Surge ProtectorProtects electronic equipment from spikes and surges.

Power Circuit Interrupters ™Remote controlled branch circuit breakers.

Branch Circuit Power Sensors™Monitor energy consumption on selected branchcircuits.

The Power Manager™Electronic module that provides the communication, monitoring, and control capabilities.

Your Choice of Integrated Home Control Solu-tions

SecuritySystem

Television SmartThermostat

Smart Phone Personal Computer

Programming…Control…Management Right at Your Fingertips!

October 1998

CAT.73.01.T.E

Cutler-Hammer B-15

Ground Bar Kits

Description

(See Legend)

Length Catalog

Number

List Price

Each

Ordering

Quantity➀Inches mm

�������

��������

������������

�������������

���������������

����������������

�����������������

�����������������������

������������������������

�����������������������

2.543.594.295.344.615.696.748.149.197.94

(64.5)(91.9)(109.0)(135.6)(117.1)(144.5)(171.2)(206.8)(233.4)(252.5)

GBK5➁GBK520➁GBK10➁GBK1020➁GBK13➁GBK14➁GBK1420➁GBK21➁GBK2120➁CH9GP21➂➃

$10.20

12.10

11.60

14.50

12.70

13.60

16.80

18.40

19.50

21.70

1111111111

� � � � � � � � � � � � � � �

Field Installation Rainproof Conduit Hubs

Description Conduit Size Catalog

Number

List Price

Each

Ordering

Quantity

➀Inches mm

Group 1 – For use with 70, 100 and 125 AmpereMLO and MCB Loadcenters and Circuit BreakerEnclosures

3/41

1-1/41-1/2

2

19.125.431.838.150.8

DS075H1

DS100H1

DS125H1

DS150H1

DS200H1

$23.60

23.60

23.60

23.60

38.50

11111

Group 2 – For use with 150, 200 and 225 AmpereMLO and MCB Loadcenters and Circuit BreakerEnclosure

22-1/2

3

50.863.576.2

DS200H2

DS250H2

DS300H2

38.50

68.50

80.50

111

Adapter Kit – Allows Installing a Group 1 Hub onDevices Arranged for Group 2 HubsGroup 1 – Small Blank Hub Closure PlateGroup 2 – Large Blank Hub Closure Plate

———

———

DS900AP

CS900CP1

CS900CP2

11.10

1.70

3.30

111

Type CH LoadcentersAccessories

Loadcenter Accessories

Field Installation Kits and Parts

Number

of Poles

Ampere

Rating

Number of

1-inch (25.4 mm)

Spaces Needed

Wire Size

Range Cu/Al

60°C or 75°C

Catalog

Number

List Price

Each

Ordering

Quantity

Sub-Feed Lug Blocks

23

125125

23

#1/0 Maximum#1/0 Maximum

CHSF2125

CHSF3125

$54.50

80.00

1

Neutral/Ground LugAdd-on Neutral or Ground Lug

#2/0 Maximum#3/0 Maximum

300 kcmil Maximum

NL20

NL30

NL300

12.00

14.70

27.25

1

Filler Plates

3/4-inch Space (???) Circuit Breaker SpaceCHFP 2.70 25

Door Lock – 12 through 42 Circuits, and 100 through 225 Amperes TDL 52.00 1

Sandlewood Spray Paint SPCSW 33.25 1

ANSI-61 Light Gray Touchup Paint for Outdoor Loadcenters SPCSW 33.25 1

Isolated Neutral Assembly (Computer Circuits) BINA 7.85 1

Circuit Directory – Adhesive Backed TCD 1.35 10

Cover Screws LCCS .76 25

Cover Replacement Latch 14-5/16 inch (363.55 mm) wide Loadcenters Only CHRLS 7.00 1

Circuit Marking Strip (next to breakers) CHMS 2.30 10

Circuit Identification Label (preprinted breaker labels) CHBL 2.30 25

Series Rated Caution Label SRL 1.45 25

Branch Circuit Numbering Strip CHNS 2.10 20

CHRLS

CHSF2125

TDL

CHFP

CHSF3125

➀ Must be purchased in multiples of ordering quantities indicated.

➁ Distance between mounting holes is 1-3/4 inches (44.5mm). Discount Symbol 22CD

Ground Bar Legend

�(3) #14 - #10 Cu/Al or (1) #14 - #4 Cu/Al�(1) #6 - 2/0 Cu/Al�(1) #14 - #6 Cu/Al or (2) #14 - #12 Cu/Al�(1) 1/8 - 14 or (3) #10 - 12 Cu/Al�(1) #14 - 1/0 Cu/Al or (3) #14 - #10 Cu/Al�(1) #6 - 14 or (2) #10 - 14 Cu/Al�Mounting Hole

� �

➂ For 1- and 3-phase 400 ampere loadcenters.➃ Distance between mounting holes is

2-13/32 inches.

CAT.73.01.T.E

Cutler-HammerB-16October 1998

Grounded ”B“ Phase Adapters

Maximum

Amperes

3-Phase Loadcenter

Types of Panels

Kit Catalog

Number➁List

Price

125 125 Ampere 12-32 CircuitLug Main

CHGRD1 $199.90

225 225 Ampere Main Lugand CHH Main Breaker Panels

CHGRD2 179.00

225 Ampere CC MainCB Panels

CHGRD3 400.00

Type CH LoadcentersAccessories, Continued

Mechanism interlocks two breakers in side-by-side position at the top of the panel. Used to switch normal power to emergency power or alternate branch feeds. UL listed for application with1-, 2- and 3-pole breakers through 100A.

Fits Loadcenter

Numbers

Mechanical Interlock Panel Cover

Catalog Number List Price

Flush Surface

CH12L125B, CH16L125BCH12L3125B, CH14B100B

CH8BFM CH8BSM $187.00

CH20L125C, CH24L125C, CH18L3125C,CH24L3125C, CH22B100C, CH22N100C

CH8CFM CH8CSM 187.00

CH24L150D, CH32L150D,CH24L3225D, CH30L3150D

CH8DFM CH8DSM 229.00

CH42L225G, CH42L3225G CH8GFM CH8GSM 229.00

Inner Cover of Box B RaintightInner Cover of Box C Raintight

CH8BRM

CH8CRM

156.00

➀ These covers do not meet UL1008 fortransfer switches.

➁ Can not be used in Safety Breaker Panels, only in Classic Plus Panels.

CH8BRM

Discount Symbol 22CD

Cover with Mechanical Interlock➀

October 1998

CAT.73.01.T.E

Cutler-Hammer B-17Type CH LoadcentersDecorator Cover Accessory

■ For easy use with CH Loadcenters mounted in living space.■ Easily wallpapered or painted to match any decor.■ Patented Loadcenter accessory – exclusively from Cutler-Hammer.

Now you see it. Now you don’t.

Decorator Cover

Catalog Number

For Use with

CH Loadcenter Cover

Catalog Number

List

Price

CH8KDNB

CH8KDNC

CH8KDND

CH8KDNJ

CH8KDNK

CH8BF

CH8CF

CH8DF/EF

CH8GF/JF

CH8KF

$192.00

205.00

226.00

250.00

260.00

Discount Symbol 22CD

CAT.73.01.T.E

Cutler-HammerB-18October 1998

Description CatalogNumber

ListPrice

Discharge Voltage, V AC Lead LengthInches (mm)1.5 kA 3 kA 5 kA 10 kA

Surge Protector Plug-On Type CH,Single-Phase, 120/240V AC

CHSA $85.00 345 370 500 545 8 (203.2)

Surge Protector, 2-PoleSingle-Phase, 3-Wire, 120/240V AC

CHSA01 49.50 490 640 980 1410 15 (381.0)

Surge Protector, 3-PoleThree-Phase, 4-Wire, 600V AC

CHSA03 100.00 1700 2100 2510 3800 15 (381.0)

Type CH LoadcentersSurge Protection

CHSA SurgeProtector

Surge Protector

CHSA – For use on single-phase, 120/240V AC systems. This easily plugs into a single-phase Type CH loadcenter and occupies two 3/4-inch pole spaces similar to a 2-pole Type CH breaker. When plugged into the first two stabs at the top of the loadcenter just below the main breaker or main lug, it provides surge protection for the entire load-center. If internal components are dam-aged, the CHSA LED visual indicators will signal the need for replacement. This device is suitable for service entry loca-tions installed in accordance with NEC Article 280. The CHSA is ideal for protect-ing sensitive appliances and electronics, such as refrigerators, microwave ovens, and home computers.

Surge Protector

CHSA01 – For use on single-phase, 120/240V AC systems. This surge protector can be easily installed in the enclosure of indoor or outdoor loadcenters by using the 1/2-inch (12.7 mm) threaded nipple. It is ideal for protecting outdoor lighting, garages, sump and irrigation pumps, etc.

Surge Protector

CHSA03 – For use on three-phase, 600V AC systems. This surge protector is installed in the enclosure of indoor and outdoor loadcenters by using the 1/2-inch (12.7 mm) threaded nipple. It pro-vides protection for commercial electri-cal services especially those using electric motors.

CHSA01Surge

Protector

CHSA03Surge

Protector

➀ Refer to Cutler-Hammer CHSP warranty for complete details. Discount Symbol 22CD

CHSP (Clipper Home Surge Protector)

Surge Protectors

Clipper Home Surge Protector

CHSP – This surge protector is an exter-nally mounted TVSS unit that provides industrial level surge protection in aresidential design. It is available in two versions, available in both indoor and outdoor enclosures. The first provides AC power line protection only. The sec-ond provides complete surge protection for your electrical, telephone, and coax-ial cable lines in one convenient unit. Both CHSP models are UL1449 (2ndedition) and 497A listed.

The CHSP is backed by a 5-year product warranty and provides a $10,000 warranty for properly connected equipment.➀

Protection Specifications

AC Power Protection

■ 120/240V (3-wire + ground) ■ 39 kA surge current per phase■ All modes protected ■ Nanosecond response time ■ 24-inch (609.6 mm) leads included for

installation■ Two status indicator lights

Telephone Protection

■ Two incoming lines■ 10 kA per pair surge protection■ PTC polyswitch resetting fuses■ 230V DC gas tube protection

Coaxial Cable Protection

■ Two Cable Type F connectors (input and output)

■ Line-to-shield (ground) protection■ 90V DC gas tube protection

Construction/Safety Specifications

■ UL1449 listed (2nd Edition) UL497A, 400V Rating, CSACertified

■ Tested to ANSI/IEEE Category B3 and C3 levels

■ Unique Surge Plane™ design■ -25°C to +50°C■ Steel enclosure■ 5-year limited warranty

Clipper Home Surge Protector CatalogNumbering System

CHSPCH A R B

ProtectionPosition 1

A = ACProtectionOnly

S = AC,Telephoneand Cable

EnclosurePosition 2

R = Surface/Flush

O = OutdoorEnclosure

PackagingPosition 3

B = Box

P = BlisterPack

CatalogNumber

ListPrice

CHSPCHARBCHSPCHARPCHSPCHAOBCHSPCHAOP

$335.00325.00410.00395.00

CHSPCHSRBCHSPCHSRPCHSPCHSOBCHSPCHSOP

410.00400.00485.00470.00

October 1998

CAT.73.01.T.E

Cutler-Hammer B-19Type CH LoadcentersPlug-On Circuit Breakers

Plug-On Type CH BreakerDescription

Quick-make, quick-break switch mecha-nism combined with inverse time ele-ment tripping operation and trip-free handle design. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short circuit conditions. Multipole breakers have internal common trip connection to oper-ate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker. Type CH breakers meet UL Standard 489, NEMA standards, and Federal Spec Classifica-tion W-C 375 b/Gen. They are UL listed under file number E11713, E8741, E3624 and E51287: and CSA certified file num-ber LR87196, except Type CHT breakers.

Type CH Circuit Breaker Ratings

Single- and double-pole CH breakers rated 15 and 20 ampere have low instan-taneous magnetic trip levels. The 15 and 20 ampere breakers with “HM” suffix have high magnetic trip settings recom-mended for circuits with inherently high inrush currents. All type CH breakers are marked for heating, air conditioning and refrigeration (HACR) equipment applica-tion. Single-pole 15-20 ampere breakers are also suitable for switching duty (SWD). Shunt trip coils operate on 120V AC and require one additional pole space per breaker.

Type CH Circuit Breaker Wire Size Rating

Standard 10,000 AIC branch breakers with and without shunt trip and 10,000 AIC CH breakers with HM or HD suffix.

High Fault Current Application

Types CH and CHT breakers with 10,000 AIC rating can be used in series combi-nation with Cutler-Hammer types CSR, CHH, CHB4 and CHB2 main breakers. The UL listed combination rating will be suitable for applications up to 100,000 ampere of available fault current depend-ing upon the AIC rating of the main.

LatchLever

LatchSpring

LineContactClip

ContactClipSpring Contact

Over-CenterToggle Spring

MagneticPole Piece

Load Terminal

Calibration Screw(under UL label)

CurrentBi-Metal

MagneticArmature

Type CH Circuit Breakers – 10,000 AIC

Two-position trip breakers for ON-OFF operation to eliminate nuisance callbacks.

CAT.73.01.T.E

Cutler-HammerB-20October 1998

Type CH Breakers, 3/4-inch (19.05 mm) per Pole 120, 120/240 or 240 V AC, 10,000 AIC➀

Ampere

Rating

1-Pole 120V AC

Requires One 3/4-inch Space

2-Pole 120/240V AC

Common Trip

Requires Two 3/4-inch Spaces

3-Pole 240V AC

Common Trip

Requires Three 3/4-inch Spaces

Wire Size

Range

Cu/Al

60ºC or 75°10 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton

10 kAIC 10 kAIC 10 kAIC

Catalog Number List Price Catalog Number List Price Catalog Number List Price

1015202530

CH110

CH115➁➂➃CH120➁➂➃CH125➃CH130➃

$18.70

18.70

18.70

18.70

18.70

CH215➁➃CH220➁➃CH225➃CH230➃

$ 43.75

43.75

43.75

43.75

CH315➃CH320➃CH325➃CH330➃

$153.00

153.00

153.00

153.00

(1) #14-8➅(2) #14-10➅➆

(1)#14-6➇

35 CH135➃ 18.70 CH235➃ 43.75 CH335 153.00 #14-2➅#14-6➇

40455060708090

100110125150

CH140➃CH145➃CH150➃CH160➃CH170

18.70

18.70

18.70

18.70

43.75

CH240➃CH245➃CH250➃CH260➃CH270

CH280

CH290

CH2100

CH2110

CH2125

CH2150➄

43.75

43.75

43.75

43.75

91.00

126.00

126.00

126.00

267.00

267.00

348.00

CH340➃CH345➃CH350➃CH360➃CH370

CH380

CH390

CH3100

153.00

153.00

153.00

153.00

200.00

193.00

193.00

625.00

#10-1/0➉#14-2➈#3/0�

Type CH LoadcentersPlug-On Circuit Breakers

The NEC will mandate the use of AFCI protection for 15 and 20 ampere bed-room outlet circuits in the year 2002. Information will be published in the 1999 National Electrical Code.

Plug-On Arc Fault Circuit Breakers, Type CH10,000 Amperes Interrupting Capacity120V AC and 120/240V AC

Type CH Arc Fault Circuit Breakers3/4-inch (19.05 mm) per Pole 120V AC or 120/240V AC

AFCI technology recognizes the unique characteristics of an arcing fault to trip the breaker and interrupt the circuit.

Ampere

Rating

1-Pole

120V AC

Requires One 3/4-inch Space

2-Pole�

120/240V AC

Common Trip

Requires Two 3/4-inch Spaces

Wire Size

Range

Cu/Al

60ºC or 75°

1 per Shelf Carton 1 per Shelf Carton

10,000 AIC 10,000 AIC

Configuration Catalog Number List Price Configuration Catalog Number List Price

15 AFCIAFCI w/GFCI

CH115AF

CH115GFAF

$146.00� AFCIAFCI w/GFCI

CH215AF

CH215GFAF

�(1)#14-8

20 AFCIAFCI w/GFCI

CH120AF

CH120GFAF

$146.00� AFCIAFCI w/GFCI

CH220AF

CH220GFAF

(2)#14-10➆

Type CH 1- and 2-PoleAFCI Circuit Breakers

➀ For factory installed options and pricing, refer to page B-27.

➁ For high magnetic settings, add suffix HM and obtain pricing from page B-27.

➂ Switching duty rated.➃ HACR rated.➄ CH2150 requires 4-pole spaces and is not

suitable for use on 3-phase panels, not CSA certified.

➅ For 1- and 2-pole breakers.➆ Solid and stranded wire can be used together.➇ For 3-pole breakers.➈ 1-pole 40-50 amperes, 2-pole 40-70 amperes.➉ 1-pole 60-70 amperes, 2-pole 80-125 amperes,

3-pole 40-100 amperes.� 2-pole 150 amperes.

Discount Symbol 22CD

Plug-On Circuit Breakers, Type CH10,000 Amperes Interrupting Capacity120V AC, 120/240V AC and 240V AC

� Two-pole AFCI breakers are designed for use in 3-wire, 120/240V AC circuits, 120V AC multiwire circuits utilizing a shared neutral (often referred to as a “home run” circuit), and 240V AC circuits obtained from 120/240V AC source.

� Availability to be announced.

October 1998

CAT.73.01.T.E

Cutler-Hammer B-21

Type CH Ground Fault Circuit Breakers (5 Milliampere)3/4-inch (19.05 mm) per Pole 120V AC or 120/240V AC,10,000 AIC

Ampere

Rating

1-Pole

120V AC

Requires One 3/4-inch Space

2-Pole

120/240V AC

Common Trip

Requires Two 3/4-inch Spaces

Wire

Size

Range

Cu/Al

60ºC or

75°C1 per Shelf Carton 1 per Shelf Carton

10,000 AIC 10,000 AIC

Catalog Number List Price Catalog Number List Price

152025303540455060

CH115GF

CH120GF

CH130GF

$150.00

150.00

150.00

CH215GF

CH220GF

CH225GF

CH230GF

CH235GF

CH240GF

CH245GF

CH250GF

CH260GF

$267.00

267.00

267.00

267.00

267.00

267.00

267.00

267.00

267.00

#14-6

Plug-On Ground Fault Circuit Breakers, Type CH10,000 Amperes Interrupting Capacity120V AC and 120/240V AC

Type CH LoadcentersPlug-On Ground Fault Circuit Breakers

Type CH 1-Pole Type CH 2-Pole

Type CH Ground Fault Equipment Protectors (30 Milliampere)3/4-inch (19.05 mm) per Pole 120V AC or 120/240V AC,10,000 AIC

Ampere

Rating

1-Pole

120V AC

Requires One 3/4-inch Space

2-Pole

120/240V AC

Common Trip

Requires Two 3/4-inch Spaces

WireSizeRangeCu/Al60ºC or75°C1 per Shelf Carton 1 per Shelf Carton

10,000 AIC 10,000 AIC

Catalog Number List Price Catalog Number List Price

152030405060

CH115EPD

CH120EPD

CH130EPD

$239.00

239.00

239.00

CH215EPD

CH220EPD

CH230EPD

CH240EPD

CH250EPD

CH260EPD

$403.00

403.00

403.00

403.00

403.00

403.00

#14-6

Ground Fault Application Notes

Single-pole Type CHGFIs are designed for use in 2-wire, 120V AC circuits. Figure 1 shows a typical wiring configuration.

Two-pole Type CHGFIs are designed for use in 3-wire, 120/240V AC circuits, 120V AC multi-wire circuits employing common, neutral and 2-wire, 240V AC circuits obtained from a120/240V AC source.

Figures 2 and 3 illustrate typical wiring config-urations for a 120/240V AC multiwire circuits.

Figure 4 depicts a 240V AC, 2-wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120V AC power source to the ground fault sensing circuit.

The figures are shown with a 120/240V AC,single-phase, 3-wire power source, but are also applicable to a 120/208V AC, 3-phase, 4-wire power supply. For all figures the electrical operation of the Type CHGFI is not affectedby the equipment ground.

Figure 11-Pole

Figure 32-Pole

Figure 22-Pole

Figure 42-Pole

Discount Symbol 22CD

CAT.73.01.T.E

Cutler-HammerB-22October 1998

Type CH LoadcentersPlug-On Circuit Breakers – CTL and Non-CTL Twins

CTL Plug-On Circuit Breakers, Type CHT Twin10,000 Amperes Interrupting Capacity120/240V AC

Type CHT Twin (CTL)3/4-inch (19.05 mm) per Pole 120V AC

Class CTL 10,000 AIC – All circuitbreakers have rejection feature. Use only with loadcenters marked for use with CHT breakers.

Ampere

Rating

1-Pole

Requires One 3/4-inch Space

Wire

Size

Range

Cu/Al

60ºC or

75°C

10 per Shelf Carton

10,000 AIC

Catalog Number List Price

15-1515-2020-20

CHT1515➀➁CHT1520➀➁CHT2020➀➁

$44.75

44.75

44.75

#14-8

➀ Switch duty rated.➁ HACR rated.

Non-CTL Plug-On Replacement Circuit Breakers, Type CHNT10,000 Amperes Interrupting Capacity120/240V AC

Type CHNT3/4-inch (19.05 mm) per Pole 120V AC

Non-CTL 10,000 AIC – For use as replace-ment in loadcenters built prior to 1968 and within the current style 2-8 circuit loadcenters as indicated in the load-center section.

Ampere

Rating

1-Pole

Requires One 3/4-inch Space

Wire

Size

Range

Cu/Al

60ºC or

75°C

10 per Shelf Carton

10,000 AIC

Catalog Number List Price

15-1515-2020-20

CHNT1515➀➁CHNT1520➀➁CHNT2020➀➁

$47.25

47.25

47.25

#14-8

120V AC120V AC

120V AC120V AC

Discount Symbol 22CD

October 1998

CAT.73.01.T.E

Cutler-Hammer B-23

Type CH Neutral Switching Breakers,3/4-inch (19.05 mm) per Pole 120/240 or 240 V AC, 10,000 AIC

Used to open the neutral along power line(s) for applications of gas pumps.

Ampere

Rating

2-Pole

120V AC

Common Trip

Requires Two 3/4-inch Spaces

3-Pole

120/240V AC

Common Trip

Requires Three 3/4-inch Spaces

Wire

Size

Range

Cu/Al

60ºC or

75°C1 per Individual Carton 1 per Individual Carton

10,000 AIC 10,000 AIC

Catalog Number List Price Catalog Number List Price

1520304050

CH215SW➀CH220SW➀CH230SW➀CH240SW➀CH250SW➀

$68.00

68.00

68.00

68.00

68.00

CH315SW➀CH320SW➀CH330SW➀CH340SW➀CH350SW➀

$98.00

98.00

98.00

98.00

98.00

#14-8

Type CH LoadcentersSpecial Applications Plug-On Circuit Breakers

CH Neutral Switching Breakers10,000 Amperes Interrupting Capacity120V AC and 120/240V AC

CH220SW

CH-HID Circuit Breakers10,000 Amperes Interrupting Capacity120V AC, 120/240V AC and 240V AC

Type CH-HID Circuit Breakers, 3/4-inch (19.05 mm) per Pole 120V AC,120/240 and 240 V AC, 10,000 AIC

Suitable for use in circuits for fluorescent and High Intensity Discharge lighting.Also suitable for HACR applications.

Ampere

Rating

1-Pole

120V AC

Requires One 3/4-inch Space

2-Pole

120/240V AC

Common Trip

Requires Two 3/4-inch Spaces

3-Pole

240V AC

Common Trip

Requires Three 3/4-inch Spaces

Wire

Size

Range

Cu/Al

60ºC or

75°10 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton

10,000 AIC 10,000 AIC 10,000 AIC

Catalog Number List Price Catalog Number List Price Catalog Number List Price

152030

CH115HID

CH120HID

CH130HID

$38.25

38.25

38.25

CH215HID

CH220HID

CH230HID

$84.00

84.00

84.00

CH315HID

CH320HID

CH330HID

$223.00

223.00

223.00

#14-8

➀ For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space. Obtain pricing from page B-27.

Neutral InNeutral OutPhasePhase

Neutral InNeutral Out(Hot leg)

Discount Symbol 22CD

CAT.73.01.T.E

Cutler-HammerB-24October 1998

Type CHP-GFCI➀ Breakers (5 Milliampere) 3/4-inch (19.05 mm) per Pole 120 V ACand 120/240, 10,000 AIC

Ampere

Rating

1-Pole

120V AC

Requires One 3/4-inch Space

Wire Size

Range

Cu/Al 60ºC

or 75°C

1 per Individual Carton

10,000 AIC

Catalog Number List Price

152030405060

CHP115GF

CHP120GF

CHP130GF

$210.00

210.00

210.00

#14-6

Type CH LoadcentersSpecial Application Plug-On CHP Circuit Breakers

CHP➀ Commercial Breakers10,000 Amperes Interrupting Capacity120V AC, 120/240V AC and 240V AC

Type CHP➀ Breakers, 3/4-inch (19.05 mm) per Pole 120, 120/240 or 240 V AC, 10,000 AIC

Ampere

Rating

1-Pole

120V AC

Requires One

3/4-inch Space

2-Pole

120/240V AC

Common Trip

Requires Two

3/4-inch Spaces

3-Pole

240V AC

Common Trip

Requires Three

3/4-inch Spaces

Wire

Size

Range

Cu/Al

60ºC or

75°C10 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton

10,000 AIC 10,000 AIC 10,000 AIC

Catalog Number List Price Catalog Number List Price Catalog Number List Price

1015202530

CHP110

CHP115➁➂➃CHP120➁➂➃CHP125➃CHP130➃

$27.50

27.50

27.50

26.30

26.30

CHP210

CHP215➁➃CHP220➁➃CHP225➃CHP230➃

$55.00

57.50

57.50

55.00

57.50

CHP310

CHP315➃CHP320➃CHP325➃CHP330➃

$210.00

210.00

219.00

210.00

219.00

(1) #14-8➄(2) #14-10➄➅

(1)#14-6➆

35 CHP135➃ 26.30 CHP235➃ 55.00 CHP335➃ 210.00 #14-2➄#14-6➆

40455060708090

100110125

CHP140➃CHP145➃CHP150➃CHP160➃CHP170

26.30

26.30

26.30

26.30

48.30

CHP240➃CHP245➃CHP250➃CHP260➃CHP270

CHP280

CHP290

CHP2100

CHP2110

CHP2125

57.50

55.00

57.50

55.00

106.00

160.00

160.00

160.00

305.00

305.00

CHP340➃CHP345➃CHP350➃CHP360➃CHP370

CHP3100

210.00

210.00

210.00

210.00

262.00

273.00

#10-1/0➈#14-2➇

CHP-GFCI➀ Circuit Breakers10,000 Amperes Interrupting Capacity120V AC and 120/240V AC

➀ CHP Breakers offer on-off and trip positions for commercial applications.

➁ For high magnetic settings, add suffix HM and obtain pricing from page B-27.

➂ Switching duty rated.

Ground Fault Application Notes

Single-pole Type CHPGFIs are designed for use in 2-wire, 120V AC circuits. Figure 1 shows a typical wiring configuration.

The figure is shown with a 120/240V AC,single-phase, 3-wire power source, but are also applicable to a 120/208V AC, 3-phase, 4-wire power supply. For all figures the electrical operation of the Type CHPGFI is not affected by the equipment ground.

Figure 11-Pole

➃ HACR rated.➄ For 1- and 2-pole breakers.➅ Solid and stranded wire can be used together.➆ For 3-pole breakers.➇ 1-pole 40-50 amperes, 2-pole 40-70 amperes. Discount Symbol 22CD

➈ 1-pole 60-70 amperes, 2-pole 80-125 amperes, 3-pole 40-100 amperes.

October 1998

CAT.73.01.T.E

Cutler-Hammer B-25

Type CHP-HID Circuit Breakers, 3/4-inch (19.05 mm) per Pole120V AC, 120/240 and 240 V AC, 10,000 AIC

Suitable for use in circuits for fluorescent and High Intensity Discharge lighting.Also suitable for HACR applications.

Ampere

Rating

1-Pole

120V AC

Requires One

3/4-inch Space

2-Pole

120/240V AC

Common Trip

Requires Two

3/4-inch Spaces

3-Pole

240V AC

Common Trip

Requires Three

3/4-inch Spaces

Wire

Size

Range

Cu/Al

60ºC or

75°C10 per Shelf Carton 5 per Shelf Carton 5 per Shelf Carton

10,000 AIC 10,000 AIC 10,000 AIC

Catalog Number List Price Catalog Number List Price Catalog Number List Price

152030

CHP115HID

CHP120HID

CHP130HID

$41.00

41.00

41.00

CHP215HID

CHP220HID

CHP230HID

$92.50

92.50

92.50

CHP315HID

CHP320HID

CHP330HID

$260.00

260.00

260.00

#14-6

Type CHP Neutral Switching Breakers, 3/4-inch (19.05 mm) per Pole120/240 or 240 V AC, 10,000 AIC

Used to open the neutral along power line(s) for applications of gas pumps.

Ampere

Rating

2-Pole

120/240V AC

Common Trip

Requires Two 3/4-inch Spaces

3-Pole

240V AC

Common Trip

Requires Three 3/4-inch Spaces

Wire

Size

Range

Cu/Al

60ºC or

75°C1 per Shelf Carton 1 per Shelf Carton

10,000 AIC 10,000 AIC

Catalog Number List Price Catalog Number List Price

1520304050

CHP215SW➀CHP220SW➀—

$78.00

81.00

CHP315SW➀CHP320SW➀—

$136.00

136.00

#14-8

Type CH LoadcentersSpecial Application Plug-On CHP Circuit Breakers

➀ For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space, obtain pricing from B-27.

CHP-HID Circuit Breakers10,000 Amperes Interrupting Capacity120V AC, 120/240V AC and 240V AC

Discount Symbol 22CD

CHP Neutral Switching Breakers10,000 Amperes Interrupting Capacity120V AC and 120/240V AC

CAT.73.01.T.E

Cutler-HammerB-26October 1998

CHQ Breaker Accessories

Description Catalog

Number

List

Price

Breaker Padlocking DeviceBreaker Handle LockGround Fault Padlocking Device

CHQPL

CHLO

CHQPLGF

$4.50

2.10

6.00

Type CHQ Surge Arrester

Catalog Number List Price

CHQSA $103.00

Type CH LoadcentersReplacement for Square D® Type QO® Breakers

Type CHQ Classified Breakers 3/4-inch (19.05 mm) per Pole 120/240 or 240 V AC, 10,000 AIC

Ampere

Rating

1-Pole

120V AC

Requires One 3/4-inch Space

2-Pole

120/240V AC Common Trip

Requires Two 3/4-inch Spaces

Wire Size

Range

Cu/Al

60ºC or

75°C10 per Shelf Carton 5 per Shelf Carton

10,000 AIC 10,000 AIC

Catalog Number List Price Catalog Number List Price

1520253035404550

CHQ115

CHQ120

CHQ125

CHQ130

CHQ135

CHQ140

CHQ145

CHQ150

$16.90

16.90

16.90

16.90

16.90

16.90

16.90

16.90

CHQ215

CHQ220

CHQ225

CHQ230

CHQ235

CHQ240

CHQ245

CHQ250

$39.25

39.25

39.25

39.25

39.25

39.25

39.25

39.25

(1) #14-8(2) #14-10

Type CHQ Classified Breakers10,000 Amperes Interrupting Capacity120V AC and 120/240V AC

CHQ120

Type CHQ Ground Fault 10,000 Amperes Interrupting Capacity120V AC and 120/240V AC

CHQ115GF

Type CHQ Ground Fault (5 Milliampere) 3/4-inch (19.05 mm) per Pole 120/240 or 240 V AC, 10,000 AIC

Ampere

Rating

1-Pole

120V AC

Requires One 3/4-inch Space

2-Pole

120/240V AC Common Trip

Requires Two 3/4-inch Spaces

Wire

Size

Range

Cu/Al

60ºC or

75°C10 per Shelf Carton 5 per Shelf Carton

10,000 AIC 10,000 AIC

Catalog Number List Price Catalog Number List Price

1520304050

CHQ115GF

CHQ120GF

CHQ130GF

$150.00

150.00

150.00

CHQ215GF

CHQ220GF

CHQ230GF

CHQ240GF

CHQ250GF

$266.00

266.00

266.00

266.00

266.00

(1) #14-8(2) #14-10

Ground Fault Application Notes

Single-pole Type CHQGFIs are designed for use in 2-wire, 120V AC circuits. Figure 1 shows a typical wiring configuration.

Two-pole Type CHQGFIs are designed for use in 3-wire, 120/240V AC circuits, 120V AC multi-wire circuits employing common, neutral and 2-wire, 240V AC circuits obtained from a 120/240V AC source.

Figures 2 and 3 illustrate typical wiring config-urations for a 120/240V AC multiwire circuits.

Figure 4 depicts a 240V AC, 2-wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120V AC power source to the ground fault sensing circuit.

The figures are shown with a 120/240V AC, sin-gle-phase, 3-wire power source, but are also applicable to a 120/208V AC, 3-phase, 4-wire power supply. For all figures the electrical operation of the Type CHQGFI is not affected by the equipment ground.

Warranty Information

15-year warranty on the replacementcircuit breaker and Square D� QO� load-center. See publication SA-103 for full details.

Square D� and QO� are registered trade-marks of The Square D Company.

Figure 11-Pole

Figure 32-Pole

Figure 22-Pole

Figure 42-Pole

Discount Symbol 22CDCHQSA

October 1998

CAT.73.01.T.E

Cutler-Hammer B-27

Shunt Trips, Auxiliary, Alarm Contacts and High Magnetic Options

Description Catalog

Number➈List Price

Adder Each

Shunt Trip for

Type CSR– 12 Volt– 24 Volt– 120 Volt

Type CH– 120 Volt

Add Suffix:

SR12

SR24

SR01

ST➉

$392.00

392.00

392.00

121.60

Auxiliary Contact for

Type CSR– (1) N.O. and (1) N.C.– (2) N.O. and (2) N.C.

AL1

AL2

170.00

334.00

Alarm Contact for

Type CSR CR1 170.00

High Magnetics

Type CH HM 2.60

Type CH LoadcentersCircuit Breaker Accessories

� Handle Position Changeability Chart

Handle Lockoff

and Lockdog

Types

To Change Handle Position from

“On to “Off,” or “Off” to “On”

You Must...

Remove

Padlock

Remove

Device

Remove

Load-

center

Deadfront

LockoffEscutcheonMounted

Remove — —

Lockoff ScrewMounted

Remove — —

Lockdog HandleMounted

N/A Remove —

➀ Handle Ties: Typically used to join two simi-lar independent single-pole breakers to form a 2-pole noncommon trip breaker.

➁ Handle Lockoffs: Devices that use a padlock to lock the circuit breaker’s handle in the “On” or “Off” position.

➂ Handle Lockdogs: Devices that are used to secure a circuit breaker’s handle in the “On” or “Off” position. Handle Lockdogs are not padlockable devices.

➃ Hold-Down Kits: Devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384-16(f).

Discount Symbol 22-CD

➄ Escutcheon Mounted: Device mounted semi-permanently to the face of the circuit breaker and secured by the loadcenter deadfront.

➅ Handle Mounted: Device mounted above or below handle using spring pressure.

➆ Screw Mounted: Device permanently mounted to the face of the circuit breaker by the use of a non-removable screw.

➇ Must be purchased in multiples of ordering quantities indicated.

➈ Add suffix indicated to end of breaker catalog number.

➉ Requires one additional pole space.

CHHT

MCBPL (Installed)

CH125RB

Circuit Breaker Accessories

Field Installation Kits and Parts

Description Catalog

Number

List Price

Each

Ordering

Quantity➇

Handle Ties➀Handle tie bar for physically joining the handles of twoadjacent 1-pole Type CH Circuit Breakers. (Molded PlasticHandle Cover) CHHT $ .96 25

Handle Lockoffs➁➉Padlockable device for locking the handle of 1-, 2-, or 3-poleType CH Circuit Breakers (Escutcheon Mounted)➄ CHPL 6.35 1

Padlockable device for locking the handle of a 1-, 2- or3-pole Type CHGFI Circuit Breaker. (Escutcheon Mounted)➄ CHPLGF 6.25 1

Padlockable device for locking the handle of main circuitbreaker Types CC and CCH into the “On” or “Off” position.(Screw Mounted)➆ CCPL 21.60 1

Padlockable device for locking the handle of main breakerTypes CCH and CSR into the “On” or “Off” position.(Escutcheon Mounted)➄ MCBPL 25.25 1

Handle Lockdogs➂➉Device used to secure handle in “On” or “Off” position for1-pole Type CH Circuit Breakers. (Handle Mounted)➅ CHL0 2.30 10

Hold-Down Kits➃Hold-down retainer kit for 1-,2-, 3-Pole Type CH Circuit Break-ers. For 6-24 circuit 125 ampere single and 3-phase, 12-42circuit single-phase 225 ampere and 24-42 circuit 3-phase225 ampere MLO Type CH Loadcenters.

CH125RB 3.95 1

Hold-Down Kits➃Hold-down retainer kit for 1-,2-, 3-Pole Type CH Circuit Breakers for 2 through 4 circuit MLO CH Loadcenters.

CH125RB24 9.60 1

Mounting Bases

Mounting base for 2-Pole Type CH Circuit Breaker –70 ampere maximum CH9MB270 18.40 1

Main Breaker Lug Kits

Types CC and CCH Main Breaker Lug Kit (2) 300 kcmil.Type CSR Main Breaker Lug Kit (2) 300 kcmil.

CCL300

MCBL300

41.50

43.50

11

CHPL

CHLO MCBPL

CHPLGF

CH9MB270

CAT.73.01.T.E

Cutler-HammerB-28October 1998

Types ECB and ECC Unit EnclosuresNEMA Type 3R Outdoor

Dimensions in Inches Dimensions in mm

Height Width Depth Height Width Depth

23-11/16 9-5/16 5-7/16 601.4 236.5 138.1

Types ECB and ECC Unit EnclosuresNEMA Type 1 Indoor

Dimensions in Inches Dimensions in mm

Height Width Depth Height Width Depth

23-1/4 8-7/8 4-1/2 590.3 255.3 114.3

Type CH LoadcentersBox Sizes

Residential LoadcentersNEMA Type 3R Outdoor

BoxSize

Dimensions in Inches Dimensions in mm

Height Width Depth Height Width Depth

5R6R7RBCDEGJKL

9-1/211-1/2

1316-3/4

2129-1/829-1/834-1/834-1/8

3739

4-1/26-1/8

1114-5/1614-5/1614-5/1614-5/1614-5/1614-5/1614-5/1614-5/16

3-1/84-15/323-11/165-3/165-3/165-3/165-3/165-3/165-3/165-3/165-3/16

241.3292.1330.1425533740740867867940991

114.3155.6279.3364364364364364364364364

79.4114.390.5131.8131.8131.8131.8131.8131.8131.8131.8

Commercial LoadcentersNEMA Type 1 Indoor

BoxSize

Dimensions in Inches Dimensions in mm

Height Width Depth Height Width Depth

PPM

54-3/862-5/8

2121

66

13811591

533533

152152

Residential LoadcentersNEMA Type 1 Indoor

BoxSize

Dimensions in Inches Dimensions in mm

Height Width Depth Height Width Depth

567BCDEGJKL

9-1/211-3/8

1316-3/4

2129-1/829-1/834-1/834-1/8

3739

4-1/26-7/8

1114-5/1614-5/1614-5/1614-5/1614-5/1614-5/1614-5/1614-5/16

3-1/83-25/643-11/163-7/83-7/83-7/83-7/83-7/83-7/83-7/83-7/8

241.3288.9330.1425533740740867867940991

114.3174.6279.3364364364364364364364364

7986939898989898989898

Residential/Commercial/Unit Enclosure – Box Sizes➀

➀ Box sizes do not include covers/fronts.

October 1998

CAT.73.01.T.E

Cutler-Hammer B-29

Knockouts for Box Sizes 5, 6, 7, 5R, 6R, 7R

Code Diameter in Inches Diameter in mm

A 1/2 — — — 12.7 — — —

B 1/2 3/4 — — 12.7 19.0 — —

C 1/2 3/4 1 — 12.7 19.0 25.4 —

D 1/2 3/4 1 1-1/4 12.7 19.0 25.4 31.7

E 3/4 1 1-1/4 — 19.0 25.4 31.7 —

F 3/4 1 1-1/4 1-1/2 19.0 25.4 31.7 38.1

G 1 1-1/4 1-1/2 – 25.4 31.7 38.1 —

H 1 1-1/4 1-1/2 2 25.4 31.7 38.1 50.8

I 1-1/4 1-1/2 2 — 31.7 38.1 50.8 —

Type CH LoadcentersKnockouts

Residential Loadcenter Knockouts Dimensions in Inches (mm)

Residential NEMA Type 1 Indoor and NEMA Type 3R Outdoor Enclosures

Box 6R Box 7 Box 7R

Box 5 Box 5R Box 6

A

A

A

A

A

A

D D D

D

F

F

A

A

D D D

F

Hub

A

A

BA

B

B

C

C

F F

FF

AB

F

F

H

A

B

A

BH

F

B B

B

H

Hub

D D

A

A

AA

A

AAA

AAA AAA

B B B

A B B

B

BB

B

C CC

C

C

B C

G

G

GG

G GF

AAA AAA

A B BB C

C

G

G GF

Hub

CAT.73.01.T.E

Cutler-HammerB-30October 1998

NEMA Type 3R Outdoor

A 1/2 – – – – 12.7 – – – –

B 1-1/4 1-1/2 1-3/4 2 2-1/2 31.7 38.1 44.5 50.8 63.5

Type CH LoadcentersKnockouts

Code Diameter in Inches Diameter in mm

a 3/4 — — — — 12.7 — — — —

b 1/2 3/4 — — — 12.7 19.0 — — —

c 1/2 — — — — 12.7 — — — —

d 1 1-1/4 1-1/2 2 2-1/2 25.4 31.7 38.1 50.8 63.5

e 1-1/4 1-1/2 2 2-1/2 — 31.7 38.1 50.8 63.5 —

f 3/4 1-1/4 1-1/2 2 — 25.4 31.7 38.1 50.8 —

g 1/2 3/4 1 — — 12.7 19.0 25.4 — —

h 1-1/2 2 2-1/2 — — 38.1 50.8 63.5 — —

i 1/2 3/4 1 1-1/4 1-1/2 12.7 19.0 25.4 31.7 38.1

j 1 1-1/4 1-1/2 — — 25.4 31.7 38.1 — —

k 1-1/4 1-1/2 2 — — 31.7 38.1 50.8 — —

m 3/4 1 1-1/4 1-1/2 2 19.0 25.4 31.7 38.1 50.8

n 3/4 1 1-1/4 1-1/2 — 19.0 25.4 31.7 — —

p 2 2-1/2 — — — 50.8 63.5 — — —

Residential and Commercial Loadcenter Knockouts Dimensions in Inches (mm)

Residential NEMA Type 1 Indoor and NEMA Type 3R Outdoor Enclosures

e e e e

dcc

cc c

b

bi

ccc

c c

bg

bc

b

e

g

b

b

cc

c

g

e

b

e

g

b

b

cc

c

g

e

e e

ee

g g

dc c

ccc

b

bi

c cc

cc

b

g

bc

dcc

cc c

b

bi

ccc

c c

b

g

b

c

b

e

g

b

b

cc

g

e

e e

ee

g g

b

cc

b

e

g

b

b

cc

c

g

e

bc

dc c

ccc

b

bi

c cc

cc

b

g

bc

dcc

cc c

b

bi

ccc

c c

b

g

b

c

j

k

m

g

a

ac

c

f

f

b b b

bbb

p n

ac

cc

a

c

m

cc

c

cg

g

m

k

j

g g g

c

FlushTrim

3/4

c

h

b

Box 8R (CH8R, CH64R)Box 8 (CH8, CH64)

Box P, PMOutdoor Boxes12-42 CKT 225A Max.

Box B Box C, D, E, G, J, K, L

.450 Dia..450 Dia.

.450 Dia..450 Dia.

.450 Dia..450 Dia.

.450 Dia..450 Dia..450 Dia..450 Dia.

Unit Enclosures Knockouts, Type Knockouts

NEMA Type 1 Indoor (Flush and Surface Trims)

Code Diameter in Inches Diameter in mm

A 1/2 – – – – 12.7 – – – –

B 1-1/4 1-1/2 1-3/4 2 2-1/2 31.7 38.1 44.5 50.8 63.5

B

B

B

B

A

A

B

B

B

B B

B A

B B

HUB

NEMA Type 1 – Indoor NEMA Type 3R – Outdoor

October 1998

CAT.73.01.T.E

Cutler-Hammer B-31Type CH LoadcentersTypical Specifications

General

A. The Contractor shall furnish and install loadcenters incorporating circuit breakers of the number, rating and type as specified herein and as shown on the contract drawings.

B. The loadcenter and all components shall be designed, manufactured and tested in accordance with the latest applicable standards of UL and NEMA including:

1. UL 67 – Standards for Panelboards

2. UL 50 – Standards for Cabinetsand Boxes

3. UL 489 – Standards for Molded Case Circuit Breakers

4. Federal Spec ClassificationW-C 375

Qualifications

A. The manufacturer of the load center shall be the manufacturer of the circuit breaker within the load center. All breakers shall be full size.

B. For the equipment specified herein, the manufacturer shall be ISO 9000 certified.

C. The manufacturer of this equipment shall have produced similar electrical equipment for a minimum period of seven (7) years.

Manufacturers

A. Cutler-Hammer

Ratings

A. Loadcenters shall be rated for 240V AC and shall have short circuit ratings as shown on the drawings or as herein scheduled, but not less than 10,000 amperes RMS symmetrical.

B. Breakers shall be full size and a mini-mum of 125 ampere frame. Breakers 10 through 125 ampere trip size shall take up the same pole spacing.

C. Loadcenters shall be labeled witha UL short circuit rating. When series ratings are applied with integral or remote devices, a label shall be pro-vided. Series ratings shall cover all trip ratings of installed frames. It shall state the conditions of the UL series ratings including:

1. Size and type of upstream device.

2. Branch devices that can be used.

3. UL series short circuit rating.

Construction

A. All interiors, with the exception of the branch circuit breakers shall be com-pletely factory assembled with main breakers, main lugs or no main device.

B. Interiors shall be so designed that cir-cuit breakers can be replaced without disturbing adjacent units and without removing the main bus connectors and shall be so designed that circuits may be changed without machining,drilling, or tapping.

C. Physical means must be provided to prevent the installation of more over-current devices than that number for which the enclosure was designed. Full size breakers are required.

Bus

A. Bus bars for the main and cross con-nectors shall be of copper construc-tion in accordance with Underwriters Laboratories, Inc. standards. Bussing shall be braced to 65 kAIC. All connec-tion points shall be tin-plated copper.

B. Neutral bussing shall have a suitable lug for each outgoing feeder requiring a neutral connection of same ampacity as branch.

Wiring/Termination

A. All wire connectors and terminals shall be of the anti-turn solderless type and suitable for copper or aluminum wire of the sizes indicated. All connec-tors shall meet the “Requirements for Wire Connectors and Soldering Lugs” UL486B.

B. All loadcenters where marked shall be suitable for use with 60/75°C rated wire.

Circuit Breakers

A. Circuit breakers shall be molded case type, 3/4-inch wide per pole. Multi-pole circuit breakers shall be of a stack pole design to provide electrical phase isolation and have an internal com-mon trip.

B. Each pole of the circuit breaker will have inverse time delay overload and instantaneous short circuit protection by means of both thermal and mag-netic sensors. Circuit breakers shall be quick-make/quick-break.

C. The circuit breaker calibration shall not be affected by environmental changes in relative humidity. Breakers shall be calibrated after assembly.

D. All circuit breakers shall be operated by a toggle-type handle and multi-pole circuit breakers shall have an internal common trip mechanism. The circuit breakers shall incorporate trip mecha-nisms that are mechanically trip-free from the handle. The handle position shall provide good visual trip indica-tion.

E. Contacts shall be of non-weldingsilver alloy.

F. All branch breaker handles shall beof a different color than the case ofthe breaker.

G. All terminals shall be listed for use with copper or aluminum conductors. Terminals shall be of the box lug design. The terminals shall meet UL 486B requirements and shall besuitable for use with either 60° or75°C wire.

H. Breakers shall be SWD rated and/or HACR rated as required.

I. Arc Fault Interrupting circuit breakers, (AFI), shall be provided on all 15 and 20 ampere single phase 120/240V AC circuits except those indicated as remote controlled breakers. AFI break-ers shall be “Classified for mitigating the effects of arcing faults,” orconforming to UL Standard 1699 and as defined by per article 210-12Section A of the 1999 NEC Code.

Typical Specifications

CAT.73.01.T.E

Cutler-HammerB-32October 1998

Type CH LoadcentersTypical Specifications

Surge Protection Devices

All 120/240V AC single-phase loadcenters shall have surge protection provided by a [Clipper Home Surge Protector device] [plug in surge protection device]

A. The Clipper Home Surge Protector shall be supplied in its own rugged steel enclosure and must be suitable for flush or surface mounting external of the loadcenter. The device shallprovide surge protection for the load-center as well as protection for:two incoming telephone lines and one incoming coaxial cable. The surge pro-tector shall be installed in accordance to NEC Article 280 and be listed under UL1449, (2nd Edition), and UL497A. The units shall be CSA certified and be tested to meet ANIS/IEEE Category B3 and C3 levels. The surge protector shall incorporate a surge plane design to facilitate a common point of grounding for all connected, power, telephone and coaxial incoming con-ductors. The device shall provide, as a minimum, the following protection:

– Up to 39 kA surge current protec-tion per phase for transients on the incoming AC line

– Up to 10 kA surge protection per pair for telephone lines

– Up to 5 kA line to shield (ground) protection for coaxial conductors

OR

A. The surge protection device becapable of plugging onto a maximum of two adjacent spaces in single-phase loadcenter. The device shall provide, as a minimum, up to 10 kA surgecurrent protection per phase fortransients on the incoming AC line.

B. Surge protection devices must be equipped with LEDs to indicate proper functioning of the internal electronics.

Enclosures

A. Loadcenters shall have NEMA 1general purpose or NEMA 3R rain-proof enclosures as indicated on the drawings and shall be surface or flush mounted except where noted.

B. For indoor applications, enclosures shall be rated NEMA 1. Enclosures shall be manufactured from cold rolled code gauge sheet steel having multiple knockouts and painted per paint specification. For outdoor appli-cations, enclosures shall be rated NEMA 3R. Enclosures shall be manu-factured from galvanized steel which shall be painted per the painted as specified. Enclosures shall be of suffi-cient size to meet or exceed NEC wire bending space.

C. The cover shall have an easy adjust-ment feature for flush applications.

D. Boxes shall be factory assembled into a single rigid structure.

E. Provide circuit breaker marking labels and directories.

Finish

F. Boxes and trims shall be finished with a high scratch-resistant aesthetically pleasing finish. The finish shall poly-urethane coating electrostatically applied to a thickness of 1.8 to 2 mils.

G. All loadcenters shall be provided with provisions for accepting a paintableor wall paperable decorator accessory cover. Where loadcenters are installed in living areas, provide manufacturer designed and tested decoratorcover kits.

Warranty

The minimum warranty for Residential loadcenters, breakers and surge protec-tion devices shall be as follows:

– 15 Years on loadcenter, (20 years if provided with loadcenter manufac-turer’s surge protection device).