6
4" CONC. SLAB W/ 6X6, W1.4 x W1.4 WWM PT 2x4 SILL PLATE 1/2" DIA. x 12" A.B. @ 48" O.C. TYP. @ 24" O.C. CORNER @ EA. SIDE OPN'G. 1/2" COUPLER UNDISTURBED EARTH OR 95% MODIFIED DENSITY COMPACT FILL (3) #5 CONT. #4 CONT. 1' - 8" #5 W/ 1'-4" HOOK @ 48" O.C. 2' - 0" 8" MIN. 2x4 @ 16" O.C. 4" CONC. SLAB W/ 6X6, W1.4 x W1.4 WWM SIMPSON CB66 UNDISTURBED EARTH OR 95% MODIFIED DENSITY COMPACT FILL (3) #5 CONT. #4 CONT. 1' - 8" #5 W/ 1'-4" HOOK @ 48" O.C. 2' - 0" 8" MIN. 0' - 8" P.T. 6x6 SYP COL. 0' - 0 1/2" 2x4 @ 16" O.C. 4" CONC. SLAB 1/2" DIA. x 12" A.B. @ 48" O.C. TYP. @ 24" O.C. CORNER @ EA. SIDE OPN'G. 1/2" COUPLER 2' - 0" (3) #5 CONT. TIE ROD SHEATHING PT 2x4 SILL PLATE 1 A B 4 C 2 3 6' - 5" 6' - 2" 6' - 5" 0' - 8" 8' - 4" 6' - 8" 15' - 0" 0' - 8" 19' - 0" 0' - 8" 0' - 8" 4" CONC. SLAB W/ 6x6, W1.4xW1.4 WWM 6 MIL VAPOR BARRIER SMOOTH TROWEL SLOPE DN. 1' - 6" 4" CONC. SLAB W/ 6x6, W1.4xW1.4 WWM 6 MIL VAPOR BARRIER SMOOTH TROWEL 2 S101 2 S101 2 S101 3 S101 4 S101 S101 5 CVR. SEE SPECS. MIN. LAP 30 BAR DIA. CVR. SEE SPECS. MIN. LAP 30 BAR DIA. REINF. PER FND. DETAIL FND. EDGE SEE SPECS. CVR. SEE SPECS. CVR. REINF. PER FND. DETAIL WOOD NOTES 1. WOOD CONSTRUCTION SHALL COMPLY WITH AMERICAN FOREST AND PAPER ASSOCIATION, AF&PA, NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS) & CHAPTER 23 OF FBC. 2. COMPLY WITH "DESIGN SPECIFICATION FOR METAL PLATE CONNECTED TO WOOD TRUSSES." 3. USE LUMBER WITH MINIMUM FB=1050/1200 PSI FOR SINGLE REPETITIVE USE AND A MODULES OF ELASTICITY, "E" OF 1,200,000 PSI (FOR WALLS AND BEAMS). PARALLEL STRAND LUMBER, PSL, AS MANUFACTURED BY TRUS JOIST MACMILLAN CORPORATION OR APPROVED EQUAL IS TO BE USED FOR MANUFACTURED WOOD COMPONENTS AND SHALL HAVE A MINIMUM FB=2900 PSI, E = 2,000,000 PSI, FV -290 PSI (DIMENSIONAL LUMBER SHALL CONFORM TO AMERICAN SOFTWOOD LUMBER STANDARDS PS-20 AND BE S4S AND GRADE STAMPED). ALL TOP PLATE WOOD MEMBERS TO BE DF/SP. 4. AT ALL BUILT-UP WOOD AND/OR ENGINEERED LUMBER BEAMS/TRUSS GIRDER BEARING LOCATIONS, A MINIMUM OF (4) 2X6 STUDS TO BE USED, U.O.N. 5. BEAMS USED AS MULTIPLE ASSEMBLY BEAMS IN LIEU OF SOLID WOOD BEAMS TO BE CONNECTED WITH 3 ROWS OF 16D NAILS AT 12" ON CENTER. 6. ONE PIECE OF 3 1/2" THICK WOOD MEMBER MAY BE SUBSTITUTED FOR TWO PIECES OF 1 3/4". 7. THE INDIVIDUAL STUDS OF BUILT-UP COLUMNS TO BE ADEQUATELY FASTENED TO DEVELOP COMPOSITE ACTION OF THE ASSEMBLY. 8. AT ALL BUILT-UP WOOD COLUMNS USE SPECIFIED ANCHOR TIE DOWNS AT BASE AND TOP OF BUILT-UP COL. BEAMS OR TRUSS GIRDERS BEARING ON BUILT- UP COLUMNS TO BE ANCHORER WITH WOOD TO WOOD UPLIFT CONNECTOR. 9. USE MANUFACTURER'S REQUIRED SIZE AND NUMBER OF NAILS OR BOLTS FOR ANCHOR TIE DOWNS. HURRICANE CLIPS AND ALL CONNECTORS. ALL HURRICANE CLIPS, TIE-DOWNS AND FASTENERS TO BE STAINLESS STEEL. SIMPSON PRODUCTS THAT CANNOT BE PROVIDED IN STAINLESS STEEL, MAY BE Z-MAX GALVANIZED. 10. 5/8" PLYWOOD ROOF SHEATHING APA RATED 24/16 EXPOSURE 1 TO BE NAILED TO SUPPORTED MEMBERS WITH 10D NAILS AT 6" ON CENTER INFIELD, 3" ON CENTER ALONG ALL PANEL EDGES. 11. 5/8" PLYWOOD WALL SHEATHING TO BE NAILED TO WALL STUDS WITH 10D NAILS AT 6" ON CENTER, 3" ON CENTER ALONG THE PANEL EDGES. 12. GYPSUM WALL SHEATHING AT EXTERIOR AND LOAD BEARING WALLS TO BE SECURED TO STUDS WITH DRYWALL NAILS AT 7" ON CENTER AND 4" ON CENTER ALONG THE PANEL EDGES. 13. PROVIDE CONTINUAL LATERAL BRACING AND/OR BLOCKING BETWEEN CHORDS OF TRUSSES AS REQUIRED OR AS NOTED BY TRUSS MANUFACTURER TO ADEQUATELY TRANSFER LAODS TO SHEAR WALLS. 14. CONTRACTOR TO VERIFY THAT HURRICANE CLIPS/TIE DOWNS SHOWN WILL RESIST WIND UPLIFT FROM ROOF TRUSSES. IF UPLIFT VALUE FROM ROOF TRUSS MANUFACTURER EXCEEDS CAPACITY OF THE HURRICANE CLIP/TIE DOWN, THE CONTRACTOR SHALL PROVIDE A CONNECTOR TO RESIST THE UPLIFT LOADS. ALL HURRICANE CLIPS AND STRAPS TO BE STAINLESS STEEL PER MANUFACTURER (SIMPSON-SST300, TYPE 316-L. 15. PLACE FLAT STRAPPING BETWEEN STUDS AT ENDS OF ALL BEAM BEARING LOCATIONS. MIN 1 1/4"X30"X16 GA. FLAT STRIP WITH TWENTY-FOUR 10D NAILS TO BE PLACED AT ENDS OF BUILT-UP WOOD BEAMS. 16. ANCHOR BOLTS TO BE 5/8"X16" LONG WITH 2" SQUARE WASHERS, SPACED 32" ON CENTER U.O.N. FIRST ANCHOR BOLT IS TO BE PLACED A MAXIMUM OF 4" FROM EACH CORNER. 17. WOOD IN CONTACT WITH CONCRETE OR MASONRY WALL SHALL BE PROTECTED OR PRESSURE TREATED IN ACCORDANCE WITH AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS. 18. STANDARD U.S.S. WASHERS SHALL BE USED BETWEEN WOOD AND BOLT HEADS AND NUTS. BOLTS AND SCREWS SHALL BE ASTM A-307, ALL TO BE HOT DIPPED GALVANIZED. ALL BOLTS/FASTENERS EXPOSED TO WEATHER TO BE 316 STAINLESS STEEL. 19. WOOD TRUSSES AND CONNECTIONS ARE TO BE DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. METAL PLATE CONNECTED TRUSSES SHALL COMPLY WITH THE SPECIFICATIONS FOR DESIGN OF LUMBER AND ITS FASTENINGS, TRUSS PLATE INSTITUTE DESIGN SPECIFICATIONS & THE LATEST EDITION OF FLORIDA BUILDING CODE. 20. ERECTION, BRACING AND HANDLING OF TRUSSES SHALL BE PERFORMED IN ACCORDANCE WITH REQUIREMENTS BY TRUSS PLATE INSTITUTE. 21. LOCATIONS WHERE THE RIGID CEILING IS NOT PERMANENTLY SECURED TO THE BOTTOM CHORD OF TRUSS, 2X4 MEMBERS AT 4'-0" ON CENTER SHALL BE SECURED PERPENDICULAR TO THE BOTTOM CHORD. 22. LOCATIONS WHERE ROOF SHEATHING IS NOT PERMANENTLY SECURED TO THE BOTTOM CHORD OF TRUSS, 2X4 MEMBERS AT 2'-0" ON CENTER SHALL BE SECURED PERPENDICULAR TO THE BOTTOM CHORD. 23. WANES ARE NOT ACCEPTABLE IN EXPOSED MATERIALS. 24. WHERE PRESSURE TREATED FRAMING IS REQUIRED, FRAMING SHALL BE PRESSURE TREATED USING NON, CCA METHODS, PRESSURE TREATING TO BE ACQ OR EQUIVALENT. MINIMUM NAILING SCHEDULE : 1. JOIST OR RAFTERS TO SIDES OF STUDS 3-16d 8-INCH JOIST OR LESS 1-16d FOR EACH ADDITIONAL 4 INCHES IN DEPTH OF JOIST 2-8d 2. BRIDGING TO JOIST, TOENAIL EACH END a. BLOCKING BETWEEN JOISTS OR RAFTERS - TO JOIST OR RAFTERS - TOENAILS EACH SIDE, EACH END 2-10d b. BLOCKING BETWEEN STUDS, EACH END 2-10d toenails or 2-16d 3. SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL 16d at 16" o.c. 4. TOP PLATE TO STUD, END NAIL 2-16d 5. STUD TO SOLE PLATE 4-8, toenail or 2-16d, end nail 6. DOUBLE STUDS, FACE NAIL 16d at 24" o.c. 7. DOUBLED TOP PLATES, FACE NAIL 16d at 16" o.c. 8. TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL 2-16d 9. CEILING JOISTS TO PLATE, TOENAIL 3-8d 10. CONTINUOUS HEADER TO STUD, TOENAIL 4-8d 11. CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL 3-16d 12. CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL 3-16d 13. JOIST OR RAFTERS AT ALL BEARINGS - TOENAILS, EACH SIDE 2-10d 14. 1" BRACE TO EACH STUD AND PLATE, FACE NAIL 2-8d 15. BUILT-UP CORNER STUDS 16d at 24" o.c. SILL BOLT REQUIREMENTS 1. PROVIDE A MINIMUM SILL BOLT EMBEDMENT OF 7" BELOW FINISH FLOOR OR 2. PROVIDE AN ADDITIONAL SILL BOLT 6 INCHES FROM EACH END OF EACH 3. WHERE SILL PLATES ARE BORED OR NOTCHED IN EXCESS OF 1/3 OF THE 4. SET ALL SILL BOLTS WITH A SETTING TEMPLATE BEFORE PLACING 5. PROVIDE A MINIMUM SILL BOLT PROJECTION ABOVE THE CONCRETE AS SHOWN TOP OF CURB. PIECE OF SILL PLATE. SILL PLATE WIDTH, PROVIDE ADDITIONAL SILL BOLTS 6 INCHES EACH SIDE OF BORE OR NOTCH. CONCRETE. STABBING OR PUSHING OF SILL BOLTS INTO WET CONCRETE IS EXPRESSLY PROHIBITED. ON DETAIL C. BUTT END OR END OF SILL PLATE 6" 6" 6" 3" MIN. WHERE DRYPACK OCCURS TOP OF CONC. 2x NAILER, TYP. U.N.O. BORE OR NOTCH "W" TYPICAL SILL PLATE ELEVATION PLAN VIEW MINIMUM SILL BOLT PROJECTION A C B 2 1 a a a 3 2 2 2 1 3 2 2 a 5 4 5 5 a a 5 HT OKEECHOBEE BATTLEFIELD HISTORIC STATE PARK DAY USE RESTROOM OKEECHOBEE, FLORIDA SHEET TITLE PROJECT TITLE J. SCOTT FRANCE FL PE NO. 63015 CONSULTANT: FRANCE ENGINEERING, LLC. 2920 CALLAWAY ROAD TALLAHASSEE, FLORIDA 32312 p.: 850.386.7100 - www.francepe.com CA NO. 30561 DESIGNER: J.S. FRANCE DRAWN BY: JSF REVIEWED BY: J.S. FRANCE ISSUE DATE: COMP. FILE No.: STATE PROJECT No.: 14--.001 60928C SYMBOL REVISION DATE SYMBOL REVISION DATE A B A B Department of Environmental Protection Division of Recreation and Parks Bureau of Design and Construction 3450 Thomasville Rd., Tallahassee, FL 32309 (850) 488-5372 SHEET NO. ISSUED FOR REVIEW FOUNDATION PLAN & DETAILS S101 11-14-2014 3/4" = 1'-0" 2 FOUNDATION PERIMETER DETAIL 3/4" = 1'-0" 3 FOUNDATION COLUMN DETAIL 3/4" = 1'-0" 4 FOUNDATION THICKENED SLAB DETAIL 1/2" = 1'-0" 1 FOUNDATION PLAN 3/4" = 1'-0" 5 CORNER REBAR DETAIL APPLICABLE CODES FLORIDA BUILDING CODE - EXISTING (FBC-E) 2010 EDITION AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE 7) 2010 EDITION AMERICAN CONCRETE INSTITUTE (ACI 318) 2008 EDITION AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) 3RD EDITION DESIGN LOADS ROOF DEAD LOAD 12 PSF ROOF LIVE LOAD 20 PSF WIND LOAD NOTES BUILDING ENCLOSURE PARTIAL BUILDING END ZONE "a" 3 FEET EXPOSURE "C" INTERNAL PRESSURE +/- 0.55 RISK CATEGORY I WINDLOAD Vult = 140 MHP COMPONENTS & CLADDING ROOF (ULTIMATE) ROOF 10 SF 50 SF 100 SF ZONE 1 -45 PSF -40 PSF -37 PSF ZONE 2 -53 PSF -48 PSF -45 PSF ZONE 3 -53 PSF -48 PSF -45 PSF ZONES ALL 41 PSF 41 PSF 41 PSF CONCRETE NOTES 1. ALL CONCRETE SHALL HAVE A MINIMUM 28 DAY CYLINDER COMPRESSIVE STRENGTH lf'c) OF 3000 PSI. 2. REINFORCING BARS: ASTM A-615, GRADE 40 OR 60. 3. REINFORCING BAR SPLICES SHALL BE LAPPPED 24" MIN. OR 30 Db WHICHEVER IS LARGER. 4. THE MINIMUM PROTECTIVE CONCRETE COVER FOR REINFORCING BARS SHALL BE AS FOLLOWS: CAST AGAINST & PERMANENTLY EXPOSED TO EARTH, 3" EXPOSED TO EARTH & WEATHER, 2", NOT EXPOSED TO EARTH OR WEATHER OR IN CONTACT WITH GROUND, 1 1/2" 5. COMPACT SOIL TO 95% MODIFIED PROCTOR. 6. MINIMUM SOIL CAPACITY OF 2000 PSF. 7. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. COMPONENTS & CLADDING WALL (ULTIMATE) WALL 10 SF 50 SF 100 SF ZONE 4 -49 PSF -45 PSF -43 PSF ZONE 5 -60 PSF -52 PSF -48 PSF

C:Userssa002Desktopsa+ REVIT FILESTitle ...€¦ · modules of elasticity, ... conform to american softwood lumber standards ps-20 and be s4s and grade stamped). ... t l e f i e l

  • Upload
    buiphuc

  • View
    213

  • Download
    1

Embed Size (px)

Citation preview

4" CONC. SLAB W/ 6X6,W1.4 x W1.4 WWM

PT 2x4 SILL PLATE

1/2" DIA. x 12" A.B.@ 48" O.C. TYP.@ 24" O.C. CORNER@ EA. SIDE OPN'G.

1/2" COUPLER

UNDISTURBED EARTH OR95% MODIFIED DENSITYCOMPACT FILL

(3) #5 CONT.

#4 CONT.

1' - 8"

#5 W/ 1'-4" HOOK@ 48" O.C.

2' -

0"

8" M

IN.

2x4 @ 16" O.C.

4" CONC. SLAB W/ 6X6,W1.4 x W1.4 WWM

SIMPSON CB66

UNDISTURBED EARTH OR95% MODIFIED DENSITYCOMPACT FILL

(3) #5 CONT.

#4 CONT.

1' - 8"

#5 W/ 1'-4" HOOK@ 48" O.C.

2' -

0"

8" M

IN.

0' - 8"

P.T. 6x6SYP COL.

0' -

0 1/

2"

2x4 @ 16" O.C.

4" CONC. SLAB

1/2" DIA. x 12" A.B.@ 48" O.C. TYP.@ 24" O.C. CORNER@ EA. SIDE OPN'G.

1/2" COUPLER

2' -

0"

(3) #5 CONT.

TIE ROD

SHEATHING

PT 2x4 SILL PLATE

1

A

B

4

C

2 3

6' - 5" 6' - 2" 6' - 5"

0' - 8"

8' -

4"6'

- 8"

15' -

0"

0' -

8"

19' - 0"

0' - 8"

0' -

8"

4" CONC. SLAB W/6x6, W1.4xW1.4 WWM

6 MIL VAPOR BARRIERSMOOTH TROWEL

SLO

PE D

N.

1' -

6"

4" CONC. SLAB W/6x6, W1.4xW1.4 WWM

6 MIL VAPOR BARRIERSMOOTH TROWEL

2S101

2S101

2S101

3S101

4S101

S1015

CVR

. SEE

SPE

CS.

MIN

. LAP

30 B

AR D

IA.

CVR. SEE SPECS.

MIN. LAP

30 BAR DIA.

REINF. PERFND. DETAIL

FND. EDGE

SEE SPECS.CVR.

SEE

SPEC

S .C

VR.

REINF. PERFND. DETAIL

WOOD NOTES

1. WOOD CONSTRUCTION SHALL COMPLY WITH AMERICAN FOREST AND PAPER ASSOCIATION, AF&PA, NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS) & CHAPTER 23 OF FBC.

2. COMPLY WITH "DESIGN SPECIFICATION FOR METAL PLATE CONNECTED TO WOOD TRUSSES."

3. USE LUMBER WITH MINIMUM FB=1050/1200 PSI FOR SINGLE REPETITIVE USE AND A MODULES OF ELASTICITY, "E" OF 1,200,000 PSI (FOR WALLS AND BEAMS). PARALLEL STRAND LUMBER, PSL, AS MANUFACTURED BY TRUS JOIST MACMILLAN CORPORATION OR APPROVED EQUAL IS TO BE USED FOR MANUFACTURED WOOD COMPONENTS AND SHALL HAVE A MINIMUM FB=2900 PSI, E = 2,000,000 PSI, FV -290 PSI (DIMENSIONAL LUMBER SHALL CONFORM TO AMERICAN SOFTWOOD LUMBER STANDARDS PS-20 AND BE S4S AND GRADE STAMPED). ALL TOP PLATE WOOD MEMBERS TO BE DF/SP.

4. AT ALL BUILT-UP WOOD AND/OR ENGINEERED LUMBER BEAMS/TRUSS GIRDER BEARING LOCATIONS, A MINIMUM OF (4) 2X6 STUDS TO BE USED, U.O.N.

5. BEAMS USED AS MULTIPLE ASSEMBLY BEAMS IN LIEU OF SOLID WOOD BEAMS TO BE CONNECTED WITH 3 ROWS OF 16D NAILS AT 12" ON CENTER.

6. ONE PIECE OF 3 1/2" THICK WOOD MEMBER MAY BE SUBSTITUTED FOR TWO PIECES OF 1 3/4".7. THE INDIVIDUAL STUDS OF BUILT-UP COLUMNS TO BE ADEQUATELY FASTENED TO DEVELOP COMPOSITE ACTION OF THE ASSEMBLY.

8. AT ALL BUILT-UP WOOD COLUMNS USE SPECIFIED ANCHOR TIE DOWNS AT BASE AND TOP OF BUILT-UP COL. BEAMS OR TRUSS GIRDERS BEARING ON BUILT- UP COLUMNS TO BE ANCHORER WITH WOOD TO WOOD UPLIFT CONNECTOR.

9. USE MANUFACTURER'S REQUIRED SIZE AND NUMBER OF NAILS OR BOLTS FOR ANCHOR TIE DOWNS. HURRICANE CLIPS AND ALL CONNECTORS. ALL HURRICANE CLIPS, TIE-DOWNS AND FASTENERS TO BE STAINLESS STEEL. SIMPSON PRODUCTS THAT CANNOT BE PROVIDED IN STAINLESS STEEL, MAY BE Z-MAX GALVANIZED.

10. 5/8" PLYWOOD ROOF SHEATHING APA RATED 24/16 EXPOSURE 1 TO BE NAILED TO SUPPORTED MEMBERS WITH 10D NAILS AT 6" ON CENTER INFIELD, 3" ON CENTER ALONG ALL PANEL EDGES.

11. 5/8" PLYWOOD WALL SHEATHING TO BE NAILED TO WALL STUDS WITH 10D NAILS AT 6" ON CENTER, 3" ON CENTER ALONG THE PANEL EDGES.

12. GYPSUM WALL SHEATHING AT EXTERIOR AND LOAD BEARING WALLS TO BE SECURED TO STUDS WITH DRYWALL NAILS AT 7" ON CENTER AND 4" ON CENTER ALONG THE PANEL EDGES.

13. PROVIDE CONTINUAL LATERAL BRACING AND/OR BLOCKING BETWEEN CHORDS OF TRUSSES AS REQUIRED OR AS NOTED BY TRUSS MANUFACTURER TO ADEQUATELY TRANSFER LAODS TO SHEAR WALLS.

14. CONTRACTOR TO VERIFY THAT HURRICANE CLIPS/TIE DOWNS SHOWN WILL RESIST WIND UPLIFT FROM ROOF TRUSSES. IF UPLIFT VALUE FROM ROOF TRUSS MANUFACTURER EXCEEDS CAPACITY OF THE HURRICANE CLIP/TIE DOWN, THE CONTRACTOR SHALL PROVIDE A CONNECTOR TO RESIST THE UPLIFT LOADS. ALL HURRICANE CLIPS AND STRAPS TO BE STAINLESS STEEL PER MANUFACTURER (SIMPSON-SST300, TYPE 316-L.

15. PLACE FLAT STRAPPING BETWEEN STUDS AT ENDS OF ALL BEAM BEARING LOCATIONS. MIN 1 1/4"X30"X16 GA. FLAT STRIP WITH TWENTY-FOUR 10D NAILS TO BE PLACED AT ENDS OF BUILT-UP WOOD BEAMS.

16. ANCHOR BOLTS TO BE 5/8"X16" LONG WITH 2" SQUARE WASHERS, SPACED 32" ON CENTER U.O.N. FIRST ANCHOR BOLT IS TO BE PLACED A MAXIMUM OF 4" FROM EACH CORNER.

17. WOOD IN CONTACT WITH CONCRETE OR MASONRY WALL SHALL BE PROTECTED OR PRESSURE TREATED IN ACCORDANCE WITH AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS.

18. STANDARD U.S.S. WASHERS SHALL BE USED BETWEEN WOOD AND BOLT HEADS AND NUTS. BOLTS AND SCREWS SHALL BE ASTM A-307, ALL TO BE HOT DIPPED GALVANIZED. ALL BOLTS/FASTENERS EXPOSED TO WEATHER TO BE 316 STAINLESS STEEL.

19. WOOD TRUSSES AND CONNECTIONS ARE TO BE DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. METAL PLATE CONNECTED TRUSSES SHALL COMPLY WITH THE SPECIFICATIONS FOR DESIGN OF LUMBER AND ITS FASTENINGS, TRUSS PLATE INSTITUTE DESIGN SPECIFICATIONS & THE LATEST EDITION OF FLORIDA BUILDING CODE.

20. ERECTION, BRACING AND HANDLING OF TRUSSES SHALL BE PERFORMED IN ACCORDANCE WITH REQUIREMENTS BY TRUSS PLATE INSTITUTE.

21. LOCATIONS WHERE THE RIGID CEILING IS NOT PERMANENTLY SECURED TO THE BOTTOM CHORD OF TRUSS, 2X4 MEMBERS AT 4'-0" ON CENTER SHALL BE SECURED PERPENDICULAR TO THE BOTTOM CHORD.

22. LOCATIONS WHERE ROOF SHEATHING IS NOT PERMANENTLY SECURED TO THE BOTTOM CHORD OF TRUSS, 2X4 MEMBERS AT 2'-0" ON CENTER SHALL BE SECURED PERPENDICULAR TO THE BOTTOM CHORD.

23. WANES ARE NOT ACCEPTABLE IN EXPOSED MATERIALS.

24. WHERE PRESSURE TREATED FRAMING IS REQUIRED, FRAMING SHALL BE PRESSURE TREATED USING NON, CCA METHODS, PRESSURE TREATING TO BE ACQ OR EQUIVALENT.

MINIMUM NAILING SCHEDULE:

1. JOIST OR RAFTERS TO SIDES OF STUDS 3-16d8-INCH JOIST OR LESS 1-16dFOR EACH ADDITIONAL 4 INCHES IN DEPTH OF JOIST 2-8d

2. BRIDGING TO JOIST, TOENAIL EACH ENDa. BLOCKING BETWEEN JOISTS OR RAFTERS - TO JOIST OR RAFTERS - TOENAILS EACH SIDE, EACH END 2-10db. BLOCKING BETWEEN STUDS, EACH END 2-10d toenails or 2-16d

3. SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL 16d at 16" o.c.4. TOP PLATE TO STUD, END NAIL 2-16d5. STUD TO SOLE PLATE 4-8, toenail or 2-16d, end nail6. DOUBLE STUDS, FACE NAIL 16d at 24" o.c.7. DOUBLED TOP PLATES, FACE NAIL 16d at 16" o.c.8. TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL 2-16d9. CEILING JOISTS TO PLATE, TOENAIL 3-8d10. CONTINUOUS HEADER TO STUD, TOENAIL 4-8d11. CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL 3-16d12. CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL 3-16d13. JOIST OR RAFTERS AT ALL BEARINGS - TOENAILS, EACH SIDE 2-10d14. 1" BRACE TO EACH STUD AND PLATE, FACE NAIL 2-8d15. BUILT-UP CORNER STUDS 16d at 24" o.c.

SILL BOLT REQUIREMENTS1. PROVIDE A MINIMUM SILL BOLT EMBEDMENT OF 7" BELOW FINISH FLOOR OR

2. PROVIDE AN ADDITIONAL SILL BOLT 6 INCHES FROM EACH END OF EACH

3. WHERE SILL PLATES ARE BORED OR NOTCHED IN EXCESS OF 1/3 OF THE

4. SET ALL SILL BOLTS WITH A SETTING TEMPLATE BEFORE PLACING

5. PROVIDE A MINIMUM SILL BOLT PROJECTION ABOVE THE CONCRETE AS SHOWN

TOP OF CURB.

PIECE OF SILL PLATE.

SILL PLATE WIDTH, PROVIDE ADDITIONAL SILL BOLTS 6 INCHES EACH SIDEOF BORE OR NOTCH.

CONCRETE. STABBING OR PUSHING OF SILL BOLTS INTO WET CONCRETE ISEXPRESSLY PROHIBITED.

ON DETAIL C.

BUTT END OR ENDOF SILL PLATE

6"

6"6"

3" MIN. WHEREDRYPACK OCCURS

TOP OF CONC.

2x NAILER, TYP.U.N.O.

BORE OR NOTCH

"W"

TYPICAL SILL PLATE ELEVATION

PLAN VIEW

MINIMUM SILL BOLT PROJECTION

A

C

B

2 1

aaa

3

2

2

21

3

2

2

a

54

5 5

a

a

5 HT

OKE

ECH

OBE

E BA

TTL E

FIEL

D H

ISTO

RIC

STA

TE P

ARK

DAY

USE

RE S

T RO

OM

OK E

E CH

OB E

E , F

LOR

IDA

SH

EET

TIT L

E

PR

OJE

CT

T ITL

E

J. S

CO

TT F

RAN

CE

FL P

E N

O. 6

3015

CO

NSU

LTA N

T:FR

ANCE

E NGI

NEER

ING,

LLC.

2920

CAL

LAWA

Y ROA

DT A

LLAH

ASS E

E, FL

ORID

A 32

312

p.: 8

50.3

86.71

00 -

www .

franc

epe .c

omCA

NO.

305 6

1

DE S

IGN

E R:

J.S .

FR

ANC

E

DR

AWN

BY:

JSF

REV

IEW

ED B

Y:J.

S . F

RAN

CE

ISSU

E D

ATE:

CO

MP.

FIL

E N

o.:

STA

TE P

RO

JEC

T N

o.:

14- -.

001

609 2

8C

SYM

BOL

REV

ISIO

ND

ATE

SYM

BOL

REV

ISIO

ND

ATE

A B

A B

De partm

e nt of Environmental Protec tion

Division of Re creation and Parks

Bure au of Design and Construc tion

3450 Thomasvill e Rd., Tallahasse e, FL 32309 (850) 488-5372

SHEET NO.

I SS U

E D F

OR

RE V

I EW

FOU

ND

A TIO

N P

L AN

& D

ETAI

L S

S101

11-1

4-20

14

3/4" = 1'-0"2 FOUNDATION PERIMETER DETAIL 3/4" = 1'-0"3 FOUNDATION COLUMN DETAIL

3/4" = 1'-0"4 FOUNDATION THICKENED SLAB DETAIL 1/2" = 1'-0"1 FOUNDATION PLAN

3/4" = 1'-0"5 CORNER REBAR DETAIL

APPLICABLE CODESFLORIDA BUILDING CODE - EXISTING (FBC-E) 2010 EDITIONAMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE 7) 2010 EDITIONAMERICAN CONCRETE INSTITUTE (ACI 318) 2008 EDITIONAMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) 3RD EDITION

DESIGN LOADSROOF DEAD LOAD 12 PSFROOF LIVE LOAD 20 PSF

WIND LOAD NOTESBUILDING ENCLOSURE PARTIALBUILDING END ZONE "a" 3 FEETEXPOSURE "C"INTERNAL PRESSURE +/- 0.55RISK CATEGORY IWINDLOAD Vult = 140 MHP

COMPONENTS & CLADDING ROOF (ULTIMATE)ROOF 10 SF 50 SF 100 SF

ZONE 1 -45 PSF -40 PSF -37 PSFZONE 2 -53 PSF -48 PSF -45 PSFZONE 3 -53 PSF -48 PSF -45 PSFZONES ALL 41 PSF 41 PSF 41 PSF

CONCRETE NOTES1. ALL CONCRETE SHALL HAVE A MINIMUM 28 DAY CYLINDER COMPRESSIVE

STRENGTH lf'c) OF 3000 PSI.2. REINFORCING BARS: ASTM A-615, GRADE 40 OR 60.3. REINFORCING BAR SPLICES SHALL BE LAPPPED 24" MIN. OR 30 Db

WHICHEVER IS LARGER.4. THE MINIMUM PROTECTIVE CONCRETE COVER FOR REINFORCING BARS

SHALL BE AS FOLLOWS: CAST AGAINST & PERMANENTLY EXPOSED TOEARTH, 3" EXPOSED TO EARTH & WEATHER, 2", NOT EXPOSED TO EARTHOR WEATHER OR IN CONTACT WITH GROUND, 1 1/2"

5. COMPACT SOIL TO 95% MODIFIED PROCTOR.6. MINIMUM SOIL CAPACITY OF 2000 PSF.7. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.

COMPONENTS & CLADDING WALL (ULTIMATE)WALL 10 SF 50 SF 100 SF

ZONE 4 -49 PSF -45 PSF -43 PSFZONE 5 -60 PSF -52 PSF -48 PSF

12

4

2x4 @ 16" O.C.

4" CONC. SLAB

PT 2x4 SILL PLATE

PT 2x4 DBL. TOPPLATE

SIMPSON H14@ EA. TRUSS

1/2" DIA. x 12" A.B.@ 48" O.C. TYP.@ 24" O.C. CORNER@ EA. SIDE OPN'G.

1/2" CDX PLY. W/10d x 2 1/4"@ 4" O.C. EDGE@ 6" O.C. FIELD@ 4" O.C. PERIMETER

1/2" CDX PLY. W/10d x 2 1/4"@ 4" O.C. EDGE@ 6" O.C. FIELD@ 4" O.C. PERIMETER

PRE-ENGINEEREDTRUSSES @ 24" O.C.

2' O.H.

SEE ARCH.FOR FINISH

1/2" DIA. ALL THREADROD @ EA. A.B.

1/2" COUPLER

SLOPE GRADE FORPOSITIVE DRAINAGE

2x BLOCKING

3x3x1/4 PLATE WASHERW/ SIMPSON RTU NUT

SEE SHT. S101FOR FND. DETAIL

12

4

SIMPSON H14@ EA. TRUSS

SIMPSON CB66

1/2" CDX PLY. W/10d x 2 1/4"@ 4" O.C. EDGE@ 6" O.C. FIELD@ 4" O.C. PERIMETER

PRE-ENGINEEREDTRUSSES @ 24" O.C.

2' O.H.

SEE ARCH.FOR FINISH

SLOPE GRADE FORPOSITIVE DRAINAGE

SEE SHT. S101FOR FND. DETAIL

P.T. 6x6SYP COL.

SIMPSON ECCQ46SDS2.5

(2) 2x12

OFF

SET

0' -

0 1/

2"

FINISH SEE ARCH.

2x4 @ 16" O.C.

4" CONC. SLAB

PT 2x4 DBL. TOPPLATE

SIMPSON H10@ EA. TRUSS

1/2" DIA. x 12" A.B.@ 48" O.C. TYP.@ 24" O.C. CORNER@ EA. SIDE OPN'G.

1/2" CDX PLY. W/10d x 2 1/4"@ 4" O.C. EDGE@ 6" O.C. FIELD@ 4" O.C. PERIMETER

PRE-ENGINEEREDTRUSSES @ 24" O.C.

SEE ARCH.FOR FINISH

1/2" DIA. ALL THREADROD @ EA. A.B.

1/2" COUPLER

2x BLOCKING

3x3x1/4 PLATE WASHERW/ SIMPSON RTU NUT

SEE SHT. S101FOR FND. DETAIL

PT 2x4 SILL PLATE

1

A

B

4

C

2 3

6' - 5" 6' - 2" 6' - 5"

8' -

4"6'

- 8"

15' -

0"

19' - 0"

EXT. SHEAR WALLTYPICAL

VERT. ALL THREAD RODTIE DOWN, TYP.

6x6 COL.(4) TYPICAL

1' - 6"

9' - 6"

1' - 6"

2' -

0"

2' - 6"

6' - 1"

2' - 6"

6' - 1"

2' -

0"

HB HB HB HB

HB

HB

HB HB HB

3S102

4S102

2S102

2S102

2S102

TYP.

1' - 6"

TYP.

1' -

6"

SIMPSON CCQ46SDS2.5TYPICAL

1/2" THRU BOLT W/ WASHERSCOUNTERSINK BOLT ENDSTYPICAL

1/2" THRU BOLT W/ WASHERSCOUNTERSINK BOLT ENDSTYPICAL

PT 6X6 COL.TYP.

4x6 KNEE BRACETYPICAL

2x12 W/ 1/2" PLY. CONT.FASTENED W/ (2) ROWS10d GALV. NAILS @ 12" O.C.

TYP.

1' - 0"

0' -

2"0'

- 2"

TIE ROD

(2) 2x10 W/1/2" PLY.HEADER BEAM

TOP PLATE

SIMPSON LSTA12@ HEADERS &

LSTA 21 @ BEAMS

(1) JACKSTUD

MAX. 8"

STUD PACK

MIN.

0' - 6"#2 S.Y.PTOP PLATE

SPLICE OVER STUDSTAGGER TOP & BOTT.2x SPLICES

1/4" THK. x 12" S.S. PLATEW/ (12) #14 SS SCREWS

OVER SPLICE

OKE

ECH

OBE

E BA

TTL E

FIEL

D H

ISTO

RIC

STA

TE P

ARK

DAY

USE

RE S

T RO

OM

OK E

E CH

OB E

E , F

LOR

IDA

SH

EET

TIT L

E

PR

OJE

CT

T ITL

E

J. S

CO

TT F

RAN

CE

FL P

E N

O. 6

3015

CO

NSU

LTA N

T:FR

ANCE

E NGI

NEER

ING,

LLC.

2920

CAL

LAWA

Y ROA

DT A

LLAH

ASS E

E, FL

ORID

A 32

312

p.: 8

50.3

86.71

00 -

www .

franc

epe .c

omCA

NO.

305 6

1

DE S

IGN

E R:

J.S .

FR

ANC

E

DR

AWN

BY:

JSF

REV

IEW

ED B

Y:J.

S . F

RAN

CE

ISSU

E D

ATE:

CO

MP.

FIL

E N

o.:

STA

TE P

RO

JEC

T N

o.:

14- -.

001

609 2

8C

SYM

BOL

REV

ISIO

ND

ATE

SYM

BOL

REV

ISIO

ND

ATE

A B

A B

De partm

e nt of Environmental Protec tion

Division of Re creation and Parks

Bure au of Design and Construc tion

3450 Thomasvill e Rd., Tallahasse e, FL 32309 (850) 488-5372

SHEET NO.

I SS U

E D F

OR

RE V

I EW

WA L

L SE

CT I

ON

& D

E TA I

LS

S102

11-1

4-20

14

3/4" = 1'-0"2 01 EXT. WALL SECTION 3/4" = 1'-0"3 02 COLUMN SECTION

3/4" = 1'-0"4 03 EXT. WALL SECTION 1/2" = 1'-0"1 TIE DOWN PLAN

3/4" = 1'-0"5 PORCH BEAM DETAIL 1 1/2" = 1'-0"6 TYPICAL HEADER BEAM DETAIL

1 1/2" = 1'-0"7 TOP PLATE NAILING DETAIL

SEE DETAIL 2/S103 SEE DETAIL 2/S103

1

1

A

B

4

4

C

2 3

SIMPSON H14 OR EQUAL

SIMPSON LGT2SEE DETAIL 08

GIR

DER

TR

USS

GIR

DER

TR

USS

HIP

HIP

RIDGE

HIP

HIP

SIMPSON HCP2 OR EQUAL@ WALL ENDS & BEAMCORNERS

4:12

4:12 4:12

4:12

T/ BRG WALL BLKNG W/ SIMPSON RBC OR EQUAL17' - 3 1/4"

(2) 2x12

(2) 2

x12

(2) 2

x12

SIMPSON MGTSEE DETAIL XX

SIM

PSO

N H

14 O

R E

QU

AL

SIMPSON MGT2SEE DETAIL 09

SIMPSON LGT2SEE DETAIL 08

SIMPSON MGT2SEE DETAIL 09

COLUMN

SIMPSON CB66OR EQUAL

3000 PSI, MIN.

COLUMN

SIMPSON CBSQ OR EQUAL

TOP PLATE

TRUSS OR RAFTER

H14 CLIPPLACE NAIL IN EA. HOLE

SEE ARCH.FOR FINISH

P.T. 6x6SYP COL.

SIMPSON ECCQ46SDS2.5

PT (2) 2x12

2x12 PT

SIMPSON TS12

2x STUDPACK

2x12 PT

SIMPSON LSTA21OR EQUAL

SIMPSON LSTA21OR EQUAL

FIEL

D S

PAC

ING

NO

TE 3

EDGESPACINGNOTE 2

PERIMETERSPACINGNOTE 1.

NOTE:

1. FOR SHEATHING PERMITER SPACING TO BE 4" O.C.

2. FOR PLY. SHEATHING EDGE SPACING TO BE 4" O.C.

3. FOR PLY. SHEATHING FIELD SPACING TO BE 4" O.C.

ROOF SHEATHING NAILING SCHEDULE

FIEL

D S

PAC

ING

NO

TE 3

EDGESPACINGNOTE 2

PERIMETERSPACINGNOTE 1.

NOTE:

1. FOR SHEATHING PERMITER SPACING TO BE 4" O.C.

2. FOR PLY. SHEATHING EDGE SPACING TO BE 4" O.C.

3. FOR PLY. SHEATHING FIELD SPACING TO BE 4" O.C.

WALL SHEATHING NAILING SCHEDULE

TRUSS GIRDER

SIMPSON LGTOR EQUAL

(2) 2x12 BEAM

TRUSS GIRDER

SIMPSON MGTOR EQUAL

STUD PACK

TIE ROD

OKE

ECH

OBE

E BA

TTL E

FIEL

D H

ISTO

RIC

STA

TE P

ARK

DAY

USE

RE S

T RO

OM

OK E

E CH

OB E

E , F

LOR

IDA

SH

EET

TIT L

E

PR

OJE

CT

T ITL

E

J. S

CO

TT F

RAN

CE

FL P

E N

O. 6

3015

CO

NSU

LTA N

T:FR

ANCE

E NGI

NEER

ING,

LLC.

2920

CAL

LAWA

Y ROA

DT A

LLAH

ASS E

E, FL

ORID

A 32

312

p.: 8

50.3

86.71

00 -

www .

franc

epe .c

omCA

NO.

305 6

1

DE S

IGN

E R:

J.S .

FR

ANC

E

DR

AWN

BY:

JSF

REV

IEW

ED B

Y:J.

S . F

RAN

CE

ISSU

E D

ATE:

CO

MP.

FIL

E N

o.:

STA

TE P

RO

JEC

T N

o.:

14- -.

001

609 2

8C

SYM

BOL

REV

ISIO

ND

ATE

SYM

BOL

REV

ISIO

ND

ATE

A B

A B

De partm

e nt of Environmental Protec tion

Division of Re creation and Parks

Bure au of Design and Construc tion

3450 Thomasvill e Rd., Tallahasse e, FL 32309 (850) 488-5372

SHEET NO.

I SS U

E D F

OR

RE V

I EW

RO

OF

P LA N

& D

ETAI

L S

S103

11-1

4-20

14

1/2" = 1'-0"1 ROOF FRAMING PLAN

6 SIMPSON CBSQ POST ANCHOR

4 SIMPSON CBSQ POST CAP3 SIMPSON H14 HC

1 1/2" = 1'-0"2 03 END COLUMN SECTION 1 1/2" = 1'-0"5 BEAM TO WALL DETAIL 1 1/2" = 1'-0"7 SHEATHING NAILING SCHEDULE

1 1/2" = 1'-0"8 SIMPSON LGT GIRDER ANCHOR

1 1/2" = 1'-0"9 SIMPSON MGT GIRDER ANCHOR

PLU

MB

ING

SP

EC

IFIC

ATI

ON

S

ISS

UE

D F

OR

RE

VIE

W

Oke

echo

bee

Bat

tlefie

ld H

isto

ric S

tate

Par

k

DA

Y U

SE

RE

STR

OO

MO

KE

EC

HO

BE

E, F

LOR

IDA

WA

TER

AN

D S

EW

ER

RIS

ER

DIA

GR

AM

S

ISS

UE

D F

OR

RE

VIE

W

Oke

echo

bee

Bat

tlefie

ld H

isto

ric S

tate

Par

k

DA

Y U

SE

RE

STR

OO

MO

KE

EC

HO

BE

E, F

LOR

IDA

FIX

TUR

E S

CH

ED

ULE

AN

D D

ETA

ILS

ISS

UE

D F

OR

RE

VIE

W

Oke

echo

bee

Bat

tlefie

ld H

isto

ric S

tate

Par

k

DA

Y U

SE

RE

STR

OO

MO

KE

EC

HO

BE

E, F