1 2 3 4 5 6 8 9 10 11 12 13 14 1) - JET DARK THINSET Z - SHAPE SLATE STONEPANEL CLADDING PANELS 600 X 200MM (BBA 10/4724) FIXED VIA STONEPANEL SKY HOOKS INTO BLOCKWORK 2) - 100MM TARMAC MEDIUM DENSITY BLOCKWORK WALLBLOCKWORK IS FIXED BACK TO TO PARAPET POST ABOVE ROOF LEVEL AND MAIN STEEL FRAME BELOW ROOF LEVEL 3+6) - 12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF 50MM (BBA 10/4725) 4) - 150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDS U VALUE= 0.18 W/M 2 K 5) - KNAUF VERICAL SFS STUD AT 400MM CENTRES (2MM GAUGE) 7 7) - 25MM(2X12.5MM) (60 MINUTES FIRE PROTECTION) KNAUF ACOUSTIC PLASTERBOARD 600MM STAGGERED FINISH 8) - ROCKWOOL TCB HORIZONTAL CAVITY BARRIER AT EACH FLOOR LEVEL AROUND THE FLOOR PERIMITER TOP FLANGE TO BE FIXED INTO INNER LEAF WITH NAILS (VERTICAL RUN EVERY 10M ALONG PERIMETER) 9) - HOT ROLLED STEEL BEAM 305X165X40MM COATED IN NULLIFIRE SC802 INTUMESCENT PAINT (60 MINUTES FIRE RESISTANCE) 10) - ENGINEERED OAK WOOD FLOOR FINISH 5MM 11) - 80MM FLOATING SAND CEMENT SCREED WITH WET UNDERFLOOR HEATING SYSTEM 12) - 50MM KINGSPAN KOOLTHERM K103 FLOOR BOARD INSULATION (SEPERATING MEMBRANE EITHER SIDE) 13+14) - 200MM CONCRETE CAST IN - SITU FLOOR SLAB REINFORCED TO STRUCTURAL ENGINEERS DESIGN WITH COMFLOOR 51+ STRUCTURAL DECK 15) - RIGITONE ACOUSTIC CEILING BOARD AND SUSPENDED CEILING (ACOUSTIC PERFORMANCE UP TO CLASS B SPREAD OF FIRE RATING: CLASS 0 / EUROCLASS A2) 15 Date Drawing Project A3 Print Date: Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications. All works on this drawing must be carried out by a competent contractor, working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware. Drawing Number Scale @ A3 BSc (Hons) Architectural Design & Technology Cardiff School of Art and Design | Llandaff Campus Student Name, Number & Year 09/05/2021 23:05:56 1 : 5 Cardiff Bay Performing Arts Centre Slate Wall/ Floor Detail 3D 05/05/21 19 Lewis Crisp, st20139299, Year 3 1 : 5 3D DETAIL 1

C:UsersLewisDocumentsYear 3 FINAL YEARPerforming Arts

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

1

2

3

4

5

6

89

10

1112

13

14

1)-JET DARK THINSET Z-SHAPE SLATE STONEPANEL CLADDING PANELS 600 X 200MM (BBA 10/4724)FIXED VIA STONEPANEL SKY HOOKS INTO BLOCKWORK

2)-100MM TARMAC MEDIUM DENSITY BLOCKWORK WALLBLOCKWORK IS FIXED BACK TO TO PARAPET POST ABOVE ROOF LEVEL AND MAIN STEEL FRAME BELOW ROOF LEVEL

3+6)-12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF 50MM (BBA 10/4725)

4)-150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDS U VALUE= 0.18 W/M2K

5)-KNAUF VERICAL SFS STUD AT 400MMCENTRES (2MM GAUGE)

7

7)-25MM(2X12.5MM) (60 MINUTES FIRE PROTECTION)KNAUF ACOUSTIC PLASTERBOARD 600MMSTAGGERED FINISH

8)-ROCKWOOL TCB HORIZONTAL CAVITY BARRIER AT EACH FLOOR LEVEL AROUND THE FLOOR PERIMITERTOP FLANGE TO BE FIXED INTO INNER LEAF WITH NAILS (VERTICAL RUN EVERY 10M ALONG PERIMETER)

9)-HOT ROLLED STEEL BEAM 305X165X40MM COATED IN NULLIFIRE SC802 INTUMESCENTPAINT (60 MINUTES FIRE RESISTANCE)

10)-ENGINEERED OAK WOOD FLOOR FINISH 5MM

11)-80MM FLOATING SAND CEMENT SCREED WITH WET UNDERFLOOR HEATING SYSTEM

12)-50MM KINGSPAN KOOLTHERM K103 FLOOR BOARD INSULATION (SEPERATING MEMBRANE EITHER SIDE)

13+14)-200MM CONCRETE CAST IN-SITU FLOOR SLAB REINFORCED TO STRUCTURAL ENGINEERS DESIGNWITH COMFLOOR 51+ STRUCTURAL DECK

15)-RIGITONE ACOUSTIC CEILING BOARD AND SUSPENDED CEILING (ACOUSTIC PERFORMANCE UP TO CLASS B SPREAD OF FIRE RATING:CLASS 0 / EUROCLASS A2)

15

Date

Drawing

Project

A3P

rint D

ate:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor, working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A3

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:05

:56

1 : 5

Cardiff Bay Performing Arts Centre

Slate Wall/ Floor Detail 3D

05/05/21

19

Lewis Crisp, st20139299, Year 3

1 : 5

3D DETAIL1

E

Parapet

19500.0

JET DARK THINSET Z-SHAPE SLATE STONEPANEL CLADDING PANELS 600 X 200MM (BBA 10/4724)FIXED VIA STONEPANEL SKY HOOKS INTO BLOCKWORK

100MM TARMAC MEDIUM DENSITY BLOCKWORK WALLBLOCKWORK IS FIXED BACK TO TO PARAPET POST ABOVE ROOF LEVEL AND MAIN STEEL FRAME BELOW ROOF LEVEL

100MM AIR GAP

BAUDER PVC HEAT WELDED SINGLE PLY MEMBRANE

150MM JABLITE EPS (EXPANDED POLYSTYRENE)INSULATION BOARD

80MM EPS (EXPANDED POLYSTYRENE)INSULATION BOARD ANGULAR CUT LAID ON FLAT TO CREATE FALLS

12MM WBP PLYWOOD

ALUMASC SKYLINE 3M LENGTH PARAPET COPINGANTHRACITE GREY 50.0 100.0 100.0 12.0 150.0 12.0 150.0

2. 0

50.0

200.0

100MM ANCON PARAPET POST IN BETWEEN SFS PANELS FIXED TO THE TOP OF CONCRETE ROOF SLAB

KNAUF SFS STUD AT 400MMCENTRES (2MM GAUGE)

Roof

18000.0

150.0

STONEPANEL SKY HOOK FIXINGSFOR SLATE CLADDING PANELS

VISQUEEN VAPOUR BARRIER 2MM GAUGE

12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF 50MM (BBA 10/4725)

HOT ROLLED STEEL COLUMN 254X254X73MM COATED IN NULLIFIRE SC802 INTUMESCENTPAINT (60 MINUTES FIRE RESISTANCE)

HOT ROLLED STEEL BEAM 305X165X40MM COATED IN NULLIFIRE SC802 INTUMESCENTPAINT (60 MINUTES FIRE RESISTANCE)

COMFLOR 51+ STEEL STRUCTURAL DECK

200MM CAST IN-SITU CONCRETETRUE FLAT ROOF SLAB REINFORCED TO STRUCTURAL ENGINEERS DESIGN

KINGSPAN NILVENT BREATHER FELT VAPOUR CONTROL LAYER 0.6MM GAUGE

150MM ENERTHERM PIR INSULATION U-VALUE= 0.16W/M2K

20MM TWO-COAT IKO PERMAPHALT SHEET (BBA 03/4009)

20MM THREE-COAT IKO PERMAPHALT SHEET ON UPSTAND 150MM ABOVE FINISH FLOOR LEVEL (BBA 03/4009)

18460.0

ROCKWOOL TCB HORIZONTAL CAVITY BARRIER AT EACH FLOOR LEVEL AROUND THE FLOOR PERIMITER TOP FLANGE TO BE FIXED INTO INNER LEAF WITH NAILS (VERTICAL RUN EVERY 10M ALONG PERIMETER)

25MM DRAINAGE LAYER

25MM GROWING MEDIUM

40MM SEDUM FINISH

GRAVEL INFILL AROUND THE GUTTER WITH METAL GRATE SURROUND

100MM GUTTER DOWNPIPE RUNNING INBETWEEN COLUMNS

ACO RAINWATER ROOF OUTLET VERTICAL SPIGOT WITH DOME GRATE SPACED EVERY 1200MM WITH 0% FALLS100MM PIPE INSERT

12.5MM GYPSUM ACOUSTIC PLASTERBOARD CEILING

40.0

25.0

25.0

20.0

150.0

200.0

322.5

12.5

50.0 100.0 100.0 12.0 150.0 12.512.5

12.5

150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDS U VALUE= 0.18 W/M2K

25MM(2X12.5MM) (60 MINUTES FIRE PROTECTION) KNAUF ACOUSTIC PLASTERBOARD 600MM STAGGERED FINISH

Knauf 28mm ceiling batten/rail

Date

Drawing

Project

A2P

rint D

ate:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor, working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A2

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:05

:58

1 : 5

Cardiff Bay Performing Arts Centre

Parapet Wall/ Green Roof Detail

03/26/21

20

Lewis Crisp, st20139299, Year 3

1 : 5

Parapet/Roof Detail2A

Level 1

0.0

E

HOT ROLLED STEEL COLUMN 254X254X73MM COATED IN NULLIFIRE SC802 INTUMESCENTPAINT (60 MINUTES FIRE RESISTANCE)

150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDSU VALUE= 0.18 W/M2K

JET DARK THINSET Z-SHAPE SLATE STONEPANEL CLADDING PANELS 600 X 200MM (BBA 10/4724)FIXED VIA STONEPANEL SKY HOOKS INTO BLOCKWORK

100MM TARMAC MEDIUM DENSITY BLOCKWORK WALL FOR ANCHORING SUPPORT

100MM AIR GAP

VISQUEEN VAPOUR BARRIER 2MM GAUGE

VISQUEEN ZEDEX TRAY DPC 0.6MM

IBSTOCK LODGE LANE BLUE SOLID65X102.5X215MM BRICK PLINTH WALL

100MM TARMAC MEDIUM DENSITY BLOCKS ON FLAT

3MM PROTECTION BOARD (BITUMEN IMPREGNATED FIBRE BOARD)

1.6MM SHEETSEAL 226 SELF ADHESIVE TANKING MEMBRANE(BBA 20/5805)

SHEETSEAL 226 PRIMER

HOT ROLLED STEEL BEAM 305X165X40MM COATED IN NULLIFIRE SC802 INTUMESCENTPAINT (60 MINUTES FIRE RESISTANCE)

COMFLOR 51+ STRUCTURAL DECK

200MM CONCRETE C20 CAST IN-SITU FLOOR SLAB REINFORCED TO STRUCTURAL ENGINEERS DESIGN

100MM KINGSPAN KOOLTHERM K103 FLOOR BOARD INSULATION U VALUE=0.13W/M2K 0.3 P/A

80MM FLOATING SAND CEMENT SCREED WITH WET UNDERFLOOR HEATING SYSTEM

ENGINEERED OAK WOODFLOOR FINISH 5MM

KNAUF SFS STUD AT 400MMCENTRES (2MM GAUGE)

ROCKWOOL MINERAL WOOL PACKED INSULATION

50.0 100.0 100.012.0

50.0

12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF 50MM(BBA 10/4725)

25MM(2X12.5MM) (60 MINUTES FIRE PROTECTION) KNAUF ACOUSTIC PLASTERBOARD600MM STAGGERED FINISH

5.0

80.0

100.0

200.0

CONCRETE FILLET

350MM PRECAST CONCRETE RETAINING WALL (L-SHAPED) TO STRUCTURAL ENGINEERS DESIGN

6.6 350.0 60.5 247.8

100.0 12.512.5

112.8 10.012.5

SEPARATING LAYER

STONEPANEL SKY HOOK FIXINGS

10.0

40.0

200.0

200.0

124.1

39.1

100.0

10.0

109.7

5.0

18MMX143MM SQUARE EDGE MDF SKIRTING BOARD

Date

Drawing

Project

A2P

rint D

ate:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of

the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor,

working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A2

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:05

:59

1 : 5

Cardiff Bay Performing Arts Centre

Retaining Wall/ Level 1 Floor Detail

03/26/21

21

Lewis Crisp, st20139299, Year 3

1 : 5

Retaining Wall detail3

Level 2

3600.0

VB150S-6.5 CLADDING HELPING HAND BRACKET FOR VERTICAL ORIENTATED PANELS FIXED TO VERTICAL SECTIONS

GARAPA KD VERTICAL PRE-TREATED TIMBER CLADDING 18 X 90

HORIZONTAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

VERTICAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

50MM VENTILATED VOID

ENGINEERED OAK WOOD FLOOR FINISH 5MM

80MM FLOATING SAND CEMENT SCREED WITH WET UNDERFLOORHEATING SYSTEM

SEPARATING LAYER

50MM KINGSPAN KOOLTHERM K103 FLOOR BOARD INSULATION

200MM CONCRETE C20 CAST IN-SITU FLOOR SLAB REINFORCED TO STRUCTURAL ENGINEERS DESIGN

COMFLOR 51+ STRUCTURAL DECK

HOT ROLLED STEEL BEAM 305X165X40MM COATED IN NULLIFIRE SC802 INTUMESCENT(60 MINUTES FIRE RESISTANCE) PAINT

KNAUF SFS C STUD AT 400MMCENTRES (2MM GAUGE)

150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDS U VALUE= 0.18 W/M2K

12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF 50MM BBA:10/4725

25MM(2X12.5MM)KNAUF ACOUSTIC PLASTERBOARD600MM STAGGERED FINISH(60 MINUTES FIRE PROTECTION)

RIGITONE ACOUSTIC CEILING BOARD (ACOUSTIC PERFORMANCEUP TO CLASS B SPREAD OF FIRE RATING: CLASS 0 / EUROCLASS A2)

5.0

85.0

50.0

200.0

305.9

45.0

12.0

18MMX143MM SQUARE EDGE MDF SKIRTING BOARD

3600.0

VISQUEEN VAPOUR BARRIER 2MM GAUGE

KNAUF SFS VERTICAL SECTIONS AT 400MM CENTRES FOR SINIAT WEATHER DEFENCE FIXING BEHIND VERTICAL BATTERNS

12.0

50.050.0

18.0 138.0 12.0 150.0 12.5

12.5

12.5

ROCKWOOL TCB HORIZONTAL CAVITY BARRIER AT EACH FLOOR LEVEL AROUND THE FLOOR PERIMITERTOP FLANGE TO BE FIXED WITH NAILS INTO THE INNER LEAF (VERTICAL RUN EVERY 10M ALONG PERIMETER)

Date

Drawing

Project

A3

Prin

t Dat

e:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of

the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor,

working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A3

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:06

:00

1 : 5

Cardiff Bay Performing Arts Centre

Timber Rainscreen Wall/Intermediate Floor Detail

03/26/21

22

Lewis Crisp, st20139299, Year 3

1 : 5

Rainscreen Wall/Floor Detail1

12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF 50MM BBA:10/4725

150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDS U VALUE= 0.18 W/M2K

VISQUEEN VAPOUR BARRIER 2MM GAUGE

GARAPA KD VERTICAL TIMBER CLADDING 19 X 90

HORIZONTAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

VB150S-6.5 CLADDING HELPING HAND BRACKET FOR VERTICAL ORIENTATED PANELS

SKYLINE ALUMINIUM CILL X 3 METRE LENGTH WITH 3 BENDS ANTHRACITE GREY RAL 7016

150MM KINGSPAN KOOLTHERM CAVITY CLOSER

150MM MOISTURE RESISITANT MDF WINDOW BOARDWHITE FINISH WITH BULLNOSE PROFILE

2000x2400MM INTERNORM KF520 ALUMINIUM/ UPVC WINDOW FRAME (ANTHRACITE GREY) WITH TRIPLE GLAZING 4MM PANES WITH 18MM ARGON FILLED INBETEEN PANES U VALUE= 0.7W/M2K

EXPANDING FOAM SPRAYED BELOW CILL TO PREVENT THERMAL BRIDGING

18.0

50.0

50.0150.012.0150.0

12.5

EXTERNAL INTERNAL

KNAUF SFS STUD AT 400MMCENTRES (2MM GAUGE)

PROPOSED LOCATION OF WINDOW FIXING TO STEEL SFS STUD

VERTICAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

50MM VENTILATED VOID

12.5

12.5

BEAD OF SEALANTSOUDAL SILIRUB LMN SILICONEANTHRACITE GREY

BEAD OF SEALANTSOUDAL SILIRUB LMN SILICONEANTHRACITE GREY

KNAUF SFS VERTICAL SECTIONS AT 400MM CENTRES FOR SINIAT WEATHER DEFENCE FIXING BEHIND VERTICAL BATTERNS

200.0

25MM(2X12.5MM) (60 MINUTES FIRE PROTECTION) KNAUF ACOUSTIC PLASTERBOARD 600MM STAGGERED FINISH

Date

Drawing

Project

A3

Prin

t Dat

e:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of

the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor,

working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A3

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:06

:01

1 : 5

Cardiff Bay Performing Arts Centre

General Window Cill Detail

03/29/21

23

Lewis Crisp, st20139299, Year 31 : 5

Window Cill Detail1

2000x2400MM INTERNORM KF520 ALUMINIUM/ UPVC WINDOW FRAME (ANTHRACITE GREY) WITH TRIPLE GLAZING 4MM PANES WITH 18MM ARGON FILLED INBETEEN PANES U VALUE= 0.7W/M2K

GARAPA KD VERTICAL TIMBER CLADDING 19 X 90

HORIZONTAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

VB150S-6.5 CLADDING HELPING HAND BRACKET FOR VERTICAL ORIENTATED PANELS

150MM KINGSPAN KOOLTHERM CAVITY CLOSER

VERTICAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

50MM VENTILATED VOID

KNAUF SFS VERTICAL SECTIONS AT 400MM CENTRES FOR SINIAT WEATHER DEFENCE FIXING BEHIND VERTICAL BATTERNS

12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF 50MM BBA:10/4725

150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDS U VALUE= 0.18 W/M2K

VISQUEEN VAPOUR BARRIER 2MM GAUGE

KNAUF SFS STUD AT 400MMCENTRES (2MM GAUGE)

25MM(2X12.5MM) (60 MINUTES FIRE PROTECTION) KNAUF ACOUSTIC PLASTERBOARD 600MM STAGGERED FINISH

BEAD OF SEALANTSOUDAL SILIRUB LMN SILICONEANTHRACITE GREY

EXTERNAL INTERNAL

Date

Drawing

Project

A3

Prin

t Dat

e:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of

the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor,

working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A3

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:06

:01

1 : 5

Cardiff Bay Performing Arts Centre

General Window Head Detail

05/05/21

24

Lewis Crisp, st20139299, Year 3

1 : 5

Window Head Detail1

E

Level 5

14400.0

KNAUF SFS VERTICAL SECTIONS AT 400MM CENTRES FOR SINIAT WEATHER DEFENCE FIXING BEHIND VERTICAL BATTERNS

VB150S-6.5 CLADDING HELPING HAND BRACKET FOR VERTICAL ORIENTATED PANELS

GARAPA KD VERTICAL TIMBER CLADDING 19 X 90

HORIZONTAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

VERTICAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

VISQUEEN VAPOUR BARRIER 2MM GAUGE

50MM VENTILATED VOID

12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF 50MM BBA:10/4725

14405.0

150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDS U VALUE= 0.18 W/M2K

KNAUF SFS STUD AT 400MM CENTRES (2MM GAUGE)

ENGINEERED OAK WOOD FLOOR FINISH 5MM

80MM FLOATING SAND CEMENT SCREED WITH WET UNDERFLOORHEATING SYSTEM

SEPARATING LAYER

50MM KINGSPAN KOOLTHERM K103 FLOOR BOARD INSULATION

200MM CONCRETE CAST IN-SITU FLOOR SLAB REINFORCED TO STRUCTURAL ENGINEERS DESIGN

COMFLOR 51+ STRUCTURAL DECK

HOT ROLLED STEEL BEAM 305X165X40MM COATED IN NULLIFIRE SC802 INTUMESCENT(60 MINUTES FIRE RESISTANCE) PAINT

GYPROC FIRELINE (2 x 15MM) PLASTERBOARD CEILING

ALUK SL52 DOUBLE GLAZED CURTAIN WALL SYSTEM (SLANTED)1.297 W/m²K - 1.334 W/m²K

HORIZONTAL TRANSOM POLYESTER POWDER COATED RAL 7016 ANTHRACITE GREY

VERTICAL MULLION POLYESTER POWDER COATED RAL 7016 ANTHRACITE GREY

HOT ROLLED STEEL COLUMN(SLANTED) 305X165X40MM COATED IN NULLIFIRE SC802 INTUMESCENT(60 MINUTES FIRE RESISTANCE) PAINT

MIRROR GLAZING PANEL TO HIDE MAIN STEEL FRAME BEHIND

ROCKWOOL TCB HORIZONTAL CAVITY BARRIER AT EACH FLOOR LEVEL AROUND THE FLOOR PERIMITER TOP FLANGE TO BE FIXED WITH NAILS INTO INNER LEAF (VERTICAL RUN EVERY 10M ALONG PERIMETER)

ROCKWOOL FLEXI INSULATION SLAB 50MM

ALUMINIUM POLYESTER POWDER COATED FLASHING FIXED INTO SFS SINIAT WEATHER DEFENCE BOARD

STEEL ANGULAR CURTAIN WALL FIXING

ANGULAR CURTAIN WALL FIXING TO MAIN STEEL FRAME

SHADOW GAP

18.0 50.0 50.0 12.0 138.0 12.0 150.0 12.5

5.0

85.0

50.0

200.0

Date

Drawing

Project

A2P

rint D

ate:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of

the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor,

working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A2

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:06

:02

1 : 5

Cardiff Bay Performing Arts Centre

Curtain Wall Head Detail

04/03/21

25

Lewis Crisp, st20139299, Year 3

1 : 5

Curtain Wall Head1

Level 1

0.0

D

ALUK SL52 DOUBLE GLAZED CURTAIN WALL SYSTEM (SLANTED TO ALUK REQUIREMENTS)1.297 W/m²K - 1.334 W/m²K

VERTICAL MULLION POLYESTER POWDER COATED RAL 7016 ANTHRACITE GREY

ENGINEERED OAK WOOD FLOOR FINISH 5MM

80MM FLOATING SAND CEMENT SCREED WITH WET UNDERFLOORHEATING SYSTEM

SEPARATING LAYER

100MM KINGSPAN KOOLTHERM K103 FLOOR BOARD INSULATION

200MM CONCRETE CAST IN-SITU FLOOR SLAB REINFORCED TO STRUCTURAL ENGINEERS DESIGN

COMFLOR 51+ STRUCTURAL DECK

5.0

80.0

100.0

200.0

5.0

HORIZONTAL TRANSOM POLYESTER POWDER COATED RAL 7016 ANTHRACITE GREY

COVER PLATE FOR STEEL GOING THROUGH FLOOR LEVEL

SLANTED HOT ROLLED STEEL COLUMN 254X254X73MM FIXED AT BASE TO MAIN STEEL STRUCTURE COATED IN NULLIFIRE SC802 INTUMESCENT PAINT (60 MINUTES FIRE RESISTANCE)

ALUMINIUM CILL PPC RAL 7016 FOR SL52 CURTAIN WALL SYSTEM

IBSTOCK LODGE LANE BLUE SOLID65X102.5X215MM BRICK PLINTH WALL

3MM PROTECTION BOARD (BITUMEN IMPREGNATED FIBRE BOARD)

1.6MM SHEETSEAL 226 SELF ADHESIVE TANKING MEMBRANE (BBA 20/5805)

SHEETSEAL 226 PRIMER

350MM PRECAST CONCRETE RETAINING WALL (L-SHAPED) TO STRUCTURAL ENGINEERS DESIGN

HOT ROLLED STEEL BEAM 305X165X40MM OFFSET 70MM COATED IN NULLIFIRE SC802 INTUMESCENTPAINT (60 MINUTES FIRE RESISTANCE)

CURTAIN WALL STEEL FIXING PLATE INTO CAST IN SITU FLOOR SLAB

70.0

Date

Drawing

Project

A3P

rint D

ate:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor, working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A3

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:06

:02

1 : 5

Cardiff Bay Performing Arts Centre

Curtain Wall Base Detail

04/02/21

26

Lewis Crisp, st20139299, Year 3

1 : 5

Curtain Wall Base1

12

A

JET DARK THINSET Z-SHAPE SLATE STONEPANEL CLADDING PANELS 600 X 200MM (BBA 10/4724)FIXED VIA STONEPANEL SKY HOOKS INTO BLOCKWORK

100MM TARMAC MEDIUM DENSITY BLOCKWORK WALL FOR ANCHORING SUPPORT

100MM AIR GAPVISQUEEN VAPOUR BARRIER 2MM GAUGE

KNAUF SFS C STUD AT 400MMCENTRES (2MM GAUGE)

150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDS U VALUE= 0.18 W/M2K

12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF50MM BBA:10/4725

300.0 300.0

25.0 100.0 25.0

50.0

100.0

100.0

12.0

150.0

METSEC 100MM STUD & TRACK PARTITION SYSTEM(PRE-GALVANISED MILD STEEL)

100MM KNAUF ACOUSTIC INSULATION

25MM(2X12.5MM)KNAUF ACOUSTIC PLASTERBOARD600MM STAGGERED FINISH(60 MINUTES FIRE PROTECTION)

25MM(2X12.5MM)KNAUF ACOUSTIC PLASTERBOARD600MM STAGGERED FINISH(60 MINUTES FIRE PROTECTION)

12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF50MM BBA:10/4725

25.0

12.0

Date

Drawing

Project

A3P

rint D

ate:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor, working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A3

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:06

:03

1 : 5

Cardiff Bay Performing Arts Centre

METSEC Partition Detail 1

04/08/21

27

Lewis Crisp, st20139299, Year 3

1 : 5

METSEC Partition Detail 11

7

A

METSEC COLUMN ENCASEMENT FIXINGS

METSEC 100MM STUD & TRACK PARTITION SYSTEM (PRE-GALVANISED MILD STEEL)

100MM KNAUF ACOUSTIC INSULATION

25MM(2X12.5MM)KNAUF ACOUSTIC PLASTERBOARD600MM STAGGERED FINISH(60 MINUTES FIRE PROTECTION)

VISQUEEN VAPOUR BARRIER 2MM GAUGE

KNAUF SFS C STUD AT 400MMCENTRES (2MM GAUGE)

150MM GYPROC THERMALINE RIGID INSULATION INBETWEEN STUDS U VALUE 0.18 W/M2K

18.0

50.0

50.0

150.0

12.0

150.0

12.0

25.0 100.0 25.0

ROCK MINERAL WOOL - KNAUF INSULATION ROCKSILK® RS45

25.0

25MM(2X12.5MM)KNAUF ACOUSTIC PLASTERBOARD600MM STAGGERED FINISH(60 MINUTES FIRE PROTECTION)

12.0MM SINIAT WEATHER DEFENSE BOARD OVERLAPPED AND TAPED BY A MINIUMUM OF 50MM BBA:10/4725

KNAUF SFS VERTICAL SECTIONS AT 400MM CENTRES FOR SINIAT WEATHER DEFENCE FIXING BEHIND VERTICAL BATTERNS

GARAPA KD VERTICAL TIMBER CLADDING 18 X 90

HORIZONTAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

VERTICAL 38X50MM TREATED TIMBER BATTENS AT 600MM CENTRES

50MM VENTILATED VOID

Date

Drawing

Project

A3P

rint D

ate:

Do not scale from this drawing. If ambiguities are found or additional dimensions required, these must be brought to the attention/ requested of the drawing originator. This drawing is to be read in conjunction with the all relevant project information including general arrangement drawings, specifications.

All works on this drawing must be carried out by a competent contractor, working to a risk assessment and method statement. Designers risk assessment should also be consulted for the identification of any design risks the client or contractor may not otherwise be aware.

Drawing Number

Scale @ A3

BSc (Hons) Architectural Design & Technology

Cardiff School of Art and Design | Llandaff Campus

Student Name, Number & Year

09/0

5/20

21 2

3:06

:03

1 : 5

Cardiff Bay Performing Arts Centre

METSEC Partition Detail 2

04/09/21

28

Lewis Crisp, st20139299, Year 3

1 : 5

METSEC Partition Detail 21