57
www.nafsa.es
Sim
ple
effe
ct li
near
sol
enoi
ds CU30/C TYPE
Force-stroke curve
Solenoid protection rate: IP40Insulation class: E (120ºC)Cycle duration: 4 minutesStandard stroke "s": 10 mmTemperature rise: "DV31 " 70ºCWork: pull/pushIncorporated return spring: YES
Ordering code: CU30/C --V ED---%Example:Standard voltage:24Vdc Duty-cycle: ED100%: With spring :CU30/C 24Vdc ED100% RSStandard voltage:12Vdc Duty-cycles: ED15%: Without spring :CU30/C 48Vdc ED15% RN
1)Under demand voltage:They can be manufactured at any voltagebetween the maximum and the minimumvoltage values shown in the chart.2)To feed in alterning current the soleoindwill have an internal rectifier.*It is possible to feed at 230V 50Hz withexternal rectifier.3)The duty-cycles described in the chart arestandard, they can be manufactured in anyintermediate cycle.4)If any variation from the original is needed,please ask us.5)Earthing is recommended if the metallicparts are accessible.
Calculation of the effective force: see pages 1 and 52
Duty-cycle ED(%) 100 40 25 15 5Abs. Power at 20ºC (W) 7.2 18 30 53 150Minimum force (N) 2.6 3.8 7.3 9.9 17.2
Max time under voltage(s) h 96 60 36 12Plunger weight (g) 40Plunger weight (g) 290
Duty-cycle Standard voltages Under demand voltages ED% VDC VAC VDC VAC
Solenoid under voltage
6 12 24 48 100 125 205 110 230 Min Max Min Max 100% o o o o o o o o x 3 250 24 125 40% o o o o o o o o x 4 250 48 125
25% o o o o o o o o x 5 250 110 125 15% o o o o o o o x x 6 250 x x 5% x o o o o o o x x 12 250 x x
Lay out: o = Available ; x = Unavailable