53
CT SPECIAL APPLICATIONS

CT SPECIAL APPLICATIONS. CT ANGIOGRAPHY CT IMAGE OF THE BLOOD VESSEL OPACIFIED BY CONTRAST

Embed Size (px)

Citation preview

CT SPECIAL APPLICATIONS

CT ANGIOGRAPHY

CT IMAGE OF THE BLOOD VESSEL OPACIFIED BY

CONTRAST

REQUIREMENTS FOR CTA

• PATIENT PREPARATION

• ACQUSITION PARAMETERS

• CONTRAST MEDIUM ADMINISTRATION

• POSTPROCESSING TECHNIQUES

PATIENT PREP.

• BUN 7-20 mg/dl

• CREAT.- 0.6 –1.2 mg/dl

• IODINE ALLERGY- STEROID THERAPY

• HYPERVENTILATION BEFORE EXAM FOR BETTER BREATHOLD

CONTRAST ADMINISTERED WITH POWER INJECTOR

POWER INJECTOR PARAMETERS

VOLUME OF CONTRAST-ml

RATE ml/sec

TIME OF INJECTION – sec

SCAN DELAY TIME - sec

CARE BOLUS

                                                                                            

ACQUSITION PARAMETERS

PE?

Circle of Willis

Circle of Willis?!

40 SEC

ABDOMINAL CTA

CTA - MPR

PLANE?

ABDOMINAL AND FEMORAL RUNOFF

CARDIAC CT

CARDIAC CT PROCEDURES

• CARDIAC ANGIOGRAM

• CALCIUM SCORING

CALCIUM SCORING

NO IV CONTRAST USED

CALCIUM SCORING

CARDIAC ANGIOGRAMPERFORMED WITH CONTRAST

INJECTION

4-5 cc/sec

150 cc total volume

CARDIAC ANGIOGRAM

CINE CTA

VIRTUAL ENDOSCOPY

• USE OF VIRTUAL REALITY CONCEPTS TO THE CREATION OF INNER VIEWS OF TUBULAR STRUCTURES

VIRTUAL ENDOSCOPE

GRAPHICS-BASED SOFTWARE USED FOR SIMULATING ENDOSCOPIC EXPLORATION

INSIDE A 3-D IMAGE

APPLICATION OF VIRTUAL ENDOSCOPY

• COLONOSCOPY

• BRONCHOSCOPY

• CHOLANGIOPANCREATOSCOPY

• SINUS ENDOSCOPY

• BLADDER

• SPINAL CANAL ENDOSCOPY

• VESSEL ENDOSCOPY- ANGIOSCOPY

• NEURONS

• UTERUS & FALLOPIAN TUBES

COLONOSCOPY

BRONCHOSCOPY

                                                 

                  

VENTRICULOSCOPY

CORONARY ENDOSCOPY

DISADVANTAGE OF VIRTUAL ENDOSCOPY

• HIGH COST• LACK OF QUANTITATIVE DATA• INABILITY OF PERFORMANCE OF

REAL INTERVENTIONAL PROCEDURE WITHOUT REAL ENDOSCOPE

• NO INFO ON MUCOSAL SURFACE• IMAGE QUALITY LIMITED BY

RESOLUTION OF SYSTEM.

CT FLUORO

CONVENTIONAL CT LIMITATION

• LACK OF REAL TIME IMAGE DISPLAY

DATA COLLECTION IMAGE RECON

LAG!!

FUNDAMENTAL PRINCIPLES OF REAL TIME IMAGING

• FAST CONTINUOUS SCANNING

• FAST IMAGE RECONSTRUCTION

• CONTINUOUS IMAGE DISPLAY

RADIATION TREATMENT

The 65 cm variable field of viewdelivers 15 additional cm of visualcoverage, allowing clinicians tosee a patient’s entire anatomy,facilitating precise radiation therapyplanning

Quantitative CT

• MEASUREMENT OF MINERAL CONTENT OF TRABECULAR BONE IN OSTEOPOROSIS

BMD

QUANTITATIVE CT - STEPS

SCOUT SLICE SELECTION AXIALIMAGES

AUTOMATIC CANTOUR TRACING

ROI

MEAN VALUE CALCULATIONROI VALUE

CONVERTED TO

BMD VALUE

GRAPHIC OUTPUT, GRAPH BMD vs AGE, COMPARISON PERFORMED

XENON CT

• INHALATION OF XENON GAS.

XENON CT

Z # 54

XENON- IDEAL GAS FOR STUDYING BRAIN FUNCTION AND CEREBRAL

BLOOD FLOW • HIGH Z# - HIGH ATTENUATION

• HIGH FAT SOLUBILITY

• ABILITY TO CROSS BLOOD BRAIN BARRIER

XENON CT

• USEFUL IN EVALUATING REGIONAL PERFUSION IN CEREBROVASCULAR DISEASE AND STUDYING BRAIN METABOLISM.

• CLINICAL ROLE IN STUDYING:

DEMENTIA, SLEEP DISORDERS, MIGRANES, AND EPILEPSY