2
CS40/41 10-BOLT MUNCIE START ® PTO ACTIVATION Allison 3000/4000 Series Transmissions A PTO Special Feature Code: 6 – Muncie Start ® 12V HARNESS CONNECTION HARNESS CONNECTION B TORQUE TO 10-13 FT.LBS. TORQUE TO 3 FT.LBS. (2 PLCS) INSTALL IN TRANSMISSION PRESSURE PORT SEE STEP SOLENOID VALVE ROTATABLE PRESSURE SWITCH TORQUE TO 10-12 FT.LBS. TO TRANSMISSION PORT 2 A B RED BLUE GREEN BLACK BLUE RED BLACK GREEN BATTERY + 10A FUSE Solenoid Valve Pressure Switch TO BATTERY GROUND Port Right Side Port Left Side Port 3 Make connections to A and B from Step 1 * Left Side INDICATOR LIGHT Muncie Start Module Mount in dash Main Pressure Port “P” 7/16-20 UNF 2A (SAE -4) 180-320 PSI Main Pressure Port “P” 7/16-20 UNF 2A (SAE -4) 180-320 PSI Main Pressure Port “P” 7/16-20 UNF 2A (SAE -4) 180-298 PSI Light is to be “ON” when unit is engaged and “OFF” when unit is disengaged, and will not light up until pressure in clutch is at full engagement pressure. Mount the activation switch in clear view of the operator. Indicator light must be installed in clear view of operator while seated in vehicle’s driver seat. Use 36MK1210-A if additional warning light is needed. *Do not install other electrical components or devices to the Muncie pressure switch or Muncie Start module. ** Clutch shift PTO requires connection to Allison “PTO Enable Input” Circuit on Allison Gen. 4 and later controls. Contact Muncie Power or Allison for more details. Check with vehicle dealer or body builder’s information for location. 201 East Jackson Street • Muncie, Indiana 47305 800-367-7867 • Fax 765-284-6991 • [email protected] • www.munciepower.com Specifications are subject to change without notice. Visit www.munciepower.com for warranties and literature. All rights reserved. © Muncie Power Products, Inc. (2020) A Member of the Interpump Group IN20-02 (Rev. 04-20) B PRESSURE SWITCH TO PORT 3 360 HARNESS CONNECTION HARNESS CONNECTION INSTALL IN TRANSMISSION PRESSURE PORT SEE STEP 2 TO TRANSMISSION PRESSURE PORT PTO Shift Codes: SR (12VDC Muncie Start ® ), TR (24VDC Muncie Start ® ) A SOLENOID VALVE ROTATABLE PORT 1 PORT 2 PORT 3 PORT 4 LUBE CLUTCH EXHAUST TORQUE TO 3 FT.LBS. (2 PLCS) TORQUE ALL FITTINGS TO 10-13 FT.LBS. TORQUE TO 10-12 FT.LBS.

CS40/41 10-BOLT MUNCIE START PTO ACTIVATION 3 Allison …...SOLENOID VALVE ROTATABLE PRESSURE SWITCH TORQUE TO 10-12 FT.LBS. TO TRANSMISSION PORT 2 A B RED BLUE GREEN BLACK BLUE BLACK

  • Upload
    others

  • View
    9

  • Download
    2

Embed Size (px)

Citation preview

Page 1: CS40/41 10-BOLT MUNCIE START PTO ACTIVATION 3 Allison …...SOLENOID VALVE ROTATABLE PRESSURE SWITCH TORQUE TO 10-12 FT.LBS. TO TRANSMISSION PORT 2 A B RED BLUE GREEN BLACK BLUE BLACK

CS40/41 10-BOLT MUNCIE START® PTO ACTIVATIONAllison 3000/4000 Series Transmissions

A

PTO Special Feature Code: 6 – Muncie Start® 12V

B

PRESSURESWITCH TO PORT 3

HARNESS CONNECTION

HARNESS CONNECTION

INSTALL IN TRANSMISSION PRESSURE PORTSEE STEP 2

TO TRANSMISSION PRESSURE PORT

A

PORT 1PORT 2PORT 3

PORT 4

HARNESS CONNECTION

HARNESS CONNECTION

TORQUE ALL FITTINGS TO 10-13 FT.LBS.

TORQUE TO10-12 FT.LBS.

BTORQUE TO10-13 FT.LBS.

TORQUE TO 3 FT.LBS. (2 PLCS)

PTO Special Feature Code: 6 – Muncie Start® 12V

360SOLENOIDVALVEROTATABLETORQUE TO3 FT.LBS.(2 PLCS)

EXHAUST

CLUTCH

LUBE

INSTALL INTRANSMISSIONPRESSURE PORT SEE STEP

SOLENOID VALVE ROTATABLE

PRESSURE SWITCH TORQUE TO 10-12 FT.LBS.

TO TRANSMISSIONPORT

2

A B

REDBLUE

GREEN

BLACK

BLUE

REDBLACK

GREEN

BATTERY

+10A

FUSE

Solenoid Valve Pressure Switch

TOBATTERYGROUND

Port

Right Side

Port

Left Side

Port

3Make connections to A and B from Step 1

*

Left Side

INDICATOR LIGHT

Muncie Start Module

Mount in dash

Main Pressure Port “P”7/16-20 UNF 2A (SAE -4)180-320 PSI

Main Pressure Port “P”7/16-20 UNF 2A (SAE -4)180-320 PSI

Main Pressure Port “P”7/16-20 UNF 2A (SAE -4)180-298 PSI

Light is to be “ON” when unit is engaged and “OFF” when unit is disengaged, and will not light up until pressure in clutch is at full engagement pressure. Mount the activation switch in clear view of the operator. Indicator light must be installed in clear view of operator while seated in vehicle’s driver seat. Use 36MK1210-A if additional warning light is needed.

*Do not install other electrical components or devices to the Muncie pressure switch or Muncie Start module.

** Clutch shift PTO requires connection to Allison “PTO Enable Input” Circuit on Allison Gen. 4 and later controls. Contact Muncie Power or Allison for more details. Check with vehicle dealer or body builder’s information for location.

201 East Jackson Street • Muncie, Indiana 47305800-367-7867 • Fax 765-284-6991 • [email protected] • www.munciepower.com

Specifications are subject to change without notice. Visit www.munciepower.com for warranties and literature. All rights reserved. © Muncie Power Products, Inc. (2020)A Member of the Interpump Group

IN20-02 (Rev. 04-20)

BPRESSURE SWITCH TO PORT 3

360

HARNESS CONNECTION

HARNESS CONNECTION

INSTALL IN TRANSMISSION PRESSURE PORTSEE STEP 2

TO TRANSMISSION PRESSURE PORT

PTO Shift Codes: SR (12VDC Muncie Start®), TR (24VDC Muncie Start®)

A

SOLENOID VALVE ROTATABLE

PORT 1PORT 2PORT 3

PORT 4LUBECLUTCH

EXHAUST

TORQUE TO 3 FT.LBS. (2 PLCS)

TORQUE ALL FITTINGS TO 10-13 FT.LBS.

TORQUE TO 10-12 FT.LBS.

Page 2: CS40/41 10-BOLT MUNCIE START PTO ACTIVATION 3 Allison …...SOLENOID VALVE ROTATABLE PRESSURE SWITCH TORQUE TO 10-12 FT.LBS. TO TRANSMISSION PORT 2 A B RED BLUE GREEN BLACK BLUE BLACK

201 East Jackson Street • Muncie, Indiana 47305800-367-7867 • Fax 765-284-6991 • [email protected] • www.munciepower.com

Las especificaciones están sujetas a cambios sin previo aviso. Visite www.munciepower.com para obtener garantías y documentación. Todos los derechos reservados. © Muncie Power Products, Inc. (2020)Miembro de Interpump Group

IN20-02 (Rev. 04-20)

201 East Jackson Street • Muncie, Indiana 47305800-367-7867 • Fax 765-284-6991 • [email protected] • www.munciepower.com

Las especificaciones están sujetas a cambios sin previo aviso. Visite www.munciepower.com para obtener garantías y documentación. Todos los derechos reservados. © Muncie Power Products, Inc. (2017)Miembro de Interpump Group

IN17-09 (Rev. 10-17)

A B

ROJOAZUL

VERDE

NEGRO

AZUL

ROJONEGRO

VERDE

BATERIA

+FUSIBLE

10A

Válvula solenoide Interruptor de presión

A LAMASA DE

LA BATERÍAPuerto

Lado derecho

Puerto

Lado izquierdo

Puerto

3Haga conexiones aA y B desde el Paso 1

*

Lado izquierdo

LUZ INDICADORA

Módulo Muncie Start

Montaje en el tablero

Puerto de presión principal “P”7/16-20 UNF 2A (SAE -4)180-320 PSI

Puerto de presión principal “P”7/16-20 UNF 2A (SAE -4)180-320 PSI

Puerto de presión principal “P”7/16-20 UNF 2A (SAE -4)180-298 PSI

Ubicaciones delpuerto de presiónde transmisión

Instalación del arnés de cableado

SERIE 3000

SERIE 4000 A LA CONEXIÓN TCM (MÓDULO DECONTROL DE TRANSMISIÓN)

DE ALLISON PARA LA ENTRADADE ACTIVACIÓN DE LA TDF**

La luz debe estar en “ON” (ENCENDIDA) cuando la unidad esté activada y en “OFF” (APAGADA) cuando la unidad está desactivada, y no se encenderá hasta que la presión del embrague esté completamente activada. Monte el interruptor de activación a la vista del operador. La luz indicadora se debe instalar a la vista del operador mientras este se encuentre en el asiento del conductor del vehículo. Use 36MK1210-A en caso de que se necesite una luz de advertencia adicional.* No instale otros componentes o dispositivos eléctricos en el interruptor de presión de Muncie oel módulo Muncie Start.** La TDF con cambio accionado por embrague requiere conexión al Circuito “PTO Enable Input” (Entrada de activación de la TDF) de Allison en controles Allison de 4ta generación y superiores. Póngase en contacto con Muncie Power o Allison para obtener más detalles. Verifique con el distribuidor del vehículo o la información de fabricantes de carrocerías para obtener la ubicación.

A

B

Para activación integral solenoideCódigo de caraterística especial de la TDF: 6 (12V Muncie Start®)

VALVULA SOLENOIDE ORIENTABLEAPLICAR TORISON 3 PIES-LBS. (2 LUGANES)

INTERRUPTOR DE PRESIÓNAPLICAR TORISÓN A 10-12 PIES-LBS.

CONEXIÓNDE CABLEADO

CONEXIÓNDE CABLEADO

APLICAR TORISÓN A 10-13 PIES-LBS.

AL PUERTODE PRESIÓN INSTALAR EN

ELPUERTO DE PRESIÓN DE LA TRANSMISIÓNVER EL PASO 2

B

360

CONEXIÓNDE CABLEADO

2

A

PUERTO 1PUERTO 2PUERTO 3

PUERTO 4

LUBRICACIÓNEMBRAGUE

ESCAPE

APLICAR A TODOS LOS ACCEROIOS UNA TORISÓN A 10-13 PIES-LBS.

Para activación remota de solenoideCódigo de cambro de la TDF: SR (12VDC Muncie Start®) TR (24VDC Muncie Start®)

VALVULA SOLENOIDE ORIENTABLEAPLICAR TORISÓN 13 PIES-LBS. (2 LUGANES)

INTERRUPTOR DE PRESIÓNAPLICAR TORISÓN A 10-12 PIES-LBS.

CONEXIÓNDE CABLEADO

AL PUERTODE PRESIÓN DE LA TRANSMISIÓN

INSTALAR EN EL PUERTO DE PRESIÓN DE LA TRANSMISIÓNVER EL PASO

ACTIVACIÓN DE LA TDF DE 10 PERNOS CS40/41 MUNCIE START®

Transmisiones de la Serie Allison 3000/4000