Notice

No part of this publication may be reproduced, stored in a retrieval system, translated to another language, or transmitted in any form by any means, electronic, mechanical, photocopied, recorded, or otherwise, without prior written permission.

The information in this document is subject to change. Neither Carestream Health, Inc. nor any of its subsidiaries shall be liable for errors contained herein or for incidental damages in conjunction with the furnishing, performance, or use of this material.

We recommend that you thoroughly familiarize yourself with this Guide in order to make the most effective use of your system.

The CS 3600 Family comprises:• CS 3600• CS 3600 Access

This document refers to all models as CS 3600 unless otherwise specified.

Carestream Health is a trademark of Carestream Health, Inc.

All other trademarks and registered trademarks are the property of their respective holders.

The CS 3600 and CS 3600 Access are intended for professional use only.

US Federal law restricts this device to sale by or on the order of a dentist.

Manual Name: CS 3600 Family User and Installation Guide Part Number: 9J8267 Revision Number: 03 Print Date: 2017 - 09

WARNING: We recommend that you consult the “CS 3600 Family Safety, Regulatory, and Technical Specifications User Guide” before using the CS 3600 family systems.

Page 3: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Contents

Chapter 1 Conventions in This Guide

Conventions in This Guide . . . . . . . . . . . . . . . . . . . 1

Chapter 2 CS 3600 Family Overview

CS 3600 Family Overview . . . . . . . . . . . . . . . . . . . 3

CS 3600 Family Holder Overview . . . . . . . . . . . . . . . 5

CS 3600 Family USB Cable Storage . . . . . . . . . . . . . 6

Chapter 3 CS 3600 Family Software Overview

Minimum Computer System Requirements . . . . . . . . . . 7

General Software Overview . . . . . . . . . . . . . . . . . . 7

Imaging Software . . . . . . . . . . . . . . . . . . . . . 7

Acquisition Interface Overview . . . . . . . . . . . . . . . . . 8

Toolbar Overview . . . . . . . . . . . . . . . . . . . . . 9

Select Acquisition Type Window . . . . . . . . . . . . 13

Preparation Check . . . . . . . . . . . . . . . . . . . . 14

Arch Display . . . . . . . . . . . . . . . . . . . . . . . 14

Preferences Dialog Boxes Overview. . . . . . . . . . . . . 15

Basic General Preferences . . . . . . . . . . . . . . . 15

Advanced General Preferences . . . . . . . . . . . . . 16

Scanner Preferences . . . . . . . . . . . . . . . . . . 17

Tools Preferences . . . . . . . . . . . . . . . . . . . . 18

Chapter 4 Setting Up the Scanner

Setting Up the Scanner . . . . . . . . . . . . . . . . . . . 19

Using the Desktop Holder . . . . . . . . . . . . . . . . . . 21

Installing the Desktop Holder . . . . . . . . . . . . . . 21

Installing the Wall Mount Holder . . . . . . . . . . . . 22

Chapter 5 Getting Started

Using the Imaging Software . . . . . . . . . . . . . . . . . 23

Accessing the Acquisition Interface . . . . . . . . . . . . . 23

Accessing the Acquisition Interface Using the Imaging Software . . . . . . . . . . . . . . . . . . . . 23

Accessing the Acquisition Interface from Your Practice Management Software . . . . . . . . . . . . . 23

Setting Up Preferences . . . . . . . . . . . . . . . . . . . 24

Viewing the Tutorials . . . . . . . . . . . . . . . . . . . . . 24

Tools and Tips . . . . . . . . . . . . . . . . . . . . . . . . 25

Tooth Preparation . . . . . . . . . . . . . . . . . . . . 25

Scanner Position . . . . . . . . . . . . . . . . . . . . . 25

CS 3600 Family User and Installation Guide (9J8267)_Ed03 iii

Page 4: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Important Scanning Procedures— Restoration Acquisition . . . . . . . . . . . . . . . . . . 25

Scanning One Surface at a Time . . . . . . . . . . 25

Scanning Each Tooth Individually . . . . . . . . . . 25

Important Scanning Procedures— Orthodontic Acquisition . . . . . . . . . . . . . . . . . 26

Scanning One Surface at a Time . . . . . . . . . . 26

Scanning Each Tooth Individually . . . . . . . . . . 26

Important Scanning Procedures— Implant Acquisition . . . . . . . . . . . . . . . . . . . . 26

Scanning One Surface at a Time . . . . . . . . . . 26

Scanning Each Tooth Individually . . . . . . . . . . 26

Scanning Metal, Crowns, Holes, or Gaps . . . . . . . . 27

Removing Soft-Tissue Artifacts, Unwanted Views, and Mismatches. . . . . . . . . . . . . . . . . . . . . . 28

Preparing the Scanner. . . . . . . . . . . . . . . . . . . . . 29

Chapter 6 Acquiring a 3D Model for Restoration

Acquiring a 3D Model for Restoration Using the Standard Scan Workflow . . . . . . . . . . . . . . . . . . . . . . . . 31

Scanning Teeth on the Upper and Lower Jaw . . . . . . 31

Scanning the Buccal Bite Registration. . . . . . . . . . 35

Check . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Drawing Margin Lines. . . . . . . . . . . . . . . . . . . 42

Automatically Drawing a Margin Line . . . . . . . . 42

Manually Drawing a Margin Line . . . . . . . . . . . 44

Selecting 2D Images (Optional for CS 3600 Access). . . . 46

Reviewing a Scan and Removing Unwanted Views Using Scan History Check . . . . . . . . . . . . . . . . . . . . . . 47

Acquiring a 3D Model for Restoration Using the Pre & Post Scan Workflow . . . . . . . . . . . . . . . . . . 49

Importing a Previous Scan . . . . . . . . . . . . . . . . 49

Cutting Out the Tooth That Has Been Prepared and Acquiring the Preparation Area. . . . . . . . . . . . . . 51

Check . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Drawing Margin Lines. . . . . . . . . . . . . . . . . . . 59

Automatically Drawing a Margin Line . . . . . . . . 59

Manually Drawing a Margin Line . . . . . . . . . . . 61

Selecting 2D Images (Optional for CS 3600 Access). . . . 63

Reviewing a Scan and Removing Unwanted Views Using Scan History Check . . . . . . . . . . . . . . . . . . . . . . 64

iv

Page 5: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Chapter 7 Acquiring a 3D Model for Orthodontics

Scanning Teeth on the Upper and Lower Jaw . . . . . . . . 67

Scanning the Buccal Bite Registration . . . . . . . . . . . 71

Orthodontic Scan Check . . . . . . . . . . . . . . . . . . . 73

Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

Selecting 2D Images (Optional for CS 3600 Access) . . . 78

Reviewing a Scan and Removing Unwanted Views Using Scan History Check . . . . . . . . . . . . . . . . . . . . . 79

Chapter 8 Acquiring a 3D Model for Implants

Scanning Teeth on the Upper and Lower Jaw . . . . . . . . 82

Scanning the Buccal Bite Registration . . . . . . . . . . . 86

Using the Cutting Tools to Cut Out the Implant Area . . . . 88

Acquiring the Scan Body on the Implant Jaw . . . . . . . . 91

Acquiring Multiple Scan Bodies on the Implant Jaw . . 92

Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Selecting 2D Images (Optional for CS 3600 Access) . . . 97

Reviewing a Scan and Removing Unwanted Views Using Scan History Check . . . . . . . . . . . . . . . . . . . . . 98

Chapter 9 Maintenance

Cleaning, Disinfecting, and Sterilizing . . . . . . . . . . . .101

Chapter 10 Troubleshooting

CS 3600 Family Troubleshooting Instructions . . . . . . .103

Chapter 11 Contact Information

Factory Address . . . . . . . . . . . . . . . . . . . . . . .105

Manufacturer’s Address . . . . . . . . . . . . . . . . . . .105

Authorized Representatives . . . . . . . . . . . . . . . . .105

CS 3600 Family User and Installation Guide (9J8267)_Ed03 v

Page 6: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

vi

Page 7: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

1 Conventions in This Guide

Conventions in This GuideThe following special messages emphasize information or indicate potential risk to personnel or equipment:

Provide Feedback

Did you find the information in this document helpful? Were you looking for information that was not in this document?

Take our short survey and help us make this document better.

Click http://guest.cvent.com/d/sdqtll/3B to open the questionnaire.

WARNING: Warns you to avoid injury to yourself or others by following the safety instructions precisely.

CAUTION: Alerts you to a condition that might cause serious damage.

Important: Alerts you to a condition that might cause problems.

Note: Emphasizes important information.

Tip: Provides extra information and hints.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 1

Page 8: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

2 Chapter 1 Conventions in This Guide

Page 9: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

2 CS 3600 Family Overview

The CS 3600 Family comprises:

• CS 3600• CS 3600 Access

This document refers to all models as the CS 3600 unless otherwise specified.

The CS 3600 family is designed to acquire 3D still images in the following modes:

• Lower jaw• Upper jaw • Buccal bite registration

CS 3600 Family OverviewFigure 1 CS 3600 Family Components Overview

Note: The CS 3600 Access has the same features as the CS 3600, but images are monochrome. You can add color to the CS 3600 Access with an upgrade.

32

4

5

6

7

89

1

CS 3600 Family User and Installation Guide (9J8267)_Ed03 3

Page 10: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

1 Reusable tip There are three types of tips: Normal, facing downward; Side, facing left; and Posterior, facing downward. Note: The posterior tip allows for more comfortable scanning in hard-to-reach areas. The posterior tip is designed for quadrant scanning only and should not be used to scan a complete arch. The removable scanner tips can be autoclaved for up to 20 cycles. After 20 cycles, discard the tip. If you limit the holding time at 134°C to not more than 4 minutes, you can autoclave the tip up to 60 cycles. See the CS 3600 Family Safety, Regulatory, and Technical Specifications User Guide for more information.

2 Mode indicators • Lower jaw scan mode

• Upper jaw scan mode

• Buccal bite registration mode

Note: The mode indicators and the power button blink rapidly if the scanner is overheating.

3 Mode button Press the button to switch between different modes.

4 Power button• Press one second to power ON. • Press three seconds to power OFF.

Power indicator LED:

5 USB connection indicator

The scanner is active.

When the brightness changes gradually from dark to light and light to dark, the scanner is inactive, disconnected, or the tip is not installed.

If the light is blinking rapidly and the Overheating icon is displayed on the Acquisition interface, place the scanner in the holder for 5 to 10 minutes. The scanner will become inactive and cool down.

Power is OFF.

Connected.

Not connected.

4 Chapter 2 CS 3600 Family Overview

Page 11: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

CS 3600 Family Holder OverviewThe holder can be used as a desktop or a wall mount holder. Place the scanner in the holder when you are not using it.

Figure 2 Scanner in Desktop Holder

Figure 3 Scanner in Wall Mount Holder

6 Scanner connector Plugs into the large jack on the end of the power box.

7 USB cable One end of the cable is hard-wired to the power box, and the other end is connected to a USB port on the computer.

8 Power box/cable Connects the scanner to the power adapter.

9 Power adapter One end of the adapter is inserted in the small jack on the power box, and the other end is inserted in the power outlet.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 5

Page 12: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

CS 3600 Family USB Cable StorageTo avoid damaging the USB cable of the scanner, you should loosely coil the cable and avoid creating any sharp kinks, especially in the area where the cable connects to the scanner.

Figure 4 Correct Scanner Cable Storage

Do not wrap the cable around the handle of the scanner or create any sharp bends in the cable.

Figure 5 Incorrect Scanner Cable Storage

Note: The scanner goes into inactive mode when inserted into the holder. To use it again, take it out of the holder.

Note: The scanner goes into inactive mode when left idle for 5 seconds (if set on a desk, for example). To use it again, pick it up.

Note: The Acquisition interface displays a No Tip icon when the tip is removed. To use the scanner again, put on the tip.

Note: When the scanner is idle for more than an hour, it powers off.

6 Chapter 2 CS 3600 Family Overview

Page 13: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

3 CS 3600 Family Software Overview

Minimum Computer System RequirementsFor the minimum computer system requirements, see the CS 3600 Family Safety, Regulatory, and Technical Specifications User Guide.

General Software OverviewThe CS 3600 family system operates with the following software:

• Imaging software• Acquisition interface

Imaging Software

Carestream’s imaging software is a user-friendly working interface that was designed and developed as a common imaging platform for all our dental digital systems.

For more details, see:

• CS Imaging Software online help and the CS Imaging Software Quick User Guide

OR

• CS Orthodontic Imaging software online help and the CS Orthodontic Imaging Quick User Guide

OR

• CS OMS Imaging software online help and the CS OMS Imaging Quick User Guide

Important: It is MANDATORY to check that your computer system configuration is compatible with the computer system requirements for the CS 3600 family software.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 7

Page 14: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Acquisition Interface OverviewThe CS 3600 and CS 3600 Access Acquisition interface enables you to acquire images in two ways:

• Partial arch scan: Several teeth in the preparation area on both the upper and lower jaws, and a buccal bite registration.

• Full arch scan: Upper jaw, lower jaw, and buccal bite registration.

Figure 6 CS 3600 and CS 3600 Access Acquisition Interface Overview

1 Title Bar: Displays:

• Patient’s name and type of acquisition

• Minimizes the Acquisition interface.

• Maximizes or restores down the Acquisition interface.

• Closes the Acquisition interface.

Note: In some cases, you can acquire images of a single arch (partial or full) and not obtain a buccal bite registration (for example, if there are no teeth in the opposing arch), but it is recommended that you acquire both arches and a buccal bite registration when possible.

12

3

4

5

6 7 8

10

9

8 Chapter 3 CS 3600 Family Software Overview

Page 15: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Toolbar Overview

2 Acquisition Step: Displays the current step in the acquisition process.

3 Acquisition Catalog Toolbar: Enables you to select the acquisition mode.

4 General Toolbar: Enables you to change how the 3D model is displayed.

5 Image Toolbar: Enables you to select and manage 3D images.

6 Progress Bar: Indicates the status of the image acquisition process.

7 3D Model Display Screen: Displays the 3D model created from the scan.

8 Navigation Bar: Enables you to move forward or backward in the acquisition process.

9 Video Preview Screen: Displays live video of the scan of the patient’s teeth.

10 Settings Toolbar: Enables you to view tips, export files, set preferences, and access system information and online help.

Acquisition Catalog ToolbarThe acquisition catalog toolbar enables you to select the acquisition mode.

Lower Jaw button: Acquires a 3D image of the lower jaw.

Upper Jaw button: Acquires a 3D image of the upper jaw.

Buccal Bite Registration button: Acquires a 3D image of the bite.

Switch button: Changes the acquisition mode from upper to lower or vice versa, if you accidentally scan teeth on the wrong jaw.

Lower Jaw button: Acquires a 3D image of the scan body in the lower implant jaw when making an implant acquisition.

Upper Jaw button: Acquires a 3D image of the scan body in the upper implant jaw when making an implant acquisition.

General ToolbarThe general toolbar enables you to change how the 3D model is displayed.

True Color button (optional for CS 3600 Access): Displays the 3D model in the actual color of the patient’s hard and soft tissues.

Zoom Fit button: Scales the 3D model to the best size to fit the display region.

Freeze button: Prevents the 3D model from being resized and rotated.

High Resolution button: Displays the 3D model in high resolution before refinement. Note: When using high resolution, the scanning speed is slower, and the hole warning feature is not available.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 9

Page 16: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Image ToolbarThe image toolbar enables you to select and manage images.

Intraoral Image button (optional for CS 3600 Access): Enables you to select two-dimensional intraoral images.

Show Scanning Area button: Displays the arch diagram, enabling you to indicate the teeth that are part of the model. Click the Adult or Child icon to display the appropriate arch, and select the teeth that are in the model, including the upper and lower jaw. Click the Reset button to clear the selection.

Draw Margin Line button: Displays the Margin Line Tools on the toolbar. This button is available when making a restoration acquisition after the model has been refined.

Auto Margin Line button: Draws the margin line automatically on a tooth you select on the model. This button is available when making a restoration acquisition after the model has been refined.

Manual Margin Line button: Enables you to manually draw the margin line on a tooth you select on the model. This button is available when making a restoration acquisition after the model has been refined.

Edit Margin Line button: Enables you to change a margin line on the model. This button is available when making a restoration acquisition after the model has been refined.

Delete Selected Margin Line button: Deletes a margin line that is selected on the model. This button is available when making a restoration acquisition after the model has been refined.

Light button: Activates and deactivates the environment light to enable you to view the mesh details. When using the CS 3600 Access, the Light button enables you to switch between monochromatic color and black/white HD 3D color. This button is available when the Enable HD 3D option is selected on the Advanced tab of the General Preferences window.

Free Cut button: Selects and deletes unwanted data, such as soft tissue, in the image using a free-form shape.

Cut button: Selects and deletes a circular area around the implant. This button is available when making an implant acquisition.

Split button: Displays a split-screen view of the 3D model. In the Pre & Post Scan restoration acquisition workflow, you can view both a pre-prep acquisition and a post-prep acquisition model. In the implant acquisition workflow, you can view an image of the model both with and without the scan body. This button is available when making a restoration or implant acquisition.

Exit button: Closes the split-screen view of the 3D model. This button is available when making a restoration or implant acquisition.

Delete All button: Deletes all views of the current mode.

Undo button: Cancels the last operation.

Reset button: Reverses all deletions and returns to the initial acquisition.

10 Chapter 3 CS 3600 Family Software Overview

Page 17: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Scan History Check button: Enables you to go backward and forward in a 3D model to check the scan. You can remove mismatched/unwanted views and re-scan areas, if necessary.

Undercut Check button: Automatically makes the undercut calculation. The insertion axis for the calculation is based on the current view of the scan. Rotate the mesh to adjust the insertion axis, then click the Undercut Check button, and left-click and drag the mouse to select the teeth to include in the undercut check. This button is available when making a restoration acquisition.

Reselect button: Reselects the teeth to include in the undercut check. This button is available when making a restoration acquisition.

Recalculate button: Recalculates the undercut after you change the insertion path direction. This button is available when making a restoration acquisition.

Measurement button: Enables you to take measurements between selected points on the model. This button is available when making a restoration acquisition.

Create Measurement button: Enables you to select specific points on the model to take a measurement. Note: You can take a maximum of three measurements. This button is available when making a restoration acquisition.

Lock button: Enables you to select and lock an area on the model to prevent it from being updated by additional scanning. For example, you could use this feature to lock retracted gingiva immediately after scanning, as it might collapse and possibly degrade the scan area otherwise. Note: You can lock a maximum of six areas at one time. This button is available when making a restoration acquisition.

Unlock the Last Locked Area button: Unlocks the last area you selected. This button is available when making a restoration acquisition.

Unlock All button: Unlocks all areas that you selected. This button is available when making a restoration acquisition.

Occlusion Pressure button: Displays a range of colors on the model that indicate the degree of calculated occlusion between the maxillar and mandibular teeth.

Quadrant Snapshot button: Displays a preview of five 2D images showing different views of the model. This button is available when making an orthodontic acquisition.

Quadrant Snapshot OK button: Click to export the five JPG images to the patient’s imaging folder. This button is available when making an orthodontic acquisition.

Quadrant Snapshot Cancel button: Click to close the Quadrant Snapshot window. This button is available when making an orthodontic acquisition.

Scan Body Area Selection button: Enables you to select the area in the model where the scan body will be installed (all other areas are highlighted in blue) to prevent an image mismatch that could occur if you are using multiple scan bodies. The scanner will not add information to the highlighted area. Note: You can select only one scan body area at a time. This button is available when making an implant acquisition.

Unselect button: Unselects the scan body area. This button is available when making an implant acquisition.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 11

Page 18: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Next button: Moves to the next step in the acquisition workflow.

Back button: Moves to the previous step in the acquisition workflow.

Done button: Completes the acquisition and opens the Preparation Check window.

Settings ToolbarThe settings toolbar enables you to view tips for using the software, export files, set preferences, and access system information and online help.

Tips button: Enables you to view tips for using certain features of the software. When you select a feature and a tip is available, the tip is displayed briefly and then fades. To view the tip again, click the Tips button.

Export button: Enables you to access the folder to which you want to export the image file. Use the export function to save the acquired images for later use.

Preference Setting button: Accesses the Preferences dialog box.

About button: Accesses system information, including the firmware and software version, and scanner serial number.

Help button: Accesses the online help.

Scanner Status IconsThese icons display the current status of the scanner.

Inactive icon: Indicates the scanner is in the holder or in sleep mode after being idle for 5 seconds.

No Tip icon: Indicates the scanner does not have a tip.

Overheating icon: Indicates the scanner is overheating. If this icon is displayed, place the scanner in the holder for 5 to 10 minutes. The scanner will become inactive and cool down.

Not Connected icon: Indicates the scanner is not connected.

Connect icon: Click to connect the scanner with the Acquisition software. Note: The Connect icon is displayed when you float the cursor over the Not Connected icon.

12 Chapter 3 CS 3600 Family Software Overview

Page 19: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Select Acquisition Type Window

Orthodontics button: Select and click OK to perform an orthodontic acquisition.

Restoration button: Select and click OK to perform a restoration acquisition. Click the drop-down button to select the Standard Scan or Pre & Post Scan workflow.

Implant button: Select and click OK to perform an implant acquisition.

Import button: Select and click OK to access the folder from which you want to import an image file. Use the As Is import option to access an acquisition you have previously saved. Click the drop-down button to select As Orthodontics, As Restoration, or As Implant to import any previously saved acquisition type as the selected acquisition type. For example, by selecting As Orthodontics, you can import a restoration scan and use it in the orthodontic workflow.

Note: The acquisition type or folder path you select is selected by default the next time you open the Acquisition interface.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 13

Page 20: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Preparation Check

The Preparation Check window is displayed after the model has been refined and enables you to verify important restoration data before continuing with the process.

Arch Display

The Arch Display section is displayed after the model has been refined and enables you to view or

hide the upper and lower jaws.

Restoration Preparation Check: A list of items you must check on the restorative 3D model to verify the bite registration and preparation design. You must examine the appropriate area of the 3D model and select the corresponding option from the list before you can move to the next step. Verify the following:•Occlusal space•Undercut•Margin line

Orthodontic Preparation Check: A list of items you must check on the orthodontic 3D model to verify the accuracy of the model before sending it to the imaging software.You must examine the appropriate area of the 3D model and select the corresponding option from the list before you can move to the next step.Verify the following:•No holes in the image•Jagged boundaries removed•Irregular soft tissue removed

Implant Preparation Check: A list of items you must check on the implant 3D model to verify the accuracy of the model before sending it to the imaging software.You must examine the appropriate area of the 3D model and select the corresponding option from the list before you can move to the next step.Verify the following:•Entire scan body is visible•Bite•Gum tissue is captured correctly•Adjacent teeth are captured

Upper: Click the Upper Jaw button to view or hide the upper jaw.Lower: Click the Lower Jaw button to view or hide the lower jaw.

Note: The acquisition type or folder path you select is selected by default the next time you open the Acquisition interface.

14 Chapter 3 CS 3600 Family Software Overview

Page 21: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Preferences Dialog Boxes OverviewThe Preferences dialog boxes enable you to select the Acquisition interface settings. It is recommended that you set up your preferences before using the scanner.

Basic General Preferences

Figure 7 Basic General Preferences

The Basic General Preferences tab enables you to select these options:

• Language: Select the menu language.

• Help Language: Select the online help system language.

• Override Background: Select the background color you prefer.

Without Scan Body: Click the Without Scan Body button to view the jaw without the scan body.

With Scan Body: Click the With Scan Body button to view the jaw with the scan body.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 15

Page 22: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Use Gradient Background: Select to include color gradations in the background.

• Tutorials on: Select this option and re-start the Acquisition software to view brief tutorials on the interface and scanning techniques.

Advanced General Preferences

Figure 8 Advanced General Preferences

The Advanced General Preferences tab enables you to select these options:

• Enable HD 3D: Select to enable HD 3D. Note: De-selecting the high-definition option can shorten the refinement time.

• Enable Hole Filling: Select to enable the software to fill holes in the model after refinement.

• Enable Adaptive Hole Filling Color (optional for CS 3600 Access): Select to enable the software to use a neighboring color to fill a hole. Note: This option is available only when Enable HD 3D and Enable Hole Filling are selected.

• Hole Filling Color (optional for CS 3600 Access): Select the color used to highlight the filled holes after refinement.

• Brightness (optional for CS 3600 Access): Select the brightness level of the model. Note: This option is available only when Enable HD 3D is selected.

• Enable Orthodontic Scan Check: Select to enable the orthodontic scan check, which gives you the opportunity to verify that all tooth surfaces and essential soft tissue have been acquired before refining the image. If necessary, you can re-scan areas missing information

16 Chapter 3 CS 3600 Family Software Overview

Page 23: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

before continuing with the Check step. Note: You can select this preference only in the orthodontic acquisition mode.

• Enable Implant Refinement Check: Select to enable the implant refinement check, which gives you the opportunity to check the image refinement before cutting out the implant area. Note: You can select this preference only in the implant acquisition mode.

• Enable Data Recovery: Select this option to have the software display a message in the event of an unexpected shutdown, asking if previous data should be recovered. If the user selects Yes, the last scan is displayed.

• Auto Save .CSZ File: Select to save a copy of the raw data for a scan in the designated folder.

Use the following options:

• Select Folder: Click to navigate to the folder to which you want to save the .CSZ file.

• Open File Location: Click to open the folder containing the .CSZ files.

Scanner Preferences

Figure 9 Scanner Preferences

The Scanner Preferences window enables you to select the following options:

• Capture Beep: Select to enable a beeping sound each time a scan starts and stops. One beep indicates scanning is in progress; two beeps indicate that the scan has stopped, and you must re-scan a previously scanned area to begin again. A single beep also indicates you have successfully captured a buccal bite image.

• Default Acquisition Catalog: Select the jaw you will always scan first.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 17

Page 24: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Tools Preferences

Figure 10 Tools Preferences

The Tools Preferences window enables you to select the following options:

• Create Support File: Click to select the folder where the log files for service information are saved.

• Renew License: Click to renew your software license. Refer to the instructions inside the license voucher.

18 Chapter 3 CS 3600 Family Software Overview

Page 25: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

4 Setting Up the Scanner

Setting Up the ScannerTo set up the scanner, follow these steps:

1 Install the imaging software on the computer. To install the CS Imaging Software, CS Orthodontic Imaging software, or CS OMS Imaging software, see the relevant installation and quick user guides.

2 Insert the CS 3600 Family Installation Wizard flash drive into the USB drive. The AutoPlay

window is displayed.

3 Select Run wizard.exe. The Autorun window is displayed.

4 Select a language from the drop-down list, and click Run Installation. The Installation Wizard window is displayed.

5 Follow the on-screen instructions to complete the installation.

6 Firmly slide one of the tips onto the end of the scanner.

Note: If the AutoPlay window does not automatically display, navigate to the CS 3600 Family flash drive in Windows Explorer and double-click wizard.exe.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 19

Page 26: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

7 Insert the scanner connector (A) into the large jack on the end of the power box (B), and insert the DC power supply (C) into the small jack on the power box. Connect the USB cable (D) to the computer. and insert the power adapter (E) into an outlet.

8 Press the power button one second to power on the scanner. Ensure the power indicator turns blue.

9 Wait until the USB connection indicator turns blue.

Note: The power indicator stops blinking and remains blue when the acquisition interface is open and the scanner is ready to acquire images.

20 Chapter 4 Setting Up the Scanner

Page 27: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Using the Desktop HolderThe holder can function either as a desktop holder or a wall mount holder.

Installing the Desktop Holder

To use the holder as a desktop holder, follow these steps:

1 Select a clean surface area that you can access easily.

2 Clean the surface on which you are going to fasten the holder.

3 Attach the adhesive tape to the indentations in the holder (A).

4 Remove the adhesive tape protection (B).

5 Place the taped side of the holder on the clean surface (C) and press firmly several times for correct adherence. The maximum adherence is obtained after two hours.

Important: You must avoid all stress on the holder during the first two hours.

Important: Adhesive tape can lose its adherence capability due to environmental and other factors. Check the adherence regularly to ensure that it is secure.

Important: Carestream Health is not responsible for accidents or damage involving the scanner falling due to loosening of the adhesive tape.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 21

Page 28: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Installing the Wall Mount Holder

To use the holder as a wall mount holder, follow these steps:

1 Select an area that you can access easily.

2 Insert screws through the appropriate holes in the holder to affix it to a solid surface.

Important: If the holder is not properly installed, there is a risk that the holder can fall off the wall, resulting in damage to the scanner.

22 Chapter 4 Setting Up the Scanner

Page 29: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

5 Getting Started

Using the Imaging SoftwareTo use the CS Imaging Software, see the CS Imaging Software Quick User Guide and the online help delivered with the software.

To use the CS Orthodontic Imaging software, see the CS Orthodontic Imaging Quick User Guide and the online help delivered with the software.

To use the CS OMS Imaging software, see the CS OMS Imaging Quick User Guide and the online help delivered with the software.

Accessing the Acquisition InterfaceYou can access the Acquisition interface from inside the CS Imaging Software, the CS Orthodontic Imaging software, the CS OMS Imaging software, or from inside your practice management software.

Accessing the Acquisition Interface Using the Imaging Software

To access the Acquisition interface from the CS Imaging Software, the CS Orthodontic Imaging software, or the CS OMS Imaging software, follow these steps:

1 On your desktop, double-click (Carestream’s CS Imaging Software, CS Orthodontic

Imaging software, or CS OMS Imaging software).

2 Find or create the patient record.

3 Double-click the patient record to access the imaging window or tab.

4 In the imaging window or tab, click to open the Acquisition interface.

5 Select your preference settings.

Accessing the Acquisition Interface from Your Practice Management Software

To access the Acquisition interface from your practice management software, follow these steps:

1 Open your practice management software.

2 Find the patient record and open it.

3 Open the imaging software.

4 Click to open the Acquisition interface.

5 Select your preference settings.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 23

Page 30: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Setting Up PreferencesSet up your preferences before using the scanner. To set up the preferences, follow these steps:

1 On the Acquisition interface, click . The Preferences dialog box is displayed.

2 Click to set the general preferences.

3 Click to set the scanner preferences.

4 Click to set the tools preferences.

You can now start acquiring 3D images.

Viewing the TutorialsTo help you become familiar with the Acquisition interface and scanning techniques, you can view several brief tutorials. These tutorials are displayed the first time you open the software. After you view the tutorials and click End Tutorial, the tutorials will no longer display. You can view the tutorials again at any time by selecting the tutorials option on the Basic General Preferences tab.

To enable the tutorials, follow these steps:

1 In the Acquisition interface, click . The Basic General Preferences tab is displayed.

2 Click Tutorials on.

3 Click Apply, click OK, and close the Acquisition interface.

4 Reopen the Acquisition interface to view the tutorials.

24 Chapter 5 Getting Started

Page 31: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Tools and TipsUse the following tools and tips to help you acquire quality images:

• Capture Beep: When the capture beep feature is enabled, the scanner beeps one time when the acquisition starts and two times when the acquisition stops due to incorrect scanning. To continue, go back to a previously scanned area until the scanner beeps one time and resume scanning. A single beep also indicates you have successfully captured a buccal bite image.

Tooth Preparation• Dry the teeth thoroughly before starting an acquisition.

• Re-dry the teeth as appropriate throughout the acquisition process.

Scanner Position• To enable the antifog feature, place the tip on the scanner and allow the scanner to warm up

for approximately three minutes before starting the acquisition.

• Rest the tip of the scanner on the tooth surface to steady the scanner.

• To start the scanner, hold the scanner until the first 3D image appears, then move along with the arch.

Important Scanning Procedures—Restoration Acquisition

Scanning One Surface at a Time

• Start with the occlusal surface, beginning with the preparation area and then scanning the surrounding teeth on the jaw.

• Next, scan the lingual surface, starting with the preparation area and then scanning the surrounding teeth on the jaw.

• Scan the buccal surface, starting with the preparation area and then scanning the surrounding teeth on the jaw.

• Finally, acquire the buccal bite registration.

Scanning Each Tooth Individually

• Scan one tooth at a time, following the occlusal/lingual/buccal, buccal/occlusal/lingual, or lingual/occlusal/buccal scan path.

• Once the entire tooth is scanned, move to the next tooth and repeat the scanning process until you have scanned all the teeth in the preparation area, as well as the surrounding teeth on the jaw.

• Finally, acquire the buccal bite registration.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 25

Page 32: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Important Scanning Procedures—Orthodontic Acquisition

Scanning One Surface at a Time

• Start with the occlusal surface, and scan the teeth on the jaw.

• Next, scan the lingual surface of the teeth and soft-tissue areas. Be sure to include several millimeters of gingival tissue in the lingual scan.

• Scan the buccal surface of the teeth, palate, and soft-tissue areas. Be sure to include several millimeters of gingival tissue in the buccal scan.

• Finally, acquire the buccal bite registration.

Scanning Each Tooth Individually

• Scan one tooth at a time—following the occlusal/lingual/buccal, buccal/occlusal/lingual, or lingual/occlusal/buccal scan path—and include the palate and soft-tissue areas. Be sure to include several millimeters of gingival tissue in the lingual and buccal scans.

• Once the entire tooth and surrounding areas are scanned, move to the next tooth and repeat the scanning process until you have scanned all the teeth, the palate, and the soft-tissue areas. Be sure to include several millimeters of gingival tissue in the lingual and buccal scans.

• Finally, acquire the buccal bite registration.

Important Scanning Procedures—Implant Acquisition

Scanning One Surface at a Time

• Start with the occlusal surface, beginning with the implant area and then scanning the surrounding teeth on the jaw.

• Next, scan the lingual surface, starting with the implant area and then scanning the surrounding teeth on the jaw.

• Scan the buccal surface, starting with the implant area and then scanning the surrounding teeth on the jaw.

• Finally, acquire the buccal bite registration.

Scanning Each Tooth Individually

• Scan one tooth at a time, following the occlusal/lingual/buccal, buccal/occlusal/lingual, or lingual/occlusal/buccal scan path.

• Once the entire tooth is scanned, move to the next tooth and repeat the scanning process until you have scanned all the teeth in the implant area, as well as the surrounding teeth on the jaw.

• Finally, acquire the buccal bite registration.

26 Chapter 5 Getting Started

Page 33: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Scanning Metal, Crowns, Holes, or Gaps

• When scanning metal amalgams and crowns, thoroughly dry the teeth before scanning.

• Adjust the operatory light away from the patient to decrease light scatter.

• If holes are displayed in the scanned image near the restoration area, re-scan the area until the holes are filled. Holes away from the restoration area are not of great concern. To better view

any holes, turn off True Color by clicking (optional for CS 3600 Access). Then, place

the cursor over the 3D image, left-click and hold to rotate the model. Use the mouse wheel to zoom in on the 3D model.

• A yellow color on the 3D model indicates gaps that might cause image connecting errors.

Continue scanning the area until the yellow disappears.

• A green line with a red arrow indicates a weak connection among buccal, lingual, and occlusal surfaces that might cause an image stitching error, especially on incisor teeth.

Continue scanning the area until the arrows disappear. The arrows indicate the scanning path you should use to capture the missing information.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 27

Page 34: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• If you are not using the high resolution mode during acquisition, a green color on the 3D model highlights existing holes in the image.

Re-scan the highlighted areas until the green is gone.

Removing Soft-Tissue Artifacts, Unwanted Views, and Mismatches

• If you detect soft-tissue artifacts in an image during acquisition, click and left-click at

several points around the soft tissue to draw lines around it. Double-click to delete the soft tissue. Re-scan the area to fill any holes.

• You can also remove soft-tissue artifacts, mismatches, or unwanted views by using the scan history check feature, which enables you to return to the portion of the scan just prior to where

the unwanted views or mismatch occurred. Then you can re-scan the area. Click . Click on the slider and drag it to the left to remove portions of the scan. When you have removed the unwanted views from the scan, click OK to return to the Acquisition window.

28 Chapter 5 Getting Started

Page 35: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Preparing the ScannerThe reusable tip attaches to the body of the scanner and provides a sanitary shield for the patient. Always disinfect the body of the scanner, and clean and sterilize the tip after each use.

To prepare the scanner, follow these steps:

1 Make sure the lens window at the base of the scanner is clean by wiping it with a moist, lint-free cloth or lens tissue.

2 Slide the tip onto the scanner as illustrated, with the lens facing downward (A) or to the side, facing left (B).

Important: Scanner tips received from the manufacturer are NOT sterilized. You must sterilize the tips before the first use.

Important: The removable scanner tips can be autoclaved for up to 20 cycles. After 20 cycles, discard the tip. If you limit the exposure time at 134°C to not more than 4 minutes, you can autoclave the tip up to 60 cycles. See the CS 3600 Family Safety, Regulatory, and Technical Specifications User Guide for more information.

WARNING: The base of the scanner becomes heated when the scanner is turned on. Do not touch the heating element at the base of the scanner.

Important: Use the posterior tip in hard-to-reach areas and for quadrant scanning only. Use the normal tip or the side-facing tip when scanning a full arch.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 29

Page 36: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

3 Press the power button for one second to power on the scanner.

4 Let the scanner warm up for approximately three minutes to enable the antifog feature on the tip.

30 Chapter 5 Getting Started

Page 37: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

6 Acquiring a 3D Model for Restoration

You can use the Standard Scan restoration workflow to scan either a partial or full arch. For either type of scan, you should acquire images of the upper jaw, lower jaw, and the buccal bite registration. The software combines these images to create a 3D model.

To acquire a 3D model, follow these procedures:

• Scan the upper and lower jaw.• Scan the buccal bite registration.• Refine the image.• Complete the preparation check and export the image.

An alternate restoration scanning workflow—Pre & Post Scan—is also available. The Pre & Post Scan workflow enables you to take a new scan of a tooth, then prep the tooth and take another scan of the preparation. Or you can combine a scan you have taken previously with a new scan of the preparation area. With either Pre & Post Scan option, the output DCM file contains four mesh files—two files containing the unprepared tooth, and two containing the preparation. You or the lab can use the files with the unprepared tooth as a reference when designing the restoration. See “Acquiring a 3D Model for Restoration Using the Pre & Post Scan Workflow” on page 49 for more information.

Acquiring a 3D Model for Restoration Using the Standard Scan Workflow

Scanning Teeth on the Upper and Lower Jaw

To acquire images using auto acquisition, follow these steps:

1 Dry the teeth thoroughly before starting an acquisition.

2 Access the Acquisition interface by clicking in the imaging software.

3 On the button in the Select Acquisition Type window, click the drop-down button to

select , and click OK.

4 On the Acquisition interface, select the Upper Jaw acquisition mode.

OR

Note: In some cases, you can acquire images of a single arch (partial or full) and not obtain a buccal bite registration (for example, if there are no teeth in the opposing arch), but it is recommended that you acquire both arches and a buccal bite registration when possible.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 31

Page 38: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

On the scanner, press the mode button for one second to select the acquisition mode. The mode

indicator LED turns blue.

5 Hold the scanner at a 90-degree angle to the occlusal surface of the teeth. Rest the tip on the tooth surface to steady the scanner. Live video is displayed on the video preview screen, and the acquisition begins. Images are automatically acquired and transferred to the 3D model display screen.

The image below shows several acquisitions of the upper jaw.

6 Slowly move the scanner tip along the occlusal surface to scan the remaining teeth in the preparation area.

7 When the occlusal surface scan is complete, scan the lingual surface of the teeth in the preparation area.

Important: A green line with a red arrow indicates a weak connection among buccal, lingual, and occlusal surfaces that might cause an image stitching error, especially on incisor teeth. Scan the area until the arrows disappear.

32 Chapter 6 Acquiring a 3D Model for Restoration

Page 39: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

8 When the lingual surface scan is complete, scan the buccal surface of the preparation area.

The example below shows a 3D model of the upper jaw when the occlusal, lingual, and buccal

surfaces have been completely scanned.

If necessary, you can lock a portion of a scanned area to prevent it from being updated by

additional scanning. For example: You could use this feature to lock retracted gingiva immediately

after scanning, as it might collapse and possibly degrade the scan area.

• Click and click the mouse on several points around the area.

• Double-click the mouse. The selected area turns blue, and the scanner will not add information to the locked (blue) area, if scanned.

• You can lock additional areas (up to a maximum of six) by repeating these steps.

Important: Re-dry the teeth as appropriate throughout the acquisition process.

Important: If holes are displayed in the scanned image on the preparation area, re-scan the area until the holes are filled. Use the mouse wheel to zoom in on the preparation area for a closer look.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 33

Page 40: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click to unlock the last area you selected.

• Click to unlock all of the areas you selected.

9 Once the upper jaw has been scanned, you can begin scanning the lower jaw. Click and

repeat steps 5 through 8 until the teeth in the area of restoration on the lower jaw are scanned.

The example below shows a 3D model of the lower jaw when the occlusal, lingual, and buccal

surfaces have been completely scanned.

10 Visually inspect the 3D model for any holes. If holes are present near the restoration area, re-scan the area until the holes are filled.

If you are not using the high resolution mode during acquisition, a green color on the 3D model

highlights existing holes in the image.

Re-scan the highlighted areas until the green is gone.

11 When you are satisfied with the 3D model, continue with the buccal bite registration acquisition.

Important: If you acquire images of teeth from both the upper and lower jaw, you must also acquire the buccal bite registration.

34 Chapter 6 Acquiring a 3D Model for Restoration

Page 41: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Scanning the Buccal Bite Registration

To acquire a buccal bite registration using auto acquisition, follow these steps:

1 Click .

2 Have the patient bite down.

3 Position the scanner at a 90-degree angle to the buccal surface of the preparation area, and align the point where the upper and lower teeth meet in the middle of the video preview screen. Rest the tip on the tooth surface to help steady the scanner.

4 Move the scanner slightly up and down to trigger the bite registration acquisition. If you have enabled the Capture Beep option in the Scanner Preferences window, a single beep indicates a successful capture.

The example below shows a buccal bite registration.

A dot is displayed at the bottom of the window to indicate the capture was successful. A

successful bite image includes both the upper and lower arch.

Once both arches are displayed in the Acquisition interface, the bite image is successful, and you

can acquire additional bite images, which will increase the accuracy of the bite.

Tip: After acquiring the buccal image of one jaw, always move toward the opposing arch with the scanner.

Important: For a partial arch, you should acquire at least three buccal bite images—one on the preparation, one mesial to the preparation, and one distal to the preparation. For a full arch, you should acquire at least four buccal bite images—one on each side of the mouth at the molars, and one on each side of the mouth at the canines.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 35

Page 42: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

5 Acquire at least two more buccal bite images, one on either side of the preparation area. You can take up to six bite images for a full arch.

6 Once the bite has been registered, rotate the model and zoom the view to ensure that the bite is accurate and that there are no areas where the bite is mismatched. Click a dot to view the bite for that acquisition.

The example below shows several buccal bite registrations.

7 Click . The arch diagram is displayed.

8 Click the Adult or Child icon to display the appropriate arch.

9 Select the teeth on the arch that were acquired for the 3D model, including those on the upper and lower jaw.

10 When you have finished selecting the teeth in the scanning area, proceed to the check step.

36 Chapter 6 Acquiring a 3D Model for Restoration

Page 43: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Check

The check step enables you to further process the 3D image to obtain the highest accuracy. You can use several tools to closely examine the 3D model and verify undercut, occlusion, and distances between points in the mouth.

To refine the 3D model and further examine it, follow these steps:

1 Click to refine the image.

2 Manipulate the refined 3D model using the following methods:

• Right-click and hold on the 3D model to move it in the window.• Left-click and hold on the 3D model to rotate it.• If your mouse has a scroll wheel, use the wheel to zoom in or zoom out on the 3D model.

• Click to turn on the environment light.

• Click to scale the model to its best view.

• Click or to hide the upper or lower jaw. Click the button again to

restore the view of the jaw.

Tip: When the light is on, a shadow appears, increasing the 3D effect and helping you to see the mesh. When the light is off, the shadow disappears, making the mesh brighter and helping you to see color and details.

Note: When using the CS 3600 Access, the Light button enables you to switch between monochromatic color and black/white HD 3D color.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 37

Page 44: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click to select and delete excess soft tissue in the image.

• Rotate the mesh to adjust the insertion axis, and click to view the undercut.

• Left-click and drag the mouse to select the teeth to include in the undercut check. The undercut is displayed.

• Click to select a different area.

• Click to recalculate the undercut after you have changed the insertion path

direction.

• Click to close the undercut tool and continue with the check process.

• Click to view the occlusion pressure, displayed as a range of color on the mesh.

38 Chapter 6 Acquiring a 3D Model for Restoration

Page 45: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Zoom in on the model to view a clear indication of how

occlusion is calculated in the model.

• Click to close the occlusion pressure tool and continue with the check

process.

• Click to take a measurement between selected points on the 3D model.

• Click on the top of a tooth, and move the slider to rotate the cutting plane.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 39

Page 46: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click in the Measurement Tools section, and select two points on the

rendering in the right panel to view the measurement. You can repeat this process to take up to three measurements at one time.

• Press Esc to reset the measurement tool.

• Click to close the measurement tool and continue with the check process.

3 If you find holes in the preparation area, click and re-scan the teeth that are missing

data.

4 Repeat steps 1 through 3 until you are satisfied with the 3D model.

5 If you are exporting the 3D model to a dental lab, you can draw a margin line reference on the 3D model. See “Drawing Margin Lines.”

6 Click . The Preparation Check window is displayed.

40 Chapter 6 Acquiring a 3D Model for Restoration

Page 47: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

7 Examine the occlusal space on the 3D model and do one of the following:

• If the occlusal space is acceptable, click the corresponding option in the Preparation Check window.

• If the occlusal space is not acceptable, click Cancel. Click and re-scan the

affected teeth.

8 Examine the undercut on the 3D model and do one of the following:

• If the undercut is acceptable, click the corresponding option in the Preparation Check window.

• If the undercut is not acceptable, click Cancel. Click . Make the necessary

adjustments to the preparation and then re-scan the preparation area and surrounding teeth.

9 Examine the margin line on the 3D model and do one of the following:

• If the margin line is acceptable, click the corresponding option in the Preparation Check window.

• If the margin line is not acceptable, click Cancel. Click and re-scan the

affected teeth.

10 When satisfied with the 3D model, click to send the 3D model to the imaging

software.

Important: To view your 3D models, use the CS Mesh Viewer that was installed on your desktop. For instructions on using the mesh viewer, click the ? button in the CS Mesh Viewer interface. If you are sending the DCM file to a lab, ask the lab to download the CS Mesh Viewer from the following link: http://sas-origin.onstreammedia.com/origin/carestreamhealthinc/CSMeshViewer/CSMeshViewer.zip

CS 3600 Family User and Installation Guide (9J8267)_Ed03 41

Page 48: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Drawing Margin Lines

If you are exporting the 3D model to a dental lab, you can have the software automatically draw a margin line on the 3D model, or you can manually draw the margin line.

Automatically Drawing a Margin Line

To automatically draw a margin line, follow these steps:

1 Click . The Margin Line Tools are displayed on the toolbar.

2 Click .

Important: The Auto Margin Line feature can be used only with crowns. For cases involving inlays or onlays, you must manually draw the margin line.

42 Chapter 6 Acquiring a 3D Model for Restoration

Page 49: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

3 Click on the preparation area. The tooth number selection arch diagram is displayed.

4 Select the corresponding tooth on the tooth number selection arch diagram.

5 Examine the margin line on the 3D model and do any of the following:

• To edit the margin line, click on the margin line to select it. Click . Redraw the

section of the margin line you want to alter, and be sure it connects with the existing margin line.

• To delete the margin line, select the margin line and click .

6 To view margin line references outside of the Acquisition interface, use the CS Mesh Viewer that was installed on your desktop.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 43

Page 50: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Manually Drawing a Margin Line

You must manually draw the margin line if the case involves an inlay or onlay.

To manually draw a margin line, follow these steps:

1 Click . The Margin Line Tools are displayed on the toolbar.

2 Click . The tooth number selection arch diagram is displayed.

3 Select the corresponding tooth on the tooth number selection arch diagram.

44 Chapter 6 Acquiring a 3D Model for Restoration

Page 51: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

4 Left-click and drag to draw the margin line around the preparation.

5 Examine the margin line on the 3D model and do any of the following:

• To edit the margin line, click on the margin line to select it. Click . Redraw the

section of the margin line you want to alter, and be sure it connects with the existing margin line.

• To delete the margin line, click on the margin line to select it. Click .

6 To view margin line references outside of the Acquisition interface, use the CS Mesh Viewer that was installed on your desktop.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 45

Page 52: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Selecting 2D Images (Optional for CS 3600 Access)You can select 2D images from the 3D model to send to the dental lab along with the 3D model.

To select 2D images, follow these steps:

1 Click .

2 Manipulate the 3D model to the position you want to view.

3 Click on the areas of the 3D model for which you want 2D images. The images are displayed on the Views tab.

4 Click the checkmark on the upper-right corner of an image on the Views tab to move the image to the Saved Views tab.

5 When you are finished selecting 2D images, click to return to the Acquisition interface.

Note: The 2D image selection feature is available only during the acquisition step.

46 Chapter 6 Acquiring a 3D Model for Restoration

Page 53: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Reviewing a Scan and Removing Unwanted Views Using Scan History CheckThe scan history check feature enables you to go backward and forward in a 3D model to check the scan. If you have areas of the scan containing mismatched or unwanted views, and you cannot remove

these areas using the tool, you can use the scan history check feature to return to the portion of

the scan just prior to where the mismatch occurred. Then you can re-scan the area.

To use the scan history check feature, follow these steps:

1 Click . The scan history check view is displayed.

2 Manipulate the 3D model to the position you want to view.

3 Click on the slider, and drag it to the left to remove portions of the scan. Moving the slider back to the right replaces the portions you removed.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 47

Page 54: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

4 When you have removed the unwanted views from the scan, click OK to return to the Acquisition window.

5 To return to the Acquisition window without making any changes, click Cancel.

Note: Views removed using the scan history check feature cannot be restored.

48 Chapter 6 Acquiring a 3D Model for Restoration

Page 55: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Acquiring a 3D Model for Restoration Using the Pre & Post Scan WorkflowDepending on how your practice uses the scanner and your workflow preferences, you can use an alternate scanning workflow—Pre & Post Scan. This workflow gives you two options:

• You can take a new scan of a tooth, then prep the tooth and take another scan of the preparation.

• You can combine a scan you have taken previously with a new scan of the preparation.

With either option, when you have completed the acquisition, the output DCM file contains four mesh files—two files containing the unprepared tooth, and two containing the preparation. You or the lab can use these files to make a restoration that more closely resembles the original tooth.

This example will describe how to combine a scan you have taken previously with a new scan of the preparation. Follow these procedures:

• Import a scan taken before the tooth was prepared.• Cut out the tooth that has been prepared.• Re-scan the preparation area.• Refine the image.• Complete the preparation check and export the image.

Importing a Previous Scan

1 Dry the teeth thoroughly before starting an acquisition.

2 Access the Acquisition interface by clicking in the imaging software.

3 On the button in the Select Acquisition Type window, click the drop-down button to

select , and click OK. A window is displayed, asking if you want to start a

new scan.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 49

Page 56: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

4 Click No to use an existing scan. The Import a scan before preparation window is displayed.

5 Select the .CSZX file you want to import, and click Open. The 3D model is displayed on the Pre-Prep Acquisition tab.

50 Chapter 6 Acquiring a 3D Model for Restoration

Page 57: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

6 Click . The arch diagram is displayed.

7 Click the Adult or Child icon to display the appropriate arch.

8 Select the teeth on the arch that were acquired for the 3D model, including those on the upper and lower jaw.

9 When you have finished selecting the teeth in the scanning area, proceed to the Post-Prep Acquisition step to cut out the prepared tooth and acquire the preparation area.

Cutting Out the Tooth That Has Been Prepared and Acquiring the Preparation Area

1 Click . The 3D model is displayed on the Post-Prep Acquisition tab.

2 Adjust the position of the model so you can clearly view the tooth to be prepared, and click .

Click the mouse at several points around the tooth to be prepared to form a circle big enough to surround the tooth.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 51

Page 58: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

3 Double-click the mouse.

4 Re-scan the jaw, concentrating on the area containing the preparation area. Repeat the steps for acquiring an image as described in “Scanning Teeth on the Upper and Lower Jaw” on page 31.

If necessary, you can lock a portion of a scanned area to prevent it from being updated by

additional scanning. For example: You could use this feature to lock retracted gingiva immediately

after scanning, as it might collapse and possibly degrade the scan area.

Note: If you removed too much of the image, click to restore the image and repeat the cutting process.

52 Chapter 6 Acquiring a 3D Model for Restoration

Page 59: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click and click the mouse on several points around the area.

• Double-click the mouse. The selected area turns blue, and the scanner will not add information to the locked (blue) area, if scanned.

• You can lock additional areas (up to a maximum of six) by repeating these steps.

• Click to unlock the last area you selected.

• Click to unlock all of the areas you selected.

5 When you have successfully scanned the prepped tooth and are satisfied with the image, continue with the check step.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 53

Page 60: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Check

The check step enables you to further process the 3D image to obtain the highest accuracy.

To refine the 3D model and further examine it, follow these steps:

1 Click to refine the image. The model is displayed in a split-screen view.

2 Manipulate both images in the split-screen view at the same time using the following methods:

• Right-click and hold on the 3D model to move it in the window.• Left-click and hold on the 3D model to rotate it.• If your mouse has a scroll wheel, use the wheel to zoom in or zoom out on the 3D model.

• Click to turn on the environment light.

• Click to scale the model to its best view.

• Click or to hide the upper or lower jaw. Click the button again to

restore the view of the jaw.

• Click or to leave the split-screen view, which enables you to modify the

3D model. Images in the split-screen view cannot be modified.

Tip: When the light is on, a shadow appears, increasing the 3D effect and helping you to see the mesh. When the light is off, the shadow disappears, making the mesh brighter and helping you to see color and details.

Note: When using the CS 3600 Access, the Light button enables you to switch between monochromatic color and black/white HD 3D color.

54 Chapter 6 Acquiring a 3D Model for Restoration

Page 61: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click to select and delete excess soft tissue in the image.

• Rotate the mesh to adjust the insertion axis, and click to view the undercut.

• Left-click and drag the mouse to select the teeth to include in the undercut check. The undercut is displayed.

• Click to select a different area.

• Click to recalculate the undercut after you have changed the insertion path

direction.

• Click to continue with the check process.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 55

Page 62: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click to view the occlusion pressure, displayed as a range of color on the mesh.

• Zoom in on the model to view a clear indication of how

occlusion is calculated in the model.

• Click to close the occlusion pressure tool and continue with the check

process.

• Click to take a measurement between selected points on the 3D model.

56 Chapter 6 Acquiring a 3D Model for Restoration

Page 63: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click on the top of a tooth, and move the slider to rotate the cutting plane.

• Click in the Measurement Tools section, and select two points on the

rendering in the right panel to view the measurement. You can repeat this process to take up to three measurements at one time.

• Press Esc to reset the measurement tool.

• Click to close the measurement tool and continue with the check process.

3 If you find holes in the preparation area, click and re-scan the teeth that are missing

data.

4 Repeat steps 1 through 3 until you are satisfied with the 3D model.

5 If you are exporting the 3D model to a dental lab, you can draw a margin line reference on the 3D model. See “Drawing Margin Lines.”

CS 3600 Family User and Installation Guide (9J8267)_Ed03 57

Page 64: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

6 Click . The Preparation Check window is displayed.

7 Examine the occlusal space on the 3D model and do one of the following:

• If the occlusal space is acceptable, click the corresponding option in the Preparation Check window.

• If the occlusal space is not acceptable, click Cancel. Click and re-scan the

affected teeth.

8 Examine the undercut on the 3D model and do one of the following:

• If the undercut is acceptable, click the corresponding option in the Preparation Check window.

• If the undercut is not acceptable, click Cancel. Click . Make the necessary

adjustments to the preparation and then re-scan the preparation area and surrounding teeth.

9 Examine the margin line on the 3D model and do one of the following:

• If the margin line is acceptable, click the corresponding option in the Preparation Check window.

• If the margin line is not acceptable, click Cancel. Click and re-scan the

affected teeth.

10 When satisfied with the 3D model, click to send the 3D model to the imaging

software.

Important: To view your 3D models, use the CS Mesh Viewer that was installed on your desktop. For instructions on using the mesh viewer, click the ? button in the CS Mesh Viewer interface. If you are sending the DCM file to a lab, ask the lab to download the CS Mesh Viewer from the following link: http://sas-origin.onstreammedia.com/origin/carestreamhealthinc/CSMeshViewer/CSMeshViewer.zip

58 Chapter 6 Acquiring a 3D Model for Restoration

Page 65: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Drawing Margin Lines

If you are exporting the 3D model to a dental lab, you can have the software automatically draw a margin line on the 3D model, or you can manually draw the margin line.

Automatically Drawing a Margin Line

To automatically draw a margin line, follow these steps:

1 Click . The Margin Line Tools are displayed on the toolbar.

2 Click .

Important: The Auto Margin Line feature can be used only with crowns. For cases involving inlays or onlays, you must manually draw the margin line.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 59

Page 66: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

3 Click on the preparation area. The tooth number selection arch diagram is displayed.

4 Select the corresponding tooth on the tooth number selection arch diagram.

5 Examine the margin line on the 3D model and do any of the following:

• To edit the margin line, click on the margin line to select it. Click . Redraw the

section of the margin line you want to alter, and be sure it connects with the existing margin line.

• To delete the margin line, select the margin line and click .

6 To view margin line references outside of the Acquisition interface, use the CS Mesh Viewer that was installed on your desktop.

60 Chapter 6 Acquiring a 3D Model for Restoration

Page 67: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Manually Drawing a Margin Line

You must manually draw the margin line if the case involves an inlay or onlay.

To manually draw a margin line, follow these steps:

1 Click . The Margin Line Tools are displayed on the toolbar.

2 Click . The tooth number selection arch diagram is displayed.

3 Select the corresponding tooth on the tooth number selection arch diagram.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 61

Page 68: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

4 Left-click and drag to draw the margin line around the preparation.

5 Examine the margin line on the 3D model and do any of the following:

• To edit the margin line, click on the margin line to select it. Click . Redraw the

section of the margin line you want to alter, and be sure it connects with the existing margin line.

• To delete the margin line, click on the margin line to select it. Click .

6 To view margin line references outside of the Acquisition interface, use the CS Mesh Viewer that was installed on your desktop.

62 Chapter 6 Acquiring a 3D Model for Restoration

Page 69: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Selecting 2D Images (Optional for CS 3600 Access)You can select 2D images from the 3D model to send to the dental lab along with the 3D model.

To select 2D images, follow these steps:

1 Click .

2 Manipulate the 3D model to the position you want to view.

3 Click on the areas of the 3D model for which you want 2D images. The images are displayed on the Views tab.

4 Click the checkmark on the upper-right corner of an image on the Views tab to move the image to the Saved Views tab.

5 When you are finished selecting 2D images, click to return to the Acquisition interface.

Note: The 2D image selection feature is available only during the acquisition step.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 63

Page 70: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Reviewing a Scan and Removing Unwanted Views Using Scan History CheckThe scan history check feature enables you to go backward and forward in a 3D model to check the scan. If you have areas of the scan containing mismatched or unwanted views, and you cannot remove

these areas using the tool, you can use the scan history check feature to return to the portion of

the scan just prior to where the mismatch occurred. Then you can re-scan the area.

To use the scan history check feature, follow these steps:

1 Click . The scan history check view is displayed.

2 Manipulate the 3D model to the position you want to view.

3 Click on the slider, and drag it to the left to remove portions of the scan. Moving the slider back to the right replaces the portions you removed.

64 Chapter 6 Acquiring a 3D Model for Restoration

Page 71: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

4 When you have removed the unwanted views from the scan, click OK to return to the Acquisition window.

5 To return to the Acquisition window without making any changes, click Cancel.

Note: Views removed using the scan history check feature cannot be restored.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 65

Page 72: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

66 Chapter 6 Acquiring a 3D Model for Restoration

Page 73: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

7 Acquiring a 3D Model for Orthodontics

You can use the CS 3600 to scan a full arch to create a 3D model. You then export this model to the CS Model software, where you can use the electronic model to take basic distance measurements, eliminating the need for taking impressions and working with or storing stone models. You should acquire images of the upper jaw, lower jaw, and the buccal bite registration. The software combines these images to create the 3D model.

To acquire a 3D model for orthodontic use, follow these procedures:

• Scan the upper and lower jaw.• Scan the buccal bite registration.• Refine the image.• Complete the preparation check and export the image.

Scanning Teeth on the Upper and Lower JawTo acquire images using auto acquisition, follow these steps:

1 Dry the teeth thoroughly before starting an acquisition.

2 Access the Acquisition interface by clicking in the imaging software.

3 Select in the Select Acquisition Type window, and click OK.

4 On the Acquisition interface, select the Upper Jaw acquisition mode.

OR

Note: In some cases, you can acquire images of a single arch (partial or full) and not obtain a buccal bite registration (for example, if there are no teeth in the opposing arch), but it is recommended that you acquire both arches and a buccal bite registration when possible.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 67

Page 74: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

On the CS 3600, press the mode button for one second to select the acquisition mode. The mode

indicator LED turns blue.

5 Hold the CS 3600 at a 90-degree angle to the occlusal surface of the teeth. Rest the tip on the tooth surface to steady the CS 3600. Live video is displayed on the video preview screen, and the acquisition begins. Images are automatically acquired and transferred to the 3D model display screen.

The image below shows several acquisitions of the upper jaw.

6 When the occlusal surface scan is complete, scan the lingual surface of the teeth. Hold the CS 3600 at a 45-degree angle to the lingual surface of the teeth. Be sure to include several millimeters of gingival tissue in the lingual scan.

Important: A green line with a red arrow indicates a weak connection among buccal, lingual, and occlusal surfaces that might cause an image stitching error, especially on incisor teeth. Scan the area until the arrows disappear.

68 Chapter 7 Acquiring a 3D Model for Orthodontics

Page 75: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

7 When the lingual surface scan is complete, scan the buccal surface of the teeth. Hold the CS 3600 at a 45-degree angle to the buccal surface of the teeth. Be sure to include several millimeters of gingival tissue in the buccal scan.

The example below shows a 3D model of the upper jaw when the occlusal, lingual, and buccal

surfaces have been completely scanned, as well as much of the palate.

8 Once the upper jaw has been scanned, you can begin scanning the lower jaw. Click and

repeat steps 5 through 7 until the teeth on the lower jaw are scanned.

Important: Re-dry the teeth as appropriate throughout the acquisition process.

Important: If holes are displayed in the scanned image, re-scan the area until the holes are filled. Use the mouse wheel to zoom in on the image for a closer look.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 69

Page 76: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

The example below shows a 3D model of the lower jaw when the occlusal, lingual, and buccal

surfaces have been completely scanned, including soft tissue.

9 Visually inspect the 3D model for any holes. If holes are present, re-scan the area until the holes are filled.

If you are not using the high resolution mode during acquisition, a green color on the 3D model

highlights existing holes in the image.

Re-scan the highlighted areas until the green is gone.

10 When you are satisfied with the 3D model, continue with the buccal bite registration acquisition.

70 Chapter 7 Acquiring a 3D Model for Orthodontics

Page 77: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Scanning the Buccal Bite RegistrationTo acquire a buccal bite registration using auto acquisition, follow these steps:

1 Click .

2 Have the patient bite down.

3 Position the CS 3600 at a 90-degree angle to the buccal surface of the teeth, and align the point where the upper and lower teeth meet in the middle of the video preview screen. Rest the tip on the tooth surface to help steady the CS 3600.

4 Move the CS 3600 slightly up and down to trigger the bite registration acquisition. If you have enabled the Capture Beep option in the Scanner Preferences window, a single beep indicates a successful capture.

The example below shows a buccal bite registration.

A dot is displayed at the bottom of the window to indicate the capture was successful. A

successful bite image includes both the upper and lower arch.

Once both arches are displayed in the Acquisition interface, the bite image is successful, and you

can acquire additional bite images, which will increase the accuracy of the bite.

Tip: After acquiring the buccal image of one jaw, always move toward the opposing arch with the CS 3600.

Important: For a full arch, you should acquire at least four buccal bite images—one on each side of the mouth at the molars, and one on each side of the mouth at the canines.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 71

Page 78: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

5 Acquire several additional buccal bite images. You can take up to six bite images for a full arch.

6 Once the bite has been registered, rotate the model and zoom the view to ensure that the bite is accurate and that there are no areas where the bite is mismatched. Click a dot to view the bite for that acquisition.

The example below shows several buccal bite registrations.

7 When you have finished acquiring the buccal bite registration, proceed to the orthodontic scan check—if you selected Enable Orthodontic Scan Check on the Advanced tab of the General Preferences window—or the check step.

72 Chapter 7 Acquiring a 3D Model for Orthodontics

Page 79: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Orthodontic Scan CheckThe orthodontic scan check step enables you to verify that all tooth surfaces are scanned correctly and ensure that sufficient soft tissue has been acquired.

To perform the orthodontic scan check, follow these steps:

1 Click . The Orthodontic Scan Check tab is displayed.

2 Click to scale the model to its best view. Examine the model to ensure that all tooth

surfaces and enough soft tissue have been acquired.

3 If you find holes in the image or if the image is missing information, click and re-scan the areas that are missing data.

4 When you have finished verifying that the model is complete, proceed to the check step.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 73

Page 80: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

CheckThe check step enables you to further process the 3D image to obtain the highest accuracy.

To refine the 3D model and further examine it, follow these steps:

1 Click to refine the image.

2 Manipulate the refined 3D model using the following methods:

• Right-click and hold on the 3D model to move it in the window.• Left-click and hold on the 3D model to rotate it.• If your mouse has a scroll wheel, use the wheel to zoom in or zoom out on the 3D model.

• Click to turn on the environment light.

• Click to scale the model to its best view.

Tip: When the light is on, a shadow appears, increasing the 3D effect and helping you to see the mesh. When the light is off, the shadow disappears, making the mesh brighter and helping you to see color and details.

Note: When using the CS 3600 Access, the Light button enables you to switch between monochromatic color and black/white HD 3D color.

74 Chapter 7 Acquiring a 3D Model for Orthodontics

Page 81: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click or to hide the upper or lower jaw. Click the button again to

restore the view of the jaw.

• Click to select and delete excess soft tissue in the image.

• Click to open the Quadrant Snapshot window, which displays multiple views of

the model.

• Right-click and hold on the center image to move it up and down or side to side.

• Click to export the five views as individual .JPG images to the patient’s

imaging folder. If you do not want to export a particular view, click the in the

upper right-hand corner of the image to deselect it.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 75

Page 82: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click to close the Quadrant Snapshot window.

• Click to view the occlusion pressure, displayed as a range of color on the mesh.

• Zoom in on the model to view a clear indication of how

occlusion is calculated in the model.

• Click to continue with the check process.

3 If you find holes in the image, click and re-scan the teeth that are missing data.

4 Repeat steps 1 through 3 until you are satisfied with the 3D model.

5 Click . The Preparation Check window is displayed.

76 Chapter 7 Acquiring a 3D Model for Orthodontics

Page 83: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

6 Examine the 3D model for holes and do one of the following:

• If there are no holes in the image, click the corresponding option in the Preparation Check window.

• If there are holes that need to be filled, click Cancel. Click and re-scan the

affected teeth.

7 Examine the 3D model for jagged boundaries and do one of the following:

• If there are no jagged boundaries in the image, click the corresponding option in the Preparation Check window.

• If you find jagged boundaries in the image, remove the boundaries using the tool.

8 Examine the 3D model for irregular soft tissue and do one of the following:

• If there is no irregular soft tissue in the image, click the corresponding option in the Preparation Check window.

• If you find irregular soft tissue, remove the irregular soft tissue using the tool.

9 When satisfied with the 3D model, click to send the 3D model to the imaging

software.

Important: To view your 3D models, use the CS Mesh Viewer that was installed on your desktop. For instructions on using the mesh viewer, click the ? button in the CS Mesh Viewer interface. If you are sending the DCM file to a lab, ask the lab to download the CS Mesh Viewer from the following link: http://sas-origin.onstreammedia.com/origin/carestreamhealthinc/CSMeshViewer/CSMeshViewer.zip

CS 3600 Family User and Installation Guide (9J8267)_Ed03 77

Page 84: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Selecting 2D Images (Optional for CS 3600 Access)You can select 2D images from the 3D model to send to the dental lab along with the 3D model.

To select 2D images, follow these steps:

1 Click .

2 Manipulate the 3D model to the position you want to view.

3 Click on the areas of the 3D model for which you want 2D images. The images are displayed on the Views tab.

4 Click the checkmark on the upper-right corner of an image on the Views tab to move the image to the Saved Views tab.

5 When you are finished selecting 2D images, click to return to the Acquisition interface.

Note: The 2D image selection feature is available only during the acquisition step.

78 Chapter 7 Acquiring a 3D Model for Orthodontics

Page 85: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Reviewing a Scan and Removing Unwanted Views Using Scan History CheckThe scan history check feature enables you to go backward and forward in a 3D model to check the scan. If you have areas of the scan containing mismatched or unwanted views, and you cannot remove

these areas using the tool, you can use the scan history check feature to return to the portion of

the scan just prior to where the mismatch occurred. Then you can re-scan the area.

To use the scan history check feature, follow these steps:

1 Click . The scan history check view is displayed.

2 Manipulate the 3D model to the position you want to view.

3 Click on the slider, and drag it to the left to remove portions of the scan. Moving the slider back to the right replaces the portions you removed.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 79

Page 86: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

4 When you have removed the unwanted views from the scan, click OK to return to the Acquisition window.

5 To return to the Acquisition window without making any changes, click Cancel.

Note: Views removed using the scan history check feature cannot be restored.

80 Chapter 7 Acquiring a 3D Model for Orthodontics

Page 87: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

8 Acquiring a 3D Model for Implants

You can use the scanner to acquire a full or partial arch containing an abutment or implant to create a 3D model. When you acquire a full or partial arch with an existing abutment, use the Standard Scan restoration acquisition workflow. When you acquire a full or partial arch containing an implant, use the Scan Body implant acquisition workflow. With the Scan Body implant acquisition workflow, the software replicates the image, enabling you to cut out the implant area, re-scan the jaw with the scan body in place, and create two 3D models—one containing the scan body, and one without. You then send these models to the lab that will create the custom abutment.

To acquire a 3D model for an implant, follow these procedures:

• Scan the upper and lower jaw.• Scan the buccal bite registration.• Use the cutting tools to cut out the implant area.• Install the scan body, and re-scan the jaw with the scan body.• Refine the image.• Complete the preparation check, and export the images.

Note: In some cases, you can acquire images of a single arch (partial or full) and not obtain a buccal bite registration (for example, if there are no teeth in the opposing arch), but it is recommended that you acquire both arches and a buccal bite registration when possible.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 81

Page 88: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Scanning Teeth on the Upper and Lower JawTo acquire images using auto acquisition, follow these steps:

1 Dry the teeth thoroughly before starting an acquisition.

2 Access the Acquisition interface by clicking in the imaging software.

3 Click in the Select Acquisition Type window, and click OK.

4 On the Acquisition interface, select the Upper Jaw acquisition mode.

OR

On the scanner, press the mode button for one second to select the acquisition mode. The mode

indicator LED turns blue.

5 Hold the scanner at a 90-degree angle to the occlusal surface of the implant area. Rest the tip on the tooth surface to steady the scanner. Live video is displayed on the video preview screen, and the acquisition begins. Images are automatically acquired and transferred to the 3D model display screen.

82 Chapter 8 Acquiring a 3D Model for Implants

Page 89: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

The image below shows several acquisitions of the upper jaw.

6 Slowly move the scanner tip along the occlusal surface to scan the remaining teeth in the implant area.

7 When the occlusal surface scan is complete, scan the lingual surface of the teeth in the implant area. Hold the scanner at a 45-degree angle to the lingual surface of the teeth.

8 When the lingual surface scan is complete, scan the buccal surface of the implant area. Hold the scanner at a 45-degree angle to the buccal surface of the teeth.

Important: Re-dry the teeth as appropriate throughout the acquisition process.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 83

Page 90: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

The example below shows a 3D model of the upper jaw when the occlusal, lingual, and buccal

surfaces have been completely scanned.

9 Once the upper jaw has been scanned:

You can continue with only the upper jaw, if desired. Click . A message is displayed,

stating that you have not acquired the opposing jaw and asking if you want to continue anyway.

Click Yes. Continue with the steps listed under “Using the Cutting Tools to Cut Out the Implant

Area” on page 88.

OR

You can begin scanning the lower jaw. Click and repeat steps 5 through 8 until the teeth

on the lower jaw are scanned.

Important: A green line with a red arrow indicates a weak connection among buccal, lingual, and occlusal surfaces that might cause an image stitching error, especially on incisor teeth. Scan the area until the arrows disappear.

Important: If holes are displayed in the scanned image on the implant area, re-scan the area until the holes are filled. Use the mouse wheel to zoom in on the implant area for a closer look.

Note: If you selected the Enable Refinement Check option in the Preferences window, the software will refine the image before you perform the cutting step.

84 Chapter 8 Acquiring a 3D Model for Implants

Page 91: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

The example below shows a 3D model of the lower jaw when the occlusal, lingual, and buccal

surfaces have been completely scanned.

10 Visually inspect the 3D model for any holes. If holes are present near the implant area, re-scan the area until the holes are filled.

If you are not using the high resolution mode during acquisition, a green color on the 3D model

highlights existing holes in the image.

Re-scan the highlighted areas until the green is gone.

11 When you are satisfied with the 3D model, continue with the buccal bite registration acquisition.

Important: If you acquire images of teeth from both the upper and lower jaw, you must also acquire the buccal bite registration.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 85

Page 92: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Scanning the Buccal Bite RegistrationTo acquire a buccal bite registration using auto acquisition, follow these steps:

1 Click .

2 Have the patient bite down.

3 Position the scanner at a 90-degree angle to the buccal surface of the implant area, and align the point where the upper and lower teeth meet in the middle of the video preview screen. Rest the tip on the tooth surface to help steady the scanner.

4 Move the scanner slightly up and down to trigger the bite registration acquisition. If you have enabled the Capture Beep option in the Scanner Preferences window, a single beep indicates a successful capture.

The example below shows a buccal bite registration.

A dot is displayed at the bottom of the window to indicate the capture was successful. A

successful bite image includes both the upper and lower arch.

Once both arches are displayed in the Acquisition interface, the bite image is successful, and you

can acquire additional bite images, which will increase the accuracy of the bite.

Tip: After acquiring the buccal image of one jaw, always move toward the opposing arch with the scanner.

Important: For a partial arch, you should acquire at least three buccal bite images—one on the preparation, one mesial to the preparation, and one distal to the preparation. For a full arch, you should acquire at least four buccal bite images—one on each side of the mouth at the molars, and one on each side of the mouth at the canines.

86 Chapter 8 Acquiring a 3D Model for Implants

Page 93: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

5 Acquire at least two more buccal bite images, one on either side of the implant area. You can take up to six bite images for a full arch.

6 Once the bite has been registered, rotate the model and zoom the view to ensure that the bite is accurate and that there are no areas where the bite is mismatched. Click a dot to view the bite for that acquisition.

The example shows several buccal bite registrations.

7 When you have finished acquiring the buccal bite registration, proceed with the process of cutting out the implant area using the Free Cut and Cut tools.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 87

Page 94: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Using the Cutting Tools to Cut Out the Implant AreaThe Free Cut and Cut tools enable you to remove the section of the image containing the implant so it can be replaced with the scan body image.

To cut the implant area from the 3D image, follow these steps:

1 Click .

Note: If you selected the Enable Refinement Check option in the Preferences window, the

software will refine the image before you perform the cutting step.

• If you are satisfied with the refined image, click and continue with the

cutting process.

• If you are not satisfied with the image, click and re-scan the area until the

holes are filled. Then click to proceed with the cutting process.

2 Do one of the following:

• Click . Click on the center of the implant area, and drag the mouse to draw a circle

big enough to surround the emergence profile and the scan body used.

Important: Be sure the circle is large enough to include the scan body diameter, or part of the scan body information may be lost after the image is refined.

88 Chapter 8 Acquiring a 3D Model for Implants

Page 95: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Release the mouse button.

OR

• Click . Click the mouse at several points around the implant to form a circle big

enough to surround the emergence profile and the scan body used.

Note: If you removed too much of the image, click to restore the image and repeat the cutting process.

Important: Be sure the circle is large enough to include the scan body diameter, or part of the scan body information may be lost after the image is refined.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 89

Page 96: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Double-click the mouse.

3 When you have finished cutting out the implant area, continue with the scan body acquisition.

Note: If you removed too much of the image, click to restore the image and repeat the cutting process.

90 Chapter 8 Acquiring a 3D Model for Implants

Page 97: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Acquiring the Scan Body on the Implant JawAfter you install the scan body, scan the jaw to incorporate the scan body into the 3D image. If there are several scan bodies on the jaw, see “Acquiring Multiple Scan Bodies on the Implant Jaw” on page 92.

To acquire an image of the jaw with the scan body in position, follow these steps:

1 Click .

2 Install the scan body.

3 Re-scan the jaw, concentrating on the area containing the scan body. Repeat the steps for acquiring an image as described in “Scanning Teeth on the Upper and Lower Jaw” on page 82.

4 When you have finished the scan body acquisition, proceed to the check step.

Note: If there is excessive soft tissue around a scan body, click to remove it

before proceeding to the next step.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 91

Page 98: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Acquiring Multiple Scan Bodies on the Implant Jaw

If there are multiple scan bodies on the jaw, use the Scan Body Area Selection tool to avoid a potential image mismatch. The Scan Body Area Selection tool enables you to select and scan only the area of the jaw where the scan body will be located, and the scanner will not add information to any other area. You can select only one scan body area at a time.

To acquire multiple scan bodies using the Scan Body Area Selection tool, follow these steps:

1 Click .

2 Click , and click the mouse on several points around the location of the scan body area to

form a circle.

3 Double-click the mouse. All areas of the jaw except the area you selected are highlighted in blue, and no additional information will be added to the blue areas, if scanned.

4 Install the first scan body, and scan the area containing the scan body.

5 Click to deselect the highlighted areas, and uninstall the first scan body.

6 Click , and click the mouse on several points around the location of the next scan body

area to form a circle.

7 Double-click the mouse.

8 Install the next scan body, and scan the area containing the scan body.

9 Click to deselect the highlighted areas, and uninstall the scan body.

10 Repeat the steps above for each remaining scan body.

11 When you have finished the scan body acquisition, proceed to the check step.

Note: If there is excessive soft tissue around a scan body, click to remove it

before proceeding to the next step.

92 Chapter 8 Acquiring a 3D Model for Implants

Page 99: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

CheckThe check step combines the implant image and the scan body image and enables you to further process the 3D image to obtain the highest accuracy.

To check the 3D model and further examine it, follow these steps:

1 Click to refine the image.

2 Manipulate both images in the split-screen view at the same time using the following methods:

• Right-click and hold on a 3D model to move both models in the window.• Left-click and hold on a 3D model to rotate both models.• If your mouse has a scroll wheel, use the wheel to zoom in or zoom out on the 3D models.

• Click to scale the models to their best view.

• Click or to leave the split-screen view, which enables you to modify the

3D model. Images in the split-screen view cannot be modified.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 93

Page 100: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click to turn on the environment light.

• Click or to view the image without the

scan body or with the scan body.

Tip: When the light is on, a shadow appears, increasing the 3D effect and helping you to see the mesh. When the light is off, the shadow disappears, making the mesh brighter and helping you to see color and details.

Note: When using the CS 3600 Access, the Light button enables you to switch between monochromatic color and black/white HD 3D color.

94 Chapter 8 Acquiring a 3D Model for Implants

Page 101: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

• Click to select and delete excess soft tissue in the image.

• Click to view the occlusion pressure, displayed as a range of color on the mesh.

• Zoom in on the model to view a clear indication of how

occlusion is calculated in the model.

• Click to continue with the check process.

3 If you find holes in the implant area, click and re-scan the teeth that are missing data.

4 Repeat steps 1 through 3 until you are satisfied with the 3D model.

5 Click . The arch diagram is displayed.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 95

Page 102: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

6 Click the Adult or Child icon to display the appropriate arch.

7 Select the teeth on the arch that were acquired for the 3D model, including those on the upper and lower jaw.

8 Click . The Preparation Check window is displayed.

9 Examine the scan body in the 3D model and do one of the following:

• If the entire scan body is visible, click the corresponding option in the Preparation Check window.

• If the entire scan body is not visible, click Cancel. Click and re-scan the

scan body.

10 Examine the bite on the 3D model and do one of the following:

• If the bite is acceptable, click the corresponding option in the Preparation Check window.

• If the bite is not acceptable, click Cancel. Click , make the necessary

adjustments to the implant area, and then re-scan the implant area and surrounding teeth.

11 Examine the gum tissue surrounding the implant in the 3D model and do one of the following:

• If all of the gum tissue is clearly visible, click the corresponding option in the Preparation Check window.

• If all of the gum tissue surrounding the implant is not visible, click Cancel. Click

and re-scan the affected tissue.

12 Examine the teeth adjacent to the implant in the 3D model and do one of the following:

• If the teeth are completely captured and there are no holes in the adjacent teeth, click the corresponding option in the Preparation Check window.

• If the teeth adjacent to the implant are missing or contain holes, click Cancel. Click

and re-scan the affected teeth.

96 Chapter 8 Acquiring a 3D Model for Implants

Page 103: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

13 When satisfied with the 3D model, click to send the 3D model to the imaging

software.

Selecting 2D Images (Optional for CS 3600 Access)You can select 2D images from the 3D model to send to the dental lab along with the 3D model.

To select 2D images, follow these steps:

1 Click .

2 Manipulate the 3D model to the position you want to view.

3 Click on the areas of the 3D model for which you want 2D images. The images are displayed on the Views tab.

4 Click the checkmark on the upper-right corner of an image on the Views tab to move the image to the Saved Views tab.

5 When you are finished selecting 2D images, click to return to the Acquisition interface.

Important: To view your 3D models, use the CS Mesh Viewer that was installed on your desktop. For instructions on using the mesh viewer, click the ? button in the CS Mesh Viewer interface. If you are sending the DCM file to a lab, ask the lab to download the CS Mesh Viewer from the following link: http://sas-origin.onstreammedia.com/origin/carestreamhealthinc/CSMeshViewer/CSMeshViewer.zip

Note: The 2D image selection feature is available only during the acquisition step.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 97

Page 104: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

Reviewing a Scan and Removing Unwanted Views Using Scan History CheckThe scan history check feature enables you to go backward and forward in a 3D model to check the scan. If you have areas of the scan containing mismatched or unwanted views, and you cannot remove

these areas using the tool, you can use the scan history check feature to return to the portion of

the scan just prior to where the mismatch occurred. Then you can re-scan the area.

To use the scan history check feature, follow these steps:

1 Click . The scan history check view is displayed.

2 Manipulate the 3D model to the position you want to view.

3 Click on the slider, and drag it to the left to remove portions of the scan. Moving the slider back to the right replaces the portions you removed.

98 Chapter 8 Acquiring a 3D Model for Implants

Page 105: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

4 When you have removed the unwanted views from the scan, click OK to return to the Acquisition window.

5 To return to the Acquisition window without making any changes, click Cancel.

Note: Views removed using the scan history check feature cannot be restored.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 99

Page 106: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

100Chapter 8 Acquiring a 3D Model for Implants

Page 107: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

9 Maintenance

Cleaning, Disinfecting, and SterilizingYou must clean, disinfect, and sterilize the scanner and accessories regularly.

The removable scanner tips can be autoclaved for up to 20 cycles. After 20 cycles, discard the tip. If you limit the holding time at 134°C to not more than 4 minutes, you can autoclave the tip up to 60 cycles. See the CS 3600 Family Safety, Regulatory, and Technical Specifications User Guide for more information.

Important: For information on cleaning, disinfecting, and sterilizing, see the CS 3600 Family Safety, Regulatory, and Technical Specifications User Guide.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 101

Page 108: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

102 Chapter 9 Maintenance

Page 109: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

10 Troubleshooting

CS 3600 Family Troubleshooting Instructions

Problem Description Action

Mismatching and overlap are visible in the 3D image.

Remove mismatched data and excessive tissue using the Free Cut tool or Scan History Check tool, and reacquire.

After bite registration, there is a gap or intersection between the upper jaw and the lower jaw.

Delete the bad bite view, and reacquire.

The margin line of the preparation is unclear.

Adjust the scanner position to see the margin line with good focus, then reacquire.

The scan body is missing after refinement.

Use the Free Cut or Cut tool to cut out the implant area before acquiring the scan body.

The acquired scan bodies are mismatched when there are multiple scan bodies side by side.

Use the Scan Body Area Selection tool. See “Acquiring Multiple Scan Bodies on the Implant Jaw” on page 92. Uninstall the neighboring scan bodies for better scanning of interproximal areas. Before refinement, remove excessive soft tissue overlapped with the scan bodies using the Free Cut tool or the Scan History Check tool.

Precision degradation is observed, or images are not well-stitched during acquisition.

Ensure that the lens window at the base of the scanner is clean by wiping it with a moist, lint-free cloth or lens tissue. Use a lens tissue or lint-free cloth to remove any dust or water stains from the mirror in the tip. Make sure the tip is firmly installed and there are no dark edges on the live video.

Reconstruction of metallic preparations is sometimes difficult.

Adjust the scanner position (for example: distance or angle) and scan more of the area. Adjust the operatory light away from the patient to decrease light scatter.

HD 3D color is not displayed after refinement, even though the Enable HD 3D option is selected in the Preferences window.

Go back to the Acquisition step, cut off any floating soft tissue, and make sure all of the teeth are scanned well.

The wait time for the anti-fog feature is increased after waking the scanner from sleep mode, removing it from the holder, or changing the tip.

Scan a complete arch without interruption, and limit the time that the scanner is exposed to the extraoral environment as much as possible, especially when the room temperature is low.

The tip is installed but not detected. No live video is displayed, and the No Tip icon is displayed at the bottom-right of the Acquisition window.

Reinstall the tip, and make sure the tip is in firm contact with the scanner.

The Overheating icon is displayed at the bottom-right of the Acquisition window, and the mode indicators and power button are blinking rapidly.

Place the scanner in the holder for 5 to 10 minutes. The scanner will become inactive and cool down.

CS 3600 Family User and Installation Guide (9J8267)_Ed03 103

Page 110: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

The mode indicators and the power button blink rapidly, but there is no Overheating icon displayed on the Acquisition window.

A component might be failing. Contact your local service provider for assistance.

Fogging appears on the inner surface of the lens window at the base of the scanner.

Mount a completely dry tip on the scanner, and place the scanner in the holder or set it on the desk, and wait until the fogging fades. If the fogging does not disappear completely after the scanner powers off (over 1 hour), contact your local service provider for assistance. Ensure that the tip is thoroughly dry before mounting on the scanner, and do not use a cloth soaked in disinfectant to clean the scanner.

Run the application on the dedicated graphics card is displayed after launching the Acquisition software.

1. Right-click on the desktop, and select NVIDIA Control Panel.

2. Under the 3D Settings options, click Manage 3D settings.

3. Click Program Settings.4. Under Select a program to customize, click Add, select

CS IO 3D Acquisition Interface from the list, and click Add Selected Program.

5. Under Select the preferred graphics processor for this program, select High-performance NVIDIA processor.

6. Click Apply.

Problem Description Action

104 Chapter 10 Troubleshooting

Page 111: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

11 Contact Information

Factory AddressRayco (Shanghai) Medical Products Company Limited1510 Chuanqiao Road, China (Shanghai) Pilot Free Trade ZoneShanghai, China 201206

Manufacturer’s Address

Authorized RepresentativesAuthorized Representative in the European Community

Carestream Health France 1, rue Galilée93192 Noisy-Le-Grand Cedex, France

Importer for European Union

Carestream Health Netherlands B.V.Bramenberg 123755 BZ EemnesThe Netherlands

Representante no Brasil Carestream do Brasil Comércio e Serviços de Produtos MédicosLtda.

Rua Pequetita, 215 cjs. 31 E 32 Edifício Atrium VII - Vila OlímpiaSão Paulo - BrazilCEP (Zip code): 04552-060

Carestream Health, Inc.150 Verona StreetRochester, NY USA 14608

EC REP

www.carestreamdental.com

CS 3600 Family User and Installation Guide (9J8267)_Ed03 105

Page 112: CS3600 User Gd Ed03 · CS 3600 Family User and Installation Guide (9J8267)_Ed03. 3. 2 . CS 3600 Family Overview. The CS 3600 Family comprises: • CS 3600 • CS 3600 Access . This

CarestA Division150 VeroRochesteUSA

User and Installation G

uide

©Carestrea

For morTo givewww.c

ream Dental of Carestream Health, Inc.

na St.r, NY 14608

e information, visit: www.carestreamdental.com documentation feedback, visit: arestreamdental.com/documentationfeedback

9J8267 Ed03 2017-09m Health, Inc., 2017.