  • Crown iDAS RF DesignMay 7th, 2015

  • Project Introduction

    1

  • Project Summary

    2

    This design is a 4 carrier, neutral host, active DAS system for the entire Baylor Grapevine Medical Center. The 3 sector system will provide 800 MHz, 850 MHz and 1900 MHz CDMA, WCDMA, EVDO (3G) coverage as well as 700MHz, 1900MHz and 2.1 GHz LTE (4G) coverage, to the Baylor Grapevine Medical Center patients, patrons and employees.

    Main coverage areas include the Lancaster Building, the Carter Building, the Box Building, the Professional Office Building, the Ambulatory Care Center, The new Patient Tower, and the Parking Garage all part of a connected office complex.

    The objective is to have ubiquitous, multi-carrier 3G and 4G wireless voice and data coverage, in all public and trafficked areas of the public areas, hospital wards, corridors and offices

  • Crown iDAS Design Parameters

    3

    Frequency BandTechnology (CDMA

    / UMTS / EVDO / GSM / LTE)

    # Channels% Pilot Power

    (CDMA/UMTS), Ref Signal Power (LTE)

    MIMO or SISO (LTE) / Channel BW

    # of Sectors

    Coverage Requirements Ec,

    RSRP, RSCP (dBm)

    ATT

    700 MHz LTE 1 SISO/10MHz TBD -85

    850 MHz UMTS 2 10% TBD -85

    1900 MHz UMTS 2 10% TBD -85

    2100 MHz LTE 1 SISO/10MHz TBD -85

    Verizon

    700 MHz LTE 1 SISO/10MHz TBD -85

    1900 MHz EVDO/CDMA 9 15% TBD -85

    2100 MHz LTE 1 SISO/10MHz TBD -85

    Sprint

    800 MHz CDMA 1X 1 10% TBD -85

    1900 MHz CDMA 1X 6 10% TBD -85

    1900 MHz LTE 1 SISO/5MHz TBD -85

    T-Mobile

    1900 MHz UMTS 2 8% TBD -85

    2100 MHz UMTS 2 8% TBD -85

    2100 MHz LTE 1 SISO/5MHz TBD -85

    Design Parameters Summary table includes all frequency bands, technologies, pilot powers and associated coverage requirements

  • System Overview

    4

    System Overview

    Network architecture includes:

    BTS connected by coax jumper to Andrew Intelligent Point of Interface (iPOI) DAS filter,

    connected by coax jumper cable to Andrew ION-B model TLCN8-W F splitter/combiner

    connected by coax jumper cable to Andrew ION-B model TLCN2-W 2 way RF splitter/combiner,

    connected by coax jumper cable to Andrew ION-B model TLCN8 splitter

    connected by coax jumper cable to Andrew ION-B model TFLN Fiber BDA Hub

    connected by Corning SST Optimizer Fiber Optic cable to Andrew ION-B model TFAH-US7B-34 Fiber BDA,

    connected by coax jumper cable to CSS Antenna model CCS CN-727 RF Coupler

    connected by coax jumper cable to Andrew model H-3-CPUSE-N-A Hybrid Coupler,

    connected by coax jumper cable to CSS Antenna model TRU-Omni S727 surface mounted indoor Omni-directional antenna

  • Design Assumptions

    5

    No on-site, site survey was conducted prior to design.

    New Patient Tower and Professional Office Building floor plans for floors 3, 4 and 5 did not include corridors or wall partitions, so designed was modeled accordingly.

    No macro network retune was assumed for design purposes.

    Hospital environment was considered:

    Additional coverage provided to Operating Room (OR) areas.

    X-ray, CT Scan, MRI and Nuclear/biological medicine areas shielded by lead to prevent RF interference to hospital systems.

    Existing electrical IDF closets were identified and utilized in the design wherever possible.

  • Design Disclaimers

    6

  • Sectorization Plan

    7

    Sectorization Plan:

    Baylor Regional Medical Center of Grapevine consists of a 7 building, 7 story office complex and 2 level Parking Garage. Total square footage = 115,932 Sq. Ft.

    Sector 1 includes: North and South Basements, Main Hospital 1st Floor and Parking Garage Levels 1 and 2

    Sector 2 includes: Hospital Floors 2 and 3

    Sector 3 includes: Hospital Floors 4, 5, and 6

  • Design Methodology

    8

    Design Methodology:

    Andrew ION-B family of iDAS components we chosen for cost effectiveness and flexibility in future expansion capability. The 7 story hospital campus was sectorized vertically as follows : Sector 1 covers the basement, floor 1 and floor 2 and parking garage level 1 and Sector 2 covers floor 3, floor 4, floor 5 and floor 6

    General objectives: Install DAS to offload existing macro network and ensure venue traffic is only served by dominant DAS carriers. Mitigating/minimizing any possible PIM related issues and provide PIM test capability.

    Capacity coverage is as much an objective as coverage capacity.

  • Equipment Summary

    9

    Equipment Summary:

    164 Omni Antenna

    81 Fiber BDA Remotes

    24 Fiber BDA Hubs

    27187 Ft. of Fiber Optic Cable

    8750 Ft. Coax Cable

  • Link Budget

    10

    Link Budget - Forward link budget for each technologyBaylor Grapevine Link Budget

    Band 700 LTE CELL PCS AWS 700 LTE PCS PCS AWS CDMA PCS PCS PCS AWS AWS

    Frequency 740 880 1930 2130 740 1930 1930 2130 860 1930 1930 1930 2130 2131

    Technology LTE UMTS UMTS LTE LTE EVDO CDMA LTE IDEN CDMA LTE UMTS UMTS LTE

    Equipment Family ION_B ION_B ION_B ION_B ION_B ION_B ION_B ION_B ION_B ION_B ION_B ION_B ION_B ION_B

    Maximum Composite Power 30.0 30.0 28.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 28.0 28.0 30.0

    Amplifier Sharing -3.0 -8.0 -6.0 -3.0 -8.0 -8.0 -6.0 -8.0 -8.0 -8.0 -6.0 -6.0

    # of Channels 1 2 2 1 1 3 6 1 1 6 1 2 2 1

    Power per Channel 27.0 27.0 17.0 24.0 27.0 17.2 14.2 24.0 30.0 14.2 22.0 17.0 19.0 24.0

    Pre-combining Losses

    Splitter Losses -6.5 -6.5 -6.5 -6.5 -6.5 -6.5 -6.5 -6.5 -6.5 -6.5 -6.5 -6.5 -6.5 -6.5

    Wireless Lan Module (MA860+ WCE) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

    1/2-inch Average Cable Length 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0

    1/2-inch Cable Loss -2.4 -2.7 -4.1 -4.5 -2.4 -4.1 -4.1 -4.5 -2.6 -4.1 -4.1 -4.1 -4.5 -4.5

    Antenna Gain (dBi) 2.9 2.9 6.4 7.3 2.9 6.4 6.4 7.3 2.9 6.4 6.4 6.4 7.3 7.3

    EIRP per antenna 21.0 20.7 12.8 20.3 21.0 13.0 10.0 20.3 23.8 10.0 17.8 12.8 15.3 20.3

    Coverage Distance (Radius) 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0

    Path Loss -55.1 -56.6 -63.4 -64.3 -55.1 -59.9 -59.9 -64.3 -52.9 -59.9 -59.9 -59.9 -60.8 -60.8

    Body Loss -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 -2.0 -2.0

    Wall/Clutter Loss -1.0 -1.0 -2.0 -2.0 -1.0 -2.0 -2.0 -2.0 -1.0 -2.0 -2.0 -2.0 -2.0 -2.0

    Fade Margin -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0

    Pilot margin (CDMA & WCDMA only) -10.0 -10.0 -8.2 -8.2 -10.0 -10.0 -11.0 -11.0

    RSSI Level -42.1 -53.9 -69.6 -53.0 -42.1 -64.1 -67.1 -53.0 -47.1 -68.9 -51.1 -67.1 -65.5 -49.5

    Ant Area Covered InBuilding 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000

    AT&T AT&T AT&T AT&T VZW VZW VZW VZW SPRINT SPRINT SPRINT T-MOBILE T-MOBILE T-MOBILE

  • Fiber Requirements

    11

    Fiber Requirements

    From Fiber to Remotes- Future proof for all tenants – 12 strands to each remote

    – From Head End to Demarcation Point– Verify that design meets Optical link budget

    – HAVE NOT BEEN ADDRESSED IN THIS PROPOSAL

  • Crown iDAS Channel Allocation

    12

    Channel Allocation

    Total 700 PS 700 LTE 800 SMR 800 PS 850 Cell 900 SMR 1900 PCS 2100 AWS

    AT&T01 10MHz 1x1

    SISO 02 UMTS 02 UMTS 01 10MHz 1x1 SISO

    Verizon01 10MHz 1x1

    SISO 03 EVDO, 06 CDMA 01 10MHz 1x1 SISO

    Sprint 01 CDMA 06 CDMA, 01 LTE

    T-Mobile 02 UMTS 02 UMTS, 01 LTE

  • Proprietary & Confidential

    Crown iDAS Design StandardsPower Allocation

    13

    Distribution of Power

    700 % Total Power Composite W Composite dBm Composite Available WSP dBm Channels Power per Channel dBm Pilot Power dBm

    AT&T LTE 50 1.0 30 25.23 1 27

    Verizon LTE 50 1.0 30 25.23 1 27

    800

    Sprint CDMA 100 1.0 30 30 1 27 -10

    850

    AT&T UMTS 100 1.0 30 30 2 27 -10

    1900

    AT&T UMTS 16.5 0.63 28 20.22 2 17 -10

    Verizon EVDO 16.5 1.0 30 20.97 3 17.2 -15

    Verizon CDMA 16.5 1.0 30 20.97 6 14.2 -15

    Sprint CDMA 16.5 1.0 30 20.97 1 14.2 -10

    Sprint LTE 16.5 1.0 30 20.97 1 22

    T-Mobile UMTS 16.5 0.63 28 20.22 2 17 -8

    2100

    AT&T LTE 25 0.25 30 22.19 1 24

    Verizon LTE 25 0.25 30 22.19 1 24

    T-Mobile LTE 25 0.25 30 22.19 1 24

    T-Mobile UMTS 25 0.63 28 18.97 2 19 -8

  • Cable Diagrams

    14

    Cable Diagrams on site drawings showing the interconnections and types of cables/fiber/coax between head end and intermediate distribution points, as well as between those points and the antennas

    Head end equipment Remote DAS equipment

    Equipment rack layout

  • Cable Diagrams

    15

    Cable Diagrams on site drawings showing the interconnections and types of cables/fiber/coax between head end and intermediate distribution points, as well as between those points and the antennasBaylor Grapevine Basement

    Proposed Headend location

    North Basement

    South Basement

  • Cable Diagrams

    16

    Cable Diagrams on site drawings showing the interconnections and types of cables/fiber/coax between head end and intermediate distribution points, as well as between those points and the antennasBaylor Grapevine 1st Floor

    Electrical rooms

    CT Scans

    X-ray/Radiology

    MRI Room

    Operating roomsOR

    CT

    MRI

    RAD

    NUC Nuclear/Bio med.

  • Cable Diagrams

    17

    Cable Diagrams on site drawings showing the interconnections and types of cables/fiber/coax between head end and intermediate distribution points, as well as between those points and the antennasBaylor Grapevine 2nd Floor

  • Cable Diagrams

    18

    Cable Diagrams on site drawings showing the interconnections and types of cables/fiber/coax between head end and intermediate distribution points, as well as between those points and the antennasBaylor Grapevine 3rd Floor

  • Cable Diagrams

    19

    Cable Diagrams on site drawings showing the interconnections and types of cables/fiber/coax between head end and intermediate distribution points, as well as between those points and the antennasBaylor Grapevine 4th Floor

  • Cable Diagrams

    20

    Cable Diagrams on site drawings showing the interconnections and types of cables/fiber/coax between head end and intermediate distribution points, as well as between those points and the antennasBaylor Grapevine 5th Floor

  • Cable Diagrams

    21

    Cable Diagrams on site drawings showing the interconnections and types of cables/fiber/coax between head end and intermediate distribution points, as well as between those points and the antennasBaylor Grapevine 6th Floor

    Note: Chases run from ground floor to 6th floor

  • Antenna and Remote Layout

    22

    Baylor Grapevine Basement

  • Antenna and Remote Layout

    23

    Baylor Grapevine 1st Floor

  • Antenna and Remote Layout

    24

    Baylor Grapevine 2nd Floor

  • Antenna and Remote Layout

    25

    Baylor Grapevine 3rd Floor

  • Antenna and Remote Layout

    26

    Baylor Grapevine 4th Floor

  • Antenna and Remote Layout

    27

    Baylor Grapevine 5th floor

  • Antenna and Remote Layout

    28

    Baylor Grapevine 6th Floor

  • Preliminary Head End Design

    29

  • Acceptance Test Criteria

    30

    Acceptance Test Criteria to be agreed upon including Coverage Targets:

    RSSI = > -85 dBm for 95% of venue

    LTE RSRP = > -85 dBm for 95% of venue

  • Specification Sheets

    31

    Specification Sheets for all antennas and equipment used in design

    Equipment Specs\CSS CN-727 coupler.pdf

    Equipment Specs\iPOI 850 UMTS.pdf

    Equipment Specs\TFAH-US7B-34 Remote.pdf

    Equipment Specs\H-3-CPUSE-N-A Hybrid coupler.pdf

    Equipment Specs\ion_b_series_TFLN.pdf

    Equipment Specs\iPOI 1700 AWS.pdf

    Equipment Specs\iPOI 800 LMR.pdf

    Equipment Specs\TRU-Omni S727 Antenna.pdf

    Equipment Specs\iPOI 850 UMTS.pdf

    Equipment Specs\iPOI 1900 LTE.pdf

    Equipment Specs\iPOI 700 LTE.pdf

    Equipment Specs\iPOI 1900 UMTS CDMA.pdf

    Equipment Specs\TLCN2_W

    Equipment Specs\TLCN8-W

    Equipment Spec\Corning SST Fiber

    Equipment Specs/CSS CN-727 coupler.pdfEquipment Specs/iPOI 850 UMTS.pdfEquipment Specs/TFAH-US7B-34 Remote.pdfEquipment Specs/H-3-CPUSE-N-A Hybrid coupler.pdfEquipment Specs/ion_b_series_TFLN.pdfEquipment Specs/iPOI 1700 AWS.pdfEquipment Specs/iPOI 800 LMR.pdfEquipment Specs/TRU-Omni S727 Antenna.pdfEquipment Specs/iPOI 850 UMTS.pdfEquipment Specs/iPOI 1900 LTE.pdfEquipment Specs/iPOI 700 LTE.pdfEquipment Specs/iPOI 1900 UMTS CDMA.pdfhttp://www.commscope.com/catalog/wireless/pdf/part/TLCN2-W.aspx?id=45983&ShowPatterns=Falsehttp://www.commscope.com/catalog/andrew/pdf/part/TLCN8-W.aspx?id=45988&ShowPatterns=Falsehttp://csmedia.corning.com/CableSystems/Resource_Documents/product_family_specifications_rl/EVO-654-EN.pdf

  • 3D Model View

    32

    View of 3D Model from iBwave

  • VZW 1900 CDMA Ec Showing worse case/weakest carrier coverage

    33

    Baylor Grapevine Sector 1 - Basement

  • VZW 1900 CDMA Ec 3D View

    34

    Baylor Grapevine Sector 1 - Basement

  • VZW 1900 CDMA Ec/Io

    35

    Baylor Grapevine Sector 1 - Basement

  • VZW 1900 CDMA Ec/Io 3D View

    36

    Baylor Grapevine Sector 1 - Basement

  • VZW 1900 CDMA Best Server

    37

    Baylor Grapevine Sector 1 – Basement

  • VZW 1900 CDMA Best Server 3D View

    38

    Baylor Grapevine Sector 1 - Basement

  • VZW 1900 CDMA Ec

    39

    Baylor Grapevine Sector 1 - 1st Floor and Parking Level 1

  • VZW 1900 CDMA Ec 3D View

    40

    Baylor Grapevine Sector 1 - 1st Floor and Parking Level 1

  • VZW 1900 CDMA Ec/Io

    41

    Baylor Grapevine Sector 1 - 1st Floor and Parking Level 1

  • VZW 1900 CDMA Ec/Io 3D View

    42

    Baylor Grapevine Sector 1 - 1st Floor and Parking Level 1

  • VZW 1900 CDMA Best Server

    43

    Baylor Grapevine Sector 1 - 1st Floor and Parking Level 1

  • VZW 1900 CDMA Best Server 3D view

    44

    Baylor Grapevine Sector 1 - 1st Floor and Parking Level 1

  • VZW 1900 CDMA Ec

    45

    Baylor Grapevine Sector 2 - 2nd Floor

  • VZW 1900 CDMA Ec 3D view

    46

    Baylor Grapevine Sector 2 - 2nd Floor

  • VZW 1900 CDMA Ec/Io

    47

    Baylor Grapevine Sector 2 - 2nd Floor

  • VZW 1900 CDMA Ec/Io 3D view

    48

    Baylor Grapevine Sector 2 - 2nd Floor

  • VZW 1900 CDMA Best Server

    49

    Baylor Grapevine Sector 2 - 2nd Floor

  • VZW 1900 CDMA Best Server 3D view

    50

    Baylor Grapevine Sector 2 - 2nd Floor

  • VZW 1900 CDMA Ec

    51

    Baylor Grapevine Sector 2 - 3rd Floor

  • VZW 1900 CDMA Ec 3D view

    52

    Baylor Grapevine Sector 2 - 3rd Floor

  • VZW 1900 CDMA Ec/Io

    53

    Baylor Grapevine Sector 2 - 3rd Floor

  • VZW 1900 CDMA SNIR 3D view

    54

    Baylor Grapevine Sector 2 - 3rd Floor

  • VZW 1900 CDMA Best Server

    55

    Baylor Grapevine Sector 2 - 3rd Floor

  • VZW 1900 CDMA Best Server 3D view

    56

    Baylor Grapevine Sector 2 - 3rd Floor

  • VZW 1900 CDMA Ec

    57

    Baylor Grapevine Sector 3 – 4th Floor

  • VZW 1900 CDMA Ec 3D view

    58

    Baylor Grapevine Sector 3 – 4th Floor

  • VZW 1900 CDMA Ec/io

    59

    Baylor Grapevine Sector 3 – 4th Floor

  • VZW 1900 CDMA SNIR 3D view

    60

    Baylor Grapevine Sector 3 – 4th Floor

  • VZW 1900 CDMA Best Server

    61

    Baylor Grapevine Sector 3 – 4th Floor

  • VZW 1900 CDMA Best Server 3D view

    62

    Baylor Grapevine Sector 3 – 4th Floor

  • VZW 1900 CDMA Ec

    63

    Baylor Grapevine Sector 3 – 5th Floor

  • VZW 1900 CDMA Ec 3D view

    64

    Baylor Grapevine Sector 2 – 5th Floor

  • VZW 1900 CDMA Ec/Io

    65

    Baylor Grapevine Sector 2 – 5th Floor

  • VZW 1900 CDMA SNIR 3D view

    66

    Baylor Grapevine Sector 2 – 5th Floor

  • VZW 1900 CDMA Best Server

    67

    Baylor Grapevine Sector 2 – 5th Floor

  • VZW 1900 CDMA Best Server 3D view

    68

    Baylor Grapevine Sector 2 – 5th Floor

  • VZW 1900 CDMA Ec

    69

    Baylor Grapevine Sector 2 – 6th Floor

  • VZW 1900 CDMA Ec 3D view

    70

    Baylor Grapevine Sector 2 – 5th Floor

  • VZW 1900 CDMA Ec/Io

    71

    Baylor Grapevine Sector 2 – 6th Floor

  • VZW 1900 CDMA Ec/Io 3D view

    72

    Baylor Grapevine Sector 2 – 6th Floor

  • VZW 1900 CDMA Best Server

    73

    Baylor Grapevine Sector 2 – 6th Floor

  • VZW 1900 CDMA Best Server 3D view

    74

    Baylor Grapevine Sector 2 – 6th Floor