Upload
danpy
View
30
Download
0
Tags:
Embed Size (px)
Citation preview
1
®
The information presented in this booklet is intended to reflect the most common diagrams
utilised by installers when commissioning a ST Runner system.
For assistance with wiring diagrams and programming your ST Runner system, please contact
your local agent or Housewatch direct on :-
Phone; 1300 472 472
Fax; 1300 672 672
ST RUNNER 4 TO 8 ALARM
DIAGRAM AND INSTALLATION MANUAL
Version 1.2
2
NOTE
NOTE if NOT using a sensor (PIR) in the
System, a 2.2k RESISTOR MUST be used across
the zones
If not using the 2.2k resistor in the system you
MUST change the programming All wiring diagrams are all with
a 2.2k resistor in them
3
INDEX
1. Wiring PIR’s ...................................................................... 4-9
2. Double Zone Wiring Diagram.......................................... 10,11
3. Installing Single Channel Receiver.................................. 12
4. Installing Four Channel Receiver.................................... 13
5. Setting Away and Stay modes with 4 Channel Receiver 14
6. Setting Areas A & B with 4 Channel Receiver .............. 15
7. Installing a Smoke Detector ............................................. 16,17
8. Wired Panic Alarm ...........................................................18
9. Installing Panic Alarm ......................................................18
10. Add, Change, Delete User Numbers................................ 19
11. Installing a Smoke Detector .............................................19
12. Setting Zones to Stay Mode .............................................. 20
13. Chime Zones Settings........................................................ 20
14. Entry & Exit Delay Times ................................................ 20
15. Mobile Phone Setup........................................................... 21,28
16. Dialler Reporting Options ................................................ 21,28
17. Monitoring Station Setup.................................................. 28,31
18. Crow Wave 8 Basic Setup Diagram................................. 32
4
SENSOR WIRING FOR 2 ZONES
INSTALLING 2 ZONES WITH 2.2K RESISTORS
Zone 1
SENSOR WIRING FOR 1 ZONE
INSTALLING 1 ZONE WITH 2.2K RESISTORS
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
2.2K RESISTORS
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
2.2K RESISTORS A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 1
Zone 2
5
SENSOR WIRING FOR 4 ZONES
INSTALLING 4 ZONES WITH 2.2K RESISTORS
SENSOR WIRING FOR 3 ZONES
INSTALLING 3 ZONES WITH 2.2K RESISTORS
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 2
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 3
2.2K RESISTORS
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 2
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 3
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 4
6
SENSOR WIRING FOR 5 ZONES
INSTALLING 5 ZONES WITH 2.2K RESISTORS
Zone 5
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 3
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 4
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
4.7k
8.2k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 2
PROGRAMMING ZONE 5 INTO SYSTEM
• Press Program button then installers number (000000) then Enter.
You are now in programming mode. The program light will be flashing.
• Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 5 on)
• Press Program then 125 then enter. Then press 1 then Enter. 3 will flash, press 14 then 14
will flash back then Enter (this changes the resistors).
7
SENSOR WIRING FOR 6 ZONES
INSTALLING 6 ZONES WITH 2.2K RESISTORS
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 2
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 3
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 4
4.7k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 5
8.2k
Zone 6
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
8.2k
4.7k
PROGRAMMING ZONE 5 & 6 INTO SYSTEM
• Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 5 on).
• Press Program then 122 then enter. Then press 6 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 6 on).
• Press Program then 125 then enter. Then press 1 then Enter. 3 will be lit up then press 14
then 14 will flash back then Enter (this changes the resistors).
• Press Program then 125 then enter. Then press 2 then Enter. 3 will be lit up then press 14
then 14 will flash back then Enter (this changes the resistors).
8
SENSOR WIRING FOR 7 ZONES
INSTALLING 7 ZONES WITH 2.2K RESISTORS
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 2
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 3
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 4
4.7k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 5
8.2k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 6
8.2k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 7
8.2k
4.7k 4.7k
PROGRAMMING ZONES 5, 6 & 7 INTO SYSTEM • Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 5 on).
• Press Program then 122 then enter. Then press 6 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 6 on).
• Press Program then 122 then enter. Then press 7 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 7 on).
• Press Program then 125 then enter. Then press 1 then Enter. 3 will be lit up then press 14
then 14 will flash back then Enter (this changes the resistors).
• Press Program then 125 then enter. Then press 2 then Enter. 3 will be lit up then press 14
then 14 will flash back then Enter (this changes the resistors).
• Press Program then 125 then enter. Then press 3 then Enter. 3 will be lit up then press 14
then 14 will flash back then Enter (this changes the resistors).
9
SENSOR WIRING FOR 8 ZONES
INSTALLING 8 ZONES WITH 2.2K RESISTORS
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 2
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 3
2.2K RESISTORS
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 4
4.7k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 5
8.2k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 6
8.2k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 7
8.2k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 8
8.2k
4.7k 4.7k
4.7k
PROGRAMMING ZONES 5, 6, 7 & 8 INTO SYSTEM • Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 5 on).
• Press Program then 122 then enter. Then press 6 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 6 on).
• Press Program then 122 then enter. Then press 7 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 7 on).
• Press Program then 122 then enter. Then press 8 then Enter. 7 will be lit up then press 1
then Enter (this turns zone 8 on).
• Press Program then 125 then enter. Then press 1 then Enter. 3 will be lit up then press 14
then 14 will flash back then Enter (this changes the resistors).
• Press Program then 125 then enter. Then press 2 then Enter. 3 will be lit up then press 14
then 14 will flash back then Enter (this changes the resistors).
• Press Program then 125 then enter. Then press 3 then Enter. 3 will be lit up then press 14
then 14 will flash back then Enter (this changes the resistors).
• Press Program then 125 then enter. Then press 4 then Enter. 3 will be lit up then press 14
then 14 will flash back then Enter (this changes the resistors).
10
Blue Wire
Blue Wire White Wire
White Wire
Join Wires
Inside panel
White Wire
Blue Wire Blue Wire White Wire
DOUBLE ZONE WIRING DIAGRAM
JOIN BLUE AND WHITE WIRE INSIDE THE PANEL
INSTALLING ZONES WITH 2.2K RESISTORS
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 1
4.7k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
Zone 5
8.2k 2.2k
11
DOUBLE ZONE WIRING DIAGRAM
JOIN BLUE AND WHITE WIRE INSIDE THE PANEL
DIFFERENT SENSOR WIRING AND REED SWITCH WIRING
INSTALLING ZONES WITH 2.2K RESISTORS
tam
per
12 V
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
GN
D
GN
D
12 V
2
1
Zone 1
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
4.7k
Zone 5
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
8.2k 2.2k
12 V
TA
MP
TA
MP
0 V
N/O
CO
M
Zone 1
4.7k
12 V
TA
MP
TA
MP
0 V
N/O
CO
M
Zone 1
4.7k
12 V
TA
MP
TA
MP
0 V
N/O
CO
M
Zone 5
8.2k 2.2k
12 V
TA
MP
TA
MP
0 V
N/O
CO
M
Zone 5
8.2k 2.2k
12 V
TA
MP
TA
MP
0 V
ALA
RM
Zone 5
8.2k
ALA
RM
12 V
TA
MP
TA
MP
0 V
ALA
RM
Zone 1
4.7k
ALA
RM
Zone 5
COM N/C N/O
COM N/C N/O
Zone 1
REED SWITCH WIRING
COM N/C N/O
Zone 1
4.7k
8.2k
2.2k
4.7k
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
8.2k
2.2k
Zone 5
12 VOLT SUPPLY
FROM BOARD
12
ADDING A TRANSMITTER (75-063) & SINGLE CHANNEL RECEIVER (75-067)
Enter into programming mode
Installer’s code (000000) set by default
• Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 111 then Enter. Then press 1 then Enter.
Press 1 so it lights up. Then Enter.
SETTING STROBE TO FLASH
(This will set the strobe to flash when the alarm is armed / disarmed)
• Press Program then 54 then Enter. Then press 1 then Enter.
Press 2 so it lights up. Then Enter.
• Press Program then 56 then Enter. Then press 1 then Enter.
Press 2 so it lights up. Then Enter.
• Press program then 39 then Enter. Then 2 then Enter. Then time in seconds
(ie 20 = 2 seconds) then Enter.
• Exit Program mode. Press Program then Enter.
SETTINGS FOR SINGLE CHANNEL RECEIVER 75-067
Set for one second
Cut LP 2
Don’t cut LP 1
4.7k resistor
75-067 Single
Channel Receiver
com
N/C
N/O
+ -
tam
per
12 V
Crow Alarm Panel
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
POS
NEG
CLK
DAT
LIN
GN
D
IN
AC
EARTH
GN
D
12 V
2
1
Alarm panel
Tamper switch
Normally closed
2.2k resistor
Already
In system
13
ADDING A TRANSMITTER (75-063) & 4 CHANNEL RECEIVER (75-064)
Enter into programming mode
Installer’s code (000000) set by default
• Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 111 then Enter. Then press 1 then Enter.
Press 1 so it lights up. Then Enter.
SETTING STROBE TO FLASH
• Press Program then 54 then Enter. Then press 1 then Enter.
Press 2 so it lights up. Then Enter.
• Press Program then 56 then Enter. Then press 1 then Enter.
Press 2 so it lights up. Then Enter.
• Press program then 39 then Enter. Then 2 then Enter. then time in seconds
(ie 20 = 2 seconds) then Enter.
• Exit Program mode. Press Program then Enter.
4.7k resistor
75-064
4 CHANNEL
RECEIVER
CH 1 CH 2 CH 3 CH 4 12v
Pwr In
CO
M
CO
M
CO
M
CO
M
N/C
N/C
N/C
N/C
N/O
N/O
N/O
N/O
+ –
tam
per
12 V
Crow Alarm Panel
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
POS
NEG
CLK
DAT
LIN
GN
D
IN
AC
EARTH
GN
D
12 V
2
1
Alarm panel
Tamper switch
Normally closed
2.2k resistor
Already
In system
14
2.2k resistor
Already
In system
AWAY (ARM / DISARM) AND STAY MODE
USING TRANSMITTER & 4 CHANNEL RECEIVER (75-064)
Enter into programming mode
Installer’s code (000000) set by default
• Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 111 then Enter. Then press 1 then Enter.
Press 1 so it lights up. Then Enter.
• Press Program then 111 then Enter. Then press 2 then Enter.
Press 1 so it lights up. Then Enter.
• Press Program then 112 then Enter. Then press 2 then Enter.
Press 1,3 so the lights go off and then press 2,4 so they light up. Then Enter.
SETTING STROBE TO FLASH
• Press Program then 54 then Enter. Then press 1 then Enter.
Press 2 so it lights up. Then Enter.
• Press Program then 56 then Enter. Then press 1 then Enter.
Press 2 so it lights up. Then Enter.
• Press program then 39 then Enter. Then 2 then Enter. then time in sec then Enter
• Exit Program mode. Press Program then Enter.
4.7k resistor
75-064
4 CHANNEL
RECEIVER
CH 1 CH 2 CH 3 CH 4 12v
Pwr In
CO
M
CO
M
CO
M
CO
M
N/C
N/C
N/C
N/C
N/O
N/O
N/O
N/O
+ –
tam
per
12 V
Crow Alarm Panel
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
POS
NEG
CLK
DAT
LIN
GN
D
IN
AC
EARTH
GN
D
12 V
2
1
Alarm panel
Tamper switch
Normally closed
8.2k resistor
15
AREAS A and B
USING TRANSMITTER & 4 CHANNEL RECEIVER (75-064)
Enter into programming mode
Installer’s code (000000) set by default
• Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 111 then Enter. Then press 1 then Enter.
Press 1 so it lights up. Then Enter.
• Press Program then 111 then Enter. Then press 2 then Enter.
Press 2 so it lights up. Then Enter.
.
SETTING STROBE TO FLASH
• Press Program then 54 then Enter. Then press 1 then Enter.
Press 2 so it lights up. Then Enter.
• Press Program then 56 then Enter. Then press 1 then Enter.
Press 2 so it lights up. Then Enter.
• Press program then 39 then Enter. Then 2 then Enter. then time in sec then Enter
• Exit Program mode. Press Program then Enter.
4.7k resistor
75-064
4 CHANNEL
RECEIVER
CH 1 CH 2 CH 3 CH 4 12v
Pwr In
CO
M
CO
M
CO
M
CO
M
N/C
N/C
N/C
N/C
N/O
N/O
N/O
N/O
+ –
tam
per
12 V
Crow Alarm Panel
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
POS
NEG
CLK
DAT
LIN
GN
D
IN
AC
EARTH
GN
D
12 V
2
1
Alarm panel
Tamper switch
Normally closed
8.2k resistor
2.2k resistor
Already
In system
16
ADDING SMOKE DETECTOR TO ZONE
Enter into programming mode
Installer’s code (000000) set by default • Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 122 then Enter.
Select the zone you wish to use, As Normally open. Then Enter.
• 1,6,7 will be lit up. press 6,7,2 No 2 will light up and 6,7 will go out. Then Enter.
• Press Program then 123 then Enter.
Select the same number zone as above. (The zone you made normally open )
Then Enter. Press number 5 then enter.
This will set zone as fire zone.
• Exit Program mode. Press Program then Enter.
2.2k resistor tam
per
Crow Alarm Panel
12 V
O V
Set up for zone 2 When Zones 5 to 8 not used
2.2k resistor
12 V
O V
Set up for zone 4 When Zones 5 to 8 not used
Latching smoke detector
Normally open
Latching smoke detector
Normally open
Address Program 122, location zone 4,select No 2. Enter
Address Program 123, location zone 4,Select No 5. Enter
Diagram 2
Address Program 122, location zone 2,select No 2. Enter
Address Program 123, location zone 2,Select No 5. Enter
tam
per
12 V
Crow Alarm Panel
Diagram 1
GN
D
4
C
2
3
C
1
2
C
1
4
C
3
12 V
GN
D
ZONE 4
ZONE 2
17
8.2k resistor
tam
per
12 V
Crow Alarm Panel
12 V
O V
Set up for zone 8 When Zones are being doubled
Latching smoke detector
Normally open
Address Program 122, location zone 8,select No’s 1 & 2. Enter
Address Program 123, location zone 8,Select No 5. Enter
Address Program 125, location zone 4,Select No 14. Enter
Diagram 1
GN
D
4
C
2
3
C
1
2.2k resistor
ADDING SMOKE DETECTOR TO ZONE
WHEN USING MORE THAN EIGHT ZONES
Enter into programming mode
Installer’s code (000000) set by default • Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 122 then Enter. Press 8 then Enter. 7 Will be lit up. Press 7,2,1
numbers 2 and 1 will light up and 7 will go out. Then Enter
Zones1 to 4 need a 4.7 resistor across the contacts.
Zones 5 to 8 need a 8.2k resistor across the contacts.
As per Diagram 1
• Press Program then 123 then Enter. Press 8 then Enter. Press 5 so it lights up then Enter.
This will set zone as fire zone.
• Press Program then 125 then enter. Then press 4 then Enter. 3 will flash then press 14 then
14 will flash back then Enter.
• Exit Program mode. Press Program then Enter.
ZONE 8
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
4.7k
18
4.7k resistor
ADDING PANIC BUTTON TO ZONE
Enter into programming mode
Installer’s code (000000) set by default • Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
• Press Program then 122 then Enter.
Select the zone you wish to use, As Normally open. Then Enter.
• Numbers 1,6,7 will be lit up. Press 6,7,2 number 2 will light up and 6,7 will go out.
Then Enter. Zones1 to 8 need a 2.2k resistor across the contacts.
• Press Program then 123 then Enter.
Select the same number zone as above. Then Enter
Press 3 then Enter. This will set zone as 24 hour zone.
• Exit Program mode. Press Program then Enter.
As per Diagram 1
Set up for zone 4
Set up for zone 8 When Zones 4 is being used
as a zone
2.2k resistor
Panic Button
Normally
open
8.2k resistor
Panic Button
Normally
open
Address Program 122, location zone 4
select No 2 & 6 & 7 . 2 will light up 7 &
6 will go out then Enter.
Address Program 123, location zone 4
Select No 3 then Enter
tam
per
12 V
Crow Alarm Panel
Diagram 1
GN
D
4
O V
2
3
O V
1
tam
per
12 V
Crow Alarm Panel
Diagram 2
GN
D
4
O V
2
3
O V
1
Address Program 122, location zone 8
select No1 & 2 then Enter
Address Program 123, location zone 8
Select No 3 then Enter
Address Program 125, location zone
4,select No 14. Enter
Zone 8
ZONE 4
A B
C
D E F
12 V
TAMP TAMP
0 V
ALARM
ALARM
Zone 4
2.2k resistor
19
PIN NUMBER CHANGING
ADD / CHANGE / DELETE USER NUMBERS
There is a Maximum 100 Users
Enter into programming mode
Installer’s code (000000) set by default • Press Program button then installers number (000000) then Enter.
You are now in programming mode. Program light will be flashing.
User 1
• Press Program then 1 then Enter, Then 1 then Enter. Then user number
(1 to 6 Digits in Length) then Enter. ( 123 is default )
User 1 is Master Code which can be used to change Codes, Clock, and Phone No’s
User 2
Press Program then 1 then Enter. Then 2 then Enter. Then user number
(1 to 6 Digits) then Enter.
User 3
Press Program then 1 then Enter. Then 3 then Enter. Then user number
(1 to 6 Digits) then Enter.
Users 4 to 100 can be added by following the steps above
CHANGE INSTALLERS NUMBER
Press Program then 25 then Enter. Then 1 then Enter.
Enter installer number (3 to 6 digits in Length) then Enter. (000000) default.
Delete User Number (LED KEYPAD)
Press Program then the user number location you want to delete (2 to 100) then Enter, then By-
pass then Enter.
Delete User Number (LCD KEYPAD)
Press Program then 1 Then Enter. Then the user number location you want to delete (2 to 100)
then Enter, then Control then 0 then Enter.
Defaulting System
Press Program then 200 then Enter. Then 10 then Enter.
Defaulting System numbers
Press Program then 200 then Enter. Then 9 then Enter. ( pin numbers & phone numbers)
ADDRESS USER No NUMBER
USER 1 1 1 123
USER 2 1 2
USER 3 1 3
USER 4 1 4
USER 5 1 5
USER 6 1 6
USER 7 1 7
USER 8 1 8
USER 9 1 9
User codes can be between
1 and 6 digits in length
Default
20
SETTING THE CLOCK
Press Program then 26 then Enter then 1 then Enter then the time (24 hour time)
then Enter.
Press Program then 26 then Enter then 2 then Enter. Then the day
1=Sun, 2=Mon, 3=Tue, 4=Wed, 5=Thu, 6=Fri, 7=Sat, then Enter.
Press Program then 26 then Enter then 3 then Enter. Then the date (day / month / year)
DD/MM/YY
ENTRY & EXIT DELAY TIMES
Zone 1 is Set to entry and exit ( Default setting 20 seconds entry / 60 seconds exit.)
Change Entry Times ( Zone 1)
Press program then 144 then Enter. Then 1 then Enter. Then the time in seconds
(0-9999) then Enter.
Change Entry Times ( Zone 2)
Press program then 144 then Enter. Then 2 then Enter. Then the time in seconds
(0-9999) then Enter.
Change Entry Times ( Zone 3)
Press program then 144 then Enter. Then 3 then Enter. Then the time in seconds
(0-9999) then Enter.
To change any other zone entry time, follow steps above
Zones 2 to 8 Are Set To 0 Seconds for instance.
Change Exit Times Press Program then 60 then Enter. then 1 then Enter then the time in seconds
(0-255) then Enter.
Default Set for 60 Seconds
EXTRA SETTINGS
Setting Zones For Stay Mode
(1 to 4 are on by default)
Press Program then 122 then Enter. Then Press the zones you want in stay mode
(4 To 8) then Enter. Then press number 6 so it lights up then press Enter.
Setting Zones To Chime Zone (Disarmed) Press Program then 123 then Enter, Then press the zones to be chime zones then Enter.
Then press 7 so it lights up then Enter.
Wired Panic Alarm
Press Program then 122 then Enter. Then press the zone number you are using for this
type of alarm then Enter 1,6,7 will be light up press 6,7,2 number will light up 6,7 will
go out then Enter.
Press Program then 123 then Enter. Then press the zone number you are using for this
alarm then Enter press 3 then Enter. (this will set for 24 hour zone).
Exit programming mode. Press Program then Enter.
21
MOBILE PHONE SETUP
Turn Dialler On
Press Program then 175 then Enter, Then press 1 then Enter. numbers 2,6,7, should be lit up,
Press 7 so it goes out. Press 1 so it lights up Then press Enter (Turns on dialler).
Press Program then 175 then Enter, Then press 5 then Enter. 168 will flash.
Press 0 then Enter.
( NOTE : The settings below will allow the alarm to call your mobile once and if not answered to move on to next
stored number )
FIRST PHONE NUMBER
Entering Phone Numbers
First Number
Press Program then 181 then Enter. Then Enter 1 Then Enter. Then press Phone Number (Up
to 16 Digits) then Enter.
Press Program then 182 then Enter. Then press 1 then Enter. 1will flash on .Then press 2 then
Enter.
Press Program then 183 then Enter. Then press 1 then Enter. 1,2,4 will be light up Then press ,4
then Enter.(1,2, will light up and 4, will go out)
Press Program then 184 then Enter. Then press 1 then Enter, 3 will flash . Press 1
and then press Enter
Press Program then 186 then Enter. Then press 1 then Enter,
1 = Report Mains Fail (Turn Off)
2 = Report Low Battery (Turn Off)
3 = Report Radio battery low (Turn Off)
4 = Report Line Failure (Turn Off)
5 = Report System Tamper (Leave On)
6 = Report keypad Tamper (Turn Off)
7 = Report Zone Tamper (Turn Off)
8 = Report Radio Tamper (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Note: You Can Not Turn Off The Alarm Activity Reporting.
Press Program then 187 then Enter. Then press 1 then Enter,
1 = Report Duress Alarm (Turn Off)
2 = Report Radio Alarm (Turn Off)
3 = Report Sensor Watch (Turn Off)
4 = Report Panic Alarm (Turn Off)
5 = Report Fire Alarm (Leave On)
6 = Report Medical Alarm (Turn Off)
7 = Report Pendant Alarm (Turn Off)
8 = Report Zone Bypasses (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter
22
FIRST PHONE NUMBER
CONTINUED
Press Program then 188 then Enter. Then 1 then Enter
1 = Report Arm/Disarm (Turn Off)
2 = Report Stay mode arm (Turn Off)
3 = Report Disarm activation (Turn Off)
4 = Report Stay activation (Turn Off)
5 = Report Stay mode (Turn Off)
6 = Report Program mode (Leave Off)
7 = Report 24 hours (Leave On)
8 = Report restores (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Note: You Can Not Turn Off The Alarm Activity Reporting.
Press Program then 189 then Enter. Then press 1 then Enter,
1 = Report latchkey (Leave Off)
2 = Report delinquent (Leave Off)
3 = Report tests (Turn Off)
4 = Report fuse failure (Turn Off)
5 = Report output fail (Turn Off)
6 = Report time change (Leave Off)
7 = Report keypad trouble (Leave Off)
8 = Report Zone rf jamming (Leave Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter
MOBILE PHONE SETUP
23
SECOND PHONE NUMBER
Entering Phone Numbers
Second Number
Press Program then 181 then Enter. Then Enter 2 Then Enter. Then press Phone Number (Up
to 16 Digits) then Enter.
Press Program then 182 then Enter. Then press 2 then Enter. 1 will flash on .Then press 2 then
Enter.
Press Program then 183 then Enter. Then press 2 then Enter. 1,2,4 will be lit up Then press 4
then Enter. (1,2, will light up and 4, will go out).
Press Program then 184 then Enter. Then press 2 then Enter, 3 will flash . Press 1
and then press Enter.
Press Program then 186 then Enter. Then press 2 then Enter.
1 = Report Mains Fail (Turn Off)
2 = Report Low Battery (Turn Off)
3 = Report Radio battery low (Turn Off)
4 = Report Line Failure (Turn Off)
5 = Report System Tamper (Leave On)
6 = Report keypad Tamper (Turn Off)
7 = Report Zone Tamper (Turn Off)
8 = Report Radio Tamper (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Note: You Can Not Turn Off The Alarm Activity Reporting.
Press Program then 187 then Enter. Then press 2 then Enter,
1 = Report Duress Alarm (Turn Off)
2 = Report Radio Alarm (Turn Off)
3 = Report Sensor Watch (Turn Off)
4 = Report Panic Alarm (Turn Off)
5 = Report Fire Alarm (Leave On)
6 = Report Medical Alarm (Turn Off)
7 = Report Pendant Alarm (Turn Off)
8 = Report Zone Bypasses (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter
MOBILE PHONE SETUP MOBILE PHONE SETUP
24
SECOND PHONE NUMBER
CONTINUED
Press Program then 188 then Enter. Then 2 then Enter
1 = Report Arm/Disarm (Turn Off)
2 = Report Stay mode arm (Turn Off)
3 = Report Disarm activation (Turn Off)
4 = Report Stay activation (Turn Off)
5 = Report Stay mode (Turn Off)
6 = Report Program mode (Leave Off)
7 = Report 24 hours (Leave On)
8 = Report restores (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Note: You Can Not Turn Off The Alarm Activity Reporting.
Press Program then 189 then Enter. Then press 2 then Enter.
1 = Report latchkey (Leave Off)
2 = Report delinquent (Leave Off)
3 = Report tests (Turn Off)
4 = Report fuse failure (Turn Off)
5 = Report output fail (Turn Off)
6 = Report time change (Leave Off)
7 = Report keypad trouble (Leave Off)
8 = Report Zone jamming (Leave Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter
MOBILE PHONE SETUP
25
THIRD PHONE NUMBER
Entering Phone Numbers
Third Number
Press Program then 181 then Enter. Then Enter 3 Then Enter. Then press Phone Number (Up
to 16 Digits) then Enter.
Press Program then 182 then Enter. Then press 3 then Enter. 1will flash on .Then press 2 then
Enter.
Press Program then 183 then Enter. Then press 3 then Enter. 1,2,4 will be lit up Then press 4
then Enter. (1,2, will light up and 4, will go out).
Press Program then 184 then Enter. Then press 3 then Enter, 3 will flash . Press 1
and then press Enter.
Press Program then 186 then Enter. Then press 3 then Enter,
1 = Report Mains Fail (Turn Off)
2 = Report Low Battery (Turn Off)
3 = Report Radio battery low (Turn Off)
4 = Report Line Failure (Turn Off)
5 = Report System Tamper (Leave On)
6 = Report keypad Tamper (Turn Off)
7 = Report Zone Tamper (Turn Off)
8 = Report Radio Tamper (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Note: You Can Not Turn Off The Alarm Activity Reporting.
Press Program then 187 then Enter. Then press 3 then Enter,
1 = Report Duress Alarm (Turn Off)
2 = Report Radio Alarm (Turn Off)
3 = Report Sensor Watch (Turn Off)
4 = Report Panic Alarm (Turn Off)
5 = Report Fire Alarm (Leave On)
6 = Report Medical Alarm (Turn Off)
7 = Report Pendant Alarm (Turn Off)
8 = Report Zone Bypasses (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter
MOBILE PHONE SETUP
26
THIRD PHONE NUMBER
CONTINUED
Press Program then 188 then Enter. Then 3 then Enter
1 = Report Arm/Disarm (Turn Off)
2 = Report Stay mode arm (Turn Off)
3 = Report Disarm activation (Turn Off)
4 = Report Stay activation (Turn Off)
5 = Report Stay mode (Turn Off)
6 = Report Program mode (Leave Off)
7 = Report 24 hours (Leave On)
8 = Report restores (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Note: You Can Not Turn Off The Alarm Activity Reporting.
Press Program then 189 then Enter. Then press 3 then Enter,
1 = Report latchkey (Leave Off)
2 = Report delinquent (Leave Off)
3 = Report tests (Turn Off)
4 = Report fuse failure (Turn Off)
5 = Report output fail (Turn Off)
6 = Report time change (Leave Off)
7 = Report keypad trouble (Leave Off)
8 = Report Zone jamming (Leave Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter
MOBILE PHONE SETUP
27
FOURTH PHONE NUMBER
Entering Phone Numbers
Fourth Number
Press Program then 181 then Enter. Then Enter 4 Then Enter. Then press Phone Number (Up
to 16 Digits) then Enter.
Press Program then 182 then Enter. Then press 4 then Enter. 1will flash on .Then press 2 then
Enter.
Press Program then 183 then Enter. Then press 4 then Enter. 1,2,4 will be lit up Then press 4
then Enter. (1,2, will light up and 4, will go out).
Press Program then 184 then Enter. Then press 4 then Enter, 3 will flash . Press 1
and then press Enter.
Press Program then 186 then Enter. Then press 4 then Enter.
1 = Report Mains Fail (Turn Off)
2 = Report Low Battery (Turn Off)
3 = Report Radio battery low (Turn Off)
4 = Report Line Failure (Turn Off)
5 = Report System Tamper (Leave On)
6 = Report keypad Tamper (Turn Off)
7 = Report Zone Tamper (Turn Off)
8 = Report Radio Tamper (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Note: You Can Not Turn Off The Alarm Activity Reporting.
Press Program then 187 then Enter. Then press 4 then Enter.
1 = Report Duress Alarm (Turn Off)
2 = Report Radio Alarm (Turn Off)
3 = Report Sensor Watch (Turn Off)
4 = Report Panic Alarm (Turn Off)
5 = Report Fire Alarm (Leave On)
6 = Report Medical Alarm (Turn Off)
7 = Report Pendant Alarm (Turn Off)
8 = Report Zone Bypasses (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
MOBILE PHONE SETUP
28
FOURTH PHONE NUMBER
CONTINUED
Press Program then 188 then Enter. Then 4 then Enter
1 = Report Arm/Disarm (Turn Off)
2 = Report Stay mode arm (Turn Off)
3 = Report Disarm activation (Turn Off)
4 = Report Stay activation (Turn Off)
5 = Report Stay mode (Turn Off)
6 = Report Program mode (Leave Off)
7 = Report 24 hours (Leave On)
8 = Report restores (Turn Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Note: You Can Not Turn Off The Alarm Activity Reporting.
Press Program then 189 then Enter. Then press 4 then Enter,
1 = Report latchkey (Leave Off)
2 = Report delinquent (Leave Off)
3 = Report tests (Turn Off)
4 = Report fuse failure (Turn Off)
5 = Report output fail (Turn Off)
6 = Report time change (Leave Off)
7 = Report keypad trouble (Leave Off)
8 = Report Zone rf jamming (Leave Off)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter
MOBILE PHONE SETUP
29
MONITORING STATION SET UP
Press Program then 175 then Enter, Then press 1 then Enter. Numbers 2,6,7, are lit up.
Press 1 so it lights up. Then press Enter (Turns on dialler).
Test call time of the day: Press Program then 175 then Enter, Then press 4 then Enter.
Enter the time of the day to send the call in 24 hour time HH.MM
(0430 the time is set by default).
Test call day times: Press Program then 175 then Enter, Then press 5 then Enter. 1,6,8 will flash .
Press 24 (every24 hours it will send a test call) Then Enter.
(168 set by default: once a week)
Monitoring account code: Press Program then 62 then Enter. Then press 1 then Enter.
Then Enter the account number then Enter. (Account number from the monitoring company).
Entering Phone Numbers
Primary Number
Press Program then 181 then Enter. Then Enter 1 Then Enter. Then press Phone Number
(Up to 16 Digits) then Enter.
Press Program then 184 then Enter. Then press 1 then Enter, Number 3 will flash . Then Press 6
then press Enter.
Check with monitoring company on what they want on
Press Program then 186 then Enter. Then 1 then Enter.
1 = Report Mains Failure (Leave On)
2 = Report Low battery (Leave On)
3 = Report Wireless Battery (Leave On)
4 = Report Line Failure (Leave On)
5 = Report System Tamper (Leave On)
6 = Report Key pad Tam (Leave On)
7 = Report Zone Tamper (Leave On)
8 = Report Radio Tamper (Leave On)
Press Program then 187 then Enter. Then 1 then Enter.
1 = Report Duress Alarm (Leave On)
2 = Report Radio (Leave On)
3 = Report Sensor watch (Leave On)
4 = Report panic (Leave On)
5 = Report Fire (Leave On)
6 = Report Medical (Leave On)
7 = Report Radio Panic (Leave On)
8 = Zone bypasses (Leave On)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
30
MONITORING STATION SET UP CONTINUED
Press Program then 188 then Enter. Then 1 then Enter
1 = Report Open / Close (Turn Off)
2 = Report Stay Open / Close (Turn Off)
3 = Report Open after Alarm (Turn Off)
4 = Report Stay Open after Alarm (Turn Off)
5 = Report Alarm in Stay (Turn Off)
6 = Report Access programming (Leave Off)
7 = Report 24 hr alarm (leave On)
8 = Report Restores (Leave On)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Press Program then 189 then Enter.
1 = Report latch (Turn Off)
2 = Report Delinquent (Turn Off)
3 = Report Tests (Leave On)
4 = Report Fuse Failure (Leave On)
5 = Report output fails (Leave On)
Check With Your Monitoring Station What They Need On.
Refer to Page 41-42 of the Technician’s Handbook
Exit Programming Mode
Press Program then Enter.
31
BACK UP NUMBER
Press Program then 181 then Enter. Then Enter 2 Then Enter. Then press Phone Number
(Up to 16 Digits) then Enter.
Press Program then 184 then Enter. Then press 2 then Enter, Number 3 will flash . Then Press 6
then press Enter
Enter the same as the primary number
Press Program then 186 then Enter. Then 1 then Enter.
1 = Report Mains Failure (Leave On)
2 = Report Low battery (Leave On)
3 = Report Wireless Battery (Leave On)
4 = Report Line Failure (Leave On)
5 = Report System Tamper (Leave On)
6 = Report Key pad Tam (Leave On)
7 = Report Zone Tamper (Leave On)
8 = Report Radio Tamper (Leave On)
Press Program then 187 then Enter. Then 1 then Enter.
1 = Report Duress Alarm (Leave On)
2 = Report Radio (Leave On)
3 = Report Sensor watch (Leave On)
4 = Report panic (Leave On)
5 = Report Fire (Leave On)
6 = Report Medical (Leave On)
7 = Report Radio Panic (Leave On)
8 = Zone bypasses (Leave On)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Press Program then 188 then Enter. Then 1 then Enter
1 = Report Open / Close (Turn Off)
2 = Report Stay Open / Close (Turn Off)
3 = Report Open after Alarm (Turn Off)
4 = Report Stay Open after Alarm (Turn Off)
5 = Report Alarm in Stay (Turn Off)
6 = Report Access programming (Leave Off)
7 = Report 24 hr alarm (leave On)
8 = Report Restores (Leave On)
Press the numbers that you want Off so the lights are Out.
The lights that are On are the only reports that you will get. Then press Enter.
Press Program then 189 then Enter.
1 = Report latch (Turn Off)
2 = Report Delinquent (Turn Off)
3 = Report Tests (Leave On)
4 = Report Fuse Failure (Leave On)
5 = Report output fails (Leave On)
Check With Your Monitoring Station What They Need On.
Refer to Page 41-42 of the Technician’s handbook.
Exit Programming Mode
Press Program then Enter.
32
Siren
Red to Output 1
Strobe
White To Output
2
Power
Brown To 12 volt
2.2 K RESISTOR
PIR No 1 Indoor Siren
Black to
Output 1
In Door Siren
Red to
12 Volt
tam
per
12 V
Crow Runner Alarm Panel
4 &
8
C
C
GN
D
3 &
7
2 &
6
1 &
5
12 V
POS
NEG
CLK
DAT
LIN
GN
D
IN
AC
EARTH
16 VOLT
Power Supply
Key Pad
Runner
GN
D
12 V
2
1
A B C D E F
12 V
TA
MP
TA
MP
0 V
ALA
RM
ALA
RM
4.7k 2.2k