Creation Date 30-Aug-2011 Revision Date 22-Nov-2011 Revision Number 2
Kit Safety Data Sheet Product Name: PathoDxtra Strep Grouping Kit
Product Code: DR0700M
Component Safety Data Sheets for Kit
DR0701G-0706G PathoDxtra Strep A, B, C, D, F, G Group Latex Yes DR0707G PathoDxtra Positive Control Yes DR0709A PathoDxtra Extraction Reagent 1 Yes DR0709B PathoDxtra Extraction Reagent 2 Yes DR0709C PathoDxtra Extraction Reagent 3 Yes
Code Component Name SDS Required*
Kit Transport Information UN-No. Not Regulated Hazard Class - Packing Group - Proper Shipping Name -
Emergency contact information: Company Identification: Oxoid Ltd. Wade Road, Basingstoke, Hants, RG24 8PW United Kingdom Company Phone Number: +44 (0) 1256 841144 Emergency Telephone Number Carechem 24: +44 (0) 1865 407333 Email: [email protected] * Kit components labelled as not required above are not included in this SDS and are considered non-hazardous.
1/36
1/36
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING
Product Name PathoDxtra Strep A, B, C, D, F, G Group LatexCat No. DR0701 - DR0706Synonyms No information available.Recommended Use Laboratory chemicals
Emergency Telephone Number Carechem 24: +44 (0) 1865 407333
2. HAZARDS IDENTIFICATION
The preparation is classified as dangerous in accordance with Directive 1999/45/EC.
R -phrase(s)R43 - May cause sensitization by skin contact
3. COMPOSITION/INFORMATION ON INGREDIENTS Haz/Non-haz
Component Weight % EC No. Classification Sodium azide 26628-22-8
0.098 EEC No. 247-852-1 T+; R28 R32
N; R50-53ProClin 300 55965-84-9
0.05 - T; R23/24/25 C; R34
R43 N; R50-53
_____________________________________________________________________________________________ Thermo Fisher Scientific
Creation Date 30-Aug-2011
Entity / Business Name Oxoid Ltd.Wade RoadBasingstoke, Hants, UKRG24 8PWTelephone: +44 (0) 1256 841144
E-mail address [email protected]
Revision Date 31-Aug-2011 Revision Number 1
SAFETY DATA SHEET
Page 1 / 7 According to EC Directive 1907/2006/EC
Company REMEL (EUROPE) LIMITEDRemel HouseClipper Boulevard WestCrossways, DartfordKent. DA2 6PTUKTel: (+44) 1322 295600Fax: (+44) 1322 [email protected]
2/36
2/36
_____________________________________________________________________________________________ For the full text of the R phrases mentioned in this Section, see Section 16
4. FIRST AID MEASURES
Eye Contact Rinse thoroughly with plenty of water, also under the eyelids. Get medical attention if
symptoms occur.. Skin Contact Wash off immediately with soap and plenty of water. Get medical attention if symptoms occur.. Ingestion Clean mouth with water and afterwards drink plenty of water. Get medical attention. Inhalation Move to fresh air. Get medical attention if symptoms occur.. Notes to Physician Treat symptomatically.
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing MediaUse extinguishing measures that are appropriate to local circumstances and the surrounding environment Extinguishing media which must not be used for safety reasonsNo information available. Specific Hazards Arising from the ChemicalKeep product and empty container away from heat and sources of ignition Protective Equipment and Precautions for FirefightersAs in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear Flash Point Not applicableMethod No information available. Autoignition Temperature No information available.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions Avoid contact with skin, eyes and clothing. Ensure adequate ventilation. Environmental Precautions Prevent further leakage or spillage if safe to do so Methods for Containment and Clean Up
Soak up with inert absorbent material. Clean contaminated surface thoroughly
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Strep A, B, C, D, F, G Group Latex
Page 2 / 7 According to EC Directive 1907/2006/EC
Revision Date 31-Aug-2011
3/36
3/36
_____________________________________________________________________________________________
7. HANDLING AND STORAGE
Handling Avoid contact with skin, eyes and clothing. Ensure adequate ventilation. Storage Keep container tightly closed. Keep at temperatures between 2° and 8 °C. Specific use(s) No information available.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION Exposure limits
Component European Union The United Kingdom
Belgium France Spain Germany
Sodium azide SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
VME: 0.1 mg/m3 VLCT: 0.3 mg/m3
Skin
Skin VLA-EC: 0.3 mg/m3 VLA-ED: 0.1 mg/m3
MAK 0.2 mg/m3 (inhalable)
Component Italy Portugal The Netherlands Finland AustriaSodium azide TWA: 0.1 mg/m3
STEL: 0.3 mg/m3 Skin
Ceiling: 0.29 mg/m3 Ceiling: 0.11 ppm
Skin STEL: 0.3 mg/m3 TWA: 0.1 mg/m3
TWA: 0.1 mg/m3 STEL: 0.3 mg/m3
Skin
Skin STEL: 0.3 mg/m3 MAK: 0.1 mg/m3
Component Switzerland Poland Norway Ireland Denmark Australia Sodium azide STEL: 0.4 mg/m3
MAK: 0.2 mg/m3NDSCh: 0.3 mg/m3
NDS: 0.1 mg/m3Skin
Ceiling: 0.3 mg/m3TWA: 0.1 mg/m3 STEL: 0.3 mg/m3
Skin
TWA: 0.1 mg/m3 Skin
CL 0.11 ppm (0.3 mg/m3)
Occupational exposure controls Engineering Measures Ensure adequate ventilation, especially in confined areas Personal Protective Equipment Respiratory Protection Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN
149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced
Eye Protection Tightly fitting safety goggles Skin and body protection Wear appropriate protective gloves and clothing to prevent skin exposure Hand Protection Protective gloves
Hygiene Measures Handle in accordance with good industrial hygiene and safety practice Environmental exposure controls No information available.
9. PHYSICAL AND CHEMICAL PROPERTIES
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Strep A, B, C, D, F, G Group Latex
Page 3 / 7
Revision Date 31-Aug-2011
According to EC Directive 1907/2006/EC
4/36
4/36
_____________________________________________________________________________________________
9. PHYSICAL AND CHEMICAL PROPERTIESPhysical State LiquidAppearance BluepH 7.0 Boiling Point/Range Not applicableMelting Point/Range No information available.Flash Point Not applicable
10. STABILITY AND REACTIVITY
Stability Stable under recommended storage conditions. Conditions to Avoid Incompatible products Incompatible Materials Strong oxidizing agents Hazardous Decomposition Products None under normal use Hazardous Polymerization No information available Hazardous Reactions . None under normal processing.
11. TOXICOLOGICAL INFORMATION
Acute Toxicity
Component Information
Component LD50 Oral LD50 Dermal LC50 InhalationSodium azide 27 mg/kg ( Rat ) 20 mg/kg ( Rabbit )
50 mg/kg ( Rat )ProClin 300 53 mg/kg ( Rat )
Chronic Toxicity Carcinogenicity There are no known carcinogenic chemicals in this product
Sensitization May cause sensitization by skin contact. Neurological Effects No information available. Mutagenic Effects No information available.
_____________________________________________________________________________________________ Thermo Fisher Scientific
Revision Date 31-Aug-2011
Page 4 / 7
SAFETY DATA SHEET
According to EC Directive 1907/2006/EC
PathoDxtra Strep A, B, C, D, F, G Group Latex
5/36
5/36
_____________________________________________________________________________________________ Reproductive Effects No information available. Developmental Effects No information available. Target Organs No information available.
12. ECOLOGICAL INFORMATION
Ecotoxicity.
Component Freshwater Algae Freshwater Fish Microtox Water FleaSodium azide 0.8 mg/L LC50 96 h
0.7 mg/L LC50 96 h 5.46 mg/L LC50 96 h
ProClin 300 EC50 = 5.7 mg/L 16 h Persistence and Degradability No information available Bioaccumulative Potential No information available. Mobility No information available.
13. DISPOSAL CONSIDERATIONS
Waste from Residues / Unused Products
Dispose of as hazardous waste in compliance with local and national regulations
Contaminated Packaging Empty containers should be taken for local recycling, recovery or waste disposal
14. TRANSPORT INFORMATION
IMDG/IMO Not regulated
ADR Not regulated
IATA Not regulated
_____________________________________________________________________________________________ Thermo Fisher Scientific
PathoDxtra Strep A, B, C, D, F, G Group Latex Revision Date 31-Aug-2011
Page 5 / 7 According to EC Directive 1907/2006/EC
SAFETY DATA SHEET 6/36
6/36
_____________________________________________________________________________________________
15. REGULATORY INFORMATION
The preparation is classified as dangerous in accordance with Directive 1999/45/EC Labelling
R -phrase(s)R43 - May cause sensitization by skin contact
S -phrase(s) S24/25 - Avoid contact with skin and eyes
International Inventories
Component EINECS ELINCS NLP TSCA DSL NDSL PICCS ENCS CHINA AICS KECL Sodium azide 247-852-1 - X X - X X X X XProClin 300 - - - X - X - X - X
16. OTHER INFORMATION
Text of R phrases mentioned in Section 2-3R28 - Very toxic if swallowedR32 - Contact with acids liberates very toxic gasR34 - Causes burnsR43 - May cause sensitization by skin contactR23/24/25 - Toxic by inhalation, in contact with skin and if swallowedR50/53 - Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment
Prepared By Regulatory Affairs Creation Date 30-Aug-2011 Revision Date 31-Aug-2011 Revision Summary "***", and red text indicates revision Restrictions on use No information available.
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Strep A, B, C, D, F, G Group Latex Revision Date 31-Aug-2011
Page 6 / 7 According to EC Directive 1907/2006/EC
7/36
7/36
_____________________________________________________________________________________________ Training advice No information available. Literary reference No information available. Disclaimer The information provided on this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.
End of Safety Data Sheet
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
Page 7 / 7
PathoDxtra Strep A, B, C, D, F, G Group Latex
According to EC Directive 1907/2006/EC
Revision Date 31-Aug-2011
8/36
8/36
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING
Product Name PathoDxtra Positive ControlCat No. DR0707Synonyms No information available.Recommended Use Laboratory chemicals
Emergency Telephone Number Carechem 24: +44 (0) 1865 407333
2. HAZARDS IDENTIFICATION
The preparation is non-dangerous in accordance with Directive 1999/45/EC.
R -phrase(s)none
3. COMPOSITION/INFORMATION ON INGREDIENTS Haz/Non-haz
Component Weight % EC No. Classification Sodium azide 26628-22-8
0.098 EEC No. 247-852-1 T+; R28 R32
N; R50-53 For the full text of the R phrases mentioned in this Section, see Section 16
_____________________________________________________________________________________________ Thermo Fisher Scientific
Company REMEL (EUROPE) LIMITEDRemel HouseClipper Boulevard WestCrossways, DartfordKent. DA2 6PTUKTel: (+44) 1322 295600Fax: (+44) 1322 [email protected]
Creation Date 30-Aug-2011
Entity / Business Name Oxoid Ltd.Wade RoadBasingstoke, Hants, UKRG24 8PWTelephone: +44 (0) 1256 841144
E-mail address [email protected]
Revision Date 30-Aug-2011 Revision Number 1
Page 1 / 7 According to EC Directive 1907/2006/EC
SAFETY DATA SHEET 9/36
9/36
_____________________________________________________________________________________________
4. FIRST AID MEASURES
Eye Contact Rinse thoroughly with plenty of water, also under the eyelids. Get medical attention if
symptoms occur.. Skin Contact Wash off immediately with soap and plenty of water. Get medical attention if symptoms occur.. Ingestion Clean mouth with water and afterwards drink plenty of water. Get medical attention. Inhalation Move to fresh air Notes to Physician Treat symptomatically.
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing MediaUse extinguishing measures that are appropriate to local circumstances and the surrounding environment Extinguishing media which must not be used for safety reasonsNo information available. Specific Hazards Arising from the ChemicalKeep product and empty container away from heat and sources of ignition Protective Equipment and Precautions for FirefightersAs in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear Flash Point Not applicableMethod No information available. Autoignition Temperature No information available.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions Avoid contact with the skin and the eyes. Use personal protective equipment. Ensure adequate
ventilation. Environmental Precautions Prevent further leakage or spillage if safe to do so Methods for Containment and Clean Up
Soak up with inert absorbent material Clean contaminated surface thoroughly
_____________________________________________________________________________________________ Thermo Fisher Scientific
Revision Date 30-Aug-2011
Page 2 / 7
SAFETY DATA SHEET
According to EC Directive 1907/2006/EC
PathoDxtra Positive Control
10/36
10/36
_____________________________________________________________________________________________
7. HANDLING AND STORAGE
Handling Avoid contact with skin, eyes and clothing. Wear personal protective equipment. Storage Keep container tightly closed in a dry and well-ventilated place Specific use(s) No information available.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION Exposure limits
Component European Union The United Kingdom
Belgium France Spain Germany
Sodium azide SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
VME: 0.1 mg/m3 VLCT: 0.3 mg/m3
Skin
Skin VLA-EC: 0.3 mg/m3 VLA-ED: 0.1 mg/m3
MAK 0.2 mg/m3 (inhalable)
Component Italy Portugal The Netherlands Finland AustriaSodium azide TWA: 0.1 mg/m3
STEL: 0.3 mg/m3 Skin
Ceiling: 0.29 mg/m3 Ceiling: 0.11 ppm
Skin STEL: 0.3 mg/m3 TWA: 0.1 mg/m3
TWA: 0.1 mg/m3 STEL: 0.3 mg/m3
Skin
Skin STEL: 0.3 mg/m3 MAK: 0.1 mg/m3
Component Switzerland Poland Norway Ireland Denmark Australia Sodium azide STEL: 0.4 mg/m3
MAK: 0.2 mg/m3NDSCh: 0.3 mg/m3
NDS: 0.1 mg/m3Skin
Ceiling: 0.3 mg/m3TWA: 0.1 mg/m3 STEL: 0.3 mg/m3
Skin
TWA: 0.1 mg/m3 Skin
CL 0.11 ppm (0.3 mg/m3)
Occupational exposure controls Engineering Measures Ensure adequate ventilation, especially in confined areas Personal Protective Equipment Respiratory Protection Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN
149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced
Eye Protection Tightly fitting safety goggles Skin and body protection Wear appropriate protective gloves and clothing to prevent skin exposure Hand Protection Protective gloves
Hygiene Measures Handle in accordance with good industrial hygiene and safety practice Environmental exposure controls No information available.
9. PHYSICAL AND CHEMICAL PROPERTIES
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Positive Control
Page 3 / 7
Revision Date 30-Aug-2011
According to EC Directive 1907/2006/EC
11/36
11/36
_____________________________________________________________________________________________
9. PHYSICAL AND CHEMICAL PROPERTIESPhysical State LiquidAppearance ColourlesspH 7.3 - 7.5 Boiling Point/Range Not applicableMelting Point/Range No information available.Flash Point Not applicable
10. STABILITY AND REACTIVITY
Stability Stable under recommended storage conditions. Conditions to Avoid Incompatible products Incompatible Materials Strong oxidizing agents Hazardous Decomposition Products Nitrogen oxides (NOx), Carbon oxides Hazardous Polymerization No information available Hazardous Reactions . None under normal processing.
11. TOXICOLOGICAL INFORMATION
Acute Toxicity Product Information Product does not present an acute toxicity hazard based on known or supplied information
Component Information
Component LD50 Oral LD50 Dermal LC50 InhalationSodium azide 27 mg/kg ( Rat ) 20 mg/kg ( Rabbit )
50 mg/kg ( Rat ) Chronic Toxicity Carcinogenicity There are no known carcinogenic chemicals in this product
Sensitization No information available. Neurological Effects No information available. Mutagenic Effects No information available.
_____________________________________________________________________________________________ Thermo Fisher Scientific
PathoDxtra Positive Control Revision Date 30-Aug-2011
Page 4 / 7 According to EC Directive 1907/2006/EC
SAFETY DATA SHEET 12/36
12/36
_____________________________________________________________________________________________ Reproductive Effects No information available. Developmental Effects No information available. Target Organs No information available.
12. ECOLOGICAL INFORMATION
EcotoxicityNot established. However, at the concentration present, this preparation is not expected to present significant adverse environmental effects.
Component Freshwater Algae Freshwater Fish Microtox Water FleaSodium azide 0.8 mg/L LC50 96 h
0.7 mg/L LC50 96 h 5.46 mg/L LC50 96 h
Persistence and Degradability No information available Bioaccumulative Potential No information available. Mobility No information available.
13. DISPOSAL CONSIDERATIONS
Waste from Residues / Unused Products
Dispose of in accordance with local regulations
Contaminated Packaging Empty containers should be taken for local recycling, recovery or waste disposal
14. TRANSPORT INFORMATION
IMDG/IMO Not regulated
ADR Not regulated
IATA Not regulated
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Positive Control
Page 5 / 7 According to EC Directive 1907/2006/EC
Revision Date 30-Aug-2011
13/36
13/36
_____________________________________________________________________________________________
15. REGULATORY INFORMATION
The preparation is non-dangerous in accordance with Directive 1999/45/EC Labelling
R -phrase(s)none
S -phrase(s) S24/25 - Avoid contact with skin and eyes
International Inventories
Component EINECS ELINCS NLP TSCA DSL NDSL PICCS ENCS CHINA AICS KECL Sodium azide 247-852-1 - X X - X X X X X
16. OTHER INFORMATION
Text of R phrases mentioned in Section 2-3R28 - Very toxic if swallowedR32 - Contact with acids liberates very toxic gasR50/53 - Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment
Prepared By Regulatory Affairs Creation Date 30-Aug-2011 Revision Date 30-Aug-2011 Revision Summary "***", and red text indicates revision Restrictions on use No information available. Training advice No information available. Literary reference No information available. Disclaimer The information provided on this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Positive Control
Page 6 / 7 According to EC Directive 1907/2006/EC
Revision Date 30-Aug-2011
14/36
14/36
_____________________________________________________________________________________________
End of Safety Data Sheet
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Positive Control
Page 7 / 7 According to EC Directive 1907/2006/EC
Revision Date 30-Aug-2011
15/36
15/36
1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Product Name PathoDxtra Extraction Reagent 1Cat No. DR0709ASynonyms No information available.Recommended Use Laboratory chemicals
Emergency Telephone Number Carechem 24: +44 (0) 1865 407333
2. HAZARDS IDENTIFICATION
The preparation is classified as dangerous in accordance with Directive 1999/45/EC.
R-phrase(s)R25 - Toxic if swallowed
3. COMPOSITION/INFORMATION ON INGREDIENTS Haz/Non-haz
Component Weight % EC-No. Classification Sodium nitrite
7632-00-06.9 EEC No. 231-555-9 T; R25
N; R50 O; R8
Sodium azide 26628-22-8
0.098 EEC No. 247-852-1 T+; R28 R32
N; R50-53
_____________________________________________________________________________________________ Thermo Fisher Scientific
Creation Date 30-Aug-2011
Entity / Business Name Oxoid Ltd.Wade RoadBasingstoke, Hants, UKRG24 8PWTelephone: +44 (0) 1256 841144
E-mail address [email protected]
Revision Date 22-Nov-2011 Revision Number 2
SAFETY DATA SHEET
Page 1 / 7 According to EC Directive 1907/2006/EC
Company REMEL (EUROPE) LIMITEDRemel HouseClipper Boulevard WestCrossways, DartfordKent. DA2 6PTUKTel: (+44) 1322 295600Fax: (+44) 1322 [email protected]
16/36
16/36
_____________________________________________________________________________________________ For the full text of the R phrases mentioned in this Section, see Section 16
4. FIRST AID MEASURES
Eye Contact Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get
medical attention if irritation persists.. Skin Contact Wash off immediately with soap and plenty of water. Get medical attention if irritation develops
and persists.. Ingestion Clean mouth with water and drink afterwards plenty of water. Call a physician or Poison Control
Centre immediately. Inhalation Move to fresh air. If symptoms persist, obtain medical attention.. Notes to Physician Treat symptomatically.
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing MediaUse extinguishing measures that are appropriate to local circumstances and the surrounding environment Extinguishing media which must not be used for safety reasonsNo information available. Specific Hazards Arising from the ChemicalKeep product and empty container away from heat and sources of ignition Protective Equipment and Precautions for FirefightersAs in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear Flash Point No information available.Method No information available. Autoignition Temperature No information available.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions Ensure adequate ventilation. Use personal protective equipment. Environmental Precautions Prevent further leakage or spillage if safe to do so Methods for Containment and Clean Up
Soak up with inert absorbent material After cleaning, flush away traces with water
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Extraction Reagent 1
Page 2 / 7 According to EC Directive 1907/2006/EC
Revision Date 22-Nov-2011
17/36
17/36
_____________________________________________________________________________________________
7. HANDLING AND STORAGE
Handling Avoid contact with skin, eyes and clothing. Ensure adequate ventilation. Storage Keep at temperatures between 2° and 8 °C. Specific use(s) No information available.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION Exposure limits
Component European Union The United Kingdom
Belgium France Spain Germany
Sodium azide SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
VME: 0.1 mg/m3 8 heures. restrictive
limit VLCT: 0.3 mg/m3
Skin
Skin VLA-EC: 0.3 mg/m3
15 minutos VLA-ED: 0.1 mg/m3
8 horas
MAK 0.2 mg/m3 (inhalable)
Component Italy Portugal The Netherlands Finland AustriaSodium azide TWA: 0.1 mg/m3 8 ore.
STEL: 0.3 mg/m3 15 minuti. Skin
Ceiling: 0.29 mg/m3 Ceiling: 0.11 ppm
Skin STEL: 0.3 mg/m3 15
minuten TWA: 0.1 mg/m3 8 uren
TWA: 0.1 mg/m3 8 tunteina
STEL: 0.3 mg/m3 15 minuutteina
Skin
Skin STEL: 0.3 mg/m3 15
Minuten MAK: 0.1 mg/m3 8
Stunden
Component Switzerland Poland Norway Ireland Denmark Australia Sodium azide STEL: 0.4 mg/m3 15
Minuten MAK: 0.2 mg/m3 8
Stunden
NDSCh: 0.3 mg/m3 15 minutach
NDS: 0.1 mg/m3 8 godzinach
Skin Ceiling: 0.3 mg/m3
TWA: 0.1 mg/m3 8 hr. NaN3
STEL: 0.3 mg/m3 15 min Skin
TWA: 0.1 mg/m3 8 timer Skin
CL 0.11 ppm (0.3 mg/m3)
_____________________________________________________________________________________________ Thermo Fisher Scientific
PathoDxtra Extraction Reagent 1 Revision Date 22-Nov-2011
Page 3 / 7 According to EC Directive 1907/2006/EC
SAFETY DATA SHEET 18/36
18/36
_____________________________________________________________________________________________ Occupational exposure controls Engineering Measures Ensure adequate ventilation, especially in confined areas Personal Protective Equipment Respiratory Protection Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN
149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced
Eye Protection Tightly fitting safety goggles Skin and body protection Wear appropriate protective gloves and clothing to prevent skin exposure Hand Protection Protective gloves
Hygiene Measures Handle in accordance with good industrial hygiene and safety practice Environmental exposure controls No information available.
9. PHYSICAL AND CHEMICAL PROPERTIES
Physical State LiquidAppearance BluepH 9.2 Boiling Point/Range Not applicableMelting Point/Range No information available.Flash Point No information available.
10. STABILITY AND REACTIVITY
Stability Stable under recommended storage conditions. Conditions to Avoid Temperatures above 537°C. Incompatible Materials Combustible material, Strong oxidizing agents Hazardous Decomposition Products Carbon oxides, Nitrogen oxides (NOx) Hazardous Polymerization Hazardous polymerization does not occur. Hazardous Reactions . None under normal processing.
11. TOXICOLOGICAL INFORMATION
Acute Toxicity Product Information Product is toxic by ingestion
_____________________________________________________________________________________________ Thermo Fisher Scientific
Revision Date 22-Nov-2011
Page 4 / 7
SAFETY DATA SHEET
According to EC Directive 1907/2006/EC
PathoDxtra Extraction Reagent 1
19/36
19/36
_____________________________________________________________________________________________
Component Information
Component LD50 Oral LD50 Dermal LC50 InhalationSodium nitrite 85 mg/kg ( Rat ) 5.5 mg/L ( Rat ) 4 hSodium azide 27 mg/kg ( Rat ) 20 mg/kg ( Rabbit )
50 mg/kg ( Rat ) Chronic Toxicity Carcinogenicity The table below indicates whether each agency has listed any ingredient as a carcinogen
Component IARC UK Sodium nitrite Group 2A
IARC: (International Agency for Research on Cancer)IARC: (International Agency for Research on Cancer)Group 1 - Carcinogenic to HumansGroup 2A - Probably Carcinogenic to HumansGroup 2B - Possibly Carcinogenic to Humans
Sensitization No information available. Neurological Effects No information available. Mutagenic Effects No information available. Reproductive Effects No information available. Developmental Effects No information available. Target Organs No information available.
12. ECOLOGICAL INFORMATION
EcotoxicityVery toxic to aquatic organisms. However, at the concentration present, this preparation is not expected to present significant adverse environmental effects.
Component Freshwater Algae Freshwater Fish Microtox Water FleaSodium nitrite Oncorhynchus mykiss: LC50
= 0.09-0.13 mg/L 96h12.5-100 mg/L 48h
Sodium azide 0.8 mg/L LC50 96 h 0.7 mg/L LC50 96 h
5.46 mg/L LC50 96 h Persistence and Degradability No information available
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Extraction Reagent 1
Page 5 / 7
Revision Date 22-Nov-2011
According to EC Directive 1907/2006/EC
20/36
20/36
_____________________________________________________________________________________________ Bioaccumulative Potential No information available. Mobility No information available.
Component log PowSodium nitrite -3.7
13. DISPOSAL CONSIDERATIONS
Waste from Residues / Unused Products
Dispose of as hazardous waste in compliance with local and national regulations
Contaminated Packaging Dispose of in accordance with federal, state, and local regulations..
14. TRANSPORT INFORMATION
IMDG/IMO Not regulated
ADR Not regulated
IATA Not regulated
15. REGULATORY INFORMATION
The preparation is classified as dangerous in accordance with Directive 1999/45/EC Labelling
R-phrase(s)R25 - Toxic if swallowed
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Extraction Reagent 1 Revision Date 22-Nov-2011
Page 6 / 7 According to EC Directive 1907/2006/EC
21/36
21/36
_____________________________________________________________________________________________ S-phrase(s)S37 - Wear suitable glovesS45 - In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible)
International Inventories
Component EINECS ELINCS NLP TSCA DSL NDSL PICCS ENCS CHINA AICS KECL Sodium nitrite 231-555-9 - X X - X X X X XSodium azide 247-852-1 - X X - X X X X X
16. OTHER INFORMATION
Full text of R-phrases referred to under sections 2 and 3R 8 - Contact with combustible material may cause fireR25 - Toxic if swallowedR28 - Very toxic if swallowedR32 - Contact with acids liberates very toxic gasR50 - Very toxic to aquatic organismsR50/53 - Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment
Prepared By Regulatory Affairs Creation Date 30-Aug-2011 Revision Date 22-Nov-2011 Revision Summary (M)SDS sections updated: 14. Restrictions on use No information available. Training advice No information available. Literary reference No information available. Disclaimer The information provided on this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.
End of Safety Data Sheet
_____________________________________________________________________________________________ Thermo Fisher Scientific
PathoDxtra Extraction Reagent 1 Revision Date 22-Nov-2011
Page 7 / 7 According to EC Directive 1907/2006/EC
SAFETY DATA SHEET 22/36
22/36
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING
Product Name PathoDxtra Extraction Reagent 2Cat No. DR0709BSynonyms No information available.Recommended Use Laboratory chemicals
Emergency Telephone Number Carechem 24: +44 (0) 1865 407333
2. HAZARDS IDENTIFICATION
The preparation is non-dangerous in accordance with Directive 1999/45/EC.
R -phrase(s)none
3. COMPOSITION/INFORMATION ON INGREDIENTS Haz/Non-haz
Component Weight % EC No. Classification Acetic acid
64-19-78.6 EEC No. 200-580-7 R10
C; R35
For the full text of the R phrases mentioned in this Section, see Section 16
_____________________________________________________________________________________________ Thermo Fisher Scientific
Company REMEL (EUROPE) LIMITEDRemel HouseClipper Boulevard WestCrossways, DartfordKent. DA2 6PTUKTel: (+44) 1322 295600Fax: (+44) 1322 [email protected]
Creation Date 30-Aug-2011
Entity / Business Name Oxoid Ltd.Wade RoadBasingstoke, Hants, UKRG24 8PWTelephone: +44 (0) 1256 841144
E-mail address [email protected]
Revision Date 30-Aug-2011 Revision Number 1
Page 1 / 7 According to EC Directive 1907/2006/EC
SAFETY DATA SHEET 23/36
23/36
_____________________________________________________________________________________________
4. FIRST AID MEASURES
Eye Contact Rinse thoroughly with plenty of water, also under the eyelids. Obtain medical attention. Skin Contact Wash off immediately with plenty of water.. Obtain medical attention if irritation persists. Ingestion Clean mouth with water and afterwards drink plenty of water. Obtain medical attention. Inhalation Move to fresh air. Get medical attention if symptoms occur.. Notes to Physician Treat symptomatically.
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing MediaUse extinguishing measures that are appropriate to local circumstances and the surrounding environment Extinguishing media which must not be used for safety reasonsNo information available. Specific Hazards Arising from the ChemicalKeep product and empty container away from heat and sources of ignition Protective Equipment and Precautions for FirefightersAs in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear Flash Point Not applicableMethod No information available. Autoignition Temperature No information available.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions Avoid contact with skin, eyes and clothing. Ensure adequate ventilation. Environmental Precautions Prevent further leakage or spillage if safe to do so Methods for Containment and Clean Up
Soak up with inert absorbent material. Clean contaminated surface thoroughly
_____________________________________________________________________________________________ Thermo Fisher Scientific
Revision Date 30-Aug-2011
Page 2 / 7
SAFETY DATA SHEET
According to EC Directive 1907/2006/EC
PathoDxtra Extraction Reagent 2
24/36
24/36
_____________________________________________________________________________________________
7. HANDLING AND STORAGE
Handling Avoid contact with skin, eyes and clothing. Ensure adequate ventilation. Storage Keep container tightly closed. Keep at temperatures between 2° and 8 °C. Specific use(s) No information available.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION Exposure limits
Component European Union The United Kingdom
Belgium France Spain Germany
Acetic acid - STEL: 37 mg/m3 STEL: 15 ppm TWA: 10 ppm
TWA: 25 mg/m3
STEL: 15 ppm STEL: 38 mg/m3
TWA: 10 ppm TWA: 25 mg/m3
VLCT: 10 ppm VLCT: 25 mg/m3
VLA-EC: 15 ppm VLA-EC: 37 mg/m3 VLA-ED: 10 ppm
VLA-ED: 25 mg/m3
MAK: 10 ppm MAK: 25 mg/m3 Peak: 20 ppm
Peak: 50 mg/m3
Component Italy Portugal The Netherlands Finland AustriaAcetic acid - STEL: 15 ppm
TWA: 10 ppmMAC-TGG 25 mg/m3 TWA: 5 ppm
TWA: 13 mg/m3 STEL: 10 ppm
STEL: 25 mg/m3
STEL: 20 ppm STEL: 50 mg/m3
MAK: 10 ppm MAK: 25 mg/m3
Component Switzerland Poland Norway Ireland Denmark Australia Acetic acid STEL: 20 ppm
STEL: 50 mg/m3 MAK: 10 ppm
MAK: 25 mg/m3
NDSCh: 30 mg/m3 NDS: 15 mg/m3
TWA: 10 ppm TWA: 25 mg/m3
TWA: 10 ppm TWA: 25 mg/m3 STEL: 15 ppm
STEL: 37 mg/m3
TWA: 10 ppm TWA: 25 mg/m3
STEL: 15 ppm STEL: 37 mg/m3
TWA: 10 ppm TWA: 25 mg/m3
Occupational exposure controls Engineering Measures Ensure adequate ventilation, especially in confined areas Personal Protective Equipment Respiratory Protection Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN
149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced
Eye Protection Tightly fitting safety goggles Skin and body protection Wear appropriate protective gloves and clothing to prevent skin exposure Hand Protection Protective gloves
Hygiene Measures Handle in accordance with good industrial hygiene and safety practice Environmental exposure controls No information available.
_____________________________________________________________________________________________ Thermo Fisher Scientific
Revision Date 30-Aug-2011
Page 3 / 7
SAFETY DATA SHEET
According to EC Directive 1907/2006/EC
PathoDxtra Extraction Reagent 2
25/36
25/36
_____________________________________________________________________________________________
9. PHYSICAL AND CHEMICAL PROPERTIES
Physical State LiquidAppearance Purple pH 2.4 Boiling Point/Range Not applicableMelting Point/Range No information available.Flash Point Not applicable
10. STABILITY AND REACTIVITY
Stability Stable under recommended storage conditions. Conditions to Avoid Keep away from open flames, hot surfaces and sources of ignition. Incompatible Materials Strong oxidizing agents Hazardous Decomposition Products None under normal use Hazardous Polymerization No information available Hazardous Reactions . None under normal processing.
11. TOXICOLOGICAL INFORMATION
Acute Toxicity Product Information Product does not present an acute toxicity hazard based on known or supplied information
Component Information
Component LD50 Oral LD50 Dermal LC50 InhalationAcetic acid 3310 mg/kg ( Rat ) 1060 mg/kg ( Rabbit ) 11.4 mg/L ( Rat ) 4 h
Chronic Toxicity Carcinogenicity There are no known carcinogenic chemicals in this product
Sensitization No information available. Neurological Effects No information available. Mutagenic Effects No information available.
_____________________________________________________________________________________________ Thermo Fisher Scientific
Revision Date 30-Aug-2011
SAFETY DATA SHEET
Page 4 / 7 According to EC Directive 1907/2006/EC
PathoDxtra Extraction Reagent 2
26/36
26/36
_____________________________________________________________________________________________ Reproductive Effects No information available. Developmental Effects No information available. Target Organs Respiratory system, Eyes, Teeth, Skin.
12. ECOLOGICAL INFORMATION
Ecotoxicity.
Component Freshwater Algae Freshwater Fish Microtox Water FleaAcetic acid Pimephales promelas: LC50
= 88 mg/L/96hLepomis macrochirus: LC50 =
75 mg/L/96h
Photobacterium phosphoreum: EC50 = 8.8
mg/L/15 min Photobacterium
phosphoreum: EC50 = 8.8 mg/L/25 min
Photobacterium phosphoreum: EC50 = 8.8
mg/L/5 min
EC50 = 95 mg/L/24h
Persistence and Degradability No information available Bioaccumulative Potential No information available. Mobility No information available.
Component log PowAcetic acid -0.2
13. DISPOSAL CONSIDERATIONS
Waste from Residues / Unused Products
Dispose of in accordance with local regulations
Contaminated Packaging Empty containers should be taken for local recycling, recovery or waste disposal
14. TRANSPORT INFORMATION
IMDG/IMO Not regulated
ADR Not regulated
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Extraction Reagent 2
Page 5 / 7 According to EC Directive 1907/2006/EC
Revision Date 30-Aug-2011
27/36
27/36
_____________________________________________________________________________________________
14. TRANSPORT INFORMATIONIATA Not regulated
15. REGULATORY INFORMATION
The preparation is non-dangerous in accordance with Directive 1999/45/EC Labelling
R -phrase(s)none
S -phrase(s) S24/25 - Avoid contact with skin and eyes
International Inventories
Component EINECS ELINCS NLP TSCA DSL NDSL PICCS ENCS CHINA AICS KECL Acetic acid 200-580-7 - X X - X X X X X
16. OTHER INFORMATION
Text of R phrases mentioned in Section 2-3R10 - FlammableR35 - Causes severe burns
Prepared By Regulatory Affairs Creation Date 30-Aug-2011 Revision Date 30-Aug-2011 Revision Summary "***", and red text indicates revision Restrictions on use No information available. Training advice No information available. Literary reference No information available.
_____________________________________________________________________________________________ Thermo Fisher Scientific
PathoDxtra Extraction Reagent 2 Revision Date 30-Aug-2011
Page 6 / 7 According to EC Directive 1907/2006/EC
SAFETY DATA SHEET 28/36
28/36
_____________________________________________________________________________________________ Disclaimer The information provided on this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.
End of Safety Data Sheet
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Extraction Reagent 2
Page 7 / 7
Revision Date 30-Aug-2011
According to EC Directive 1907/2006/EC
29/36
29/36
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING
Product Name PathoDxtra Extraction Reagent 3Cat No. DR0709CSynonyms No information available.Recommended Use Laboratory chemicals
Emergency Telephone Number Carechem 24: +44 (0) 1865 407333
2. HAZARDS IDENTIFICATION
The preparation is non-dangerous in accordance with Directive 1999/45/EC.
R -phrase(s)none
3. COMPOSITION/INFORMATION ON INGREDIENTS Haz/Non-haz
Component Weight % EC No. Classification Tris (hydroxymethyl)
aminomethane 77-86-1
3.63 EEC No. 201-064-4 Xi; R36/37/38
Sodium azide 26628-22-8
0.098 EEC No. 247-852-1 T+; R28 R32
N; R50-53 For the full text of the R phrases mentioned in this Section, see Section 16
_____________________________________________________________________________________________ Thermo Fisher Scientific
Entity / Business Name Oxoid Ltd.Wade RoadBasingstoke, Hants, UKRG24 8PWTelephone: +44 (0) 1256 841144
E-mail address [email protected]
Revision Date 30-Aug-2011 Revision Number 1
SAFETY DATA SHEET
Page 1 / 7
Company
According to EC Directive 1907/2006/EC
REMEL (EUROPE) LIMITEDRemel HouseClipper Boulevard WestCrossways, DartfordKent. DA2 6PTUKTel: (+44) 1322 295600Fax: (+44) 1322 [email protected]
Creation Date 30-Aug-2011
30/36
30/36
_____________________________________________________________________________________________
4. FIRST AID MEASURES
Eye Contact Rinse thoroughly with plenty of water, also under the eyelids. Get medical attention if
symptoms occur.. Skin Contact Wash off immediately with soap and plenty of water. Get medical attention if symptoms occur.. Ingestion Clean mouth with water and afterwards drink plenty of water. Get medical attention. Inhalation Move to fresh air. Get medical attention if symptoms occur.. Notes to Physician Treat symptomatically.
5. FIRE-FIGHTING MEASURES
Suitable Extinguishing MediaUse extinguishing measures that are appropriate to local circumstances and the surrounding environment Extinguishing media which must not be used for safety reasonsNo information available. Specific Hazards Arising from the ChemicalKeep product and empty container away from heat and sources of ignition Protective Equipment and Precautions for FirefightersAs in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear Flash Point Not applicableMethod No information available. Autoignition Temperature No information available.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions Avoid contact with skin, eyes and clothing. Ensure adequate ventilation. Environmental Precautions Prevent further leakage or spillage if safe to do so Methods for Containment and Clean Up
Soak up with inert absorbent material. Clean contaminated surface thoroughly
_____________________________________________________________________________________________ Thermo Fisher Scientific
Revision Date 30-Aug-2011
Page 2 / 7
SAFETY DATA SHEET
According to EC Directive 1907/2006/EC
PathoDxtra Extraction Reagent 3
31/36
31/36
_____________________________________________________________________________________________
7. HANDLING AND STORAGE
Handling Avoid contact with skin, eyes and clothing. Ensure adequate ventilation. Storage Keep container tightly closed. Keep at temperatures between 2° and 8 °C. Specific use(s) No information available.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION Exposure limits
Component European Union The United Kingdom
Belgium France Spain Germany
Sodium azide SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
SkinTWA 0.1 mg/m3
STEL 0.3 mg/m3
VME: 0.1 mg/m3 VLCT: 0.3 mg/m3
Skin
Skin VLA-EC: 0.3 mg/m3 VLA-ED: 0.1 mg/m3
MAK 0.2 mg/m3 (inhalable)
Component Italy Portugal The Netherlands Finland AustriaSodium azide TWA: 0.1 mg/m3
STEL: 0.3 mg/m3 Skin
Ceiling: 0.29 mg/m3 Ceiling: 0.11 ppm
Skin STEL: 0.3 mg/m3 TWA: 0.1 mg/m3
TWA: 0.1 mg/m3 STEL: 0.3 mg/m3
Skin
Skin STEL: 0.3 mg/m3 MAK: 0.1 mg/m3
Component Switzerland Poland Norway Ireland Denmark Australia Sodium azide STEL: 0.4 mg/m3
MAK: 0.2 mg/m3NDSCh: 0.3 mg/m3
NDS: 0.1 mg/m3Skin
Ceiling: 0.3 mg/m3TWA: 0.1 mg/m3 STEL: 0.3 mg/m3
Skin
TWA: 0.1 mg/m3 Skin
CL 0.11 ppm (0.3 mg/m3)
Occupational exposure controls Engineering Measures Ensure adequate ventilation, especially in confined areas Personal Protective Equipment Respiratory Protection Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN
149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced
Eye Protection Tightly fitting safety goggles Skin and body protection Wear appropriate protective gloves and clothing to prevent skin exposure Hand Protection Protective gloves
Hygiene Measures Handle in accordance with good industrial hygiene and safety practice Environmental exposure controls No information available.
9. PHYSICAL AND CHEMICAL PROPERTIES
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Extraction Reagent 3
Page 3 / 7
Revision Date 30-Aug-2011
According to EC Directive 1907/2006/EC
32/36
32/36
_____________________________________________________________________________________________
9. PHYSICAL AND CHEMICAL PROPERTIESPhysical State LiquidAppearance ClearpH 10.6 Boiling Point/Range Not applicableMelting Point/Range No information available.Flash Point Not applicable
10. STABILITY AND REACTIVITY
Stability Stable under recommended storage conditions. Conditions to Avoid Incompatible products Incompatible Materials Strong oxidizing agents Hazardous Decomposition Products None under normal use Hazardous Polymerization No information available Hazardous Reactions . None under normal processing.
11. TOXICOLOGICAL INFORMATION
Acute Toxicity Product Information Product does not present an acute toxicity hazard based on known or supplied information
Component Information
Component LD50 Oral LD50 Dermal LC50 InhalationTris (hydroxymethyl) aminomethane 5900 mg/kg ( Rat )
Sodium azide 27 mg/kg ( Rat ) 20 mg/kg ( Rabbit ) 50 mg/kg ( Rat )
Chronic Toxicity Carcinogenicity There are no known carcinogenic chemicals in this product
Sensitization No information available. Neurological Effects No information available. Mutagenic Effects No information available.
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
Page 4 / 7
PathoDxtra Extraction Reagent 3
According to EC Directive 1907/2006/EC
Revision Date 30-Aug-2011
33/36
33/36
_____________________________________________________________________________________________ Reproductive Effects No information available. Developmental Effects No information available. Target Organs No information available.
12. ECOLOGICAL INFORMATION
Ecotoxicity.
Component Freshwater Algae Freshwater Fish Microtox Water FleaSodium azide 0.8 mg/L LC50 96 h
0.7 mg/L LC50 96 h 5.46 mg/L LC50 96 h
Persistence and Degradability No information available Bioaccumulative Potential No information available. Mobility No information available.
13. DISPOSAL CONSIDERATIONS
Waste from Residues / Unused Products
Dispose of in accordance with local regulations
Contaminated Packaging Empty containers should be taken for local recycling, recovery or waste disposal
14. TRANSPORT INFORMATION
IMDG/IMO Not regulated
ADR Not regulated
IATA Not regulated
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Extraction Reagent 3
Page 5 / 7 According to EC Directive 1907/2006/EC
Revision Date 30-Aug-2011
34/36
34/36
_____________________________________________________________________________________________
15. REGULATORY INFORMATION
The preparation is non-dangerous in accordance with Directive 1999/45/EC Labelling
R -phrase(s)none
S -phrase(s) S24/25 - Avoid contact with skin and eyes
International Inventories
Component EINECS ELINCS NLP TSCA DSL NDSL PICCS ENCS CHINA AICS KECL Tris (hydroxymethyl) aminomethane
201-064-4 - X X - X X X X X
Sodium azide 247-852-1 - X X - X X X X X
16. OTHER INFORMATION
Text of R phrases mentioned in Section 2-3R28 - Very toxic if swallowedR32 - Contact with acids liberates very toxic gasR36/37/38 - Irritating to eyes, respiratory system and skinR50/53 - Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment
Prepared By Regulatory Affairs Creation Date 30-Aug-2011 Revision Date 30-Aug-2011 Revision Summary "***", and red text indicates revision Restrictions on use No information available. Training advice No information available. Literary reference No information available.
_____________________________________________________________________________________________ Thermo Fisher Scientific
Revision Date 30-Aug-2011
SAFETY DATA SHEET
Page 6 / 7 According to EC Directive 1907/2006/EC
PathoDxtra Extraction Reagent 3
35/36
35/36
_____________________________________________________________________________________________ Disclaimer The information provided on this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text.
End of Safety Data Sheet
_____________________________________________________________________________________________ Thermo Fisher Scientific
SAFETY DATA SHEET
PathoDxtra Extraction Reagent 3
Page 7 / 7
Revision Date 30-Aug-2011
According to EC Directive 1907/2006/EC
36/36
36/36