6 • Crankcase Ventilation
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Crankcase Ventilation Manager (CVM) . . . . . . . . . . . . . . 6-5Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6CVM280B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7CVM280T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10CVM424B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13CVM424T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16
Crankcase Ventilation Filter . . . . . . . . . . . . . . . . . . . . . . 6-19CV51118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19
Recirculators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2393194A • 93192A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2393194A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2593192A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-26
Crankcase Ventilation Breathers . . . . . . . . . . . . . . . . . . 6-27CV50111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-27CV50202 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-30
6-3cumminsfiltration.com
Clearing the Air with Crankcase VentilationDue to the growing importance of safeguarding our global environment, efficient crankcase ventilation filtration systems are increasingly critical to diesel engine Original Equipment Manufacturers (OEMs) . Future worldwide diesel engine emission regulations will require OEMs to continue to reduce total particulate emissions . Current emission regulations in some regions and market segments cover total engine emissions, which include both tailpipe and crankcase . Since crankcase emissions can contribute up to 25% of total emissions, control of this air pollution source is critical to the protection of the earth’s environment .
Blow-by: An Increasingly Significant Environmental ImpactA significant contributor to environmental degradation is engine crankcase blow-by . During diesel engine operation, blow-by is generated by the leakage of combustion gases past piston rings . The blow-by is typically laden with oil droplets which can be divided into two classes based on particle size:
1 . Drip (visible drips or puddles of oil)
2 . Aerosol (sub-micron oil drops that create the oily “smoke” seen at the crankcase vent)
During engine operation, the concentrations of oil droplets between 3 and 20 μm tends to be low . As a percentage of total mass, most of the oil is present either as large drips or as aerosol particles smaller than 3 μm . The major challenge for crankcase ventilation filtration is the removal of aerosol particles . A considerable portion of aerosol particles are in the 0 .2 to 0 .3 μm size range, the size of maximum penetration or are in the size range of 0 .2 to 3 .0 um . This size range creates a significant challenge for all but the most advanced crankcase ventilation filtration products such as the coalescing technology provided by Cummins Filtration® .
Without adequate and effective filtration, significant amounts of aerosol may be present in blow-by . Crankcase gases must be particularly well cleaned in order to minimize turbocharger and intercooler deposits and fouling, as well as to reduce particulate loading on the exhaust aftertreatment system .
There are two basic ways of venting crankcase emissions, either into the atmosphere – Open Crankcase Ventilation (OCV) – or routing the crankcase gases back into the engine air intake system – Closed Crankcase Ventilation (CCV) . Cummins Filtration offers both OCV and CCV approaches to manage crankcase blow-by on diesel engines .
Leading the Way with the Right TechnologiesCummins Filtration has emerged with twelve US patents on or related to CV filtration, plus some related ancillary patents . Our CV patents cover coalescers, impactors and Electrostatic Droplet Collector (EDC) devices . The company also holds a patent on a rotating coalescer design and eight patents based on coalescer technology, alone or in combination with an impactor . A number of patent applications covering other CV technologies are awaiting approval .
Depending on customer requirements, our CV products may be used alone, with performance enhancing features, or in combination with other technologies to achieve desired levels of performance . Today, they are used on nearly every major make of on-highway and industrial diesel and natural gas engine in North America and Europe .
Cummins Filtration Crankcase Ventilation systems are innovative products which are specifically designed to provide the type of performance the marketplace and the environment requires .
Product features include:
• Superior aerosol filtration, 98+% efficiency
• No service required for the impactor
• Easy service access
• Easy installation
• Durability
• Integrated electronic sensor
• Easy and versatile engine and/or equipment integration
• Easy access to service the coalescing filter elements
Introduction
6-4 cumminsfiltration.com
Product benefits include:
• Reduced engine oil consumption
• Reduced engine maintenance due to residual oil drip build-up
• Increased uptime
• Quick and easy service
• Reduced environmental impact and waste
• Flexibility as most of our products can be applied in either OCV or CCV mode
Optional features include:
• Crankcase ventilation heat for cold ambient conditions
• Heater options for cold ambient conditions (on select products)
• Oil drain check valves
• Crankcase Depression Regulation (CDR) valves
• Filter Minder® visual restriction gauge
• Crankcase pressure sensor
Fleetguard® crankcase ventilation systems are capable of vastly reducing the amount of contaminates either vented to the atmosphere or circulated back into the air intake for a wide variety of today’s diesel engines, keeping the turbocharger and heat exchangers clean and performing well . To maintain a vehicle’s optimal performance, and in order to operate under warranty, it is important that installation recommendations be met . If there are any questions, a Technical Assistance Specialist should be called . A list of the worldwide Customer Assistance Centers may be found on the back of this document . For further information, please visit cumminsfiltration .com .
Introduction
6-5cumminsfiltration.com
Crankcase Ventilation M
anager (CVM)
6-6 cumminsfiltration.com
Introduction Crankcase Ventilation Manager (CVM)
Advanced Oil Separation : Stratapore™ CV
Varied filter sizes are arranged in an effective
gradient structure Glass Reinforced Nylon ShellProvides light-weight heat resistance and containment of the oil coalescing element (bottom access also available)
Crankcase Depression Regulation (CDR) ValveProtects the crankcase from excess vacuum in a closed configuration
Integral Aluminum Mounting Bracket
With 6" x 2 .5" (154 mm x 65 mm)
bolt pattern
Clean Blow-by Gas Outlet
Returns clean blow-by to the atmosphere, or engine air intake
(variable orientation)
Oil Drain PortRoutes separated oil back to the oil sump (0 .4 " (10 mm) hose port)Optional Heating
SystemAvailable for use in cold environments
Blow-by Gas Inlet
Crankcase Pressure Sensor (FCI/Apex®
3-Pin Connector)Optimizes service
intervals
Threaded CollarAllows easy removal of
the reusable shell
Superior Crankcase Ventilation Management• Highest oil and particle removal efficiency available
• High efficiency to meet emissions regulation compliance
• Long service intervals and reliability of the engine air handling components
• Maintains superior saturated oil removal efficiency for the droplet (aerosol) sizes that comprise blow-by gases
6-7cumminsfiltration.com
Crankcase Ventilation Manager (CVM) CVM280B
Outlet
Inlet
Drain
Pressure Sensor
Specification CVM280B
Height Overall 11.46" (290.9 mm)
Depth Overall 7.92" (201 mm)
Width Overall 6.97" (177 mm)
Nominal Flow 3.53 ft3/min (100 L/min)
Efficiency at Nominal Flow (Dry) 99.5 %
Restriction at Nominal Flow (Dry) 1.97" H2O (0.49 kPa)
Restriction at Nominal Flow (Saturated) 5.51" H2O (1.37 kPa))
Maximum Flow 9.89 ft3/min (280 L/min)
Restriction at Max Flow (Dry) 8.11" H2O (2.02 kPa)
Restriction at Max Flow (Saturated) 15.87" H2O (3.95 kPa)
Specifications
6-8 cumminsfiltration.com
CVM280B Crankcase Ventilation Manager (CVM)
PartNo .
IncludedDescription
A 1 Head
B 1 *O-Ring
C 1 *Element
D 1 Collar
E 1 Shell
* Parts included in Service Kit #CV52053 .
Parts List
A
B
C
E
D
6-9cumminsfiltration.com
Crankcase Ventilation Manager (CVM) CVM280B
Part Number Description Outlet Orientations
CV52008 CVM with Outlet at 3 O'Clock
3:00 12:00 9:00
CV52034 CVM with Outlet at 12 O'Clock
CV52015 CVM with Outlet at 9 O'Clock (as shown below)
CV52053 Service Kit (includes O-Ring and Element)
Ordering Information
Mounting/Dimensions
All dimensions are in inches (millimeters)
6.49(164.85)
6.97 (177)
∅ 4.90 (124.56)
11.45(290.9)
Outlet: 1.00 OD (25.4 mm) hose port
Outlet:1.00 OD
(25.4 mm) hose port
Outlet:1.00 OD
(25.4 mm) hose port
Inlet: 1.00 OD (25.4 mm) hose port
Inlet: 1.00 OD (25.4 mm) hose port
Drain: 0.39(10 mm) hose port
Drain: 0.39(10 mm) hose port
1.97 (50)
3.20(81.25)
2.01 (51)3.31 (84)
7.91(201)
6.06 (154)∅ 0.47(11.8)
(4X)
2.56(65)1.73 (44)
6.68 169.65)
5.27 (133.95)Service Envelope
Fractional Efficiency Flow vs Restriction (Clean Element)Performance
Particle Size (µm)
95
96
97
98
99
100
0.1 0.3 0.5 0.7 0.9 1.1 1.3
Effi
cien
cy (
%)
0 2 4 6 8 100
2
4
6
8
10
Flow Rate (ft3/min)
Res
tric
tion
(inch
H20
)
0.0
0.5
1.0
1.5
2.0
2.5
Flow Rate (L/min)R
estr
ictio
n (k
Pa)
0 10050 150 200 250 300
6-10 cumminsfiltration.com
CVM280T Crankcase Ventilation Manager (CVM)
OutletInlet
Drain
PressureSensor
Specification CVM280T
Height Overall 11.71" (297.37 mm)
Depth Overall 7.91" (201 mm)
Width Overall 8" (203.2 mm)
Nominal Flow 3.53 ft3/min (100 L/min)
Efficiency at Nominal Flow (Dry) 99.5 %
Restriction at Nominal Flow (Dry) 1.97" H2O (0.49 kPa)
Restriction at Nominal Flow (Saturated) 5.51" H2O (1.37 kPa))
Maximum Flow 9.89 ft3/min (280 L/min)
Restriction at Max Flow (Dry) 8.11" H2O (2.02 kPa)
Restriction at Max Flow (Saturated) 15.87" H2O (3.95 kPa)
Specifications
6-11cumminsfiltration.com
Crankcase Ventilation Manager (CVM) CVM280T
PartNo .
IncludedDescription
A 1 Shell
B 1 Collar
C 1 *O-Ring
D 1 *Element
E 1 Head
* Parts included in Service Kit #CV52053 .
Parts List
A
B
C
E
D
6-12 cumminsfiltration.com
CVM280T Crankcase Ventilation Manager (CVM)
Part Number Description Outlet Orientations
CV52019 CVM with Outlet at 3 O'Clock
3:00 6:00 9:00
CV52021 CVM with Outlet at 6 O'Clock (as shown below)
CV52023 CVM with Outlet at 9 O'Clock
CV52053 Service Kit (includes O-Ring and Element)
Ordering Information
Mounting/Dimensions
All dimensions are in inches (millimeters)
11.71(297.37)
6.06 (154)
∅ 4.90 (124.56)
6.06 (154)∅ 0.47(11.8)
(4X)
2.56(65)
7.15(181.62)
1.73 (44)
5.20(131.94)Service
Envelope
3.31(84) 5.04
(128)
8.0 (203.2)6.97 (177)
∅ 6.29(159.69)
1.97(50)
7.91(201)
Outlet:1.00 OD
(25.4 mm) hose port
Inlet: 1.00 OD (25.4 mm) hose port
Drain: 0.39(10 mm) hose port
3.31(84)
6.49(164.85)
Fractional Efficiency Flow vs Restriction (Clean Element)Performance
Particle Size (µm)
95
96
97
98
99
100
0.1 0.3 0.5 0.7 0.9 1.1 1.3
Effi
cien
cy (
%)
0 2 4 6 8 100
2
4
6
8
10
Flow Rate (ft3/min)
Res
tric
tion
(inch
H20
)
0.0
0.5
1.0
1.5
2.0
2.5
Flow Rate (L/min)
Res
tric
tion
(kP
a)
0 10050 150 200 250 300
6-13cumminsfiltration.com
Crankcase Ventilation Manager (CVM) CVM424B
Outlet
Inlet
Drain
Pressure Sensor
Specification CVM424B
Height Overall 15.39" (391 mm)
Depth Overall 7.91" (201 mm)
Width Overall 6.97" (177 mm)
Nominal Flow 5.30 ft3/min (150 L/min)
Efficiency at Nominal Flow (Dry) 99.9 %
Restriction at Nominal Flow (Dry) 2.28" H2O (0.57 kPa)
Restriction at Nominal Flow (Saturated) 4.92" H2O (1.23 kPa)
Maximum Flow 14.97 ft3/min (424 L/min)
Restriction at Max Flow (Dry) 12.17" H2O (3.03 kPa)
Restriction at Max Flow (Saturated) 17.56" H2O (4.37 kPa)
Specifications
6-14 cumminsfiltration.com
CVM424B Crankcase Ventilation Manager (CVM)
A
B
C
E
D
PartNo .
IncludedDescription
A 1 Shell
B 1 Collar
C 1 *O-Ring
D 1 *Element
E 1 Head
* Parts included in Service Kit #CV52052 .
Parts List
6-15cumminsfiltration.com
Crankcase Ventilation Manager (CVM) CVM424B
Part Number Description Outlet Orientations
CV52016 CVM with Outlet at 3 O'Clock
3:00 12:00 9:00
CV52006 CVM with Outlet at 12 O'Clock (as shown below)
CV52009 CVM with Outlet at 9 O'Clock
CV52052 Service Kit (includes O-Ring and Element)
Ordering Information
Mounting/Dimensions
Fractional Efficiency Flow vs Restriction (Clean Element)Performance
Particle Size (µm)
95
96
97
98
99
100
0.1 0.3 0.5 0.7 0.9 1.1 1.3
Effi
cien
cy (
%)
0 3 6 9 12 150246
1012
8
14
Flow Rate (ft3/min)
Res
tric
tion
(inch
H20
)
0.00.51.01.52.0
3.5
2.53.0
Flow Rate (L/min)R
estr
ictio
n (k
Pa)
0 100 200 300 400
All dimensions are in inches (millimeters)
15.39(391)
10.46(265.8)
3.31(84)
6.49(164.85)
6.06 (154)
6.97 (177)
∅ 4.90 (124.56)
1.97 (50)
2.01 (51)7.91(201)
6.06 (154)∅ 0.47(11.8)
(4X)
2.56 (65)1.73 (44)
5.27 (133.95)Service Envelope
Drain: 0.39(10 mm) hose port
Drain: 0.39(10 mm) hose port
Inlet: 1.00 OD (25.4 mm)
hose port
Outlet: 1.00 OD (25.4 mm)
hose port
6-16 cumminsfiltration.com
CVM424T Crankcase Ventilation Manager (CVM)
Outlet
Inlet
Drain
PressureSensor
Specification CVM424T
Height Overall 15.50" (393.47 mm)
Depth Overall 7.92" (201 mm)
Width Overall 8" (203.2 mm)
Nominal Flow 5.30 ft3/min (150 L/min)
Efficiency at Nominal Flow (Dry) 99.9 %
Restriction at Nominal Flow (Dry) 2.28" H2O (0.57 kPa)
Restriction at Nominal Flow (Saturated) 4.92" H2O (1.23 kPa)
Maximum Flow 14.97 ft3/min (424 L/min)
Restriction at Max Flow (Dry) 12.17" H2O (3.03 kPa)
Restriction at Max Flow (Saturated) 17.56" H2O (4.37 kPa)
Specifications
6-17cumminsfiltration.com
Crankcase Ventilation Manager (CVM) CVM424T
A
B
C
E
D
PartNo .
IncludedDescription
A 1 Shell
B 1 Collar
C 1 *O-Ring
D 1 *Element
E 1 Head
* Parts included in Service Kit #CV52052 .
Parts List
6-18 cumminsfiltration.com
CVM424T Crankcase Ventilation Manager (CVM)
Part Number Description Outlet Orientations
CV52007 CVM with Outlet at 3 O'Clock
3:00 6:00 9:00
CV52017 CVM with Outlet at 12 O'Clock
CV52028 CVM with Outlet at 9 O'Clock (as shown below)
CV52052 Service Kit (includes O-Ring and Element)
Ordering Information
Mounting/Dimensions
Fractional Efficiency Flow vs Restriction (Clean Element)Performance
Particle Size (µm)
95
96
97
98
99
100
0.1 0.3 0.5 0.7 0.9 1.1 1.3
Effi
cien
cy (
%)
0 3 6 9 12 150246
1012
8
14
Flow Rate (ft3/min)
Res
tric
tion
(inch
H20
)
0.00.51.01.52.0
3.5
2.53.0
Flow Rate (L/min)
Res
tric
tion
(kP
a)
0 100 200 300 400
All dimensions are in inches (millimeters)
15.39(393.47)
0.48(12.3)
3.31 (84)
6.49(164.85)
6.97 (177)8.00 (203.2)
∅ 6.29(159.69)
1.97(50)
3.20(81.25)
7.91(201)
10.93(277.7)
∅ 4.90 (124.56)
6.06 (154)
6.06 (154)
∅ 0.47(11.8)(4X)
2.56(65)
9.20(233.7)
8.98 (228.04)Service Envelope
Drain: 0.39(10 mm)hose portInlet: 1.00 OD (25.4 mm)hose port
Inlet: 1.00 OD (25.4 mm) hose port
Outlet:1.00 OD
(25.4 mm) hose port
Outlet:1.00 OD (25.4 mm) hose port
1.73 (44)
6-19cumminsfiltration.com
CV51118
Specification CV51118
Height Overall 13.7" (347.1 mm)
Depth Overall 3.4" (87.3 mm)
Width, Max 11.5" (291.0 mm)
Weight (Dry) 4.63 lbs (2.1 kg)
Nominal Flow Rate 6 ft3/min (170 L/min)
Restriction at Nominal Flow 0.3 kPa (1.2 in H2O)
Rated Flow Rate 12 ft3/min (340 L/min)
In
Out
Drain
Note: US EPA verification pending .
Specifications
Crankcase Ventilation Filter
6-20 cumminsfiltration.com
A
C
C
D
BA
Bolts
Cover
Base
ServiceElement
PartNo .
IncludedDescription
A 1 Coalescer Assembly (includes Bolts, Cover, Service Element and Base)
B 1 CDR Valve
C 1 CDR Valve Mounting Bracket
D 1 1/2" to 3/8" Drain Line with Check Valve
Parts List
CV51118 Crankcase Ventilation Filter
6-21cumminsfiltration.com
.9
.8
.7
.6
.5
.4
.3
.2
Res
tric
tion
(kP
a)
150 250
5 6 7 8 9 10 11Flow (ft3/min)
Flow (L/min)
12
200 300100
99
98
97
96
95
Effi
cien
cy (
%)
150 250
5 6 7 8 9 10 11Flow (ft3/min)
Flow (L/min)
12
200 3003.5
3.0
2.5
2.0
1.5
1.0 Res
tric
tion
(in H
2O)
Part Number Description
CV51118 Crankcase Ventilation Kit (includes CCV Breather, CDR Valve, CDR Mounting Bracket, and Drain Line)
CV50601 Service Element
Filter Restriction vs Flow Filter Efficiency vs FlowPerformance
Mounting/Dimensions
Ordering Information
Crankcase Ventilation Filter CV51118
6-22 cumminsfiltration.com
Notes
6-23cumminsfiltration.com
Specification 93194A 93192A
Diameter 8.6" (218.4 mm) 8.6" (218.4 mm)
Length 30.2" (767.1 mm) 38.1 (967.7 mm)
Inlet/Outlet Tube OD 1.75" (44.5 mm) 2.25" (57.2 mm)
Max. Crankcase Emission Flow Rate with Clean Element
15 SCFM (0.43 m3/min) 25 SCFM (0.71 m3/min)
OutletInlet
ManometerConnection
Drain
Specifications
93194A • 93192ARecirculators
6-24 cumminsfiltration.com
A
DE
BC
PartNo .
IncludedDescription
A 1 Recirculator
B 1 Filter Element
C 1 Cover Gasket
D 1 Grommet
E 1 Hex Nut
Parts List
93194A • 93192A Recirculators
6-25cumminsfiltration.com
1.130.630.13 1.63 2.13 2.63
40200 60 80 100
93194A
Initial Max. Pressure
Res
tric
tion
(inch
H2O
)
Res
tric
tion
(kP
a)
Flow Rate (m3/min)
3
2
1
0
3.0
2.5
2.0
1.5
1.0
0.5
0
Flow Rate (SCFM)
Part Number Description
93194A Recirculator Unit
88365A Service Element
Q58403 Cover Gasket
Q58521 Grommet
Q53714 Hex Nut
30.2 (767.1)
Outlet
Inlet8.6
(218.4)1.75
(44.5)OD
1.75(44.5)OD
All dimensions are in inches (millimeters)
Filter Restriction vs FlowPerformance
Mounting/Dimensions
Ordering Information
Recirculators 93194A
6-26 cumminsfiltration.com
1.130.630.13 1.63 2.13 2.63
40200 60 80 100
93192A
Initial Max. Pressure
Res
tric
tion
(inch
H2O
)
Res
tric
tion
(kP
a)
Flow Rate (m3/min)
3
2
1
0
3.0
2.5
2.0
1.5
1.0
0.5
0
Flow Rate (SCFM)
Part Number Description
93192A Recirculator
88465A Service Element
Q58403 Cover Gasket
Q58521 Grommet
Q53714 Hex Nut
38.1 (967.7)
Outlet
Inlet8.6
(218.4)2.25
(57.2)OD
2.25(57.2)OD
All dimensions are in inches (millimeters)
Filter Restriction vs FlowPerformance
Mounting/Dimensions
Ordering Information
93192A Recirculators
6-27cumminsfiltration.com
Vent Outlet
Inlet FromEngine
Oil DrainBack toEngine
Specification CV50111
Height Overall (Breather) 13.7" (150 mm)
Depth Overall (Breather) 3.4" (113.3 mm)
Weight (Dry) (Kit) 9.9 lbs (4.5 kg)
Max. Flow 6 ft3/min (169.9 L/min)
Min. Flow 3 ft3/min (85.0 L/min)
Max. Restriction 11-12 in H2O (280-305 mm H2O)
Specifications
CV50111Crankcase Ventilation Breathers
6-28 cumminsfiltration.com
PartNo .
IncludedDescription
A 1 Mounting Bracket
B 1 Breather Assembly and Mounting Hardware
C 1 Vent Hose
D 1 Vent Hose Connector and Clamps
E 1 Vent Hose Extender
F 1 Cylinder Block Insert Fittings and Coupler
G 1 Drain Hose Assembly
H 1 Breather Hose Connections and Clamps
I 1 Inlet Hose Assembly
J 4 Inlet Hose Connections and Clamps
A
B
C
D
E
G
H
I
J1 J2
J3 J4
F
Parts List
CV50111 Crankcase Ventilation Breathers
6-29cumminsfiltration.com
Part Number Description
CV50111 Single Crankcase Ventilation Breather Kit (includes parts listed on previous page)
All dimensions are in inches (millimeters)
0.34(8.79)Dia.
3.15(80.0)
5.90(150.0)
0.40(10.1)
0.79(20.1)
0.79(20.0)
4.46(113.3)
3.12(79.3)
1.83(46.5)
4.19(106.3)
Dia.
0.37(9.52)
Bushing
1.02(26.0)Dia.
Flow Direction
Flow Direction
2.76(70.0)
3.62(92.0)
2 Places
3.62(92.0)
2 Places
0.5(12.70)
Dia.1.00(25.40)Dia.
Crankcase Ventilation Breathers CV50111
Mounting/Dimensions
Ordering Information
6-30 cumminsfiltration.com
Vent OutletVent Outlet
Inlet FromEngine
Oil DrainBack toEngine
Oil DrainBack toEngine
Specification CV50202
Height Overall (Breather) 13.7" (150 mm)
Depth Overall (Breather) 7.1" (181.2 mm)
Weight (Dry) (Kit) 12.1 lbs (5.5 kg)
Max. Flow 14 ft3/min (396.4 L/min)
Min. Flow 7 ft3/min (198.2 L/min)
Max. Restriction 11-12 in H2O (280-305 mm H2O)
Specifications
CV50202 Crankcase Ventilation Breathers
6-31cumminsfiltration.com
Crankcase Ventilation Breathers CV50202
PartNo .
IncludedDescription
A 1 Breather and Bracket Assembly
B 1 Drain Fitting
C 1 Drain Hose Assembly
D 1 Vent Hose Assembly
E 1 Breather Inlet Hose Assembly
F 1 Reducer Fitting and Clamps
A
B
C
E
F
D
Parts List
6-32 cumminsfiltration.com
Part Number Description
CV50202 Dual Crankcase Ventilation Breather Kit (includes parts listed on previous page)
Mounting/Dimensions
Ordering Information
7.13(181.2)
4.46(113.3)
2.23(56.6)
2.23(56.6)
4.31(109.4)
Dia.
3.62(92.0)
3.15(80.0)
5.90(150.0)
2.76(70.0)
5.31(135.0)
0.34 (8.79)Dia. 4 Places
3.62(92.0)
0.5(12.70)
Dia.3.57
(90.6)3.57
(90.6)1.31
(33.3)
2.62(66.55)
1.00 (25.40)Dia. 3 Places
1.31(33.3)
All dimensions are in inches (millimeters)
CV50202 Crankcase Ventilation Breathers