9
Operating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4. ACCESSORIES 5. MAINTENANCE AND CLEANING & FAULTY RUNNING 6. WARRANTY YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600 TEL: 82-31-429-7471/2 FAX:82-31-429-7470 E-MAIL:[email protected] Www.finepcr.com Operating Manual Operating Manual Compact Rocker

Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

Embed Size (px)

Citation preview

Page 1: Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

Operatin

g M

an

ual

Operatin

g M

an

ual Cr95

cr100cr300cr300t

1. PRODUCTS DESCRIPTION2. USER CONSIDERATION3. USER OPERATION 4. ACCESSORIES5. MAINTENANCE AND CLEANING & FAULTY RUNNING6. WARRANTY

YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600

TEL: 82-31-429-7471/2 FAX:82-31-429-7470 E-MAIL:[email protected]

Operating Manual Operating Manual

Compact Rocker

Page 2: Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

Cr300t

Cr300

Rockers (W300 X D300mm platform)

Tachometer

Variable wide speed and powerful DC motor provide the gentle motion.

Safe and durable for use at high and low temperature.

All of the rocking platform's moving parts are fitted with

ball bearings for quiet operation and years of trouble free use.

Suitable for continuous operation.

Durable construction enough to load heavy objects.

(CR95 - 5kg, CR100 - 7kg, CR300,CR300t - 10kg)

Cr100

Cr95

Rockers (W290 X D200 platform)

1

PR

OD

UC

T D

ES

CR

IPT

ION

Introduction

* Durable for high temperature ( up to 80 )* Inside incubator

* Variable speed control

* Variable speed control

* Variable speed control* Tachometer - speed display with digital)

Page 3: Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

Specification

Description

2

SpeedTIME/min

POWER

FINEMOULD PRECISION IND.CO.

FINEMOULD PRECISION IND.CO.

Compact rocKER

Cr300

Platform

Platform

Non-slip pad

Speed controller

Speed controller

TimerRubber foot

Rubber footPower on/off switch

Other RockersRocker-CR95

±7˚

FINEMOULD PRECISION IND.CO.

compact ROCKER Speed

compact ROCKER

Cr95POWER

OFF1

2

3

4

56

Power on/off switch

Silicon pad

±9˚

PR

OD

UC

T D

ES

CR

IPT

ION

Model

Tilt Angle

Speed range

Speed Timer

Dimensions(mm)

Weight

Wattage

Power

Motor

Temp. Resist

Load able Weight

Platform(mm)

Cr100 Cr300 Cr300tCr95

Select control 6steps(12~55 rpm) Variable 0 ~ 70 rpm

DC Warm Geard Motor

- 180min

Lower than 80˚C(Dry air) Lower than 65˚C (Dry air)

10kg 7kg5kg

8.2kg 6.5kg6kg

W290 x D210 x H167 W300 x D300 x H232

W290 x D200 W300 x D300

18W 35W

Free voltage(AC100 ~ 240V)

AC100V / 50/60HzAC110V / 50/60HzAC220V / 50/60HzAC230V / 50/60Hz (CE cert) AC240V / 50/60Hz

Page 4: Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

V011

110V

220V

Check if the voltage indicated on appliance corresponds to the local mains voltage before you connect the appliance.

Unplug the appliance : - If problems occur during rocking process.- Before you start cleaning the unit.- Never use the appliance if the plug, the cord or the appliance itself is damaged

Be careful not to drop any chemical liquid and wateron the instrument to prolong the life of the instrumentand protect electronic shock.For example, PEG could be reason for peeling off the paint on the surface.

Environmental conditions

- Indoor use.- Environment temperature 5℃ to 40℃.- Maximum relative humidity 80% for temperatures up to 31℃ decreasing linearly to 50% relative humidity at 40℃.- Mains supply voltage fluctuations not to exceed 10% of the nominal voltage.- Other supply voltage fluctuations as stated by the manufacturer. - Transient overvoltages according to installation categories.

3

SpeedTIME/min

POWER

FINEMOULD PRECISION IND.CO.

FINEMOULD PRECISION IND.CO.

Compact Rocker

cr300t39

User consideration

US

ER

CO

NS

IDE

RA

TIO

N

Page 5: Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

WA

RR

AN

TY

1

2

3

5

This section summarizes operation procedures for FINEPCR`s rockers controlling the rocking movement.

Check the name rating plate for confirming the correct voltage, then plug the power cord into thereceptacle on back of the instrument.

Plug the power cord into the wall receptacle.

Turn the power ON/OFF control buttonto position ON.

4

4

4

POWER

ON

OFF

30

60

90

120

150

180

TIME/min

POWER

ON

OFF

30

60

90

120

150

180

TIME/min

I

O

TIME/min

OFF

30

60

ON

90

120

150

180

Speed

Speed

1

1

2

2

3

3

4

4

5

5

6

6

7

8

9

OFF

OFF

(If the indicating lamp in the switch is not working, Please check whether the main electric socket is connected firmly with the main body or the timer was pointed at the ON.)

Control the working time as your request.

Control the setting rotating speed.CR100, CR300, Cr300t (0 ~ 50rpm)

CR95

Others

Control the setting rotating speed.CR95 (4, 8, 12,16, 28, 32rpm)

User operation

US

ER

OP

ER

AT

ION

Page 6: Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

Cr95

Accessories

53

Cr100

Cr300 / Cr300t

AC

CE

SS

OR

IES

TY-95 (Second Platform)DP95 (Dimpled Pad)

TY-100 (Second Platform)DP100 (Dimpled Pad)

TY-300 (Second Platform)DP300 (Dimpled Pad)

* Elastic ties for holding flasks and tubes easily.

UP400 (Upper Platform) 400 X 400 mm

Page 7: Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

The method of the Tray combination

1. Insert the 4 Screws in the corner holes of the Platform.

2. Tighten up the 4 legs using the above Screws.

3. Unscrew the Mount knobs from the Legs and insert tighten up the 4 Mount knobs.

Note ; When you use this Rocker as a second platform, the Mount Knobs are always tightened on the Leg threads in order not to lose.

Screw

Second Platform

Leg

Thread

Platform

Mount Knob

The platform could be used as a shelfon a desk.

6

User operation

US

ER

OP

ER

AT

ION

Page 8: Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

Always unplug the instrument before you start cleaning it.

Never immerse the appliance in water.

7

Never use the instrument if the plug, the cord or the instrument itself is damaged.

The equipment is maintenance-free.

Clean the surfaces of the rocker

. Water containing a surfactant detergent additive.

. Isopropylalcohol

. Turn the power ON/OFF control button to position OFF

. Pull the mains plug off

. Clean the surfaces of the Rocker

1. After turning on the power switch, The units does not working. Please, Checking the electronic fuse.

Be able to find a fuse box on the back of the instrument, After departing the fuse box, It could be very easy to change the fuse with new one.

If the equipment have other defects, It should be informed to an authorised servicing agent.

spare fuse

remove used fuse

Maintenance and Cleaning

Faulty running

MA

INT

EN

AN

CE

AN

D C

LE

AN

ING

& F

AU

LTY

RU

NN

ING

Page 9: Cr95 cr100 cr300t Operating Manual Operating · PDF fileOperating Manual Operating Manual Cr95 cr100 cr300 cr300t 1. PRODUCTS DESCRIPTION 2. USER CONSIDERATION 3. USER OPERATION 4

1 YEAR WARRANTY

Limited Warranty :

This equipment has been tested all the functions and parts for proper operation before shipment.Please read this manual carefully. If you have any questions or problems, check with your dealer or write us direct. This equipment is warranted for a period of 1years from date of purchase against defects in workmanship and material only. If a system component should ever fail to work perfectly, It can be repaired or replaced by our after-sales service without difficulty.

Model#:

Serial# :

Date Purchased :

Dealer Name :

City and Country :

YANG-CHUN P.O BOX 100, SEOUL, KOREA. 158-600

TEL: 82-31-429-7471/2 FAX:82-31-429-7470 E-MAIL:[email protected]

WA

RR

AN

TY

Warranty