Date Application Deemed Complete October 10, 2017 Date Extension Letter Sent N/A End of 60-Day Decision Period December 9, 2017 End of 120-Day Decision Period N/A LAND USE APPLICATION SUMMARY Property Location: 1201 West Broadway Project Name: 1201 West Broadway Tower Prepared By: Lindsey Wallace, City Planner, (612) 673-2653 Applicant: Eco-Site, LLC Project Contact: Kristian Olson Request: To allow a telecommunications tower. Required Applications: Conditional Use Permit To allow a telecommunications tower in the OR2/High Density Office Residence District. SITE DATA Existing Zoning OR2/High Density Office Residence District PO/Pedestrian Oriented Overlay District Lot Area 103,731 square feet / 2.38 acres Ward(s) 5 Neighborhood(s) Near North Neighborhood; adjacent to Jordan Neighborhood Designated Future Land Use Urban Neighborhood Land Use Features The property has street frontage on West Broadway, a Commercial Corridor and Fremont Avenue N, a Community Corridor. Small Area Plan(s) West Broadway Alive (2008) CPED STAFF REPORT Prepared for the City Planning Commission CPC Agenda Item #5 November 13, 2017 PLAN5232

CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Date Application Deemed Complete October 10, 2017 Date Extension Letter Sent N/A

End of 60-Day Decision Period December 9, 2017 End of 120-Day Decision Period

N/A

LAND USE APPLICATION SUMMARY

Property Location: 1201 West Broadway

Project Name: 1201 West Broadway Tower

Prepared By: Lindsey Wallace, City Planner, (612) 673-2653

Applicant: Eco-Site, LLC

Project Contact: Kristian Olson

Request: To allow a telecommunications tower.

Required Applications:

Conditional Use Permit

To allow a telecommunications tower in the OR2/High Density Office Residence District.

SITE DATA

Existing Zoning OR2/High Density Office Residence District PO/Pedestrian Oriented Overlay District

Lot Area 103,731 square feet / 2.38 acres

Ward(s) 5

Neighborhood(s) Near North Neighborhood; adjacent to Jordan Neighborhood

Designated Future Land Use

Urban Neighborhood

Land Use Features The property has street frontage on West Broadway, a Commercial Corridor and Fremont Avenue N, a Community Corridor.

Small Area Plan(s) West Broadway Alive (2008)

CPED STAFF REPORT Prepared for the City Planning Commission

CPC Agenda Item #5 November 13, 2017

PLAN5232

Page 2: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Department of Community Planning and Economic Development PLAN5232

2

BACKGROUND

SITE DESCRIPTION AND PRESENT USE. The subject site is 103,731 square feet and consists of an existing 46,500 square foot building and several surface parking lots with a total of 150 spaces. The building on-site is occupied by Shiloh Temple International Ministries and is a place of assembly. In addition to a place of assembly, a child care center operates out of the building during the week.

SURROUNDING PROPERTIES AND NEIGHBORHOOD. The property is located at the intersection of West Broadway, a Commercial Corridor, and Fremont Avenue N, a Community Corridor. Neighboring properties along West Broadway include a mix of commercial, residential, and institutional uses. Moving away from West Broadway, there is a mix of residential densities including single-family homes, duplexes, and multiple-family apartment buildings with interspersed institutional uses. Directly south of the project site is North High School’s football field which occupies more than one city block.

PROJECT DESCRIPTION. The applicant is proposing to construct a 105-foot telecommunications tower with a 4-foot lightning rod directly to the south of the existing building on site. The tower would occupy a 58 foot by 34 foot leased area that would house the telecommunications tower and base unit. The leased area would include a 1,399 square foot (53.8 feet by 26 feet) fenced area surrounded by landscaping and screening. The enclosure includes enough space to accommodate the equipment for at least three communications carriers. The proposed tower compound is bordered by the church building to the north, an outdoor children’s play area to the east, the existing parking lot to the south, and an access drive and utilities to the west. The tower is proposed to be a monopole design.

The applicant has proposed to screen the tower enclosure and mechanical equipment with twenty-five evergreen shrubs, which will reach 6 feet in height at maturity. The construction of the tower would require the removal of a mature deciduous tree on site. The applicant has proposed two canopy trees to be planted along Fremont Avenue N to mitigate the removal of the mature tree.

RELATED APPROVALS.

Planning Case # Application(s) Description Action

BZZ-1608 Parking variances

Variances to reduce the off-street parking requirement and to reduce yards in order to allow for existing parking spaces.

Approved by the Zoning Board of Adjustment on April 1, 2004.

PUBLIC COMMENTS. No public comments have been received as of the printing of this staff report. Any correspondence received prior to the public meeting will be forwarded on to the Planning Commission for consideration.

ANALYSIS

CONDITIONAL USE PERMIT The Department of Community Planning and Economic Development has analyzed the application to allow a telecommunications tower based on the following findings:

1. The establishment, maintenance or operation of the conditional use will not be detrimental to or endanger the public health, safety, comfort or general welfare.

The establishment, maintenance and operation of the conditional use will not be detrimental to or endanger the public health, safety, comfort or general welfare. The telecommunications tower will be in

Page 3: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Department of Community Planning and Economic Development PLAN5232

3

compliance with local, state and federal laws as well as standard regulations set forth by the FCC and OSHA. The site will be secured with a locked and gated security fence. The telecommunications tower is proposed to be constructed immediately adjacent to the existing church building and would require slightly relocating children’s play equipment in an adjacent outdoor play area. Due to the proximity of the tower to the church building and play area, staff is recommending a condition of approval that applicant shall submit a letter from a licensed engineer stating that the tower has the structural integrity to withstand typical wind loads and inclement weather.

The construction of the telecommunications tower would require removing the only mature canopy tree on site. The applicant has proposed screening and landscaping for the base of the tower and has proposed planting two canopy trees on the site to mitigate the impact of the tree removal. Staff recommends a condition of approval that would require the applicant to plant a total of three canopy trees of 3” caliper size on the site along Fremont Avenue N. The addition of these three trees would mitigate the impact of removing a mature canopy tree and would partially screen the tower from West Broadway and neighboring uses.

2. The conditional use will not be injurious to the use and enjoyment of other property in the vicinity and will not impede the normal and orderly development and improvement of surrounding property for uses permitted in the district.

The conditional use will not be injurious to any existing or proposed uses or enjoyment in the vicinity, nor will it impede the development and/or improvement of surrounding properties. The entire facility will be confined to a small area located behind the existing church building. The tower will not be located within any required setbacks. The proposed tower will have the capacity to support three communications carriers.

3. Adequate utilities, access roads, drainage, necessary facilities or other measures, have been or will be provided.

Adequate utilities, access roads, drainage, necessary facilities or other measures have already been provided to the site. The proposed tower will not require additional utilities beyond what is already in place.

4. Adequate measures have been or will be taken to minimize traffic congestion in the public streets.

Staff finds that the proposed communication tower will not impact the amount of traffic coming to and from the site. The applicant has indicated that the proposed telecommunications tower will be inspected for purposes of routine maintenance only, approximately once every one to three months.

This site received variances for parking in 2004 when Shiloh Temple International Ministries first located in the building. Since that time, the minimum requirement for off-street parking for places of assembly has been reduced from 20% to 10% of the capacity of persons in the main auditorium and any rooms which can be added to the main auditorium by opening doors or windows to obtain audio or video unity. The main auditorium for Shiloh Temple is approximately 15,715 square feet. The building code defines capacity for a place of assembly as 15 square feet per person. The capacity of the auditorium would therefore be 1,048 persons. The parking requirement for the place of assembly is 105 parking spaces. The minimum parking requirement for a child care center is 1 space per 500 sq. ft. of gross floor area plus two drop-off spaces. The child care center on site is approximately 14,000 square feet. The parking requirement for the child care center is 28 spaces. The total parking requirement for the place of assembly and child care center uses is 133 spaces plus two drop off spaces.

The applicant has indicated that the site includes 153 parking spaces, three of which are accessible parking spaces. The proposed project would result in the removal of three parking spaces for a total of 150 spaces, which is greater than minimum off-street parking requirement of 133 spaces plus two drop off spaces.

5. The conditional use is consistent with the applicable policies of the comprehensive plan.

The proposed development would be consistent with the following policies of The Minneapolis Plan for Sustainable Growth:

Page 4: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Department of Community Planning and Economic Development PLAN5232

4

Economic Development Policy 4.3: Develop and maintain the city’s technological and information infrastructure to ensure the long-term success and competitiveness of Minneapolis in regional, national and global markets.

4.3.1 Promote the use of best available technology in upgrading communication linkages to the region and the world.

4.3.4 Electronically link schools, libraries and community centers into telecommunications and information infrastructure.

Public Services and Facilities Policy 5.6: Improve the safety and security of residents, workers, and visitors.

5.6.4 Maintain and enhance a public safety infrastructure that improves response time to police and fire calls, implements new technologies, provides operation and training opportunities and facilities, and improves communication among public safety agencies.

6. The conditional use shall, in all other respects, conform to the applicable regulations of the district in which it is located. If approved, the proposed telecommunications tower will meet the requirements of the OR2 zoning district.

In addition to the findings required for a CUP, approval of a telecommunications tower/antenna requires the applicant to submit written documentation indicating compliance with the following standards:

535.530. - Specific standards for conditional uses. All communication towers and antennas requiring a conditional use permit shall be subject to the provisions of Chapter 525, Administration and Enforcement, and the submittal requirements of section 535.510(b). In addition, the applicant shall comply with the following standards and submit written documentation indicating such compliance:

(1) Tower type. Communication towers shall be of a monopole design. The city planning commission may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations, location or the number of co-locators suggests a tower other than a monopole.

The applicant is proposing to construct a 105-foot monopole with a 4-foot lightning rod.

(2) Co-location of communication antennas. Shared use of existing communication towers shall be preferred to the construction of a new tower.

The applicant has submitted documentation indicating that there are two existing telecommunications towers within a one-mile radius. The applicant has indicated that neither of these two towers would be suitable due to being too far away from the target site. The proposed tower would include space for the co-location of two additional communications carriers.

(3) Height of freestanding towers and antennas.

a. Residence, office residence and commercial districts. The height of freestanding communication towers and antennas located in the residence, office residence and commercial districts shall not exceed seventy-five (75) feet.

The applicant has proposed to exceed the allowable height of a freestanding communication tower and has submitted statements to address finding (c) below.

b. Industrial districts. The height of freestanding communication towers and antennas located in the industrial districts shall not exceed one hundred (100) feet.

Not applicable.

c. Excess height. The city planning commission may increase the height of freestanding towers and antennas, provided that in the residence, office residence and commercial districts such increase shall not exceed the maximum height by more than fifty (50)

Page 5: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Department of Community Planning and Economic Development PLAN5232

5

percent. The applicant shall submit an inventory of existing and approved communication towers within a one (1) mile radius of the proposed site outlining opportunities for shared use as an alternative to the construction of a new tower, and shall demonstrate to the satisfaction of the city planning commission the following:

1. The proposed antenna cannot be accommodated on an existing or approved tower due to one (1) or more of the following reasons:

i. The unwillingness of the owner of the existing or approved tower to co-locate an additional antenna.

ii. The planned antenna would exceed the structural capacity of existing or approved tower.

iii. The planned antenna would cause radio frequency interference with other existing or planned equipment, which cannot reasonably be prevented.

iv. Other reasons affecting technical performance, system coverage and system capacity make it impractical to place the proposed equipment on existing or approved towers.

v. The proposed co-location on an existing or approved tower would not conform to the requirements of the zoning ordinance.

The applicant has submitted documentation indicating that the two existing towers within a one-mile radius would not be close enough in proximity to the target site to improve cell coverage.

2. The surrounding topography, structures, vegetation and other factors make a tower that complies with the district height regulations impractical.

The applicant has submitted a statement indicating that the proposed tower height of 109 feet is the minimum height that will result in coverage and capacity objectives in the area given the surrounding topography, vegetation and existing structures. The applicant has identified the height of nearby mature trees at 60 feet, the height of nearby buildings of 60 feet or taller and ground elevation changes as factors that require the additional tower height.

3. The proposed tower is designed to structurally accommodate both the applicant's antenna and at least one (1) additional user. The applicant shall submit a letter indicating the proposed tower is available for co-location with a phone number for interested parties to call.

The applicant has submitted a letter indicating the proposed tower is available for co-location for two additional communications carriers.

(4) Height of all other towers and antennas allowed by conditional use. The maximum height of all other towers and antennas shall be as approved by conditional use permit.

Not applicable.

535.540. - Development standards for all permitted and conditional communication towers, antennas and base units. In addition to the standards of sections 535.490, 535.500 and 535.530 above, all communication towers, antennas and base units shall be subject to the following standards:

(1) Encroachments and setbacks.

a. The tower site and setback shall be of adequate size to contain guyed wires, debris and the tower in the event of a collapse.

Page 6: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Department of Community Planning and Economic Development PLAN5232

6

The tower location is set back from property lines and adjacent residential dwellings but is immediately adjacent to the existing church building and an outdoor children’s play area. As a condition of approval, staff recommends replacing this requirement with the condition that the applicant must submit a letter from a licensed engineer stating that the tower will have the structural integrity to withstand inclement weather conditions.

b. Communication towers shall maintain a minimum distance from the nearest residential structure equal to twice the height of the tower. For the purposes of this article, residential structures shall also include any parking structure attached to a principal residential structure.

The submitted plans show that the nearest residential structure is located 230 feet from the proposed tower, more than twice the height of the tower.

c. No part of any communication tower, antenna, base unit, equipment, guyed wires or braces shall extend across or over any part of a public right-of-way, except communication antennas and transmission equipment mounted to city-owned light poles or traffic signal davits in public rights of way for which a valid attachment permit has been granted pursuant to Chapter 451 of the Minneapolis Code of Ordinances.

No part of the telecommunications tower or base equipment extends across or over any public right-of-way.

d. Communication towers, antennas and base units shall comply with applicable regulations as established by the Federal Aviation Administration.

The applicant has indicated that the project will be in compliance with the regulations established by the Federal Aviation Administration.

e. Communication towers, antennas and base units shall comply with the minimum yard requirements of the district in which they are located.

The rear and side yard setbacks in the OR2 District are 5+2x, where x equals the number of stories above the first floor. Since a story is defined as 14 feet, a 109-foot tower would be classified as an eight-story building. An eight-story building would require a 19-foot setback. The applicant’s leased area is located over 100 feet from both the west and east interior side property lines and over 97 feet from the rear property line.

(2) Compatibility with nearby properties. Communication towers, antennas and base units shall utilize building materials, colors and textures that are compatible with the existing principal structure and that effectively blend the tower facilities into the surrounding setting and environment to the greatest extent possible. Metal towers shall be constructed of, or treated with, corrosive resistant material. Outside of the industrial districts, unpainted, galvanized metal, or similar towers shall be prohibited, unless a self-weathering tower is determined to be more compatible with the surrounding area.

The proposed telecommunications tower will be located in the middle of a 2.38 acre property. The tower will be located to the rear of a building used as a place of assembly. Communication towers shall maintain a minimum distance from the nearest residential structure to twice the height of the tower. The height of the proposed tower is 109 feet and the nearest residential building is 230 feet to the west. To the south of the site is a large football field used by North High School. The closest residence to the south is over a full city block away from the proposed tower location. The applicant has proposed an unpainted tower constructed of galvanized steel. Outside of the industrial districts, unpainted, galvanized metal or similar towers are prohibited. Staff recommends a condition of approval that the tower be painted light blue to blend in with the sky.

(3) Screening and landscaping. A screening and landscaping plan designed to screen the base of the tower and the base unit shall be submitted. The plan shall show location, size, quantity and type of landscape materials. Landscape materials shall be capable of screening the site all year. One (1) row of evergreen shrubs or trees capable of forming a continuous hedge at least six (6) feet in

Page 7: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Department of Community Planning and Economic Development PLAN5232

7

height within two (2) years of planting shall be provided to effectively screen the base of the tower and the base unit, except for towers and antennas designed for private reception of television and radio signals and used for amateur or recreational purposes, and light poles and traffic signal davits in public rights-of-way that support communication antennas and transmission equipment. A maintenance plan for the landscape materials shall also be submitted. The city planning commission may consider the substitution of other architectural screening plans such as a decorative fence or masonry wall in lieu of planted materials.

The applicant has proposed an enclosure of 53.8 feet by 26 feet for the tower base and equipment. The enclosure would be secured by a chain link fence and screened by twenty-five evergreen shrubs, which will reach 6 feet in height at maturity, planted along the exterior of the chain link fence. Staff is recommending a condition of approval that the chain link fence be coated with vinyl to enhance its aesthetic appearance.

The construction of the tower would require the removal of the only mature deciduous tree on site. The site contains a large amount of surface parking that is nonconforming to the parking and loading landscaping and screening requirements of section 530.170 of the zoning code, specifically the requirement that in parking lots of ten spaces or more, no parking space shall be located more than fifty feet from the center of an on-site deciduous tree. The applicant has proposed two canopy trees to be planted along Fremont Avenue N to mitigate the removal of the mature tree. As noted above, staff is recommending a condition of approval to require three canopy trees, of at least 3” caliper size at the time of installation, to be planted on the site along Fremont Avenue N.

(4) Rooftop mounted towers and antennas. Rooftop mounted communication towers and antennas shall not be located on residential structures less than fifty (50) feet in height, except for towers and antennas designed for private reception of television and radio signals and used for amateur or recreational purposes.

Not applicable.

(5) Façade mounted antennas.

a. Mounted on freestanding towers and poles. A façade mounted antenna shall not extend above the façade of the tower or pole on which it is mounted, but otherwise may project outward beyond such façade.

The proposed antennas will not project above the façade of the tower.

b. Mounted on city-owned light poles or traffic signal davits in public rights of way. A façade mounted antenna on an existing city-owned light pole or traffic signal davit shall comply with the standards of Chapter 451 of the Minneapolis Code of Ordinances. Such antennas and transmission equipment shall be painted to match the structure to which they are mounted and shall be designed to minimize the visibility of cables and other appurtenances.

Not applicable.

c. Mounted on all other structures. A façade mounted antenna shall be mounted flush against the structure on which it is mounted and shall not extend beyond the façade of such structure, except that antennas designed for private reception of television and radio signals, used for amateur or recreational purposes, may extend above the façade of the structure.

Not applicable.

(6) Base units. Base units shall not exceed five hundred (500) square feet of gross floor area. The city may require as a condition of approval that base units be located underground.

Page 8: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Department of Community Planning and Economic Development PLAN5232

8

According to the applicant, the base unit will occupy an area that measures approximately 150 square feet. The base unit will be located within the fenced enclosure that is proposed to be screened by evergreen shrubs that will reach 6 feet in height at maturity.

(7) Security. All sites shall be reasonably protected against unauthorized climbing. The bottom of the tower, measured from ground level to twelve (12) feet above ground level, shall be designed in a manner to discourage unauthorized climbing.

The applicant has indicated that the security fence will be locked and secured at all times. Climbing pegs will not be installed as part of this project.

(8) Signage. Advertising or identification of any kind on towers, antennas and base units shall be prohibited, except for applicable warning and equipment information signage required by the manufacturer or by federal, state or local regulations.

The proposed tower would not include any signage besides the applicable warning and cautionary signage required by the Federal Communications Commission.

(9) Lighting. Communication towers and antennas shall not be illuminated by artificial means, except when mounted on an existing light pole or where the illumination is specifically required by the Federal Aviation Administration or other federal, state or local regulations.

According to the applicant, there will be no lights attached to the telecommunications tower unless required by the Federal Aviation Administration.

(10) Heritage Preservation Ordinance compliance. Communication towers and antennas proposed for any locally designated historic structures or locally designated historic districts shall be subject to all requirements of the city's Heritage Preservation Ordinance.

The State Historic Preservation Offices (SHPO) has evaluated this site. In a letter dated September 25, 2017, Sarah Beimers, Manager of Government Programs and Compliance for SHPO, indicated that no historic properties are located within the area of potential effect for direct effects. SHPO identified three historic properties are located within the area of potential effects for indirect visual effects: Minneapolis Public Library: North Branch, Plymouth Masonic Lodge and the John Lohmar House. Overall, SHPO determined that this project will have no adverse effect on historic properties.

(11) Radio frequency emissions and noninterference. The applicant shall comply with all applicable Federal Communication Commission standards.

The applicant has indicated that they will meet all regulations established by the Federal Communications Commission.

(12) Public safety communication system. The location of the proposed antenna, if located on publicly owned property, shall not be needed for use by the public safety communication system, or if needed, it shall be determined by the director of the property services division of the finance department that co-location of the proposed antenna with a public safety antenna is agreeable.

Not applicable.

RECOMMENDATIONS

The Department of Community Planning and Economic Development recommends that the City Planning Commission adopt staff findings for the application(s) by Kristian Olson for the properties located at 1201 West Broadway:

A. Conditional Use Permit for a telecommunications tower.

Recommended motion: Approve the application for a telecommunication tower, subject to the following conditions:

1. The conditional use permit shall be recorded with Hennepin County as required by Minn. Stat. 462.3595, subd. 4 before building permits may be issued or before the use or activity requiring a

Page 9: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Department of Community Planning and Economic Development PLAN5232

9

conditional use permit may commence. Unless extended by the zoning administrator, the conditional use permit shall expire if it is not recorded within two years of approval.

2. The applicant shall submit a letter from a licensed engineer stating that the tower has the structural integrity to withstand typical wind loads and inclement weather.

3. The applicant shall provide landscaping and screening to the base of the tower and mechanical equipment as required by sections 535.70 and 535.540(3) of the zoning code.

4. The chain-link fence used to screen the base of the telecommunications tower and mechanical equipment shall be vinyl-coated and shall not include barbed wire.

5. The applicant shall plant three (3) deciduous, canopy trees on the site along Fremont Avenue N. The canopy trees shall be capable of growing to at least fifty (50) feet in height. The trees shall be at least 3” caliper size at the time of installation. The tree species, installation and maintenance shall comply with sections 530.200 and 530.210 of the zoning code. CPED staff shall review the proposed canopy trees prior to issuing building permits.

6. The proposed telecommunications tower shall be constructed of, or treated with, a corrosive resistant material and be painted light blue to blend in with the sky. All proposed antennas, supporting equipment and structural equipment upon which they are mounted shall be painted to match the tower.

7. No portion of the mounting pipes shall extend above or below the antenna. Empty mounting pipes shall not be permitted. No antennas shall protrude above the tower.

8. The visibility of cables and wires will be reduced whenever possible. Exposed cables will be painted to match the tower. Free-floating wires will only be permitted when no other concealment option is available.

ATTACHMENTS

1. Zoning map 2. Oblique aerial photo 3. Written description and findings submitted by applicant 4. Site plan 5. Landscape plan 6. Tower details 7. Survey 8. Photos and renderings

Page 10: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

1250

1801

1000

1225

1800

1500

904

2105

1814

1831

1524

1200

1830

2100

1120

1401

1617

1834

2015

1501

1514

1704

1127

2011

1310

10251301

1303

1300

1628

1511

1312

1522

2129

1400

1506

1823

2017

1624

17121716

1709

1724

1713

1728

171717231731

1404

2117

1515

1630

11142101

2126

21092115

2110211221182120

2111

211921212125

20192025

20102014

1810

1519

1805

1029

1314

1115 1111 1625

1727

2131

1012

161416181622

16131619

1615

16231616

170017061710

17011707

1722

171117151719

1409

1837

2020

1827

1835

1826

18111815

2135

1534

2018

1101

1311

11131119

1822

1839

1315

2108

211621222124

14031405

1410

1414

1806

1415

1836

1100

1725

1627

1529

9271013

1523

1621

21272123

1817

1015

1525

1307

1418

1631

2013

1832

1818

1004

1825

2106

1816

1108

1521

1417

1819

1807

2137

1730

17181714

1517

18241820

1513

2114

1726

1124

1213

21302134

1829

1803

2026

1527

2107

1117

1215

14071411

140814061412

1413

1530

1538

1313

1542

1001

1317

1422

1319

1546

1512

1007

1838

1533

1105

10191017

1318

10101008

1021

1502

1531

1005

1112

1110

1109

1550

16261620

1516

1402

2128

1509

1828

1106

1537

1316 16101611 1608 1609

1541

R2B

OR2 R2B

C1

C2R5

R3

R1A

R4R1A

R4

OR2

I1

17TH AVE N

IRVIN

G AVE

N

GIRA

RD AV

E N

EMER

SON

AVE N

FREM

ONT A

VE N

WEST BROADWAY

DUPO

NT AV

E N

18TH AVE N

DUPO

NT AV

E N

R5

R2BR4

R4

R4

R3

R4OR1

OR1

200 0 200 400 600100 Feet¹FILE NUMBER

NAME OF APPLICANT WARD

PROPERTY ADDRESS

Kristian Olson

1201 West Broadway PLAN5232

5th

Page 11: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,
Page 12: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Kristian Olson Buell Consulting Inc, on behalf of Eco-Site Re: CUP Application at 1201/1225 West Broadway Ave W 10/6/2017

Statement of Proposed Use and Description of the Eco-Site Tower Project at 1201/1225 West Broadway Ave North, Minneapolis, MN

On behalf of Eco-Site, LLC, we are requesting a Conditional Use Permit for the installation of a 105’ tall (with 4’ lightning rod, 109’ overall) monopole telecommunications tower on property located at 1201/1225 West Broadway Avenue North in Minneapolis. The tower is being built for the purpose of installing a new T-Mobile telecommunications facility (installation of T-Mobile’s antennas on the tower and base station equipment near the tower base), but will be available for colocation by other wireless communications providers as well.

The tower will be located directly behind an existing church building on the property and enclosed within a 58’ x 34’ fenced compound. The tower is designed to accommodate at least three total carriers and the 8’ tall chain-link security fence at the base of the tower covers a large enough area to accommodate the future base station equipment of any future co-locators. The fence will also be gated and locked at all times.

The tower compound is located behind the existing main building owned by Shiloh Temple International Ministries, in between the building and the existing parking lot. The proposed tower compound is bordered by the main building to the north, an outdoor play area to the east, the existing parking lot to the south, and an access drive and utilities to the west. The tower will be of a monopole design, as required by the zoning ordinance.

New landscaping is also planned to the east and west of the compound to provide additional screening for the property owner and other nearby properties. This involves small evergreen ferns to the west and one to three trees to the east. The trees to the east are to provide additional screening and also replace the existing tree that will be removed at the tower site.

The proposed tower has been designed to meet all required setbacks, to discourage any unauthorized climbing, and it shall not contain any advertising or signage outside of applicable warning or cautionary signage required by regulation.

Page 13: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

Kristian Olson Buell Consulting Inc, on behalf of Eco-Site Re: CUP Application at 1201/1225 West Broadway Ave W 10/6/2017

Statement on Required Findings for a Conditional Use Permit for Eco-Site Tower Project at 1201/1225 West Broadway Ave North, Minneapolis, MN

1. The establishment, maintenance or operation of the conditional use will not be detrimental to or endanger the public health, safety, comfort or general welfare.

The installation, maintenance and operation of the proposed tower and conditional use will be in full compliance with local, state and federal laws, including but not limited to the ordinance of the city of Minneapolis as well as standard regulations as set forth by the FCC and OSHA. The site will also be secured with a locked and gated security fence. As a result, the site will not be detrimental to or endanger the public health, safety, comfort or general welfare. It has been designed in accordance with the performance standards of the Minneapolis ordinance and it meets all setbacks and requirements.

2. The conditional use will not be injurious to the use and enjoyment of other property in the vicinity and will not impede the normal and orderly development and improvement of surrounding property for uses permitted in the district.

The conditional use of the telecommunications facility will not be injurious to any existing or proposed uses or enjoyment in the vicinity, nor will it impede the development and/or improvement of surrounding properties. The entire facility is confined to the fenced area behind the church building and much of the lower part of the tower and compound is screened by surrounding buildings and existing vegetation. The tower will not be lighted at night, nor will it create any disturbances of any kind to others in the vicinity.

3. Adequate utilities, access roads, drainage, necessary facilities or other measures, have been or will be provided.

The proposed telecommunications facility has fully adequate utilities adjacent to or already existing on the subject parcel. There is already adequate drainage and access roads as well.

4. Adequate measures have been or will be taken to minimize traffic congestion in the public streets.

Page 14: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

The proposed telecommunications facility should have no impact on traffic congestion. The facility is un-manned and outside of initial installation, T-Mobile’s technicians will visit the site on an average of once every 1-3 months.

5. The conditional use is consistent with the applicable policies of the comprehensive plan.

The conditional use of this telecommunications facility is consistent with the policies of the comprehensive plan and follows the Minneapolis Zoning Ordinance completely for how and where telecommunications towers are to be located, designed, and built.

6. The conditional use shall, in all other respects, conform to the applicable regulations of the district in which it is located.

The conditional use of this telecommunications facility will in all other respects, conform to the applicable regulations of the OR2, High Density Office Residence District.

Page 15: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,
Page 16: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,
Page 17: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,
Page 18: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,
Page 19: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,
Page 20: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

GA

S

GAS

GAS

GAS

GAS

GASGAS

UG

E

UGE

UGF UGF UGF UGF UGF UGF UGF

144.47'

DISTANCE FROM PROPERTY LINE TO PROPOSED TOWER

240 LEIGH FARM ROAD

SUITE 415

DURHAM, NC 27707

ECO-SITE.COM

D

COUNTY

ECO-SITE: BROADWAY AVE/MN-0031

T-MOBILE: SHILOH TEMPLE/A1O0769B

ZONING

NOT FOR

CONSTRUCTION

1201 W. BROADWAY AVE N

MINNEAPOLIS, MN 55411

09/19/17

ZONING

110-056

BUELL CONSULTING INC.

1360 ENERGY PARK DRIVE, SUITE 210

ST. PAUL, MN 55108

(651) 361-8110

www.buellconsulting.com

DM DMML

1

SCALE: 1" = 20'-0"

LOCATION PLAN

0

SC

ALE

1" =

22" x 34" PRINT IS THE FULL SCALE

FORMAT. ANY SIZE OTHER THAN

THAT IS AT REDUCED SCALE.

10' 20' 40'

20

'

LOCATION PLAN

LP

EXISTING

SCHOOL

BUILDING

EXISTING

ASPHALT

PARKING LOT

PROPOSED 105' HIGH GALVANIZED

STEEL MONOPOLE TOWER (NEUTRAL

LIGHT GRAY UNPAINTED GALVANIZED)

PROPOSED (58'x34') ECO-SITE

TOWER COMPOUND LEASE AREA

EXISTING

GRASS

AREA

BROADWAY AVE

FR

EM

ON

T A

VE

GIR

AR

D A

VE

EXISTING

SANDY

AREA

EXISTING

ASPHALT

PARKING LOT

EXISTING

ASPHALT

PARKING LOT

PR

OP

ER

TY

/R

.O

.W

. L

IN

E

EXISTING TELCO/FIBER

COMMUNICATIONS BOX

PROPOSED 15' WIDE

ACCESS EASEMENT

PROPOSED 20' WIDE

UTILITY EASEMENT

PROPOSED 20' WIDE

UTILITY EASEMENT

EXISTING

RESIDENTIAL

BUILDING

GOLDEN VALLEY RD.

230'

APPROXIMATE DISTANCE FROM TOWER TO NEAREST RESIDENCE BUILDING

AP

PR

OX

IM

AT

E R

.O

.W

. L

IN

E

APPROXIMATE R.O.W. LINE

AP

PR

OX

IM

AT

E R

.O

.W

. LIN

E

21

9.7

'

DIS

TA

NC

E F

RO

M P

RO

PE

RT

Y L

IN

E T

O P

RO

PO

SE

D T

OW

ER

192.67'

DISTANCE FROM PROPERTY LINE TO PROPOSED TOWER

97

.5

8'

DIS

T. F

RO

M P

RO

PE

RT

Y L

IN

E T

O P

RO

PO

SE

D T

OW

ER

APPROXIMATE PROPERTY LINE

EXISTING PLAYGROUND EQUIPMENT

WITH SLIDES TO BE RELOCATED 6'

MIN. AWAY FROM PROPOSED FENCE

(2) PROPOSED

DECIDUOUS TREES

R

2

1

8

'

T

O

W

E

R

S

E

T

-

B

A

C

K

R

A

D

I

U

S

EXISTING

RESIDENTIAL

BUILDING

EXISTING

RESIDENTIAL

BUILDING

EXISTING TREE

(TYP.)

EXISTING UTILITY

TRANSFORMER

PROPOSED (25) EVERGREEN

SHRUBS. SEE SHEET L-1

AutoCAD SHX Text
AC
AutoCAD SHX Text
CURRENT ISSUE DATE:
AutoCAD SHX Text
BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
REV.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
LICENSER:
AutoCAD SHX Text
APV.:
AutoCAD SHX Text
CHK.:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
PROJECT INFORMATION:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
A
AutoCAD SHX Text
ML
AutoCAD SHX Text
07/14/17
AutoCAD SHX Text
REVIEW
AutoCAD SHX Text
B
AutoCAD SHX Text
ML
AutoCAD SHX Text
09/29/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
C
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/06/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
D
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/30/17
AutoCAD SHX Text
ZONING
Page 21: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

GA

S

GA

S

GAS

GAS

GAS

240 LEIGH FARM ROAD

SUITE 415

DURHAM, NC 27707

ECO-SITE.COM

D

COUNTY

ECO-SITE: BROADWAY AVE/MN-0031

T-MOBILE: SHILOH TEMPLE/A1O0769B

ZONING

NOT FOR

CONSTRUCTION

1201 W. BROADWAY AVE N

MINNEAPOLIS, MN 55411

09/19/17

ZONING

110-056

BUELL CONSULTING INC.

1360 ENERGY PARK DRIVE, SUITE 210

ST. PAUL, MN 55108

(651) 361-8110

www.buellconsulting.com

DM DMML

SITE DIMENSION PLAN

1

SCALE: 1" = 10'-0"

EQUIPMENT ENLARGED PLAN

0

SC

AL

E 1

" =

22" x 34" PRINT IS THE FULL SCALE

FORMAT. ANY SIZE OTHER THAN

THAT IS AT REDUCED SCALE.

5' 10'20'

10'

PROPOSED MULTI-GANG

METER & FIBER H-FRAME,

MIN. 4'-6" CLEAR TO FENCE

ENLARGED SITE PLAN

C-1

PROPOSED (10'x8') T-MOBILE EQUIPMENT

GALV. STEEL PLATFORM (COLOR = GRAY)

PROPOSED (10'x15') T-MOBILE

EQUIPMENT LEASE AREA

EXISTING CHAIN

LINK FENCE

PROPOSED (53.8'x26') CHAIN

LINK FENCED COMPOUND

WITHOUT BARBED WIRE

EXISTING

GRASS

AREA

PROPOSED 15' WIDE

ACCESS EASEMENT

EXISTING CHAIN LINK FENCE

TO BE REMOVED

PROPOSED CONCRETE FILLED

PROTECTION BALLARD (TYP. 2)

PROPOSED (58'x34') ECO-SITE

TOWER COMPOUND LEASE AREA

EXISTING

SAND AREA

8'

4'

EXISTING DUMPSTER

EXISTING UTILITY

TRANSFORMER

EXISTING

ASPHALT

PARKING LOT

EXISTING

SCHOOL

BUILDING

PROPOSED 12' WIDE SLIDING GATE

EXISTING PARKING SPOTS

TO BE REMOVED

PROPOSED PARKING SPOTS

TO BE RELOCATED 2 FEET

EXISTING TREE TO BE REMOVED

26'

33'

57

.8

'

53

.8

'

12'

ACCESS GATE

±14'

13.8'

23

.4

2'

10'

15

'

10

'

20

'

EXISTING CONCRETE CURB

& ASPHALT PAVEMENT AREA

TO BE REMOVED

PROPOSED 20' WIDE

UTILITY EASEMENT

9'

MIN.

EXISTING PLAYGROUND

EQUIPMENT WITH SLIDES TO

BE RELOCATED 6' MIN. AWAY

FROM PROPOSED FENCE

PROPOSED 105' HIGH GALVANIZED

STEEL MONOPOLE TOWER (NEUTRAL

LIGHT GRAY UNPAINTED GALVANIZED)

PROPOSED (25) EVERGREEN

SHRUBS. SEE SHEET L-1

5'

TY

P.

12

.7

9'

3'

AutoCAD SHX Text
AC
AutoCAD SHX Text
CURRENT ISSUE DATE:
AutoCAD SHX Text
BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
REV.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
LICENSER:
AutoCAD SHX Text
APV.:
AutoCAD SHX Text
CHK.:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
PROJECT INFORMATION:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
A
AutoCAD SHX Text
ML
AutoCAD SHX Text
07/14/17
AutoCAD SHX Text
REVIEW
AutoCAD SHX Text
B
AutoCAD SHX Text
ML
AutoCAD SHX Text
09/29/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
C
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/06/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
D
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/30/17
AutoCAD SHX Text
ZONING
Page 22: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

240 LEIGH FARM ROAD

SUITE 415

DURHAM, NC 27707

ECO-SITE.COM

D

COUNTY

ECO-SITE: BROADWAY AVE/MN-0031

T-MOBILE: SHILOH TEMPLE/A1O0769B

ZONING

NOT FOR

CONSTRUCTION

1201 W. BROADWAY AVE N

MINNEAPOLIS, MN 55411

09/19/17

ZONING

110-056

BUELL CONSULTING INC.

1360 ENERGY PARK DRIVE, SUITE 210

ST. PAUL, MN 55108

(651) 361-8110

www.buellconsulting.com

DM DMML

(OPERATIONS PROVIDED) 4 NO-TRESSPASSING SIGN

5 ECO-SITE ID SIGN18" HIGH X 24" WIDE

SIGNAGE NOTES:

1. SIGNS SHALL BE FABRICATED FROM CORROSION RESISTANT

PRESSED METAL, AND PAINTED WITH LONG LASTING UV

RESISTANT COATINGS.

2. SIGNS (EXCEPT WHERE NOTED OTHERWISE) SHALL BE

MOUNTED TO THE TOWER, GATE, AND FENCE USING A

MINIMUM OF 9 GAUGE ALUMINUM WIRE, HOG RINGS (AS

UTILIZED IN FENCE INSTALLATIONS) OR BRACKETS WHERE

NECESSARY. BRACKETS SHALL BE OF SIMILAR METAL AS THE

STRUCTURE TO AVOID GALVANIC CORROSION.

HERE AND ON ANY

GATED ACCESS ENTRTY

SEE DETAIL ABOVE

FRONT GATE

4

5

1

2

3

12" x 18" DIGITAL PRINT MOUNTED TO 0.40THICK ALUMINUM

(OPERATIONS PROVIDED)

1 NOTICE - RF SIGN (BLUE)12" x 18" DIGITAL PRINT MOUNTED TO 0.40

THICK ALUMINUM(OPERATIONS PROVIDED)

2 CAUTION - RF SIGN (YELLOW)12" x 18" DIGITAL PRINT MOUNTED TO 0.40

THICK ALUMINUM(OPERATIONS PROVIDED)

3 WARNING - RF SIGN (RED)12" x 18" DIGITAL PRINT MOUNTED TO 0.40

THICK ALUMINUM(OPERATIONS PROVIDED)

TYPICAL SIGNS AND SPECIFICATIONS

2

N.T.S.

12"x18" .040

ALUMINUM

NO TRESPASSING

AUTHORIZED

PERSONNEL

ONLY

SITE I.D.#:

SITE NAME:

E911 ADDRESS:

FCC#:

EMERGENCY CONTACT

(866) 899-6191

FOR TOWER LEASING INFORMATION &

SITE SIGNAGE FRONT GATE VIEW

3

N.T.S.

SITE

SIGNAGE

DETAILS

C-2

1

N.T.S.

OVERALL SIGN PLACEMENT PLAN VIEW

TOP

BTM

BTM

3

2

TOP

5

1

GATE

COMPOUND

FENCE

4

4

4

BUILDING

AutoCAD SHX Text
CURRENT ISSUE DATE:
AutoCAD SHX Text
BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
REV.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
LICENSER:
AutoCAD SHX Text
APV.:
AutoCAD SHX Text
CHK.:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
PROJECT INFORMATION:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
A
AutoCAD SHX Text
ML
AutoCAD SHX Text
07/14/17
AutoCAD SHX Text
REVIEW
AutoCAD SHX Text
B
AutoCAD SHX Text
ML
AutoCAD SHX Text
09/29/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
C
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/06/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
D
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/30/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
WARNING
AutoCAD SHX Text
ABOVE THIS POINT:
AutoCAD SHX Text
Radio frequency emissions may exceed controlled exposure limits.
AutoCAD SHX Text
For your safety, obey all posted signs and site guidelines for working in radio frequency enviroments
AutoCAD SHX Text
In accordance with Federal Communications Commission rules on radio frequency emissions 47 CFR 1.1307(b)
AutoCAD SHX Text
YELLOW BACKGROUND w/BLACK LETTERING
AutoCAD SHX Text
WHITE BACKGROUND w/BLACK LETTERING AND YELLOW SYMBOL
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text
Radio frequency environment area. Authorized personnel only beyond this point.
AutoCAD SHX Text
Personnel proceeding beyond this point must obey all posted signs, site guidelines and Federal Regulations for working in radio frequency environments.
AutoCAD SHX Text
In accordance with Federal Regulations on radio frequency emissions.
AutoCAD SHX Text
BLUE BACKGROUND w/WHITE LETTERING
AutoCAD SHX Text
WHITE BACKGROUND w/BLACK LETTERING AND BLACK SYMBOL
AutoCAD SHX Text
CAUTION
AutoCAD SHX Text
BEYOND THIS POINT:
AutoCAD SHX Text
Radio frequency fields at this site may exceed FCC rules for human exposure.
AutoCAD SHX Text
For your safety, obey all posted signs, site guidelines and federal regulations for working in radio frequency environments.
AutoCAD SHX Text
In accordance with Federal Communications Commission rules on radio frequency emissions 47 CFR 1.1507(b)
AutoCAD SHX Text
RED BACKGROUND w/BLACK LETTERING
AutoCAD SHX Text
WHITE BACKGROUND w/BLACK LETTERING AND RED SYMBOL
AutoCAD SHX Text
BEYOND THIS POINT:
Page 23: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

240 LEIGH FARM ROAD

SUITE 415

DURHAM, NC 27707

ECO-SITE.COM

D

COUNTY

ECO-SITE: BROADWAY AVE/MN-0031

T-MOBILE: SHILOH TEMPLE/A1O0769B

ZONING

NOT FOR

CONSTRUCTION

1201 W. BROADWAY AVE N

MINNEAPOLIS, MN 55411

09/19/17

ZONING

110-056

BUELL CONSULTING INC.

1360 ENERGY PARK DRIVE, SUITE 210

ST. PAUL, MN 55108

(651) 361-8110

www.buellconsulting.com

DM DMML

AT TOWER

FINISH GRADE

1

SCALE: 1/8" = 1'-0"

SOUTH ELEVATION

PROPOSED LIGHTNING ROD

PROPOSED T-MOBILE ANTENNAS &

MOUNTING PLATFORM @ 100' A.G.L.

(ANTENNA PAINTED TO MATCH TOWER)

PROPOSED T-MOBILE EQUIPMENT CABINETS

ON GALVANIZED STEEL PLATFORM

PROPOSED 8' HIGH CHAIN-LINK

FENCE WITHOUT BARBED WIRE

(PARTIALLY SHOWN FOR CLARITY)

PROPOSED ANTENNA LAYOUT

2

N.T.S.

(6) PROPOSED PANEL ANTENNAS

(TYP. OF 2 PER SECTOR)

PROPOSED COVP DEVICE PIPE

MOUNTED TO PLATFORM

(9) RRU DEVICES PIPE MOUNTED

(TYP. OF 3 PER SECTOR)

SITE ELEVATION

ANTENNA

INFORMATION

ANT-10

SCALE:

22" x 34" PRINT IS THE FULL SCALE

FORMAT. ANY SIZE OTHER THAN

THAT IS AT REDUCED SCALE.

1/2" 1" 2"

1/8" = 1'-0"

10

0'

DIS

TA

NC

E T

O C

EN

TE

R O

F P

RO

PO

SE

D L

ES

SE

E A

NT

EN

NA

S

10

5'

HE

IG

HT

O

F P

RO

PO

SE

D M

ON

OP

OL

E T

OW

ER

10

9'

OV

ER

AL

L H

EIG

HT

O

F P

RO

PO

SE

D M

ON

OP

OL

E T

OW

ER

&

L

IG

HT

NIN

G R

OD

PROPOSED 8' HIGH GALVANIZED STEEL

CABLE ICE-BRIDGE (COLOR = GREY)

ANTENNA SCHEDULE

SECTOR

TECHNOLOGY

AZIMUTH

RAD CENTER

ANTENNA MFR.

MODEL #

MECH. DOWNTILT

PORT

ALPHA

A-1

U1900/L1900/L700

20°

100'

COMMSCOPE

FHH-65C-R3 (HEX)

P1

A-2

L2100/L600

20°

COMMSCOPE

FHH-65C-R3 (HEX)

BETA

B-1

120°

B-2

120°

GAMMA

G-1

240°

G-2

240°

100'

0° 0°

100'

COMMSCOPE

FHH-65C-R3 (HEX)

100' 100'

COMMSCOPE

FHH-65C-R3 (HEX)

100'

U1900/L1900/L700 L2100/L600

U1900/L1900/L700

L2100/L600

COMMSCOPE

FHH-65C-R3 (HEX)

COMMSCOPE

FHH-65C-R3 (HEX)

ELEC. DOWNTILT

P3 P5

4 4

LOCATION

4

P2

4

P4

4

P6

4

P1 P3 P5

4 4 4

P2

4

P4

4

P6

4

P1 P3 P5

4 4 4

P2

4

P4

4

P6

4

SECTOR - X

AZ = 20°

SECTOR - Y

AZ = 120°

SECTOR - Z

AZ = 240°

A

-

1

U

1

9

0

0

/

1

9

0

0

/

L

7

0

0

A

-

2

L

2

1

0

0

/

L

6

0

0

B

-

1

U

1

9

0

0

/

1

9

0

0

/

L

7

0

0

B

-

2

L

2

1

0

0

/

L

6

0

0

C

-

1

U

1

9

0

0

/

1

9

0

0

/

L

7

0

0

C

-

2

L

2

1

0

0

/

L

6

0

0

FUTURE CARRIER ANTENNAS

& PLATFORM

8'

BR

ID

GE

8'

FE

NC

E

PROPOSED 105' HIGH GALVANIZED

STEEL MONOPOLE TOWER (NEUTRAL

LIGHT GRAY UNPAINTED GALVANIZED)

PROPOSED LANDSCAPE SHRUB

AutoCAD SHX Text
CURRENT ISSUE DATE:
AutoCAD SHX Text
BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
REV.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
LICENSER:
AutoCAD SHX Text
APV.:
AutoCAD SHX Text
CHK.:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
PROJECT INFORMATION:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
A
AutoCAD SHX Text
ML
AutoCAD SHX Text
07/14/17
AutoCAD SHX Text
REVIEW
AutoCAD SHX Text
B
AutoCAD SHX Text
ML
AutoCAD SHX Text
09/29/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
C
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/06/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
D
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/30/17
AutoCAD SHX Text
ZONING
Page 24: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

OH

EO

HE

OH

EO

HE

OH

EO

HE

OH

EO

HE

OH

E

OH

E

240 LEIGH FARM ROAD

SUITE 415

DURHAM, NC 27707

ECO-SITE.COM

D

COUNTY

ECO-SITE: BROADWAY AVE/MN-0031

T-MOBILE: SHILOH TEMPLE/A1O0769B

ZONING

NOT FOR

CONSTRUCTION

1201 W. BROADWAY AVE N

MINNEAPOLIS, MN 55411

09/19/17

ZONING

110-056

BUELL CONSULTING INC.

1360 ENERGY PARK DRIVE, SUITE 210

ST. PAUL, MN 55108

(651) 361-8110

www.buellconsulting.com

DM DMML

1

SCALE: 1" = 10'-0"

LANDSCAPE PLAN

0

SC

ALE

1

" =

22" x 34" PRINT IS THE FULL SCALE

FORMAT. ANY SIZE OTHER THAN

THAT IS AT REDUCED SCALE.

5' 10' 20'

10

'

LANDSCAPE PLAN

L-1

PROPOSED (10'x8') T-MOBILE EQUIPMENT

GALV. STEEL PLATFORM (COLOR = GREY)

PROPOSED (10'x15') T-MOBILE

EQUIPMENT LEASE AREA

EXISTING CHAIN

LINK FENCE

PROPOSED (53.8'x26') CHAIN

LINK FENCED COMPOUND

WITHOUT BARBED WIRE

EXISTING

GRASS

AREA

PROPOSED CONCRETE FILLED

PROTECTION BALLARD (TYP. 2)

EXISTING

SAND AREA

EXISTING DUMPSTER

EXISTING UTILITY

TRANSFORMER

EXISTING

ASPHALT

PARKING LOT

EXISTING

SCHOOL

BUILDING

EXISTING

PLAY

GROUND

PROPOSED 12' WIDE

SLIDING GATE

6.

4.

5.

3.

1.

2.

APPROVAL. IT SHALL BE FREE OF ADMIXTURES OF SUBSOIL AND FREE OF CRAB

SEEDING WORK SHALL BE DONE PAST SEPTEMBER 15, UNLESS APPROVED BY THE

SEED: SEED MIX SHALL MATCH EXISTING TURF, OR BE A 50/50 MIX OF CERTIFIED

IMPROVED BLEND OF BLUEGRASS AND CERTIFIED IMPROVED PERENNIAL RYE. MIX

SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO PLANTING.

FUTERRA BLANKET, OR EQUAL, SHALL BE USED FOR EROSION CONTROL MULCH

GRASS, ROOTS, STICKS AND OTHER EXTRANEOUS MATTER, AND SHALL NOT

BE USED FOR PLANTING OPERATIONS WHILE IN A FROZEN OR MUDDY

REPAIR ALL TURF AREAS BY SEEDING. SEEDING INSTALLATION SHALL BE

EXECUTED ONLY AFTER ALL FINISH GRADING HAS BEEN COMPLETED. NO

SEEDING SHALL BE APPLIED AT A MINIMUM RATE OF 120 POUNDS PER ACRE.

WHERE NECESSARY IN LIEU OF HYDRO MULCH.

OWNER'S REPRESENTATIVE.

CONDITIONS.

ADDITIONAL COST TO THE OWNER, PLANT MATERIALS THAT ARE DEAD, OR IN THE

CONTRACTORS CONTROL WHICH RESULT FROM NATURAL CAUSES SUCH AS FLOODS

ABUSE, DAMAGE BY OTHERS, OR UNUSUAL PHENOMENA OR INCIDENTS BEYOND THE

CONTRACTOR WILL NOT BE RESPONSIBLE FOR DEFECTS RESULTING FROM NEGLECT

ALL PLANTING STOCK SHALL BE NURSERY-GROWN IN ACCORDANCE WITH GOOD

COMPOSTED PINE BARK MULCH FREE OF FOREIGN MATERIAL AND LARGE PIECES

CONDITION. REJECTED PLANT MATERIALS SHALL BE REMOVED FROM THE SITE

OPINION OF THE LANDSCAPE ARCHITECT, IN AN UNHEALTHY OR UNSIGHTLY

REPLACEMENTS: DURING THE WARANTY PERIOD, REPLACE ONE TIME, AT NO

AT CONTRACTOR'S EXPENSE. REPLACEMENTS ARE TO BE MADE NO LATER

THAN THE SUBSEQUENT PLANTING SEASON. RESTORE AREAS DISTURBED BY

MULCHING SHALL BE DONE WITHIN 48 HOURS AFTER PLANTING. MULCH SHRUB

BEDS TO A UNIFORM DEPTH OF THREE INCHES. MULCH SHALL BE CLEAN

OVER THREE INCHES LONG. DO NOT MULCH TREE AND SHRUB PLANTING PITS.

TOPSOIL SHALL CONSIST OF FERTILE FRIABLE NATURAL LOAM, CONTAINING A

LIBERAL AMOUNT OF HUMUS AND SHALL BE SUBJECT TO INSPECTION AND

REPLACEMENT OPERATIONS.

STORMS, FIRES OR VANDALISM.

UNSATISFACTORY GROWTH FOR A WARRANTY PERIOD OF ONE YEAR. THE

MATERIALS SHALL BE WARRANTED AGAINST DEFECTS, INCLUDING DEATH AND

NAME AND SPECIFIED SIZE. AFTER COMPLETION OF PLANTING, ALL PLANT

GUARENTEE: WARRANT ALL PLANT MATERIAL TO BE TRUE TO BOTANICAL

MINIMUM QUALITY AND SIZE CONFORMING TO AMERICAN STANDARD FOR

VARIETY, WELL-FORMED, FREE FROM IRREGULARITIES, WITH THE

VIGOROUS AND UNIFORM GROWTH TYPICAL OF THE SPECIES AND

ABRASIONS OR DISFIGUREMENT. THEY SHALL HAVE SOUND, HEALTHY

EGGS, LARVAE AND DEFECTS SUCH AS KNOTS, SUN-SCALD, INJURIES,

HORTICULTURAL PRACTICE. PLANTS SHALL BE FREE OF DISEASE, INSECTS

TO THE GENERAL SHAPE OF THE SHRUB TYPE. DO NOT USE HEDGE SHEARS.

STANDARDS. PRUNING SHALL RESULT IN A LOOSE OUTLINE CONFORMING

PERSONNEL TO THE ACCEPTED HORTICULTURAL AND ARBORICULTURAL

PRUNE NEWLY INSTALLED SHRUBS. WORK SHALL BE DONE BY EXPERIENCED

NURSERY STOCK.

GENERAL LANDSCAPE NOTES

COMMON NAMEBOTANICAL NAME

PLANT LIST

SYMBOL

TREES

PG

3

SIZE

PLANT SYMBOL

PLANT QUANTITY

QUANTITY COMMENTS

EVERGREEN TREE PLANTING

1/2X

3X

X

N.T.S.

1/2X

PLANTING BACKFILL

3" SHREDDED

BARK MULCH

5" MULCH SAUCER

TO HOLD WATER

FINISH GRADE

PLANTING BACKFILL

TREE ROOT BALL

-SET ORIGINAL GROUND

LINE OF ROOTBALL AT

FINISH GRADE

-REMOVE TOP 1/3 OF

BURLAP AND NYLON ROPE

UNDISTURBED

SUBGRADE

-

XX

2

PROPOSED 105' MONOPOLE TOWER

PROPOSED (58'x34') ECO-SITE

TOWER COMPOUND LEASE AREA

EXISTING

ASPHALT

PARKING LOT

--XX B & B (BALLED & BURLAPPED)10 FT. HT. MIN.2

HOLMSTRUP EASTERN ARBORVITAE'HOLMSTRUP' B & B (BALLED & BURLAPPED)6 FT. HT. MIN.25

PROPOSED DECIDUOUS TREE

TX

16

THUJA OCCIDENTALISTX

5'2'

5'

TY

P.

2'

2'

2'

AutoCAD SHX Text
AC
AutoCAD SHX Text
CURRENT ISSUE DATE:
AutoCAD SHX Text
BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
REV.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
CONSULTANT:
AutoCAD SHX Text
LICENSER:
AutoCAD SHX Text
APV.:
AutoCAD SHX Text
CHK.:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ISSUED FOR:
AutoCAD SHX Text
PROJECT INFORMATION:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
SHEET NUMBER:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
A
AutoCAD SHX Text
ML
AutoCAD SHX Text
07/14/17
AutoCAD SHX Text
REVIEW
AutoCAD SHX Text
B
AutoCAD SHX Text
ML
AutoCAD SHX Text
09/29/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
C
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/06/17
AutoCAD SHX Text
ZONING
AutoCAD SHX Text
D
AutoCAD SHX Text
ML
AutoCAD SHX Text
10/30/17
AutoCAD SHX Text
ZONING
Page 25: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,
Page 26: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,
Page 27: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

600 Busse Highway, Park Ridge, IL 60068Phone: 847.698.6400 Fax: 847.698.6401

AFTER

BEFORE

MN-0031

SHILOH TEMPLE

A1O0769B

View from Northwest

PROPOSED

ANTENNA TOWER

Page 28: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

600 Busse Highway, Park Ridge, IL 60068Phone: 847.698.6400 Fax: 847.698.6401

MN-0031

SHILOH TEMPLE

A1O0769B

View from East

AFTER

BEFORE

PROPOSED

ANTENNA TOWER

PROPOSED T-MOBILE

EQUIPMENT PLATFORM

Page 29: CPED STAFF REPORT LAND USE APPLICATION SUMMARYcped/...may consider the substitution of alternative tower types in cases where structural, radio frequency, and design considerations,

600 Busse Highway, Park Ridge, IL 60068Phone: 847.698.6400 Fax: 847.698.6401

MN-0031

SHILOH TEMPLE

A1O0769B

View from Southeast

AFTERBEFORE

PROPOSED

ANTENNA TOWER

PROPOSED T-MOBILE

EQUIPMENT PLATFORM