— APPLICATION NOTE
CP600 CONVERTING A CP600
PROJECT TO A CP600 2ND
GENERATION PROJECT HINTS AND TIPS
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 2
Contents
1 Introduction ................................................................................................................................ 3 1.1 Scope of the document .............................................................................................................. 3 1.2 Compatibility ................................................................................................................................ 3 1.3 Overview ........................................................................................................................................ 3
2 General Differences ................................................................................................................... 4 2.1 Hardware, OS ............................................................................................................................... 4 2.2 Interfaces and Slots ................................................................................................................... 4 2.3 SD Card.......................................................................................................................................... 4 2.4 Licenses ........................................................................................................................................ 4 2.5 Replacement Options .................................................................................................................5
3 Convert Application ................................................................................................................... 6 3.1 Update Project or new Project ................................................................................................. 6 3.2 Convert Project with Panel Builder with same screen size ................................................ 6 3.3 Convert Project with Panel Builder with different screen size ......................................... 9
CP600 CONVERTING A CP600 PROJECT TO A CP60 0 2ND GENERATION PROJECT
3ADR010541, 2, en_US 3
1 Introduction
1.1 Scope of the document
Support Users to convert a project made for CP600 to project for CP600 2nd.
The document describes the general differences between the CP600 and CP600 2nd genera-
tion and gives some hints to execute all necessary steps for conversion.
1.2 Compatibility
The application example explained in this document have been used with the below engineer-
ing system versions. They should also work with other versions, nevertheless some small ad-
aptations may be necessary, for future versions.
• CP600 / CP600 2nd generation
• Panel Builder V2.8.1.477 or newer
1.3 Overview
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 4
2 General Differences
2.1 Hardware, OS
CP6xx CP64xx
Processor Speed ARM Cortex A8 600MHz ARM Cortex A8 1 GHz
Memory • Flash Disk 128Mbyte
• 256MB DDR
• Flash Disk 4 GB
• 512 MB DDR
Operating System Microsoft Windows CE 6.0 Linux
Application Memory 30…60MB 150 MB
2.2 Interfaces and Slots
CP6xx CP64xx
Ethernet 2x ETH 10/100 Mbit 2x ETH 10/100 Mbit
Serial ports 1x SER RS-232/-485/-422 1x SER RS-232/-485/-422
Card Slot 1x SD-card Slot 1x SD-card Slot
USB 2x USB Host 2x USB Host
2.3 SD Card
CP6xx CP64xx
Size Max. 2 GB (ABB tested Cards) Max. 2 GB (ABB tested Cards)
Format Standard SDHC supported (Delivery from
ABB in preparation)
Card Function • Update Project
• Update Runtime
• Update Project
• Update Runtime
2.4 Licenses
Same as before. There are no changes in the licenses system.
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 5
2.5 Replacement Options
If you want to transfer a PB610 project form a today´s CP635, CP651 or CP676, which have direct successors in CP600 2nd generation (CP6407, CP6410,
CP6415), you will face no difference in screen size and resolution, means, your current application will fit for the successor screen without any borders or other
mismatches. If you want to replace a today´s CP620, CP630, CP661, CP665, which don´t have direct successors in CP600 2nd generation, screen sizes and
resolutions might be different. In that even after optimal adaption of the PB610 application some borders will remain on the new target control panel.
current
panel
size resolution replacement size resolution factor borders cutout interfaces
CP620 4.3” 480x272 CP604 4.3“ 480x272 1.000 no same -1xETH, -SD
CP6605 5“ 800x480 1.667 13 px up+down same same
CP630 5.7” 320x240 CP6407 7“ 800x480 2.000 80 px left+right same same
CP635 7” 800x480 CP6407 7“ 800x480 1.000 no same same
CP607 7“ 800x480 1.000 no same -1xETH, -SD
CP6607 7“ 800x480 1.000 no same +1xETH
CP651 10.4” 800x600 CP6410 10.4“ 800x600 1.000 no same same
CP661 12.1” 800x600 CP6415 15“ 1024x768 1.280 no bigger same
CP665 13.3” 1280x800 CP6615 15.6“ 1366x768 0.960 69 px left+right wider +1xETH
CP676 15” 1024x768 CP6415 15“ 1024x768 1.000 no same same
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 6
3 Convert Application
3.1 Update Project or new Project
Update Project can be done by “Project Properties” in the section “Project -> Project Type”
(see chapter Convert Project with Panel Builder)
• Target HMI will be changed
• Standard application will be transferred
3.2 Convert Project with Panel Builder with same screen
size
• Create backup of your current Panel Builder project
• Open existing project with Panel Builder in version V2.8.1.447 or newer
• You will be asked if you want to update the project
• Confirm with “Convert”
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 7
• Double Click “Project Properties”
• Expand the Project entry and select Project Type
• Push Button right to “+” Button
• Select the matching target, the table is shown in chapter 2.5 Replacement Options
• Confirm with Finish
• A hint will be shown, that the target will be changed
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 8
• Confirm with Yes
CAUTION!
If IRC5 driver is used, it has to be replaced by IRC5 Linux driver with relevant
configuration parameters.
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 9
3.3 Convert Project with Panel Builder with different
screen size
• Create backup of your current Panel Builder project
• Open existing project with Panel Builder in version V2.8.1.447 or newer
• You will be asked if you want to update the project
• Confirm with “Convert”
• Double Click “Project Properties”
• Expand the Project entry and select Project Type
• Push Button right to “+” Button
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 10
• Select the matching target, the table is shown in chapter 2.5 Replacement Options
• Confirm with Finish
• A hint will be shown, that the resolution of the new target is different. Quadruple res-
olution of the application, adapted from CP630 800x480 pixels instead of former
320x240 pixels
• Select all three checkboxes (Keep page size, Keep Keyboard templates and Keep Us-
ermanagement templates) and confirm with Yes
CP600 CONVERTING A CP600 P ROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 11
• Some additional parameters must be adapted. Please enable the Show Advances
properties button in the upper left corner
• Set the parameters as seen in the screenshot below
o Current target device (here: project type) „CP630“ has to be replaced by
„CP6407“
o Checking the box Keep page size, Keep Keyboard templates and Keep Us-
ermanagement templates will make sure, that current application can just be
zoomed correctly
o PageWidth and PageHeight represent the resolution of the target device and
are updated automatically with the selection of CP6407
o Target zoom factor: It shall be defined in that way, that at least one - either
the horizontal or the vertical - resolution meets the equivalent resolution of
the new target device.
In this example – target zoom factor: 2 ➔ 2x (320x240) ➔ 640x480 (see table
in chapter 2.5)
▪ the zoomed vertical resolution complies with the vertical resolution
of the new CP6407
▪ The zoomed horizontal resolution of 640 is by 160 less than 800 of
the new CP6407 ➔ Since the application is displayed with central
alignment there will be two stripes (width of 80 pixels each) of back-
ground left and right on the CP6407
o Background color: This option defines the color of the borders, which will be
visible on the panels screen left and right from the presentation of the appli-
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 12
cation. In this example blue color was selected for better visibility of the bor-
ders. In real applications black background color [0, 0, 0] might be the best
solution.
• A further parameter must be adapted. Please switch to your first page in the project.
There we have to adapt one parameter.
• Set the parameter as seen in the screenshot below for each page
o Please set the parameter Static Optimization to false. This will enable ren-
dering during runtime.
CP600 CONVERTING A CP600 PROJECT TO A CP600 2ND GENERATION PROJECT
3ADR010541, 2, en_US 13
• The result from the above settings:
CAUTION!
If IRC5 driver is used, it has to be replaced by IRC5 Linux driver with relevant
configuration parameters.
CP630
same application size on screen
CP6407: double resolution
stripes of background
color left and right
CP6407
__
__
ABB Automation Products GmbH
Eppelheimer Straße 82
69123 Heidelberg, Germany
Phone: +49 62 21 701 1444
Fax: +49 62 21 701 1382
E-Mail: [email protected]
www.abb.com/plc
We reserve the right to make technical
changes or modify the contents of this
document without prior notice. With re-
gard to purchase orders, the agreed par-
ticulars shall prevail. ABB AG does not ac-
cept any responsibility whatsoever for
potential errors or possible lack of infor-
mation in this document.
We reserve all rights in this document and
in the subject matter and illustrations con-
tained therein. Any reproduction, disclo-
sure to third parties or utilization of its
contents – in whole or in parts – is forbid-
den without prior written consent of ABB
AG.
Copyright© 2020 ABB. All rights reserved