128
1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule Volume II, Part C Tech Spec No. - PE-TS-401- 999- E001; Rev.0 PRICE SCHEDULE

Cover Page- Separators - NBPPL · PDF fileNOTES 4. Transit Insurance ... earthing & lightning protection systems ... Networking and Harware for Numerical relay:As per annexure‐2F

Embed Size (px)

Citation preview

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

PRICE SCHEDULE

SL. No.DESCRIPTIONS OF WORKS OR EQUIPMENT

Total Quoted Price

1 2 31.0

TECHNICAL SPECIFICATION NO: PE-TS-401-999-E001, Rev. 0

TITLE: PRICE SCHEDULE Volume-II, Part-C

PACKAGE: - ELECTRICAL SYSTEM

Total firm price on “FOR” site basis for DESIGN, MANUFACTURE, INSPECTION AND TESTING AT MANUFACTURER'S WORKS, PROPER PACKING AND DELIVERY TO SITE, STORAGE AT SITE, HANDLING, TRANSPORTATION OF MATERIALS FROM PROJECT STORAGE YARD / STORES TO ERECTION SITE / PLACE OF ERECTION , STORAGE AT ERECTION SITE, PRESERVATION, WATCH AND WARD, DRESSING, CHIPPING AND LEVELLING OF FOUNDATIONS, CLEANING , CHECKING, TESTING, PRE-ASSEMBLY, ERECTION, CALIBRATION, ALIGNMENT, WELDING, WHEREVER REQUIRED, PRESERVATIVE/ TOUCH-UP PAINTING INCLUDING SUPPLY OF PAINTS ETC, EARTHING OF EQUIPMENT, INCLUDING OTHER ACTIVITIES REQUIRED FOR ERECTION, TESTING, COMMISSIONING, POST COMMISSIONING, TRIAL OPERATIONS & HANDING OVER OF ALL ELECTRICAL EQUIPMENTS AND ITEMS AS PER BOQ INCLUDING SUPPLY OF MANDATORY SPARES, RECOMMENDED SPARES, SPECIAL TOOLS & TACKLES FOR MAINTENANCE ,START-UP ,PRE COMMISSIONING & COMMISSIONING SPARES AS SPECIFIED & AS NECESSARY FOR COMPLETENESS IN ALL RESPECTS AND FOR EFFICIENT & TROUBLE FREE OPERATION OF ELECTRICAL SYSTEMS PACKAGE FOR FEROZE GANDHI UNCHAHAR THERMAL POWER PROJECT – STAGE IV (1 X 500 MW) AS PER

PROJECT : - 1 X 500 MW FGUTPP, UP (Stage - IV)

NOTES

4.Transit Insurance shall be in NBPPL Scope .

FEROZE GANDHI UNCHAHAR THERMAL POWER PROJECT – STAGE IV, (1 X 500 MW) AS PER TECHNICAL SPECIFICATION NO:PE-TS-401-999-E001, Rev. 0 namely - 11kV & 3.3kV segregated phase busduct- MV switchgear- Low voltage switchgear,LT bus duct & neutral grounding resistor (NGR)- Cabling, earthing & lightning protection systems- Fire sealing system- HT XLPE Cables- 1.1kV XLPE Power, PVC PowerCables- 1.1kV PVC Control Cables- Screened Control Cables- 220V DC Battery- 220V DC Battery Charger- Generator Circuit Breaker- Public Address System- Dry Type Transformers- Oil Filled Service Transformer - Emergency D.G. Set- EPABX system- Electrical Equipment Handling Arrangement

5. Any other items, if required to be included is in bidder's scope apart from the above, same shall be included in the respective items itself & no separate price shall be quoted.

6. The above items shall be quoted as per tender specification. Responsibility of ensuring correctness & completeness of scope of supply as per specification requirement solely lies with bidder. 7.Bidder shall furnish the Breakup Prices in Annexures attached with this Price Schedule only

1. L1 bidder shall be evaluated based on the Total Price under column 3 S.No. 1.0 and hence bidder prices should be complete in all respects for the full scope defined considering all terms and conditions agreed . 2. Bidder to furnish list of items as recommended spares for 3 years with its price breakup. Prices of Recommended Spares will be optional and not be considered for evaluation.

3.Bidder to fill all Optional Price Schedule Annexures attached with this Price Schedule

1 of 1

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

1. 11 kV AND 3.3 kV SEGREGATED PHASE

BUSDUCT

DESCRIPTION UNIT QTY Unit Ex-works

price/Unit Price

Total Ex-Works Price

duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection &

Commissioning Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices

including Service Tax in

INR

Total Supply and E&C in

INR

11kV, 3000A

LENGTH METER 180

90 deg Bend NOS. 30

TRANSFORMER TERMINATIONS NOS. 3

SWITCHGEAR TERMINATIONS NOS. 6

TEE CONNECTION NOS. 1

WALL FRAME ASSEMBLY NOS. 3

TOTAL PRICE

3.3kV, 3000A

LENGTH METER 90

90 deg Bend NOS. 12

TRANSFORMER TERMINATIONS NOS. 2

SWITCHGEAR TERMINATIONS NOS. 4

WALL FRAME ASSEMBLY NOS. 2

TOTAL PRICE

3.3kV, 2500A

LENGTH METER 40

90 deg Bend NOS. 4

TRANSFORMER TERMINATIONS NOS. 2

SWITCHGEAR TERMINATIONS NOS. 2

WALL FRAME ASSEMBLY NOS. 2

TOTAL PRICE

Supporting structure (hot dip galvanized MS), foundation channels, hardware etc. Suitable for bus ductelevation and length involved.

As required forcomplete scope

BOQ CUM UNPRICED SCHEDULE OF 11KV & 3.3KV SEGRAGATED PHASE BUSDUCT

ANNEXURE-1

DESCRIPTION UNIT QTY Unit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in

INR on self manufactu

red only

Freight including Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection & Commissi

oning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply

and E&C in INR

11kV, 3000A   

LENGTH  METER  180

90 deg Bend  NOS.  30

TRANSFORMER TERMINATIONS  NOS.  3

SWITCHGEAR TERMINATIONS  NOS.  6

TEE CONNECTION  NOS.  1

WALL FRAME ASSEMBLY  NOS.  3

TOTAL PRICE   

3.3kV, 3000A   

LENGTH  METER  90

90 deg Bend  NOS.  12

TRANSFORMER TERMINATIONS  NOS.  2

SWITCHGEAR TERMINATIONS  NOS.  4

WALL FRAME ASSEMBLY  NOS.  2

TOTAL PRICE   

3.3kV, 2500A   

LENGTH  METER  40

90 deg Bend  NOS.  4

TRANSFORMER TERMINATIONS  NOS.  2

SWITCHGEAR TERMINATIONS  NOS.  2

WALL FRAME ASSEMBLY  NOS.  2

TOTAL PRICE   

ANNEXURE-1

BOQ for Erection & Commissioning of 11KV & 3.3KV SEGRAGATED PHASE BUSDUCT

 Supporting structure (hot dip galvanized MS), foundation channels, hardware etc. Suitable for bus duct

elevation and length involved.

As required for

complete scope

S.no. Item Description Quantity

Unit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including cess on E &

C in INR

Total E & C prices

including Service Tax

in INR

Total Supply and E&C in

INR

A 11 kV Busduct

1 Support insulators 25 Nos.

2 Three phase set of flexible terminal connectors for switchgear end of each type & rating 1 Set

3 Three phase set of flexible terminal connector for transformer end of each type & rating 1 Set

4 Seal off bushings of each type & rating 3 Nos.

B 3.3 kV Busduct

1 Support insulators 25 Nos.

2 Three phase set of flexible terminal connectors for switchgear end of each type & rating 1 Set

3 Three phase set of flexible terminal connector for transformer end of each type & rating 1 Set

4 Seal off bushings of each type & rating 3 Nos.

MANDATORY SPARES FOR MV BusductANNEXURE-1

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

2. MV SWITCHGEAR

S.no Description UOM Quantity Rating (A)

Unit Ex‐works 

price/Unit 

Price

Total Ex‐Works 

Price duly packed 

in INR/Total Price. 

Excise Duty 

@ on self 

manufactur

ed only

VAT/CST @ 

… in INR on 

self 

manufactur

ed only

Freight 

including 

Service tax 

@

Total FOR 

Site Price 

(Supply)  in 

INR 

Total 

Erection & 

Commission

ing Charges  

INR

Service tax 

@ including 

cess  on E & 

C  in INR

Total E & C 

prices 

including 

Service Tax  

in INR

Total 

Supply and  

E&C  in INR

1 11 kV Unit Switchboard#6BA Nos. 1 3000A

2 11 kV Unit Switchboard#6BB Nos. 1 3000A

3 11 kV Standby Switchboard#0BA Nos. 1 3000A

4 11 kV Colony Switchboard Nos. 1 630A

5 3.3 kV Unit Aux. Switchboard#6CA Nos. 1 3000A

6 3.3 kV Misc. Aux. Switchboard#0CA Nos. 1 2500A

7 Site modification charges:As per annexure‐2C Nos. 1

8 Mandatory Spares:As per annexure‐2D SET 1

9 Data Concetrator system:As per annexure‐2ENos. 1

10Networking and Harware for Numerical relay:As 

per annexure‐2F Nos. 1

11  Training Requirement Annexure‐2G SET 1

12Erection & commissioning charges:As per 

anenexure‐2H Nos.1

Notes.

1

3

4

5

6

7

8

9

10

11

12

13

a)

b)

c)

14

15

16

Minimum clearances required on all sides for each type of panel

Mandatory Spares:As per annexure‐2D

Addition/deletion of quantities shall be aplicable at the quoted prices.The Unit rate of supply of all 

equipments and services quoted by the bidders shall be frim.Requirement of feeders for various 11kV & 

3.3kV switchboards is enclosed in Annexure ‐B. Adopter panels for cable/bus duct connections as 

necessary shall be included by Bidder.

The 3.3 kV boards 6CA and 0CA shall be split into two section due to layout requirements. The cost of tie 

breaker to achieve this shall be included in switchboard price. Please refer MV SWGR layout.

List of MV Boards

For detailed panel wise and board wise BOM and Schedule of Unit Prices, refer Annexure‐2B

Site modification charges:As per annexure‐2C

1X500 MW FGUTPP

BOQ CUM PRICE SCHEDULE OF MV SWGR (Supply) Annexure‐2

Data Concetrator system:As per annexure‐2E

Networking and Harware for Numerical relay:As per annexure‐2F

 Training Requirement Annexure‐2G

List of make (Sub vendor items) is subject to customer approval  during contract stage without any price 

implication

Commissioning charges of numerical relays & data concentrator shall be included in the price quoted for 

SWGR & no extra chrges will be given for the same

All motors and dry type transformer feeders shall be provided with surge suppressors

Tinned brass, double compression type complete with necessary armour clamp cable glands and lugs for 

power & control cables for all external connections to MV switchboards.

Multifunction numerical relays with communication facility on protocol IEC‐61850 shall be selected to 

provide an integrated protection, control, monitoring and metering functions.Features such as self 

diagnosis and external testing, disturbance recording, sequence of event recording and time stampings 

shall be available with relay. Relays shall be of proven design & reputed make subject to customer 

approval during contract stage without any price implication.Bidder to specifically ensure inclusion of 

required hardware/software.

Unit rates quoted in Annexure‐2B,2C,2D,2E,2F and 2G shall be used for any addition/deletion during 

detailed engineering.

Following information other than those asked in the different parts of specification shall be furnished 

along with bid 

Complete dimensions of all the boards including number of panels

Dimension of each type of panel

Board  11kV unit Switchboard#6BA

Rating 3000A

S.no Feeder Description Rating Module Type Quantity (Nos.) Unit Ex‐works price/Unit PriceTotal Ex‐Works Price duly 

packed in INR/Total Price. 

Excise Duty @ on 

self manufactured 

only

VAT/CST @ … in 

INR on self 

manufactured 

only

Freight including 

Service tax @

Total FOR Site 

Price (Supply)  in 

INR 

Total Erection & 

Commissioning 

Charges  INR

Service tax @ 

including cess  on 

E & C  in INR

Total E & C prices 

including Service 

Tax  in INR

Total Supply and  

E&C  in INR

1 Incomer from UT#6A 3000A DC 1

2 Line PT ‐‐‐‐‐‐ 2

3 Bus PT ‐‐‐‐‐‐ G 1

4 Tie from Standby Switchboard#0BA 3000A DE 1

5 UAT#6CAT01 16MVA DBF 1

6 Misc Aux. Trf#0CAT01 12.5MVA DBF 1

7 CHP Trf. #0CBT01 5MVA DBF 1

8 AHP Trf. #0CCT01 5MVA DBF 1

9 Spare Trf. feeder 16 MVA DBF 1

10 MD BFP#6 10000 KW DAF 1

11 CWP#6A 2300KW DAF 1

12 PA FAN#6A 3250KW DAF 1

13 FD FAN#6A 1350KW DA 1

14 CEP#6A 900KW DA 1

15 VFD ID FAN#6A(CH1) 3900KW DBF 1

16 VFD ID FAN#6A(CH2) 3900KW DBF 1

17 Spare Motor feeder 10000 KW DAF 1

18 Dummy panel 1

19 Adopter Panel  1

Board  11kV unit Switchboard#6BB

Rating 3000A

S.no Feeder Description Rating Module Type Quantity (Nos.) Unit Ex‐works price/Unit PriceTotal Ex‐Works Price duly 

packed in INR/Total Price. 

Excise Duty @ on 

self manufactured 

only

VAT/CST @ … in 

INR on self 

manufactured 

only

Freight including 

Service tax @

Total FOR Site 

Price (Supply)  in 

INR 

Total Erection & 

Commissioning 

Charges  INR

Service tax @ 

including cess  on 

E & C  in INR

Total E & C prices 

including Service 

Tax  in INR

Total Supply and  

E&C  in INR

1 Incomer from UT#6B 3000A DC 1

2 Line PT ‐‐‐‐‐‐ 2

3 Bus PT ‐‐‐‐‐‐ G 1

4 Tie from Standby Switchboard#0BA 3000A DE 1

5 UAT#6CAT02 16MVA DBF 1

6 Misc Aux. Trf#0CAT02 12.5MVA DBF 1

7 CHP Trf. #0CBT02 5MVA DBF 1

8 AHP Trf. #0CCT02 5MVA DBF 1

9 Spare Trf. feeder 5 MVA DBF 1

10 CWP#6B 2300KW DAF 1

11 CWP#6C 2300KW DAF 1

12 PA FAN#6B 3250KW DAF 1

13 FD FAN#6B 1350KW DA 1

14 CEP#6B 900KW DA 1

15 CEP#6C 900KW DA 1

16 VFD ID FAN#6B(CH1) 3900KW DBF 1

17 VFD ID FAN#6B(CH2) 3900KW DBF 1

18 Spare Motor feeder 3250 KW DAF 1

19 Dummy panel 1

20 Adopter Panel  1

1X500 MW FGUTPP

Annexure ‐2B ( Board Wise BOM & Schedule of Unit Prices for various 11kV & 3.3kV switchboards )

Board  11kV Standby Switchboard#0BA

Rating 3000A

S.no Feeder Description Rating Module Type Quantity (Nos.) Unit Ex‐works price/Unit PriceTotal Ex‐Works Price duly 

packed in INR/Total Price. 

Excise Duty @ on 

self manufactured 

only

VAT/CST @ … in 

INR on self 

manufactured 

only

Freight including 

Service tax @

Total FOR Site 

Price (Supply)  in 

INR 

Total Erection & 

Commissioning 

Charges  INR

Service tax @ 

including cess  on 

E & C  in INR

Total E & C prices 

including Service 

Tax  in INR

Total Supply and  

E&C  in INR

1 Incomer from ST#0BAT01 3000A DC 1

2 Line PT ‐‐‐‐‐‐ 2

3 Bus PT ‐‐‐‐‐‐ G 1

4 Tie to Unit Switchboard#6BA/6BB 3000A DE 1

5 Adopter Panel  1

Board  11kV Colony Switchboard#0BA

Rating

S.no Feeder Description Rating Module Type Quantity (Nos.) Unit Ex‐works price/Unit PriceTotal Ex‐Works Price duly 

packed in INR/Total Price. 

Excise Duty @ on 

self manufactured 

only

VAT/CST @ … in 

INR on self 

manufactured 

only

Freight including 

Service tax @

Total FOR Site 

Price (Supply)  in 

INR 

Total Erection & 

Commissioning 

Charges  INR

Service tax @ 

including cess  on 

E & C  in INR

Total E & C prices 

including Service 

Tax  in INR

Total Supply and  

E&C  in INR

1 Incomer from ST#0BAT01 630A DC 1

2 Line PT‐A ‐‐‐‐‐‐ 1

3 Bus PT‐A ‐‐‐‐‐‐ G 1

4 TRF. feeder‐1 2MVA DB 1

5 TRF. feeder‐2 2MVA DB 1

6 TRF. feeder‐3 2MVA DB 1

7 B/C 630A 1

8 Line PT‐B ‐‐‐‐‐‐ 1

9 Bus PT‐B ‐‐‐‐‐‐ G 1

10 TRF. feeder‐2 2MVA DB 1

11 TRF. feeder‐3 2MVA DB 1

12 TRF. feeder‐4 2MVA DB 1

13 Dummy panel 1

14 Adopter Panel  1

Board  3.3kV Unit Switchboard#6CA

Rating 3000A

S.no Feeder Description Rating Module Type Quantity (Nos.) Unit Ex‐works price/Unit PriceTotal Ex‐Works Price duly 

packed in INR/Total Price. 

Excise Duty @ on 

self manufactured 

only

VAT/CST @ … in 

INR on self 

manufactured 

only

Freight including 

Service tax @

Total FOR Site 

Price (Supply)  in 

INR 

Total Erection & 

Commissioning 

Charges  INR

Service tax @ 

including cess  on 

E & C  in INR

Total E & C prices 

including Service 

Tax  in INR

Total Supply and  

E&C  in INR

1 Incomer from UAT#6CAT01 3000A DC 1

2 Line PT‐A ‐‐‐‐‐‐ 1

3 Bus PT‐A ‐‐‐‐‐‐ G 1

4 Unit Service Trf.#6DAT01 2000KVA DB 1

5 Station Service Trf.#0DAT01 2000KVA DB 1

6 Fuel Oil Trf.#0DBT01 2000KVA DB 1

7 Service Building  Trf.#0DCT01 1600KVA DB 1

8 SWYD TRF.‐1 630KVA DB 1

9 Spare Trf. feeder 2000KVA DB 1

10 SA Compressor#6A 350KW DA 1

11 MILL MOTOR#6A 525KW DA 1

12 MILL MOTOR#6C 525KW DA 1

13 MILL MOTOR#6E 525KW DA 1

14 MILL MOTOR#6G 525KW DA 1

15 MILL MOTOR#6I 525KW DA 1

16 BCW PUMP#6A 350KW DA 1

17 ACW PUMP#6A 200KW DA 1

18 ACW PUMP#6C 200KW DA 1

19 ECW PUMP(TG)#6A 180KW DA 1

20 ECW PUMP(SG)#6A 180KW DA 1

21 Spare Motor feeder 525KW DA 1

22 B/C 3000A DD 1

23 Incomer from UAT#6CAT02 3000A DC 1

24 Line PT‐B ‐‐‐‐‐‐ 1

25 Bus PT‐B ‐‐‐‐‐‐ G 1

26 Unit Service Trf.#6DAT02 2000KVA DB 1

27 Station Service Trf.#0DAT02 2000KVA DB 1

28 Fuel Oil Trf.#0DBT02 2000KVA DB 1

29 Service Building  Trf.#0DCT02 1600KVA DB 1

30 SWYD TRF.‐1 630KVA DB 1

31 Spare Trf. feeder 1600KVA DB 1

32 MILL MOTOR#6B 525KW DA 1

33 MILL MOTOR#6D 525KW DA 1

34 MILL MOTOR#6F 525KW DA 1

35 MILL MOTOR#6H 525KW DA 1

36 MILL MOTOR#6J 525KW DA 1

37 BCW PUMP #6B 350KW DA 1

38 BCW PUMP #6C 350KW DA 1

39 IA Compressor#6A 350KW DA 1

40 ACW PUMP#6B 200KW DA 1

41 ECW PUMP(TG)#6B 180KW DA 1

42 ECW PUMP(TG)#6C 180KW DA 1

43 ECW PUMP(SG)#6B 180KW DA 1

44 Spare Motor feeder 350KW DA 1

45 Dummy panel 1

46 Adopter Panel  1

Board  3.3kV Misc. Aux. Switchboard#0CA

Rating 2500A

S.no Feeder Description Rating Module Type Quantity (Nos.) Unit Ex‐works price/Unit PriceTotal Ex‐Works Price duly 

packed in INR/Total Price. 

Excise Duty @ on 

self manufactured 

only

VAT/CST @ … in 

INR on self 

manufactured 

only

Freight including 

Service tax @

Total FOR Site 

Price (Supply)  in 

INR 

Total Erection & 

Commissioning 

Charges  INR

Service tax @ 

including cess  on 

E & C  in INR

Total E & C prices 

including Service 

Tax  in INR

Total Supply and  

E&C  in INR

1 Incomer from Misc. Aux. Trf.#0CAT01 2500A DC 1

2 Line PT‐A ‐‐‐‐‐‐ 1

3 Bus PT‐A ‐‐‐‐‐‐ G 1

4 ESP Service Trf.#6DCT01 1600KVA DB 1

5 ESP Service Trf.#6DDT01 1600KVA DB 1

6 ESP Service Trf.#6DET01 1600KVA DB 1

7 ESP Service Trf.#6DFT01 1600KVA DB 1

8 Make Up Water Trf.#0DET01 630KVA DB 1

9 Fire water/WTP Trf.#0DDT01 2000KVA DB 1

10 Cooling Tower Trf.#6DBT01 2000KVA DB 1

11 Spare Trf. feeder 2000KVA DB 1

12 CW M/U PUMP#A 180KW DA 1

13 Hydrant Main Pump#A 200KW DA 1

14 Spray Pump#A 200KW DA 1

15 Raw Water M/U Motor#A 450KW DA 1

16 APH wash M/U Pump#A 225KW DA 1

17 Spare Motor feeder 450KW DA 1

18 B/C 2500A DD 1

19 Incomer from Misc. Aux. Trf.#0CAT02 2500A DC 1

20 Line PT‐B ‐‐‐‐‐‐ 1

21 Bus PT‐B ‐‐‐‐‐‐ G 1

22 ESP Service Trf.#6DCT02 1600KVA DB 1

23 ESP Service Trf.#6DDT02 1600KVA DB 1

24 ESP Service Trf.#6DET02 1600KVA DB 1

25 ESP Service Trf.#6DFT02 1600KVA DB 1

26 Make Up Water Trf.#0DET02 630KVA DB 1

27 Fire water/WTP Trf.#0DDT02 2000KVA DB 1

28 Cooling Tower Trf.#6DBT02 2000KVA DB 1

29 Spare Trf. feeder 1600KVA DB 1

30 CW M/U PUMP#B 180KW DA 1

31 Hydrant Main Pump#B 200KW DA 1

32 Hydrant Main Pump#C 200KW DA 1

33 Raw Water M/U Motor#B 450KW DA 1

34 APH wash M/U Pump#B 225KW DA 1

35 Spare Motor feeder 350KW DA 1

36 Dummy panel 2nos. 1

37 Adopter Panel  1

S.no Description UOM Rating (A)Unit Ex‐works price/Unit 

Price

Total Ex‐Works Price duly 

packed in INR/Total Price. 

Excise Duty including cess  

@ ……Rs 

VAT/CST @ … in 

INR on self 

manufactured 

only

Freight including 

Service tax @

Total FOR Site 

Price (Supply)  in 

INR 

Total Erection & 

Commissioning 

Charges  INR

Service tax @ 

including cess  on 

E & C  in INR

Total E & C prices 

including Service 

Tax  in INR

Total Supply and  

E&C  in INR

1 11 kV Unit Switchboard#6BA 1Set 3000A

2 11 kV Unit Switchboard#6BB 1Set 3000A

3 11 kV Standby Switchboard#0BA 1Set 3000A

4 11 kV Colony Switchboard 1Set 630A

5 3.3 kV Unit Aux. Switchboard#6CA 1Set 3000A

6 3.3 kV Misc. Aux. Switchboard#0CA 1Set 2500A

Note: One set means one earthing truck suitable for all types of panels in that switchboard suitable for busbar side and cable side in that board / boards OR mulitple earthing trucks, one for each type of panel suitable for cable side earthing and independent truck for busbar side earthing in that board / boards.

BOQ for Earthing Trucks (If applicable)

The bidder shall bring out clearly in his bid the requirements of earthing trucks for the panels covered in this package

SL.NO. DETAILS QUANTITY Unit Charges in INR

Total Ex‐Works 

Price duly packed 

in INR/Total 

Price. 

Excise Duty @ on self 

manufactured only

VAT/CST @ … in INR 

on self manufactured 

only

Freight including 

Service tax @

Total FOR Site Price 

(Supply)  in INR 

(6+7+8+9)

Total Charges in  INR

Service tax @ 

including cess  on Total 

Charges  in INR

Total Charges 

including Service Tax  

in INR

1 LUMP SUM ALL INCLUSIVE CHARGES PER VISIT FOR 

SKILLED TECHNICIAN (EXCEPT DAILY CHARGES)

3 VISITS

2 LUMP SUM ALL INCLUSIVE DAILY CHARGES FOR SKILLED 

TECHNICIAN 

20 DAYS

3 LUMP SUM ALL INCLUSIVE CHARGES PER VISIT FOR 

SERVICE ENGINEER (EXCEPT DAILY CHARGES)

3 VISITS

4 LUMP SUM ALL INCLUSIVE DAILY CHARGES FOR SERVICE 

ENGINEER 

15 DAYS

NOTES:  

1) 

2)  AMOUNT PAYABLE FOR SERVICE ENGINEER PER VISIT TO SITE = VISIT CHARGES AS PER SL. NO. 3 ABOVE  + 

(DAILY CHARGES AS PER SL. NO. 4 ABOVE  X  NO. OF DAYS AT SITE) (TO BE CERTIFIED BY SITE)

AMOUNT PAYABLE FOR SKILLED TECHNICIAN PER VISIT TO SITE = VISIT CHARGES AS PER SL. NO. 1 ABOVE  + 

(DAILY CHARGES AS PER SL. NO. 2 ABOVE  X  NO. OF DAYS AT SITE) (TO BE CERTIFIED BY  SITE)

1X500 MW FGUTPP

SITE MODIFICATION CHARGES (Annexure‐2C)

S.no. Item Description Quantity Unit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on

E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

11 KV/3.3KV SWITCHGEARS 1 Breaker of each rating 1 No. 2 Numerical relays 2 Nos. of each type

3Aux. Relays/ Lock out relays/ Timers(if applicable) 2 Nos. of each type

4 Bus bar support insulators 12 Nos. 5 Energy meter of each type & range 1 No. of each type 6 Spring charging motor complete 2 Nos. of each type.

7 Current transformer of each type & ratio 3 Nos. of each type

8 Potential transformer of each type & ratio 3 Nos. of each type 9 Shunt trip coil 5 Nos. of each type & rating

10 Closing coils 5 Nos. of each type & rating

11

Moving contact assembly of each rating (One set means complete replacement for one breaker) 2 Sets

12

Stationary (fixed contact of each rating.(One set means complete replacement for one breaker) 2 Sets

13 Bus seal off bushings 3 Nos. of each type & size 14 Limit switches 10 Nos. 15 Control switches 2 Nos. of each type 16 Selector switches 2 Nos. of each type 17 Isolation switch for the control supply 2 Nos.

18 Circuit breaker auxiliary contact assembly 6 Nos. of each type & rating 19 Indicating lamps with holders 20 Sets 20 (a) Fuse base and holder 12 Nos.

(b) Fuse link 12 Nos.

21

Isolating contact ( fixed & moving)( one set means male & female contacts of one complete breaker) 4 Sets of each rating

22 Terminal blocks 6 Nos.

23SF6 cylinder with SF6 gas filled alongwith nozzle for filling the gas(if applicable) 3 Nos.

24Multiple pin plug contact assy. with cables (male & female) 6 Nos.

25 Interphase barrier 2 Nos. of each type 26 Pressure gauge ( for SF6 breakers) 2 Nos. 27 Vacuum Contactors with HRC fuses 2 Sets (One set for three phases) 28 Surge arresters 3 Nos.

29Modules for Data Concentrator & system LAN 1 No. module of each type

1X500 MW FGUTPPAnnexure-2D LIST OF MANDATORY SPARES FOR 11KV/3.3KV SWITCHGEARS

Sl. No. ITEM DESCRIPTION QUANTITYUnit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection &

Commissioning Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices

including Service Tax in

INR

Total Supply and E&C in

INR

1DATA CONCENTRATOR ALONGWITH ALL ACCESSORIES FOR COMPLETENESS OF SYSTEM

2 SETS

3 LASER PRINTER (A4 SIZE) 1 NOS.

Notes

a

b

1X500 MW FGUTPPData Concetrator system: Annexure-2E

2 HMI 2 SETS

For other details bidder to refer architecture for Networking of Numerical relays (drawung no 0000-205-POE-A-001) and specification.

All above items shall be supplied along with accessories (including special tools for installation) required for completeness of system.

Sl. No. ITEM DESCRIPTION QUANTITYUnit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on

E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

a Ethernet Switch on IEC61850 with 8 Copper ports and 4 Gigabit FO ports 15

b Ethernet Switch on IEC61850 with 16 Copper ports and 4 Gigabit FO ports 20

2FIBER OPTICAL CABLE FOR COMMUNICATION (INCLUSIVE OFSUPPLY, LAYING AND TERMINATION ALONGWITH ANYHARDWARE REQUIRE AT EQUIPMENT SUPPLIED UNDER THISPACKAGE) 8 Km

3 LAPTOP PC WITH LICENCED VERSION SOFTWARE, HARDWARE ALONGWITH CONNECTING CABLES FOR RELAY PARAMETERISATION 1 No

4 Cat5E Ethernet cable for connection of Relays to Ethernet Switches 2 Km

5 Additional Numerical relays for Owner's requirement (for Module type DC) 2 Nos

6 Additional Numerical relays for Owner's requirement (for Module type DAF) 2 Nos

7 Additional Numerical relays for Owner's requirement (for Module type DBF) 2 Nos

8

COMMISSIONING CHARGES FOR CABLE LAYING FROM RELAY TO ETHERNET SWITCH AND ETHERNET SWITCH TO DATA CONCENTRATOR /ETHERNET SWITCH TO MV SYSTEM. AND FOR CABLE LAYING FROM ETHERNET SWITCH TO DATA CONCENTRATOR TO LV SYSTEM.

LOT

Notes

a

b

1

STAR COUPLER/EATHERNET SWITCH/ EQUIVALENT DEVICEWITH IEC-61850 PROTOCOL AND 100% REDUNDANT I/OTERMINALS FOR COMUNICATION BETWEEN RELAYS AND DATACONCENTRATOR/ GATEWAY CONCENTRATOR AS PER SYSTEMREQUIREMENT

For other details bidder to refer architecture for Networking of Numerical relays (drawung no 0000-205-POE-A-001) and specification.

All above items shall be supplied along with accessories (including special tools for installation) required for completeness of system.

1X500 MW FGUTPP

Annexure-2F (Networking and Harware for Numerical relay)

Item No. DESCRIPTION  UOM Unit Charges  in INR

Total Ex‐Works 

Price duly packed 

in INR/Total Price. 

Excise Duty @ on 

self manufactured 

only

VAT/CST @ … in 

INR on self 

manufactured 

only

Freight including 

Service tax @

Total FOR Site 

Price (Supply)  in 

INR 

Total  Charges  in 

INR

Service tax @ 

including cess  on 

Total Charges  in 

INR

Total 

Chargesincluding 

Service Tax  in INR

Training of Engineers:

a) Basic cost [irrespective of no. 

of engineers]

b) Additional variable cost per 

engineer

1 1 Set

1X500 MW FGUTPP

Annexure‐2G Training Requirement

S.no Description UOM Quantity Rating (A)

Unit Erection 

Commissioni

ng Charges  

in INR

Total Ex‐Works 

Price duly 

packed in 

INR/Total Price. 

Excise Duty @ 

on self 

manufactured 

only

VAT/CST @ … 

in INR on self 

manufactured 

only

Freight 

including 

Service tax @

Total FOR Site 

Price (Supply)  

in INR 

Total Erection 

Commissioning 

Charges  INR

Service tax @ 

including cess  

on E & C  in INR

Total E & C 

prices including 

Service Tax in 

INR

Total Supply 

and  E&C  in 

INR

1 11 kV Unit Switchboard#6BANos.

13000A

2 11 kV Unit Switchboard#6BBNos.

13000A

3 11 kV Standby Switchboard#0BANos.

13000A

4 11 kV Colony SwitchboardNos.

1630A

5 3.3 kV Unit Aux. Switchboard#6CANos.

13000A

6 3.3 kV Misc. Aux. Switchboard#0CANos.

12500A

BOQ CUM PRICE SCHEDULE FOR ERECTION & COMMISSIONING OF MV SWGR ANNEXURE‐2H

1X500 MW FGUTPP

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

3. LV SWITCHGEAR, LT

BUSDUCT, NGR

1X500 MW UCHAHAR FGTPS (UNIT-6) SUPPLY BOM FOR LV SWITCHGEAR,LT BUS DUCT AND NGR ANNEXURE-3A

RATING(A) BOARD NO.

1 UNIT SERVICE SWBD. NOS. 1 3200 A 6DA2 BOILER MCC NOS. 1 1000 A 6HA3 TURBINE MCC NOS. 1 1000 A 6KA4 BOILER V&D MCC NOS. 1 250 A 6HB5 TURBINE VALVE MCC NOS. 1 250 A 6KB6 UNIT SERVICE ACDB. NOS. 1 630 A 6QA7 BOILER ACDB. NOS. 1 630 A 6HC8 UNIT EMERGENCY SWBD NOS. 1 2500 A 6DG9 ESP-1 LT MAIN SWITCH BOARD NOS. 1 3200 A 6DC

10 ESP-2 LT MAIN SWITCH BOARD NOS. 1 3200 A 6DD11 ESP-3 LT MAIN SWITCH BOARD NOS. 1 3200 A 6DE12 ESP-4 LT MAIN SWITCH BOARD NOS. 1 3200 A 6DF13 ESP A/C & VENT MCC NOS. 1 400 A 6TB14 ESP AREA MCC NOS. 1 250 A 6HD15 COOLING TOWER SWBD NOS. 1 3200 A 6DB16 STATION SERVICE SWBD. NOS. 1 3200 A 0DA17 MISC. SERVICE MCC NOS. 1 630 A 0QA18 VENTILATION MCC NOS. 1 1000 A 6TA19 AIR CONDITIONING MCC NOS. 1 1000 A 0TA20 FIRE WATER/WTP SWBD. NOS. 1 3200 A 0DD21 CHLORINATION PLANT MCC NOS. 1 400 A 0SA22 HYDROGEN & PT PLANT MCC NOS. 1 630 A 0SB23 RO DM PLANT MCC NOS. 1 400 A 0SC24 FUEL OIL SWBD NOS. 1 1600 A 0DB25 MAKE UP WATER SWGR NOS. 1 1000 A 0DE26 SERVICE BUILDING SWGR NOS. 1 2500 A 0DC27 CPU/COMPRESSOR MCC NOS. 1 630 A 0SD28 220V MAIN DCDB NOS. 1 1000A 6FA29 240V AC FUSE DBS NOS. 12 63A 12WAY 1P O/G (16 amp)30 220V FUSE DCDB NOS. 4 50A 12 WAY O/G (10 amp)

31 LT BUSDUCT-3200A SET 4

LT BUSDUCT 3200A, FROM LV TERMINALS OF DRY TYPE TRANSFORMERS TO PCC / PMCC. EACH SET OF 15 M

32 LT BUSDUCT-3200A SET 13

LT BUSDUCT 3200A, FROM LV TERMINALS OF OIL FILLED TRANSFORMERS TO PCC / PMCC. EACH SET OF 4 M

33 LT BUSDUCT-2500A SET 2

LT BUSDUCT 2500A, FROM LV TERMINALS OF OIL FILLED TRANSFORMERS TO PMCC. EACH SET OF 15 M

34 LT BUSDUCT-1600A SET 2

LT BUSDUCT 1600A, FROM LV TERMINALS OF OIL FILLED TYPE TRANSFORMERS TO PMCC. EACH SET OF 15 M

35

EACH SET COMPRISING OF:

FOR DRY TYPE TRANSFORMERS 1) 90 DEG BEND – 2NOS 2) FLEXIBLE (CU) AT TRANSFORMER END – 1SET 3) ADAPTER – 1NO. 4) PHASE CROSSOVER – 1 NO. 5) SET OF HARDWARE AT TRANSFORMER & SWITCHGEAR END 6) EXPANSION JOINT – 1NO.7) WALL FRAME ASSEMBLY – N/A8) SUPPORT STRUCTURE – N/A

FOR OIL FILLED TYPE TRANSFORMERS 1) 90 DEG BEND – 4 NOS 2) FLEXIBLE (CU) AT TRANSFORMER END – 1SET 3) ADAPTER – 1NO. 4) PHASE CROSSOVER – 1NO. 5) SET OF HARDWARE AT TRANSFORMER & SWITCHGEAR END 6) EXPANSION JOINT – 1NO.7) WALL FRAME ASSEMBLY – 1 No.8) SUPPORT STRUCTURE – 200KG

36LOCAL PUSH BUTTON STATIONS TYPE - A NOS. 700

EMERGENCY STOP PUSH BUTTON STATION. 1NO. PRESS TO LOCK & TURN TO RELEASE TYPE EMERGENCY STOP PB WITH 2NO + 2NC CONTACTS WITH SUPPORTING STRUCTURE

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in

INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

Sr.No. ITEM NAME UOM TOTAL QTY.

REMARKS

PAGE 1 OF 4

123
Text Box

1X500 MW UCHAHAR FGTPS (UNIT-6) SUPPLY BOM FOR LV SWITCHGEAR,LT BUS DUCT AND NGR ANNEXURE-3A

37LOCAL PUSH BUTTON STATIONS TYPE - B NOS. 25

START & EMERGENCY STOP PUSH BUTTON STATION .1 NO. START PB & 1NO MUSHROOM HEAD STAYPUT WITH EMERGENCY STOP PB WITH 2NO + 2NC CONTACTS WITH SUPPORTING STRUCTURE

38 LOCAL PUSH BUTTON STATIONS TYPE - C

NOS. 25

FLAME PROOF EMERGENCY STOP PUSH BUTTON STATION. 1NO. PRESS TO LOCK TURN TO RELEASE TYPE EMERGENCY STOP PB WITH 2NO + 2NC

39 LOCAL MOTOR STARTERS 0.37 KW NOS. 5

40 LOCAL MOTOR STARTERS 0.55 KW NOS. 10

41 LOCAL MOTOR STARTERS 0.75 KW NOS. 10

42 LOCAL MOTOR STARTERS 1.10 KW NOS. 25

43 LOCAL MOTOR STARTERS 1.50 KW NOS. 25

44 LOCAL MOTOR STARTERS 2.20 KW NOS. 10

45 LOCAL MOTOR STARTERS 3.70 KW NOS. 5

46 LOCAL MOTOR STARTERS 5.5 KW NOS. 5

47 Numerical Relay LOT 1 of each type

48 NGR 11KV (300A, 10 SEC, 22.163 OHMS)

NOS. 3

49 NGR 3.3KV (300A, 10 SEC, 6.74 OHMS)

NOS. 8

50 TOOLS & TACKLE SET 151 SITE VISIT CHARGES NOS. 152 E & C SPARES SET 1

53 MANDATORY SPARES LOT 1

54 NETWORKING HARDWARE FOR NUMERICAL RELAYS

NOS. 1

55 SITE MODIFICATION MATERIAL LOT 1

NOTES:

AS PER ANNEXURE-DAS PER ANNEXURE- GAS PER ANNEXURE-E1

AS PER ANNEXURE-M

REQUIRED FOR SITE MODIFICATION @ 1% TOTAL EX-WORKS PRICE

AS PER ANNEXURE-E2

ALL NECESSARY SUPPORTING STRUCTURES ARE PART OF NGR

1. ITEM WISE PRICES WITH QUANTITY OF EACH ITEM OF TOOLS & TACKLES AS PER LIST IN ANNEXURE –3D SHALL BE FURNISHED.2. ITEM WISE PRICES WITH QUANTITY OF EACH ITEM OF E & C SPARES AS PER LIST IN ANNEXURE – 3E1 SHALL BE FURNISHED.3. ALL LT PCC/ MCC/ DBs SHALL BE SUPPLIED ALONGWITH THE INTEGRAL BASE FRAMES, FOUNDATION BOLTS, CABLE GLANDS & LUGS AND TOOLS & TACKLES AS MENTIONED IN DIFFERENT SECTIONS. ALSO SEPARATE BASE FRAMES OF ISMC-75 FOR SWITCHGEAR ERECTION (IN ADDITION TO INTEGRAL BASE FRAMES) SHALL BE SUPPLIED LOOSE BY THE BIDDER. ALL FIXING NUTS & BOLTS TOGETHER WITH FOUNDATION BOLTS SHALL ALSO BE SUPPLIED. PRICES FOR THE BASE FRAME SHALL BE BUILT IN THE SWITCHBOARD PRICE.4. SITE MODIFICATION CHARGES AS PER LIST IN ANNEXURE – 3G SHALL BE FURNISHED.5. ITEM WISE PRICES FOR TYPE TESTS CHARGES AS PER LIST IN ANNEXURE -3F SHALL BE FURNISHED.6. ITEM WISE PRICES WITH QUANTITY OF EACH ITEM OF O&M AS PER LIST IN ANNEXURE - E2 SHALL BE FURNISHED. LIST OF RECOMMENDED O&M SPARES FOR 3 YEARS (OPTIONAL) WITH ITEM WISE PRICE & QUANTITY OF EACH ITEM AS RECOMMENDED BY MANUFACTURER SHALL BE FURNISHED IN SCHEDULE OF PRICES ALONGWITH.7. ITEM WISE PRICES WITH DESCRIPTION AND RATING OF EACH ITEM COMPLYING TO LIST FURNISHED IN THE SCHEDULE OF UNIT PRICES IN ANNEXURE - 3H SHALL BE FURNISHED IN SCHEDULE OF UNIT PRICE.

8. ITEM WISE PRICES WITH QUANTITY OF EACH ITEM OF NETWORKING HARDWARE FOR NUMERICAL RELAY (AS PER THE EQUIPMENT DETAILS MENTIONED IN THE REMARKS COLUMN) SHALL BE FURNISHED.9. FOR DETAILED BOARD WISE BOM, REFER ANNEXURE-3B.10. FOR DETAILED MODULE WISE BOM, REFER ANNEXURE-3C.11.ADDITION/DELETION OF QUANTITIES SHALL BE APPLICABLE AT THE QUOTED PRICE.12. FOLLOWING INFORMATION SHALL ALSO BE FURNISHED ALONG WITH BID:a. COMPLETE DIMENSIONS OF ALL THE BOARDS INCLUDING NO OF ACB, MCC AND DUMMY PANELS.b. DIMENSIONS OF EACH TYPE OF PANEL.c. MODULE SIZE OF EACH TYPE OF FEEDER.d. MINIMUM CLEARANCES REQUIRED ON ALL SIDES FOR EACH TYPE OF PANEL.13. DOUBLE COMPRESSION, NICKLE PLATED BRASS CABLE GLANDS & HEAVY DUTY LUGS OF BHEL APPROVED MAKE FOR EXTERNAL POWER, CONTROL & EARTHING CONNECTIONS AT SUPPLIED EQUIPMENT END AND FOUNDATION BOLT ARE IN THE SCOPE OF BIDDER. BIDDER TO QUOTE ALL EQUIPMENT WITH CABLE GLANDS, LUGS ABD FOUNDATION BOLTS.

14. COMMISSIONING AND TRAINING CHARGES OF NUMERICAL RELAYS SHALL BE INCLUDED IN THE PRICE QUOTED FOR SWGR & NO EXTRA CHARGESWILL BE GIVEN FOR THE SAME.

PAGE 2 OF 4

123
Text Box
123
Text Box

1 X 500 MW UNCHAHAR FG TPP UNPRICED PRICE SCHEDULE OF BOARDWISE BILL OF MATERIAL FOR LV SWGR ANNEXURE-3B

TYPE OF FEEDER 6DA 6KA 6KB 6QA 6HA 6HB 6HC 6HD 6DB 0DA 0QA 0TA 6TA 6TB 0SB 0DC 0DD 0DE 6DG 6FA 0SA 0DB 0SC 6DC 6DD 6DD 6DD 0SD TOTAL QTY

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in INR

Total Supply and E&C in INR

DAET(I/C)(3200A) 2 3 2 2 2 2 2 2 17DAE(B/C)(3200A) 1 2 1 1 1 1 1 1 9DAET(I/C)(2500A) 2 2DAE(TIE)(2500A) 2 2 4DAE(B/C)(2500A) 1 1 2DAE(I/C)(2500A)DAEG(I/C)(2500A) 2 2DAET(I/C)(1600A) 2 2DAE(B/C)(1600A) 1 1DAET(I/C)(1000A) 2 2DAE(B/C)(1000A) 1 1DAE(I/C)(1000A) 2 2 2 2 8DAE(B/C)(1000A) 1 1 1 1 4DAE(O/G)(1000A) 4 5 4 13DAE(O/G)(1600A)DAE(O/G)(2500A) 3 3EM3(I/C)(630A) 2 2 2 2 2 10EM3(B/C)(630A) 1 1 1 1 1 5EM3(I/C)(630A) (fixed type) 2 2EM3(B/C)(630A) (fixed type) 1 1EM3(I/C)(400A) 2 2 4EM3(B/C)(400A) 1 1 2EMC3(I/C)(250A)EMC3(I/C)(250A) (fixed type) 2 2 4EMC3(B/C)(250A)EM3(I/C)(250A) 2 2EM3(B/C)(250A)CH(400A) (fixed type) 2 2DC(1000A) (fixed type) 2 2HD(1000A) (fixed type) 1 1DB(1000A) (fixed type) 2 2EM3(O/G) (630A) 7 2 2 4 2 2 2 2EM3(O/G) (400A) 3 3 10 3 2 5 22 24 22 22 116EM3(O/G) (250A) 3 4 4 4 2 17EM3(O/G) (250A) (fixed type) 8 8E3(O/G)(6A) 6 5 4 6 9 9 9 39 87E3(O/G)(10A) 8 12 4 4 4 4 36E3(O/G)(16A) 4 7 5 8 3 9 6 8 6 6 23 20 105E3(O/G)(20A) 4 8 3 3 4 6 4 6 5 43E3(O/G)(25A) 3 1 7 11E3 (O/G)(32A) 25 4 20 28 4 4 5 13 22 14 4 2 4 7 156E3 (O/G)(50A) 3 4 12 3 22E3 (O/G)(63A) 16 8 8 4 4 8 5 6 9 3 2 3 2 2 2 2 3 87E3 (O/G)(80A) 4 5 9E3 (O/G)(100A) 3 3 3 3 2 2 2 2 20E3 (O/G)(125A) 12 13 5 4 3 3 3 6 2 5 2 58E3 (O/G)(160A) 3 3 3 5 3 10 27E3 (O/G)(200A) 4 3 6 4 5 2 2 26E3(O/G)(6A) (fixed type) 194 23 217E3(O/G)(10A) (fixed type) 26 8 34E3(O/G)(16A) (fixed type) 26 4 4 34E3(O/G)(20A) (fixed type) 14 25 39E3(O/G)(25A) (fixed type) 42 42E3 (O/G)(32A) (fixed type) 55 44 5 104E3 (O/G)(50A) (fixed type) 10 10E3 (O/G)(63A) (fixed type) 7 32 39E3 (O/G)(80A) (fixed type) 11 11E3 (O/G)(100A) (fixed type) 3 3E3 (O/G)(125A) (fixed type) 30 4 34E1(6A) 22 3 6 17 8 16 72E1(10A) 10 4 3 3 20E1(16A) 6 5 7 6 2 2 13 41E1(20A) 3 10 3 12 28E1(25A)E1(32A) 9 22 5 9 45E1(63A)E1(100A)E1(6A) (fixed type) 13 13E1(10A) (fixed type) 15 15E1(25A) (fixed type) 12 12E1(63A) (fixed type) 4 4EA1(.5KW)EA1(2KW)EA1(3KW)EA1(5.5KW) 4 4EA3(.06KW)EA3(.09KW)EA3(.55KW)EA3(1.1KW)EA3(1.2KW)EA3(1.5KW)EA3(2KW)EA3(2.2KW)EA3(3KW)EA3(3.7KW)EA3(4KW)EA3(4.5KW)EA3(5KW) 4 4EA3(5.5KW)EA3(7KW)EA3(7.5KW)EA3(8KW)EA3(9KW) 4 4EA3(10KW)EA3(15KW)

1 X 500 MW UNCHAHAR FG TPP UNPRICED PRICE SCHEDULE OF BOARDWISE BILL OF MATERIAL FOR LV SWGR ANNEXURE-3B

TYPE OF FEEDER 6DA 6KA 6KB 6QA 6HA 6HB 6HC 6HD 6DB 0DA 0QA 0TA 6TA 6TB 0SB 0DC 0DD 0DE 6DG 6FA 0SA 0DB 0SC 6DC 6DD 6DD 6DD 0SD TOTAL QTY

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in INR

Total Supply and E&C in INR

EA3(16KW)EA3(18KW)EA3(22KW) 5 5EA3(27KW)EA3(30KW)EA3(40KW)DN1 (0-5.5KW) 3 3 6DK2 (0.0-5.5KW) 34 13 28 19 11 5 10 10 37 29 29 29 46 2 53 33 388DK2 (5.6-7.0KW) 18 18DK2 (7.1-13.0KW) 3 14 3 2 3 10 7 7 10 7 66DK2 (13.1-24.0KW) 2 2 2 4 4 5 5 10 15 3 4 56DK2 (24.1-29.9KW) 2 2DK21 (30.0-44.9KW) 2 3 11 3 2 3 3 27DK21 (45.0-55.0KW) 8 5 1 14DK21 (55.1-75.0KW) 2 3 3 2 10DK21 (75.1.1-89.9.0KW) 3 5 3 11DK21 (90-109.9.0KW) 2 5 7DK2E(0.0-5.5KW)DK2E(5.6-7.0KW)DK2E(7.1-13.0KW) 2 2DK2E(13.1-24.0KW)DK2E(24.1-29.9KW)DK21E (30.0-37.0KW)DK21E (37.1-55.0KW)DK21E (55.1-75.0KW)DK21E (75.1-89.9.0KW)DK21E (90-109.9.0KW) 4 4K2/K3 (0.0- 5.5KW) 10 14 3 3 15 4 10 59K2/K3 (5.6-7.0KW)K2/K3 (7.1-13.0KW) 5 6 5 5 21K2/K3 (13.1-24.0KW) 3 3 6K2/K3 (24.1-29.9KW)K21/K31(30.0-37.0KW) 8 8K21/K31(37.1-55.0KW)K21/K31(55.1-75.0KW)K21/K31(75.1-89.9KW)K21/K31(90-109.9KW)DM(110.0-200.0KW) 5 18 3 5 4 3 38CS 2 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 49VM 2 1 2 2 1 2 1 2 2 2 2 2 2 2 2 2 29G1 2 2 2 2 2 2 2 2 2 2 20G2 2 2SH 1 1 1 1 1 1 1 1 2 2 2 2 1 17X 6A 11 11X 10A 83 83X 16A 7 7X 25A 19 19X 32AX 50A 10 10X 63A 5 5X 80AX 100AX 125A 4 4X 160A 4 4X 200 AX 400 A 3 3DW UP TO 10AS 2 2TOTAL PRICE

SL. NO.

ITEM DESCRIPTION QUANTITY

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self

manufactured only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection & Commissioning Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices including Service Tax

in INR

Total Supply and E&C in

INR

1BREAKER LIFTING AND HANDLING TROLLEY (TELESCOPIC TROLLEY)

15

2 MODULE RACKING HANDLE FOR BREAKERS 12

3MODULE RACKING HANDLE FOR MCC MODULES

20

4

TEST PLUG WITH COUPLING CABLES FOR TESTING BREAKER IN WITHDRAWN POSITION

4

Annexure-3DTools & Tackles and Accessories

1 FACTORY BUILT ASSEMBLIES (PCC/MCC/DB)

1.1 Busbar supports (Horizontal) 1 set of 3 1SET1.2 Primary isolating contacts (Bus side)

of each rating

1 set of 3 1SET

1.3 Primary isolating contacts (Load side) of each rating

1 set of 3 1SET

1.4 Secondary isolating contacts of each rating

1 set of 3 1SET

1.5 Gaskets (each size) Meter 101.6 Fixed Terminal (1way) Nos. 201.7

Shrouds (for outgoing modules)

Nos. one for each physical size of

module

1.8 Wire (for secondary wiring)a. 2.5 mm2 Metres 100

b. 1.5mm2 Metres 100

1.9 Lugs (for secondary wiring) Nos. 100

2Air Circuit Breaker(for each rating)

2.1Shunt trip coil

Nos. 1

2.2spring charging motor

Nos. 1 motor of each rating

2.3closing coil

Nos. 1

2.4Auxiliary switch

Nos. 1

3ISOLATING SWITCH

3.1Main contact kit for each rating

1 set of 3 poles

1

4POWER CONTACTORS

4.1Contactor coil of each rating

Nos. 1

4.2Contacts kit (main) for each rating

1 set of 3 poles

1

5AUXILIARY CONTACTORS

5.1Complete unit with 2NO + 2NC contacts

Nos. 1 no. of each rating/type

5.2Contactor coils

a.AC for each rating

Set 1

b.DC for each rating

Set 1

6MCCB

ANNEXURE 3E1

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E &

C in INR

Total E & C prices including Service Tax

in INR

Total Supply and E&C in INR

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including Service tax @

Total FOR Site Price (Supply) in INR S.No. ITEM / COMPONENT UNIT QUANTITY

Total Ex-Works Price duly packed in INR/Total Price.

Unit Ex-works price/Unit Price

6.1MCCB (EACH RATING)

Nos. 1

7PUSH BUTTONS

6.1Actuator contacts

Nos. 5

6.2Element

Nos. 5

8INDICATING LAMPS

8.1Complete unit

Nos. 10

8.2Lens (assorted)

Nos. 10

9OTHERS

9.1Selector & control switch (each type)

Nos. 1

9.2AC Voltmeter (0-500V)

Nos. 1

9.3DC Voltmeter (0-300 or 0-150 V)

Nos. 1

10LT BUSDUCT

10.1Busduct support insulators

TPN set for each rating of busduct.

1

10.2Gaskets for each rating of busduct

set (consisting of 10 meters or 2 nos.each of

1

11 NGR11.1 Porcelein post/support

insulator (for mounting on structure)

Nos. 1

11.2 Resistor bank support insulator (mounted inside enclosure)

Nos. 1

11.3Porcelein terminal bushing

Nos. 1

Note:

Bidder to ensure correctness & completeness of type and quantity of every item considered by them in above list. Bidder to note that there will not be any commercial implication to NBPPL as per final requirement after award of contract / during detailed engineering based on BOQ of various equipments given in the specification.

ITEM DESCRIPTION QTYUnit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on

E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

1. Complete pole of breaker 1 No. of each type & rating. 2. Spring charging motors 1 No. of each type & rating 3.Aux. Contact set 5 Nos. of each rating. 4. Limit switches 5 Nos. of each rating 5. Arc chutes 3 Nos. of each rating 6. Fixed contact set 5 Sets. 7. Moving contact set 5 Sets. 8. Arcing contact 6 Sets. 9. Charging spring 2 Nos. of each type 10. Current transformer (metering) 3 Nos. 11. Current transformer (protection) 3 Nos. 12. Closing coil 5 Nos. 13. Trip coil 5 Nos. 14. CT for Bimetal O/L relays 3 Nos. of each rating 15. Voltage transformer 3 Nos. 16. Control supply transformer 1 No. 17. Ammeter 1 No. of each range 18. Voltmeter 1 No. of each range 19. Relays 1 No. of each type & rating 20. Power contactor 1 No. of each rating. 21. Coil of above contactor 1 No. of each rating. 22. Air break switches 1 No. of each rating. 23. DP air break switches (DC) 1 No. 24. Control & selector switches. 3 Nos. of each rating. 25. Control fuses & neutral links 1 No. of each rating. 26. Indicating lamps 2 Nos. of each type 27. Bus bar support insulators 1 No. of each size. 28. Bus duct flexibles connectors 1 No. of each type. 29. Primary disconnect in MCC (Male / female contact) 5 Nos. 30. Push buttons 2 Nos. of each type & colour. 31. Power fuses 5 Nos. for each rating. 32. Thermal bimetal relays 2 Nos. of each rating 33. Indication lamp holders complete. 2 Nos. of each rating 34. Maintenance tools accessories formaintenance 1 Set 35. Terminal blocks 1Set for each type/rating 36. Busbar aluminium flat pieces 3 Meter of each size 37. Busbar angles/formed pieces for breaker 1 No. of each type & size

MANDATORY SPARE FOR AC, VENTILATION, COMPRESS AIR SYSTEM ANNEXURE-3F

SL.NO. DETAILS QUANTITY Unit Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on

self manufactu

red only

VAT/CST @ … in

INR on self manufactu

red only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Charges INR

Service tax @ including cess on Total Charges in

INR

Total Charges including Service

Tax in INR

1 LUMP SUM ALL INCLUSIVE CHARGES PER VISIT FOR SKILLED TECHNICIAN (EXCEPT DAILY CHARGES)

5 VISITS

2 LUMP SUM ALL INCLUSIVE DAILY CHARGES FOR SKILLED TECHNICIAN

30 DAYS

3 LUMP SUM ALL INCLUSIVE CHARGES PER VISIT FOR SERVICE ENGINEER (EXCEPT DAILY CHARGES)

5 VISITS

4 LUMP SUM ALL INCLUSIVE DAILY CHARGES FOR SERVICE ENGINEER

15 DAYS

NOTES:

1) AMOUNT PAYABLE FOR SKILLED TECHNICIAN PER VISIT TO SITE = VISIT CHARGES AS PER SL. NO. 1 ABOVE + (DAILY CHARGES AS PER SL. NO. 2 ABOVE X NO. OF DAYS AT SITE) (TO BE CERTIFIED BY SITE)

2) AMOUNT PAYABLE FOR SERVICE ENGINEER PER VISIT TO SITE = VISIT CHARGES AS PER SL. NO. 3 ABOVE + (DAILY CHARGES AS PER SL. NO. 4 ABOVE X NO. OF DAYS AT SITE) (TO BE CERTIFIED BY SITE)

ANNEXURE 3GSite Visit Charges

 1X500 MW UCHAHAR FGTPS (UNIT‐6) ERECTION AND  COMMISIONING  BOM  FOR LV SWITCHGEAR   ANNEXURE‐3A

RATING(A) BOARD NO.

1 UNIT SERVICE SWBD. NOS. 1 3200 A 6DA

2 BOILER MCC NOS. 1 1000 A 6HA

3 TURBINE MCC NOS. 1 1000 A 6KA

4 BOILER V&D MCC NOS. 1 250 A 6HB

5 TURBINE VALVE MCC NOS. 1 250 A 6KB

6 UNIT SERVICE ACDB. NOS. 1 630 A 6QA

7 BOILER ACDB. NOS. 1 630 A 6HC

8 UNIT EMERGENCY SWBD NOS. 1 2500 A 6DG

9 ESP‐1 LT MAIN SWITCH BOARD NOS. 1 3200 A 6DC

10 ESP‐2 LT MAIN SWITCH BOARD NOS. 1 3200 A 6DD

11 ESP‐3 LT MAIN SWITCH BOARD NOS. 1 3200 A 6DE

12 ESP‐4 LT MAIN SWITCH BOARD NOS. 1 3200 A 6DF

13 ESP A/C & VENT MCC NOS. 1 400 A 6TB

14 ESP AREA MCC NOS. 1 250 A 6HD

15 COOLING TOWER SWBD NOS. 1 3200 A 6DB

16 STATION SERVICE SWBD. NOS. 1 3200 A 0DA

17 MISC. SERVICE MCC NOS. 1 630 A 0QA

18 VENTILATION MCC NOS. 1 1000 A 6TA

19 AIR CONDITIONING MCC NOS. 1 1000 A 0TA

20 FIRE WATER/WTP SWBD. NOS. 1 3200 A 0DD

21 CHLORINATION PLANT MCC NOS. 1 400 A 0SA

22 HYDROGEN & PT PLANT MCC NOS. 1 630 A 0SB

23 RO DM PLANT  MCC NOS. 1 400 A 0SC

24 FUEL OIL SWBD NOS. 1 1600 A 0DB

25 MAKE UP WATER SWGR NOS. 1 1000 A 0DE

26 SERVICE BUILDING SWGR NOS. 1 2500 A 0DC

27 CPU/COMPRESSOR MCC NOS. 1 630 A 0SD

28 220V MAIN DCDB NOS. 1 1000A 6FA

29 240V AC FUSE DBS NOS. 12 63A 12WAY 1P O/G (16 amp)

30 220V FUSE DCDB NOS. 4 50A  12 WAY O/G (10 amp)

31 LT BUSDUCT‐3200A SET    4

LT BUSDUCT 3200A, FROM LV 

TERMINALS OF DRY TYPE 

TRANSFORMERS TO PCC / PMCC. 

EACH SET OF 15 M

32 LT BUSDUCT‐3200A SET    13

LT BUSDUCT 3200A, FROM LV 

TERMINALS OF OIL FILLED  

TRANSFORMERS TO PCC / PMCC. 

EACH SET OF 4 M 

33 LT BUSDUCT‐2500A SET    2

LT BUSDUCT 2500A, FROM LV 

TERMINALS OF OIL FILLED  

TRANSFORMERS TO PMCC. EACH 

SET OF 15 M

34 LT BUSDUCT‐1600A SET    2

LT BUSDUCT 1600A, FROM LV 

TERMINALS OF OIL FILLED TYPE 

TRANSFORMERS TO PMCC. EACH 

SET OF 15 M

Sr.No. ITEM NAME

Total Supply

and E&C in INR

Excise Duty @ on

self manufactu

red only

VAT/CST @ … in

INR on self manufactu

red only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR UOM TOTAL QTY.

Total Erection & Commissi

oning Charges in INR

Service tax @

including cess on E & C in INR

Total E & C prices including Service

Tax in INR

REMARKSUnit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

PAGE 1 OF 4

123
Text Box
123
Text Box

 1X500 MW UCHAHAR FGTPS (UNIT‐6) ERECTION AND  COMMISIONING  BOM  FOR LV SWITCHGEAR   ANNEXURE‐3A

35

EACH SET COMPRISING OF:

FOR DRY TYPE TRANSFORMERS 1)   90 DEG BEND – 2NOS              

2)   FLEXIBLE (CU) AT 

TRANSFORMER END – 1SET         

3)   ADAPTER – 1NO.                      

4)   PHASE CROSSOVER – 1 NO.   

5)   SET OF HARDWARE AT 

TRANSFORMER & SWITCHGEAR 

END     

6)    EXPANSION JOINT – 1NO.

7)    WALL FRAME ASSEMBLY – 

N/A

8)   SUPPORT STRUCTURE – N/A

FOR OIL FILLED TYPE TRANSFORMERS                 1)   90 DEG BEND – 4 NOS 

2)   FLEXIBLE (CU) AT 

TRANSFORMER END – 

1SET             

3)   ADAPTER – 1NO.           

4)   PHASE CROSSOVER – 

1NO.                                      

5)   SET OF HARDWARE 

AT TRANSFORMER & 

SWITCHGEAR END     

6)    EXPANSION JOINT – 

1NO.

7)    WALL FRAME 

ASSEMBLY – 1 No.

8)   SUPPORT STRUCTURE 

– 200KG

36LOCAL PUSH BUTTON 

STATIONS TYPE ‐ ANOS. 700

EMERGENCY STOP PUSH 

BUTTON STATION.  1NO. PRESS 

TO LOCK & TURN TO RELEASE 

TYPE EMERGENCY STOP PB WITH 

2NO + 2NC CONTACTS WITH 

SUPPORTING STRUCTURE

37LOCAL PUSH BUTTON 

STATIONS TYPE ‐ BNOS. 25

START & EMERGENCY STOP 

PUSH BUTTON STATION .1 NO. 

START PB & 1NO MUSHROOM 

HEAD STAYPUT WITH  

EMERGENCY STOP PB WITH 2NO 

+ 2NC CONTACTS WITH 

SUPPORTING STRUCTURE

38LOCAL PUSH BUTTON 

STATIONS TYPE ‐ CNOS. 25

 FLAME PROOF EMERGENCY 

STOP PUSH BUTTON STATION.  

1NO. PRESS TO LOCK TURN TO 

RELEASE TYPE EMERGENCY STOP 

PB WITH 2NO + 2NC CONTACTS 

WITH SUPPORTING STRUCTURE

39 LOCAL MOTOR STARTERS 0.37  NOS. 5

40 LOCAL MOTOR STARTERS 0.55  NOS. 10

41 LOCAL MOTOR STARTERS 0.75  NOS. 10

42 LOCAL MOTOR STARTERS 1.10  NOS. 25

43 LOCAL MOTOR STARTERS 1.50  NOS. 25

44 LOCAL MOTOR STARTERS 2.20  NOS. 10

45 LOCAL MOTOR STARTERS 3.70  NOS. 5

46 LOCAL MOTOR STARTERS 5.5  NOS. 5

47NGR 11KV (300A, 10 SEC, 

22.163 OHMS)NOS. 3

ALL NECESSARY SUPPORTING 

STRUCTURES ARE PART OF NGR

48NGR 3.3KV (300A, 10 SEC, 6.74 

OHMS)NOS. 8

PAGE 2 OF 4

123
Text Box
123
Text Box

GROUP-A None

GROUP-B 1 Complete breaker 3 Nos. of each type & rating 2 Ammeter 2 Nos. of each type, size &

range 3 Voltmeter 2 Nos. of each type, size &

range 4 Relays 2 Nos. of each type 5 Bus bar support insulators(Porcelain) 10 Nos.

GROUP-C 1 Spring charging motors 3 Nos. of each type & rating 2 Aux. Contact set 6 Sets of each type & rating 3 Limit switches 10 Nos. 4 Arc chutes 4 Nos. of each type & rating 5 Fixed contact set 6 Sets of each type & rating 6 Moving contact set 6 Sets of each type & rating 7 Arcing contact 6 Sets of each type 8 Charging spring 4 Nos. of each type & rating 9 Current transformer 3 Nos. of each type & ratio

10 Closing coil 12 Nos. of each type & rating 11 Trip coil 12 Nos. of each type & rating 12 CT for Bimetal O/L relays 3 Nos. of each type & rating 13 Voltage transformer 3 Nos. of each type & ratio 14 Control supply transformer 3 Nos.of each type and rating 15 (a) Power contactor 2 Nos. of each type & rating

(b) Coil of above contactor 2 Nos. of each type & rating 16 Air break switches 3 Nos. of each type & rating 17 DP air break switches(DC) 3 Nos. of each type & rating 18 Control & selector switches 5 Nos. of each type & rating

19 Control fuses & neutral links Total 50 Nos.( Fuses) & 10 Nos. (Neutral links), to cover all the ratings.

20 Indicating lamps Total 50 Nos. to cover all the types & ratings

Total E & C prices including Service Tax

in INR

Total Supply and E&C in INR

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured

onlySl No. Item Description Quantity

LIST OF MANDATORY SPARES FOR 500MW UNITS LT SWITCHGEAR AND LT BUSDUCTANNEXURE-3E2

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E &

C in INR

21 Vertical bus bar dropper support insulators(FRP) 25 Nos. 22 Bus duct flexible connectors 1 Set for thee phases of each type & size

23(a) Primary disconnect in MCC( Bus bar end)(Male/female contact) Total 15 Nos. proportionately divide for all ratings

(b) Secondary disconnect in MCC(Cable end) Total 15 Nos. proportionately divide for all ratings 24 Push buttons 15 Nos.

25 Power fuses Total 100 Nos. proportionately divide for all ratings

26 Thermal Bimetal relays Total 30 Nos. proportionately divide for all ratings 27 Current transducers 12 Nos. proportionately divide for all ratings 28 Voltage transducers 12 Nos. proportionately divide for all ratings. 29 Indication lamp holders complete 10% of each type & rating 30 Busbar aluminium flat pieces 12 meters of each type & rating 31 Busbar angles/formed pieces for breaker 2 Nos. of each type 32 Terminal blocks 12 Nos. of each type & rating

CHARGES OF NETWORKING HARDWAREFOR NUMERICAL RELAYS MULTIFUNCTION METERS

ANNEXURE-3M

1.0 NETWORKING OF NUMERICAL RELAYS:-

Sl. No. ITEM DESCRIPTION QUANTITY

Unit Ex-works price/Unit

Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufacture

d only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including cess on E &

C in INR

Total E & C prices

including Service Tax

in INR

Total Supply and E&C in INR

1ETHERNET SWITCHES ON IEC61850 (16 CHANNELS) 20 Nos.

3 DATA CABLE (CAT-5) FOR CONNECTION OF NUMERICAL RELAYS TO ETHERNET SWITCH

3 km

4

LAPTOP PC WITH LICENCED VERSION SOFTWARE, HARDWARE ALONGWITH CONNECTING CABLES FOR RELAY PARAMETERISATION

1 NO

NOTE

1)

2)

2ETHERNET SWITCHES ON IEC61850 (8 CHANNELS) 10 Nos.

All above items shall be supplied along with acessories (including special tools for installation) required for the completeness of system.

Looping of all the LT SWGR realys shall be in bidders scope.Bidder to configure each LT protection relay to provide protection & control facility up to data concentrator as per attched typical architecture for networking of numerical relays.(ANNEXURE-3P)

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

4. CABLING, EARTHING AND LIGHTNING PROTECTION

1x 500MW FGUTPP STAGE IV

PRICE SCHEDULE FOR CABLING, EARTHING LIGHTNING PROTECTION SYSTEMS (SUPPLY)

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in INR

Total Supply and E&C in INR

1.0 HOT DIP GALVANISED LADDER TYPE CABLE TRAY COMPLETE WITH COUPLER PLATES, FASTENERS, CLAMPS AND FIXING HARDWARES ETC.

i) CABLE TRAY 2 MM THICK- LADDER TYPE 150W MTR 4800 3400

ii) CABLE TRAY 2 MM THICK- LADDER TYPE 300W MTR 13000 9000

iii) CABLE TRAY 2 MM THICK- LADDER TYPE 600W MTR 26000 18200

2.0

HOT DIP GALVANISED PERFORATED TYPE CABLE TRAY COMPLETE WITH COUPLER PLATES, FASTENERS, CLAMPS AND FIXING HARDWARES ETC.

i) CABLE TRAY 2 MM THICK- PERFORATED TYPE 150W MTR 2000 1400

ii) CABLE TRAY 2 MM THICK- PERFORATED TYPE 300W MTR 5200 3700

iii) CABLE TRAY 2 MM THICK- PERFORATED TYPE 600W MTR 7700 5400

3.0 HOT DIP GALVANISED CABLE TRAY ACCESSORIES

3.1 LADDER TYPE HORIZONTAL 90 DEG. BEND-600mm RADIUS

i) LAD HOR 90DEG BEND 2 MM THICK 600 RAD 150W NOS 20 15

ii) LAD HOR 90DEG BEND 2 MM THICK 600 RAD 300W NOS 20 15

iii) LAD HOR 90DEG BEND 2 MM THICK 600 RAD 600W NOS 250 175

3.2LADDER TYPE VERTICAL 90 DEG. BEND-600mm RADIUS (INSIDE)

i) LAD VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 150W NOS 10 7

ii) LAD VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 300W NOS 10 7

iii) LAD VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 600W NOS 50 35

3.3LADDER TYPE VERTICAL 90 DEG. BEND-600mm RADIUS (OUTSIDE)

i) LAD VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 150W NOS 10 7

ii) LAD VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 300W NOS 10 7

iii) LAD VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 600W NOS 50 35

3.4 LADDER TYPE TEES-600mm RADIUS

i) LAD TEES 600MM RADIUS 2 MM THICK 150W NOS 10 7

ii) LAD TEES 600MM RADIUS 2 MM THICK 300W NOS 140 100

iii) LAD TEES 600MM RADIUS 2 MM THICK 600W NOS 320 230

3.5 LADDER TYPE CROSS-600mm RADIUS

i) LAD CROSS 600 RAD 2 MM THICK 300W NOS 10 7

ii) LAD CROSS 600 RAD 2 MM THICK 600W NOS 25 20

3.6 LADDER TYPE REDUCERS

i) LAD REDUCER (50% LHS/RHS) 2 MM THICK 600-300W NOS 10 8

ii) LAD REDUCER (50% LHS/RHS) 2 MM THICK 600-150W NOS 10 8

iii) LAD REDUCER (50% LHS/RHS) 2 MM THICK 300-150W NOS 10 8

3.7 PERFORATED TYPE HORIZONTAL 90 DEG. BEND-600mm RADIUS

i) PER HOR 90DEG BEND 2 MM THICK 600 RAD 150W NOS 10 7

ii) PER HOR 90DEG BEND 2 MM THICK 600 RAD 300W NOS 10 7

iii) PER HOR 90DEG BEND 2 MM THICK 600 RAD 600W NOS 100 70

3.8PERFORATED TYPE VERTICAL 90 DEG. BEND-600mm RADIUS (INSIDE)

i) PER VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 150W NOS 10 7

ii) PER VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 300W NOS 10 7

iii) PER VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 600W NOS 50 35

3.9PERFORATED TYPE VERTICAL 90 DEG. BEND-600mm RADIUS (OUTSIDE)

i) PER VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 150W NOS 10 7

ii) PER VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 300W NOS 10 7

iii) PER VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 600W NOS 50 35

3.10 PERFORATED TYPE TEES-600mm RADIUS

i) PER TEES 600MM RADIUS 2 MM THICK 150W NOS 10 7

ii) PER TEES 600MM RADIUS 2 MM THICK 300W NOS 10 7

iii) PER TEES 600MM RADIUS 2 MM THICK 600W NOS 10 7

3.11 PERFORATED TYPE CROSS-600mm RADIUS

i) PER CROSS 600 RAD 2 MM THICK 300W NOS 10 7

ii) PER CROSS 600 RAD 2 MM THICK 600W NOS 20 10

3.12 PERFORATED TYPE REDUCERS

i) PER REDUCER (50% LHS/RHS) 2 MM THICK 600-300W NOS 10 8

ii) PER REDUCER (50% LHS/RHS) 2 MM THICK 600-150W NOS 10 8

iii) PER REDUCER (50% LHS/RHS) 2 MM THICK 300-150W NOS 10 8

ANNEXURE-4A: MAIN ITEMS

Item.No Item UnitOrder

QuantityLot-I

Quantity

PRICES

1x 500MW FGUTPP STAGE IV

PRICE SCHEDULE FOR CABLING, EARTHING LIGHTNING PROTECTION SYSTEMS (SUPPLY)

3.13 TROUGHS

i) 50 MM WIDE MTR 1000 700

ii) 75 MM WIDE MTR 1000 700

3.14

HOT DIP GALVANISED CABLE TRAY COVER COMPLETE WITH FORMED CHANNEL, PIPE, GI FLAT, BOLTS WITH NUTS & WASHERS & FIXING HARDWARES ETC. (1.6mm)THICK GALVANISED MS SHEET)

i) COVER 1.6MM THK- NON PERFORATED GALV MS 150W MTR 100 5

ii) COVER 1.6MM THK- NON PERFORATED GALV MS 300W MTR 100 5

iii) COVER 1.6MM THK- NON PERFORATED GALV MS 600W MTR 100 5

4.1SINGLE CHANNEL SC1 (IN STANDARD LENGTH OF 6M PER PIECE) MTR 10000 7000

4.2DOUBLE CHANNEL DC1 (IN STANDARD LENGTH OF 6M PER PIECE) MTR 16000 11200

4.3

CANTILEVER ARM EACH COMPLETE WITH 2 NOS. - M12 HEX. BOLT & WASHER 2 NOS. - M12 SPRING NUTS 2 NOS. - M6 PAN HEAD SCREWS & WASHER 2 NOS. - M6 SPRING NUTS

i) Cantilever arm of 750 mm for600mm wide cable trays Nos. 1000 700

ii) Cantilever arm of 620 mm for 600mm wide cable trays Nos. 19000 13300

iii) Cantilever arm of 320 mm for 300mm wide cable trays Nos. 9500 6650

iv) Cantilever arm of 170 mm for 150mm wide cable trays Nos. 3500 2450

4.4CLAMPS AND FITTINGS COMPLETE WITH REQUIRED HARDWARES (Spring nuts/ washers etc. as required for complete installation)

i) 90˚ ANGLE FITTING HL1 Nos. 6000 4200

ii) CLAMP FOR SINGLE CHANNEL CC1 Nos. 14500 10150

iii) CLAMP FOR DOUBLE CHANNEL CC2 Nos. 7200 5040

(iv) BASE PLATE FOR SINGLE CHANNEL BP1 Nos. 300 210

(v) BASE PLATE FOR DOUBLE CHANNEL BP2 Nos. 1800 1260

(vi) BEAM CLAMP BC1 Nos. 400 280

(vii) TRAY FIXING CLAMP TC1 Nos. 2700 1890

(viii) FLAT PLATE STRAIGHT FITTING PF2 Nos. 200 140

(ix) FLAT PLATE TEE FITTING PF1 Nos. 200 140

(x) 90˚ ANGLE FITTING LA1 Nos. 9100 6370

(xi) TRESTLE BRACKET Nos. 200 140

5.0 DOUBLE COMPRESSION HEAVY DUTY BRASS CABLE GLANDS

ABOVE (MM) UP TO (MM)

(i) -- 15 Nos. 600 420

(ii) 15 18 Nos. 160 110

(iii) 18 21 Nos. 100 70

(iv) 21 24 Nos. 110 80

(v) 24 27 Nos. 20 15

(vi) 27 30 Nos. 100 70

(vii) 30 33 Nos. 30 20

(viii) 33 36 Nos. 70 50

(ix) 36 39 Nos. 20 15

(x) 39 42 Nos. 50 35

(xi) 42 46 Nos. 15 10

(xii) 46 50 Nos. 30 20

(xiii) 50 54 Nos. 30 20

(xiv) 54 58 Nos. 30 20

(xv) 58 62 Nos. 20 14

(xvi) 62 67 Nos. 10 5

(xvii) 67 74 Nos. 10 5

6.0 TINNED COPPER LUGS

(SOLDERLESS CRIMPING TYPE) (i) 2.5 SQ MM Nos. 1100 770

(ii) 6 SQ MM Nos. 85 60

(iii) 10 SQ MM Nos. 260 180

(iv) 16 SQ MM Nos. 40 30

(v) 25 SQ MM Nos. 340 240

(vi) 35 SQ MM Nos. 10 7

(vii) 50 SQ MM Nos. 300 210

(viii) 95 SQ MM Nos. 130 90

(ix) 120 sq mm Nos. 20 15

(x) 150 SQ MM Nos. 30 20

(xi) 240 SQ MM Nos. 95 70

(xii) 400 SQ MM Nos. 50 35

(xiii) 630 SQ MM Nos. 40 30

7.0 TINNED COPPER LUGS

(WITH INSULATING SLEEVE)

(i) 1.5 SQ MM Nos. 950 650

(ii) 2.5 SQ MM Nos. 290 200

8.0 ALUMINIUM LUGS

(i) 10 SQ MM Nos. 50 35

(ii) 16 SQ MM Nos. 50 35

(iii) 25 SQ MM Nos. 50 35

(iv) 35 SQ MM Nos. 50 35

(v) 50 SQ MM Nos. 50 35

(vi) 95 SQ MM Nos. 50 35

(vii) 120 sq mm Nos. 50 35

(viii) 150 SQ MM Nos. 50 35

(ix) 240 SQ MM Nos. 50 35

(x) 400 SQ MM Nos. 50 35

(xi) 630 SQ MM Nos. 50 35

1x 500MW FGUTPP STAGE IV

PRICE SCHEDULE FOR CABLING, EARTHING LIGHTNING PROTECTION SYSTEMS (SUPPLY)

9.0 TREFOIL CLAMPS ( FOR SIZES AS UNDER)

(i) TREFOIL CLAMP CABLE OD- 25.1 - 30MM NOS. 500 450

(ii) TREFOIL CLAMP CABLE OD- 30.1 - 35MM NOS. 3600 3240

(iii) TREFOIL CLAMP CABLE OD- 35.1 - 40MM NOS. 4950 4460

(iv) TREFOIL CLAMP CABLE OD-45.1 - 50MM NOS. 850 770

(v) TREFOIL CLAMP CABLE OD-50.1 - 55MM NOS. 500 450

10.0 HT TERMINATION KITS FOR

10.1 11 KV UNARMOURED HT. XLPE POWER CABLE

(i) 1C-630 sq mm Nos. 25 18

(ii) 1C-300 sq mm Nos. 75 54

(iii) 3C-150 sq mm Nos. 40 28

10.2 3.3 KV UNARMOURED HT.XLPE POWER CABLE

(i) 1C-630 sq mm Nos. 190 136

(ii) 1C-185 sq mm Nos. 65 46

(iii) 3C-150 sq mm Nos. 200 144

10.3 3.3 KV ARMOURED HT.XLPE POWER CABLE

(i) 3C-150 sq mm Nos. 6 4

11.0 HT/LT JOINT KITS FOR

11.1 11 KV UNARMOURED HT. XLPE POWER CABLE

(i) 1C-300 sq mm Nos. 34 24

11.2 3.3 KV UNARMOURED HT.XLPE POWER CABLE

(i) 3C-150 sq mm Nos. 50 34

11.3 1.1 KV UNARMOURED LT.XLPE POWER CABLE

(i) 3C-240 sq mm Nos. 2 1

(ii) 3C-150 sq mm Nos. 3 2

12.0 RIGID GALVANISED MS CONDUITS / PIPES

(i) 100 mm diameter Metres 1000 700

(ii) 75 mm diameter Metres 1000 700

(iii) 50 mm diameter Metres 2000 1400

(iv) 25 mm diameter Metres 1000 700

(v) 20 mm diameter Metres 1000 700

13.0FLEXIBLE CONDUITS MADE OF COLD ROLLED ANNEALED

ELECTRO GALVANISED MS STRIP (i) 25 mm diameter Metres 2000 1400

(ii) 18 mm diameter Metres 1000 700

14.0 PVC Conduits (i) 250 mm diameter Metres 100 70(ii) 200 mm diameter Metres 100 70(iii) 100 mm diameter Metres 100 70(iv) 50 mm diameter Metres 100 70

15.0LIGHTNING PROTECTION AND ABOVE GROUND

EARTHING MATERIAL

15.1 Hot Dip Galvanised Steel Flats (to be supplied in length of minimum 6 meters)

(i) 65X8 mm MT 84 60

(ii) 50X6 mm MT 2 1

(iii) 25X6 mm MT 14 10

15.2 20 mm dia., 1-meter long Hot Dip Galvanized GS rod for vertical air termination as per enclosed drawing no.PE-DG-999-509-E003 .sheet

03 of 04 Nos.100 70

15.3 Test link with 150x25x6 thick Hot Dip Galvanised GS Flat wih box as per enclosed drawing no. PE-DG-999-509-E003 sheet 01 of 04

Nos.185 130

15.4 8 SWG Hot Dip Galvanized GI Stranded WireMeters

5000 3500

15.5

Flexible braided Copper Conductor of 600 mm length (Cross section equivalent to 300 sq. mm) with tinned copper clamp connected by U-bolt for fence gate earthing as per enclosed drawing no. PE-DG-999-

509-E003 sheet 03 of 04 Nos.25 20

15.6 50NB Galvanized MS pipe 2 meter long Perforated along the length as per enclosed drawing no. PE-DG-999-509-E003 sheet 03 of 04

Nos.145 100

16.0 JUNCTION BOX (i) 6 WAY Nos. 10 7(ii) 12 WAY Nos. 25 17(iii) 24 WAY Nos. 20 14(iv) 36 WAY Nos. 10 7(v) 48 WAY Nos. 10 7

1x 500 MW FGUTPP STAGE IV

BILL OF MATERIAL FOR CABLING, EARTHING AND LIGHTNING PROTECTION SYSTEMS (INSTALLATION)

Unit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on

self manufactu

red only

VAT/CST @ … in

INR on self manufactu

red only

Freight including

Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissi

oning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices including Service

Tax in INR

1.0 HOT DIP GALVANISED LADDER TYPE CABLE TRAY COMPLETE WITH COUPLER PLATES, FASTENERS, CLAMPS AND FIXING HARDWARES ETC.

i) CABLE TRAY 2 MM THICK- LADDER TYPE 150W MTR 4800 3400

ii) CABLE TRAY 2 MM THICK- LADDER TYPE 300W MTR 13000 9000

iii) CABLE TRAY 2 MM THICK- LADDER TYPE 600W MTR 26000 18200

2.0

HOT DIP GALVANISED PERFORATED TYPE CABLE TRAY COMPLETE WITH COUPLER PLATES, FASTENERS, CLAMPS AND FIXING HARDWARES ETC.

i) CABLE TRAY 2 MM THICK- PERFORATED TYPE 150W MTR 2000 1400

ii) CABLE TRAY 2 MM THICK- PERFORATED TYPE 300W MTR 5200 3700

iii) CABLE TRAY 2 MM THICK- PERFORATED TYPE 600W MTR 7700 5400

3.0HOT DIP GALVANISED CABLE TRAY ACCESSORIES

3.1 LADDER TYPE HORIZONTAL 90 DEG. BEND-600mm RADIUS

i) LAD HOR 90DEG BEND 2 MM THICK 600 RAD 150W NOS 20 15

ii) LAD HOR 90DEG BEND 2 MM THICK 600 RAD 300W NOS 20 15

iii) LAD HOR 90DEG BEND 2 MM THICK 600 RAD 600W NOS 250 175

3.2LADDER TYPE VERTICAL 90 DEG. BEND-600mm RADIUS (INSIDE)

i) LAD VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 150W NOS 10 7

ii) LAD VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 300W NOS 10 7

iii) LAD VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 600W NOS 50 35

3.3LADDER TYPE VERTICAL 90 DEG. BEND-600mm RADIUS (OUTSIDE)

i) LAD VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 150W NOS 10 7

ii) LAD VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 300W NOS 10 7

iii) LAD VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 600W NOS 50 35

3.4 LADDER TYPE TEES-600mm RADIUS

i) LAD TEES 600MM RADIUS 2 MM THICK 150W NOS 10 7

ii) LAD TEES 600MM RADIUS 2 MM THICK 300W NOS 140 100

iii) LAD TEES 600MM RADIUS 2 MM THICK 600W NOS 320 230

3.5 LADDER TYPE CROSS-600mm RADIUS

i) LAD CROSS 600 RAD 2 MM THICK 300W NOS 10 7

ii) LAD CROSS 600 RAD 2 MM THICK 600W NOS 25 20

3.6 LADDER TYPE REDUCERS

i) LAD REDUCER (50% LHS/RHS) 2 MM THICK 600-300W NOS 10 8

ii) LAD REDUCER (50% LHS/RHS) 2 MM THICK 600-150W NOS 10 8

iii) LAD REDUCER (50% LHS/RHS) 2 MM THICK 300-150W NOS 10 8

3.7PERFORATED TYPE HORIZONTAL 90 DEG. BEND-600mm RADIUS

i) PER HOR 90DEG BEND 2 MM THICK 600 RAD 150W NOS 10 7

ii) PER HOR 90DEG BEND 2 MM THICK 600 RAD 300W NOS 10 7

iii) PER HOR 90DEG BEND 2 MM THICK 600 RAD 600W NOS 100 70

3.8PERFORATED TYPE VERTICAL 90 DEG. BEND-600mm RADIUS (INSIDE)

i) PER VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 150W NOS 10 7

ii) PER VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 300W NOS 10 7

iii) PER VER 90DEG BEND 2 MM THICK 600 RAD-INSIDE 600W NOS 50 35

3.9PERFORATED TYPE VERTICAL 90 DEG. BEND-600mm RADIUS (OUTSIDE)

i) PER VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 150W NOS 10 7

ii) PER VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 300W NOS 10 7

iii) PER VER 90DEG BEND 2 MM THICK 600 RAD-OUTSIDE 600W NOS 50 35

3.10 PERFORATED TYPE TEES-600mm RADIUS

i) PER TEES 600MM RADIUS 2 MM THICK 150W NOS 10 7

ii) PER TEES 600MM RADIUS 2 MM THICK 300W NOS 10 7

iii) PER TEES 600MM RADIUS 2 MM THICK 600W NOS 10 7

3.11 PERFORATED TYPE CROSS-600mm RADIUS

i) PER CROSS 600 RAD 2 MM THICK 300W NOS 10 7

ii) PER CROSS 600 RAD 2 MM THICK 600W NOS 20 10

3.12 PERFORATED TYPE REDUCERS

i) PER REDUCER (50% LHS/RHS) 2 MM THICK 600-300W NOS 10 8

ii) PER REDUCER (50% LHS/RHS) 2 MM THICK 600-150W NOS 10 8

ANNEXURE 4A: MAIN ITEMS

PRICES

Item.No Item Unit Order Quantity Lot-I Quantity

1x 500 MW FGUTPP STAGE IV

BILL OF MATERIAL FOR CABLING, EARTHING AND LIGHTNING PROTECTION SYSTEMS (INSTALLATION)

iii) PER REDUCER (50% LHS/RHS) 2 MM THICK 300-150W NOS 10 8

3.13 TROUGHS

i) 50 MM WIDE MTR 1000 700

ii) 75 MM WIDE MTR 1000 700

3.14

HOT DIP GALVANISED CABLE TRAY COVER COMPLETE WITH FORMED CHANNEL, PIPE, GI FLAT, BOLTS WITH NUTS & WASHERS & FIXING HARDWARES ETC. (1.6mm)THICK GALVANISED MS SHEET)

i) COVER 1.6MM THK- NON PERFORATED GALV MS 150W MTR 100 5

ii) COVER 1.6MM THK- NON PERFORATED GALV MS 300W MTR 100 5

iii) COVER 1.6MM THK- NON PERFORATED GALV MS 600W MTR 100 5

4.1SINGLE CHANNEL SC1 (IN STANDARD LENGTH OF 6M PER PIECE) MTR 10000 7000

4.2DOUBLE CHANNEL DC1 (IN STANDARD LENGTH OF 6M PER PIECE) MTR 16000 11200

5.0 CABLE LAYING

5.1 11/11 Kv UNARMOURED CABLES

i) 3C – 150 Sq. mm MTR 4500 3500

ii) 1C – 300 Sq. mm MTR 13000 10000

iii) 1C – 630 Sq. mm MTR 3000 2000

5.2 3.3/3.3 kV UNARMOURED CABLES

i) 3C –150 Sq. mm MTR 33000 23000

ii) 1C –185 Sq. mm MTR 3000 2500

iii) 1C –630 Sq. mm MTR 5000 4000

5.3 3.3/3.3 kV ARMOURED CABLES

i) 3C –150 Sq. mm MTR 500 500

5.4 1.1 KV UNARMOURED ALUMINIUM PVC FRLS POWER CABLES

i) 2C‐10 Sq. mm MTR 7000 5000

ii) 2C‐25 Sq. mm MTR 10000 7000

iii) 2C‐95 Sq. mm MTR 8000 6000

(iv) 3C‐10 Sq. mm MTR 19000 14000

(v) 3C‐25 Sq. mm MTR 18000 13000

(vi) 3C‐50 Sq. mm MTR 14000 10000

(vii) 3C‐95 Sq. mm MTR 8000 6000

(viii) 3.5C‐25 Sq. mm MTR 7000 5000

(ix) 3.5C‐50 Sq. mm MTR 29000 20500

(x) 3.5C‐95 Sq. mm MTR 4000 3000

(xi) 4C‐10 Sq. mm MTR 2000 1000

(xii) 1C‐35 Sq. mm MTR 3000 2000

(xiii) 1C‐120 Sq. mm MTR 8000 6000

5.5 1.1 KV UNARMOURED ALUMINIUM XPLE FRLS POWER CABLES

i) 01C X 400 Sq. mm MTR 21500 15000

ii) 01C X 630 Sq. mm MTR 16500 12000

iii) 03C X 150 Sq. mm MTR 4500 3500

(iv) 03C X 240 Sq. mm MTR 15000 11000

(v) 3.5C X 185 Sq. mm MTR 4000 3000

5.6 1.1 KV ARMOURED ALUMINIUM PVC FRLS POWER CABLES

i) 3.5C‐25 Sq. mm MTR 4000 3000

ii) 3.5C‐50 Sq. mm MTR 2500 2000

5.7 1.1 KV ARMOURED COPPER PVC FRLS POWER CABLES

i) 3C‐2.5 Sq. mm MTR 20000 14000

5.8 1.1 KV UNARMOURED COPPER PVC FRLS POWER CABLES

i) 2C‐2.5 Sq. mm MTR 16000 11000

ii) 3C‐2.5 Sq. mm MTR 137000 96000

iii) 2C‐6 Sq. mm MTR 19000 14000

5.9 1.1 KV UNARMOURED COPPER PVC FRLS CONTROL CABLES

i) 3C X 1.5 Sq. mm MTR 48000 34000

ii) 5C X 1.5 Sq. mm MTR 3000 2000

iii) 5C X 2.5 Sq. mm MTR 21000 15000

(iv) 7C X 1.5 Sq. mm MTR 25000 18000

(v) 12C X 1.5 Sq. mm MTR 3000 2000

(vi) 12C X 2.5 Sq. mm MTR 4000 3000

(vii) 19C X 1.5 Sq. mm MTR 1000 1000

5.10225 V INDIVIDUAL & OVERALL SCREENED UNARMOURED SCREENED CONTROL CABLE

i) 4P, 0.5 MTR 103000 72000

ii) 8P, 0.5 MTR 31000 22000

(iii) 12P,0.5 MTR 12500 9000

(iv) 24P, 0.5 MTR 10000 7000

5.11225 V OVERALL SCREENED UNARMOURED SCREENED CONTROL CABLE

i) 4P,0.5 MTR 206000 144000

ii) 8P, 0.5 MTR 30000 21000

(iii) 12P,0.5 MTR 31000 21000

1x 500 MW FGUTPP STAGE IV

BILL OF MATERIAL FOR CABLING, EARTHING AND LIGHTNING PROTECTION SYSTEMS (INSTALLATION)

6.0 HT POWER CABLE TERMINATION FOR

6.1 11 KV UNARMOURED HT. XLPE POWER CABLE

i) 1C-630 sq mm Nos. 25 18

ii) 1C-300 sq mm Nos. 75 54

iii) 3C-150 sq mm Nos. 40 28

6.2 3.3 KV UNARMOURED HT.XLPE POWER CABLE

i) 1C-630 sq mm Nos. 190 136

ii) 1C-185 sq mm Nos. 65 46

iii) 3C-150 sq mm Nos. 200 144

6.3 3.3 KV ARMOURED HT.XLPE POWER CABLE

i) 3C-150 sq mm Nos. 6 4

7.0 LT POWER CABLE TERMINATION FOR

7.1 1.1 KV UNARMOURED ALUMINIUM PVC FRLS POWER CABLES

i) 2C‐10 Sq. mm Nos 250 175

ii) 2C‐25 Sq. mm Nos 120 84

iii) 2C‐95 Sq. mm Nos 40 28

(iv) 3C‐10 Sq. mm Nos 800 560

(v) 3C‐25 Sq. mm Nos 600 420

(vi) 3C‐50 Sq. mm Nos 150 105

(vii) 3C‐95 Sq. mm Nos 140 98

(viii) 3.5C‐25 Sq. mm Nos 400 280

(ix) 3.5C‐50 Sq. mm Nos 70 49

(x) 3.5C‐95 Sq. mm Nos 90 63

(xi) 4C‐10 Sq. mm Nos 100 70

(xii) 1C‐35 Sq. mm Nos 100 70

(xiii) 1C‐120 Sq. mm Nos 100 70

7.2 1.1 KV UNARMOURED ALUMINIUM XPLE FRLS POWER CABLES

i) 01C X 400 Sq. mm Nos 800 560

ii) 01C X 630 Sq. mm Nos 1000 700

iii) 03C X 150 Sq. mm Nos 80 56

(iv) 03C X 240 Sq. mm Nos 25 18

(v) 3.5C X 185 Sq. mm Nos 60 42

7.3 1.1 KV ARMOURED ALUMINIUM PVC FRLS POWER CABLES

i) 3.5C‐25 Sq. mm Nos 80 56

ii) 3.5C‐50 Sq. mm Nos 50 35

7.4 1.1 KV ARMOURED COPPER PVC FRLS POWER CABLES

i) 3C‐2.5 Sq. mm Nos 200 140

7.5 1.1 KV UNARMOURED COPPER PVC FRLS POWER CABLES

i) 2C‐2.5 Sq. mm Nos 2000 1400

ii) 3C‐2.5 Sq. mm Nos 4500 3100

iii) 2C‐6 Sq. mm Nos 200 140

8.0 CONTROL CABLE TERMINATION FOR

8.1 1.1 KV UNARMOURED COPPER PVC FRLS CONTROL CABLES

i) 3C X 1.5 Sq. mm Nos 1000 700

ii) 5C X 1.5 Sq. mm Nos 100 70

iii) 5C X 2.5 Sq. mm Nos 500 350

(iv) 7C X 1.5 Sq. mm Nos 500 350

(v) 12C X 1.5 Sq. mm Nos 200 140

(vi) 12C X 2.5 Sq. mm Nos 300 210

(vii) 19C X 1.5 Sq. mm Nos 100 70

9.0 225V SCREENED CABLE TERMINATION (INCLUDING SUPPLY OF LUGS)

i) 4P, 0.5 Nos. 1800 1260

ii) 8P, 0.5 Nos. 350 245

iii) 12P,0.5 Nos. 220 150

iv) 24P, 0.5 Nos. 100 70

10.0 225V SCREENED CABLE TERMINATION (EXCLUDING SUPPLY OF LUGS)

i) 4P, 0.5 Nos. 7200 5040

ii) 8P, 0.5 Nos. 1400 980

iii) 12P,0.5 Nos. 880 620

iv) 24P, 0.5 Nos. 400 280

11.0 CABLE JOINTS

11.1 11 KV UNARMOURED HT. XLPE POWER CABLE

i) 1C-300 sq mm Nos. 34 24

11.2 3.3 KV UNARMOURED HT.XLPE POWER CABLE

i) 3C-150 sq mm Nos. 50 34

11.3 1.1 KV UNARMOURED LT.XLPE POWER CABLE

i) 3C-240 sq mm Nos. 2 1

ii) 3C-150 sq mm Nos. 3 2

12.0 RIGID GALVANISED MS CONDUITS / PIPES

i) 100 mm diameter Metres 1000 700

ii) 75 mm diameter Metres 1000 700

iii) 50 mm diameter Metres 2000 1400

(iv) 25 mm diameter Metres 1000 700

(v) 20 mm diameter Metres 1000 700

13.0FLEXIBLE CONDUITS MADE OF COLD ROLLED ANNEALED ELECTRO

GALVANISED MS STRIP

i) 25 mm diameter Metres 2000 1400

(ii) 18 mm diameter Metres 1000 700

1x 500 MW FGUTPP STAGE IV

BILL OF MATERIAL FOR CABLING, EARTHING AND LIGHTNING PROTECTION SYSTEMS (INSTALLATION)

14.0 PVC Conduitsi) 250 mm diameter Metres 100 70ii) 200 mm diameter Metres 100 70iii) 100 mm diameter Metres 100 70(iv) 50 mm diameter Metres 100 70

15.0ABOVE GROUND EARTHING AND LIGHTNING PROTECTION

MATERIAL

15.1INSTALLATION OF VERTICAL AIR TERMINATION (20 MM DIA GALVANISED MS

ROD 1000 MM LONG)Nos. 100 70

15.2 EARTH CONTINUITY CONNECTION CONDUCTOR

i) GALVANISED MS FLAT 65 X 8 Metres 8000 5600

ii) GALVANISED MS FLAT 50 X 6 Metres 600 420

iii) GALVANISED MS FLAT 25 X 6 Metres 2200 1540

(iv) G S WIRE 8 SWG Metres 5000 3500

15.3 RUNWAY CONDUCTOR

i) 65X8 GALVANISED MS FLAT Metres 13000 9100

15.4INSTALLATION OF HORIZONTAL AIR TERMINATION ON WEATHER PROOFED

SURFACES GALVANISED MS STRIP

i) 25 X 6 mm Metres 5000 3500

15.5INSTALLATION OF HORIZONTAL AIR TERMINATION ON OTHER SURFACES

GALVANISED MS STRIP

i) 25 X 6 mm Metres 500 350

15.6INSTALLATION OF DOWN CONDUCTOR

( 25 X 6 MM GALVANISED MS STRIP)

i) 25 X 6 mm Metres 3500 2450

16.0 JUNCTION BOX (i) 6 WAY Nos. 10 7(ii) 12 WAY Nos. 25 17(iii) 24 WAY Nos. 20 14(iv) 36 WAY Nos. 10 7(v) 48 WAY Nos. 10 7

Item.No Item Description Unit Order Quantity

Unit Erection & Commissio

ning Charges in

INR

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufactur

ed only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection & Commissio

ning Charges

INR

Service tax @ including cess on E & C in INR

Total E & C prices

including Service Tax

in INR

1 Earthwork in excavation & back filling CU. M 1

2 Supply & filling of sand CU. M 1

3 Supply and installation of protective concrete covering CU. M 1

4 Minor civil works

(i) Making opening in brick wall CU. M 1

(ii) Making opening in concrete floor / wall CU. M 1

(iii) Making opening in concrete through core drilling CU. M1

(iv)Making (Constricting into smaller openings already existing large openings) in brickwork CU. M 1

(v)Making (Constricting into smaller openings already existing large openings) in Concrete CU. M 1

(vi) Supply and spreading of bricks CU. M 1

5 Installation of earth electrode driven into earth Nos.1

6 Installation of test pit Nos. 17 Installation of risers Nos. 1

8 Iinstallation of submat in floor Metres 19 Steel fabrication Sq. m 1

1 X 500 MW FGUTPP STAGE IV

BILL OF MATERIAL FOR CABLING, EARTHING AND LIGHTNING PROTECTION SYSTEMS (INSTALLATION)

ANNEXURE 4B-SCHEDULE OF UNIT PRICES

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

5. FIRE SEALING SYSTEM

SL.NO. DESCRIPTION UNIT ORDER QTY. LOT 1 QTY Unit Ex-works price/Unit

Price

Total Ex-Works Price

duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufacture

d only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including

cess on E & C in INR

Total E & C prices

including Service Tax

in INR

Total Supply and E&C in

INR

MAIN ITEMS (IN RUPEES) (IN RUPEES)1 FSS-TYPE A FLOOR OPENINGS

BELOW PANELS (FLOOR THICKNESS 190 MM APPROX)

SQM

170 120

2 FSS-TYPE B FLOOR OPENINGS BELOW PANELS (FLOOR THICKNESS 190 MM APPROX)

SQM

620 440

3 FSS-TYPE B FLOOR OPENINGS (FLOOR THICKNESS 190 MM APPROX)

SQM120 90

4 FSS-TYPE B WALL OPENINGS (WALL THICKNESS 250 MM APPROX) SQM

100 70

5 FSS TYPE-B PIPE SLEEVES (250 NB)NOS

350 245

6TOOLS AND ACCESSORIES REQUIRED FOR ADDITION OR REMOVAL OF CABLES AFTER THE SEAL IS MADE. THIS SHALL INCLUDE SPECIAL TOOLS, COMPOUND INJECTION GUNS, SPRAY GUNS, ETC. (As applicable)

SET

1 1

Notes:-

1)

2)

3)

4)

5)

FEROZ GANDHI UNCHAHAR TPPSTAGE-IV( 1 X 500MW)

ANNEXURE -5A

BILL OF QUANTITIES/ PRICE SCHEDULE FOR SUPPLY OF FIRE SEALING SYSTEM

Successful bidder is responsible for estimation of additional quantities based on site conditions and work progress. The estimates shall be used by NBPPL as inputs for clearing further quantities. These activities shall be completed within the overall contractual period.

Unit prices for supply shall be quoted in line with clause no. 8.3, Section D of Part B of specification.

LOT 1 Quantity shall be released along with LOI, which is approximately 70% of the ordered Quantity/Contract value.

The fire sealing area indicated under Column “Ordered Quantity” above shall be considered for ordering purposes. Bidder shall indicate the quantity of material required to be supplied per square metre, which shall be used for billing purposes of the supply portion after review and acceptance. However, the vendor shall supply the actual material necessary for meeting the specified area requirements as per type-tested arrangement without any commercial implication.

LOT 1 quantities shall be cleared for supply along with the LOI/ PO. However, supplies of quantities shall be made only after approval of drawings, datasheets, quality documentation and successful completion of type testing (if required).

s. no. DESCRIPTION UNIT ORDER QTY. LOT 1 QTY Unit Erection &

Commissioning Charges

in INR

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufac

tured only

Freight including Service tax @

Total FOR Site

Price (Supply) in INR

Total Erection

& Commiss

ioning Charges

INR

Service tax @

including cess on E & C in

INR

Total E & C prices

including Service Tax in INR

MAIN ITEMS1 FSS-TYPE A FLOOR OPENINGS

BELOW PANELS (FLOOR THICKNESS 190 MM APPROX)

SQM

170 120

2 FSS-TYPE B FLOOR OPENINGS BELOW PANELS (FLOOR THICKNESS 190 MM APPROX)

SQM

620 440

3 FSS-TYPE B FLOOR OPENINGS (FLOOR THICKNESS 190 MM APPROX)

SQM120 90

4 FSS-TYPE B WALL OPENINGS (WALL THICKNESS 250 MM APPROX)

SQM100 70

5 FSS TYPE-B PIPE SLEEVES (250 NB) NOS

350 245

Notes‐

1

3

3

FEROZ GANDHI UNCHAHAR TPPSTAGE-IV( 1 X 500MW)

ANNEXURE- 5A

BILL OF QUANTITIES/ PRICE SCHEDULE FOR INSTALLATION OF FIRE SEALING SYSTEM

Unit prices for installation shall be quoted in line with clause no. 8.3, Section D of Part B of specification.

Successful bidder is responsible for estimation of additional quantities based on site conditions and work progress. 

The estimates shall be used by NBPPL as inputs for clearing further quantities.  These activities shall be completed 

within the overall contractual period. 

LOT 1 Quantity shall be released along with LOI, which is approximately 70% of the ordered Quantity/Contract 

value.

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

6. HT XLPE CABLES

Unit Ex-works

price/Unit Price

Total Ex-Works

Price duly packed in INR/Total

Price.

Excise Duty @ on

self manufactu

red only

VAT/CST @ … in

INR on self manufactu

red only

Freight including Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection & Commissi

oning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply

and E&C in INR

1.1 3C – 150Sq. mm

4500 Meters

3500 Meters

500 Meters

1.2 1C – 300Sq. mm

13000 Meters

10000 Meters

500 Meters

1.3 1C – 630Sq. mm

3000 Meters

2000 Meters

500 Meters

Unit Ex-works

price/Unit Price

Total Ex-Works

Price duly packed in INR/Total

Price.

Excise Duty @ on

self manufactu

red only

VAT/CST @ … in

INR on self manufactu

red only

Freight including Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection & Commissi

oning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply

and E&C in INR

2.1 3C –150Sq. mm

33000 Meters

23000 Meters

500 Meters

2.2 1C –185Sq. mm

3000 Meters

2500 Meters

500 Meters

2.3 1C –630Sq. mm

5000 Meters

4000 Meters

500 Meters

Unit Ex-works

price/Unit Price

Total Ex-Works

Price duly packed in INR/Total

Price.

Excise Duty @ on

self manufactu

red only

VAT/CST @ … in

INR on self manufactu

red only

Freight including Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection & Commissi

oning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply

and E&C in INR

3.1 3C –150Sq. mm

500Meters

500 Meters

500 Meters

Notes:

11/11 kV unarmoured cables

3.3/3.3 kV unarmoured cables

3.3/3.3 kV armoured cables

Sl. No. Cable Sizes

Total Quantity

Sl. No. Cable Sizes

Total Quantity

LOT-1 Quantity

Drum Length

Supply

1. Total Quantities indicated above shall be known as Order Quantities.

2. The bidder shall indicate the unit price of each type and size of cables listed as per the BOQ in the Price Schedule enclosed with this specification. The unit prices shall apply for adjustment of variation in quantity as stipulated above.

LOT-1 Quantity

Drum Length

Supply

Sl. No. Cable Sizes

Total Quantity

LOT-1 Quantity

Drum Length

Supply

3. Lot-I quantities indicated above (in case the cable quantities are to be released for manufacture in more than one lot), or Order Quantity (in case the quantities are cleared for manufacture in one lot only) shall be cleared for manufacturing along with LOI. However, manufacturing of the cables shall be taken up by the successful bidder only after approval of technical and quality documentation and shall be completed within four months from the date of approval of documentation. Subsequent lots shall be cleared for manufacture based on progress of engineering and site requirements. A lead-time of three months shall be

4. The standard drum length for power cables shall not be less than 500 meters. The length per drum shall be subjected to a maximum tolerance of +/- 5% of the standard drum length. Customer shall have the option of rejecting cable drum with shorter lengths.

5. Overall tolerance on total dispatched quantity of each size shall be (-) 2% and (+) 0% Cables consumed for testing and inspection shall be to bidder’s account.

6. For each individual cable size, one short length of not less than 200m may be accepted only in the final drum length to complete the supply (except where the total ordered quantity is one single drum length of 500m). The overall tolerance limits stipulated above shall continue to apply (in case short lengths are accepted).

7. Bidder shall indicate unit price of cables inclusive of type test charges. No separate charges shall be payable for type tests.

Bill of Quantities(Main Items) Annexure 6

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

7A. 1.1 kV XLPE POWER AND PVC POWER CABLES

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on

E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on

E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

DRUM LENGTH

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on

E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

500 METER500 METER

DRUM LENGTH

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on

E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

1000 METER

1100 V grade, power cables with stranded compacted plain Aluminium conductor (H2 grade, class 2) , XLPE insulated, PVC type ST2 extruded inner sheathed (no inner sheath for single core cables) and extruded PVC Type ST2 outer sheath with FRLS properties, generally conforming to IS:7098 (Part-1) and NBPPL specification.

1100 V grade power cables with stranded aluminium conductor, PVC Type-A insulation, core identification by colour coding, distinct extruded inner sheath of PVC Type ST2 material (for multi-core cables only) and extruded PVC type ST2 outer sheath with FRLS properties, generally conforming to IS:1554 (Part-1).

1100 V grade power cables with tinned copper conductor, PVC Type-A insulation, core identification by colour coding, distinct extruded inner sheath of PVC Type ST2 material, aluminium wire armour for single core cables and GS round wire/ formed wire armour (Type-'b') for multicore cables, and extruded PVC type ST2 outer sheath with FRLS properties, generally conforming to IS:1554 (Part-1). Colour of the outersheath shall be YELLOW.

(A): UNARMOURED ALUMINIUM PVC FRLS POWER CABLES

S. NO.

SIZE (IN SQ.MM.) QUANTITY (km.)

LOT-1 QTY (km.) DRUM LENGTH

1 2C-10 7 5 500 METER2 2C-25 10 7 500 METER3 2C-95 8 6 500 METER4 3C-10 19 14 500 METER5 3C-25 18 13 500 METER6 3C-50 14 10 500 METER7 3C-95 8 6 500 METER8 3.5C-25 7 5 500 METER9 3.5C-50 29 20.5 500 METER

10 3.5C-95 4 3 500 METER11 4C-10 2 1 500 METER12 1C-35 3 2 500 METER13 1C-120 8 6 500 METER

S. NO.

SIZE (IN SQ.MM.) QUANTITY (km.)

(B): UNARMOURED ALUMINIUM XPLE FRLS POWER CABLES

LOT-1 QTY (km.) DRUM LENGTH

1 01C X 400 21.5 15 500 METER2 01C X 630 16.5 12 500 METER

5 3.5C X 185 4 3 500 METER(C): ARMOURED ALUMINIUM PVC FRLS POWER CABLES

3 03C X 150 4.5 3.5 500 METER4 03C X 240 15 11 500 METER

SIZE (IN SQ.MM.) QUANTITY (km.) LOT-1 QTY (km.)1 3.5C-25 4 3

S. NO.

1100 V grade power cables with stranded aluminium conductor, PVC Type-A insulation, core identification by colour coding, distinct extruded inner sheath of PVC Type ST2 material, aluminium wire armour for single core cables and GS round wire/ formed wire armour (Type-'b') for multicore cables, and extruded PVC type ST2 outer sheath with FRLS properties, generally conforming to IS:1554 (Part-1).

(D): ARMOURED COPPER PVC FRLS POWER CABLES

S. NO. SIZE (IN SQ.MM.) QUANTITY (km.) LOT-1 QTY (km.)

2 3.5C-50 2.5 2

1 3C-2.5 20 14

ANNEXURE 7AA

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on

E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

5.            For each individual cable size, one short length of not less than 200m may be accepted only in the final drum length to complete the supply (except where the total ordered quantity is one single drum length of 500m). The overall tolerance limits stipulated above shall continue to apply (in case short lengths are accepted).

6.            Bidder shall indicate unit price of cables inclusive of type test charges. No separate charges shall be payable for type tests.

7.            The standard drum length shall be 500 meters for Aluminium Cables and 1000m for Copper Cables. Tolerance on individual drum length shall be ±5%.

1.            Quantities indicated above shall be known as Order Quantities.

2.            The bidder shall indicate the unit price of each type and size of cables listed as per the BOQ in the Unit Price Schedule enclosed with this specification. The unit prices shall apply for adjustment of variation in quantity as stipulated above.

3.            Lot-I quantities indicated above (in case the cable quantities are to be released for manufacture in more than one lot), or Order Quantity (in case the quantities are cleared for manufacture in one lot only) shall be cleared for manufacturing along with LOI. However, manufacturing of the cables shall be taken up by the successful bidder only after approval of technical and quality documentation and shall be completed within four months from the date of approval of documentation. Subsequent lots shall be cleared for manufacture based on progress of engineering and site requirements. A lead-time of three months shall be given for completion of supply for each subsequent lot from the date of clearance of the quantities.

4.            Overall tolerance on total dispatched quantity of each size shall be (-) 2% and (+) 0%. Cables consumed for testing and inspection shall be to bidder’s account.

1100 V grade power cables with stranded tinned copper conductor, PVC Type-A insulation, core identification by colour coding , distinct extruded inner sheath of PVC Type ST2 material (for multicore cables only) and extruded PVC type ST2 outer sheath with FRLS properties, generally conforming to IS:1554 (Part-1).

(E): UNARMOURED COPPER PVC FRLS POWER CABLES

S. NO.

SIZE (IN SQ.MM.) QUANTITY (km.)

LOT-1 QTY (km.) DRUM LENGTH

1000 METER

NOTES :

1 2C-2.5 16 11 1000 METER2 3C-2.5 137 96 1000 METER3 2C-6 19 14

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

7B. 1.1 kV PVC CONTROL CABLES

S. NO. QUANTITY (km.)

LOT-1 QTY (km.) DRUM LENGTH Unit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in INR

Total Supply and E&C in INR

1 48 34 1000 METER2 3 2 1000 METER3 21 15 1000 METER4 25 18 1000 METER5 3 2 1000 METER6 4 3 1000 METER7 1 1 1000 METER

(A): UNARMOURED COPPER PVC FRLS CONTROL CABLES

'Control cables are of 1100 V earthed grade with stranded plain annealed copper conductor, PVC Type-A insulation, core identification by colour coding (upto five cores)/ number marking (more than five cores), distinct extruded inner sheath of PVC Type ST1 material, GS formed wire armour as per IS: 3975 (armour provided for directly buried cables only) and extruded PVC type ST1 outer sheath with FRLS properties, generally conforming to IS:1554 (Part-1). Maximum conductor temperature for normal operation is 70 deg. C and for short circuit conditions, 160 deg. C. The minimum conductor cross section is 1.5 sq. mm.

12C X 2.519C X 1.5

SIZE (IN SQ.MM.)

3C X 1.55C X 1.5

7C X 1.512C X 1.5

5C X 2.5

ANNEXURE 7AB

1. Quantities indicated above shall be known as Order Quantities. 2. The bidder shall indicate the unit price of each type and size of cables listed as per the BOQ in the Unit Price Schedule enclosed with this specification. The unit prices shall apply for adjustment of variation in quantity as stipulated above.

3. Lot-I quantities indicated above (in case the cable quantities are to be released for manufacture in more than one lot), or Order Quantity (in case the quantities are cleared for manufacture in one lot only) shall be cleared for manufacturing along with LOI. However, manufacturing of the cables shall be taken up by the successful bidder only after approval of technical and quality documentation and shall be completed within four months from the date of approval of documentation. Subsequent lots shall be cleared for manufacture based on progress of engineering and site requirements. A lead-time of three months shall be given for completion of supply for each subsequent lot from the date of clearance of the quantities.

4. Overall tolerance on total dispatched quantity of each size shall be (-) 2% and (+) 0%. Cables consumed for testing and inspection shall be to bidder’s account.

5. For each individual cable size, one short length of not less than 200m may be accepted only in the final drum length to complete the supply (except where the total ordered quantity is one single drum length of 500m). The overall tolerance limits stipulated above shall continue to apply (in case short lengths are accepted). 6. Bidder shall indicate unit price of cables inclusive of type test charges. No separate charges shall be payable for type tests.7. The standard drum length shall be 1000m for Copper Cables. Tolerance on individual drum length shall be ±5%.

NOTES :

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

8. SCREENED CONTROLCABLES

(A):

S.No. SIZE IN SQ. MM Order Quantity (Km) LOT 1 Quantity (Km)Drum Length (Meters)

Unit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on

self manufactur

ed only

VAT/CST @ … in

INR on self manufactur

ed only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection & Commissio

ning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices

including Service

Tax in INR

Total Supply and E&C in

INR

1 4P, 0.5 103 722 8P,0.5 31 223 12P, 0.5 12.5 94 24P,0.5 10 7

(B):

Total Ex- Excise VAT/CST Total Service tax Total E & C

SCREENED CONTROL CABLE ANNEXURE-8A: BOQ/ PRICE SCHEDULE

500

TYPE 'G', 0.5 SQ. MM. CABLES: Multi pair (twisted) overall shielded instrumentation cables.

225 volt peak, multi-pair (twisted) instrumentation cables, 0.5 sq. mm. high conductivity, electrolytic, Annealed bare, multi stranded copper conductor as per VDE 0815, extruded PVC (compound YI3) insulation as per VDE 0207 Part-4, core & pair identification by suitable colour coding & band marking as per VDE 0815, stranded tin coated copper conductor drain wire, overall shielded with aluminium mylar tape, extruded PVC (compound YM1) outer sheath (sky blue) as per VDE 0207 Part-5 and VDE 0816 with FRLS properties.

225 volt peak, multi-pair (twisted) instrumentation cables, 0.5 sq. mm. high conductivity, electrolytic, Annealed bare, multi stranded copper conductor as per VDE 0815, extruded PVC (compound YI3) insulation as per VDE 0207 Part-4, core & pair identification by suitable colour coding & band marking as per VDE 0815, individual pair and overall shielded with aluminium mylar tape, stranded tin coated copper conductor drain wire provided separately for both individual pair & overall shielding, extruded PVC (compound YM1) outer sheath (sky blue) as per VDE 0207 Part-5 and VDE 0816 with FRLS properties.

100010001000

TYPE 'F' , 0.5 SQ. MM.CABLES: Multi pair (twisted) individual & overall shielded instrumentation cables.

S.No. SIZE IN SQ. MM Order Quantity (Km) LOT 1 Quantity (Km)

Unit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on

self manufactur

ed only

VAT/CST @ … in

INR on self manufactur

ed only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection & Commissio

ning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices

including Service

Tax in INR

Total Supply and

E&C Rs

1 4P, 0.5 206 144. 2 8P, 0.5 30 21

3 12P, 0.5 31 21

NOTES:

1

2

3

4

5

6

7

100010001000

Drum Length (Meters)

Overall tolerance on total dispatched quantity of each size shall be (-) 2% and (+) 0%. Cables consumed for testing and inspection shall be to bidder ’s account

The tolerance of drum length shall be + 5%. Short lengths of individual cable size not less than 300m may be accepted only in the final drum length to complete the supply within the overall variation limits stipulated above.

Lot-I quantities indicated above (in case the cable quantities are to be released for manufacture in more than one lot), or Order Quantity (in case the quantities are cleared for manufacture in one lot only) shall be cleared for manufacturing along with LOI. However, manufacturing of the cables shall be taken up by the successful bidder only after approval of technical and quality documentation and shall be completed within four months from the date of approval of documentation. Subsequent lots shall be cleared for manufacture based on progress of engineering and site requirements. A lead-time of three months shall be given for completion of supply for each subsequent lot from the date of clearance of the quantities.

Quantities indicated above shall be known as Order Quantities.

The bidder shall indicate the unit price of each type and size of cables listed as per the BOQ in the Unit Price Schedule enclosed with this specification. The unit prices shall apply for adjustment of variation in quantity as stipulated above.

In case the quantities of any one lot cleared by NBPPL for manufacturing are manufactured and offered for inspection by successful bidder in more than one batch, NBPPL reserves the right to witness type testing on all batches.

Bidder shall indicate unit price of cables inclusive of type test charges. No separate charges shall be payable for type tests.

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

9. 220 V DC BATTERY

Sr. No. Item code Item Description Unit Quantity Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on

self manufactur

ed only

VAT/CST @ … in INR

on self manufactur

ed only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection & Commissio

ning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices

including Service

Tax in INR

Total Supply and

E&C in INR

(A) MAIN ITEMS

1.0

NI-CD POCKET PLATE 220V BATTERY (169 CELLS,220V Ni-Cd, HIGH discharge battery 1.14 ECVsuitable as per Load Duty Cycle( Annexure-III) with all accessories & MS racks with 3 coats of anti acidpaints.(For each battery))

Sets 2

Break up detail

220V , Ni-Cd battery suitable as per Load Duty Cycle(Annexure-III) ( 1 set comprises 170 nos. cell) Sets 2

MS racks with 3 coats of anti acid paints for 220V DCBattery Sets 2

Intercell connectors Sets 2

Electrolyte (sulphuric acid for first filling plus10%extra ) Sets 2

1.1LIST OF ACCESSORIES (for each set of battery)

a Hydrometer Nos 2

bSet of hydrometer syringes (suitable for the ventholes in different cells) Nos 2

cThermometer with specific gravity correction scale(for measuring electrolyte temperature) Nos 5

d Specific gravity correction chart Nos 2

e Wall mounting type holder made of teak wood for hydrometer and thermometer

Nos 2

f Cell testing digital voltmeter (3-0-3V) with testing leads

Nos 2

g Acid/alkali mixing jar Nos 2

h Rubber apron Nos 2

i Pair of rubber hand gloves Nos 2

j Set of spanners Nos 2

k `No smoking’ notice Nos 2

l Goggles (industrial) Nos 2

m Instruction card Nos 10

n Minimum and maximum temperature indicator forBattery Room

Nos 1

o Interconnector bolt wrenches Nos 1

p Stand insulators lot 1

q Battery log book Nos 1

r Funnel Nos 2

s Multimeter Nos 2

t Cell interconnectors with 5% extra and end take-off with one no. extra

lot 1

u Lead coated connection hardware plus 5% extra lot 1

v Teakwood Cable clamps with hardware lot 1

2.0 E & C SPARES

FEROZ GANDHI UNCHAHAR TPP STAGE-IV( 1 X 500MW) ANNEXURE-9B (OPTION-1)BOQ-cum-PRICE SCHEDULE FOR 220V DC BATTERY (NI-CD Battery)

Page 1 of 2

123
Text Box

FEROZ GANDHI UNCHAHAR TPP STAGE-IV( 1 X 500MW) ANNEXURE-9B (OPTION-1)BOQ-cum-PRICE SCHEDULE FOR 220V DC BATTERY (NI-CD Battery)

a INTER CELL CONNECTOR NOS 2

b GLOVES SET 2

c VENT PLUGS NOS 2

3.0 MANDATORY SPARES

COMPLETELY ASSEMBLED CELL (DRY)NOS.

2% or 2 Nos. whichever is more

Intercell connectors with hardwareNOS./%

10% or 5 nos. whichever ismore of total population of2 sets of battery

Vent plugNOS./%

10% or 5 nos. whichever ismore of total population of2 sets of battery

Acid level indicating float (for opaque containers only)NOS./%

10% or 5 nos. whichever ismore of total population of2 sets of battery

Stand insulatorNOS./%

10% or 5 nos. whichever ismore of total population of2 sets of battery

Cell insulatorNOS./%

10% or 5 nos. whichever ismore of total population of2 sets of battery

Note: A)Cable Lugs at Battery terminals shall be in bidders Scope & Same shall be informed during detailed engineering. B) Bidder can quote for either Option-1 or Option-2

Page 2 of 2

123
Text Box

Sr. No. Item code Item Description Unit Quantity Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR (6+7+8+9)

Total Erection & Commissioning Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax (11+12) in INR

Total Supply and E&C in INR

(A) MAIN ITEMS

1.0

LEAD -ACID BATTERY PLANTE, 220V BATTERY (107CELLS, 220V LEAD ACID, 1.85 ECV suitable as perLoad Duty Cycle(Annexure-III ) with all accessories& Teakwood racks with 3 coats of anti acidpaints.(For each battery set)

Sets 2

Break up detail 2

220V , Lead acid plante battery suitable as perAnnexure-III (Load duty cycle) (1 set comprises 107nos cell)

Sets 2

Teakwood racks with 3 coats of anti acid paints for220V DC Battery Sets 2

Intercell connectors Sets 2

Electrolyte (sulphuric acid for first filling plus10%extra ) Sets 2

1.1LIST OF ACCESSORIES (for each set ofbattery)

a Hydrometer Nos 2

bSet of hydrometer syringes (suitable for the ventholes in different cells) Nos 2

cThermometer with specific gravity correction scale(for measuring electrolyte temperature) Nos 5

d Specific gravity correction chart Nos 2

e Wall mounting type holder made of teak wood for hydrometer and thermometer

Nos 2

f Cell testing digital voltmeter (3-0-3V) with testing leads

Nos 2

g Acid/alkali mixing jar Nos 2

h Rubber apron Nos 2

i Pair of rubber hand gloves Nos 2

j Set of spanners Nos 2

k `No smoking’ notice Nos 2

l Goggles (industrial) Nos 2

m Instruction card Nos 10

n Minimum and maximum temperature indicator forBattery Room

Nos 1

o Interconnector bolt wrenches Nos 1

p Stand insulators lot 1

q Battery log book Nos 1

r Funnel Nos 2

s Multimeter Nos 2

FEROZ GANDHI UNCHAHAR TPP STAGE-IV( 1 X 500MW) ANNEXURE-9B (OPTION-2)BOQ-cum-PRICE SCHEDULE FOR 220V DC BATTERY (LEAD -ACID PLANTE)

Page 1 of 2

123
Text Box

FEROZ GANDHI UNCHAHAR TPP STAGE-IV( 1 X 500MW) ANNEXURE-9B (OPTION-2)BOQ-cum-PRICE SCHEDULE FOR 220V DC BATTERY (LEAD -ACID PLANTE)

t Cell interconnectors with 5% extra and end take-off with one no. extra

lot 1

u Lead coated connection hardware plus 5% extra lot 1

v Teakwood Cable clamps with hardware lot 1

2.0 E & C SPARES

a INTER CELL CONNECTOR NOS 2

b GLOVES SET 2

c VENT PLUGS NOS 2

3.0 MANDATORY SPARES

COMPLETELY ASSEMBLED CELL (DRY)NOS.

2% or 2 Nos. whichever is

Intercell connectors with hardwareNOS./%

10% or 5 nos.whichever is

f lVent plugNOS./%

10% or 5 nos.whichever ismore of total

Acid level indicating float (for opaque containers only) NOS./%

10% or 5 nos.whichever ismore of total

Stand insulatorNOS./%

10% or 5 nos.whichever ismore of total

Cell insulatorNOS./%

10% or 5 nos.whichever ismore of total

Note: A)Cable Lugs at Battery terminals shall be in bidders Scope & Same shall be informed during detailed engineering. B) Bidder can quote for either Option-1 or Option-2

Page 2 of 2

123
Text Box

Sr. No. Item Description Unit QuantityUnit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E

& C in INR

Total E & C prices including Service Tax

in INR

Total Supply and E&C in INR

1

LEAD -ACID BATTERYPLANTE, 220V BATTERY(107 CELLS, 220V LEADACID, 1.81 ECV suitable asper Load Duty Cycle(pl referPART-B of technicalspecification ) with allaccessories & Teakwoodracks with 3 coats of anti acidpaints.(For each battery set)

Sets 2

Break up detail 2220V , Lead acid plantebattery suitable as per Loadduty cycle. (1 set comprises107 nos cell)

Sets 2

Teakwood racks with 3 coatsof anti acid paints for 220VDC Battery

Sets 2

Intercell connectors Sets 2Electrolyte (sulphuric acid forfirst filling plus10% extra ) Sets 2

                                                       Annexure‐9AUNPRICED PRICE SCHEDULE E & C FOR 220V DC BATTERY (Lead-Acid Plante Battery) (OPTION-2)

Note: Bidder can quote for either Option-1 or Option-2

Sr. No. Item Description Unit QuantityUnit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E

& C in INR

Total E & C prices including Service Tax

in INR

Total Supply and E&C in INR

1

NI-CD POCKET PLATE 220VBATTERY (169 CELLS, 220VNi-Cd, HIGH discharge battery1.14 ECV suitable as per LoadDuty Cycle(pl refer PART-B oftechnical specification) with allaccessories & MS racks with3 coats of anti acid paints.(Foreach battery))

Sets 2Break up detail220V , Ni-Cd battery suitableas per Load Duty Cycle ( 1 setcomprises 170 nos. cell)

Sets 2MS racks with 3 coats of antiacid paints for 220V DCBattery Sets 2Intercell connectors Sets 2Electrolyte (sulphuric acid forfirst filling plus10% extra )

Sets 2

UNPRICED PRICE SCHEDULE E & C FOR 220V DC BATTERY (Ni-Cd Battery) (OPTION-1)

Note: Bidder can quote for either Option-1 or Option-2

                                                        Annexure‐9A

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

10. 220 V DC BATTERY CHARGER

FEROZ GANDHI UNCHAHAR TPP STAGE-IV( 1 X 500MW) ANNEXURE 9C

Sr. No. Item Description Unit QuantityRemarks

Unit Ex-works price/Unit PriceTotal Ex-Works Price

duly packed in INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including cess

on E & C in INR

Total E & C prices

including Service Tax in

INR

Total Supply and E&C in

INR

1 FLOAT-CUM-BOOST CHARGER1 NOS 2 400A, 220V DC Float-cumboost

2 BATTERY FUSE BOX NOS 2Battery fuse suitable as per Load Duty Cycle (Annexure-VI)

3 DISCHARGE RESISTOR NOS 1 Variable mettalic resistor and shunt for 220V DC, 920AH Ni-Cd battery for 5 hr. discharge rate/ 1500AH Lead acid plante battery for 10 hr. discharge rate

4 E & C SPARES LOT 14.1 FUSE LINK WITHOUT HOLDERa AC I/P HRC FUSE LINK NOS 2b GLASS FUSE NOS 2c CONTROL HRC FUSE LINK NOS 2d RECTIFIER FUSE LINK NOS 2e FILTER CAPACITOR FUSE LINK NOS 2f DC O/P FUSE LINK NOS 2

4.2 INDICATING LAMPAC I/P LAMP RED COLOR NOS 2AC I/P LAMP YELLOW COLOR NOS 2AC I/P LAMP BLUE COLOR NOS 2DC O/P LAMP NOS 2

5 MANDATORY SPARES LOT 1

5.1ELECTRONIC CARDS (ALLCOMPONENTS MOUNTED)

5.1.1

Set of Cards and modules (Each type and rating: CPC Card, HV PFPSR card, Rectifier FFD card, DC under/over voltage relay card, ACOR card, DC output fuse FFD card, Earth leakage card,etc.)

SET 1

5.1.2

Set of Auxiliary relays (Each type and rating: Auxiliary relays, 6 amp/ 110 V DC coil and 6 amp/240 V AC coil)

SET 1

5.1.3

Set of fuse links and glass fuses(Each type and rating:AC input fuse links, 315 Amp,Rectifier fuse link, GS1000/400 Amp,Filter condenser fuse link, 160 Amp,DC output HRC fuse link, 500 Amp,Control HRC fuses links, 2 &

SETS 3

5.1.4Set of SCR and Diode (One of each type and rating)

SETS 3

5.1.5 Rectifier transformerNos. 1 No. of each type

& rating

5.1.6 Control transformersNos. 1 No. of each type

& rating

BOQ CUM UNPRICED PRICE SCHEDULE FOR SUPPLY OF 220V DC BATTERY CHARGER

                                               FEROZ GANDHI UNCHAHAR TPP STAGE‐IV( 1 X 500MW)                                     ANNEXURE 9C

Sr. No.

Item Description Unit  Quantity

Unit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning Charges in INR

Service tax @ including cess on

E & C in INR

Total E & C prices including Service

Tax in INR

1400A, 220V DC Float-cum boost  NOS  2

2

Battery fuse suitable as per Load Duty Cycle (for load duty cycle , pl refer PART-B of technical specification)

 NOS  2

3

Variable metallic resistor and shunt for 220V DC, Ni-Cd battery for 5 hr. discharge rate/ Lead acid plante battery for 10 hr. discharge rate

 NOS  1

UNPRICED PRICE SCHEDULE E & C FOR 220V DC BATTERY CHARGER

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

11. GENERATOR CIRCUIT BREAKER

SL.NO. ITEM QTY.

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges

INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in INR Total Supply and E&C in INR

1 Generator Circuit Breaker including all associated series isolators, earth-switches, surge capacitors

1 No

2 Start-up and Commissioning Spares(Bidder to furnish the list)

1 No

3 Special Tools and Tackles(Bidder to furnish the list)

1 Set

4 Supervision of Erection, Testing and Commissioning(Refer Note 1 & 2)

1 Set

5 Mandatory Spares(as per Annexure-II)

1 Lot

Notes:

1.    Wherever set is indicated above, it means the total parts/ accessories required to replace the particular item for given equipment.

2.    For item no. 5 (Mandatory spares), bidders to also indicate prices for individual type test/items as per Annexure-II.

3.    Supervision of Erection, Testing and Commissioning shall be performed by original equipment manufacturer.

ANNEXURE 10Supply, Type Test and Supervision of E & C

4.    For Supervision of Erection, Testing and Commissioning, price for 4 man-days & 1 visit shall be quoted for each GCB. The price shall be all inclusive of charges for airfare, boarding/ lodging, visa, medical, insurance etc.

SL. NO. DESCRIPTION QUANTITY

Unit Ex-works

price/Unit Price

Total Ex-Works Price

duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including cess

on E & C in INR

Total E & C prices

including Service Tax in

INR

Total Supply and E&C in

INR

1Complete pole assembly (along with internally mountedequipment) 1 Set

2 Closing coils 3 Nos.3 Tripping coil 3 Nos.4 Closing springs (if applicable) 1 No.5 Tripping springs (if applicable) 1 No.6 Gaskets 1 Set for a breaker7 Limit Switches 1 Set for a breaker8 Bus seal off bushings 1 Set for a breaker

9Upper and lower terminals with finger contact device

1 Set upper & 1 set lower

10 Arc extinction coil 2 Nos.11 SF6 cylinders 3 Nos.12 Auxiliary switches 2 Sets13 Drive assembly complete for GCB 1 Set

14In case of SF6 GCB following shall be provided: 1 Set

a Gas density switch 1 No.b Gas pressure gauge 1 No.c Gas density indicator 1 No.d Absorbent 3 Nos.

eTeflon hoses for one replacement in all the six poles of breakers 1 Set

NOTE: (1) Wherever quantity is mentioned as set bidder to quote for each type & rating.

(2) Bidder to indicate prices for individual items.

PRICE SCHEDULE FOR MANDATORY SPARESANNEXURE –II

SL.NO. ITEM QTY. Unit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges in INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in INR

1

Generator Circuit Breaker including all associated series isolators, earth-switches, surge capacitors

1 No

2

Supervision of 

Erection,Testing and 

Commissioning(Refer Note: 

1&2)

1Set

Notes:

1. Supervision of Erection, Testing and Commissioning shall be performed by original equipment manufacturer.

PRICE SCHEDULE(E&C and Supervision of E&C)

Annexure-10

2. For supervision of Erection,Testing and Commissioning, Price for 4 Mandays & 1Visit shall be quoted for GCB. The price shall be inclusive of charges for Airfare,Boarding/Lodging,Visa,Medical,Insurance etc.

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

12. PA SYSTEM

ANNEXURE-11

Item No.

DESCRIPTION Unit

(A) MAIN EQUIPMENT MAKE MODEL NO.

Unit Ex-works

price/Unit Price

Total Ex-Works Price

duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufactur

ed only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including cess on E & C in INR

Total E & C prices

including Service Tax

in INR

Total Supply and E&C

in INR

1 Central exchange for unit & common area with integrated MDF 1 No.Microprocessor controlled, digital, programmable central control unit(CCU) with PCM/TDM technology suitable for 110 stations and abilityto interconnect 10 more zones for future expansion

2 Central exchange for CHP area with integrated MDF 1 No.Microprocessor controlled, digital, programmable central control unit(CCU) with PCM/TDM technology suitable for 90 stations and ability tointerconnect 10 more zones for future expansion

3 Master Control Station (MCS) 4 Nos.Built-in mic & speaker, LCD display, handset, 4 LED indicators & 18nos. key board switches

4 Flush Mounted Station (FMS) 4 Nos.Built-in mic & speaker, LCD display, handset, 4 LED indicators & 18nos. key board switches

5 Desktop Station with Cone type speaker 20 Nos.

SUPPLY (Rs)QUANTITY

1 X 500 MW FGUTPP STAGE-IV - Bill of Quantity for Main Items for Public Address System

5 Desktop Station with Cone type speaker 20 Nos.Built-in mic & speaker, LCD display, handset, 4 LED indicators & 18nos. key board switches

6 Extension amplifier for MCS, FMS and desktop station 28 Nos.7 Wall/column mounted, weatherproof field call station with handset and

built-in power amplifier,Horn type loudspeaker with 15W (RMS) , for outdoor area (Main & Common plant) conforming to IP-55

60 Nos.

8 Wall/column mounted, weatherproof field call station with handset and built-in power amplifier,Horn type loudspeaker with 15W (RMS) , for outdoor area (CHP area) conforming to IP-65

50 Nos.

9 Wall/column mounted, with handset, built-in power amplifier with horn type speaker 15W (RMS) for indoor area (Main & Common plant) conforming to IP-52

45 Nos.

10 Wall/column mounted, with handset, built-in power amplifier with horn type speaker 15W (RMS) for indoor area (CHP area) conforming to IP-65

25 Nos.

11 Sub-distribution frame (SDF) 24 pairs 35 Nos.12 Portable handset station with multi-pin plug and 25 meter wire 4 Nos.13 Socket box for Portable handset station 10 Nos.14 Wall/ column mounted 4W Cone type loudspeaker 20 Nos.15 Wall/ column mounted 15W Horn type loudspeaker (Main & common

plant area) conforming to IP-55 for outdoor area60 Nos.

ANNEXURE-11

Item No.

DESCRIPTION Unit

(A) MAIN EQUIPMENT MAKE MODEL NO.

Unit Ex-works

price/Unit Price

Total Ex-Works Price

duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufactur

ed only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including cess on E & C in INR

Total E & C prices

including Service Tax

in INR

Total Supply and E&C

in INR

SUPPLY (Rs)QUANTITY

1 X 500 MW FGUTPP STAGE-IV - Bill of Quantity for Main Items for Public Address System

16 Wall/ column mounted 15W Horn type loudspeaker (Main & commonplant area) conforming to IP-52 for indoor area

45 Nos.

17 Wall/ column mounted 15W Horn type loudspeaker (CHP plant area)conforming to IP-65

75 Nos.

18 Power junction box 200 Nos.19 Signal junction box 30 Nos.20 Sound protecting floor mounted Acoustic hood 10 Nos.21 Weather protecting canopy for field call station 110 Nos.22 Power distribution box 2 Nos.23 Special tools & tackles, if any24 Additional item, required for the completeness of system

NOTES:1. Bidder must indicate the make & model number of each item else the offer can not be evaluated.2. The unit rates of supply for all equipment are to be quoted by the bidder.3. Design and engineering charges shall form part of main equipment.4. Charges for special tools & tackles required for the PA system shall form part of main equipment.5. Main equipment Items, which are not applicable for their system, bidder to mention in "Remarks" column and same shall appear in the unpriced5. Main equipment Items, which are not applicable for their system, bidder to mention in "Remarks" column and same shall appear in the unpriced

copy of the bid also.6. Any additional item/equipment required (as per system quoted by the bidder), bidder shall quote it separately with their unit rate.

ANNEXURE-11

Item No.

DESCRIPTION

1 Central exchange for unit & common area with integrated MDF 1 No.

Microprocessor controlled, digital, programmable centralcontrol unit (CCU) with PCM/TDM technology suitable for 110stations and ability to interconnect 10 more zones for futureexpansion

2 Central exchange for CHP area with integrated MDF 1 No.

Microprocessor controlled, digital, programmable centralcontrol unit (CCU) with PCM/TDM technology suitable for 90stations and ability to interconnect 10 more zones for futureexpansion

3 Master Control Station (MCS) 4 Nos.

Built-in mic & speaker, LCD display, handset, 4 LED indicators& 18 nos. key board switches

4 Flush Mounted Station (FMS) 4 Nos.

Built-in mic & speaker, LCD display, handset, 4 LED indicators& 18 nos. key board switches

5 Desktop Station with Cone type speaker 20 Nos.

Built-in mic & speaker, LCD display, handset, 4 LED indicators& 18 nos. key board switches

6 Extension amplifier for MCS, FMS and desktop station 28 Nos.

7 Wall/column mounted, weatherproof field call station with handset and built-in power amplifier,Horn type loudspeaker with 15W (RMS) for outdoor area (Main & Common plant) conforming to IP-55

60 Nos.

8 Wall/column mounted, weatherproof field call station with handset and built-in power amplifier,Horn type loudspeaker with 15W (RMS) for outdoor area (CHP area) conforming to IP-65

50 Nos.

9 Wall/column mounted, with handset, built-in power amplifier with horn type speaker 15W (RMS) for indoor area (Main & Common plant) conforming to IP-52

45 Nos.

Total Ex-Works Price duly packed in INR/Total

Price.

Total Erection &

Commissioning Charges

in INR

ERECTION & COMMISSIONING

Unit Excise Duty @ on self

manufactured only

E & C (Rs)

QUANTITY

1 X 500 MW FGUTPP STAGE-IV - Price Schedule E & C for Public Address System

VAT/CST @ … in INR on

self manufacture

d only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Service tax @ including

cess on E & C in INR

Total E & C prices

including Service Tax

in INR

(B)

Unit Erection & Commissioning Charges in INR

ANNEXURE-11

10 Wall/column mounted, with handset, built-in power amplifier with horn type speaker 15W (RMS) for indoor area (CHP area) conforming to IP-65

25 Nos.

11 Sub-distribution frame (SDF) 24 pairs 35 Nos.

12 Portable handset station with multi-pin plug and 25 meter wire 4 Nos.

13 Socket box for Portable handset station 10 Nos.

14 Wall/ column mounted 4W Cone type loudspeaker 20 Nos.

15 Wall/ column mounted 15W Horn type loudspeaker (Main &common plant area) conforming to IP-55 for outdoor area

60 Nos.

16 Wall/ column mounted 15W Horn type loudspeaker (Main &common plant area) conforming to IP-52 for indoor area

45 Nos.

17 Wall/ column mounted 15W Horn type loudspeaker (CHPplant area) conforming to IP-65

75 Nos.

18 Power junction box 200 Nos.19 Signal junction box 30 Nos.20 Sound protecting floor mounted Acoustic hood 10 Nos.21 Weather protecting canopy for field call station 110 Nos.22 Power distribution box 2 Nos.

NOTES:12

345 Cables laying is not in the scope of the bidder (except the local cable from JB to station). However, termination of cables on

bidder's equipment is in bidder's scope.

The unit rates of E&C for all equipment are to be quoted by the bidder.Fabrication & painting of support structure for various equipment shall be in bidders scope. However, structural steel will be free issue from NBPPL.E & C spares required shall form part of erection & commissioning charges.Instruments required for testing & commissioning shall be arranged by the bidder.

ANNEXURE-11A

Item No. DESCRIPTION QUANTITY

Handsets(i) Handset with cord for outdoor station 15 nos(ii) Handset with cord for indoor station (desk for mounted) 4 nos(iii) Handset with cord indoor flush mounted 1 nos(iv) Portable Handset 1 nos

Loudspeakers(i) Outdoor horn type loudspeaker 15 nos(ii) indoor cone type loudspeaker 4 nos(iii) Cradle switch 2 nos of each type(iv) Push buttons of all types and model 2 nos. of each type

(v)Amplifier PCB with all components mounted for wall mounted Handset station 10%

(vi) Extension Amplifier PCB with all components mounted for wall type mounted Handset station (in case different from ix above) 2 nos. of each type

(vii) JB's of Handset. 2 nos(viii) JB's of Loudspeaker 2 nosix) Electronic modules of all types. 10% 10%

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices including Service Tax in

INR

Total Supply and E&C in INR

1 X 500 MW FGUTPP STAGE-IV - Price Schedule Mandatory Spares for Public Address System PUBLIC ADDRESS SYSTEM MANDATORY SPARES

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in

INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self

manufactured only

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

13. DRY TYPE TRANSFORMERS

A. MAIN ITEM

S.No Description Unit Qty Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax

in INR

Total Supply and E&C in INR

I3.3/0.433KV Indoor Transformer

(Dry Type)

12.0 MVA,3.3/0.433KV Indoor

Transformers (Dry Type)Nos 4

II Mandatory Spares

1For above 3.3/0.433KV 2.0 MVA

Transformer

1.1 HV Bushing Nos 1

1.2 LV Bushing Nos 1

1.3 LV Neutral Nos 1

1.4Complete Winding Limb (HV and

LV)Nos 1

1.5 WTI Nos 1

1.6Set of Thermistor / RTD with

associated leads complete for one transformer

Nos 1

Annexure-12 (Price Schedule/BOM ofDry Type Transformer)

Bill of quantity of Erection and commissioning of Dry Type Transformers A. MAIN ITEM

S.No Description Unit QtyUnit Erection &

Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty including cess @ ……Rs

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges in

INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in INR

12.0 MVA,3.3/0.433 kV Indoor 

Transformers (Dry Type)Nos 4

Annexure 12

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

14. OIL FILLED TRANSFORMERS

TOTAL

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E

& C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

(Nos) Rs. Rs.1 12500kVA, 11kV/3.5kV, 3 phase, 2

winding, outdoor, ONAN, Z= 11.7%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

2 2000KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 10.0%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

13

3 1600KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 8.0%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

4 1000KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 6.0%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

5 630KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 6.0%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

NOTES

S. NO. DESCRIPTION QTY. OF TRANSFORMERS

COST OF 10% EXTRA OIL PER TRANSFORMER

TOTAL COST OF 10% EXTRA OIL Total Ex-Works Price

duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E

& C in INR

Total E & C prices including Service

Tax in INR

Total Supply and

E&C Rs

10 % EXTRA TRANSFORMER OIL IN SEALED NON RETURNABLE STANDARD DRUMS FOR :

2

Annexure-13AAUXILIARY SERVICE TRANSFORMERS (OIL FILLED)

SCHEDULE OF PRICES – TRANSFORMERS

1. ALL ROUTINE AND ACCEPTANCE TESTS AS PER CLAUSE NO. 10.04 AND 10.05 OF TECHNICAL SPECIFICATION NO. PE-RC-999-302-E001 SHALL BE CARRIED OUT ON ALL TRANSFORMERS WITHOUT ANY ADDITIONAL COST. CHARGES FOR ALL ROUTINE AND ACCEPTANCE TESTS SHALL BE DEEMED TO BE INCLUDED IN BID PRICE. BIDDERS SHALL QUOTE ACCORDINGLY.

Annexure-13B

S. No. DESCRIPTION

AUXILIARY SERVICE TRANSFORMERS (OIL FILLED) SCHEDULE OF PRICES – EXTRA OIL

1

(A)       12500kVA, 11kV/3.5kV, 3 phase, 2 winding, outdoor, ONAN, Z= 11.7%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination))

13

(B)       2000KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 10.0%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination) )

2

(C)      1600KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 8.0%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

(D)      1000KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 6.0%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

(E)       630KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 6.0%, Dyn11, OFF Circuit taps ±5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

Note:Bidder shall supply 10% extra oil as per the quoted price. Quantity of extra oil shall be subject to approval during detail engineering.

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E

& C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

Rs. Rs.HV bushing with metal parts & gaskets

a)   11.0/3.5kV,125000KVA 1 no.b)   3.3/0.433kV, 2000KVA 1 no.c)   3.3/0.433kV, 1600KVA 1 no.d)   3.3/0.433kV, 1000KVA 1 noe)   3.3/0.433kV, 630KVA 1 no.

LV bushing with metal parts & gasketsa)       11.0/3.5kV,125000KVA 1 no.b)       3.3/0.433kV, 2000KVA 1 no.c)       3.3/0.433kV, 1600KVA 1 no.d)       3.3/0.433kV, 1000KVA 1 no.e)       3.3/0.433kV, 630KVA 1 no.

Neutral bushing with metal parts & gaskets

a) 11.0/3.5kV,125000KVA 1 no.c) 3.3/0.433kV, 2000KVA 1 no.d) 3.3/0.433kV, 1600KVA 1 no.e) 3.3/0.433kV, 1000KVA 1 no.f) 3.3/0.433kV, 630KVA 1 no.

4 WTI with contacts 1 no.5 OTI with contacts 1 no.

2

3

Annexure-13DAUXILIARY SERVICE TRANSFORMERS (OIL FILLED)

1

S. NO. DESCRIPTION QTY.SCHEDULE OF PRICES – MANDATORY SPARES

6 Pressure relief device 1 no.7 Magnetic oil gauge 1 no.8 Buchholz relay complete 1 no.9 Set of gaskets 1 set

10 Set of valves 1 set11 Air cell for conservator (if applicable) 1 no.

NOTES

SET CONSISTS OF QUANTITIES REQUIRED FOR 1 COMPLETE TRANSFORMER. WHEREVER ‘SET’ IS INDICATED ABOVE, IT MEANS THE TOTAL PARTS / ACCESSORIES REQUIRED TO REPLACE THE PARTICULAR ITEM FOR A GIVEN EQUIPMENT.

TOTALUnit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges in INR

Service tax @ including cess on E

& C in INR

Total E & C prices including Service Tax

in INR

(Nos) Rs. Rs.

3 1600KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 8.0%, Dyn11, OFF Circuit taps 5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

4 1000KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 6.0%, Dyn11, OFF Circuit taps 5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

5 630KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 6.0%, Dyn11, OFF Circuit taps 5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

Annexure‐13AUXILIARY SERVICE TRANSFORMERS (OIL FILLED)

BILL OF QUANTITY ERECTION & COMMISSIONING OF OIL FILLED SERVICE TRANSFORMERSS. No. DESCRIPTION

1 12500kVA, 11kV/3.5kV, 3 phase, 2 winding, outdoor, ONAN, Z= 11.7%, Dyn11, OFF Circuit taps 5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

2

2 2000KVA, 3.3kV/433V, 3 phase, 2 winding, outdoor, ONAN, Z= 10.0%, Dyn11, OFF Circuit taps 5% in steps of 2.5% (with cable box type HV and with bus-duct type LV termination)

13

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

15. EMERGENCY DG SET

ANNEXURE-14

S.NO. ITEM DESCRIPTION UNIT Nos.

Unit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges

INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in

INR

Total Supply and E&C in INR

1

1500 KVA, 3 phase, 415 V diesel generator set (The complete DG set shall be supplied along with equipments/accessories/panels/tools & tackales mentioned in various sections of the technical specification.)

Set 2

UNPRICED PRICE SCHEDULE OF SUPPLY FOR EMERGENCY DG SET

S.NO. ITEM DESCRIPTION UNIT Nos.

Unit Erection &

Commissioning Charges

in INR

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufacture

d only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges

in INR

Service tax @ including

cess on E & C in INR

Total E & C prices

including Service Tax

in INR

1

1500 KVA, 3 phase, 415 V diesel generator set (Erection/commisioning of the complete DG set along with equipments/accessories/panels/tools & tackales mentioned in various sections of the technical specification.)

Set 2

UNPRICED PRICE SCHEDULE OF E & C FOR EMERGENCY DG SETANNEXURE‐14

LIST OF MANDATORY SPARES FOR DG SET

GROUP-A

S.no. Item Description Quantity Unit Ex-works

price/Unit Price

Total Ex-Works Price

duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection &

Commissioning Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices

including Service Tax in

INR

Total Supply and E&C in

INR

None GROUP-B

S.no. Item Description Quantity

1 Ammeter 96x96mm, (0-200 amp) Accuracy class:1.0 1 No.

2 A.C. Voltmeter 96x96 mm, (0-15 kV) Accuracy class:1.0 1 No.

GROUP-C S.no. Item Description Quantity 1. Gaskets & packing 1 Set 2. Valve springs 1 Set 3. Fuel pump complete 1 Set 4. Fuel nozzles and needles 1 Set 5. Piston, complete with rings and rod 1 Set 6. Piston rings( for each engine) 1 Set

7. Flow and temperature relay of each type used 1 Set

8. Main and end bearing shells for the diesel engine 1 Set

9. Generator bearing sheets 1 No. 10. Rotor pole coil 1 No. 11 Battery charging rectifier diodes 4 Nos.

12 Complete rotating rectifier assembly for alternator 1 Set

13 Fuses for the excitation diodes 3 Sets 14 Automatic voltage regulator 1 Set

15 Solenoid coil for each solenoid operated valve or relay used 2 Each

16 Instrument and indicator of each type used 1 Each

17 Alarm and signal lamps of each type used 10% of total population

18 Cabinet lighting lamps( if applicable) 2 Each 19 Bearing check kit 1 Set 20 Shut down coil 1 No. 21 Lub oil pressure relay 1 No. 22 Filter screen 1 No. 23 ‘O’ ring injector 1 Set 24 ‘ O’ ring breather 1 Set 25 Magnetic pick up 1 No. 26 Actuator 1 Set 27 Air cleaner 1 Set 28 Belts( Fan belt) 1 Set 29 Hose bypass 1 No. 30 Hose turbo oil supply 2 Nos. 31 Hose turbo oil drain 2 Nos. 32 Turbo repair kit 1 No.

33 Over speed stop No. 34 Resistor for diesel generator 48 Nos.

35 Element lube oil filter for Diesel Engine 48 Nos.

36 Element lube oil by-pass filter for Diesel Engine 24 Nos.

37 Element fuel filter for Diesel Engine 24 Nos.

38 Plate corr. Resistor for Diesel Engine 96 Nos.

39 Element air cleaner for Diesel engine 4 Nos. 40 Diodes forward for alternator 3 Nos. 41 Diodes reverse for alternator 3 Nos. 42 HRC fuses links of various rating 3 Nos. of each type 43 Ammeter selector switches 1 No. 44 Local/Remote selector switches 1 No. 45 Voltmeter selector switches 1 No.

46 Push button for trip circuit healthy test 1 No.

47 White indication lamps for spring charged position 1 No.

48 Alarm bell 1 No.

49 Space heater along with control switch 1 No. 50 Trip circuit supervision relay 1 No.

51 Lube oil pump assembly/rotating assembly/impeller/shaft 1 Set

52 Starting air motor 1 No. 53 Governing mechanism of DG set 1 No.

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

16. EPABX SYSTEM

EPBAX SYSTEM Price Schedule

Main item

S NO DESCRIPTION UNIT

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in

INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices including Service Tax in

INR

Total Supply and E&C in INR

1Complete EPBAX system as per scope of supply mentioned in the Technical specification including installation & commisioning

1 LOT

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

17. ELECTRICAL EQUIPMENT HANDLING ARRANGEMENT

Project: 1X500 MW FGUTPPPackage: ELECTRIC HOIST and CHAIN PULLEY BLOCK - SUPPLYPrice Format

S.N. Description of equipment / item Total Qty requird

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

1 2 3 4 51.0 Total lumpsum firm price (ex-works) for design, engineering,

manufacturing, inspection and testing,painting, supply/delivery duly packed at project site including freight in line with drawings/ documents/ test procedures approved by NBPPL/NTPC for the total scope of electric hoists and chain pulley block defined as per technical specification PE-TS-404-xxx-xxx taking into account all clarifications, confirmations and agreements till date.

LOT

BREAK UP FOR PRICE AT 1.0

1.1 Total lumpsum price (ex-works) of 1 No.s Electric Hoist of 5T cap for ESP control room with all accessories including isolating switch, dsl, maintenance tools and tackles, E&C spares etc.

1 no.

1.2 Total lumpsum price (ex-works) of 1 No.s Electric Hoist of 3T cap for Boiler MCC room with all accessories including isolating switch, dsl, maintenance tools and tackles, E&C spares etc.

1 no.

1.3 Total lumpsum price (ex-works) of 1 No.s Manual Hoist (Chain pulley block) of 2T cap for MV switchgear with all accessories maintenance tools and tackles etc.

1 no.

1.4 Total lumpsum price (ex-works) for E&C spares as per annexure A 1 set

1.5 Total lumpsum price (ex-works) for maintenance tools and tackles as per annexure B

2 set

NOTE1

2

3

Bidder to note that total price indicated above at 1.0 shall be considered for evaluation and hence should be complete in all respect for the full scope defined and considering all terms and conditions agreed.

Bidder to note that in their un-price bid, you must indicate as "QUOTED" against unit price & total price column. Price should be indicated in Price Bid only.

Any item not included in the price quoted above and shown separately will not be taken cognizance of and the offer shall be liable for rejection.

Project: 1X500 MW FGUTPPSYSTEM- ANNEXURE-APackage: ELECTRIC HOIST and CHAIN PULLEY BLOCKPrice Format

Sl.no Description Total quantity required

Unit

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax

in INR

Total Supply and E&C in INR

1 2 3 4 5 6A for 3T capacity electric hoist.

1 sets

I) Overload Relay

ii) Limit Switch

iii) Fuse Link

B for 5T capacity electric hoist.1 Sets

I) Overload Relay

ii) Limit Switch

iii) Fuse Link

Total for site price for Comm. Spares

List of Commisioning spares

Project: 1X500 MW FGUTPPSYSTEM- ANNEXURE-BPackage: ELECTRIC HOIST and CHAIN PULLEY BLOCKPrice Format

Sl.no Description Total quantity required

Unit

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax

in INR

Total Supply and E&C in INR

1 Complete set of 6 nos. ringspanners(Indicate sizes) 1

Sets

2 Complete set of screwdrivers (Min 6 nos , indicate size) 1

Sets

3 Adjustable Spanner 12" 1 no.

4 Line tester 1 no.5 Insulated plier 1 no.6 Grease gun 1 no.7 Oil gun 1 no.8 Tool box 1 Sets

Total Price

Note: 1 LOT of all items indicated above are to be provided for electric hoist and chain pulley block i.e. 1 LOT for electric hoist and 1 LOT for chain pulley block

List of Maintenance Tools & Tackles

Project: 1X500 MW FGUTPPSYSTEM- Package: ELECTRIC HOIST and CHAIN PULLEY BLOCK - E & CPrice Format

S.N. Description of equipment / item Total Qty requird

Unit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in

INR/Total Price.

Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges in INR

Service tax @ including cess on E

& C in INR

Total E & C prices including Service

Tax in INR

1 2 3 4 51.0 Total lumpsum firm price ex-works for receipt, unloading, storage

& handling at site, erection and commissioning, load testing, trial run, handling over to customer for the total scope of electric hoists and chain pulley block defined as per technical specification PE-TS-404-xxx-xxx taking into account all clarifications, confirmations and agreements till date.

LOT

BREAK UP FOR PRICE AT 1.01.1 Total lumpsum price (ex-works) of 1 No.s Electric Hoist of 5T

cap for ESP control room with all accessories including isolating switch, dsl, maintenance tools and tackles, E&C spares etc.

1 no.

1.2 Total lumpsum price (ex-works) of 1 No.s Electric Hoist of 3T cap for Boiler MCC room with all accessories including isolating switch, dsl, maintenance tools and tackles, E&C spares etc.

1 no.

1.3 Total lumpsum price (ex-works) of 1 No.s Manual Hoist (Chain pulley block) of 2T cap for MV switchgear with all accessories maintenance tools and tackles etc.

1 no.

NOTE1

23

Bidder to note that total price indicated above at 1.0 shall be considered for evaluation and hence should be complete in all respect for the full scope defined and considering all terms and conditions agreed.

Any item not included in the price quoted above and shown separately will not be taken cognizance of and the offer shall be liable for rejection.Bidder to note that in their un-price bid, you must indicate as "QUOTED" against unit price & total price column. Price should be indicated in Price Bid only.

1X500 MW UNCHAHAR TPP, RAE BARELI Price Schedule – Volume II, Part C

Tech Spec No.- PE-TS-401-999-E001; Rev.0

OPTIONAL ITEMS

Board  11kV  Switchboard

Rating 3150A

S.no Feeder Description Rating Module Type Quantity (Nos.) Unit Price (Rs.)

1 Incomer  3150A DC 1

2 Tie from Other Switchboard 2750A DE 1

Board  11kV  Switchboard

Rating 2750A

S.no Feeder Description Rating Module Type Quantity (Nos.) Unit Price (Rs.)

1 Incomer  2750A DC 1

2 Tie from Other Switchboard 2750A DE 1

1X500 MW FGUTPP

Annexure ‐2J ( Board Wise BOM & Schedule of Unit Prices for 11kV  switchboard )

(OPTIONAL ITEM)

 1X500 MW UCHAHAR FGTPS (UNIT‐6) RECOMMENNDED O SPARES FOR LV SWITCHGEAR,LT BUS DUCT   AND  NGR (OPTIONAL)   ANNEXURE‐3A

RATING(A) BOARD NO.

56RECOMMENDED O & M 

SPARES for LV switchgearNOS. 1 BIDDER TO FURNISH

Unit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufactured

only

Total Supply and E&C in

INRSr.No. ITEM NAME UOM TOTAL QTY.REMARKS

Freight including Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges INR

Service tax @ including cess on E &

C in INR

Total E & C prices

including Service Tax

in INR

PAGE 1 OF 4

123
Text Box

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

1 INCOMING FEEDER UNIT

a) Incoming ACB to PCC/PMCC from Trafo. - Module Type DAET (I/C)

1000A1250A1600A2500A3200A

b) Incoming ACB to MCC - Module Type DAE (I/C)630A800A1000A1250A1600A

c) Incoming ACB to Emergency MCC - Module Type DAE(EMG-I/C)800A1000A1250A

d) MCCB Incomer for MCC / ACDB – Module Type E3 (I/C) (Upto 200A SFU controlled)Upto 63A – Fixed Type125A – Fixed Type200A – Fixed Type250A – Fixed Type400A – Fixed Type

630A – Fixed Type

Upto 63A – Drawout Type (Upto 200A SFU controlled)

125A – Drawout Type

200A – Drawout Type250A – Drawout Type400A – Drawout Type630A – Drawout Type

e) TPN SFU Incomer for AC Fuse DBs – Module Type H3 (I/C)63A 125A

f) 220V DCDB Incomer from charger - Module type CH 200A – CH Fixed Type

400A – CH Fixed Type630A – CH Fixed Type800A – CH Fixed Type200A – CH Drawout Type400A – CH Drawout Type630A – CH Drawout Type800A – CH Drawout Type

g) 220V DCDB Incomer from battery - Module type DB200A – DB Fixed Type

400A – DB Fixed Type630A – DB Fixed Type800A – DB Fixed Type200A – DB Drawout Type400A – DB Drawout Type630A – DB Drawout Type800A – DB Drawout Type

h) 220V DC Fuse DB Incomer from DCDB - Module type HD32A 50A 63A

2 BUSCOUPLER UNITa) ACB buscoupler for PCC/PMCC- Module Type DAE (TIE)

1000A1250A1600A2500A3200A

b) ACB buscoupler for PCC/PMCC- Module Type DAE (B/C)

630A800A1000A1250A1600A

c) MCCB buscoupler – Module type E3 (B/C) (Upto 200A SFU controlled)UPTO 63A - Fixed Type125A - Fixed Type

PAGE 1 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

200A - Fixed Type250A - Fixed Type

400A - Fixed Type

630A - Fixed Type

UPTO 63A - Drawout Type

125A - Drawout Type

200A - Drawout Type

250A - Drawout Type

400A - Drawout Type

630A - Drawout Type

3 Outgoing ACB supply feeder - Module Type DAE (O/G)630A800A1000A1250A1600A2000A

4 Outgoing ACB MLDB feeder - Module Type DAE (LDB)630A800A

5 Outgoing ACB motor feeder - Module Type DM/PM (controlled from DDCMIS/PLC)100.1 - 200KW

6 DOL Motor Starter - Unidirectional Drive - Drawout Type

a) Module Type K2 (Controlled from Local Control Panel)

Upto 5.5KW5.6 - 7.0KW7.1 - 13KW13.1 - 24KW24.1 - 29.9KW

b) Module Type K21 (Controlled from Local Control Panel)30.0 - 37.0KW37.1 - 40.0KW40.1 - 49.9KW50.0 - 55.0KW55.1 - 80KW80.1 - 90KW90.1 - 100KW

c) Module Type K3 (Controlled from Local Push Button Station)Upto 5.5KW5.6 - 7.0KW7.1 - 13KW13.1 - 24KW24.1 - 29.9KW

d) Module Type K31 (Controlled from Local Push Button Station)30.0 - 37.0KW37.1 - 40.0KW40.1 - 49.9KW50.0 - 55.0KW55.1 - 80KW80.1 - 90KW90.1 - 100KW

e) Module Type DK2/AK2/PK2 (Controlled from DDCMIS/ATRS/PLC)

Upto 5.5KW

5.6 - 7.0KW7.1 - 13KW

13.1 - 24KW24.1 – 29.9KW

f) Module Type DK21/AK21/PK21 (Controlled from DDCMIS/ATRS/PLC)

30.0 - 37.0KW37.1 - 40.0KW40.1 - 49.9KW50.0 - 55.0KW55.1 - 80KW80.1 - 90KW90.1 - 100KW

g) Module Type DKE2/AKE2/PKE2 (Controlled from DDCMIS/ATRS/PLC)

Upto 5.5KW

5.6 - 7.0KW

7.1 - 13KW

PAGE 2 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

13.1 - 24KW24.1 – 29.9KW

h) Module Type DKE21/AKE21/PKE21 (Controlled from DDCMIS/ATRS/PLC)30.0 - 37.0KW37.1 - 40.0KW40.1 - 49.9KW50.0 - 55.0KW55.1 - 80KW80.1 - 90KW90.1 - 100KW

7 RDOL Motor Starter – Bidirectional Drive Drawout Type

a) Module Type DN1/AN1/PN1 (Controlled from DDCMIS/ATRS/PLC)

Upto 5.5KW5.6 - 7.0KW

7.1 - 13KW

13.1 - 24KW

24.1 – 29.9KW

b) Module Type N1 (Controlled from Local Control Panel)Upto 5.5KW5.6-7.0KW7.1 - 13KW13.1 - 24KW24.1 – 29.9KW

8 Outgoing MCCB controlled feedersa) Outgoing MCCB controlled supply feeder - Module Type E3 (O/G) up

to 200A SFU controlled.

upto 10A - Fixed type16A - Fixed type25A - Fixed type32A - Fixed type63A - Fixed type80A - Fixed type100A - Fixed type125A - Fixed type160A - Fixed type200A - Fixed type250A - Fixed type400A - Fixed type630A - Fixed typeupto 10A - Drawout type (up to 200A SFU controlled)16A - Drawout type25A - Drawout type32A - Drawout type63A - Drawout type80A - Drawout type100A - Drawout type125A - Drawout type160A - Drawout type200A - Drawout type250A - Drawout type400A - Drawout type630A - Drawout type

b) Double pole MCCB controlled 1-ph feeder - E1 (O/G) - Fixed Type (up to 200A SFU controlled)16A25A32A63A125A

c) Double pole MCCB controlled 1-ph feeder - E1 (O/G) - Drawout Type (up to 200A SFU controlled)

16A25A32A63A125A

d) 3-Ph MCCB controlled Outgoing contactor feeder (EA3) – Fixed Type (up to 200A SFU controlled)

16A25A32A63A

PAGE 3 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

e) 3-Ph MCCB controlled Outgoing contactor feeder (EA3) – Drawout Type (up to 200A SFU controlled)16A

25A32A63A125A185A200A

f) 1-Ph MCCB controlled Outgoing contactor feeder (EA1) – Fixed Type (up to 200A SFU controlled)16A

25A32A63A125A

g) 1-Ph MCCB controlled Outgoing contactor feeder (EA1) – Drawout Type (up to 200A SFU controlled)16A25A32A63A125A

9 Outgoing Switch-fuse feeders

a) Outgoing TPN Switch-fuse feeder - Module Type H3 (O/G)

16A25A32A

b) Single phase switch-fuse feeder - H1 (O/G)

16A25A32A

c) 220V DC Outgoing switch fuse feeder (X)

6A

10A

16A25A32A50A63A100A125A160A200A400A630A

10 Common Auxiliary Modulea) PT module

i Bus PT module for PCC/PMCC-G1ii Bus PT module for Emergency MCC-G2iii Bus PT module for MCC-VMiv Bus PT module for DCDB-Sb) Panel space heating modulec) 110V AC control supply module – Type CS (consisting of 415/110V

control Trafo.)1KVA2KVA2.5KVA3KVA5KVA7.5KVA10KVA

d) 240 V AC control supply module – type CS (consisting of 415/240V control Trafo.)1KVA2KVA2.5KVA3KVA5KVA7.5KVA10KVA

e) 240V AC motor space heater module220V DC supply modulef)

PAGE 4 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

(for receiving 220V DC supply)g) 24 V winding heating moduleh) Alarm modulei) Test supply module

11 Empty Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar

a) MCC Panel (Double Front Drawout Type)250 / 250A400 / 400A630 / 630A800 / 630A800 / 800A1000 / 630A1000 / 800A1000 / 1000A1250 / 630A1250 / 800A1250 / 1000A1250 / 1250A1600 / 630A1600 / 800A1600 / 1000A1600 / 1250A1600 / 1600A

b) MCC Panel (Double Front Fixed Type)250 / 250A400 / 400A630 / 630A800 / 630A800 / 800A1000 / 630A1000 / 800A1000 / 1000A1250 / 630A1250 / 800A1250 / 1000A1250 / 1250A1600 / 630A1600 / 800A1600 / 1000A1600 / 1250A1600 / 1600A

c) 220V DCDB Panel (Double Front Fixed type) UPTO 800A (with 630A VBB)1000A (with 630A VBB)

d) 220V DCDB Panel (Double Front Drawout type) UPTO 800A (with 630A VBB)1000A (with 630A VBB)

12 Empty Panel With Horizontal & Vertical Busbar, Support & Auxiliary Busbar

a) PCC Panel (Single Front Drawout Type)1600 / 1600A2500 / 2500A3200 / 3200A

b) MCC Panel (Single Front Drawout Type)250 / 250A400 / 400A630 / 630A800 / 630A800 / 800A1000 / 630A1000 / 800A1000 / 1000A1250 / 630A1250 / 800A1250 / 1000A1250 / 1250A1600 / 630A1600 / 800A1600 / 1000A1600 / 1250A1600 / 1600A

c) MCC Panel (Single Front Fixed Type )

PAGE 5 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

250 / 250A400 / 400A630 / 630A800 / 630A800 / 800A1000 / 630A1000 / 800A1000 / 1000A1250 / 630A1250 / 800A1250 / 1000A1250 / 1250A1600 / 630A1600 / 800A1600 / 1000A1600 / 1250A1600 / 1600A

d)  DCDB Panel (Single Front Fixed Type Each Rating)UPTO 800A (with 630A VBB)1000A (with 630A VBB)

e)  DCDB Panel (Single Front Drawout Type Each Rating)UPTO 800A 1000A

13 ACB Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar800 / 630A 800 / 800A 1000 / 630A 1000 / 800A 1000 / 1000A 1250 / 630A1250 / 800A1250 / 1000A1250 / 1250A1600 / 630A1600 / 800A1600 / 1000A1600 / 1250A1600 / 1600A2500 / 630A2500 / 800A2500 / 1000A2500 / 1250A2500 / 1600A2500 / 2500A3200 / 630A3200 / 800A3200 / 1000A3200 / 1250A3200 / 1600A3200 / 2500A3200 / 3200A4000 / 630A4000 / 800A4000 / 1000A4000 / 1250A4000 / 1600A4000 / 2500A4000 / 3200A4000 / 4000A

14 Dummy Panel UPTO 630A800A1000A1250A1600A2500A3200A4000A

15 Unit Prices For Circuit Componentsa) Air Circuit Breaker without releases

630A (M)

PAGE 6 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

800A (M)1000A (M)1250A (M)630A800A1000A1250A1600A2500A3200A4000A

b) Air circuit breaker (with built-in O/L & S/C releases)630A (M)800A (M)1000A (M)1250A (M)630A800A1000A1250A1600A2500A3200A4000A

c) MCCB (Utilization category-'A')16A25A32A63A80A115A150A185A265A315A400A630A

d) MCCB (Utilization category-'B')16A25A32A63A80A115A150A185A265A315A400A630A

d (i) SFU16A25A32A63A80A115A150A185A265A315A400A630A

e) Switches (AC)-TPNUpto 16A25A32A63A125A250A400A630A

PAGE 7 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

f) Switches (DC)Upto 16A25A40A60A100A200A300A400A630A

g) HRC Fuse Links (Offset tag Type)Upto 10A16A25A32A50A63A

h) DIN Type (Blade Contact)Upto 10A16A20A32A36A50A63A80A100A125A160A200A250A315A400AControl Fuse Link

i) Power contactor (AC)16A25A32A63A80A115A185A265A315A400A630A

j) Power contactor (DC)16A25A32A63A80A115A150A185A265A400A

k) Fuse Base UPTO 20A32A50/63A100A250A400A630A

l) Auxiliary contactor AC/DCi) AC Aux. contactor

2NO + 2NC3NO + 3NC4NO + 4NC6NO + 6NC

ii) DC Aux. contactor

PAGE 8 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

2NO + 2NC3NO + 3NC4NO + 4NC6NO + 6NC

m) Protection RelayVAGM 23CTU 12CTU 32VTT 11VAG 11VAA 11VAJHM 13VAJHM 23CDGM-12CAG 12CAG 34CCUM 21CDG11CDG 31CDG61VDG 14CDV 62CAG 14VAX 31CAG 37CAEM-21VAG-21VAJC-11CTMM-501MOTPROVAA21VTT12VTIGVTU21NUMERICAL RELAY FOR FOLLOWING FUNCTIONS:• SHORT CIRCUIT PROTECTION (51)• EARTH FAULT PROTECTION (51N)• UNDER VOLTAGE PROTECTION (27)• TRIP CIRCUIT SUPERVISION (95)NUMERICAL RELAY FOR FOLLOWING FUNCTIONS:• SHORT CIRCUIT PROTECTION (51)• EARTH FAULT PROTECTION (51N)• TRIP CIRCUIT SUPERVISION (95)Numerical relay for E/F protection for DCDBNumerical Check synchronising RealyNUMERICAL COMPOSITE RELAY for STANDBY E/F,SHORT CIRCUITPROTECTION, E/F PROTECTION, OVER LOAD PROTECTION,RESTRICTED E/F PROTECTION TC SUPERVISION,CB FAILURE PROTECTION,SYNCHRONISING CHECK FEATURE,MASTER TRIP FEATURE,CB MONITERING, UNDER VOLTAGE PROTECTIONWITH METERING OF CURRENT(3 PHASE), VOLTAGE (ALL3 PHASE & PHASE TO NEUTRAL) kW, ACTIVE POWER ,REACTIVE POWER,ENERGY, NEUTRAL CURRENT/RESIDUAL VOLTAGE, (WITH COMMUNICATION USING 61850 PROTOCOL)Check synchronising Realy Type-SKE

n) O/L Relaysi) Thermal O/L relay with SPP

Upto 5.5KW5.6 to 11KW11.1 to 22KW22.1 to 45KW45.1 to 75MW75.1 to 100KW

ii) Heavy Duty Thermal O/L relay with SPPUpto 5.5KW5.6 to 11KW11.1 to 22KW22.1 to 45KW45.1 to 75MW75.1 to 100KW

o) Timer (each type)p) Meter of each type & range

AC ammeter (Digital)AC ammeter (Analog)DC ammeter (Digital)

PAGE 9 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

DC ammeter (Analog)AC voltmeter (Digital)DC voltmeter (Analog)Wattmeter (3 Phase)Wattmeter (1 Phase)3-PH Electronic KWH Meter with RS485 Port1-PH Electronic KWH Meter with RS485 PortFrequency meter

q) Single Phase Preventor Relayr) MCB (each applicable type & rating)s) Control & Selector Switch And Push Button Stationi) Breaker control switchii) Test/normal/trial selector switchiii) Auto/manual switchiv) Limit switchv) Ammeter selector switchvi) Voltmeter selector switchvii) Synchronisation selector switchviii) Push Button

2NO + 2NC Shrouded1NO + 1NC Shrouded2NO + 2NC Mushroom head stayput2NO + 2NC Lockable type

t) Indicating Lamp Assembly (LED Type)u) CTi) Metering CT

Upto 75/1A100/1A125/1A150/1A200/1A250/1A300/1A400/1A500/1A630/1A800/1A1000/1A1250/1A1600/1A2000/1A2500/1A3200/1A4000/1A

ii) Protection CT (5P20)Upto 75/1A100/1A125/1A150/1A200/1A250/1A300/1A400/1A500/1A630/1A800/1A1000/1A1250/1A1600/1A2000/1A2500/1A3200/1A4000/1A630/5A800/5A1000/5A1250/5A1600/5A2000/5A2500/5A3200/5A

iii) PS Class CT

PAGE 10 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

1600/1A2500/1A3200/1A4000/1A2500/5A3200/5A4000/5A

v) Voltage Transformeri) 415/√3 : 110/√3V, 1ph, 50VAii) 415/√3 : 110/√3V, 1ph, 100VAiii) 415/√3 : 240/√3V, 1ph, 50VAiv) 415/√3 : 240/√3V, 1ph, 100VAw) Toggle switch

16A toggle switchx) Secondary Isolating Contact Blocky) Control Terminal (Fixed)z) Thermostat

aa) 4-20mA Dual Output Current transducerab) 4-20mA Dual Output Voltage transducerac) 4-20mA Dual Output Watt transducerad) 4-20mA Dual Output Frequency transducerae) Interposing relay RE 302 or Eqvt with freewheeling diode & LEDaf) 4-16-20mA Dual Output Current transducerag) 4-16-20mA Dual Output Voltage transducerah) 4-16-20mA Dual Output Watt transducerai) 4-16-20mA Dual Output Frequency transducer16 Foundation Framea) MCC panel

upto 1600A (SF)2500A (SF)3200A (SF)4000A (SF)upto 1600A (DF)2500A (DF)3200A (DF)4000A (DF)

b) 220V DCDB panelSFDF

c) PCC / PMCC panelupto 1600A2500A3200A4000A

17 ACDB i) 12 way with 1-Ph O/G feedersii) 12 way with TPN O/G feedersiii) 20 way with TPN O/G feeders18 LT Busduct & Accessoriesa) Straight run per meter, TPN

1600A2500A3200A

b) 90 Deg. Bend (extra over & above straight run)1600A2500A3200A

c) Termination flexible -TPN set (extra over & above straight run)Copper1600A2500A3200AAluminium1600A2500A3200A

d) Adapter, TPN for equipment terminal connection1600A2500A3200A

e) Phase cross over chamber 1600A

PAGE 11 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

2500A3200A

f) Busduct Supporting Structure per Tong) Expansion joint, TPN in the run of Busduct (extra over & above

straight run)1600A2500A3200A

19 Connection from PMCC/MCC panel to PMCC/MCC panel250A400A630A800A1000A1250A1600A2500A3200A

20 Cable Glands & Lugs: a) Single Compression Cable Glands for cable sizes:

2C X 2.5 Sq. mm. 3C X 2.5 Sq. mm. 5C X 2.5 Sq. mm. 7C X 2.5 Sq. mm. 12C X 2.5 Sq. mm. 16C X 2.5 Sq. mm. 2C X 10 Sq. mm. 2C X 16 Sq. mm. 2C X 25 Sq. mm. 2C X 35 Sq. mm. 3C X 2.5 Sq. mm. 3C X 10 Sq. mm. 3C X 16 Sq. mm. 3C X 25 Sq. mm. 3C X 35 Sq. mm. 3C X 50 Sq. mm. 3C X 70 Sq. mm. 3C X 95 Sq. mm. 3C X 150 Sq. mm. 3C X 185 Sq. mm. 3C X 240 Sq. mm. 3.5C X 300 Sq. mm. 3.5C X 240 Sq. mm. 3.5C X 185 Sq. mm. 3.5C X 95 Sq. mm. 4C X 16 Sq. mm. 4C X 35 Sq. mm. 1C X 35 Sq. mm.1C X 500 Sq. mm. 1C X 630 Sq. mm.

b) Double Compression Cable Glands for cable sizes:2C X 2.5 Sq. mm. 3C X 2.5 Sq. mm. 5C X 2.5 Sq. mm. 7C X 2.5 Sq. mm. 12C X 2.5 Sq. mm. 16C X 2.5 Sq. mm. 2C X 10 Sq. mm. 2C X 16 Sq. mm. 2C X 25 Sq. mm. 2C X 35 Sq. mm. 3C X 2.5 Sq. mm. 3C X 10 Sq. mm. 3C X 16 Sq. mm. 3C X 25 Sq. mm. 3C X 35 Sq. mm. 3C X 50 Sq. mm. 3C X 70 Sq. mm. 3C X 95 Sq. mm. 3C X 150 Sq. mm. 3C X 185 Sq. mm. 3C X 240 Sq. mm.

PAGE 12 OF 13

1 X 500 MW FG TPS (STAGE-IV)

LV SWITCHGEAR LT BUSDUCT NGR(PE-TS-401-506-E001, REV.0)

SCHEDULE OF UNIT PRICES FOR ADDITION / DELETION (OPTIONAL)

ANNEXURE-3H

SL.NO. ITEM DESCRIPTION Unit Ex-works price

3.5C X 300 Sq. mm. 3.5C X 240 Sq. mm. 3.5C X 185 Sq. mm. 3.5C X 95 Sq. mm. 4C X 16 Sq. mm. 4C X 35 Sq. mm. 1C X 35 Sq. mm.1C X 500 Sq. mm. 1C X 630 Sq. mm.

c) Cable Lugs for sizes:2.5 Sq. mm. 10 Sq. mm. 16 Sq. mm. 25 Sq. mm. 35 Sq. mm. 50 Sq. mm. 70 Sq. mm. 95 Sq. mm. 150 Sq. mm. 185 Sq. mm. 240 Sq. mm. 300 Sq. mm. 500 Sq. mm. 630 Sq. mm.

d) FIBER OPTICAL CABLE (PER METER)21 Daily 8 hour rate deployed at site:

Engineer : (per day)22 Module Name plate23 Wires for Secondary wiring:a) 1.5 Sq. mm. per meterb) 2.5 Sq. mm. per meterc) 4.0 Sq. mm. per meter

24 Control Terminal for Secondary wiring suitable for cable size:

a) 0.5 Sq. mm. b) 1.5 Sq. mm. c) 2.5 Sq. mm.

25 Unit price for following tests:a) Local Push Button Station - Degree of protection testb) Local motor Starter - Degree of protection testc) Type tests on NGRi) Heat run test on prototypeii) DOP test for IP 33iii) DOP test for IP 55c) Any other test as per IS / BHEL specification

26 LPBS TYPE-ALPBS TYPE-BLPBS TYPE-C

27 LOCAL MOTOR STARTERLOCAL MOTOR STARTERS 0.37 KWLOCAL MOTOR STARTERS 0.55 KWLOCAL MOTOR STARTERS 0.75 KWLOCAL MOTOR STARTERS 1.10 KWLOCAL MOTOR STARTERS 1.50 KWLOCAL MOTOR STARTERS 2.20 KWLOCAL MOTOR STARTERS 3.70 KWLOCAL MOTOR STARTERS 5.5 KW

28 ANY OTHER ITEM WHICH MAY BE REQUIRED FOR ADDITION / DELETION DURING DETAILED ENGINEERING

PAGE 13 OF 13

1x 500MW FGUTPP STAGE IV

PRICE SCHEDULE FOR CABLING, EARTHING LIGHTNING PROTECTION SYSTEMS (SUPPLY)

Item.No Item Type TestTest Charges

(in Rs.)

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in INR

Total Supply and E&C in INR

1 TREFOIL CLAMPS Short Circuit Test (for fault levels and durations specified in the specification)

2 HT TERMINATION KITS Type Tests as per IS:13573 for 11 KV kitsType Tests as per IS:13573 for 3.3 KV kitsType Tests as per VDE 0278 for 3.3 KV kits

3 STRAIGHT THROUGH JOINTING KITS Type Tests as per IS:13573 for 11 KV kitsType Tests as per IS:13573 for 3.3 KV kitsType Tests as per VDE 0278 for 3.3 KV kits

4 JUNCTION BOXImpact resistance for impact energy of 2 Joules (IK07)as per BS EN50102Thermal ageing at 70deg C for 96 hours as per IEC60068-2-2Bb.Class of protection ( IP 55)HV test.

ANNEXURE-4B: TYPE TEST CHARGES (OPTIONAL)

A TYPE TEST FOR TYPE-A FIRE SEALING SYSTEM(OPTIONAL)TYPE TEST UNIT Unit Price in INR Total Price in INR Excise Duty @ on self

manufactured onlyVAT/CST @ … in INR on self manufactured

only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges INR

Service tax @ including cess on Total Price in INR

Total Price including Service Tax

in INR

1Accelerated Ageing Test

LOT

2Water Absorption Test

LOT

3 Fire Rating Test LOT4 Hose Stream Test LOT5

Vibration Test Followed by Fire rating TestLOT

B TYPE TEST FOR TYPE-B FIRE SEALING SYSTEM(OPTIONAL)TYPE TEST UNIT Unit Price in INR Total Price in INR Excise Duty @ on self

manufactured onlyVAT/CST @ … in INR on self manufactured

only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges INR

Service tax @ including cess on Total Price in INR

Total Price including Service Tax in INR

1 Accelerated Ageing Test LOT

2 Water Absorption Test LOT

3 Fire Rating Test LOT

4 Hose Stream Test LOT

5Vibration Test Followed by Fire rating Test

LOT

Notes:‐

1 For Type Tests refer clause no. 6.0 of Section‐C of Part ‐B of specification

FEROZ GANDHI UNCHAHAR TPPSTAGE-IV( 1 X 500MW)

ANNEXURE- 5B

PRICE SCHEDULE FOR TYPE TEST OF FIRE SEALING SYSTEM (OPTIONAL)

s.no. CIVIL WORKS(OPTIONAL)

DESCRIPTION UNIT Unit Price in INR Excise Duty @ on self manufactured

only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges INR

Service tax @ including cess on Unit Price in INR

Unit Price including Service

Tax in INR

a ENLARGEMENT OF PENETRATION AREA IN

SQM

a1 BRICK WALL SQMa2 CONCRETE WALL SQMa3 FLOORS SQMb REDUCTION OF PENETRATION

AREA INb1 BRICK WALL SQMb2 CONCRETE WALL SQMb3 FLOORS SQM

Notes-

1Unit rates for civil works shall be as per clause no. 8.3 (e) of Section-D of Part-B of specification.

FEROZ GANDHI UNCHAHAR TPPSTAGE-IV( 1 X 500MW)

ANNEXURE- 5B

PRICE SCHEDULE FOR CIVIL WORKS OF FIRE SEALING SYSTEM (OPTIONAL)

Sr. No. Item code Item Description Unit Quantity Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on

self manufactur

ed only

VAT/CST @ … in INR on

self manufactur

ed only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection & Commissio

ning Charges

INR

Service tax @ including cess on E & C in INR

Total E & C prices

including Service Tax

in INR

Total Supply and E&C in INR

(B) OPTIONAL ITEMS1.0

O & M SPARES FOR 220V BATTERY(BIDDER TOFURNISH THE LIST)

LOT 1

2.0

INCREMENTAL INCREASE/DECREASE IN BATTERY RATING*

*Unit rate of additional price applicable for battery charger capacity increase/decrease by 10AH

NOS 1

3.0SUPERVISION CHARGES OF COMMISSIONING OF220V DC BATTERY)

LOT 1

4.0SUPERVISION CHARGES OF ERECTION &COMMISSIONING OF 220V DC BATTERY) SET 1

5.0 SUPV. OF E & C- MANDAY RATE SET 1

6.0 SUPV. OF E & C- TRAVEL CHARGE SET 1

7.0 TYPE TEST

a DISCHARGE PERFORMANCE AT LOW TEMPERETURE LOT 1

b LIFE CYCLE TEST LOT 1

c AIR PRESSURE TEST LOT 1

d VARIFICATION OF CONSTRUCTIONAL REQUIREMENT LOT 1

e ENVIRONMENTAL TEST LOT 1

f INSUALATION RESISTANCE TEST LOT 1

Note: Cable Lugs at Battery terminals shall be in bidders Scope & Same shall be informed during detailed engineering.

FEROZ GANDHI UNCHAHAR TPP STAGE-IV( 1 X 500MW) ANNEXURE-9BBOQ-cum-PRICE SCHEDULE FOR 220V DC BATTERY (NI-CD Battery)

Page 1 of 1

Sr. No. Item code Item Description Unit Quantity Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR (6+7+8+9)

Total Erection & Commissioning Charges INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax (11+12) in INR

Total Supply and E&C in INR

(B) OPTIONAL ITEMS1.0

O & M SPARES FOR 220V BATTERY(BIDDER TOFURNISH THE LIST) LOT 1

2.0

INCREMENTAL INCREASE/DECREASE IN BATTERY RATING*

*Unit rate of additional price applicable for battery charger capacity increase/decrease by 10AH

NOS 1

3.0 SUPERVISION CHARGES OF COMMISSIONING OF220V DC BATTERY)

LOT 1

4.0SUPERVISION CHARGES OF ERECTION &COMMISSIONING OF 220V DC BATTERY) SET 1

5.0 SUPV. OF E & C- MANDAY RATE SET 1

6.0 SUPV. OF E & C- TRAVEL CHARGE SET 1

7.0 TYPE TEST

aTEST FOR CAPACITY- TEST FOR VOLTAGE DURING DISCHJARGE

LOT 1

d TEST FOR CHARGE RETENTION/ LOSS OF CAPACITY LOT 1

c AMPERE HOUR AND WATT-HOUR EFFICIENCY TEST LOT 1

d ENDURANCE TEST. LOT 1

Note: Cable Lugs at Battery terminals shall be in bidders Scope & Same shall be informed during detailed engineering.

FEROZ GANDHI UNCHAHAR TPP STAGE-IV( 1 X 500MW) ANNEXURE-9BBOQ-cum-PRICE SCHEDULE FOR 220V DC BATTERY (LEAD -ACID PLANTE)

Page 1 of 1

SL. NO. DESCRIPTION QUANTITY Unit Price in

INR Total Price in INR

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess

on Total Price in INR

Total Price including Service

Tax in INR

1Rated dielectric strength tests

1LOT

(i)Rated low frequency withstand voltage dry test

(ii)Rated full wave impulse withstand voltage test.

2

Short circuit rating and transient recovery voltage tests

1LOT

(i)

Test for rated symmetrical short circuit current interrupting capability, duty cycle and rated transient recovery voltage parameters

(ii)

Test for rated closing, latching and short time current carrying capability

(iii)

Test for rated Generator source asymmetrical short circuit interrupting capability.

3Load current switching test.

1LOT

4Out of phase switching current tests.

1LOT

5Rated excitation current switching tests.

1LOT

6

Type tests and oscillographic test records for closing and tripping timings for generator circuit breaker of the rating offered.

1LOT

NOTE:(1) Bidder to indicate type test charges separately for each test.

ANNEXURE –IPRICE SCHEDULE FOR TYPE TEST - GCB

123
Text Box
GCB

FEROZ GANDHI UNCHAHAR TPP STAGE-IV( 1 X 500MW) ANNEXURE 9C

Sr. No. Item Description Unit QuantityRemarks

Unit Ex-works

price/Unit Price

Total Ex-Works Price duly packed

in INR/Total Price.

Excise Duty @ on

self manufactur

ed only

VAT/CST @ … in INR on self

manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply and E&C in INR

OPTIONAL ITEMS

1INCREMENTAL INCREASE/DECREASE IN CHARGER RATING*

NOS 1*Unit rate of additional price applicable for battery charger capacity increase/decrease by 20A

2INCREMENTAL INCREASE/ DECREASE IN DISCH RESISTOR RATING*

NOS 1*Unit rate of additional price applicable for discharge resistor capacity increase/decrease by 20A

3SUPERVISION OF COMMISSIONING SET 1

Supervision of commissioning activities of 220V DC & Float cum-Boost charger

4 SUPV.OF E&C SET 1 Supervision of E & C activities of 220V DC Float-cum-Boost charger

BOQ CUM UNPRICED PRICE SCHEDULE FOR SUPPLY OF 220V DC BATTERY CHARGER

CABLE GLANDS AND LUGS AT CHARGER AND FUSE BOX END SHALL BE IN BIDDERS SCOPE. TENTATIVE CABLE SIZE ARE MENTIONED IN DATASHEET-A. NOTE:

SL.NO. ITEM QTY. Unit Price in INR Total Price in INR Excise Duty @ on self

manufactured onlyVAT/CST @ … in INR on self

manufactured onlyFreight including

Service tax @Total FOR Site Price (Supply) in

INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess on Total Price in INR

Total Price including Service Tax in INR

Training of Engineers:

(Optional)

a) Basic cost [irrespective of no. of engineers]

b) Additional variable cost per engineer

ANNEXURE 10Training for GCB

7 1 Set

ANNEXURE-11A

Item DESCRIPTION QTY. UnitUNIT RATE ITEMS

1 Main distribution frame (MDF) 200 pairs 1 No.

2 Sub-distribution frame (SDF) 30 pairs 1 No.

3 Signal line booster unit [housed in FRP enclosure] 1 No.

4 Loud Speaker junction box 1 No.

5 Junction box (Die cast Al material) 1 No.

6 Master control station junction box 1 No.

7 Looping junction 1 No.

8 Flameproof field call station with handset 4 W cone type speaker. 1 No.

9 Flameproof field call station with handset 15 W horn type speaker. 1 No.

10 Power supply unit [48V DC] 1 No.

11 Wall/column mounted, weatherproof field call station with hand freemicrophone & speaker and built-in power amplifier

1 No.

12 Sound protecting booth 1 No.

Service tax @ including cess

on E & C in INR

Total E & C prices including Service Tax in

INR

SUPPLY (Rs)

Total Ex-Works Price duly packed in

INR/Total Price.

Unit Ex-works price/Unit Price

Excise Duty @ on self

manufactured only

1 X 500 MW FGUTPP STAGE-IV - Price Schedule Optional Items for Public Address System

Total Supply and E&C in

INR

VAT/CST @ … in INR on self manufactured

only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection &

Commissioning Charges INR

ANNEXURE-11A

Item No. DESCRIPTION QTY. Unit

TYPE TESTS

1.0 All type tests as per relevant standard shall be conducted on one piece of the following items:

1.1 Amplifier, as per IS-9302 Part-II 1 No.1.2 Microphone, as per IS-9302 Part-III 1 No.

1.3 Loudspeaker, as per IS-9302 Part-IV 1 No.

2.0 All type tests as per relevant standard shall be conducted on one piece of all solid state equipment/systems:

2.1Surge protections test

1 No.

2.2 Dry heat test as per IEC-68-2-2 1 No.

2.3 Damp heat test as per IEC-68-3 1 No.2.4 Vibration test as per IEC-68-2-6 1 No.2 5 1 N

1 X 500 MW FGUTPP STAGE-IV - Price Schedule Type Test for Public Address System[OPTIONAL]

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufactured

only

Freight including

Service tax @

TYPE TEST CHARGES

in INR

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including

cess in INR

Total Charges including

Service Tax in INR

Unit Ex-works price/Unit

Price

Total Ex-Works Price duly packed in INR/Total

Price.

2.5 Electrostatic discharge test as per IEC-801-2 or equivalent 1 No.2.6 Radio frequency immunity test as per IEC-801-6 or equivalent 1 No.2.7 Electromagnetic immunity test as per IEC-801-3 or equivalent 1 No.

NOTE:1. Bidder to indicate lump sum charges for conducting all type tests as per relevant standard on one piece.

ANNEXURE-11A

Sl No. DESCRIPTION QTY. Unit RemarksRECOMMENDED SPARES

1 Recommended spares for 3 years * ** Nos.

* Bidder to furnish the list** Bidder to furnish the quantity

Total Supply and E&C in

INR

Total Ex-Works Price duly packed in INR/Total Price.

Unit Ex-works price/Unit Price

Excise Duty including cess @ ……Rs

VAT/CST @ … in INR on self manufactured

only

1 X 500 MW FGUTPP STAGE-IV- Price Schedule Recommended Spares for Public Address System [OPTIONAL]

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection &

Commissioning Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices

including Service Tax in

INR

ANNEXURE-11A

Sl No. DESCRIPTION SUPERVISION CHARGES

1 Charges for erection supervision, testing & commissioning for complete PA system. [Instruments required for testing & commissioning shall be arranged by the bidder].

Unit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in

INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self

manufactured only

Freight including

Service tax @

1 X 500 MW FGUTPP STAGE-IV - Price Schedule supervision charges for Public Address System[OPTIONAL]

Total FOR Site Price

(Supply) in INR

Total Erection & Commissioning

Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices including Service Tax in

INR

NOTE:1. Lump sum charges quoted by the bidder shall be firm irrespective of variation in the supply BOQ of main equipment during the contract.

ANNEXURE-11A

Item No. DESCRIPTION UOM Lump sum charges (Rs)

Training of Engineers:

(Optional)

a) Basic cost [irrespective of no. of engineers]

b) Additional variable cost per engineer

1 Set

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

1 X 500 MW FGUTPP STAGE-IV - Price Schedule Training requirement for Public Address System (Optional)

Service tax @ including cess in

INR

Total Charges including Service Tax

in INR

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges INR

1

B. OPTIONAL ITEM

S.No Description Unit Qty

Unit Ex-works

price/Unit Price

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on

self manufacture

d only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including cess on E &

C in INR

Total E & C prices

including Service Tax

in INR

Total Supply and E&C in

INR

I 3.3/0.433KV Indoor Transformer 

(Dry Type)

1 2.5 MVA,3.3/0.433KV Indoor 

Transformers (Dry Type)

Nos 2

II Mandatory Spares

1 For above 3.3/0.433KV 2.5 MVA 

Transformer

1.1 HV Bushing Nos 1

1.2 LV Bushing Nos 1

1.3 LV Neutral  Nos 1

1.4 Complete Winding Limb (HV and LV) Nos 1

1.5 WTI Nos 1

1.6 Set of Thermistor / RTD with 

associated leads complete for one 

transformer

Nos 1

SL. NO.

DESCRIPTION

Unit Price

Total Ex-Works

Price duly packed in INR/Total

Price.

Excise Duty @ on self

manufactured only

Freight including

Service tax @

Total FOR Site Price

(Supply) in INR

Total Erection &

Commissioning Charges

INR

Service tax @ including cess in INR

Total Price including

Service Tax in INR

1 SHORT CIRCUIT TEST

2 NOISE LEVEL MEASUREMENT

3MEASUREMENT OF  ZERO PHASE 

SEQUENCE IMPEDANCE

4 MEASUREMENT OF THE 

HARMINICS OF NO LOAD 

CURRENT

5 TEMPERATURE RISE

6LIGHTING IMPULSE VOLTAGE 

TEST ON ALL THE THREE LIMBS 

AS PER CL. 14.1 OF IEC 60076‐3

7 DEGREE OF PROTECTION TEST 

ON MARSHALLING BOX, CABLE 

BOX AND ENCLOSURE.

i). SUPPLY ITEMS

ii). TYPE TEST FOR 2.0/2.5 MVA,3.3/0.433KV Indoor Transformers (Dry Type).

Note: Transformer shall be short circuited tested after conducting the routine tests. Rest of the type tests shall be conducted after successful short circuit testing.

Annexure‐12 (Price Schedule/BOM ofDry Type Transformer)

Bill of quantity of Erection and commissioning of Dry Type Transformers B. OPTIONAL ITEM

S.No Description Unit Qty

Unit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in

INR/Total Price.

Excise Duty including cess

@ ……Rs

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self manufactured

only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection & Commissioning Charges in INR

Service tax @ including cess

on E & C in INR

Total E & C prices including Service Tax in

INR

1 2.5 MVA,3.3/0.433 kV 

Indoor Transformers 

(Dry Type)

Nos 2

i). SUPPLY ITEMS

 1X500 MW UNCHAHAR FGTPS (UNIT‐6) RECOMMENNDED O SPARES FOR AUXILARY SERVICE TRANSFORMER(OIL FILLED)   (OPTIONAL)   ANNEXURE‐13E

RATING(A) BOARD NO.

56RECOMMENDED O & M SPARES for 

3years OperationNOS. 1 BIDDER TO FURNISH

Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in

INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in INR on self

manufactured only

Total Supply and E&C in

INRSr.No. ITEM NAME UOM TOTAL QTY.

REMARKS Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection &

Commissioning Charges INR

Service tax @ including cess

on E & C in INR

Total E & C prices

including Service Tax in

INR

PAGE 1 OF 4

123
Text Box

Sl.no. DESCRIPTION UNIT Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total

Price.

Excise Duty @ on self manufactured only

VAT/CST @ … in INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply) in INR

Total Erection & Commissioning Charges

INR

Service tax @ including cess on E & C in INR

Total E & C prices including Service Tax in

INR

Total Supply and E&C in INR

1Desktop/Wall mounted Push button operated decadic type Telephone Set

Nos

2 PVC & Jelly filled Cables Meter

Optional prices for EPABX system

DESCRIPTION UNIT QTY Unit Ex-works price/Unit Price

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @

on self manufactured only

VAT/CST @ … in

INR on self manufactured only

Freight including Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection & Commissi

oning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices including Service

Tax in INR

Total Supply

and E&C in INR

11kV, 3150A   

LENGTH  METER  50

90 deg Bend  NOS.  8

TRANSFORMER TERMINATIONS  NOS.  1

SWITCHGEAR TERMINATIONS  NOS.  1

TEE CONNECTION  NOS.  0

WALL FRAME ASSEMBLY  NOS.  1

TOTAL PRICE   

11kV, 2750A   

LENGTH  METER  130

90 deg Bend  NOS.  22

TRANSFORMER TERMINATIONS  NOS.  2

SWITCHGEAR TERMINATIONS  NOS.  5

TEE CONNECTION  NOS.  1

WALL FRAME ASSEMBLY  NOS.  2

TOTAL PRICE   

3.3kV, 3000A   

LENGTH  METER  90

90 deg Bend  NOS.  12

TRANSFORMER TERMINATIONS  NOS.  2

SWITCHGEAR TERMINATIONS  NOS.  4

WALL FRAME ASSEMBLY  NOS.  2

TOTAL PRICE   

3.3kV, 2500A   

LENGTH  METER  40

90 deg Bend  NOS.  4

TRANSFORMER TERMINATIONS  NOS.  2

SWITCHGEAR TERMINATIONS  NOS.  2

WALL FRAME ASSEMBLY  NOS.  2

TOTAL PRICE   

 Supporting structure (hot dip galvanized MS), foundation channels, hardware etc. Suitable for bus duct

elevation and length involved.

As required for

complete scope

BOQ CUM UNPRICED SCHEDULE OF 11KV & 3.3KV SEGRAGATED PHASE BUSDUCT (OPTIONAL)

ANNEXURE-1

DESCRIPTION UNIT QTY Unit Erection & Commissioning Charges in INR

Total Ex-Works Price duly packed in INR/Total Price.

Excise Duty @ on self

manufactured only

VAT/CST @ … in

INR on self manufactu

red only

Freight including

Service tax @

Total FOR Site Price (Supply)

in INR

Total Erection & Commissi

oning Charges

INR

Service tax @

including cess on E & C in INR

Total E & C prices

including Service

Tax in INR

Total Supply

and E&C in INR

11kV, 3150A   

LENGTH  METER  50

90 deg Bend  NOS.  8

TRANSFORMER TERMINATIONS  NOS.  1

SWITCHGEAR TERMINATIONS  NOS.  1

TEE CONNECTION  NOS.  0

WALL FRAME ASSEMBLY  NOS.  1

TOTAL PRICE   

11kV, 2750A   

LENGTH  METER  130

90 deg Bend  NOS.  22

TRANSFORMER TERMINATIONS  NOS.  2

SWITCHGEAR TERMINATIONS  NOS.  5

TEE CONNECTION  NOS.  1

WALL FRAME ASSEMBLY  NOS.  2

TOTAL PRICE   

3.3kV, 3000A   

LENGTH  METER  90

90 deg Bend  NOS.  12

TRANSFORMER TERMINATIONS  NOS.  2

SWITCHGEAR TERMINATIONS  NOS.  4

WALL FRAME ASSEMBLY  NOS.  2

TOTAL PRICE   

3.3kV, 2500A   

LENGTH  METER  40

90 deg Bend  NOS.  4

TRANSFORMER TERMINATIONS  NOS.  2

SWITCHGEAR TERMINATIONS  NOS.  2

WALL FRAME ASSEMBLY  NOS.  2

TOTAL PRICE   

ANNEXURE-1

BOQ for Erection & Commissioning of 11KV & 3.3KV SEGRAGATED PHASE BUSDUCT (OPTIONAL)

 Supporting structure (hot dip galvanized MS), foundation channels, hardware etc. Suitable for bus duct

elevation and length involved.

As required for

complete scope